Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC KORAMANGALATH HOUSE TOMY LANE SOUTH PANAMBILLY NAGAR KADAVANTHRA P O KOCHI 682 020 | KOCHI | ERNAKULAM | KERALA | 682020 | L1 | Accepted-AOC Lowest tenderer | |
| 2 | L2₹41.9 L+₹2.9 L (7.55%)Rejected-Finance DOOR NO 42 2237 KRISHNA BEHIND ERNAKULAM MEDICAL CENTRE CENTURY CLUB ROAD VENNALA KOCHI 682028 | KOCHI | ERNAKULAM | KERALA | 682028 | L2 | Rejected-Finance Other than lowest tenderer | |
| 3 | Rejected-Technical | - | Rejected-Technical Due to not enlisted in reqd category |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
7 Jan 2020, 6:00 pmClosed
GE (NS) Kochi
Naval Base Kochi 682004
COMPREHENSIVE MAINT OF FIRE ALARM AND FIRE DETECTION SYSTEM AND OUTSOURCING OF SERVICES OF VARIOUS INSTALLATIONS AT NAVAL BASE KOCHI
2019_MES_303415_1
8681/E8 Comp Maint Fire Fighting
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
Nava Base Kochi
Class D
Category c vi and d v
7 documents required · 7 mandatory
₹500
Yes
GE (NS) Kochi
₹90,000
Yes
6 Mar 2020
3 Dec 2019
8 Jan 2020
3 Dec 2019
7 Jan 2020
17 Dec 2019
3 Dec 2019 - 16 Dec 2019
Amount
Providing services of ITI / ITC qualified tradesman (Electrician / Diesel Mechanic) from 0600 hours to 2200 hours in 2 shifts of 8 hours each shift (One Tradesman in each shift) for operation and maintanence of fire fighting pump house installation located at NIETT comprising of following equipments/ machines including testing and operation of valves and allied works including saturdays/ sundays/ holidays for operation of system as and when required and also to carry out minor repairs/ servicing/ rectification of faults as and when required to all machines/ Equipments and valves to ensure 100% serviceability of plants and removing grass/surface dressing from surrounding area, all as specified and as directed . (11 X 30 X 2 = 660 SHIFTS) (a) Electric driven pumpsets 60 HP - 1 No (b) Diesel engine driven set 75 HP - 1 No (c) Jockey pump set 20 HP - 1 No (d) Electric driven pump set 50 HP (Sprinkler) - 1 No
Providing services of One ITI / ITC qualified tradesmen (Electrician / Diesel Mechanic) from 0600 hours to 2200 hours in 2 shifts of 8 hours each shift (One Tradesman in each shift) for operation and maintanence of fire fighting pump house installation located at 550 Squadron Garuda comprising of following equipments/ machines including testing and operation of valves and allied works including saturdays/ sundays/ holidays for operation of system as and when required and also to carry out minor repairs/ servicing/ rectification of faults as and when required to all machines/ Equipments and valves to ensure 100% serviceability of plants and removing grass/surface dressing from surrounding area, all as specified and as directed . (11 X 30 X 2 = 660 SHIFTS) (a) Electric driven pump sets 75 HP - 1 No (b) Diesel engine driven set 85 HP - 1 No (c) Jockey pump set 12.5 HP - 1 No
Providing services of One ITI / ITC qualified tradesmen (Electrician / Diesel Mechanic) from 0800 hours to 1600 hours in one shift (One Tradesman in each shift) for operation and maintanence of Filteration Pump House installation located at Diving School comprising of following equipments/ machines including testing and operation of valves and allied works including saturdays/ sundays/ holidays for operation of system as and when required and also to carry out minor repairs/ servicing/ rectification of faults as and when required to all machines/ Equipments and valves to ensure 100% serviceability of plants and removing grass/surface dressing from surrounding area, all as specified and as directed (11 X 30 X 1 = 330 SHIFTS). (a) Pressure Filteration Plant 62 Cum/hour - 1 No (b) Pressure feed type vacuum chlorinator 01 to 1000 gram/hours - 1 No (c) Pump sets 7.5 HP - 2 Nos
Providing services of ITI / ITC qualified tradesman (Electrician / Plumber / Fitter/Diesel Mechanic ) from 0600 Hours to 2200 Hours in 2 shifts of 8 hours each shift (one tradesman in each shift) for operation and maintenance of Sewage treatment plant 30M Cum per Day capacity (30KLD ) located at NIAT (80 CPOs/50 POs Accn ) comprising of following Characteristic of Inlet raw sewage /out let treated sewage equipments/ machines and pump sets including testing and operation of valves and allied work including saturdays/ sundays/ holidays for operation of system as and when required and also to carry out minor repairs/ servicing/ rectification of faults as and when required to all machines/ Equipments and valves to ensure 100% serviceability and Maintain the E-COIL ppm level both inlet raw sewage and out let treated sewage of plants and removing Scaling Materials, mud Materials grass/surface dressing from surrounding area complete all as specified :- (11x30x2=660 shifts). (a) Monoblock pumpset (7 to 7.5 HP ) - 02 Nos (b ) Submersible pump set (5.5 HP to 8.5 HP ) - 02 Nos ( c) Bar Screen - 01 No (d) Tube Settler - 01 No (e) Air Blower - 02 Nos (f ) FAB Reactors - 02 Nos (g) Valve Different Sizes (h) Control Pannel -01 No
Providing services of ITI / ITC qualified tradesman (Electrician / Plumber / Fitter/Diesel Mechanic ) from 0800 Hours to 1600 Hours for operation and maintenance of Sewage Disposal installation located at Sanjivani comprising of following equipments/ machines/ pump sets including testing and operation of valves and allied work including saturdays/ sundays/ holidays for operation of system as and when required and also to carry out minor repairs/ servicing/ rectification of faults as and when required to all machines/ Equipments and valves to ensure 100% serviceability of plants and removing Scaling Materials, mud Materials grass/surface dressing from surrounding area complete all as specified :- (11x30x1=330 shifts). Note for item No 04 & 05 (a) Rate quoted shall deemed to include quaterly inspection & maintenance of above mentioned machine by OEM or service personal authorized by the OEM. (b) Record /daily logsheet shall be maintained in log book by operator and it should approved by the Engineer-in-Charge. (c) The operator shall be responsible for checking and maintaining the water parameters like BOD < 10mg/Lit, COD < 150 mg/Lit, P.H 5.5-8.5, E - Coil from count < 1000 MPN/100 ml, required chlorine 0.5, TSS < 100 mg /Lit , Oil and grease < 10 gm/Lit and the same shall be recorded and intimated to Engr-in-charge. (d) Daily cleaning of floor area and maintaining a good and hygeinic sanitation around the installation. (e) All stationery items such as registers, log books etc should be provided by the contractor. (f) The contractor shall be responsible for getting the STP water samples once a month by an NABL approved water testing laboratory and the test result to be submitted monthly as directed by the Enigneer-in -charge. (g) Non providing of operator in a day by the contractor shall invite penalty of Rs 5000/- per day from his due amount . (h) Labour for cleaning of sludge bed as and when required and disposal of sludge outside Naval Base( Labour for cleaning of sludge bed and disposal shall deemed to be included under the unit rate quoted.
Supply and fix gun metal fire hydrant 63 mm dia, single headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete, all as specified and as directed. Make : Essel/ Fire marshal/ SRI/ Ever safe/ Newage/ Aadi/ Fire cool
Supply and fixing gun metal fire hydrant 63 mm dia, double headed with flanged inlet and instantaneous out let on the existing stand post with brass nipple, including necessary bolts, nuts and washers including taking down unserviceable old one complete, all as specified and as directed. Make : Essel/ Firemarshal/ SSRI/ Ever safe/ Newage/ Aadi/ Fire cool.
Supply and fix in repair Hose Male S/S coupling 63mm dia for hydrant valve ISI makred including taking ddown old unserviceable one. Make : Essel/ Firemarshal/ SSRI/ Ever safe/ Newage/ Aadi/ Fire cool
Supply and fix in repair Hose Female S/S coupling 63mm dia for hydrant valve ISI makred including taking ddown old unserviceable one. Make : Essel/ Firemarshal/ SSRI/ Ever safe/ Newage/ Aadi/ Fire cool
Supply and fix first aid hose reel, wall mounted swinging type complete with drum, bracket, globe valve/ stop cock of size 19 mm dia, 30 mtr long high pressure hose reel tubing with branch pipe gun metal shut off nozzle including taking down unserviceable old one , all as specified and as directed. Note :- Hose reell shall be as per IS 884 and hose tubing as per IS 8090 ; Make : Eversafe/Newage/SRI/Mahveer
Supply and fix, 15 Mtr long rubber lined woven jacketed hose pipe 63 mm dia, type A (Reinforced rubber lined) as per IS 636 with necessary instantaneous spring lock type coupling at the ends to match with landing valve/hose pipe/branch pipe with gun metal male and female coupling conforming to IS 903 all as specified and as directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
Supply and fix fabricated MS hose cabinet, made of 18 gauge MS sheet 800mm X 600mm X 250mm double door with 4 mm thick glasses and door frame made of 16 gauge MS sheet painted fire red out side brilliant white inside and including taking down unserviceable old one , all as specified and as directed
Supply and fix 63 mm dia branch pipe gun metal instantaneous inlet and made 15 mm bore nozzle short all as specified and as directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
Supply and fix, Fire brigade inlet connection 4 way valve ISI marked including taking down unserviceable old one , all as specified and as directed. Make : Newage/Essel/SRI/Ever Safe/Aadi/CRC
Supply and fix , in replacement of Pressure switch Universal type all as speficied and directed. Make : Danfoss / Indfoss or equivalent approved make.
Supply and fixing, in replacement of Pressure Gauge, 100mm dia, 0 - 14 Kgs rating complete all as spcified and directed. Make : H Guru or equivalent approved make.
Supply and fix, in replacement of 500 litres capacity ISI marked Rotational Moulded polyethylene water stroge tank (cylinderical Vertical with Close top ) hosisted and fixed in position all as Specified and directed Make : Aqua Tech / Syntex
Supply and fixing, in replacement of 150mm bore Stainless steel stainer for foot valve of suction pipe ,all as specified and directed.
Supply and fixing, in replacement of 100mm bore Stainless steel stainer for foot valve of suction pipe ,all as specified and directed.
Supply and fixing in replacement of 150mm bore of Cast Iron, butter fly valve , all as specified directed. Make : AUDCO / C&R / INTERVALE / KARTHAR
Supply and fixing in replacement of 100mm bore of Cast Iron, butter fly valve , all as specified directed. Make : AUDCO / C&R / INTERVALE / KARTHAR
Supply and fix, 150mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , all as specified and as directed. Make :- Kirloskar / Bir / Leader / KARTHAR
Supply and fix, 100mm bore cast iron Non Return valve with by pass arrangement including taking down unserviceable old one , all as specified and as directed. Make :- Kirloskar / Bir / Leader / KARTHAR
Supply and fixing, in replacement 150 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR
Supply and fixing, in repalcement of 100 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR
Supply and fixing in repalcement of 80 mm bore Cast iron sluice valve with flanged ends of type PN 1.6 conforming to IS 14846 with cast iron wheel and brass spindle , all as specified and directed Make : AUDCO / C&R / INTERVALE / KARTHAR
Supply and fixing , 100mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubedall as specified and directed. Make : AUDCO / C&R / INTERVALE / KARTHAR
Supply and fixing , 80mm Cast iron Foot valve including taking down from the suction side of pumpset from the sump and making good the distrubed. all as specified and directed Make : Normex/Audco .
Supply and fix, 50mm gun metal, gate valve with iron wheel head, screwed both ends for iron pipe including taking down unserviceable old one all as specified and as directed. Make : Sankti/ NVI/ zew/ Atom.
Supply & fix , in replacement of three pole power contactor MNX 140, 2NO+2NC for main pumpset all as specified and as directed. Make : L & T or equivalent as approved by GE
Supply & fix, in replacement of three pole power contactor MNX-110, 2NO+2NC power contactor MNX 110 for Main pumpset all as specfied and as directed. Make : L & T or equivalent as approved by GE
Supply & fix, in replacement of three pole power contactor MNX-22, 1NO+1NC for pumpset all as specfied and as directed . Make : L & T or equivalent as approved by GE
Supply & fix Electronic timer type ST 100 all as specified. Make : L & T or equivalent as approved by GE
Supply & fix , in replacement of Push button with indicator ( set of three R Y B ) for panels all as specified and directed Make : L&T or equivalent approved by GE
Supply and Fix , in replacement 12 Volt 90 AH Self Charging Battery for Diesel Pump set , all as specified and as directed Make : Cummins/Exide or equivalent approved by GE
Supply and laying ,of CPVC pipe inner diameter 150 mm with CPVC schedule 40 pipes & plain schedule 80 fittings on walls / ceiling or laying in floors and jointed with CPVC primer & CPVC solvent cement including taking down unserviceable old one, all as specified and directed..
Supply and laying ,of CPVC pipe inner diameter 100mm with CPVC schedule 40 pipes & plain schedule 80 fittings on walls / ceiling or laying in floors and jointed with CPVC primer & CPVC solvent cement including taking down unserviceable old one, all as specified and directed..
Supply and laying ,of CPVC pipe inner diameter 75 mm with CPVC schedule 40 pipes & plain schedule 80 fittings on walls / ceiling or laying in floors and jointed with CPVC primer & CPVC solvent cement including taking down unserviceable old one, all as specified and directed..
Supply and laying , Ductile Iron Pipes 150mm bore centrifugally cast (spun) including jointing in standard length, with flanged ends, Class "K9" conforming to IS 8329-2000 (latest version) in any length laid in trenches including taking down unserviceable old one , all as specified and directed. Make : Sri Pipes / Jindal / Kejriwal
Supply and laying , Ductile Iron Pipes 100mm bore centrifugally cast (spun) including jointing in standard length, with flanged ends, Class "K9" conforming to IS 8329-2000 (latest version) in any length laid in trenches including taking down unserviceable old one , all as specified and directed. Make : Sri Pipes / Jindal / Kejriwal
Supply and laying, 150 mm bore GI tubing Heavy grade with all fittings laid in trenches or fixed to walls and ceilings or laying in floors, including taking down unserviceable old one , all as speciifed and as directed. Make : Jindal / TATA
Supply and laying, 100 mm bore GI tubing Heavy grade with all fittings laid in trenches or fixed to walls and ceilings or laying in floors, including taking down unserviceable old one , all as speciifed and as directed. Make : Jindal / TATA
Supply and laying, 80 mm bore GI tubing Heavy grade with all fittings laid in trenches or fixed to walls and ceilings or laying in floors, including taking down unserviceable old one , all as speciifed and as directed. Make : Jindal / TATA
Supply & fix, DI fittings (pressure class K-9) such as bends, (any type, radius and angle), Tapers any type (straight bend, increasing, decreasing or double socket etc) Tee piece single branch "Y" junction double branch, cross (all socket or socket and spigot) collars, caps and plugs of size upto 150mm bore confirming to IS 9523-2000 including taking down unserviceable old one , all as specified and directed.
M & L MS Framed / Fabricated work such as Valve chamber covers, Static Tank Cover, Base frames for pumpsets , Protection covers for Pumpsets / Panel Boards, Staging for Water tanks, ladders, etc. complete all as specified.
M & L for constructing of brick masonary pits of internal dimensions 900 x900 x900mm ( bottom PCC floor of the pit should be minimum 30 cms below the bottom surface of sluice valve flange to provide sufficient working space) , bottom floor of the pit be constructed in PCC (1:3:6) 15 cms thick with 40 mm stone aggregate, inner and exposed surfaces and bottom floor of the pit should be plastered in CM (1:4) 15 MM thick. The sluice valve and other fittings should be housed in center of the pit. the vertices of the pit should in right angle and champhered .The top cover of the pit will be made out of MS sheet min 5mm thick witth angle iron frame made out of MS angle 50mm x50 mmx 6 mm with galvanised steel hindges two nos ,and locking arrangements, duly painted with two coats of water resistant synthetic enamelled paint over one coat of red oxide all as specified and as directed.
Servicing and repairs to cast iron sluice valve of 150 mm size by removing spindle, gate and check nut, cleaning and refixing new gland packing and rubber gasket complete all as specifed and directed
Servicing and repairs to cast iron sluice valve of 100 mm size by removing spindle, gate and check nut, cleaning and refixing new gland packing and rubber gasket complete all as specifed and directed
M & L 150mm bore C I pipes with flanged end, centrifugaly cast, class "A" in any length, laid in trenches including taking down old unserviceable one, all as specified and directed Make : Jindal / TATA
M & L 100mm bore C I pipes with flanged end, centrifugaly cast, class "A" in any length, laid in trenches including taking down old unserviceable one, all as specified and directed Make : Jindal / TATA
M&L General Servicing and Maintenance to diesel engine driven pump / fuel ijection pump of capacity 85 HP including B check and service as per manufactures recommendation ,overhauling including repalcement of oil filter ,air filter ,gland packing ,diesel filter with replace ment of O rings ,Engine Oil and toping up of Coolant up to required level etc which ever be required to making 100 % serviceabiltiy of the engine complete all as specified and as directed
M&L General Servicing and Maintenance to diesel engine driven pump / fuel ijection pump of capacity 75 HP including B check and service as per manufactures recommendation ,overhauling including repalcement of oil filter ,air filter ,gland packing ,diesel filter with replace ment of O rings ,Engine Oil and toping up of Coolant up to required level etc which ever be required to making 100 % serviceabiltiy of the engine complete all as specified and as directed
M&L General Servicing and Maintenance to diesel engine driven pump / fuel ijection pump of capacity 56 HP including B check and service as per manufactures recommendation ,overhauling including repalcement of oil filter ,air filter ,gland packing ,diesel filter with replace ment of O rings ,Engine Oil and toping up of Coolant up to required level etc which ever be required to making 100 % serviceabiltiy of the engine complete all as specified and as directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 150 HP and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 100 HP and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 70/75 HP and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 60/50 HP and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 40 HP and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 15 HP and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed
Material and labour for disconnecting of suction and delivery pipe and electric connections, from three phase centrifugal pump sets motor of capacity 12.5 HP and dismantling the pump sets complete from the foundation, strip opening the unserviceable motor at site to located the fault and transporting to the local work shop . Strip opening the motor and cutting/removing burnt out winding and rewinding the motor with as per existing original wire guage super enammelled copper wire including high quality 'F' class insulating material with heat resistant sleeves, sealing compound and varnishing and heating the stator upto varnish fully dry and testing the motor at work shop to the satisfaction of Engr-in-charge. Coupled the motor with pump and installed at site as per existing position.Testing the pump set after completion of work all as specified and directed
M & L Overhauling of Fire fighting pump, Electric driven pumpset of 3 Phase, 415 volt, of any size / capacity by cleaning, varnishing, heating, assembling, refixing in position and pump side replacing of stainless steel sleeve, gland packing, greasing etc and testing complete all as specified and as directed.
M & L Diconnecting Suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump of capacity 150 HP from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work complete all as specified and directed.
M & L Diconnecting Suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump of capacity 100 HP from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work complete all as specified and directed.
M & L Diconnecting Suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump of capacity 70/75 HP from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work complete all as specified and directed.
M & L Diconnecting Suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump of capacity 60/50 HP from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work complete all as specified and directed.
M & L Diconnecting Suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump of capacity 40 HP from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work complete all as specified and directed.
M & L Diconnecting Suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump of capacity 15 HP from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work complete all as specified and directed.
M & L Diconnecting Suction and delivery pipe lines from unserviceable Electric driven 3 phase centrifugal pump of capacity 12.5 HP from motor and opening the pump , cleaning , replacing the worn out part like - ball bearing , gun metal bush , pump shaft repair by lath, repairing of impeller by grinding / polishing ,water sealant of any type and necessary gland packing etc. which ever be required to making 100 % serviceable of pump sets coupled with motor and installed at site as per existing including testing after complete repairs of work complete all as specified and directed.
Disconnecting the three phase electric supply from panel board and taking out the burned wireing of panel board and unserviceable spare part like contactor ,relays, timer , push botton, NO/NC volts coil and thermal load relays etc and re-wring the panel board with new required size of wire and acessories which be required to make 100 % serviceability suitable for starter panel for pump sets
M & L, Cast Iron Fittings upto 150mm dia such as bends (cany type, radius and angle), tappers any type (straight, bend, increasing or double socket etc) tee pieces single branch "Y" junction, double branch, cross (all sockets or socket and spigot) collars, caps and plugs including taking down unserviceable old one all as specified and as directed
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre depth and getting out in soft / loose soil for laying of cable complete all as specified.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick in soft/ loose soil , complete all as specified.
Removing excavated soil to a distance not exceeding 50 metre and depositing where directed at a level, not exceeding 1.5 metre above the starting point , complete all as specified.
M&L Preparing surfacaes and applying two coat of synthetic enamel paint to outer side of the existing feeder pillar board, panel board and fire fightings equipments, pipe lines using spray gun and compressor complete all as specified. Make : Asian Paints / Shalimar / Nerolac / Berger Paints
M & L Cleaning of Fire Fighting Static Water Tank of capacity 1,00,000 / 50,000 Gallon by providing pumping set & removing all muds, stones, other foregin materials etc, washing with bleaching powder and applying a coat of colour wash (internal & external surfaces) including repairing & painting of tank cover made of wire mesh and angle iron frame with synthetic enamel paint and writing the words " TANK NO, CLEANED ON, NEXT DUE ON, TANK CAPACITY " in capital letters of suitable size on outside visible place of Static tank with synthetic enamel white paint over black ground complete all as speficied and as directed.
Supply, Install, testing and commissioning of Air Cushioning Tank (Air vessel) of 250mm dia and 1000mm high with dished top, made of minimum 6mm thick MS pipe /plate complete with 20mm dia. Brass air valve (ball type), 20mm dia stop valve, pressure gauge with brass stop cock, nipple tees elbows and all accessories complete incliding taking down old unserviceable tank complete all as directed.
M & L Repair / replacement of worn out Gland Packing of pump set / sluice valves / hydrants any make / metal / size including washers of any shape / size to avoid water leakage as indicated including taking out old one complete all as specified and directed.
Comprehensive maintenance of addressable fire alarm system installed INHS Sanjivani Hosptal including, testing with SMOKE DETECTER TESTER (AEROSOL) functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed: Make : Siemens. (a) Microprocessor based control Panel 8 Loop - 01 No. (b) Multi Sensor - 700 Nos. (c ) Fire alarm hooters - 50 Nos. (d) Manual call points - 43 Nos. (e) Repeater Panels - 10 Nos. (f) Heat detecter - 18 Nos. (g) 12 AH Battery - 02 Nos. (h) Response Indicator - 120 Nos. (i) Electronic siren - 01 No Note for item Nos 78 to 89 (i) Contractor Shall Maintain all the Documents and Produce to the Concernt Engineer in charge as and when required /preparation of RAR (ii) Contractor shall give the Demo and training for all duty staffs about the fire alarm System. The unit rate quoted is deemed to be included for the Same (iii) Spares required for replacement, shall be measured seperately as 'Supply only' under respective items.
Comprehensive maintenance of addressable fire alarm system installed at Sea Harrier complex (NIAT) including, testing with SMOKE DETECTER TESTER (AEROSOL) functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed: Make-Edward EST3. (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Repeater panel - 1 No . (c ) Smoke detectors - 72 Nos. (d) Fire alarm hooters - 06 Nos . (e) Manual call Points - 4 Nos. (f) UPS - 02 Nos. (g) Heat and Smoke detecters - 06 Nos. (h) 7 AH Battery - 02 Nos. (i) Response Indictor - 20 Nos. (j) Isolator - 06 Nos
Comprehensive maintenance of addressable fire alarm system installed at MO (K) including, testing with SMOKE DETECTER TESTER (AEROSOL) functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed: Make- Edward. (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Smoke detectors - 46 Nos. (c) Fire alarm hooters - 05 Nos. (d) Manual call point - 10 Nos. (e) Isolator module - 02 Nos. (f) 7 AH Battery - 02 Nos.
Comprehensive maintenance of addressable fire alarm system installed at ND School including, testing with SMOKE DETECTER TESTER (AEROSOL) functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed: Make- Edward (a) Microroprocessor based control Panel 1 Loop - 01 No. (b) Repaeter Panel - 01 No. (c) Smoke Detectors - 54 Nos (d) Fire alarm hooters -06 Nos. (e) Manual call Points- 3 Nos. (f) Heat & Smoke detector - 06 Nos. (g) 7 AH Battery - 02 Nos (h) Isolator - 04 Nos
Comprehensive maintenance of addressable fire alarm system installed at NIAT including, testing with SMOKE DETECTER TESTER (AEROSOL) functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed. Make : Edward. (a) Microprocessor based control Panel 4 Loop - 01 No. (b) Mulit Sensor detector - 150 Nos. (c) Fire alarm hooters - 12 Nos. (d) Manual call Points - 12 Nos. (e) Isolator module - 60 Nos. (f) Response Indicator - 40 Nos. (g) Heat detector - 05 Nos. (h) Repeater Panel - 01 No . (i) 7 AH Battery - 02 Nos.
Comprehensive maintenance of addressable fire alarm system installed at Sagarika Auditorium including, testing with SMOKE DETECTER TESTER (AEROSOL) functionality of all components, cleaning all device , replacement of defective spares / components, comprising of following all as specified and directed. Make- GST (a) Microroprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel - 01 No. (c) Muilt Sensor Detectors - 140 Nos (d) Sounder Cum Strobe - 10 Nos. (e) Manual call Points- 10 Nos. (f) Siren - 10 Nos. (g) 7 AH Battery - 02 Nos (h) Isolator - 05 Nos (i) Beam Detectors - 06 Nos (j) Sprinkler Bulb - 97 Nos
Comprehensive maintenance of addressable fire alarm system installed at INHS Sanjivani including testing functionality of all components, testing of smoke detector ( using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) , and cleaning of all devices, replacement of defective spares / components, comprising of following all as specified and directed. Make : Siemens. (a) Microprocessor based control Panel 8 Loop - 01 No. (b) Multi Sensor - 700 Nos. (c ) Fire alarm hooters - 50 Nos. (d) Manual call points - 43 Nos. (e) Repeater Panels - 10 Nos. (f) Heat detecter - 18 Nos. (g) 12 AH Battery - 02 Nos. (h) Response Indicator - 120 Nos. (j) Electronic siren - 01 No
Comprehensive maintenance of addressable fire alarm system installed at Sea Harrier complex (NIAT) including testing functionality of all components, testing of smoke detector ( using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) , and cleaning of all devices, replacement of defective spares / components, comprising of following all as specified and directed. Make-Edward EST3. (a) Microprocessor based control Panel 2 Loop - 01 No. (b) Repeater panel - 1 No (c ) Smoke detectors - 72 Nos. (d) Fire alarm hooters - 06 Nos (e) Manual call Points - 4 Nos. (f) UPS - 02 Nos. (g) Heat and Smoke detecters - 06 Nos. (h) 7 AH Battery - 02 Nos. (i) Response Indictor - 20 Nos. (j) Isolator - 06 Nos
Comprehensive maintenance of addressable fire alarm system installed at MOC (K). including testing functionality of all components, testing of smoke detector ( using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) , and cleaning of all devices, replacement of defective spares / components, comprising of following all as specified and directed. Make- Edward. (a) Microprocessor based control Panel 1 Loop - 01 No. (b) Smoke detectors - 46 Nos. (c) Fire alarm hooters - 05 Nos. (d) Manual call point - 10 Nos. (e) Isolator module - 02 Nos. (f) 7 AH Battery - 02 Nos.
Comprehensive maintenance of addressable fire alarm system installed at ND School. including testing functionality of all components, testing of smoke detector ( using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) , and cleaning of all devices, replacement of defective spares / components, comprising of following all as specified and directed. Make- Edward. (a) Microroprocessor based control Panel 1 Loop - 01 No. (b) Repaeter Panel - 01 No. (c) Smoke Detectors - 54 Nos (d) Fire alarm hooters -06 Nos. (e) Manual call Points- 3 Nos. (f) Heat & Smoke detector - 06 Nos. (g) 7 AH Battery - 02 Nos (h) Isolator - 04 Nos
Comprehensive maintenance of addressable fire alarm system installed at NIETT including testing functionality of all components, testing of smoke detector ( using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) , and cleaning of all devices, replacement of defective spares / components, comprising of following all as specified and directed. Make- Edward. (a) Microprocessor based control Panel 4 Loop - 01 No. (b) Mulit Sensor detector - 150 Nos. (c) Fire alarm hooters - 12 Nos. (d) Manual call Points - 12 Nos. (e) Isolator module - 60 Nos. (f) Response Indicator - 40 Nos. (g) Heat detector - 05 Nos. (h) Repeater Panel - 01 No (i) 7 AH Battery - 02 Nos.
Comprehensive maintenance of addressable fire alarm system installed at Sagarika Auditorium including testing functionality of all components, testing of smoke detector ( using insence stick), heat detector (using hot air blower), beam detector (using obstracle method) , and cleaning of all devices, replacement of defective spares / components, comprising of following all as specified and directed. Make- GST (a) Microroprocessor based control Panel 1 Loop - 01 No. (b) Repeater Panel - 01 No. (c) Muilt Sensor Detectors - 140 Nos (d) Sounder Cum Strobe - 10 Nos. (e) Manual call Points- 10 Nos. (f) Siren - 10 Nos. (g) 7 AH Battery - 02 Nos (h) Isolator - 05 Nos (i) Beam Detectors - 06 Nos (j) Sprinkler Bulb - 97 Nos
Reprograming of Existing fire alarm system installed at Various Locatioin including loope Checking, Changing of Device Location Name and Address of the Room and preparing as build Drawing complete all as specified and directed
Supply only addressable type multi sensor detector with smoke & Heat combination all as specified and directed. Make: Edward / GST/ Honey well / morley / Siemens.
Supply only addressable Sounder cum- storb all as specified and directed. Make: Edward/GST/Honeywell/Morley/Siemens.
Supply only addressable remote response indicators all as specified and directed. Make : Edward/GST/Honey well / Morley / Siemens.
Supply only addressable Manual call point resettable type all as specified and directed. Make : Edward/GST/Honey well/ Morley/Siemens.
Supply only addressable Monitor module for Beam detector all as specified and directed. Make : Edward/GST
Supply & Fix Sprinkler Bulb, 20mm dia, quick response with extended covereage type 57 degree Celsius Pendent / Side wall Type
Supply only addressable type heat detector with base, rate of temperature rise as per IS-2175 all as specified and directed. Make : Honey well / Morley.
Supply only addressable Beam master detector with transmitter and receiver all as specified and directed. Make : Honey well / Morley.
Supply only Flame detector all as specified and directed. Make : Honey well / Morley.
Supply only addressable short circuit isolator all as specified and directed. Make : Honey well / Morley
Supply only 12 V 7 AH Battery all as specified and directed. Make : Exide /Amaron/Panasonic.
Supply only 12 V 12 AH Battery all as specified and directed. Make : Exide /Amaron/Panasonic.
Supply only 1000 VA UPS all as specified and directed. Make : APC /Intex/Su-Kam / V-guard.
Supply only addressable Fire alarm Repeater panel all as specifed and as directed. Make : Edward / GST / Honey well / Siemens
Supply only addressable Fire alarm control panel complying with BSEN54/UL- 1/ 2 / 4 loop panel of capacity from 126 detectors & 126 modules all as specified and directed. Make : Edward/GST/ Honey well/Siemens
Supply only 2 core1.5 sq mm PVC insulated unsheathed FRLS multi stranded copper conductor cable all as specified and as directed. Make : Polycab/Havells/Finolex/Indoasian/National
M & L Cleaning of 3 mtr long x 0.40 mtr dia Strainer fabricated with aluminium stainer to suction line having 1200 holes to the strainer of suction line Twice a year includes dismantling the suction line and lifting it , cleaning the foot valve , scrubbing the complete stainer including 1200 holes with suitable liquid properly and than lowering back for refixing the stainer into sea water with MS angle arms and 02 hooks provided to the strainer for lifting/ lowering the strainer to the suction line and to the pump set alongwith foot valve inside the lowered stainer complete all as specified and directed complete.
AAG INDIA PVT LTD
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .