Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.4 LAccepted-AOC 3082 SECTOR 20D CHANDIGARH 160 020 | CHANDIGARH | CHANDIGARH | 160020 | L1 | Accepted-AOC Being Lowest | |
| 2 | L2₹41.0 L+₹1.1 L (2.85%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | L2 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | L3₹47.9 L+₹8.0 L (20.0%)Rejected-Finance 901 GH 83 SECTOR 20 PANCHKULA 134116 | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | L3₹47.9 L+₹8.0 L (20.0%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L3 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | L4₹48.7 L+₹8.8 L (22.1%)Rejected-Finance 17 PRAKOSHILA CHANDAUTI | CHANDAUTI | CHANDAULI | UTTAR PRADESH | L4 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
21 Sept 2022, 6:00 pmClosed
GE Chandigarh
GE Chandigarh N AREA PIN-160003
REPAIR AND MAINTENANCE OF LT PANEL INDOOR, OUTDOOR, APFC PANEL, INCLUDING REPAIR/REPLACEMENT OF UNSV E/M FITTINGS AND FIXTURES AND EXISTING UNSV CFL/TUBE LIGHT FITTING WITH INVERTER TYPE LED FITTING AT N AREA AND HALLOMAJRA UNDER GE CHANDIGARH.
2022_MES_547808_1
GE/CHD-41/2022-23
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
Chandigarh
Class D category b(i) for contractor enlisted in MES
6 documents required · 6 mandatory
₹500
GE Chandigarh
₹90,000
Yes
21 Nov 2022
26 Aug 2022
23 Sept 2022
26 Aug 2022
21 Sept 2022
9 Sept 2022
26 Aug 2022 - 4 Sept 2022
Amount
Dismantling of old unserviceable ACSR conductor and supply and fixing by stratching required tension new ACSR (Aluminium Conductor Steel Reinforced) on existing LT pole conductor complete.
M&L galvanised steel wire 4 mm dia for making craddle, hexagonal / rectangular, across span complete and including dismantling of old unserviceable GI wire.
Excavation in trenches in any type of soil not exceeding 1.50 metre wide and not exceeding 1.50 metre in depth; for laying of cable,poles stay etc. and getting out complete all as specified.
Excavation in trenchs exc. 1.5 mtr in depth but not exceeding 3 mtr in depth and getting out in any type of soil complete all as specified.
Excavation in trenches exc. 3.0 mtr in depth but not exceeding 4.5 mtr in depth and getting out in any type of soil complete all as specified.
Returning filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick each complete all as specified.
Removing excavated spoil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified.
Sand cushioning with clean dry sand to cables with layer of sand 8cm before laying of cable and 15cm thick after laying of cable complete all as specified. Note : For payment purpose punned thickness of 18cm shall be measured against spread thickness of 23cm as mentioned in para 19.75 of SSR part-I
Supply and laying of class B bricks for under ground cable protection as directed by Engineer- in - charge
Cement concrete 1:4:8 type D-2 using 40 mm graded crushed stone aggregate in foundation filling & mass concrete for poles/struts/stays assembly including provision of necessary form work finishing the exposed surface even and smooth in cement mortar 1:3 complete all as specified.
Cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate in coping padestal to poles and repair to road cutting including necessary finishing the exposed surface even and smooth in cement mortar 1:3 complete all as specified.
Supply, and fabrication in repair LT cubical panel board indoor type factory fabricated totally enclosed dust and vermin proof free standing fully compartmentalized and design suitale for 415 volts, 3 phase 50 HZ 4 wire AC system degree of protection shall be IP-54 and made out of 2.00 mm thick CRCA sheet and suitable to accommodate Incomer : MCCB 630 Amps -1 No Front operatd changeover switch 400 Amps - 02 Nos , Out going : MCCB 150 to 200 amps -08 Nos, MCB TPN 63 Amp - 02 Nos The panel shall have TPN copper bus bar made of high conductivity pure copper of rating 1000 Amps and provision of interconnection with copper strip of different size from main bus bar to switchgear . The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulators of size not less than 50x50 mm conical/square type at a maximum interval of 300 mm through out the length of the TPN bus bar and provided with CTs of appropriate rating for metering equipments. The cubical shall have copper TPN extension links of current carrying capacity 300 Amp ,and 150 Amps respectively . The extension links shall not be less than 300mm long supported on DMC/epoxy insulators having provision for termination of incomer and out going cables. The panel shall be powder coated seimen grey structural and mounted on mounted on a zinc metal coated stand of size ISMC 100 x 50. Panel shall be front and back openable, double door system lockable/openable by key from both sides and shall have louvers and air vent gasket for natural flow of air 'U' type gasket shall be used to make the panel completely vermin proof. The bottom of the panel shall contain a detachable plate having provision of entry of amroured cable of adequate size with MS glands
Supply, and fabrication in repair LT cubical panel board outdoor type factory fabricated totally enclosed dust and vermin proof free standing fully compartmentalized and of suitable size design suitale for 415 volts, 3 phase 50 HZ 4 wire AC system degree of protection shall be IP-54 and made out of 2.00 mm thick CRCA sheet and suitable to accommodate incomer :- MCCB 200 Amps -1 No bus bar chamber for TPN bus bar , Volt meter, ammeter, 03 nos indicator lamps, and Out going :-MCCB 63 to 100 amps -04 Nos, MCB TPN, 63 Amps - 02 Nos, The panel shall have TPN copper bus bar made of high conductivity pure copper of rating 400 Amps and provision of interconnection with copper strip of different size from main bus bar to switchgear . The TPN bus bar shall be insulated with colour coded heat shrinkable sleeve and shall be mounted on DMC/epoxy insulators of size not less than 50x50 mm conical/square type at a maximum interval of 300 mm through out the length of the TPN bus bar and provided with CTs of appropriate rating for metering equipments. The cubical shall have copper TPN extension links of current carrying capacity 300 Amp ,and 150 Amps respectively . The extension links shall not be less than 300mm long supported on DMC/epoxy insulators having provision for termination of incomer and out going cables. The panel shall be powder coated seimen grey structural and mounted on mounted on a zinc metal coated stand of size ISMC 100 x 50. Panel shall be front and back openable, double door system lockable/openable by key from both sides and shall have louvers and air vent gasket for natural flow of air 'U' type gasket shall be used to make the panel completely vermin proof. The bottom of the panel shall contain a detachable plate having provision of entry of amroured cable of adequate size with MS glands
Supply, install & connecting up Air circuit braker manual draw out type 3 pole rating 800 Amp, breaking capacity 50 KA with intelligent micro processor release 4.1 features with LCD display, current mesurement , thermal memory, fault indication and LSING protection etc. including carefully taking down old unservicable ACB all as specified and directed by in Engr in charge.
Supply and fix MCCB 4 Pole, 415 V, adjustable thermal type (40% to 100%) and adjustale magenetic release TPN 415 volt, bracking capacity 50 KA, ICS =100 ICU, Adjustable type, 630 Amps complete all as specified and directed by in Engr in charge.
Supply and fix MCCB 4 Pole, 415 V, adjustable thermal type (40% to 100%) and adjustale magenetic release TPN 415 volt, bracking capacity 35 KA, ICS =100 ICU, 400 Amps complete all as specified and directed by in Engr in charge.
Supply and fix MCCB 4 Pole, 415 V, Adjustable thermal type (40% to 100%) type, adjustale magenetic release TPN 415 volt 250 Amps with breaking capacity 36 KA with ICU=ICS 100% complete all as specified and directed by in Engr in charge.
Supply and fix MCCB 4 Pole, 415 V, adjustable thermal (40% to 100%) and adjustale magenetic release TPN 415 volt, bracking capacity 35 KA, ICS =100 ICU, 200Amps complete all as specified and directed by in Engr in charge.
Supply and fix MCCB 4 Pole, 415 V, fixed type, 160 Amps with breaking capacity 25 KA with ICU=ICS 100% complete all as specified and directed by in Engr in charge.
Supply and fix MCCB 3 Pole, 415 V, adjustable thermal (40% to 100%) and adjustale magenetic release TPN 415 volt, bracking capacity 35 KA, ICS =100 ICU fixed type, 100 Amps with breaking capacity 25 KA with ICU=ICS 100% complete all as specified and directed by in Engr in charge.
Supply and fix MCCB 3 Pole, 415 V, adjustable thermal (40% to 100%) and adjustale magenetic release TPN 415 volt, bracking capacity 35 KA, ICS =100 ICU fixed type, 63 Amps with breaking capacity 16 KA with ICU=ICS 100% complete all as specified and directed by in Engr in charge.
Disconnecting, dismantling, taking out & removing unserviceable volt meter and Supplying, fixing, testing and commissioning of digital electronic volt meter 0-500 V range suitable for LT 415 Volts panel flush pattern square type 96mmX96mm with adopter complete with button all as specified and directed. Note :- The rate quoted shall be deemed to including the following:- (i) Control wiring for auxiliary supply 230 Volts AC if required. (ii) Cutting the sheet of the panel to suit with existing panel if required. (iii) Calibration and testing the meter.
Taking down old unserviceable LT current transformer and supplying, fixing, testing and commissioning of resin cast tap wound LT current transformer for rating 100/5A to 200/5A on LT panel board and connections secondary terminals to ammeter. Make : Rishab/GE/Kappa/AE
Supply and fix in repair Indicating lamps 22.5 mm dia LED type, 230 V AC to show three phase availability complete all as specified and directed by in Engr in charge.
Supply and fixing of Change over switch 100 Amps, TPN, 420 volts front operated type complete all as specified and directed by in Engr in charge.
Supply and fixing of Change over switch 160 Amps, TPN, 420volts front operated type complete all as specified and directed by in Engr in charge.
Supply and fixing of Change over switch 400 Amps, TPN, 420 volts front operated type complete all as specified and directed by in Engr in charge.
Supply and fix in repair MD—XL Double metalized paper (Extra Low Loss) Capacitor for 3 phase 440 V & 50 Hz, system for permissible non- leaner load 20% of capacity 5 KVAR complete all as specified and directed by in Engr in charge.
All as per item No 30 here in beore but of cap 7.5 KVAr
All as per item No 30 here in beore but of cap 12.5 KVAr
All as per item No 30 here in beore but of cap 15 KVAr
All as per item No 30 here in beore but of cap 20 KVAr
All as per item No 30 here in beore but of cap 25 KVAr
Supply and fix in repair 3 phase 415 volts 50 HZ capacitors duty electromagnetic switiching on and off operation system in the form of power contractor with NO and 1 NC contacts of cap upto 12 amps complete all as specified and directed by in Engr in charge. Make Legrand /BCH/Siemens
All as per item ser No 36 here in before but contactor of cap up 16/18 Amp 3 Pole AC 3 Capacitor Duty
All as per item ser No 36 here in before but contactor of cap up 32 Amp 3 Pole AC 3 Capacitor Duty
All as per item ser No 36 here in before but contactor of cap up 50 Amp 3 Pole AC 3 Capacitor Duty
All as per item ser No 36 here in before but contactor of cap up 63 Amp 3 Pole AC 3 Capacitor Duty
Supply and fix MCB 10 Amp TP C Curve complete all as specified and directed by in Engr in charge.
Supply and fix MCB 16 Amp TP C Curve complete all as specified and directed by in Engr in charge.
Supply and fix MCB 25 Amp TP C Curve complete all as specified and directed by in Engr in charge.
Supply and fix MCB 50 Amp TP C Curve complete all as specified and directed by in Engr in charge.
Supply and fix MCB 63 Amp TP C Curve complete all as specified and directed by in Engr in charge.
Supply and fix ON,OFF Indicating Lamp Make: BCH /Siemens / Legrand /L&T
Supply and fix Start, Stop Push Button for APFC Panel Make: BCH /Siemens / Legrand /L&T
Supply and fix in repair 3 phase sensing micro processor based sensing repay for controlling power factor NRC 12 , 6 steps LCD display duel power factor setting 110V-415V , 1A/5 A, Harmonic spectrum conforming to cat part No 52450 of Schneider, Legrand or equivalent as approved by GE.
S&F in repair MCB, 5-32 Amp, 240 volt, single pole, breaking capacity not less than 10 kA, B curve complete all as specified.
S&F in repair MCB, 32/40 Amp, 240 volt, single pole & neutral, breaking capacity not less than 10 kA, B Curve complete all as specified.
S&F in repair MCB, 40-63 Amp, 415 volt, triple pole & neutral, breaking capacity not less than 10 kA, B Curve complete all as specified.
Taking out existing damage/unservisable PVC\ XLPE insulated, armoured, aluminium conductor 1100V grade cable of any size and core from trenches, pipes, walls and/or poles, complete all as specified . NOTE: Excavation and earthwork shall be measured and paid for separaetly
Supply & Laying of PVC insulated,armoured heavy duty, electric cable with stranded aluminum conductor of size 3.5 core 240 sqmm 1100 volts grade, laying in trenches, passing through pipes, fixed along walls and/or poles complete all as specified complete all as specified and directed by in Engr in charge.
All as per item No 54 above but cable of size 185 Sq.mm, 3.5 core
All as per item No 54 above but cable of size 150 Sq.mm, 3.5 core
All as per item No 54 above but cable of size 120 Sq.mm, 3.5 core
All as per item No 54 above but cable of size 70 Sq.mm 3.5 core
All as per item No 54 above but cable of size 50 Sq.mm, 3.5 core
All as per item No 54 above but cable of size 35 Sq.mm, 3.5 core
All as per item No 54 above but cable of size 25 Sq.mm, 3.5 core
All as per item No 54 above but cable of size 10 Sq.mm, 2 core
All as per item No 54 above but cable of size16 Sq.mm, 4 core
S & F in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size 70 Sqmm to 150 Sqmm, 3.5 core complete all as specified. Make : DENSON, M-SEAL, BIRLA-3M.
S & F in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size185 Sqmm to 300 Sqmm, 3.5 core complete all as specified.Make : DENSON, M-SEAL, BIRLA-3M.
S & F in repair heat shrinkable straight through joint for 1100 volt grade XLPE cable of size 25 Sqmm to 50 Sqmm, 3.5 core complete all as specified.Make : DENSON, M-SEAL, BIRLA-3M.
Cutting road for passing the cable/pipe and making good with plain cement concrete 1:3:6, type C-1 using 20 mm graded crushed stone aggregates complete all as specified. Note :- 1.Average width of excavation 300mm,average depth 600mm and average thickness of PCC 450mmm, 2. PCC 1:3:6 Type C-1 shall be measured and paid separately
S & F in repair 100 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified.
S & F in repair 80 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified.
S & F in repair 50 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified.
S & F in repair 40 mm bore Tubes ‘light grade’, galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified .
Repair to LT panel board/Feeder pillar box indoor/outdoor type by means of cutting of damaged portion of top/ bottom sheet, front /back door sheet . Welding new peace of CRCA sheet 2 mm thick as required at site . Replacement of unsv door hinges and door lockes with keys. Scrubing /scratching of old rusted paint by burning through blow lamps and applying metalic filler . Painting of LT Panel board/Feeder pillar box any size any description , externally and internally with 02 coats of approved colour of paint with two coats of superior quality synthetic enamel paint over a coat of red oxide as primer complete al as specifired and as directed all as as directed by Engr-in-Charge.
Taking down old unserviceable bus bar chamber any from position and Supply & Fix bus bar chamber havng IP -42 protection as per IS spections,fabicated out of CRCA sheet 2.0 mm thick ,not less then 14 gauge sheet of size 750x 400 x 200 mm ,with provision of TPN, 415 Volt with 200 Amp rated coppper bus bar of size not less then 25x3 mm thick And 300 mm long , mounted on PVC/ Epoxy insulator,factory made sheet metal enclosure for distribution board ,including provn with backalite sheet of size 600x300x 3 mm thick ,The DB shell be front door type with 2 Nos locking arrangement, semi glossy finish with powder coated sprayed paint and baked at high temprature, incl making necessary connection with 25x3 MM thick copper Strip from MCCB to bus bar, incl making nitch in walls and making good the surface complete all as specified and comprises of following :- (a) MCBs SPN 32 Amp mounted on Din rail channel =10 Nos (b) MCCB ,100 AMP,4Pole,25 KA 415 Volts 63%-100% ADJUSTABLE, 50 HZ -1No Make :L&T/LEGRAND/ BCH. Note:- MCCB shall be fixed on adjustable mounting so as to accomodate operating knob projected out side the front door
Taking out old unsv eathing earthing material incl demolition of PCC chamber and RCC cover
Supply , and laying in repair GI earth plat of size 60cmx60cmx6 mm thick (having drilled two nos holes of dia 10 mm one at centre and other in between top and centre for fixing of GI strip/ GI wire any size ) laid vertically in centre of a earth pit of depth 4.5 Mtrs complete al as specified and as directed.
Supply and fixing in repair GI Strip of size 32x6 mm with GI earth plate under item ser No 75 above complete all as specified and as directed
Supply and fixing in repair GI Strip of size 25x4 mm with GI earth plate under item ser No 75 above complete all as specified and as directed
Supply and fixing in repair GI wire of size 4 mm with GI earth plate under item ser No 75 above complete all as specified and as directed
Supply and fixing GI bolt( full thread) ,Nut and wahsers of size 10 mm thick 25 mm long Note :( One GI bolt,one nut and two nos washers shall be considered as one set)
Supply and fixing in repair GI pipe medium grade of size 15 mm complete all as specified and as directed
Supply and fixing in repair GI watering funnel with wire mesh complete all as specified and as directed
Supply and filling sea salt in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge
Supply and filling charcoal dust in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge
Supply and filling bentonite powder in earth pit complete all as specified in SSR part -I and as directed by Engr-in-Charge
M&L PCC 1:3:6 Type C-1 using 20 mm graded black trap/granite/baslt stone including necesary form work for repair of earth pit complete all as specified in SSR part I and as directed by Engr-in-charge
Precast RCC type B-1 (1: 1 ½ : 3), using 20 mm graded stone aggregates landings, cover slabs (for manholes etc.) /earthing and similar articles with plain faces including all mouldings but excluding frame, set in cement mortar 1:4 including form work and demolation of old unsv cover complete all as specified Note :- Reinfrocement shall be measured & paid separetly.
MS TMT bars 6 to 8 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with mild steel wire (annealed ) not less than 0.9 mm dia all as directed and specified.
Supply and fixing GI protection pipe light grade of size 25 mm complete all as specified and directed by in Engr in charge.
Supply and fixing GI protection pipe light grade of size 15 mm complete all as specified and directed by in Engr in charge.
Supply and fix in repair Astronomical time switches with USB Key, two Chanels single phase with sheet metal enclosure box of capacity 16 Amp,incl two pole contactor nominal rating 16 Amp 2NO,2NC complete - 1No complete all as specified . MAKE : Hager/ Cat No EE181 /LegrandMaxiRex4QTB. Cat No: 649914&004128 or equivalent in L&T /Bosch
Supply fixing and commissioning in repairs Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 20 KVAR wih MCCB as incomer complete all as specified. Make : L&T/BCH/Seimens/scheneider/Legrand
Taking down existing unsv sign board any type and material and labour for Informatory sign board of size 1000mm x600mm made out of 2mm thick Stainless steel sheet fixed on Stainless steel sheet frame of ractangular shape 45mmx25mm fixed on stainless steel pipe 50mm dia 2.25mtr long vertical member-2nos ,including letter writing (100 to 150 words) , logo/drawing/schematic diagram made with computerized printing of fully retro reflective with high intensity prismatic tape pasted on sheet with single side writing including vertical pipe emmebedded in 0.30x0.45mtr in PCC (1:3:6 ) type C-1 complete all as specified and directed by the Engineer-in-charge Note : (i)The cost of Excavation post hole, earth work , PCC for foundation etc shall be deemed to be included in the unit rate of this item. Nothing extra shall be admissible on this account.(ii) The letter size of Main heading shall be minimum100mmx10mm and sub heading letter size shall be minimum 50mmx5mm.(iii) The drawing and colour of writing work shall be got approoved by Engineer in charge.
Taking down the existing deteriorated wooden sign board any type and repalcing with new sign board of size 1000mm x 600mm with 2mm thick stainless steel sheet fixed on stainless steel sheet frame of ractangular shape 45mmx25mm, computerised retroprinting lettter writing /drawing/schematic diagram with retro reflective with high intensity prismatic tape on one side with suitable adhesive ,fixed on wall with suitable hanging arrangement all as directed by Engr-in-Charge. Note-The drawing and colour of writing work shall be got approved by Engineer in charge.
Supply & install in repairs steel tubular pole swaged welded with MS base plate size 30cm x 30cm x 6mm thick final taper plug bolts nuts & washers as per IS: 2713 (part-I) 1980 made out of MS tubing including painting of two coats of aluminium paint of approved quality over one coat of red oxide primer length 9.00 mtr long 410 SP -31 using for any description of external electric work incl desmentling of old unsv RCC pole all as specified and directed by Engr-in-charge.
Cutting & trimming of tree trunks / branches of grith not more than 80 mm falling on or likely to fall on LT over head electrical lines for a clearence of 6 meter on ground from the nearest counductor / pole /earth etc. & desposal of unservicable materials to distance not exc.50 mtrs. & clearing of site all as directed by Engg. -In - Charge. Note : Pole to pole span length approx 30 mtrs each
Preparation of surfaces of LT RCC/PCC poles and applying two coats of cement base white paint (1st quality) and writing pole No, and Luminious paint Strip upto 1.5 mtr height at an intervals of 30cm each yellow and black strip from the ground level and above coping for 09 mtr LT pole complete all as directed.
Preparation of surfaces of LT Steel poles by and painting applying one coats of aluminium paint and writing pole No in black and yellow. Strip upto 1.5 mtr height at an intervals of 30cm each from the ground level and above coping for 09.00 mtr pole all as directed at site.
M&L for stay assembly for LT poles comprising of 20mm dia, 2.15 mtr long galvanized stay rod , having 7 / 2.25 mm GI stay wire stranded and 300mm X 500mm X 6mm thick MS stay plate, complete all as shown on electrical plate No 1 of SSR, Part-I with and including all necessary fittings/accessories like loop type insulator overall dimensions 90mmx140mm, clearance of hole 25.5mm, shackle & stay clamps made out of 50x6mm MS flat iron, necessary excavation and earth work in soft/loose soil and PCC works in (1:3:6) type C-2 (using 40mm graded stone aggregate) including taking out and dismantling old unserviceable stay assembly complete all as specified and directed by Engineer-in-Charge.
Cleaning the area of electric supply, supply installations by cutting and removing jungle sturts, roots, bushes plants small trees from roots etc incl levelling of area and deposited to n.exc 50 mtr to 100 mtr out side installations as directed by Engr-in-Charge.
M&L for danger notice board / plate of 1.6mm thick M.S sheet vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour 440 Volt and fixed with M.S clamps, bolts and nuts of approved size, for LT, 20 x 15cm size including removing old unserviceable as specified.
Material and labour for spreading and levelling crushed stone aggregate 63 mm 150 mm average thickness around transformer , two pole/four pole structure and panel board including removing of grass and bushes from roots of the area.
Supply & Laying of PVC insulated,armoured heavy duty, electric cable with stranded aluminum conductor of size 3.5 core 400 sqmm 1100 volts grade, laying in trenches, passing through pipes, fixed along walls and/or poles complete all as specified.
All as per item ser No 102 above but cable of size 500 sqmm
Testing of Earth resistance with an earth megger after disconnecting the same from the equipment in presence of MES rep for for all electrical equipments and writing earth resistance result on the earth cover with black or paint and in a separate earth test register including connecting the same afte testing complete all as directed
M&Lin repair for Mild steel work of angle iron section or any section as in posts & struts for cattle/security fencing/ including cutting top to shape, drilling holes, notching for wires etc, flat iron fillets (for securing wire mesh etc) including 12 mm dia round running bar as in fencing post, including all necessary drilling, bolting or riveting etc and similar work conforming to Fe-410-w( GraeE-250quality –A) complete all as specified and as directed by Engineer –in- charge
M&L in repair for Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240omplete all as specified and as directed by Engineer –in- charge
S & F in repair Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm of an colour having tensile strength of 550Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and as directed.
Disconnecting defective voltage stabilizer indoor type servo controlled , oil cooled 3 phase of capacity 50 KVA to upto and including 125 KVA draining out complete stabilizer oil & storing the same in suitable containers ( to be arranged by contractor ) opening the top cover and disconecting unsv servo motors , lifiting up core assembly carefully to check the condition of widing and core . Retanking the same after repair refilling the transformer oil after dehydration and filteration (dehydration and filteration to be paid separately) including checking of leakage of transformer body and welding works required for making transformer body leak proof transportation of transformer to and from site to work shop and re-installation the same at any site complete all as specified and directed.
M&L for replacement of burnt /defective stabilizer copper coil with new one made out of super enamelled heavy duty copper wires of size matching to the existing one including varnishing, drying and insulating material in transformer complete all as specified and directed.
S&F in repair single phase AC servo motor(as per sample) suitable for voltage stabilizer of cap 125 KVA
S&F in repair IC based solid state relay for voltage stabilizer of cap 125 KVA
S&F fix in repair plug in control card (PCB) for 3 phase servo controlled voltage stabilizer of cap 125 KVA
M&L for replacement of synthetic rubberised cork sheet gasket 1/4" thick suitable for main body top cover of transformer Voltage stabilizer of cap 125 KVA.
M&L for replacement of defective/ cracked porcelain bushing (set of four) of suitable size of voltage stabilizer of cap 125 KVA including washers of good quality complete all as specified and directed.
Supply and fix in repair bush rod made out of copper with brass nuts and washers of required length including and dia (as per existing) connecting up with coil of voltage stabilizer of cap 125 KVA complete all as specified and directed.
Supply and filling voltage stabilizer insulation oil (transformer oil) for topping up the level of oil/ new filling, having dielectric strength 40 KV during filling after initial filteration, conforming to relevent IS-335 (Transformer oil to be supplied in sealed container) complete all as specified and directed.
Taking out old unsv bus bar chamber after disconnecting existing cable connection carefully. Supply and fixing new bus bar chamber TPN of size 0.6x0.6x0.4 mtr with front and back openable and lockable made out of 3 mm thick CRC sheet and supported on MS angle legs of size 40x5mm of 0.4 mtr -04 Nos. and grouted in PCC 1:3:6. The bus bar chamber shall have 04 nos aluminium bus bars of current carrying capacity .400 amps insulated by colour coded heat shrink sleeves and supported on epoxy insulators. The bus bar chamber shall have space for provision of one No 4 Pole MCCB 200 amps to 300 amps. The bottom of the bus bar chamber shall have detachable plate and provision of suitable size MS glands.
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 400 sqmm .
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 240 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 185 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 150 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 120 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 95 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 70 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 50 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 35 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 25 sqmm
Supply and fixing in repair ,heavy duty aluminium lugs for LT UG cable of size 16 sqmm
Supply and fixing in repair ,heavy duty Copper lugs for LT UG cable of size 16 sqmm
Supply and fixing in repair, heavy duty copper lugs for LT UG cable of size 10 sqmm
Supply and fixing in repair,heavy duty copper lugs for LT UG cable of size 6 sqmm
Disconnection and removing the u/s light fitting and S&F Recess - mounting low height round LED 12 Watts , 230Volt energy saving DOWN LIGHTERS designed with excellent thermally managed aluminium pressure die-cast housing with heat dissipating fine for larger surface area, finished in epoxy -coated white with revolntionary flicker controlled technology to reduce harmful invisible flicker present in LED highting sources size Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Recess - mounting low height round LED 15 Watts , 230Volt energy saving DOWN LIGHTERS designed with excellent thermally managed aluminium pressure die-cast housing with heat dissipating fine for larger surface area, finished in epoxy -coated white with revolntionary flicker controlled technology to reduce harmful invisible flicker present in LED highting sources size Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Recess - mounting low height square LED 15 Watts , 230Volt energy saving DOWN LIGHTERS designed in polycarbonate housing with revolutionary flicker controlled trchnology to reduce harmful in visible filicker present in LED lighting sources Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Recess - mounting low height square LED 15 Watts , 230Volt energy saving DOWN LIGHTERS designed in polycarbonate housing with revolutionary flicker controlled technology to reduce harmful invisible filicker present in LED lighting sources Complete all as specified and as directed by Engineer in Charge. MAKE: C&S/Crompton/Havells/Orient.
Disconnection and removing the u/s light fitting and S&F Surface - mounting low height square LED 15 Watts , 230Volt energy saving DOWN LIGHTERS designed in polycarbonate housing with revolutionary flicker controlled technology to reduce harmful invisible filicker present in LED lighting sources Complete all as specified and as directed by Engineer in Charge. MAKE: C&S/Crompton/Havells/Orient.
Disconnection and removing the u/s light fitting and S&F Recess mounting back-lit LED 2x2 (36 watts) tile in CRCA housing with full-opal diffuser suitable for Armstron/Grid ceilings with revolutionary Flicker controlled technology to reduce harmful invisible flicker present in Led lighting sources Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Recess mounting back-litl LED 1x4 (36 watts) tile in CRCA housing with full-opal diffuser suitable for Armstron/Grid ceilings with revolutionary Flicker controlled technology to reduce harmful invisible flicker present in Led lighting sources Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Surface mounting back lit LED 2x2 (36 Watts) tile in CRCA housing with full-opal diffuser for soft & glare free light distribution with revolutionary Flicker controlled technology to reduce harmful invisible flicker present in LED lighting sources Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Recess-mounting low height square LED 6 (watts) downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat-dissipating fins for larger surface area, finished in epoxy powder-coated white.Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Recess-mounting low height square LED 12 (watts) downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat-dissipating fins for larger surface area, finished in epoxy powder-coated white.Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Recess-mounting low height square LED 15 (watts) downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat-dissipating fins for larger surface area, finished in epoxy powder-coated white.Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Ultra slim surface-mounting round LED 12 (watt) downlighter designed with excellent thermally managed aluminium pressure die-cast housing with heat dissipating fins for larger surface are finished in epoxy powder-coated white to deliver high-efficacy light output and uniformity, utillising edge-lit technology.Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&FHighly efficient IP66 LED (40 Watt) street light with aluminium pressure die cast housing, toughened glass in thr front and peanut lens for batwing light distribution, highter spacing between poles and maintenace free system Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&FHighly efficient IP66 LED (45 Watt) street light with aluminium pressure die cast housing, toughened glass in thr front and peanut lens for batwing light distribution, highter spacing between poles and maintenace free system Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&FHighly efficient IP66 LED (60 Watt) street light with aluminium pressure die cast housing, toughened glass in thr front and peanut lens for batwing light distribution, highter spacing between poles and maintenace free system Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Highly efficient IP66 LED (25 watt) streetlight with high-power leds, having aluminium pressure die-cast housing and PC cover in ther front and lens for batwing light distribution Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Highly efficient IP66 LED (36 watt) streetlight with high-power leds, having aluminium pressure die-cast housing and PC cover in ther front and lens for batwing light distribution Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F Highly efficient IP66 LED (45 watt) streetlight with high-power leds, having aluminium pressure die-cast housing and PC cover in ther front and lens for batwing light distribution Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F High efficiency IP66 innovative LED (150 watt) floodlight with pressure die cast aluminium housing and toughened glass in the front with unique flood optics to ensure uniform distribution and savihng upto 50% as compared to conventional system Complete all as specified and as directed by Engineer in Charge.
Disconnection and removing the u/s light fitting and S&F IP65 LED (2 watt) solar surface post top with built in solar panel, LED light and lithium battery with chgarge controller compared to conventional system Complete all as specified and as directed by Engineer in Charge.
M&L for Point wiring complete with 1.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistandad copper conductor, drawn through and including rigid non-metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 1.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly concealed in wall on top for housing the switches, socket outlet etc., for One light point controlled by one, one way 5 Amps switch all as specified and as directed
All as per item no. 152 but One ceiling fan/exhaust fan point controlled by one, one way 5 Amps switch
All as per item no. 152 but One 3 pin socket outlet 5 Amps on independent board
All as per item no. 152 but One 3 pin socket outlet 5 Amps on same board
All as per item no. 152 but One light point controled by two, two way 5 Amps switches.
All as per item no. 152 but One bell/ buzzer point controled by one bell push on same board with other switches or on independent board.
M&L for Point wiring complete with 2.5 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 2.5 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
M&L for Point wiring complete with 4.0 Sqmm single core, PVC insulated unsheathed, FRLS cable, 1100 volts grade, multistranded copper conductor, drawn through and including rigid non metallic PVC conduit and conduit accessories fixed on surface of wall/ceilings or concealed etc., including provision of PVC insulated 4.0 Sqmm FRLS cable with copper conductor for earth continuity and connected to common earth dolly and metal boxes concealed in wall , modular cover plates with frames on top for housing the switches, socket outlet etc., all as specified and as directed for one switch socket outlet 16 Amps on independent board.
M&L for Point wiring with 1.5Sqmm copper conductor FRLS (multistrand) PVC insulated ISI marked unseathed cable PVC insulated ISI marked unseathed FRLS in existing concealed/surface conduit including concealed in wall, modular MS Box, 1.6mm thick with modular cover plate with frame as required at site suitable for modular switch, socket, fan regulator, bell push, two way etc., for One light point controlled by one way 5 Amps switch NOTE : (i) Modular switch socket fan regulator shall be measured and paid separately under respective items. (ii) Cost of mudular MS Box, codular cover plate an frame of any modules as required at site and as directed by engineer-in-charge is deemed to be included in the quoted rates.
All as per item no. 160 but One fan point controlled by one way 5 Amps switch
All as per item no. 160 but One 3 pin socket outlet 5 Amps on independent board
All as per item no. 160 but One 3 pin socket outlet 5 Amps on same board
All as per item no. 160 but One light point controlled by two, two way 5 Amps switches.
All as per item no. 160 but One bell point controlled by one way bell push switches.
Taking down carefully aluminum/copper point wiring (light, fan, socket or power) complete along with fittings such as switches, ceiling roses, bell, regulators sockets etc, and removing from site and making good distribut surfaces of walls, floors etc all as directed.
M&L for Sub main wiring/power wiring complete with two runs of 4.0 Sqmm, single core, PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistranded with copper conductor, drawn through and including suitable size of rigid non metallic PVC conduit pipe and accessories on surface wall/floors/concealed etc. with one run of PVC insulated, 4.0Sqmm FRLS copper conductor for earth continuity all as specified and as directed. NOTE :- Two runs of main copper conductor, one run of copper conductor for earth continuity and one run of conduit shall be measured as one unit length.
All as per item No 167 here in above but with 2X6 Sqmm for phase and neutral and 1x6 Sqmm for earth wire complete.
All as per Item No 167 here in above but of 3X2.5 Sqmm.
Disconnection and removing the u/s 3X1.5 Sqmm PVC insulated unsheathed cable from the existing conduit and M&L for 3x1.5 Sqmm PVC insulated, unsheathed FRLS cable, 1100 Volts grade, multistandard with copper conductor drawn in the existing metal/PVC conduit & Casing capping including connecting of the ends into the switch / socket/ DB complete.
Taking down existing unserviceable sub main wiring 2.5/4/6 Sqmm aluminium cable all as directed.
Supply and fixing switch piano flush type universal single pole one way 5 amps 230 volts. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing switch socket flush type universal 2 in 1, 3 pin, 5 Amps 230 volts. Makes :- Anchor/Cona/Leader/SSK
Supply and fixing switch piano flush type single pole one way 15 Amps, 230 volts. Makes :- Anchor/SSK/Leader/Bajaj
Supply and Fixing switch socket flush type universal 2 in 1, 3/6 pin 15 Amps 230 volts. Makes :- Anchor/Cona/Leader/SSK
Supply and fixing switch piano flush type single pole two way 5 amps 230 volts. Makes :- Anchor/Cona/Leader/Bajaj
Supply and fixing bell push switch flush type universal single pole 5Amp, 230Volt. Makes :- Anchor/Cona/Leader/SSK
Supply and Fixing step type electronic fan regulator of capacity 100 watts 230 volts for ceiling / exhaust fan flush type. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing Ceiling rose 3 terminal 5 Amps 230 volts PVC/Polycarbonate, insulated body. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing Ding Dong AC 230 volts,single pole. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing 5/6 Amps bell push one modular switch complete. Makes :- Anchor/Cona/Leader/Bajaj
Supply & Fixing 5/6 Amps 1 way one modular switch complete. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing 5/6 Amps three pin socket modular complete. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing 15/16 Amps one way one modular switch complete. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing 15/16 Amps three pin socket modular complete. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing 5 Amps 2 way modular switch complete. Makes :- Anchor/Cona/Leader/Bajaj
Supply and Fixing lamp holder, angular type, PVC/ polycarbonate with back plate of capacity 5 Amps 230 volts suitabel for general lighting system complete all as specified and as directed. Make : Anchor//Leader/Bajaj
Disconnection and removing the u/s LED lamp and S&F LED lamp 9 watts complete all as spfd and directed. MAKE : Philips/Halonex/Crompton
Disconnection and removing the u/s casing caping conduit and S&F PVC casing caping of size 20mm including cut to shape and size to match the existing conduits suitable for LT electric supply along with necessary fixing arrangements complete.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 4.5 meter below normal ground level (with top edge of earth plate not less than 3.75 meter below ground level) connected to GI strip 32 x 6mm main earthing lead by means of galvanized bolts, nuts and washers with connected to earth test point & to main switch board /panel etc. all as specified and testing on completion with and including necessary excavation and earth work in any type of soil, earth electrode, earthing lead from electrode to equipment/substation/panel etc, adequate quantity of charcoal dust and common salt, test point terminal block made out of phoshper bronzein sheet steel box, PCC (1:3:6) type C-1 (using 20mm graded black trap/granite/Basalt stone aggregate) for earth pit with 40 x 40 x 6mm mild steel angle iron frame for cover, pre cast RCC (1:2:4) type B-1 (using 20mm graded black trap/granite/Basalt stone aggregate) 40mm thick cover reinforced with 8mm dia TMT bars 3 Nos both way with 12mm dia round bar handle, GI light grade watering pipe 20 mm dia with funnel and wire mesh, and 40 mm dia GI light grade earth lead protection pipe, complete all as specified and directed.
All as per item ser No 190here-in-before but connected with GI strip 25x4 mm complete all as specified and directed.
GS Engineers
HARISH SALES CORPORATION
R D Bansal
M/S sanjay and co.
GURU NANAK CONSTRUCTION CO.
His Construction Company
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .