Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹29.5 LAccepted-AOC 32 GOLA MAHAL P O BARRACKPORE DIST NORTH 24 PARGANAS PIN 700 120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹29.5 L Quoted ₹30.6 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹33.4 L+₹2.8 L (9.29%)Rejected-Finance | ₹33.4 L+₹2.8 L (9.29%) | L2 | Rejected-Finance Not the lowest bidder |
| 3 | L3₹34.8 L+₹4.2 L (13.8%)Rejected-Finance 106 1 RAJA RAMMOHAN SARANI KOLKATA 700 009 | KOLKATA | WEST BENGAL | 700009 | ₹34.8 L+₹4.2 L (13.8%) | L3 | Rejected-Finance Not the lowest bidder |
| 4 | L4₹34.9 L+₹4.4 L (14.3%)Rejected-Finance | ₹34.9 L+₹4.4 L (14.3%) | L4 | Rejected-Finance Not the lowest bidder |
| 5 | L5₹35.1 L+₹4.5 L (14.7%)Rejected-Finance | ₹35.1 L+₹4.5 L (14.7%) | L5 | Rejected-Finance Not the lowest bidder |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
15 Sept 2020, 6:00 pmClosed
GE Barrackpore
Office of the Garrison Engineer Barrackpore, Kolkata-700120
REPAIR AND REPLACEMENT OF CERTAIN LIGHT FITTINGS AND FIXTURES CONVERTED INTO LED LIGHTS FITTINGS AND FIXTURES AND INCLUDING INTERNAL WIRING, CEILING FANS, EXHAUST FANS, WALL MOUNTED FANS, GEYSER, DB, MCB ETC IN OFFRS MD ACCN AND OTM ACCN, JCOS/ORS A
2020_MES_372352_1
8435/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Barrackpore
Refer to tender documents
3 documents required · 3 mandatory
₹500
GE Barrackpore
₹60,000
Yes
16 Oct 2020
27 Aug 2020
17 Sept 2020
27 Aug 2020
15 Sept 2020
10 Sept 2020
Amount
M&L for sub main wiring (surface) complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through in and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as bend, tee, elbow, Short pieces etc in wall/roofs/floors and including one run of 6 sqmm (green colour) single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty complete all as specified and directed after taking down existing sub-main wiring of any type/size from wall and making good disturbed surface. (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of 25mm dia PVC conduit shall be measured as one unit) (Make : FINOLEX/NICCO/HAVELLS for Copper cable and PRESTOPLAST/FINOLEX/PLAZA/PRECESSION for PVC conduit and conduit accessories as approved)
M&L for sub main wiring (surface) complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 20 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty complete all as specified and directed after taking down existing sub-main wiring of any type/size from wall and making good disturbed surface. (Note : -Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of 20mm dia PVC conduit shall be measured as one unit) (Make : FINOLEX/NICCO/HAVELLS for Copper cable and PRESTOPLAST/FINOLEX/PLAZA/PRECESSION for PVC conduit and conduit accessories as approved)
Taking down carefully copper/aluminium point wiring (light, fan, bell, socket or power) complete, including fixtures and fittings such as switches, ceiling roses, holders, regulators, sockets, tube light fittings and including making good the disturbed surfaces to match with the existing surfaces and applying white/ colour wash/distemper after applying putty for smooth finish surface complete all as specified and directed.
M&L for surface point wiring complete with two single core 1.5 sqmm PVC insulated, FR-LSH type, ISI marked, conforming to IS-694/1990 unsheathed, multistranded, single core, copper conductor cable 1100 volts grade colour code cables drawn through and including PVC casing and caping of size 20mm, ISI marked (medium grade) as required at site with all accessories such as Tee, corner, over laping, connector etc on walls / roofs / ceiling etc. flush mounting MS box with top, bottom, side/back wall knockout for casing & caping entry from any direction made out of 1.60mm thick and 50mm depth suitable for fixing of bakelite laminated top cover 3mm thick, blanking plate, numbers of switches, sockets, fan regulators, red colour indicator, blank plates etc as approved coloures accessories of suitable and including 1.5 Sqmm PVC insulated multistranded FR-LSH type unsheathed (Green colour), single core cable with copper conductor cable as earth continuity conductor and connecting to common earth dolly and including making good the disturbed surfaces to match with existing surfaces and applying white/ colour wash/distemper after applying putty for smooth finish surface for the following complete all as specified and directed :- (Note:- All necessary accessories such as top cover plate, blank plate, MS box, screws, washers etc are to be used of same make/brand only and shall be deemed in to included in quoted rate only.) (Make : FINOLEX/NICCO/HAVELLS for Copper cable and PRESTOPLAST/FINOLEX/PLAZA/PRECESSION for PVC casing and caping including accessories)
One light point controlled by one switch .
One light point controlled by two Nos two way switches .
One fan point controlled by one switch and one regulator.
One 3 pin 5/15 amps socket outlet point on same board.
One bell/buzzer point controlled by one bell push.
One 3 pin 5/15 amps socket outlet point on independent board.
All as per Item No.4.00 here-in-before but point wiring with 2.5sqmm PVC insulated multistranded flexible unsheathed copper conductor FR-LSH and earth conductor of size 2.5 sqmm PVC insulated multistranded flexible copper conductor FR-LSH of one 3 pin, 15 Amps socket outlet on independent board complete all as specified and directed complete .
S&F for LED 18 Watt light fittings suitable for LED T8 lamp, pre wired including necessary electric connection with required size copper cable after and including taking down any type of old tube light fittings complete all as specified and directed . (Make : Crompton Greaves cat No : DMLN1LT8-16/ Havells cat No : REGALBATTENT8UPTO1X18WDSBSWH as approved)
S&F for 18 watt linear LED T8 tubular lamp with extruded aluminium body / polycarbonate diffuser with inbuilt driver complete including taking down old unserviceable lamp complete all as specified and directed. (Make: Crompton Greaves Cat No LTT8-20 /Havells Cat No PHOTONULTRA1213T8SSTL18WLED865SPC as approved)
S&F for angle lamp holder, insulated body with back plate for batten fittings in and including LED lamp 12 watts complete all as specified and directed. (Make: Philips/Havells/Crompton Greaves as approved)
S&F for stepped type (0-4/5 step) electronic fan regulator for ceiling fan 1200 mm, 240 Volts, 100 Watts to 120 watts single pole, ISI marked including connecting, testing complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for call bell, AC, 230 Volts single pole, multi music type ISI marked complete as in repair all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for bell push switch, single pole, one way, flush type, 6 Amps, 240 volts, ISI marked complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 Amps, 240 volts, ISI marked, AC complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for switch piano flush button single pole, one way, 5 amp, 240 volts, AC, ISI marked complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for switch piano, flush type, single pole, two way, 5/6 Amps, 240Volts, AC, ISI marked complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for socket out let, flush type, 2 in 1, 3/5 pin, 5/6 and15/16 Amps, 240 volts, AC, ISI marked complete as in repair all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for switch piano flush button single pole one way 15/16 amp 240 volts, AC, ISI marked complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for ceiling rose , surface bakelite 65X50mm, three terminal, PVC/polycarbonate body complete all as specified and directed. (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for PVC round/square blocks suitable to fixing tube light fittings and ceiling roses complete all as specified and directed . (Make:Anchor (Penta)/Havells/Legrand as approved)
S&F for fluorescent tube light lamp 36 Watt 4 feet long, suitable for 36/40 Watt tube light fittings complete as in repair all as specified and directed. (Make: Philips/Havells/Crompton Greaves as approved)
S&F for powder coated sheet metal enclosure metal door 415 volts AC,TPN distribution board 4 way suitable for flush mounting with 100 amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100 Amps, MCB TPN/DP and MCB SP, 10KA as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface and colour coat complete as in repair all as specified and as directed. (Make:- Legrand cat No. 5076 70 4 way / Hager Cat No.VYT04DD/ L&T Cat No. DBTPE004DD as approved)
S&F for powder coated sheet metal enclosure acrylic door 240 volts AC, SPN distribution board 8 way for flush mounting with 100amps copper busbar, neutral bar, earth bar and MCB incomer of rating upto 100Amps, MCB SPN/DP and MCB SP as outgoing and complete connecting cable links with top and bottom removable gland plate with IP 43 DBs protection and including making good the disturbed surfaces to match with existing surface & colour coat complete as in repair and all as specified and directed. (Make: Legrand Cat No. 5076 21 8 way / Hager cat No.VYS08G / L&T Cat No.DBSPN008DD as approved)
S&F for MCB, four pole, 63 Amps, 'C' Series, 240 Volts, 50Hz, ISI marked complete as in repair all as specified and directed. (Make: L&T Cat No.BB40630C/Legrand Cat No. 4087 02 or equivalent of Havells as approved)
S&F for MCB, double pole, 40 Amps, 10 KA, "C" series, AC, 240 Volts, 50Hz, ISI marked complete as in repair all as specified and directed. (Make: L&T Cat No. BB20400C/Legrand Cat No. 4086 37 or equivalent of Havells as approved)
S&F for MCB, SP, 6 Amps to 32 Amps , 'C' series, 240 Volt, 10KA, 50 Hz, ISI marked complete as in repair all as specified and directed (Make: L&T /Havells/Legrand as approved)
M&L for earthing complete with galvanised steel earth plate electrode 600mmX 600mmX 6mm thick buried directly in ground vertically ( earth pit not less than 2.25 meters deep below ground level) with top edge of plate not less than 1.5 metres below ground level, connected to and including galvanised iron wire 4 mm dia and light grade protection pipe of 15 mm dia from earth electrode up to test point or up to 7.5mtr whichever is less by means of GI bolts, nuts, check nuts and washers all as per electrical plate No 5 of SSR Pt-I and GI watering pipe of 20 mm dia medium grade, GI funnel with wire mesh including charcoal, salt packed all around the earth electrode plate in layers, PCC earth pit chamber (1:3:6) type C1, of size 45X 45X 45 CM, RCC cover (1:2:4) type B1 of size 45X45X6 CM, excavation/earth work in any strata and returning filling, removal of surplus soil and testing/test point for required value including removing old item complete all as specified and directed. (Galvanised strip upto 7.5m including testing consider in this item).
Taking down existing electric meter carefully from the meter box and re-fixed the same in the existing or new location complete all as specified and directed.
M&L for fixing of PVC insulated FR-LSH cable with multistranded copper conductor 1100 volt grade of size 6 sqmm for connection from MCB to electric meter by using clips in meter box complete all as specified and directed after taking down existing cable of any type and any size. (Note : Two run of 6Sqmm copper cable shall be measured as one unit length) (Make: Havells/Finolex/Nicco as approved)
M&L for 1100 KV grade heavy duty cable PVC insulated aluminium stranded conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hanger not more than 1 mtr apart including 4 mm suspension wire one twin core cable flat or circular of size 16 Sq mm multi stranded conductor complete all as specified and directed after taking down existing cable of any type and any size. (Make: Havells/Finolex/Nicco as approved)
S&F for house service bracket (hook type) complete with 3.0m long GI pipe 40 mm dia (medium grade), two Nos 90 degree bends, mild steel hook and stay or guy complete as in repair all as specified and directed. (Make: Jindal/Bansal/Prakash Surya as approved)
S&F for industrial bulk head luminaries IP65 with heat resistance glass cover and powder coated wire guard including 10W LED lamp and fixing materials such as clamps, nuts, bolts, washers etc complete as in repair all as specified and directed. (Make : Crompton Greaves cat No LBHE-10-CDL/ Havells Cat No. RUGBYNEONFT10WLED860SSYMTOPC as approved)
Supply, fabricated and fixing of street light bracket made out of GI pipe 1.0 Mtr long, 40mm dia medium grade bent to shape as directed including clamps made out of 40 mm x 6 mm flat for fixing bracket suitable for steel tubular poles including nuts and bolts, washers and other connected items of required size including painting with one coat of aluminium paint over a coat of red oxide/primer complete after taking down old unserviceable bracket all as specified and directed. (Make: Jindal/Bansal/Prakash Surya as approved)
S&F for LED street light fittings Indus series IP-65 powder coated pressure die cast aluminium compact high power LED street light with heat resistant toughened glass of capacity 30 watt with LED lamp complete as in repair all as specified and directed . (Make : Crompton Greaves Cat No LSTS-30-CDL/ Havells Cat No ENDURACITYLITEPLATPLUSSL30W757SASYB0PC as approved)
S&F for rectangular blocks closed recessed type made out of 2nd class hard wood fixed of the sizes 30cmX25cmX5cm complete as in repair all as specified and directed
S&F for rectangular blocks closed recessed type made out of 2nd class hard wood fixed of the sizes 25cmX20cmX5cm complete as in repair all as specified and directed
Taking down ceiling fan of 1200/1400 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, overhauling, replacement of bush, bearing, split pin, rubber bush, screws, lock nuts, locking pin etc and marking MES number etc complete all as specified and directed. (Note : Gun metal Bush, bearing are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in quoted rate)
All as per item No 35.00 here in before and including painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint with super glossy finish (grey/brown/white as required) including filling cavities with filler complete all as specified and directed.
Taking down/ dismantling complete ceiling fan of size 1200/1400 mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush, overhauling etc. and making MES number including painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coats of synthetic enameled paint with super glossy finish (grey/brown/white as required) including filling cavities with filler complete all as specified and directed to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed . (Note :- Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in of Item No 37.00).
Supply only ball bearing (ceiling fan) number of 6201/6202/6203/6204 as required. (Make : SKF/NBC/TATA as approved).
Supply only gun metal bush (ceiling fan) as required. (Make : SKF/NBC/TATA as approved).
S&F for condenser or capacitor 2/2.5/3.15 MFD. (metal body) complete as in repair all as specified and directed. (Make : Universal/Sarda as approved)
S&F for mild steel clamp with nuts & bolts suitable for ceiling fans of any make, type and size complete as in repair all as specified and directed.
S&F for rubber reels suitable for ceiling fan 1200mm/1400mm sweep of any type complete as in repair all as specified and directed.
Taking down exhaust fan of 300 mm sweep by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, overhauling, replacement of bush, bearing, split pin, rubber bush, screws, lock nuts, locking pin etc and marking MES number etc complete all as specified and directed. (Note : Gun metal Bush, bearing are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in quoted rate)
Taking down/ dismantling complete exhaust fan of size 225mm to 375mm sweep down rod with its canopies, shackle, condenser housing with its rubber bushes, split pins, unscrewing the body parts of exhaust fan, taking out starter, rotor winding ball bearing, gun metal bush, overhauling etc. and making MES number including painting of ceiling fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coats of synthetic enameled paint with super glossy finish (grey/brown/white as required) including filling cavities with filler complete all as specified and directed to carry out the following repairs :- (a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete exhaust fan fixing only old/new spare parts (i.e.) rubber bush of shackle and condenser housing, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed . (Note :- Ball bearing and Gun metal bush are measured and paid separately as supply only rates and fixing charges for spare parts shall deemed to be included in of Item No 44.00).
Supply only ball bearing for exhaust fan of size 300mm sweep as required. (Make : SKF/NBC/TATA as approved).
S&F for condenser or capacitor (metal body) suitable for exhaust fan of size 300mm sweep complete as in repair all as specified and directed. (Make : Universal/Sarda/Usha as approved)
All as per item No 46.00 here in before and including painting of exhaust fan by scraping/removing old spray paint with brush/emery paper and spray painting with two coat of synthetic enamelled paint with super glossy finish (grey/brown/white as required) including filling cavities with filler complete all as specified and directed.
S&F for louvers shutters complete with nuts, bolts and washers suitable for exhaust fans of size 275 mm to 450 mm sweep complete as in repair all as specified and directed
S&F for twin core twisted copper flexible wire/cable of size 30/0.025 complete as in repair all as specified and directed. (Make: Havells/Finolex/Nicco as approved)
Taking down/ dismantling of defective/rusted storage type hot water Geyser of 50/25 Ltr capacity from different locations by disconnecting inlet/outlet connections and taking out unserviceable parts by unscrewing bolts and nuts, de-scaling/cleaning inner shell, servicing etc. Checking defects, re-assembling and re-installing the Geyser in position, connection and testing complete. (NOTE:- Defects any observed during testing shall be repair and any parts required are measured and paid separately as supply only rate and fixing charges for spare parts shall be deemed to be included in item No.50.00)
Supply only heating element 1.5 KW (ISI marked) cup type/thread type with the provision of thermal cut out as required.
Supply only heating element 2 KW (ISI marked) cup type/thread type with the provision of thermal cut out as required.
Supply only indication lamp (green/red) as required.
S&F for PVC flexible pipes 15mm dia (heavy duty) both end socketed 450mm long for hot/cold water complete as in repair all as specified and directed.
S&F for copper (CP) hot water pipe for geyser, connection with check nut and washer complete as in repair all as specified and directed.
Supply only Inner tank (copper) suitable for geyser 25 Ltrs capacity (apparatus assembly) made copper duly prewired of different make.
Supply only glass wool/mineral wool same as (thermal insulation) for 25 ltrs capacity geyser complete all as specified and directed .
S&F for thermostat (thermal cut out) suitable for geyser to be repaired suitable for 25/35/50 Ltrs capacity complete as in repair all as specified and directed.
Supply only pressure release valve suitable for 25/35/50 Ltrs capacity geyser complete as in repair all as specified and directed.
S&F for PVC insulated and sheathed flexible wire 3 core with copper conductor 4 Sqmm round type, 1100 Volt for geyser complete as in repair all as specified and directed. (Make: Havells/Finolex/Nicco as approved)
M&L for painting of geyser of capacity 25 Ltrs complete in site by scraping/removing old spray paint with brush/emery paper and spray painting with two coats of synthetic enamel paint of white colour with filling cavities with filler complete and marking MES number with synthetic enamel paint of black colour in good and proper size including dismantling of geyser all as directed by Engineer-in-Charge . (NOTE:- Painting work to be carried out after dismantling of geyser)
S&F for copper (CP) hot water pipe for geyser, connection with check nut and washer complete as in repair all as specified and directed.
S&F for recess mounting 2'x2' LED 36 Watt light fittings with LED lamp and required driver, slimmest 9 mm thin in class LED ceiling panel with best in class aesthetic white powder coated frame blended seamlessly with ceiling layout suitable for 600X600mm modular ceiling grid and also can be suspended with provided kit and including connecting up with ceiling rose to fitting and including removing old unserviceable item complete all as specified and directed complete as in repair all as specified and directed, (Make: Crompton Cat No.CCR-127-36-57-SL-NWH / Havells Cat No.PLUTONEO2x2PLR34WLED857S as approved )
M&L for sub main wiring (concealed) complete with 2 run of 6 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 25 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 6 sqmm (green colour) single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty, in and including cutting and cheasing as required size for concealed work complete all as specified and directed after taking down existing sub-main wiring of any type/size from wall and making good disturbed surface. (Note : Two run of 6 sqmm single core copper conductor cable and one run of 6 sqmm single core copper conductor cable as earth continuity and one run of 25mm PVC conduit shall be measured as one unit) (Make : FINOLEX/NICCO/HAVELLS for Copper cable and PRESTOPLAST/FINOLEX/PLAZA/PRECESSION for PVC conduit and conduit accessories as approved)
M&L for sub main wiring (concealed) complete with 2 run of 4 sqmm single core copper conductor (ISI marked) cable 1100 volts grade, FR-LSH type, PVC insulated, unsheathed, flexible, multi stranded colour coded cables drawn through and including rigid PVC conduit of size 20 mm dia medium grade (MMS) with all connected accessories such as Bend, Tee, Elbow, Short pieces etc concealed in wall/roofs/floors and including one run of 4 sqmm (green colour) single core copper conductor cable flexible, PVC insulated, unsheathed, multistranded, 1100 volts grade, FR-LSH type as earth continuity conductor connected to common earth dolly and including making good the disturbed surfaces to match with existing surface and colour coat and applying putty, in and including cutting and cheasing as required size for concealed work complete all as specified and directed after taking down existing sub-main wiring of any type/size from wall and making good disturbed surface. (Note : Two run of 4 sqmm single core copper conductor cable and one run of 4 sqmm single core copper conductor cable as earth continuity and one run of 20 mm PVC conduit shall be measured as one unit) (Make : FINOLEX/NICCO/HAVELLS for Copper cable and PRESTOPLAST/FINOLEX/PLAZA/PRECESSION for PVC conduit and conduit accessories as approved)
BANERJEE ENTERPRISE
M/S H.P Singha
MAZUMDER AND CO
S..S. ELECTRIC CO.
N S CONSTRUCTION
NANDY ENTERPRISE
M/S RAJESH TRADING CO
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .