Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹4.2 LAccepted-AOC | ₹4.2 L | 1 | Accepted-AOC L1 |
| 2 | Rejected-Technical N A | - | - | Rejected-Technical L2 |
| Sl No | Description | Qty | Unit | Basheer P C L2 | T KUNHIRAMAN L1 |
|---|---|---|---|---|---|
| 1.00WARD 2 THANAKKOTTOR ANGANVADI NO 69 | |||||
| 1.00 | 50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 1,507.44 | kg | 183.31 ₹2.8 L | 174.58 ₹2.6 L |
| 1.00 | OD385708/2025-2026:Providing and fixing precoated galvanised iron profile sheets(siz shape pitch of corrugation as approved by Engineer in charge 0.35mm(+0.05%) total coated thicknesswith Zinc coating 120gmsper sqm as per IS-277 in 240mpa steel grade 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns Sheet Sheet should have ave protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12m or as desired by Engineer in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55mm) with EPDM seat, complete upto any pitch in horizontal/verticalor curved surface, excluding the cost of purlins, rafters, and trusses and including cutting to size and shape wherever required. | 167.28 | sqm | 493.58 ₹82,568.53 | 470.08 ₹78,637.33 |
| 1.00 | OD392115/2025-2026:Providing and fixing 150mm wide, square cut PVC 4kgf/cm2 rain water gutter pipe with iron
brackets with 25x5 mm size flat, screws and washers etc., including making necessary
connections with rain water pipes etc. complete. | 20.3 | metre | 442.35 ₹8,979.71 | 421.29 ₹8,552.19 |
| 1.00 | 50.12.2.1:Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required. | 37.5 | sqm | 847.8 ₹31,792.50 | 807.43 ₹30,278.63 |
| 2.00WARD 7 CHEKKIAD ANGANWADI NO 78 | |||||
| 2.00 | OD392074/2025-2026:Labour charge for resizing and fixxing wooden door shutter including all charges etc.. complete work | 1 | Day | 1,231.52 ₹1,231.52 | 1,172.88 ₹1,172.88 |
| 2.00 | 15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below | 1 | each | 371.96 ₹371.96 | 354.25 ₹354.25 |
| 2.00 | 14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand) | 2.29 | sqm | 568.14 ₹1,301.04 | 541.09 ₹1,239.10 |
| 2.00 | 10.25.2:Item Shifted to Sub head 14 as item 14.73
Item Shifted to head 14 as item 14.74
Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works | 19.08 | kg | 174.86 ₹3,337.03 | 166.53 ₹3,178.06 |
Tender Value
₹4.2 L
EMD Value
₹10,590
Closing Date
12 Feb 2026, 10:00 amClosed
SHEELA P R
ASSISTANT ENGINEER LID EW SECTION CHEKKIAD GP
Annual Plan CHEKKIAD GP 2025 2026 P 132 INFRASTRUCTURE DEVELOPMENT IN ANGANVADIS General Civil Work
2026_LSGD_831864_3
006/2025-26/AE/LIDEW/CKD
Open Tender
Civil Works - Roads
180 days
CHEKKIAD GRAMA PANCHAYATH
Please refer Tender documents.
7 documents required · 7 mandatory
₹935
Yes
₹10,590
Yes
10 Mar 2026
4 Feb 2026
13 Feb 2026
4 Feb 2026
12 Feb 2026
4 Feb 2026
WARD 2 THANAKKOTTOR ANGANVADI NO 69
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD385708/2025-2026:Providing and fixing precoated galvanised iron profile sheets(siz shape pitch of corrugation as approved by Engineer in charge 0.35mm(+0.05%) total coated thicknesswith Zinc coating 120gmsper sqm as per IS-277 in 240mpa steel grade 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns Sheet Sheet should have ave protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12m or as desired by Engineer in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55mm) with EPDM seat, complete upto any pitch in horizontal/verticalor curved surface, excluding the cost of purlins, rafters, and trusses and including cutting to size and shape wherever required.
OD392115/2025-2026:Providing and fixing 150mm wide, square cut PVC 4kgf/cm2 rain water gutter pipe with iron brackets with 25x5 mm size flat, screws and washers etc., including making necessary connections with rain water pipes etc. complete.
50.12.2.1:Providing & fixing Poly carbonate corrugated sheet 0.8 mm thick as approved by the Engineer in charge and should be supplied in a single length of 12 M or as decide by the Engineer in charge. The sheets shall be fixed using self drilling / self tapping screw of size (5.5x55 mm) with EPDM seal complete upto any pitch in horizontal/ vertical/ curved surface, but excluding the cost of purlins, rafters, trusses, and including cutting to size shapes where ever required.
WARD 7 CHEKKIAD ANGANWADI NO 78
OD392074/2025-2026:Labour charge for resizing and fixxing wooden door shutter including all charges etc.. complete work
15.12.1:Dismantling doors, windows and clerestory windows (steel or wood ) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead:Of area 3 sq. metres and below
14.1.1:Repairs to plaster of thickness 12 mm to 20 mm in patches of area 2.5 sq meters and under, including cutting the patch in proper shape, raking out joints and preparing and plastering the surface of the walls complete, including disposal of rubbish to the dumping ground within 50 meters lead:With cement mortar 1:4 ( 1 cement : fine sand)
10.25.2:Item Shifted to Sub head 14 as item 14.73 Item Shifted to head 14 as item 14.74 Steel work welded in built up sections/framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required.In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD392125/2025-2026:Providing and fixing precoated galvanised iron profile sheets(siz shape pitch of corrugation as approved by Engineer in charge 0.35mm(+0.05%) total coated thicknesswith Zinc coating 120gmsper sqm as per IS-277 in 240mpa steel grade 5-7 microns epoxy primer on both sides of the sheet and polyster top coat 15-18 microns Sheet Sheet should have ave protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12m or as desired by Engineer in charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55mm) with EPDM seat, complete upto any pitch in horizontal/verticalor curved surface, excluding the cost of purlins, rafters, and trusses and including cutting to size and shape wherever required.
OD392123/2025-2026:Providing and fixing 150mm wide, square cut PVC 4kgf/cm2 rain water gutter pipe with iron brackets with 25x5 mm size flat, screws and washers etc., including making necessary connections with rain water pipes etc. complete.
9.5.1.2:Providing and fixing panelled or panelled and glazed shutters for shutters for doors, windows and clerestory windows, including ISI marked M.S. pressed butt hinges bright finished of required size with necessery screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer - in-charge. Second class teak wood30 mm thick shutters
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1401486.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.05 MB
Tendernotice_2.pdf
PDF • 0.44 MB
Tendernotice_3.pdf
PDF • 0.25 MB
Tendernotice_4.pdf
PDF • 0.29 MB
affidavit.pdf
Tender Documents • 0.24 MB
preliminary.pdf
Tender Documents • 0.26 MB
BOQ_1401486.xls
BOQ • 0.31 MB
viewsbd.pdf
Tender Documents • 1.72 MB
fot.pdf
Tender Documents • 0.25 MB
Download all tender documents and submit your bid