Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹11.6 LAccepted-AOC | 1 | Accepted-AOC L1 accepted | |
| 2 | 2₹12.5 L+₹49,192 (4.11%)Rejected-AOC | 2 | Rejected-AOC L2 rejected |
Tender Value
₹11.3 L
EMD Value
₹28,200
Closing Date
18 Dec 2019, 5:00 pmClosed
Executive Engineer
Office of the Executive Engineer PWD Electrical Division Thiruvananthapuram
Urgent Special repairs, painting and providing mosquito net in ward No. 17 and 18 attached to SAT Hospital, Medical College, Thiruvananthapuram - Installation of the Air conditioner Units.
2019_PWD_328149_1
EDTET/230/2019.
Open Tender
Electrical Works
Item Rate
20 days
Thiruvananthapuram
Please refer Tender documents.
7 documents required · 7 mandatory
₹2,500
Executive Engineer
₹28,200
20 May 2020
9 Dec 2019
23 Dec 2019
9 Dec 2019
18 Dec 2019
9 Dec 2019
9 Dec 2019 - 18 Dec 2019
Amount
SITC of Air Conditioner unit
od135012/2019_2020 : Supply installation testing and commissioning of the following capacity single phase 3 star rating wall mounting type split air conditioner unit fitted with hermetically sealed compressor, operation on refrigerant R32/Non CFC Suitable for wall/floor mounting conforming to IS 1391 (part II) (amendments - I except Power consumption norms) suitable for operation on 230 V, 50 HZ Single phase AC Supply of performing.:- a. Coolingb. Dehumuidifying.c. Air Circulating.d. Filtering.e. Higher Energy Efficient.:-2.0TR single phase split AC unit including copper pipe connection, electric cabling from out door to indoor unit upto 3 meter complete. ( Blue star/ Voltas/ Equivalent)
od135014/2019_2020 : Supply installation testing and commissioning of the following capacity single phase 3 star rating wall mounting type split air conditioner unit fitted with hermetically sealed compressor, operation on refrigerant R32/Non CFC Suitable for wall/floor mounting conforming to IS 1391 (part II) (amendments - I except Power consumption norms) suitable for operation on 230 V, 50 HZ Single phase AC Supply of performing.:- a. Coolingb. Dehumuidifying.c. Air Circulating.d. Filtering.e. Higher Energy Efficient.:-1.5TR single phase split AC unit including copper pipe connection, electric cabling from out door to indoor unit upto 3 meter complete. ( Blue star/ Voltas/ Equivalent)
od135497/2019_2020 : Supply installation testing and commissioning of the following capacity three phase wall mounting type split air conditioner unit fitted with hermitically sealed compressor, operation on refrugerant R32/Non CFC Suitable for wall/floor mounting conforming to IS 1391 (part II) (amendments - I except Power consumption norms) suitable for operation on 415 V, 50 HZ Three phase AC Supply of performing.:-a. Cooling:-b. Dehumidifying.:-c. Air Circulating.:-d. Filtering.:-e. Higher Energy Efficient.f) Copper Condensing coil g) white / off-white :-3 TR Mega Split AC Unit.(Blue star/ Hitachi / Equivalent.)
od135435/2019_2020 : Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 3/8 inch (9.52 mm) and 5/8 inch (15.8 mm) 22 gauge
od135437/2019_2020 : Supply and fixing 25mm PVC drain pipe in position etc as required.
od135439/2019_2020 : Supply, Conveyance and installation of heavy duty stand (one pair) for fixing outdoor unit up to 3 phase AC Unit
od135016/2019_2020 : Supply and providing the following size soft drawn copper pipe for extending the pipe between out door and indoor unit, including insulating the pipe using rubberized foam sleeve 10mm thick, brazing, leak testing etc.:- 1/4 inch (6.35 mm) and 1/2 inch (12.7 mm) 22 gauge
od135441/2019_2020 : Supply, Conveyance, Installation, Testing of 4 KVA/5 KVA voltage stablizer working with input supply (170-230)and output supply of 210-230V.
od142606/2019_2020 : Dismantling the existing single phase 1TR/1.5TR/2TR A/C units, re-install the same in to another location without any damage and make the unit in perfect working condition.
od145034/2019_2020 : Dismantiling the existing 1.5/2TR Air Conditioner unit , attending Minor repairs and re installing to the another position including electric connection, leak testing etc. as required to good working condition.
od145036/2019_2020 : Charges for filling sufficient quantity of freon 22/410A gas for existing air conditoner unit including leak testing rectifying the defects leak arresting including brezing and make the compressor in good working condition for the following. 1TR/1.5TR/2TR/3TR
90.6.5.12 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.19 : Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 2.50 sq mm
S.UnnikrishnanNair
Bidder Name
PIONEER COOLTECH
S.UnnikrishnanNair
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_455503.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .