Registrar, Sardar Patel University
Construction of Administrative Staff Quarters UNIT 02
287955
Estate/2025-26/L/9376
Open
Civil - All
Works
Anand
1 document required · 1 mandatory
₹6,000
Registrar, Sardar Patel University
₹4.9 L
23 Mar 2026
23 Mar 2026
23 Mar 2026
15 Apr 2026
23 Mar 2026
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Clearing and grubbing road land including uprooting rank vegetation grass
bushes, shrubs, sapling and trees girth up to 300 mm removal of stumps of
trees cut earlier and disposal of unserviceable materials (C) By mechanical
means in area of light jungle
Anand SOR 2024-25 Item code - 26117C Page No –
Excavation for foundation upto 1.5 m depth including sorting out and
2 stacking of useful materials and disposing off the excavated stuff upto
Meter lead.(B) Dense or Hard soil 0.00 Cu.mt 155.6 1.56 157.16
Anand SOR 2024-25 Item code - 04001B Page No –
Excavation for foundation for depth from 1.5 m to 3.0 m including sorting
3 out and stacking of useful materials and disposing off the excavated stuff
upto 50 Meter lead.(B) Dense or Hard soil 0.00 Cu.mt 168.81 1.69 170.50
Anand SOR 2024-25 Item code - 04002B Page No –
Excavation for foundation for depth from 3 m to 5 m including sorting out
4 and stacking of useful materials and disposing off the excavated stuff upto
Meter lead.(B) Dense or Hard soil 0.00 Cu.mt 181.13 1.81 182.94
Anand SOR 2024-25 Item code - 04003B Page No –
Providing and laying cement concrete 1:4:8 (1- Cement : 4- coarse sand : 8-
5 hand broken stone aggregates 40 mm nominal size) and curing complete
excluding cost of formwork in (A) Foundation and Plinth (upto 10 ton)
Anand SOR 2024-25 Item code - 5004A Page No –
PILE FOUNDATION
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles) and getting out
6 the soil and disposal of the surplus excavated soil as directed within a lead of
50 Meter for following diameter of pipes.(iii) 300 mm
Anand SOR 2024-25 Item code - 04010C Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Boring holes 3.5 m deep in ordinary soil (for cast in situ piles) and getting out
the soil and disposal of the surplus excavated soil as directed within a lead of
50 Meter for following diameter of pipes.(iii) 300 mm Extra for under
reaming inside the bor 0.00 Nos 657.49 6.57 664.06
Anand SOR 2024-25 Item code - 04011C Page No –
ANTI TERMITE TREATMENT
Applying general insecticide pest control treatment to floors, cupboards etc
including labour material etc. complete. Using Heptachloride 20 EC. As Per
6113_pests Consentration Weight 0.50 percent is recommended one litre
chemical emulsion dillute with 39 liter of water will give. Total dillute
concrentration will be 40 litre inclusive of one litre chemical emulsion
appication 0.5 Litre chemical / Sqm of surface is recommended as per I.S
Anand SOR 2024-25 Item code - 22006 Page No –
9 RCC FOUNDATION
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, excluding the cost of centering shuttering , finishing and cost of
reinforcement including the cost of admixture in recommended proportion
as per I.S : 9103to accelarate / retard setting of concrete improve workability
with out impairing strength and durability as per direction of engineerin-
charge without flash in R.C.C. M 250 work with all lead and lift . (Minimum
cement level as per IS 456 shall be maintained) minimum cement level
should be 380kg/cum. Footing
Anand SOR 2024-25 Item code - 5056 Page No – 80 + basic rate of RMC
Received from indiamart
PILE CONCRETING
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, excluding the cost of centering shuttering , finishing and cost of
reinforcement including the cost of admixture in recommended proportion
as per I.S : 9103to accelarate / retard setting of concrete improve workability
with out impairing strength and durability as per direction of engineerin-
charge without flash in R.C.C. M 250 work with all lead and lift . (Minimum
cement level as per IS 456 shall be maintained) minimum cement level
should be 380kg/cum. Pile concreting
Anand SOR 2024-25 Item code - 5056 Page No – 80 + basic rate of RMC
Received from indiamart
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
11 RCC WORK Ground Beam
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Ground beam
As per rate analysis
12 RCC Ground Floor Beam
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Ground floor beam
As per rate analysis
13 RCC First Floor Beam
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. First floor beam
As per rate analysis
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
14 RCC 2 Floor Beam
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Second floor beam
As per rate analysis
15 RCC 3rd Floor Beam
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Third floor beam
As per rate analysis
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
16 RCC 4 Floor Beam
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Fourth floor beam
As per rate analysis
17 RCC 5th Floor Beam
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Fifth floor beam
As per rate analysis
18 RCC Terrace Floor Beam
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Terrace floor beam
As per rate analysis
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
19 RCC For Grade slab
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Grade slab
As per rate analysis
20 RCC For Ground Floor slab
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Ground floor slab and landing
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
As per rate analysis
21 RCC First Floor slab
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. First floor slab and landing
As per rate analysis
22 RCC 2nd Floor slab
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Second floor slab and landing
As per rate analysis
23 RCC 3rd Floor slab
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Third floor slab and landing
As per rate analysis
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
24 RCC 4 Floor slab
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Fourth floor slab and landing
As per rate analysis
25 RCC 5th Floor slab
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Fifth floor slab and landing
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
As per rate analysis
26 RCC Terrace Floor slab
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Terrace floor slab and landing
As per rate analysis
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. First floor loft
As per rate analysis
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Second floor loft
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
As per rate analysis
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Third floor loft
As per rate analysis
30 FORTH Floor Loft
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Fourth floor loft
As per rate analysis
31 FIFTH Floor Loft
Providing & laying in position READY MIXED M-250 grade concrete without
flyash For reinforced cement concrete work using cement content as per
approved design mix manufactured in fully automatic batching plant and
transported to site of work in transit mixer for a lead up to 20 kms having
continuous agitated mixer, manufactured as per mixed design of specified
grade for reinforced cement
concrete work including pumping of RMC at all Heights. from transit mixer to
site of laying, including the cost of centering shuttering , finishing but
excluding the cost of reinforcement. including the cost of admixture in
recommended proportion as per I.S : 9103to accelarate / retard setting of
concrete improve workability with out impairing strength and durability as
per direction of engineerin- charge without flash in R.C.C. M 250 work with
all lead and lift . (Minimum cement level as per IS 456 shall be maintained)
minimum cement level should be 380kg/cum. Fifth floor loft
As per rate analysis
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
32 RCC water tank
Providing and laying in position Ready Mixed M-350 grade concrete for
reinforced cement conctere work , using cement content as per approved
Design Mix manufactured in fully automatic batching plant and transported
to site of work in transit mixer for a lead up to 20 kms having continuous
agitated mixer, manufactured as per mix design of specified grade for
reinforced cement concrete work including pumping of R.M.C. from transit
mixer to site of laying, including the cost of centering shuttering finishing and
excluding reinforcement, including cost of admixtures in recommended
proportions as per IS: 9103 to accelerate/ retard setting of concrete, improve
workability without impairing strength and durability as per direction of the
Engineer - in - charge. Without Fly Ash(Min cement level as per latest IS
shall be maintained) (Cement level 425 kg ) For Water Tank
As per rate analysis
Providing formwork of ordinary timber planking so as to give a rough finish
including centering shuttering strutting and propping etc. Height of propping
and centering below supporting floor to ceiling not exceeding 4 M. and
removal of the same for in situ reinforced concrete and plain concrete work
in. (A) Foundations Footings Bases of Columns etc. and Mass concrete. (upto
Anand SOR 2024-25 Item code - 09001A Page No –
Providing formwork of ordinary timber planking so as to give a rough finish
including centering shuttering strutting and propping etc. height of propping
and centering below supporting floor to ceiling not exceeding 4 M. and
removal of the same for in situ reinforced concrete and plain concrete work
in. (M) Staircase with sloping or stepped soffits including risers and stringers
excluding landing. (upto 10 ton)
Anand SOR 2024-25 Item code - 09001M Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing formwork of ordinary timber planking so as to give a rough finish
including centering shuttering strutting and propping etc. height of propping
and centering below supporting floor to ceiling not exceeding 4 M. and
removal of the same for in situ reinforced concrete and plain concrete work
in. (C) Vertical surface such as walls (any thickness) partitions and the like
including attached buttresses & string course & the like. (upto 10 ton)
Anand SOR 2024-25 Item code - 09001C Page No –
Providing and laying cement concrete 1:1.5:3 (1- Cement : 1.5- Coarse sand :
36 3- crushed stone aggregates 20 mm nominal size) and curing complete
including cost of formwork in (A) Wall Caps / Coping (upto 10 ton)
As per rate analysis
Providing and laying controlled cement concrete M.250
exposed work with curing etc. complete including the
cost of formwork but excluding the cost of reinforcement
for R.C.C. work in (B) COLUMNS:(ii) Having
cross-sectional area more than 0.08 Sq.M and upto 0.12 Sq.m for ground
Anand SOR 2024-25 Item code - 05034B2 Page No –
Providing and laying controlled cement concrete M.250
exposed work with curing etc. complete including the
38 cost of formwork but excluding the cost of reinforcement
for R.C.C. work in (B) COLUMNS:(ii) Having
cross-sectional area more than 0.08 Sq.M and upto 0.12 Sq.m for first floor
Anand SOR 2024-25 Item code - 05034B2, 5015A Page No -78 &
Providing and laying controlled cement concrete M.250
exposed work with curing etc. complete including the
cost of formwork but excluding the cost of reinforcement
for R.C.C. work in (B) COLUMNS:(ii) Having
cross-sectional area more than 0.08 Sq.M and upto 0.12 Sq.m for second
Anand SOR 2024-25 Item code - 05034B2, 5015 Page No - 80 &
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying controlled cement concrete M.250
exposed work with curing etc. complete including the
40 cost of formwork but excluding the cost of reinforcement
for R.C.C. work in (B) COLUMNS:(ii) Having
cross-sectional area more than 0.08 Sq.M and upto 0.12sq.m for third floor
Anand SOR 2024-25 Item code - 05034B2, 5015 Page No -80 &
Providing and laying controlled cement concrete M.250
exposed work with curing etc. complete including the
41 cost of formwork but excluding the cost of reinforcement
for R.C.C. work in (B) COLUMNS:(ii) Having
cross-sectional area more than 0.08 Sq.M and upto 0.12Sq.m forth floor
Anand SOR 2024-25 Item code - 05034B2, 5015 Page No -78 &
Providing and laying controlled cement concrete M.250
exposed work with curing etc. complete including the
42 cost of formwork but excluding the cost of reinforcement
for R.C.C. work in (B) COLUMNS:(ii) Having
cross-sectional area more than 0.08 Sq.M and upto 0.12Sq.m for fifth floor
Anand SOR 2024-25 Item code - 05034B2, 5015 Page No - 78 &
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Columns : Having cross sectional area more
than 0.12 Sq.mt and upto 0.18 Sq.mt. upto G.L & Ground floor
Anand SOR 2024-25 Item code - 05034B3 Page No -
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Columns : Having cross sectional area more
than 0.12 Sq.mt and upto 0.18 Sq.mt First floor level
Anand SOR 2024-25 Item code - 05034B3, 5015 Page No - 78 &
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Columns : Having cross sectional area more
than 0.12 Sq.mt and upto 0.18 Sq.mt Second floor level
Anand SOR 2024-25 Item code - 05034B3, 5015 Page No - 78 &
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Columns : Having cross sectional area more
than 0.12 Sq.mt and upto 0.18 Sq.mt Third floor level
Anand SOR 2015-16 Item code - 05034B3, 5015 Page No – 78 &
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Columns : Having cross sectional area more
than 0.12 Sq.mt and upto 0.18 Sq.mt Fourth floor level
Anand SOR 2015-16 Item code - 05034B3, 5015 Page No - 78 &
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Columns : Having cross sectional area more
than 0.12 Sq.mt and upto 0.18 Sq.mt Fifth floor level
Anand SOR 2024-25 Item code - 05034B3, 5015 Page No - 78 &
Providing and laying controlled cement concrete M.250 and curing complete
including the cost of formwork but excluding the cost of reinforcement for
reinforced concrete work in (B) Columns : Having cross sectional area more
than 0.12 Sq.mt and upto 0.18 Sq.mt Terrace floor level
Anand SOR 2024-25 Item code - 05034B3, 5015 Page No -78 &
Providing and laying controlled cement concrete M.200 for curing complete
50 excluding cost of formwork and reinforcement for reinforced concrete work
in (E) Staircases excluding landing upto floor two level (upto 10 ton)
Anand SOR 2024-25 Item code - 05024E Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying controlled cement concrete M.200 for curing complete
excluding cost of formwork and reinforcement for reinforced concrete work
in (E) Staircases excluding landing upto floor two level (upto 10 ton) First
floor level 3.40 cumt 5624.71 56.25 5680.96
Anand SOR 2024-25 Item code - 05024E Page No –71
Providing and laying controlled cement concrete M.200 for curing complete
excluding cost of formwork and reinforcement for reinforced concrete work
in (E) Staircases excluding landing upto floor two level (upto 10 ton) Second
floor level 3.40 cumt 5665.42 56.65 5722.07
Anand SOR 2024-25 Item code - 05024E Page No –71
Providing and laying controlled cement concrete M.200 for curing complete
excluding cost of formwork and reinforcement for reinforced concrete work
in (E) Staircases excluding landing upto floor two level (upto 10 ton) Third
floor level 3.40 cumt 5706.13 57.06 5763.19
Anand SOR 2024-25 Item code - 05024E Page No –
Providing and laying controlled cement concrete M.200 for curing complete
excluding cost of formwork and reinforcement for reinforced concrete work
in (E) Staircases excluding landing upto floor two level (upto 10 ton) Fourth
floor level 0.00 cumt 5746.84 57.47 5804.31
Anand SOR 2024-25 Item code - 05024E Page No –
Providing and laying controlled cement concrete M.200 for curing complete
excluding cost of formwork and reinforcement for reinforced concrete work
in (E) Staircases excluding landing upto floor two level (upto 10 ton) Fifth
floor level 0.00 cumt 5787.55 57.88 5845.43
Anand SOR 2015-16 Item code - 05024E Page No –
Providing and laying controlled cement concrete M.200 for curing complete
excluding cost of formwork and reinforcement for reinforced concrete work
in (E) Staircases excluding landing upto floor two level (upto 10 ton) Terrace
Anand SOR 2024-25 Item code - 05024E Page No -
Providing and laying controlled cement concrete M.200 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two level. (upto 10 ton)
Ground floor level. Lift wall 4.14 cumt 4792.64 47.93 4840.57
Anand SOR 2024-25 Item code - 05024K, Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying controlled cement concrete M.200 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two level. (upto 10 ton) First
floor level) Lift wall 2.59 cumt 4833.35 48.33 4881.68
Anand SOR 2024-25 Item code - 05024K, Page No –
Providing and laying controlled cement concrete M.200 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two level. (upto 10 ton) .
Second floor level. Lift wall 2.59 cumt 4874.06 48.74 4922.80
Anand SOR 2024-25 Item code - 05024K, Page No -71
Providing and laying controlled cement concrete M.200 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two level. (upto 10 ton)
Third floor level Lift wall 2.59 cumt 4914.77 49.15 4963.92
Anand SOR 2024-25 Item code - 05024K, Page No -
Providing and laying controlled cement concrete M.200 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two level. (upto 10 ton)
Fourth floor level Lift wall 0.00 cumt 4955.48 49.55 5005.03
Anand SOR 2024-25 Item code - 05024K, Page No –71
Providing and laying controlled cement concrete M.200 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two level. (upto 10 ton)
Fifth floor level Lift wall 0.00 cumt 4996.19 49.96 5046.15
Anand SOR 2024-25 Item code - 05024K, Page No -
Providing and laying controlled cement concrete M.200 and curing complete
excluding the cost of formwork and reinforcement for reinforced concrete
work in (K) Vertical and Horizontial its upto floor two level. (upto 10 ton)
Terrace floor level Lift wall 2.59 Cu.mt 5036.90 50.37 5087.27
Anand SOR 2024-25 Item code - 05024K, Page No -72,
Providing and laying controlled cement concrete M.200 and curing complete
including the cost of new ply formwork and excluding reinforcement for
reinforced concrete work in (C) Lintels upto floor two level. (upto 10 ton)
Anand SOR 2024-25 Item code - 05024C Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying controlled cement concrete M.200 and curing complete
65 including the cost of new ply formwork and excluding reinforcement for
reinforced concrete work in (C) Lintels (upto 10 ton) First floor
Anand SOR 2024-25 Item code - 05024C Page No –
Providing and laying controlled cement concrete M.200 and curing complete
66 including the cost of new ply formwork and excluding reinforcement for
reinforced concrete work in (C) Lintels (upto 10 ton) Second floor
Anand SOR 2024-25 Item code - 05024C Page No –
Providing and laying controlled cement concrete M.200 and curing complete
67 including the cost of new ply formwork and excluding reinforcement for
reinforced concrete work in (C) Lintels (upto 10 ton) Third floor
Anand SOR 2024-25 Item code - 05024C Page No –
Providing and laying controlled cement concrete M.200 and curing complete
68 including the cost of new ply formwork and excluding reinforcement for
reinforced concrete work in (C) Lintels (upto 10 ton) Fourth floor
Anand SOR 2024-25 Item code - 05024C Page No –71
Providing and laying controlled cement concrete M.200 and curing complete
69 including the cost of new ply formwork and excluding reinforcement for
reinforced concrete work in (C) Lintels (upto 10 ton) Fifth floor
Anand SOR 2024-25 Item code - 05024C Page No –
Providing and laying controlled cement concrete M.200 and curing complete
70 including the cost of new ply formwork and excluding reinforcement for
reinforced concrete work in (C) Lintels (upto 10 ton)Terrace floor
Anand SOR 2024-25 Item code - 05024C Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying ordinery cement concrete 1:1.5:3 (1- Cement : 1.5-
Coarse sand : 3- graded stone aggregates 20 mm nominal size) for reinforced
concrete Chhajjas exceeding 10cm. thickness above floor two level including
finishing the exposed surfaces with cement mortar 1:3 (1-cement, 3 Fine
sand) to give a smooth and even surface centering and formwork and curing
complete excluding cost of reinforcement. First floor
As per rate analysis 05012A page 68 +1.5*300 ( cement )
Providing and laying ordinery cement concrete 1:1.5:3 (1- Cement : 1.5-
Coarse sand : 3- graded stone aggregates 20 mm nominal size) for reinforced
concrete Chhajjas exceeding 10cm. thickness above floor two level including
finishing the exposed surfaces with cement mortar 1:3 (1-cement, 3 Fine
sand) to give a smooth and even surface centering and formwork and curing
complete excluding cost of reinforcement. First floor
As per rate analysis & Anand SOR 2024-25 Item code - 5015 Page No –68
Providing and laying ordinery cement concrete 1:1.5:3 (1- Cement : 1.5-
Coarse sand : 3- graded stone aggregates 20 mm nominal size) for reinforced
concrete Chhajjas exceeding 10cm. thickness including finishing the exposed
surfaces with cement mortar 1:3 (1-cement, 3 Fine sand) to give a smooth
and even surface centering and formwork and curing complete excluding
cost of reinforcement. Second floor
As per rate analysis & Anand SOR 2024-25 Item code - 5015 Page No –68
Providing and laying ordinery cement concrete 1:1.5:3 (1- Cement : 1.5-
Coarse sand : 3- graded stone aggregates 20 mm nominal size) for reinforced
concrete Chhajjas exceeding 10cm. thickness including finishing the exposed
surfaces with cement mortar 1:3 (1-cement, 3 Fine sand) to give a smooth
and even surface centering and formwork and curing complete excluding
cost of reinforcement. Third floor
As per rate analysis & Anand SOR 2024-25 Item code - 5015 Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying ordinery cement concrete 1:1.5:3 (1- Cement : 1.5-
Coarse sand : 3- graded stone aggregates 20 mm nominal size) for reinforced
concrete Chhajjas exceeding 10cm. thickness including finishing the exposed
surfaces with cement mortar 1:3 (1-cement, 3 Fine sand) to give a smooth
and even surface centering and formwork and curing complete excluding
cost of reinforcement. Fourth floor
As per rate analysis & Anand SOR 2024-25 Item code - 5015 Page No –
Providing and laying ordinery cement concrete 1:1.5:3 (1- Cement : 1.5-
Coarse sand : 3- graded stone aggregates 20 mm nominal size) for reinforced
concrete Chhajjas exceeding 10cm. thickness including finishing the exposed
surfaces with cement mortar 1:3 (1-cement, 3 Fine sand) to give a smooth
and even surface centering and formwork and curing complete excluding
cost of reinforcement. Fifth floor
As per rate analysis & Anand SOR 2024-25 Item code - 5015 Page No –
Providing and laying ordinery cement concrete 1:1.5:3 (1- Cement : 1.5-
Coarse sand : 3- graded stone aggregates 20 mm nominal size) for reinforced
concrete Chhajjas exceeding 10cm. thickness including finishing the exposed
surfaces with cement mortar 1:3 (1-cement, 3 Fine sand) to give a smooth
and even surface centering and formwork and curing complete excluding
cost of reinforcement. Terrace floor
As per rate analysis & Anand SOR 2024-25 Item code - 5015 Page No –
REINFORCMENT QUANTITY
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including
78 bending, binding and placing in position complete upto floor two level (upto
Anand SOR 2024-25 Item code - 05014C Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and applying Anti Corossive Rebar Coating Chemical on existing
exposed TMT Bar FE 500/500D reinforcement for R.C.C. work including
78 A procurement of Branded and aproved quality of antirust paint , applying on
exposed reinforcement in 2 coats of including scratching and removing rust
from existing exposed reinforcement (upto 10 ton)
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including
79 bending, binding and placing in position complete For First floor level. (upto
Anand SOR 2024-25 Item code - 05014C, 5016 Page No –
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including
80 bending, binding and placing in position complete For Second floor level.
Anand SOR 2024-25 Item code - 05014C, 5016 Page No –68
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including
81 bending, binding and placing in position complete For Third floor level. (upto
Anand SOR 2024-25 Item code - 05014C, 5016 Page No –
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including
82 bending, binding and placing in position complete For Fourth floor level.
Anand SOR 2024-25 Item code - 05014C, 5016 Page No –
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including
83 bending, binding and placing in position complete For Fifth floor level. (upto
Anand SOR 2024-25 Item code - 05014C, 5016 Page No –
Providing TMT Bar FE 500/500D reinforcement for R.C.C. work including
84 bending, binding and placing in position complete For Terrace floor level.
Anand SOR 2024-25 Item code - 05014C, 5016 Page No –
Providing and applying anti-corrosive treatment with polymer base materials
to the steel reinforcement including descaling the dust and applying the
preventive coating of approved make (for the R.C.C. structures near coastal
area only) etc complete. 7.50 MT 4127.68 41.28 4168.96
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Anand SOR 2024-25 Item code -05035 Page No –
FILLING QUANTITY
Filling available excavated earth (excluding rock) in trenches. plinth, sides of
85 foundations etc. in layers not exceeding 20 cm. in depth consolidating each
disposited layer by ramming and watering.
Anand SOR 2024-25 Item code - 04006 Page No –
Filling in foundation and plinth with murrum or selected soil in layers of
86 20cm. thickness including watering, ramming and consolidating etc.
complete. (upto 10 ton) 0.00 Cu.mt 291.47 2.91 294.38
Anand SOR 2024-25 Item code - 04008A Page No –
Providing and fixing chicken mesh of 22 gauge, with about 30 cm. width at
the junction of R.C.C members and brick work, of approved quality including
fixing mesh in position by necessary drilling in concrete or/B.B.masonry and
or tying by binding wire etc. complete.
Anand SOR 2024-25 Item code -M152 Page No –
Brick work using common burnt clay building bricks having crushing strength
88 not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
Cement : 5 - fine sand)(B) Conventional (upto 10 ton) (B) Conventional.
Anand SOR 2024-25 Item code - 06001B Page No –
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
89 Cement : 5 - fine sand)(B) Conventional (upto 10 ton) Extra for brick work in
superstructure above plinth level upto floor two level (B) Conventional.
Ground floor 59.86 Cu.mt 4481.99 44.82 4526.81
Anand SOR 2024-25 Item code - 06001B, 06006B Page No - 84 &
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
Cement : 5 -fine sand)(B) Conventional (upto 10 ton) Extra for brick work in
superstructure above floor two level (B) Conventional. First floor
Anand SOR 2024-25 Item code - 06001B, 06006B, 06007A2 Page No -84 &
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
Cement : 5 -fine sand)(B) Conventional (upto 10 ton) Extra for brick work in
superstructure above floor two level (B) Conventional. Second floor
Anand SOR 2024-25 Item code - 06001B, 06006B, 06007A2 Page No - 84 &
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
Cement : 5 -fine sand)(B) Conventional (upto 10 ton) Extra for brick work in
superstructure above floor two level (B) Conventional.Third floor
Anand SOR 2024-25 Item code - 06001B, 06006B, 06007A2 Page No -84 &
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
Cement : 5 -fine sand)(B) Conventional (upto 10 ton) Extra for brick work in
superstructure above floor two level (B) Conventional. Fourth floor
Anand SOR 2024-25 Item code - 06001B, 06006B, 06007A2 Page No -84 &
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
Cement : 5 -fine sand)(B) Conventional (upto 10 ton) Extra for brick work in
superstructure above floor two level (B) Conventional. Fifth floor
Anand SOR 2015-16 Item code - 06001B, 06006B, 06007A2 Page No - 84 &
Brick work using common burnt clay building bricks having crushing strength
not less than 35 kg./Sq.Cm. in foundation and plinth in Cement Mortar 1:5 (1-
Cement : 5 -fine sand)(B) Conventional (upto 10 ton) Extra for brick work in
superstructure above floor two level (B) Conventional. Terrace floor
Anand SOR 2024-25 Item code - 06001B, 06006B, 06007A2 Page No -84 &
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
(i) Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
96 coarse sand ) in foundation and plinth. Extra for half brick masonry in
superstructure above plinth level upto floor two level. (B) Conventional (upto
10 ton) Ground floor 25.47 Sq.mt 623.6 6.24 629.84
Anand SOR 2024-25 Item code - 06008A2 Page No –
(i) Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
97 coarse sand ) in foundation and plinth. Extra for half brick masonry in
superstructure above floor two level. (B) Conventional (upto 10 ton) First
Anand SOR 2024-25 Item code - 06008A2, 06010B Page No - 86 &
(i) Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
98 coarse sand ) in foundation and plinth. Extra for half brick masonry in
superstructure above floor two level. (B) Conventional (upto 10 ton) Second
Anand SOR 2024-25 Item code - 06008A2, 06010B Page No -86 &
(i) Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
99 coarse sand ) in foundation and plinth. Extra for half brick masonry in
superstructure above floor two level. (B) Conventional (upto 10 ton) Third
Anand SOR 2015-16 Item code - 06008A2, 06010B & 06011B Page No - 86 &
(i) Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
100 coarse sand ) in foundation and plinth. Extra for half brick masonry in
superstructure above floor two level. (B) Conventional (upto 10 ton) Fourth
Anand SOR 2024-25 Item code - 06008A2, 06010B Page No - 86 &
(i) Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
101 coarse sand ) in foundation and plinth. Extra for half brick masonry in
superstructure above floor two level. (B) Conventional (upto 10 ton) Fifth
Anand SOR 2024-25 Item code - 06008A2, 06010B Page No - 86 &
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
(i) Half brick masonry in common brunt clay building bricks having crushing
strength not less than 35 Kg/Sq.Cm. in Cement mortar 1:4 (1- Cement : 4 -
102 coarse sand ) in foundation and plinth. Extra for half brick masonry in
superstructure above floor two level. (B) Conventional (upto 10 ton)
Staircabin 37.09 Sq.mt 971.9 9.72 981.62
Anand SOR 2024-25 Item code - 06008A2, 06010B Page No - 86 &
providing supplying and laying dry charcol having dry density not more then
250kg/cum including lift up to 5th floor slab etc comp 23.11 Cu.mt 7500 75.00 7575.00
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering upto floor two level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Ground floor ( common toilet)
Anand SOR 2024-25 Item code - 17001A, 17004 Page No –
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering above floor two level and finished even and smooth in
& finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) First floor (W.C &Bath)
Anand SOR 2024-25 Item code - 17001A, 17004, 17007A Page No –
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for third level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Second floor (W.C &Bath)
Anand SOR 2024-25 Item code - 17001A, 17004, 17007A Page No –
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for fourth level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Third floor (W.C &Bath)
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Anand SOR 2024-25 Item code - 17001A, 17004, 17007A Page No –
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for fifth level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Fourth floor (W.C &Bath)
Anand SOR 2024-25 Item code - 17001A, 17004, 17007A Page No –
Providing 10mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for sixth level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Fifth floor (W.C &Bath)
Anand SOR 2024-25 Item code - 17001A, 17004, 17007A Page No –
Providing 15mm thick cement plaster in single coat on brick/concrete walls
for interior plastering upto floor two level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Ground floor
Anand SOR 2024-25 Item code - 17002A, 17004 Page No –
Providing 15mm thick cement plaster in single coat on brick/concrete walls
for interior plastering above floor two level and finished even and smooth in
& finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) First floor
Anand SOR 2024-25 Item code - 17002A, 17004, 17007A Page No –
Providing 15mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for third level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Second floor 1329.05 Sq.mt 299.2 2.99 302.19
Anand SOR 2024-25 Item code - 17002A, 17004 Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing 15mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for fourth level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Third floor 1329.05 Sq.mt 322.86 3.23 326.09
Anand SOR 2024-25 Item code - 17002A, 17004 Page No –
Providing 15mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for fifth level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Fourth floor 0.00 Sq.mt 346.52 3.47 349.99
Anand SOR 2024-25 Item code - 17002A, 17004 Page No –
Providing 15mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for sixth level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Fifth floor 9.87 Sq.mt 370.18 3.70 373.88
Anand SOR 2024-25 Item code - 17002A, 17004 Page No –
Providing 15mm thick cement plaster in single coat on brick/concrete walls
for interior plastering for seventh level and finished even and smooth in &
finishing with a floating coat of neat cement slurry (i)Cement mortar 1:3 (1-
cement:3-sand) Staircabin 138.46 Sq.mt 393.84 3.94 397.78
Anand SOR 2024-25 Item code - 17002A, 17004 Page No –
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering upto floor two level and
finished even and smooth in (i) Cement mortar 1:3 (1-cement:3-sand)
finishing with a floating coat of neat cement slurry. (upto 10 ton) for
plastering on ceilings and sofits of stairs upto floor two level instead of
plastering on walls. Ground floor ceiling & landing
Anand SOR 2024-25 Item code - 17002A, 17004, 17006, Page No –
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering above floor two level for every
additional storey height and finished even and smooth in (i) Cement mortar
117 1:3 (1-cement:3-sand) finishing with a floating coat of neat cement slurry.
(upto 10 ton) for plastering on ceilings and sofits of stairs above floor two
level for every additional storey height instead of plastering on walls. First
floor ceiling & landing
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Anand SOR 2024-25 Item code - 17002A, 17004, 17006, Page No –
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering above floor two level for every
additional storey height and finished even and smooth in (i) Cement mortar
118 1:3 (1-cement:3-sand) finishing with a floating coat of neat cement slurry.
(upto 10 ton) for plastering on ceilings and sofits of stairs above floor two
level for every additional storey height instead of plastering on walls. Second
floor ceiling & landing
Anand SOR 2024-25 Item code - 17002A, 17004, 17006, Page No –
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering above floor two level for every
additional story height and finished even and smooth in (i) Cement mortar
119 1:3 (1-cement:3-sand) finishing with a floating coat of neat cement slurry.
(upto 10 ton) for plastering on ceilings and sofits of stairs above floor two
level for every additional story height instead of plastering on walls. Third
floor ceiling & landing
Anand SOR 2015-16 Item code - 17002A, 17004, 17006, 17008 Page No -
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering above floor two level for every
additional storey height and finished even and smooth in (i) Cement mortar
120 1:3 (1-cement:3-sand) finishing with a floating coat of neat cement slurry.
(upto 10 ton) for plastering on ceilings and sofits of stairs above floor two
level for every additional storey height instead of plastering on walls. Fourth
floor ceiling & landing
Anand SOR 2024-25 Item code - 17002A, 17004, 17006, Page No -143,144
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering above floor two level for every
additional storey height and finished even and smooth in (i) Cement mortar
121 1:3 (1-cement:3-sand) finishing with a floating coat of neat cement slurry.
(upto 10 ton) for plastering on ceilings and sofits of stairs above floor two
level for every additional storey height instead of plastering on walls. Fifth
floor ceiling & landing
Anand SOR 2015-16 Item code - 17002A, 17004, 17006, 17008 Page No -141
Providing 15mm thick cement plaster in single coat on Rough (Similar)side of
single or half brick walls for interior plastering above floor two level for every
additional storey height and finished even and smooth in (i) Cement mortar
122 1:3 (1-cement:3-sand) finishing with a floating coat of neat cement slurry.
(upto 10 ton) for plastering on ceilings and sofits of stairs above floor two
level for every additional storey height instead of plastering on walls.
Anand SOR 2024-25 Item code - 17002A, 17004, 17006, Page No -143,144
20 mm. thick outside sand faced cement plaster on wall upto height
metres above ground level consisting of 12mm thick backing coat of c.m. 1 :
3 (1 cement : 3 sand) and 8 mm thick finishing coat with butki plaster of c.m.
1 : 1 (1 cement : 1 sand) etc. complete
Anand SOR 2024-25 Item code - 17009 Page No –
20 mm. thick outside sand faced cement plaster on wall upto height
metres above ground level consisting of 12mm thick backing coat of c.m. 1 :
3 (1 cement : 3 sand) and 8 mm thick finishing coat of c.m. 1 : 1 (1 cement :
sand) etc. height more than 10metres from ground level for every additional
height of 5 metres of part there of. complete (10 to 15mt) including 25mm
thk groove at slab level .butki plaster
Anand SOR 2024-25 Item code - 17009 & 17014 Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
20 mm. thick outside sand faced cement plaster on wall upto height
metres above ground level consisting of 12mm thick backing coat of c.m. 1 :
3 (1 cement : 3 sand) and 8 mm thick finishing coat of c.m. 1 : 1 (1 cement :
sand) etc. height more than 10metres from ground level for every additional
height of 5 metres of part there of. complete (15 to 20mt) including 25mm
thk groove at slab level. butki plaster
Anand SOR 2024-25 Item code - 17009 & 17014 Page No –
20 mm. thick outside sand faced cement plaster on wall upto height
metres above ground level consisting of 12mm thick backing coat of c.m. 1 :
3 (1 cement : 3 sand) and 8 mm thick finishing coat of c.m. 1 : 1 (1 cement :
sand) etc. height more than 10metres from ground level for every additional
height of 5 metres of part there of. complete (20 to 25mt) including 25mm
thk groove at slab level,butki plaster
Anand SOR 2024-25 Item code - 17009 & 17014 Page No –
Applying two coats of putty & two coats of primer of
approved brand and manufacture on new wall surface to
127 give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign
matter and sand papered smooth 1663.15 Sq.mt 40.19 0.40 40.59
Anand SOR 2024-25 Item code - 19032 Page No –
Finishing wall with weather proof exterior emulsion paint on wall surface
(two coats) to give an required shape even shade after thoroughly brushing
the surface to remove all dirt, and remains of loose powdered materials.etc
Anand SOR 2024-25 Item code - 19031 Page No –
Applying two coats of Birla or Asian acrylic lapy ( putty) & two coats of
primer of approved brand and manufacture on new wall surface to give an
even shade including thoroughly brushing the surface free from mortar
dropping and other foreign matter and sand papered smooth.
Anand SOR 2024-25 Item code - 19032 Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Preoviding and applying (Two coats) with tracrtor emulsion paint with
alkaline resistance primer of approved brand and manufacture and of
required shade on wall surfaces to give an even shade, over and including a
130 priming coat with primer of approved brand and manufacture after
thoroughly brushing the surface free from mortar dropping and other
foreign matter and also including preparing the surface even and sand
papered smooth.
As Per Market rate
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on
existing flooring by adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including finised with flush
pointing & cleaning the surface etc. complete for antiskit(LIGHT shade) as per
architectural design (upto 10 ton)
Anand SOR 2024-25 Item code - 14021, Page No –
P & L 24" x 24" vitrified 8 mm thick tile flooring over 20mm (average) base of
cement mortar 1:6 ( 1 cement: 6 coarse sand) on new surface or fixing on
existing flooring by adhesive material including dismentaling of existing
flooring and jointed with color cement slurry including finised with flush
pointing & cleaning the surface etc. complete for antiskit (Dark shade) as per
architectural design (upto 10 ton)
Anand SOR 2024-25 Item code - 14021, Page No –
Providing and laying mat finished Ceramic tiles 6mm thick in flooring treads
of steps and landing laid on a bed of 12mm thick cement mortar 1:3 (1-
cement : 3-coarse sand ) finishing with flush pointing in white cement. (upto
10 ton) 300 x 600mm tiles size 107.40 Sq.mt 987.29 0.67 987.96
Anand SOR 2024-25 Item code - 14008B, Page No –
Providing and laying mat finished Ceramic tiles 6mm thick in skrting risers of
134 steps and dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand)
and jointed with white cement slurry (upto 10 ton) 300 x 600mm tiles size
Anand SOR 2024-25 Item code - 14009B, Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying Granite in treads and riser of steps and landing laid on
135 a bed of 12mm thick cement mortar 1:3 (1-cement : 3-coarse sand ) finishing
with flush pointing in white cement. (upto 10 ton)
Providing and laying Greanite in skirting, facing of steps, risers of steps and
136 dedo on 10mm thick cement plaster 1:3 (1-cement : 3-coarse sand) and
jointed with white cement slurry (upto 10 ton) 26.81 Sq.mt 973.00 9.73 982.73
Providing and laying polished Kota stone slab flooring over 20mm (Average)
thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 (1-
137 Lime putty :1.5 - coarse sand) laid over and jointed with grey cement slurry
mixed with pigment to match the shade of slab including rubbing and
polishing etc. complete. (A) 25mm thick (upto 10 ton)
Anand SOR 2024-25 Item code - 14012AA, Page No –
Providing and laying polished Kota stone slab flooring over 20mm (Average)
thick base of cement mortar 1:6 (1-cement : 6-coarse sand) or L.M. 1.1.5 laid
over and jointed with grey cement slurry including rubbing and polishing etc.
complete. (B) 30 mm thick (upto 10 ton)
Anand SOR 2024-25 Item code - 14012BA, Page No –
Providing and laying polished kota stone slab 25mm thick in risers of
steps,skirting Dedo and pillars laid on 10mm thick cement mortar 1:3 (1-
139 Cement : 3 coarse sand) and jointed with gray cement slury mixed with
pigment to match the shade of slab including rubbing and polishing etc.
complete. (upto 10 ton) 105.43 Sq.mt 1172.51 11.73 1184.24
Anand SOR 2024-25-16 Item code - 14013A, Page No –
Providing and Laying black granite 18 mm thick & Kota stone 30 mm thick
sandwich type pentry platform base of cement mortar 1 : 6 ( 1 cement :
coarse sand ) for Pantry Counter Platform necessary edge molding as
directed by E.I.C. selection including all materials and labour etc. & also for
providing provision for fixing the kitchen sink. complete as per detail drawing
and instruction of Engineer-in-charge.
As per rate analysis
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying Black Granite 18 to 20 mm thick ,soffits of door &
window on 10mm thick cement mortar bed 1:3 (1-cement : 3-coarse sand)
and jointed with cement slurry including full round Moulding as directed
and granite approved by engineer in-charge.
Provoding and fixing flush door shutters , solid core construction with frame
of first class hardwood uniformly seasoned and treated
with cross board confirm to IS:2202 (Part 1) – 1999 and Hot-pressed with
cross-bands and face veneers and Decorative High Pressure Laminate (HPL)
of nominal thicknes of 1.0mm, All vertical edges and top/bottom edges to be
finished with: bisen patti made of Seasoned hardwood (teak/steam
142 beech/matching to frame) 25 mm wide, rebated and securely glued and
nailed/screwed with PU / Melamine Polish / Paint as specified
including anodised alluminium butt hinges, cylindrical knob with key with
necessary screws. (B)decorative type and block board core Handle for doors
of Brass 15cms Length butt hinges of brass make in flush door shutters
Hinges butt .I.S.I Mark Brass of
7.5cms .Length or equivalent (2) 30 to 35 mm thick. 102.56 Sq.mt 4700.00 47.00 4747.00
As Per Market rate
Polishing with french polish on new wood and wood based surface to give an
143 even surface including cleaning, the surface of all dirt, dust and sand
papering smooth and including a coat of wood filler. 102.56 Sq.mt 138.43 1.38 139.81
Anand SOR 2024-25 Item code - 19017, Page No –
Providing & fixing 3/4 aluminium section sliding window 2 shutter glass,
shutter mosquito net with colour anodizing or powder coating along with all
accessories complete fitting as per your requirement. Interlock section size :
144 40x18x1.5mm, Interlock section size : 40mmx18mmx1.5mm, Handle section
size : 40x18x1.5mm, Top & bottom section size : 40x18x1.5mm, Three track
top section size : 92x31.75x1.5mm, Three track bottom section size :
92x31.75x1.5mm, 5mm thk glass of saint gobain or modi gaurd
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and fixing standared extruded of alluminium section of size 63mm
x 38.10mm x 1.2mm (Jindal Section :2434, @ Wt. 0.643 Kg/mt) with colour
anodized alluminium frame for ventilation with 5 mm thick frosted glass as
details etc complete for Ventilation
Anand SOR 2024-25 Item code - 11030, Page No –
Providing & fixing aluminium section sliding door three track with colour
anodizing or powder coating along with all accessories complete fitting as
per your requirement. Door vertical section size : 47.62x44.45x2.9mm, door
top section size : 47.62x44.62x2.9mm, door bottom section size :
83.5x44.45x2.9mm, sliding G. channelsection size : 40x40x2.9mm, glazing
clip section size : 19x19x1mm, 5mm thk glass of saint gobain or modi guard
Providing & fixing 3/4 aluminium openable window with colour anodizing or
powder coating along with all accessories complete fitting as per your
requirement. Handle section size : 40x18x1.5mm, P.Pipe section size :
35x25x1.5mm, 5mm thk glass of saint gobain or modi gaurd
Providing and fixing FRP frame size 100x50 mm and 28mm thick FRP depress
panel shutter having extra reinforcement on sides & edges in Gel coat finish.
The core of the shutter & frame is to be filed up with injected fire retardant
grade polyurethene foam done in situ alongwith embedded wooden pieces
148 for stiffening & also taking hinges & fintures. The whole FRP frame & shutter
is to be water proof weather proof, termite proof & resistance to mild
acid/alkali.Rates are to be inclusive of S.S hinges, cylindrical knob without
key with necessary screws &alluminium fixtures & fastenings & fastener
Anand SOR 2024-25 Item code - 10037, Page No –
FABRICATION WORK
Providing and fixing M.S. grills of required pattern to wooden frames of
windows etc. with M.S. flats at required spacings and frame alround, square
or round bars with round headed bolts and nuts or by screws. (B)
ORNAMENTAL GRILL (upto 10 ton) 2145.72 Kg 146.53 1.47 148.00
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Anand SOR 2024-25 Item code - 10025BA, Page No –
Providing and fixing (kich, dline,Q rail) stainless steel ( grade 304 ) railing
made of hollow tubes, channels, plates, etc. including welding,grinding,
buffing, polishing, and making curvature ( wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete,i/c fixing the
railling with necessory accesories & stainless steel dash fasterners. stainless
steel bolts etc of required size,on the top of the floor on the side of waist
slab with suitable arrangement as per approval of engineer - incharge. (
railing as per detail drawing) STAIRCASE RAILLING (SS 304 - 16 SWG Railling)
Providing and fixing (kich, dline,Q rail) stainless steel ( grade 304) railing
made of hollow tubes, channels, plates, etc. including welding,grinding,
buffing, polishing, and making curvature ( wherever required) and fitting the
same with necessary stainless steel nuts and bolts complete,i/c fixing the
151 railling with necessory accesories & stainless steel dash fasterners. stainless
steel bolts etc of required size,on the top of the floor on the side of waist
slab with suitable arrangement as per approval of engineer - incharge. (
railing as per detail drawing) (SS 304 - 16 SWG Railling) Railling at balcony,
besides lift & at terrace.
Providing cement vata (10cm. x 10 cm. size) quarter round in cement mortar
1:1 including neat cement finishing, watering etc. complete.
Anand SOR 2024-25 Item code - 17015, Page No -145
Applying and fixing Granite stone cladding in line and level with necessary
153 filling material and chemial as per instruction by site engineer incharge with
material etc complete fitting 12.30 Sq.mt 3965.00 39.65 4004.65
Providing and laying Black Granite 18 to 20 mm thick on 10mm thick cement
mortar bed 1:3 (1-cement : 3-coarse sand) and jointed with cement slurry
including full round Moulding as directed and granite approved by engineer
in-charge. Above planter wall 8.38 Sq.mt 3965.00 39.65 4004.65
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and laying cement based Indian type waterproofing treatmemrnt
inclusive of cleaning the slab/floor by wire brush and drench the slab with
water and applying cement slurry with Sika Latex in required proportion
including cleaning , roughning and opening the cracks in 'V' groove pattern
and filling the same with C.M (1:1) on slab/floor and providing and laying
mm thick layer of C.M (1:2) mixed with waterproofing compound of 'Sika"
make in given proportion, providing and laying best quality , well burnt brick
bats(minimum size of brick bats 40mm) tightly and neatlyin C.M. in required
thickness to get proper slope and gradient at the starting point i.e. centre of
terrace or at starting of gradient (minimum thickness of water spout should
be 65mm) and filling the joints with C.M (1:1) mixed with above water
proofing compound.
water proofing of water tank raft as above ( as per market rate ) 175.00 Sq.mt 998 9.98 1007.98
As per rate analysis
Finishing the surface with 20mm thick CM 1:2 and china mosaic tilling and
finally finished the surface with trowel white cement slurry. After finishing
the whole terrace shall be flooded with water for a period of two weeks etc.
to work at all height complete as per instructions.
As Per Market rate
FABRICATION WORK
157 M S ladder with material complete fitting. 726.66 Kg 180 1.80 181.80
Steel work, welded in built up sections framed work including cutting,
hoisting, fixing in position and applying a priming coat of read lead paint.
158 (A)In beams and joists, channels angles Tees, flats, with connecting plates or
angle cleats as in main and cross beams. Hip and jack rafters, purlins
conneted to common rafters and the like (upto 10 ton)
Anand SOR 2024-25 Item code - 11002AA, Page No –
Providing and Fixing in first class teak wood batten patti (size - 50mm X
160 Providing throating or plaster drip and moulding to R.C.C Chhajja 65.80 Rmt 42.62 0.43 43.05
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Anand SOR 2024-25 Item code - 5018, Page No –
161 Entrance gate (Fixed fabrication + sliding gate) 176.01 Sq.mt 4550 45.50 4595.50
Applying priming coat over new steel and other metel surface after and
including preparing the surface by throughly cleaning, oil,grease, dirt and
other foreign matter and scoured with brushes fine steel wood, scrapers and
sand paper with ready mixed priming paint brushing red lead.
Anand SOR 2024-25 Item code - 19001, Page No –
Anand SOR 2024-25 Item code - 19002, Page No –
Painting two coats (excluding priming coat) on new steel and other metal
surface with enamel paint, brushing, interior to give an even shade including
cleaning the surface an even shade including cleanicn the surface of all dirt,
dust and other foreign matter. 440.02 Sq.mt 86.94 0.87 87.81
Anand SOR 2024-25 Item code - 19002, Page No –
164 Letter box with powder coated as per design of Engineer-in-charge 12.00 Nos 580 5.80 585.80
165 S.S House number plate of 8"x3"as per design of Engineer-in-charge
166 Parking sign made by ACP Sheet 300 x 300mm with writing. 8.00 Nos 425 4.25 429.25
Fiber roofing for covering OTS - 35 X 35mm M.S.Tube fabricated with
mmthick fiber sheet with complete fitting. 20.00 Sq.mt 2238 22.38 2260.38
Providing and fixing pre-cast Rubber Dye / steel Dye
inter locking concrete block 60mm thick with grade of
concrete M300 pnumatic compressed / vibrated
168 mechanically and as per approved design Confirming to
IS 15658 : 2006 including 35 mm Sand layer for levelling
and filling the joint with sand in proper line and level as
per guidlines of IRC : SP 63-2018 etc. Complete. 309.99 Sq.mt 699.93 7.00 706.93
Anand SOR 2024-25 Item code -14033, Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Excavation in any soil upto 30cm depth, breaking clods, removing unwanted
stuff such as brickbats, stones, grass roots etc. refilling the same, preplanting
watering, weeding, top-digging, relevelling and bringing the earth to fine
tilth, ready for sowing or planting.
Parks & garden SOR 2012-13 Item no-1, page no-4
Laying out Lawn : After excavating soil upto 30cm, preparing soil for planting
by supplying & mixing farm yard manuare at the rate of 5 cu.m per 100 sq.mt
170 area, providing & planting suckers of pure dharo (doob) grass roughly at
cm x 10 cm distance and maintaining till well established etc. complete
Parks & garden SOR 2012-13 Item no-19, page no-8
Architecture Tower name board with led light (Acrylic glow sign board -
Rs.1600/sqft) Design as per detail drawing. 1.00 No 39400 394.00 39794.00
Providing and fixing 19 mm thick water proof plywood shutters with both
side laminate at loft level and shelves for cupboards etc. including anodised
alluminium butt hinges & handle with necessary screws. (A) 19 mm water
proof plywood . (i) Fully Panelled. (upto 10 ton)
Anand SOR 2024-25 Item code – 10006AA, Page No -97
Providing wood work in frames of Doors, windows cleare
173 story windows and othersimilar works wrought, framede
and fixed in position. (A) Indian Teak Wood 2000.00 Cu.mt 604.19 6.04 610.23
Anand SOR 2024-25 Item code - 10001A, Page No –
Appliying priming coat over new wood and wood based surface after and
including preparing the surface by throughly cleaning oil, grease, dirt and
other foreign matter, sand papering and knotting. (C) Ready mixed paint
brushing priming for enamel. Frame & shutters of cupboards
Anand SOR 2024-25 Item code - 19009C, Page No –151
Painting two coats (excluding priming coat) on new wood and wood based
surface with enamel paint, interior to give an even shade including cleaning
the surface of all dirt, dust and other foreign matter sand papering and
stopping. 689.87 Sq.mt 91.29 0.91 92.20
Anand SOR 2024-25 Item code – 19011, Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and fixing single layer waterproof gypusm board 12.5 mm thick of
the make Newgood Group Co. Ltd. or equivalent & Newgood Group Co. Ltd.
company sections using waterproof board of size 1220 mm x 1830 mm x
mm suspended by G.I suapender of size 25 mm x 3 mm with intermediate
channel of size 18 mm x 40 mm x 0.80 mm at 1220 mm center to center
ceiling section of size 40 mm x 35 mm x 0.55 mm at 457 mm center to center
and perimetre chanel A of size 20 mm x 27 mm x 30 mm x 0.50 mm at edges
& drops including paper tap sand sofit cleat, anchor fastener, scoch bolt
connecting cleat joining compound top coat on ceiling including making
necessary opening for light fitting, diffuser etc. complete as per detail 63.29 Sqmt 600.94 6.01 606.95
Anand SOR 2024-25 Item code - 16007, Page No –
Preparing structural design of RCC Under Ground / Partially under ground /
above high ground level Reservoir of 100000 liter capacity as per relevant
I.S.s and constructing the same, including excavation in all types of soil strata
(including rock) including shoring strutting if required, for loose soil / to
protect from collapse due to near by traffic load, casting 100 mm thick P.C.C.
177 leveling course in M-10, Refilling the pit with proper soil and disposing of the
surplus stuff within a lead of 50 meters. Including cement plaster in CM 1:2
with approved water proofing compound to inside water touching surface to
container. Including all types of labour and material charges of lowering,
laying, erecting / hosting and jointing of pipe assembly to inlet, outlet
overflow, washout and bye pass arrangement as per hydraulic design.
Providing and fixing accessories like MS / GI Ladder, CI Manhole frame and
cover, water level indicator, adequate cowl type ventilators or lantern type
ventilator with stainless steel jail.
B.B. Masonry chambers for valves. Providing and applying three coats of
cement paint / snowcem to the out side face of structure. It also includes
satisfactory water tightness test as per relevant I.S. code and painting name
of scheme and capacity on the tank as per direction of engineer in charge.
List of Indian Standards for Design of GSR / SUMP:-
The structural design of GSR shall be in accordance with provisions relevant
(1) I.S. 3370 part I & II 2009 or latest revised
(1.1) I.S. 3370 part III & IV 1965 or latest revised
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
(2) I.S. 456 – 2000 or latest revised.
(3) I.S. 1893 – 2000 – 1984 or latest revised.
(4) I.S. 875, Part – 1 to 3, 1987 or latest revised.
General Specifications:-
(1) Water depth in container shall be adopted as per data of tender. If
water depth is not specified the suitable water depth / acceptable to field
engineer in accordance with hydraulic requirement shall be adopted for
(2) Shape of container (in plan) specified by in data shall be adopted in
absence circular shape shall be adopted.
(3) Size shall be fixed as per availability of space (land area) at site /
acceptable engineer in charge.
(4) Effect of overlapping of pressure bulbs on soil due near by structure
and proposed sump should be considered.
(5) Care shall be taken that no damage should occur to nearby existing
structure. Compensation shall be paid for the same by agency.
(6) The minimum concrete grade for RCC shall be M-25.
(7) HYSD Fe 500 grade reinforcing bars confirming to I.S. 1786 / 1139 shall
be considered in design. CRS / TMT bars shall be provided. In saline
atmosphere corrosion resistance stainless steel / HCR rebar shall be
provided. Any other steel can be used with approval of C.E./ in situation of
non availability in market without extra cost.
(8) Minimum size (or thickness) of various components shall be provided
as per tender criteria / specifications in absence as per I.S./ Std. practice of
G.W.S.S.B. Minimum dimensions specified for various components in tender
data / specifications shall be provided without fail.
(9) The safe bearing capacity (SBC) shall be referred from SBC test report.
In absence of report it shall be referred from data sheet. If poor soil is found
/ water table is met with during excavation SBC shall be scientifically
ascertained and design shall be revise. No extra shall be paid for increase in
(10) CI pipes and special shall only be used if type is not specified in tender.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
(11) The rate shall include cost of dewatering during excavation making all
arrangement when water table meets within depth.
(12) The structure shall be designed properly to resist uplift due to ground
water table specified in data or actual ground water table meets with during
excavation. If GWT / Uplift is mentioned in tender and during excavation it
dose not meet 7.5% rate shall be reduced.
(13) GI pipes railing shall be provided when sump is more than 2 meter
above ground level.
(14) Appearance of structure should be aesthetically good looking
acceptable to authority.
(15) Any charge in size, shape, depth below GL, height above GL, water
depth, F.B., size of member etc can be permitted in exceptional case due to
site condition or hydraulic design requirement by C.E. No extra shall be paid
(16) Any charge in data, dimensions, shape, water depth, reduction in size if
permitted by competent authority and if it reduces quantity then payment
shall be reduced prorate.
(17) When capacity of GSR / Sump is > 20 lakh liters two or suitable
compartments acceptable to executive engineer shall be designed and
(18) Agency shall engage qualified (at least graduate) consulting engineer
for designing the structure and he / she shall visit the site for guidance of
(19) 75% part rate shall be payable for concrete, reinforcement and
plastering items of container until satisfactory hydraulic testing for water
tightness is performed as per tender condition. Till the work shall be treated
Above conditions / general specifications Item Code 1 to 19 are part and
parcel of tender (contact) and prevail over other provisions in tender.
1 lakh liter capacity 1.00 No. 711500 7115.00 718615.00
GWSSB SOR 2021-22Section -C, Sr no-2, Page no
178 Rain water harvesting 1.00 No. 150000 1500.00 151500.00
Material Description
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and installing of 140 mm PVC –U, supreme make, 6 kg pressure,
slotted casing pipe with 8 mm spirally perforated holes at 30mm intervals.
Rainy FL 500 1.00 No
Rainy FL 200 1.00 No
Labour Description
Drilling of Bore well of 300 mm dia clear, fixing of casing pipes collars and
cap with necessary
cutting, threading and welding including transportation of rig and
supporting vehicles crew charges and cost of consumables etc.
Development of BORING (COMPRESSOR) 5.00 Hr
Plumbing charges with material for diverting the Rain water from filter to
Bore well (Approx.
100 mtr) 1.00 Job
Providing and installing water recharge System including its filter tank as per
drawing issued by consultant and its down take pipe from roof of the
178 A building up to filter tank of size 1.2x1.2 x 1.0 meter of 9 inch brick wall all 1.00 Job 25285.00 252.85 25537.85
around with 6 inch thk pcc as base. and from filter tank up to boring well etc
complete as per instruction from site incharge
Providing and fixing KRANTI make Water meter including rubber pakking nut
bolt washer of approved qualtiy for vertical / underground pipe line etc.
complete and making and repairing hole/groove in wall trench/floor sump
testing etc. complete for all heights as per instructions. For 15mm dia valve.
Removal of rust by chemical application and Aply protective coat of Anti
Rust chemical to Existing steel bar of Column for All Diameter Bar Etc comp.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and Fixing all mentioned material with all material, labour charges
Handle for Cupboards etc. Brass 15 cms. Length 96.00 nos 75.42 0.75 76.17
S.S. Stopper 20 Cm long of ASIS 304 72.00 nos 126.27 1.26 127.53
S.S. Aldrop 30 Cm long of ASIS 304 Grade 72.00 nos 396.61 3.97 400.58
S.S. Handle for Door 15 Cm size of ASIS 304 Grade 72.00 nos 75.42 0.75 76.17
Anand SOR 2024-25 Item code – M706 M 710, M712 Page No –
Painting two coats (excluding priming coat) on new wood and wood based
surface with ready mixed paint, brushing, oil, gloss, semi gloss to give and
even shade including cleaning of all dust, dirt and other foreign matter sand
papering and stopping
Anand SOR 2024-25 Item code –Item code -19014 Page No –
providing and fixing necessory rebaring in RCC Member up to depth 125mm
183 to 175mm for following dia WITH HILTY Chemical or suggested by engg i/c
184 providing and fixing necessory core cutter in RCC Member for following Dia
supplying providing and fixing of kitchen basket of SS 202 make as per
185 approved quality /Brand and design by client / site in charge including its 12.00 nos 16000.00 160.00 16160.00
accessories and fitting etc complete.
Providing and fixing M.S. grills of required pattern of windows aND OPENING
OF BALCONEY etc. with M.S. Bright bar Rod of 12mm thickness at required
186 spacings and frame alround, square or round bars with round headed bolts 2000.00 kg 105.18 1.05 106.23
and nuts or by screws (A) required spacings and frame alround, square or
round bars with round headed bolts and nuts or by screws (A) Plain Grill.
Anand SOR 2024-25 - 10025AA - pg no .
PART : A Total cost of Civil work Rs/-
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing laying and jointing in true line and level
15mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water concele/open as directed
by engineer incharge-archeitect
including fittings make PRINCE / SUPREME / ASTRAL /
FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Anand SOR 2024-25 Item code –23061 Page No –
Providing laying and jointing in true line and level
25 mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water concele/open as directed
by engineer incharge-archeitect
including fittings make PRINCE / SUPREME / ASTRAL /
FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Anand SOR 2024-25 Item code –23062 Page No –
Providing laying and jointing in true line and level
32mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water concele/open as directed
by engineer incharge-archeitect
including fittings make PRINCE / SUPREME / ASTRAL /
FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Anand SOR 2024-25 Item code –23063 Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing laying and jointing in true line and level
40mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water concele/open as directed
by engineer incharge-archeitect
including fittings make PRINCE / SUPREME / ASTRAL /
FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Anand SOR 2024-25 Item code –23064 Page No –
Providing laying and jointing in true line and level
50mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water concele/open as directed
by engineer incharge-archeitect
including fittings make PRINCE / SUPREME / ASTRAL /
FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Anand SOR 2024-25 Item code –23065 Page No –
Providing laying and jointing in true line and level
65mm dia. U.P.V.C. Pipe ( SCH- 40) for cold water concele/open as directed
by engineer incharge-archeitect
including fittings make PRINCE / SUPREME / ASTRAL /
FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing laying and jointing in true line and level
20mm dia. C.P.V.C. Pipe ( S.D.R. 13.5 ) confirming ASTM D-2846 for hot
water concele/open as directed by engineer incharge-archeitect
including fittings make PRINCE / SUPREME / ASTRAL /
FINOLEX or equivalent as approved by Engineer In
Charge. Pipe shall be fixed on the wall with the help of
clamp at every two metre C/C or shall be concelled as
directed including necessary fittings etc. including
testing of pipe and joints and fixing the same with
adhesive solvent, including cost of all materials.
Anand SOR 2024-25 Item code –23056 Page No –
Providing and fixing U.P.V.C. ball valve comprising of
PRINCE/SUPREME/ASTRAL/FINOLEX with union required at one or both side
of valves as per site condition jointing materials like Sovelent cement &
Teflon tape etc comp. For 40 mm dia
Providing and fixing U.P.V.C. ball valve comprising of
PRINCE/SUPREME/ASTRAL/FINOLEX with union required at one or both side
of valves as per site condition jointing materials like Sovelent cement &
Teflon tape etc comp. For 50 mm dia
Providing and fixing U.P.V.C. ball valve comprising of
PRINCE/SUPREME/ASTRAL/FINOLEX with union required at one or both side
of valves as per site condition jointing materials like Sovelent cement &
Teflon tape etc comp. For 65 mm dia
Providing and fixing Brass valve comprising of zoloto/Kartar or equivalent
with union required at one or both side of valves as per site condition
jointing materials like Sovelent cement & Teflon tape etc comp. for 32 mm
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and fixing PRINCE/SUPREME/ASTRAL/FINOLEX make P.V.C. ( B -
Type ) pipe line concealed or open directed by architect or engineer
incharge for drainage soil / waste disposal comprising IS 13592:92 necessary
fittings like plain or door Tee,yee,bend & reducer etc comp.conf.IS 14735:99
12 necessary clamps of heavy galvanized iron with nut, bolts & washers or 400.00 Rmt 529.7652 5.30 535.07
anchor fasteners to vertically open pipe line jointing materials like Sovelent
cement & rubber ring etc comp. making brick masonry or concrete support
to horizontal pipe line & providing full concrete below pipe line as bedding to
horizontal pipe line for 110 mm dia pipe
Providing and fixing 125 x 110mm size P trap of Finolex/Supreme make
including brick masonary in C.M. (1:4) and fixing trap in position including
15mm thick smooth cement plaster alround and fixing 30 X30cms pre-cast
cement concrete cover of approved quality on top including
making/repairing hole/groove/pipe connection where required,
watering,cleaning the site etc. complete as per instructions.
Providing and fixing SUPRIM / FINOLEX make Rigid P.V.C pipe 6 Kg. / Cm2 line
open for rain water disposal comprising IS 4985 necessary fittings like plain
or door Tee,yee,bend & reducer etc comp.conf.IS 4985 necessary clamps of
heavy galvanized iron with nut, bolts & washers or anchor fasteners to
vertically open pipe line jointing materials like Solvent cement etc comp. for
Providing and fixing SUPRIM / FINOLEX make Rigid P.V.C pipe 6 Kg. / Cm2 line
open for rain water disposal comprising IS 4985 necessary fittings like plain
or door Tee,yee,bend & reducer etc comp.conf.IS 4985 necessary clamps of
heavy galvanized iron with nut, bolts & washers or anchor fasteners to
vertically open pipe line jointing materials like Solvent cement etc comp. for
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing laying (to level or slopes) and jointing
reinforced concrete Light duty non-pressure pipes I.S.
16 class NP2 of the following internal diameter with collars 105.00 Rmt 249.72 2.50 252.22
and butt ends prepared for collar joints including
testing of joints complete.(B) 250mm (upto 10 ton)
Anand SOR 2024-25 Item code –24007BA Page No –
Providing and laying Cement concrete 1:5:10 (1-Cement
: 5-Fine sand :10-Graded stone aggregate 40mm
17 nominal size) bedding for stoneware pipes of following 5.00 Rmt 125.9 1.26 127.16
internal diameters with necessary formwork and curing
complete.(A) 100 mm dia. (112 mm Ave.bed thickness)
Anand SOR 2024-25 Item code –24002A Page No –
Providing and laying Cement concrete 1:5:10 (1-Cement : 5-Fine sand :10-
Graded stone aggregate 40mm nominal size) bedding for stoneware pipes of
following internal diameters with necessary formwork and curing
complete.(B) 150mm dia. (166mm Ave. bed thickness)
Anand SOR 2024-25 Item code –24002B Page No –
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-cement :2-coarse
sand : 4-graded stone aggregate 20mm nominal size) foundation concrete
1:3:6 mix (1cement : 3- coarse sand :6-Brick bats 40 + 50mm size) inside
plastering 15mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse sand)
finished with a floating coat of neat cement and making channels in cement
concrete 1:2:4 mix (1-Cement :2-Coarse sand :4-stone aggregate 20mm
19 nominal size) finished smooth complete including curing and festing (i) Inside 11.00 Nos 10933.41 109.33 11042.74
size 900mm x 1200mm and 1.5M. deep including C.I. cover with frame size
560mm diameter total weight of cover and frame to be not less than 128 kgs.
(Wt. of cover 64 Kg. and Wt. of frame 64 Kg.)(A) With 230mm thick walls of
brick msonry using brick having crushing strength not less than 35Kg. /
Sq.cm. in Cement Mortar 1:5 (1- Cement: 5-Coarse sand) (1) A type depth
0.90 Metre for 150mm diameter sewer.
Anand SOR 2024-25 Item code –24008A Page No –
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and fixing S.W. gully trap with C.I. grating
brick masonry chamber and water tight C.I. cover with
20 frame of 300mm x 300mm size (inside) with standard 4.00 Nos 1279.4 12.79 1292.19
weight.(i) Square mouth traps. (A) 100mm x 100mm
size P type. (upto 10 ton)
Anand SOR 2024-25 Item code –24006AA Page No –
Providing & Fixing first quality Ceramic EWC Wall Hung with 40mm Metro
Pole , P & F solid type seat & cover with installation of EWC with other
21 accessories in proper line & levels etc comp. white coloured EWC . 14.00 Nos 8000 80.00 8080.00
Jaquar/Cera/Hindware, make with flow rates as given under special
conditions of contract.
Providing and fixing washbasin with single hole with pillar
tap with C.I. or M.S. brackets painted white including Angle cocks,
connection pipe, bottle trape, waste coupling etc.
(A) Vitreous China:(ii) Flat Back washbasin
mm x v 400mm size. (i) In white colour. jaquar/ cera/hindware make with
flow rates as given under special conditions of contract
Providing & Fixing BIB COCK for kitchen and bathroom with wall falnge and
23 aerator with all labour and fittings charges.CERA Brand : GARNET / BRAVIO / 24.00 Nos 828 8.28 836.28
VICTOR any one series as per instructed by EIC.
Providing & Fixing ANGLE COCK for kitchen, wash and bathroom area with
25 wall flange with all labour and fittings charges.CERA Brand : GARNET / 60.00 Nos 742 7.42 749.42
BRAVIO / VICTOR any one series as per instructed by EIC.
Providing & Fixing KITCHEN SINK COCK wall mounted with 150mm (6'') long
swivel spout and wall flange for Kitchen sink with all labour and fittings
charges.CERA Brand : GARNET / BRAVIO / VICTOR any one series as per
instructed by EIC.
Providing & Fixing WALL MIXER with bend pipe for overhead shower with all
27 labour and fittings charges.CERA Brand : GARNET / BRAVIO / VICTOR any one 12.00 Nos 3700 37.00 3737.00
series as per instructed by EIC.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & Fixing Overhead Rain SHOWER Cera Brand, Square - ABS 100 x
28 100mm (4''x4'') with 200mm (8'') long shower arm with all labour and fittings 12.00 Nos 1050 10.50 1060.50
Providing & Fixing TWO WAY BIB COCK with side handle, wall flange and
29 aerator with all labour and fitting charges for Toilet.CERA Brand : GARNET / 12.00 Nos 1500 15.00 1515.00
BRAVIO / VICTOR any one series as per instructed by EIC.
Providing & Fixing CERA brand HEALTH FAUSET ABS Body with 1 meter SS
braided connection pipe for Toilet with all labour and fitting charges.
Providing and fixing Brass valve comprising of zoloto/Kartar with union
31 required at one or both side of valves as per site condition jointing materials 13.00 nos 6687 66.87 6753.87
like Sovelent cement & Teflon tape etc comp. for 63mm dia
Providing and fixing Brass valve comprising of zoloto/Kartar with union
32 required at one or both side of valves as per site condition jointing materials 8.00 nos 3910 39.10 3949.10
like Sovelent cement & Teflon tape etc comp. for 50mm dia
Providing and fixing Brass valve comprising of zoloto/Kartar with union
33 required at one or both side of valves as per site condition jointing materials 8.00 nos 2668 26.68 2694.68
like Sovelent cement & Teflon tape etc comp. for 40mm dia
Providing and fixing Brass valve comprising of zoloto/Kartar with union
34 required at one or both side of valves as per site condition jointing materials 24.00 nos 1532 15.32 1547.32
like Sovelent cement & Teflon tape etc comp. for 25mm dia
Providing and Fixing UPVC Brass MT 63mm of approved brand and
specifications with all labour and fitting charges.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and Fixing UPVC Brass MT 50mm of approved brand and
specifications with all labour and fitting charges.
Providing and fixing 152mm X 152mm size S.S. dome type gratings/jalee of
approved quality and of required design for waste pipe making and repairing
37 sides using one's own neat cement/ white cement, cleaning the etc. 60.00 Nos 67.67 0.68 68.35
complete for all heights as per instructions. Jaquar, Kohler, Cera,
Hindware,Parryware or equivalent make.
Providing and fixing Kitchen sink with s.s. sink
brackets, painted white including cutting holes in walls
and making good the same but excluding fittings. (C)
Vitreous China Sink.(i) 600mm x 450mm x 150mm size. Jaquar, Kohler, Cera,
Hindware,Parryware or equivalent make with flow rates as given under
special conditions of contract
Anand SOR 2024-25 Item code –23019 Page No –
Providing and fixing C.P. brass towel rail comlete with
C.P. brass brackets fixed to wooden plugs with C.P.
brass scews.(B) 600mm x 20mm size. Jaquar, Kohler, Cera,
Hindware,Parryware or equivalent make
Anand SOR 2024-25 Item code –23025 Page No –
Providing & Fixing c.p. Heavy SOAP DISH comprising of make Jaquar,
Kohler, Cera, Hindware,Parryware or equivalent make
Providing & Fixing c.p. Heavy PAPER HOLDER comprising of make Jaquar,
Kohler, Cera, Hindware,Parryware or equivalent make
Anand SOR 2024-25 Item code –23027 Page No –
Providing & Fixing c.p. Heavy OPEN MIXTURE comprising of make Jaquar,
42 Kohler, Cera, Hindware,Parryware or equivalent make with flow rates as 14.00 Nos 3500 35.00 3535.00
given under special conditions of contract complete for 15 mm dia
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & Fixing Submersible Pump for under ground tank to over head
tank P & F submersibal pump 2.5 H.P. 20,000 L/H @ 30mt. head with solid
base including tee, elbow & union etc. comp. one working one standby with
casced system including level sensor & pennel etc. Comp,
PART : B Total cost for Plumbing work Rs/-
Note : All SOR Items (no.01 to 41) are as per Electrical SOR 2025-26
CHAPTER - I WIRING
SECTION - 1-2 Point wiring in Copper (MODULAR)
Point wiring for secondary light point with 2 wires of 1.0 sq.mm & earthwire
of 1.0 sq.mm (green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multistrand copper wires (Make- Havelles -FRLSH / LAAP- FRLSH / APAR-
ANUSHKATI ) , in Rigid PVC pipe having size of 25 mm (Make - Pricision -
MMS category / Nihir - MMS category) to be erected concealed in / flushed
on wall/ceiling, complete with earth continuity and necessary connection
with primary light with accessories erected on Metal / PVC box covered
with 3 mm thick PC(Polycarbonet) / Acrylic sheet for concealed wiring. with
1 necessary Lamp holder / ceiling rose / H.D.Connector as directed. Note:- # 30 Pt. 131 1.31 133
Maximum up to 6 mtrs length, excess will be considered as Mains for
Secondary Point. # Quoted Rates are inclusive with medium class Rigid PVC
pipe and accessories. # Make for Switches /MS Concealed Box and related
accessories - Anchor ROMA PLUS ONLY. # All wires used in the project with
90 mtrs coil only # GI Point Box should be made from 1.5mm thick GI sheets.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Point wiring for Two Way Controlled Light Point with 2 wires of 1.0 sq.mm &
earthwire of 1.0 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires (Make- Havelles -FRLSH / LAAP- FRLSH /
APAR- ANUSHKATI ) , in Rigid PVC pipe having size of 25 mm (Make -
Pricision - MMS category / Nihir - MMS category) to be erected concealed in
/ flushed on wall / ceiling complete with 6A Tissino Type ISI marked
accessories with earth continuity erected on Metal/PVC//Wooden box
covered with 3 mm thick PC(Polycarbonate) / Acrylic sheet. with necessary
Lamp holder/ceiling rose / H.D.Connector as directed. Note:- # Maximum up
to 10 mtrs length, excess will be considered as Mains for Secondary Point. #
Quoted Rates are inclusive with medium class Rigid PVC pipe and
accessories. # Make for Switches /MS Concealed Box and related accessories
- Anchor ROMA PLUS ONLY. # All wires used in the project with 90 mtrs coil
only # GI Point Box should be made from 1.5mm thick GI sheets.
Point wiring for Light / Bell with 2 wires of 1.0 sq.mm & earthwire of
sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated
multistrand copper wires (Make- Havelles -FRLSH / LAAP- FRLSH / APAR-
ANUSHKATI ) , in Rigid PVC pipe having size of 25 mm (Make - Pricision -
MMS category / Nihir - MMS category) to be erected concealed in/ on
surface on wall/ceiling complete with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on PVC / Metallic
box, single mounting base frame covered with textured/metallic front plate
modules erected on / in wall / ceiling as per pipe erected, with necessary
Lamp holder/ceiling rose / H.D.Connector as directed.CAT -III Note:- #
Maximum up to 10 mtrs length, excess will be considered as Mains for
Secondary Point. # Quoted Rates are inclusive with medium class Rigid PVC
pipe and accessories. # Make for Switches /MS Concealed Box and related
accessories - Anchor ROMA PLUS ONLY. # All wires used in the project with
90 mtrs coil only # GI Point Box should be made from 1.5mm thick GI sheets.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Point wiring for FAN with 2 wires of 1.0 sq.mm & earthwire of 1.0 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand
copper wires (Make- Havelles -FRLSH / LAAP- FRLSH / APAR- ANUSHKATI )
in Rigid PVC pipe having size of 25 mm (Make - Pricision - MMS category /
Nihir - MMS category) to be erected concealed in/ on surface on
wall/ceiling complete with 6A Modular type switch and 2 Modular Type hum
free EME four or more step type electronic fan regulator with separately
mounted and accessories with earth continuity of following type erected on
PVC / Metallic box, single mounting base frame covered with
4 textured/metallic front plate modules erected on / in wall / ceiling as per 92 Pt. 632 6.32 638.32
pipe erected. with necessary ceiling rose / H.D.Connector as directed.Cat. III
Note:- # Maximum up to 10 mtrs length, excess will be considered as Mains
for Secondary Point. # Quoted Rates are inclusive with medium class Rigid
PVC pipe and accessories. # Make for Switches /MS Concealed Box and
related accessories - Anchor ROMA PLUS ONLY. # All wires used in the
project with 90 mtrs coil only # Rates inclusive of cost for GI FAN BOX with
FAN HOOK # GI Point Box should be made from 1.5mm thick GI sheets.
Point wiring for Individual Plug with & earthwire of 1.5 sq.mm (Green) both
are of ISI marked 1.1 KV grade FRLS PVC insulated multistrand copper wires
(Make- Havelles -FRLSH / LAAP- FRLSH / APAR- ANUSHKATI ) , in Rigid PVC
pipe having size of 25 mm (Make - Pricision - MMS category / Nihir - MMS
category) , to be erected concealed in / on surface of wall / ceiling complete
with Modular type switch & 5 pin Plug erected on PVC / Metallic box
covered with appropriate front plate modules erected on / in wall / ceiling as
per pipe erected with following type of accessories. [I] For 6A Plug and 6 a
5 switch with 2-1.5 sq.mm Cu. Wire from nearby switchboard/mcb db board 157 Pt. 471 4.71 475.71
Cat.III Note:- # Maximum up to 10 mtrs length, excess will be considered as
Mains for Secondary Point. # Quoted Rates are inclusive with medium class
Rigid PVC pipe and accessories. # Make for Switches /MS Concealed Box and
related accessories - Anchor ROMA PLUS ONLY. # All wires used in the
project with 90 mtrs coil only 1-2-3 # GI Point Box should be made from
1.5mm thick GI sheets.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Point wiring for Looped Plug with 6A Modular type switch & 5 pin socket
erected on PVC / Metallic box, single mounting base frame covered with
textured / metallic front plate modules erected on / in wall / ceiling with
6 following type accessories. Cat. III Note: # Make for Switches /MS Concealed 49 Pt. 255 2.55 257.55
Box and related accessories - Anchor ROMA PLUS ONLY. # GI Point Box
should be made from 1.5mm thick GI sheets.
Providing following type of Modular Type Accessories mounted with pvc /
metallic box, single mounting base frame covered with textured / metallic
front plate , modules erected with necessary connection. As desired by
Engineer In charge Note: # Make for Switches /MS Concealed Box and
related accessories - Anchor ROMA PLUS ONLY. SOR 1-2-6
(4) TV Co-axial Socket outlet Cat.III 12 Ea. 159 1.59 160.59
(7) Blank Plate Single Cat.III 48 Ea. 25 0.25 25.25
(9) 16 Amp. SP one way switch Cat.III 84 Ea. 179 1.79 180.79
(10) 6/16Amp. Universal socket Cat.III 84 Ea. 198 1.98 199.98
(19) Modular Indicating Call Bell Cat.III 12 Ea. 326 3.26 329.26
(20) Modular Buzzer Cat.III 12 Ea. 148 1.48 149.48
Section :- 1- 3 / Conduits & Pipes
Providing and erecting ISI mark Medium class RIGID PVC PIPES of following
size complete to be erected on/in wall, ground or ceiling erected with
necessary PVC fittings & Junction boxes fixed with adhesive solution &
Clamps with following dia of pipes, in approved manner as directed BY EIC
(Make - Pricision - MMS category / Nihir - MMS category)
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & erecting PVC Corrugated Flexible Conduit with required nos. of
9 coupling, PVC bushes, Check-nuts etc. complete of following sizes. (Make -
Precision / Nihir)
Section 1-4 Mains & Wires
Mains with 2 Wire 2.5 Sq mm 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire (Make- Havelles -FRLSH / LAAP- FRLSH /
APAR- ANUSHKATI ) in Rigid PVC pipe having size of 25 mm (Make - Pricision -
MMS category / Nihir - MMS category) to be erected concealed in /flushed
10 on wall/ceiling, with 1.5 sq. mm copper conductor FRLS PVC insulated 2000 Mtr. 82 0.82 82.82
stranded wire of green colour for earth continuity. (From LDB to SB and SB)
Note:- # Quoted Rates are inclusive with medium class Rigid PVC pipe and
accessories. # All wires used in the project with 90 mtrs coil only
(a) with medium class Rigid PVC pipe and accessories
(a) 2 wire 1.0 sq. mm with 1.0 sq.mm Earth Wire 60 Mtr. 42 0.42 42.42
Mains with 2 Wire 4.0 Sq mm 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire (Make- Havelles -FRLSH / LAAP- FRLSH /
APAR- ANUSHKATI ) in Rigid PVC pipe having size of 25 mm (Make - Pricision -
MMS category / Nihir - MMS category) to be erected concealed in /flushed
11 on wall/ceiling, with 2.5 sq. mm copper conductor FRLS PVC insulated 1000 Mtr. 111 1.11 112.11
stranded wire of green colour for earth continuity. (From LDB to SB and SB)
Note:- # Quoted Rates are inclusive with medium class Rigid PVC pipe and
accessories. # All wires used in the project with 90 mtrs coil only
(a) with medium class Rigid PVC pipe and accessories
(b) 2 wire 6 sq. mm with 4.0 sq.mm Earth wire 500 Mtr. 146 1.46 147.46
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & Erecting approved make following size of TV Co-axial flexible
cable comprising inner conductor of solid bare copper insulated with Foam
12 PE & Secondary conductor made of poly - Aluminium film bonded Al. Braids
@ suitable coverage overall sheathed with black PVC insulation.
1-4-6 (b) RG-6 (Make:- LAPPS / Havells) 360 Mtr. 39 0.39 39.39
Indoor LED Fittings
Erecting (only Installation) LED indoor fittings with LEDs of wattage 0.2 Watt
to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/ aluminium
die cast powder coated and high U.V. & corrosion resistance with diffuser
with company mark/name 160V to 270V, Power Factor more than 0.9, THD <
13 15%, CCT 3000 K to 6500K, Luminaire efficacy> 85 lumens/watt ,LED LED
driver efficiency > 85 % ( fitting required LM-79 & LM-80 Certificates)(NOTE:
Below description have shown ranges of Wattage capacity of LED fittings.The
Engineer incharge may select any wattage capacity between the ranges
(A) Tube Light with integral driver
(i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Erecting (only Installation) LED indoor fittings with LEDs of wattage 0.2 Watt
to 0.5 Watt assembled on single MCPCB, with housing used as a heat sink
shall be made of thick sheet Steel conforming to IS: 513/CRCA/aluminium
pressure die cast powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company mark/name 160V
14 to 270V,Power Factor more than 0.9, THD < 15CCT 3000 K to 6500K, %, V
LED driver efficiency > 85 % ( fitting required LM-79 & LM-80
Certificates)(NOTE: Below description have shown ranges of Wattage
capacity of LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount Downlight with
provision for spring loaded mounting clips complete.IP20 (only Installation)
(ii) 11-15 watts, Surge-2 KV (only Installation) Cat-lll 48 Ea. 34 0.34 34.34
SWITCHGEARS & DISTRIBUTION BOARDS
Section 3-4 MOULDED CASE CIRCUIT BREAKERS
Providing and erecting Approved make Four pole moulded case circuit
breaker having breaking capacity ICU of 35 KA. at 415 V. having Normal
current rating 200A.with variable Thermal & magnetic release suitable to
work on A.C.supply 50 c/s. with all internal connections, spreader tinned
copper & complete erected in existing 16 G.M.S.housing (Make - Schneider /
ICS=100% of ICU only Cat III 2 Ea. 16061 160.61 16221.61
Section 3-8 / PANEL MOUNTING BUSBARS
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Supplying and erecting triple pole & neutral 440V / 500V panel mounting
Copper Busbars with four equal Nos. of electrolyte bus having current
density not more than 1.6 Amp. / sq.mm (Rated current / cross section area)
duly wrapped with colour insulating tape for phase sequence of following
current carrying capacity, erected with necessary bus bar supports
/insulators, main cable socket to each bar, erected in existing cubical panel
with necessary connections.
(B) Suitable for 200 Amp. capacity 24 Rn.Mtr 3171 31.71 3202.71
SECTION 3-10 / MINIATURE CIRCUIT BREAKERS
providing and erecting Miniature circuit breaker single pole 6A to 25A
suitable to operate on 240 V A.C. system and having breaking capacity 10 KA
17 to be erected in existing box. confirming to IS 8828/1996 with ISI Mark Cat.III
(Make - Schneider Acti 09 Series / Legrand DX 3 Series)
Providing & erecting 240 V MCB double pole switch for motor & inductive
load (C Curve) having 10 KA breaking capacity & confirms to IS : 8828 in
existing box having 40 Amp Capacity . Cat.III (Make - Schneider Acti 09 Series
/ Legrand DX 3 Series)
Providing & erecting 415 V MCB Four Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
having40 Amp. capacity . Cat.III (Make - Schneider Acti 09 Series / Legrand
Providing & erecting 415 V MCB three Pole for Motor & Inductive Load (C
Curve) having 10KA breaking capacity & confirms to IS :8828 in existing box
having 6 to 32 Amp capacity as per SLD given by EIC Cat. III SOR 3-10-6
SECTION 3-11 MCB DISTRIBUTION BOARDS
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
21 Half / One Module Blanking Plate of Standard Size. 12 Ea. 9 0.09 9.09
Providing and erecting SPN double door (IP 43) Sheet Steel powder coated
MCB distribution board - flush / surface mounted fitted with busbar, neutral
link, earth bar and DIN rail, Conforms to IS 8623-1 & 3, IEC 61439-1 &
without MCB to house appropriate nos. of MCBs.(The DBs should be used of
same company of MCB to be used) suitable for single phase incoming and
horizontal single phase outgoing (Make - Schneider Acti 09 Series / Legrand
(A) single phase incoming and horizontal single phase outgoing
(b) sheet steel double door (IP-43)
SECTION 3-12 EARTH LEAKAGE CIRCUIT BREAKERS
providing and erecting Approved make 40 AMPS Double Pole RCCBs
conforming to IS: 12640 and having sensitivity of 30 mA and Short Circuit
withstand capacity of 10 KA and suitable for operation on single phase
V,50Hz. having characteristic of quick action & tripping with all advance
feature & do not incorporate any electronic component. for following Max.
rating erected as directed CAt. III (Make - Schneider Acti 09 Series / Legrand
SECTION 3-14 EARTHING
Providing and erecting required size HOT deep Galvanised iron strip for
24 earthing of H.T. , OCB/ ACB/ Transformer LT panel board, Motors etc. using 12 Kg. 77 0.77 77.77
proper clamp. (25x3MM)
25 Providing and erecting Annealed bare Copper wire 8 to 16 SWG. 6 Kg. 787 7.87 794.87
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Supplying & erecting in earthpit of minimum bore dia. 225mm size ASH or
approved make Safe Earthing Electrode consisting Pipe-in-Pipe Technology
as per IS 3043-1987 made of corrosion free G.I.Pipes having Outer pipe dia
of 80 mm having 80-200 Micron galvanising, Inner pipe dia of 40 mm having
200-250 Micron galvanising, connection terminal dia of 14 mm with
constant ohmic value surrounded by highly conductive compound with high
charge dissipation suitable for following type of applications.
[C] For Electrical Installation covering Transformer Neutrals, Lightning
arrester Earthing, A.C.Plant & Sensitive Computer System(like
Automation, SCADA)i.e. independent Earthing located in other than
normal soil i.e. Soft Rock, Marshy Soil etc. -Length of Pipe : 3 Mtrs. .-Back
filling Compound :2 nos Bags of 25 Kg. (MAKE:- Ashlok / ETP)
SECTION 3-16 / CUPBOARDS (PanelBoards)
Providing & erecting weather proof, dust & vermin proof, floor mounted
front operated indoor type cubical panel board having IP-64 protection
made from 14 SWG thick CRC M.S. sheet for outer body & doors, 16 SWG
thick CRC M.S.sheet for internal partitions with necessary supporting angles,
flats including cutting, bending, drilling, welding, riveting with internal
partitions & cable alley as per requirements & instruction of engineer-in-
charge with erection of
supplied switch gears, BUSBARS, with suitable size of inter connecting PVC
copper wire / copper-aluminium strips, rubber grommets, rib, bakelite
control fuses for measuring instruments, earth bus & earth bolts, foundation
flange - bolts-base Plates, sufficient nos. of hinged doors, handles with
locking arrangement and rubber gasket complete. The Panel shall be painted
with epoxy powder coating.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
(The rates excludes the cost of switchgears, bus bars, inter connecting mains
& Copper Aluminium strips, meters, Fuses etc. The dimension shall be
measured excluding base beams) The panel shall be supplied with only CPRA
approved manufacturers with following size. Panels to be provided with
Required Labels as per need, Panel provided should have provision for both
(Floor or Wall Mounting).
(i) with 350 mm depth
(1) METER BOARD - 1 FOR 11 Nos 3 Phase Meter 6 Sq.Mtr 14755 147.55 14902.55
(1) METER BOARD - 2 For 11 Nos 3 Phase Meter 6 Sq.Mtr 14755 147.55 14902.55
SECTION 4-4 / ARMOURED COPPER CABLES
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand
Copper conductor for 1.1 KV. to be laid on wall with necessary clamps or in
28 existing trench / pipe at road crossing or floor of following size of cable. (
Make- APAR - Anushakti / Havelles/ LAAP )
Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured cable multistrand /
Solid Copper conductor for 1.1 KV. to be laid on wall with necessary clamps
29 or in existing trench / pipe at road crossing or floor of following size of
cables. ( Make- APAR - Anushakti / Havelles/ LAAP )
SECTION 4-6 / CABLE GLANDS.
Providing and, fixing heavy duty flange type brass cable gland with rubber
ring for PVC insulated armoured cable complete with out going tails,
insulating tape etc for following size of cables. Make - HMI / Dowelles
SECTION 4-7 CABLE LUGS.
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Solder less crimping type Copper lugs conforming to IS suitable for cable of
following size evenly crimped with high pressure tool & connected to
switchgear terminals with brass/cadmium plated nut bolts in an approved
manner. Make - HMI / Dowelles
CHAPTER - V Fans and Accessories
SECTION 5-1 / CEILING FANS AND ACCESSORIES
Erecting (Only Installation) Approved make Ceiling Fan with double ball
bearing ISI mark with Condenser 230 volt A.C.50 Hz 1200 mm sweep
32 complete having 3 blades aluminium body and blade sets having ornamental 24 Ea. 51 0.51 51.51
design shanks , canopy erected with earthing.
Supplying & erecting single phase approved make industrial exhaust fan
suitable for medium duty ring mounted low noise operation suitable for
medium duty having following dia size and maximum speed in RPM Make :
[A] 305 mm dia 900 RPM
SECTION 5-2 FAN ACCESSORIES
Supplying and erecting 19 / 20 mm. nominal bore Medium Class M.S. Pipe
34 down rod erected duly painted for fan complete with proper insulation 12 Mtr 107 1.07 108.07
without leakage and earthing. (MAKE:- ZARAL)
OPEN WELL TYPE HORIZONTAL MONO BLOCK PUMPS
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing & erecting open well horizontal mono block pump set (Make :
Lubi) with cast iron body and copper rotor, complete for three phase
submersible motor having CAT II [C] For 3 HP 3 phase open well
horizontal mono block pump set suitable for 85 LPM to 270 LPM @ 11 mtr to
33 mtr head suitable for 50/65 mm dia delivery pipe. Note : Quoted rate
should be inclusive of the cost of: (i) DOL starter having short circuit
protection, Overload Protection, Single phase prevention , and under
voltage protection. (ii) GELCO or equivalent make Liquid Lever Controller
with necessary wiring
SECTION 9-6 SUBMERSIBLE PUMPS
S.I.T.C. submersible pump set suitable for bore of 150 mm. dia. or more
having three phase motor capacity not more than 5 H.P. with following
capacity . (A) (12 stage) 240 to 200 LPM discharge at 70 to 78 mtrs. head
respectively suitable for 50mm dia. delivery pipe Quoted rate should be
36 inclusive of the cost of (i) DOL starter having short circuit protection,
Overload Protection, Single phase prevention , and under voltage
protection. (ii) GELCO or equivalent make Liquid Lever Controller with
necessary wiring (Make:- Lubi) (Starter Make:- L&T
SECTION 9-7 PIPES AND PIPE FITTINGS
Providing and erecting ISI marked PVC insulated PVC Sheathed Flat flexible
37 Submersible copper cable approved make of following Size. Make :
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Supply, installing, testing and commissioning of metallic double door type
distribution board with following MCBs / ELMCBs / RCCBs / etc. with all
necessary connections etc. complete. DISTRIBUTION BOARDS 8-WAY
VTPN DB : (Common DB) 'Incoming : 100 A
MCCB (Make - Schneider Acti 09 Series / Legrand DX 3 Series)
'Outgoing : 6 to 32 A TP MCB (2 nos) (MCB TAKEN IN ABOVE SOR)
Outgoing : 6 to 32 A SP MCB (6 nos) (MCB TAKEN IN ABOVE SOR)
Excavation and backfilling of cable trench 900 mm deep complete with
39 compacting surplus soil and making a good finish level complete to the 30 Mtr 55 0.55 55.55
satisfaction of E.IC.
Supply and laying of Bricks on the cables in existing cable trench for cable
protection complete to the satisfaction of E.I.C.
Providing and erecting approved make 63 Amp Four Pole RCCBs confirming
IS12640 and having sesitivity 0-30 mAmp and shrt circuit withstand capacity
of 10 KA and suitable for operation on three phase and neutral 450 V 50 Hz
41 having charatristic of quick action and tripping with all advance features and 1 No 3010 30.1 3040.1
do not incorporate any electronic component as directed Make : Schinieder-
Acti 9 & Legrand DX-3
C TOTAL AMOUNT FOR SOR ITEMS (item Sr No 1 to 41)
C TOTAL AMOUNT FOR SOR ITEMS (item Sr No 1 to 41)
MARKET RATE ITEMS:-
LIGHTNING ARRESTOR AND CONDUCTORS :
Providing and fixing of lightning conductor finial made of 25 mm dia.
mm long, copper tube, having single prong at top, with 84 mm dia. 3 mm
thick copper base plate including holes etc. complete as required. (ISI
Rivetting, sweating and soldering of copper / GI tape (with another copper /
43 GI tape, base of the finial or any other metallic object) as per required. 10 nos 125 1.25 126.25
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Providing and fixing copper strip 19 mm x 3 mm thick on parapet or surface
of wall / on top of roof with insulated spacers / clamps at every 400 mm
interval for supporting lightning conductor as required.(for horizontal run). -
Providing and fixing copper strip 19 mm x 3 mm thick on surface of wall / on
RCC / steel column with insulated spacers / clamps at every 400 mm interval
for supporting lightning conductor as required.(for vertical run). -
PRECAST CHAMBER :
Supply and Install of PreCast Chamber 450 X 450 X 400 deep with cover with
frame complete.
MGVCL LIASIONING :
Liasioning Charges for getting approval from IMP Dept as well as Electrical
Inspector for High Rise Building and obtain 1 or 3 Phase 13 nos Permanent
Residential Connection from MGVCL (Rates inclusive of necessary
documentation with MGVCL - required documents / approved plans to be
furnished by University). This includes submission of applications to MGVCL
CABLE TRAY & STRUCTURAL STEEL :-
Supply, erection, fabrication and jointing of following size GI hot dip
galvanized cable tray with all accessories such as bends / cross / reducers /
Tee, with covers or without covers and clamps, GI hardwares, other
accessories etc. as per drawing and specification complete in line and level
etc. complete to the satisfaction of EIC (Galvanisation thickness shall not
been less than 75 micron)
150 x 25 x 2.0 mm Perforated cable tray with 160 x 10 x 2.0 mm plain GI
Estimate for Compound Wall For F.P. No : - 86 and
Sr No Description Qty Unit Rate 1% L.C. Total Rate Amount
Supply, erection, fabrication, cutting, welding and installation of structural
steel using m.s. angles, flats, channels etc. as per drawing and specification
with one coat of red-oxide paints and two coats of approved enamel paints
with all hardwares such as anchor fastners, GI nutbolts and washers etc.
complete to the satisfaction of EIC.
D TOTAL OF SR NO - 42 TO 49 (MARKET RATE ITEMS)
TOTAL COST FOR CIVIL, PLUMBING & ELECTRICAL WORK
(SOR & MARKET RATE ITEMS) (PART : A + B + C + D )
ADD FOR CGST AND SGST (18 %)
TOTAL COST FOR ADMINISTRARTIVE STAFF QUARTERS UNIT 2
Estimate for Compound Wall For F.P. No : - 86 and
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
SBD _ADM U2.pdf
SCHEDULE B_ADM U2 CIVIL_PLUMBING_ELECTRICAL.pdf
TENDER CONDITIONS_ADM U2.pdf
TENDER CONDITIONS_ELECTRICAL WORK_ADM U2.pdf
TENDER NOTICE_ADM U2.pdf
GR_1.pdf
GR_2.pdf
GR_3.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .