Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.9 LAccepted-AOC 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L1 | Accepted-AOC Lowest Bidder, Hence accepted | |
| 2 | L2₹16.0 L+₹1.6 L (11.0%)Rejected-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L2 | Rejected-AOC higher quoted bidder | |
| 3 | L3₹19.7 L+₹5.3 L (36.8%)Rejected-AOC 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L3 | Rejected-AOC higher quoted bidder |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
21 Jul 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Phalodi
GE (AF) Phalodi
REPAIR/MAINT OF PERIMETER AREA SECURITY LIGHTS, WATCH TOWER LIGHTS, PILLAR LIGHTS AND CONNECTED ITEMS AT AF STN PHALODI
2022_MES_533380_1
8430/C/E8
Open Tender
Miscellaneous Works
Item Rate
180 days
GE (AF) Phalodi
Class E Cat b (i)
7 documents required · 7 mandatory
₹500
GE (AF) Phalodi
₹40,000
Yes
1 Sept 2022
24 Jun 2022
27 Jul 2022
24 Jun 2022
21 Jul 2022
8 Jul 2022
60 days
Amount
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for laying underground cable in soft/losse soil complete all as specified and directed.
Excavation in trenches, n exc 1.5 m wide and n exc 1.5 m in depth or n exc 10 Sqm on plan and n exc 1.5 m in depth & getting out, for laying underground cable in hard and dense soil complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cms thick in any type of soil complete all as specified and directed.
Removing excavated surplus material to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5m above the starting point complete all as specified and directed.
Material and labour for dry tibba sand in trenches cushioning to under ground cable spreading, levelling hand punning complete all as specified and directed. Note- Punned down thickness will be measured for payment purpose.
Material and labour for Cement Concrete 1:2:4 type B1 using 20mm graded stone aggregate for coping complete all as specified and directed.
Material and labour for Cement Concrete 1:4:8 type D2 using 40mm graded stone aggregate for pole base foundation complete all as specified and directed.
Supplying and laying reinforced precast concrete cable cover, Class LV, Type I, flat, size 250mm x 150mm x 40mm complete all as specified and directed.
Disconnecting and Taking out of old LT armored PVC cables from trenches of any size/core/any voltage grade from trenches for replacement all as directed.
Supply,laying ,connecting,testing and commissioning and jointing in replacement XLPE insulated, armoured, heavy duty electric cables with stranded aluminium conductor, 1100 volts size of cable 10 sqmm 2 core laid in trenches, ducts, pipes, drawn across the roads/paths/drains/along poles/walls/floors/equipment etc including jointing and testing complete all as specified and directed. NOTE :- (i) Sand cushioning ,cable protection cover,GI pipes,excavation and earth work shall be measured and paid seprately under items of Schedule "A"
All as per item No. 10 above but size of cable 16 sqmm 4 core
All as per item No. 10 above but size of cable 25 sqmm 4 core
Dismantling of existing unserviceable/cracks PCC poles of any size and type from its position from the site and taking away from site including necessary excavation and earth work in any type of strata,demolition of concrete, disconnecting of street light fitting etc all as specified and as directed.
Supply, erecting and fixing in replacement of cracked PCC poles, true vertical position of steel tubular pole, 9 mtr long complete with cast iron base plate, finial taper plug, bolt, nuts and screws as specified and of type 410 SP-31, conforming to relevant IS, including one primer coat of red oxide and two coats of aluminium paint and two coats of bituminous paint inside and outside of bottom portion up to 1.8 mtr length complete all as specified and directed. Make :-National tubing co ,Kanpur / Ridi poles,Varodara / Sohanlal & Sons Ghaziabad
Cutting of road / hardstanding upto a size not exceeding 20 cms in width and not exceeding 60 cms in depth for laying of LT UG cable protection piep line making good the disturbed portion so as to match existing finishing or with PCC 1:2:4 type C1 complete all as specified and directed.
M&L for preparation of surfaces, scraping of old paint of steel surface of poles and applying two coats of aluminium paint over a coat of red oxide primer of LT steel tubular pole 9 metre hight, single swan neck /double swan neck, Including fixing of reflection tape in altternate coloured of width 6" on poles 1.5 to 1.8 metre above the ground level including writing pole number with black letter under yellow circle complete all as specified and directed. Note :- The tape colour shall be as directed by Engr-in-charge.
M&L in replacement for PVC insulated weather proof two core 6 sqmm multistrand aluminium conductor for connection incl taking down UNSV cable complete all as specified and directed.
M&L in replacement for PVC insulated weather proof two core 4 sqmm multistrand aluminium conductor for connection incl taking down UNSV cable complete all as specified and directed.
S & F Adjustable thermal & magnetic release MCCB 4 pole 100 Amps, 36 KA rating,Ics = 100% Icu (Icu = 36 kA), 415 volts AC incl taking down UNSV MCCB complete all as specified and directed.
S & F MCB 4 pole 63 Amps, 10 KA rating, Four Pole, C curve, 415 volts AC incl taking down UNSV MCB complete all as specified and directed.
Supply and fixing in replacement of U/S Surge protector 10 KA for LED fitting complete all as specified and directed.
Supply and fixing in replacement of U/S Electronic Driver suitable for 45/48 Watts LED fitting complete all as specified and directed.
Supply and fixing in replacement of U/S Electronic Driver suitable for 60 Watts LED fitting complete all as specified and directed.
Supply and fixing in replacement of U/S Electronic Driver suitable for 90 Watts LED fitting complete all as specified and directed.
Supply and fixing in replacement of U/S Electronic Driver suitable for 120 Watts LED fitting complete all as specified and directed.
Dismantling and disconnecting electrical connection & taking out carefully old serviceable / unserviceable pole mounting brackets and GI band for street light fitting with MS clamps ,nut-bolt, street light fittings etc from PCC/Steel poles complete all as specified and directed.
S & F Double swan neck with GI pipe medium grade 32 mm dia bracket 2.0 mtr long by hydraulic pressed mechine bend to require arc shape and consists/welded in 125 mm dia of GI tube 30 cm long cap (for mounting on pole) and suitable size fixed with bolts,nuts and washers including drilling holes and grouting with the same for fixing bolts complite as required duly painted with two coat of aluminum paint over a coat of red oxide primer and fixing the removed from above item existing street light fitting complete all as specified and directed.
Supply and fix in replacement Intelligent, flexible & smart outdoor lighting control unit for automatic switch ON at dusk automatic switching OFF at Dawn with Astronomical Time Switch, high voltage and low voltage protection, 3 Pole / 230V For 12 KW load equally distributed over 3 phases. Minimum IP54 Degree of Protection complete all as specified and directed.
Supply and fixing in replacement of U/S flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated dia costing power coted in gray finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 150 W LED 5700K complete all as specified and directed. NOTE :- Cost of Necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires,security light /high mast light fittings etc should be deemed to be included in the unit rate quoted.
Supply and fixing in replacement of U/S flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coted in grey finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 120 W LED 5700K complete all as specified and directed. NOTE :- Cost of Necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires,security light /high mast light fittings etc should be deemed to be included in the unit rate quoted.
Disconnection of street light fittings and refixing,Material and labour in replacement for circuit /sub main wiring for junction box to street light fitting complete with 1.5 sqmm 3 core PVC insulated and PVC round sheathed multistranded copper conductor flexible industrial cable 1100 V grade complete all as specified and directed. NOTE :- Cost of Necessary tools and plants such as ladders, hydra for connection to street light fittings etc should be deemed to be included in the unit rate quoted.
LT Cable junction box outdoor shall be made out of Polycarbonate with glass fiber reinforced and size should be not less than 223mm x 293mm x 120 mm(upto Cable Size 35/50sq.mm). The Polycarbonate Junction Box shall be environment friendly, recyclable, halogen & silicon free, anti acid & anti corrosive. The Junction Box shall be rated for Degree of ingress Protection IP 66/69 in accordance with IEC 60529.Weatherproof, UV-resistant, rainwater-proof, temperature-resistant. The gasket material of junction box shall be Polyurethane and the gasket shall be internally embedded. The Junction Box shall be complies with requirements of the standards IEC 60998 - 1, IEC 60670 - 22 & IEC 60670 - 2 - 5. The Junction Box with Connectors or Terminal Trip or Bus Bar. The manufacturer of Junction Box / Enclosure shall submit a copy of IEC Certificate . For better safety the Polycarbonate enclosure and shall be fire retardant & self - extinguishing in accordance with IEC 60695 - 2 - 11, DIN VDE 0304 Part - 3, UL Subject 94 for Flammability V-2. It should be tested at Glow Wire test for 960 degree Centigrade & Current Carrying Capacity upto 102Amps. The impact strength of Polycarbonate enclosure / boards i.e. the Degree of protection against mechanical load shall be in accordance with EN 50298 - 98 for IK 08 including one No. 4 pole connector and one no. MCB SP 'B' curved 6-32 Amp and chromium plated clamps and nut bolts, Glands complete all as per manufacturer’s instructions. Make : Cat Part :- KF 3500 B of Hensel/Siemens/GE Power/Rittal or equivalent.
M&L in replacement of FRP junction box of Make : Sintex, Model : GS-JB-2520, size internal 250 x 200 x 105 and External 295 X 255 X 120 mm having 4 Nos aluminium bus bar of size 20X4 mm fixed on epoxy insulators with MCB SP 6 Amps,fixed on the pole with clamps,nut bolts etc. complete all as specified and directed.
S&F in repairs for rigid non-metallic PVC conduit of 20 mm dia heavy duty alongwith street light poles for wire from junction box to light fittings including fixing arrangement complete all as specified and directed.
Supply and fix replacement in Repair MCB SP , 240 volts 6 amps in the existing FRP. Make : Legrand, Model : RX3 MCBs Cat No : 402431, 6 A, 'B' Curve complete all as specified and directed.
Supply and fixing/replacing in repair Solar batteries for Solar PV Power System of rating 12 v 200 Ah, with container and lids made of Polypropylene Co Polymer of rating 12 v, 200 Ah - Manufactured with high corrosion resistant and robust spine technology with positive plate of tubular low antimony and negative plate flat Ah effciency of above 90% and Wh efficiency above 80% complete all as specified and directed.
Supply Installation Testing and Commissioning in replacement of Lithium based Solar LED Security light System with built in Battery and PV Panel and LED lamp in FRP/Aluminium body including taking down of old unserviceable light fitting of any size/capacity complete all as specified and directed.. System Comprises Followings”. 1. 1. PV Panel 30W Monocrystalline. 2. Lithium Cell for back up 15.4AH with inbuilt BMS. 3. High brightness W-LED lamp 16W, CRI>700, CCT6500K. 4. Microcontroller based charge controller cum driver with automatic dimming function, Dusk to Dawn Operation. 5, Working temperature: (-) 10°C to (+) 55°C. System should be supplied with adjustable MS clamp and 40mm dia arm suitable for pole/wall mounting complete all as specified and directed.
Material & Labour in rectification of LT cable, fault existing / as and when occurs with diagonising equipments as applicable, and by joining with suitable LT cable joint kit complete all as specified and directed. Note: (a) Diagonising equipments, Skilled labour, Machinaries for excavation and refilling earth work are to be provided / arranged by the contractor at his expenses. (b) If LT cable fault occurs in Road crossing then Road cut surface to be made good after rectification work. (c) GI pipe utilized fo cable protection under Road/ Over wall will be measured and paid separately.
Supply and laying/ fixing GI tube, light grade, 50mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light polesor as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed.
Material and Labour in repositioning/ realigning directional changes of Security lights affected by High speed wind / Desert Storm over the same existing poles in specific locations complete all as specified and directed. Note: Skilled Labour, Tools as required will be provided by Contractor.
Material and Labour in altering height of security light elevation over the same existing poles in specific locations complete all as specified and directed. Note: Skilled Labour, Tools as required will be provided by Contractor.
Material and labour for earthing complete with 60cm x 60cm x 6mm thick GI plate electrode buried in ground vertically not less than 2.25mtrs deep below ground level with top edge of the plate not less than 1.5mtrs below ground level with Galvanized earth lead wire as earthing lead with bolts, nuts, checknuts and washers of galvanised iron or steel all as shown in Electrical plate No. 3 of SSR Pt I 2009 connected to earthing test point all as specified including testing on completion including necessary excavation and earth work (in any of strata) providing charcoal dust, salt mixed with fine sand in continuous layers, PCC (1:3:6 ) type C1 (using 20mm graded stone aggregates) in chamber, Precast 50 mm thick in cement (1: 2:4) type B1 (using 20mm graded stone aggregates) with CI frame with cover, 20mm dia bore medium grade GI watering pipe furnel etc fixing of GI Pipe 40 mm bore, medium grade, protection for earthing strip from earth pit to test point complete all as specified and directed.
Supply and fixing of 45 watt Inverter LED Street Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case of power failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15% complete all as specified and directed.
Supply and fixing of 60 watt Inverter LED Street Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case of power failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15% complete all as specified and directed.
Supply and fixing energy efficient LED street light fitting of 60 Watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency more than 100 lumens / watt individual LED's should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed.
Supply and fixing in replacement of U/S flood light luminaire of HPSV/MH,with inverter LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coted in grey finish,high power LED with IP 66 protection, fins are provided on housing ,heat resistant tempered glass for protection with 5 kv surge protection of 60 W LED as specified and directed. NOTE :- Cost of Necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires,security light /high mast light fittings etc should be deemed to be included in the unit rate quoted.
Notes: - (i) Contractor should depute Electrician and helper and other required equipments such as transportation,hydra,minor excavation etc to attend the Faults / Complaints on daily basis as per complaint trace out and no extra payment will be made out on this account and as directed by Engineer-in-charge. (ii) Contractor / Supervisor will collect complaint of Electric faults,cable faults,Security light faults,No light faults from concern JE on daily basis and will complete them the same day. (iii) Contractor should provide equipments like Excavation Tools, Discharge rod, Tester, Test lamp, Multi meter, Side plier & related essential tools, Industrial Safety helmet, Hand gloves,safety materials etc on his own arrangement as per site requirement for rectifying the complaint and no other payment will be made for the same.
KRISHNA CONSTRUCTION COMPANY
M/S SOLANKI GENERAL SUPPLIERS
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .