| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.2 LAccepted-AOC 00 CHAH KATHAUTI CHAH KATHAUTI MATHURA UTTAR PRADESH 281001 | MATHURA | UTTAR PRADESH | 281001 | L1 | Accepted-AOC AOC | |
| 2 | L2₹39.2 L+₹1.2 L (3.14%)Rejected-Finance | L2 | Rejected-Finance Not being L1 | |
| 3 | L3₹39.8 L+₹1.8 L (4.71%)Rejected-Finance | L3 | Rejected-Finance Not being L1 | |
| 4 | L4₹43.8 L+₹5.8 L (15.2%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L4 | Rejected-Finance Not being L1 | |
| 5 | L5₹44.4 L+₹6.4 L (16.8%)Rejected-Finance | L5 | Rejected-Finance Not being L1 |
Tender Value
₹48.9 L
EMD Value
₹97,760
Closing Date
21 Jun 2023, 6:00 pmClosed
GE (I) Navy Jamnagar
INS Valsura, Jamnagar - 361 150
Special repairs to MCPO/ CPOs Mess (Bldg No. P-70) at INS Valsura, Jamnagar
2023_MES_598761_1
8665/VAL/E8
Open Tender
Civil Works
Item Rate
180 days
GE (I) Navy Jamnagar
Please refer tender documents
6 documents required · 6 mandatory
₹500
GE (I) Navy Jamnagar
₹97,760
Yes
21 Jul 2023
26 May 2023
23 Jun 2023
26 May 2023
21 Jun 2023
9 Jun 2023
Amount
Taking down cement plaster of any description including racking out joints, hacking for key scrubbing down with water etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of brickwork or stone/boulder masonry, built in cement mortar including all quoins, arches, pillars, etc and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Demolition of cement concrete (un-reinforced) in ground floor and paving not exceeding 15 cm thick (above or below ground level) and removal of entire debris as ordered outside MoD land complete all as directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for (reinforcement cut as required to faciliate demolition) including removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Dismantling of wrought iron or mild steel work of any description and from any position not otherwise provided for in this Schedule (BOQ), complete all as specified and as directed.
Dismantling plain or corrugated steel sheeting including ridges, any gauge, thickness, including Nainital or similar pattern roof coverings and stacking at site where directed complete all as specified & as directed.
Dismantling mangalore pattern roofing tiles with ceiling tiles or slate roofing including ridges and stacking at site where directed complete all as specified & as directed.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing), stacking serviceable tiles at site and removal of entire debris as ordered outside MoD land complete all as specified and as directed.
Taking down chowkats or frames exceeding 1.5 Sqm but not exceeding 4.0 Sqm each with shutters (without taking off shutters from frame) and refixing in the same opening as ordered after other repair works are carried out complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description not exc 1 Sqm each, complete all as specified and as directed.
Taking down shutters (including fittings & fixtures) of any description exc 1 Sqm but not exc 2 Sqm each, complete all as specified and as directed.
Taking down shutter of any description not exceeding 1 Sqm each and refixing in same opening as ordered after other repair works are carried out including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as directed.
Taking down shutter of any description exc 1 Sqm and not exc 2 Sqm each and refixing in same opening as ordered after other repair works are carried out including easing and adjusting of shutter as required including renewal of unserviceable screws complete all as directed.
Excavating in trenches, not exc 1.5 metre wide and not exc 1.5 metre in depth, for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. laying cables, pipes, etc. not exc 10 Sqm on plan & not exc 1.5m in depth and getting out in soft/ loose soil complete all as specified and as directed.
Returning, filling in trenches, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick in soil complete all as specified and directed.
Removing excavated surplus soil to a distance not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as directed.
M&L for post construction Anti Termite Treatment of soil under existing floors using emulsion @ one litre per hole, 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 (1 cement: 2 coarse sand) to match the existing floors complete all as specified and as directed.
M&L for post construction Anti Termite Treatment at points of contact of wood work by chemical emulsion (in oil or kerosene based solution) at the rate of 0.50 litres per hole by drilling 6mm dia holes at a downward angle of 45 degree at 150 mm centre to centre and sealing the same to match with the existing finish complete all as specified and as directed.
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks, exceeding 10 cm in width and setting in cement mortar 1:6 complete all as specified & as directed.
M&L for factory made pre cast cement concrete 1:3:6 type C1 (using 20 mm graded crushed stone aggregate) block masonry with solid blocks or slabs, 10 cm thick (with plain or interlocking joints as directed) and setting in cement mortar 1:4 in walls complete all as specified & as directed.
M&L for reinforced cement concrete 1:1½:3, type A1, Nominal mix (using 20mm graded crushed stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like including necessary formwork and scaffolding complete all as specified and as directed. Note : Reinforcement shall be measured and paid for separately.
M&L for RCC 1:2:4, type B1 (using 20mm graded crushed stone aggregate) as in chajja, roof projection etc in any description up to 6 metre height from FFL including necessary formwork and scaffolding complete all as specified and as directed. Note: (i) Quoted rate shall deemed to be inclusive of form work, scaffolding, safety belt etc. (ii) Reinforcement shall be measured and paid for separately.
Supply only Integral Water Proofing Compound (ISI Marked).
M&L for Second class hard wood battens spaced at 30cm centre to centre, clean sawn, cross sectional area exceeding 15 sqcm but not exc 25 sqcm, including taking down old unserviceable/ decayed battens, complete all as specified and as directed.
Dismantling carefully existing serviceable second class hard wood battens of cross sectional area exceeding 15 sqcm but not exc 25 sqcm spaced at 30cm centre to centre, clean sawn, and re-fixing the same at old or new position spaced at 30cm centre to centre, complete all as specified and as directed.
Dismantling carefully existing serviceable timber scantlings 40 sqcm and over in section, in any position, unframed work and re-fixing the same at old or new position complete all as specified and as directed.
M&L for 20mm thick Second Class hard wood boarding, planed one side with butt joints and fixed with nails in any situation (expect flooring and skirting), complete all as specified and as directed.
S&F factory made 35 mm thick second class hard wood glazed and skeleton door shutter open rebated and prepared to receive glass, guage etc edges of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (a), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats, complete all as specified and as directed.
S&F factory made 30 mm thick second class hard wood glazed and skeleton window shutter open rebated and prepared to receive glass, guage etc edge of framing plain chamfered or rounded fitted with cut and mitred beads for securing guage etc size of members of shutter as specified in SSR Part I Section 8 clause 8.24 (b), kiln seasoned and chemically pressure treated, supplied and fitted to chowkats complete all as specified and as directed.
S&F factory made single extruded WPC (Wood Polymer Composite) solid door/window / Ceosetory windows & other Frames/ Chowkhat of size 45 x 70mm comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 Kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/sqmm, modules of elasticity 900 N/sqmm and resistance to spread of flame of Class A category with property of being termite/ borer proof, water/moisture proof and fire retardant and fixed in position with MS hold fast/ lugs/ SS dash fasteners of required dia and length complete as per direction of Engineer-in-Charge. Note: MS hold fast/ lugs/ SS dash fasteners shall be measured and paid for separately.
S&F factory made single extruded WPC (Wood Polymer Composite) solid decorative type flush door shutter of size 30mm thick comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibres (wood powder/ rice husk/ wheat husk) and non-toxic additives (maximum toxicity index of 12 for 100 gms) having minimum density of 650 Kg/cum and screw withdrawal strength of 1800 N (Face) & 900 N (Edge), minimum compressive strength 50 N/sqmm, modulus of elasticity 850 N/sqmm and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant. WPC to be laminated with PVC foil of minimum 14 microns thick of approved design pasted with hot melt adhesive on both faces of shutter and fixing with stainless steel butt hinges of required size with necessary full body threaded star headed counter sunk S.S screws, all as per direction of Engineer -In- Charge. Note: Stainless steel butt hinges and necessary SS screws shall be measured and paid for separately.
S&F 200 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 125 mm long aluminium, anodised, barrel tower bolt (ISI marked) of extruded section and fixed.
S&F 75 mm size butt hinges, medium weight cold rolled mild steel and fixed .
S&F 100 mm size stainless steel butt hinges (ISI Marked), medium weight fixed with full body threaded star headed counter sunk S.S screws all as directed.
S&F 125 mm size extruded aluminium alloy handle (ISI Marked), cast type, anodised and fixed.
S&F 150mm size extruded aluminium alloy handle (ISI Marked), fabricated type, anodised and fixed.
S&F in repairs stainless steel drapery rod of 25mm dia (in lengths as directed) with & including stainless steel decorative SS bulb type finial at both ends / SS end socket and pair of stainless steel brackets fixed at both ends with PVC rawl plug & steel screws on walls/beam complete all as specified & as directed.
S&F in repairs XPM design aluminium alloy wire cloth, 0.45mm nominal dia of wire and average width of aperture 1.40mm and fixed with aluminium wire staples along with wooden beads complete all as specified and as directed.
S&F aluminium powder coated (minimum thickness of powder coating 50 micron) frames and shutters for doors, windows and ventilators with one or more rebates including joining cleat for fixing, anodised aluminium snap on beading, neoprin gasket etc. complete all as specified and as directed.
S&F mild steel bands, straps, supports or stays for rainwater, ventilating pipes, including bolts, if required hooks (stay), heavy, for large gates, hook and pintle hinges, large hasps and staples, chains, hand made sliding bolts, clamps, hold fasts, wall ties, hooks for hanging fans, plain angle cleats for securing purlins to wood trusses or rafters, knee piece inserts, two way and three way straps, plate washers and similar small articles conforming to Fe-290 (Gde-E-165) complete all as specified and as directed.
M&L for mild steel TMT bars 10 mm dia and over cut to length, bent to shape required, including cranking, bending spirally or hooping for columns, hooking ends and binding with mild steel wire (annealed) not less than 0.9 mm dia complete all as specified & as directed.
S&F rolled mild steel sections as in main and cross beams, hip and jack rafters, purlins where connected to common rafters and running rails and guides for sliding doors, steel ladders etc fixed with angle cleats or other connecting plates etc conforming to Fe-410 W (Gde E-250) quality-A complete all as specified and as directed.
S&F GI chicken wire mesh cut to size made to shape as ordered including fixed to walls with nails for receiving the plaster complete all as directed. (Note: Weight of GI chicken wire mesh shall be 140 to 180 grams /Sqm)
S&F stainless steel (Grade-304) railing made of hollow tubes, channels, plates etc, including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, including fixing the railing with necessary accessories & stainless steel dah fasteners, stainless steel bolts etc, of required size for gate with suitable arrangement as per approval of Engineer-in-Charge. (for payment purpose only weight of stainless steel members shall be considered exclusing accessories such as nuts, bolts, faterners etc).
Dismantling wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards / slabs / blankets any thickness, including cover fillets and S&F new 6 mm thick calcium silicate board of siliceous and calcareous material reinforced with cellulose fibre board with frame work with screws fixed to false ceiling with and including galvanised iron powder coated (white) snap Grid of size 600x600 mm with main 'T' and cross 'T' having web 25mm, flange 35mm, thickness 0.70mm, wall angle having web/flange 25mm each, 0.70mm thick fixed with soft cleats having web 25mm, flange 25mm and thickness 1.8mm using 4mm dia GI wire and level clip @ 1200mm centre to centre with PVC rawl plug with & including 6mm thick calcium silicate board as described fixing with clips etc. and ceiling board fixed as per manufacturer's instructions with & including two coats of oil emulsion distemper (OBD) over a coat of primer on ceiling board with & including taking down existing electrical fittings/fixtures and wiring in ceiling and re-fixing the same to its original position or different locations, after completion of ceiling work including testing on completion as ordered complete all as specified & as directed.
S&F 0.63 mm thick galvanised, corrugated mild steel sheeting with two corrugations side lap, fixed with L-type or J-type or cranked hook bolts and washers, in roofs, walls etc. with grade of zinc coating 275 complete all as specified and as directed.
All same as per serial item No. 46 here-in-above, but except sheeting, any thickness. Note : MS Sheets obtained serviceable vide serial item No. 6.00 here-in-before shall be reused under this item.
S&F 0.63 mm thick Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 complete all as specified and as directed.
M&L for Roof tiles, Mangalore pattern, interlocking at side joints, laid dry including cutting holes through tiling for pipes and making good the disturbed surface to its original specification complete all as specified and as directed.
All same as per serial item No. 49 here-in-above, but except roof tiles. Note : Roof tiles obtained serviceable vide serial item No. 7.00 here-in-before shall be reused under this item.
M&L for Ridges or hip tiles to suit Manglore pattern roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and as directed.
M&L for 75 mm thick plain cement conctere 1:3:6, type C1 (using 20 mm graded crushed stone aggregate) as in plinth protection, finished the surface even and smooth without using extra cement, complete all as specified & as directed. Note : Plinth protection shall be of width as directed and shall be laid with an outward slope of 1:40 in alternative bays not exceeding 2.5 meter in length. Joints of 6 mm wide and 10 mm deep shall be provided along the wall and bays and same shall be filled with bitumen mastic filling comprising 1 part of heated bitumen Blown grade any penetration and 3 parts of sand (all by weight). Quoted rate of this item shall deemed to include this provision.
M&L for 25mm thick plain cement concrete 1:2:4 type B0 (using 12.5mm graded crushed stone aggregate) as in levelling course of floor finishes complete all as specified and as directed.
M&L for 18 to 20mm thick machine cut mirror polished Kota stone slab of minimum size 550 x 550mm, laid in floors over & including screed bed or bedding layer of 20mm thick in CM 1:6 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. Note : Quoted rate shall deemed to be inclusive of cement screed bed/bedding layer.
M&L for 18 to 20mm thick machine cut mirror polished Kota stone slab on vertical surfaces such as riser of steps, skirting, dado and pillar, laid over & including 10mm thick rendering (as screed bed) in cement & sand mortar 1:4 and jointed with grey cement slurry mixed with pigment to match the shade of the slab with true & uniform joints including rubbing and mirror polishing complete all as specified & as directed. Note : Quoted rate shall deemed to be inclusive of rendering (as screed bed).
M&L for double charged vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (shade & pattern as approved by GE), area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, in floors etc, set and jointed in neat cement slurry, laid & fixed using spacers 5mm thick and including epoxy grouting of tiles, over & including 15mm thick screed bed in cement & sand mortar 1:6, complete all as specified and directed. Make of material for epoxy grouting : Fosroc / Dr. Fixit / Pidilite / Magnifico / Magicrete or equivalent as approved by GE.
M&L for double charged vitrified ceramic tiles 10mm thick (square/rectangular), polished, coloured (shade & pattern as approved by GE), area of each tile exceeding 0.42 sqm but not exceeding 1.00 sqm, on vertical surfaces such as skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10mm thick screed bed in cement & sand mortar 1:4, size of tiles as directed by GE to match the size of vitrified tiles provided in floor under respective item in this Schedule, complete all as specified and as directed.
M&L for non skid ceramic tiles (coloured) 7 to 8mm thick (square/rectangular) area of each tile exceeding 0.06 sqm but not exceeding 0.11 sqm as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 15mm thick screed bed in cement & sand mortar 1:6 complete all as specified and as directed.
M&L for glazed ceramic coloured tiles, 7 to 8mm thick, area of each tile exceeding 0.11 sqm but not exceeding 0.18 sqm (i.e. 600mm x 300mm or as directed by Engineer-in-Charge), on vertical surfaces such as dado, skirting etc., set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over & including 10 mm thick back coat in CM 1:4 complete all as specified and as directed. Notes for Srl items Nos 56 to 59 : (i) Quoted rate shall deemed to be inclusive of cement screed/ plaster. (ii) Colour of tiles shall be got appproved from GE before procurement for the work.
M&L for 16 to 18 mm thick granite slab (Jet Black) work (table rubbed and polished) in steps, jambs, pillars, window cills, cooking platforms, wash basin counter and the like, set in cement mortar 1:4 including pointing in white cement 1:2 using marble dust with admixture of pigment to match with shade of granite over & including 15mm thick screed bed in cement mortar 1:6 complete all as specified and as directed.
M&L for rendering 15 mm thick in CM 1:6 on stone masonry surfaces or surfaces other than fair faces of brick work of walls, finished even & smooth without using extra cement complete all as specified and as directed.
M&L for rendering 20mm thick in cement mortar 1:4 on stone masonry surfaces or surfaces other than fair face of brick work of walls in patches and scattered places mixed with WPC @ minimum 2% by weight of cement or as per manufacturer's instructions and finished the surface even and smooth without using extra cement complete all as specified and as directed. Note : WPC shall be measured and paid for separately as 'Supply only'.
M&L for rendering 10 mm thick in cement mortar 1:3 on fair faces of brick work or concrete surfaces in ceiling, finished even and smooth without using extra cement complete all as specified and as directed.
M&L for preparation of newly plastered / unplastered surfaces of ceilings and applying three coats of white wash complete all as specified and as directed.
M&L for preparation of old surfaces of ceilings including scraping down smoke soot, moulds, moss and efflorescent salts, trading oil and greasy spots etc by hand held sander / long handle sander including cornices, pilasters etc (Plastered or unplastered surfaces) and applying two coats of white wash complete all as specified and as directed.
M&L for preparation of new plastered surfaces of walls and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over a coat of primer over & including 1mm thick white cement based wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment including cleaning of mortar drops, smoke soot, moulds, moss, efflorescent salts, trading oil, greasy spots etc and preparation of plastered surfaces and applying two coats of oil emulsion distemper (OBD) of approved shade/tint over & including 1mm thick white cement based wall care putty on walls complete all as specified & as directed.
M&L for preparing newly plastered surface of walls and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm as per manufacturer's instructions over & including 1mm thick white cement based wall care putty complete all as specified & as directed.
M&L for complete removal of existing treatment by meachanical means (any no of layers), wahsing, rubbing down and stopping of distempered and painted surface of wall and applying two coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of shade as approved by Engineer-in-Charge (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over 1mm thick white cement based wall care putty as per manufacturer's instructions over & including 1mm thick white cement based wall care putty complete all as specified & as directed.
Hacking out old broken glass (any thickness) and size from wooden frame glazed with putty or fixed with wooden beads complete all as directed.
S&F 4mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections not exceeding 0.5 Sqm in each pane complete all as specified & as directed.
S&F 5mm thick sheet glass, ordinary quality and glazing with oil putty or wooden beads or fixed to aluminium sections exceeding 0.5 Sqm in each pane complete all as specified & as directed.
S&F 4mm thick figured glass, pin headed type and glazing with oil putty or wooden beads not exceeding 0.5 Sqm in each pane all as specified & as directed.
M&L for two coats of 1st quality synthetic enamel paint of approved tint over a coat of pink primer on new wooden surfaces of any description over 10 cm in width or girth including necessary preparation of new wooden surfaces complete all as directed.
M&L for preparation of old painted steel and iron surfaces of any description over 10 cm in width or girth and applying two coats of 1st quality synthetic enamel paint of approved tint all as specified & as directed.
M&L for preparing old painted wooden or wood based surfaces by complete removal of existing treatment by mechanical means (any no of layers) and applying French polishing two or more coats until high glossy finish is obtained on wooden or wood based surfaces of any description, width or girth including a coat of wood filler, complete all as specified and as directed.
Taking down or up damaged/ old GI pipe of 15 mm bore and S&F new 15 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Taking down or up damaged/ old GI pipe of 20 mm bore and S&F new 20 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
Taking down or up damaged/ old GI pipe of 25 mm bore and S&F new 25 mm bore galvanized steel water tubing medium grade (ISI marked) with all new fittings (ISI marked) fixed to wall and ceiling or laid in floors complete all as specified and as directed.
S&F in repairs 20mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs 25mm bore Gun metal gate valve (ISI marked) with iron wheel head, screwed both ends for iron pipe, complete all as specified & directed.
S&F in repairs ball valve, high pressure of PTMT with epoxy coated Aluminium rod & high density plastic ball, screwed for iron pipe or brass ferrule of 20 mm bore and fixed (minimum weight 210 gms) complete all as specified and as directed..
S&F in repairs 15mm bore bib tap with wall flange, fancy type, cast copper alloy, chromium plated, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 8506 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore two way bib tap fancy type, brass, chromium plated with flange, screwed for iron pipe or for brass ferrule complete all as specified and as directed. Make: Prayag Cat No. 8512 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs health faucet CP Brass body with wall hook and 1 metre SS braided rubber hose pipe and wall hook mounted type suitable for fixing to supply pipe of 15mm bore complete. Make: Prayag Cat No. BEA-85 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore pillar tap, Swan neck, fancy type, CP cast copper alloy, with capstan heads, with long screwed shanks and fly-nuts, screwed down high pressure, screwed for iron pipe complete all as directed. Make: Prayag Cat No. 8914 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs 15 mm bore angle cock with wall flange, chromium plated brass, screwed both for iron pipe or brass ferrule complete all as directed. Make: Prayag Cat No. 8510 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs Brass chromium plated tubular towel rail, 20mm dia, D type, 50cm long between flanges complete all as directed. Make : Prayag Cat No BA-01 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs CP Brass toilet paper holder with flap guard complete all as specified and as directed.
S&F in repairs PVC connections 15mm dia, 450mm long with PTMT nuts & washers at both ends.
S&F in repairs grating square 140 mm size of stainless steel and fixed complete all as specified & as directed.
S&F in repairs 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2, fixed to wall/ ceilings or in floors etc for drain/waste pipe for WHB/Sink etc.complete all as directed.
S&F in repairs vitreous china oval shape counter sunk wash hand basin (white) of size 560mm x 470mm x 190mm with & including 32 mm dia PVC waste pipe and 32mm chromium plated brass waste fitting with long screwed shanks and fly nuts, flange end bedded in red lead cement & other end fixed complete all as specified & as directed.
S&F in repairs vitreous china wash down water closet pan (Pedestal pattern), white, including connection to drain (or outgoing pipe) and to flushing pipe, anti-sypohonage pipe etc., with plastic WC seat cover (white) closed pattern with flat bottom and cover and mild steel chromium plated or aluminized hinging device, complete all as specified & as directed.
S&F in repairs vitreous china urinal, half stall type, white including providing & fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with & including 60 mm long brass screws, pointing around urinal back in cement, with & including CP brass spreader, PTMT grating and union for discharge pipe including waste pipe of polythelene of low or high density or PVC 32mm dia, complete all as specified and as directed.
S&F in repairs 10 liters capacity PVC valveless, syphonic action type, flushing cistern, low level, white with inlet ball valve, float and handle including brackets and flush pipe of polyetylene of low or high density or 32 mm dia PVC connection pipe complete all as specified and as directed.
Dismantling of existing any type & 1000 litres capacity water storage tank fixed in any description and S&F new 1000 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
Dismantling of existing any type & 500 litres capacity water storage tank fixed in any description and S&F new 500 litres capacity (white colour) rotational moulded polythene water storage tank, (cylindrical vertical with close top) triple layer colour white both inside and outside with top cover hoisted and fixed in position where ordered and making necessary connections for fixing inlet, outlet & over flow pipe & provision of wash out pipe etc. complete as specified in SSR Part-I and as directed.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed.
S&F in repairs 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.
S&F in repairs 110 mm bore PVC (SWR) pipes single socketed in any length with rubber rings joints/ solvent cement joints, laid in trenches or in floors, complete all as specifed & as directed.
S&F in repairs 110mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints / solvent cement joints fixed to walls, complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) bends any radius with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) branch piece (Single Y) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 75 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F 110 mm bore PVC (SWR) junction single (single T) equal or unequal with access door including jointing the same with solvent cement complete all as specified & as directed.
S&F PVC (SWR) floor trap plain including jointing with solvent cement, diameter of outlet 75mm, complete all as specified & as directed.
M&L for PVC (SWR) gully trap 125/110 mm including jonting the same with solvent cement complete all as specified & as directed.
E&M Items: Taking down carefully existing unserviceable/perished surface conduit/ concealed conduit/ batten/ casing caping aluminium/ copper point wiring any type for light, fan, bell, socket, power point etc complete including all fixtures and fittings such as batten/conduit/casing caping, etc and making good the disturbed surfaces of wall, floors, ceiling, etc to match with the adjoining surfaces, complete all as specified and as directed.
M&L for point wiring for one light/fan/bell/buzzer point controlled by one, one way switch with 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 1.50 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour to common earth and connected to earth dolly laid/drawn into and including non-metallic rigid PVC concealed conduit (medium duty, ISI marked, not less than 20mm dia) with all fittings such as tee, bends, etc all as per IS, terminated in & including new sheet metal box, terminal plates with all accessories, concealed MS box/ PVC modular box with cover suitable for mounting fittings like switches, sockets, regulators etc with and including 3mm thick phenolic laminated sheet top cover, complete all as specified and as directed. Note : Cost of cutting/leaving forming chases for conduits, sinking for boxes and making good in CM 1:4 and applying suitable matching painting as required shall deemed to be included in quoted rate of this item.
All as per serial item No. 111 here-in-before but for one 3 pin 5/6 Amp modular switch socket on same board with other switches.
All as per serial item No. 111 here-in-before but for one 3 pin 5/6 Amp modular switch socket on independent board.
All as per serial item No. 111 here-in-before but for AC Metal Socket on independent board with 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) including 4 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade (ISI marked) as continuous earth wire in green colour.
S&F in repairs modular switch, single pole, one way, 6 Amp, 1 module with all accessories complete all as directed.
S&F in repairs modular switch, single pole, one way, 16 Amp, 1 module with all accessories complete all as directed.
S&F in repairs molular socket 6 Amp, 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs modular socket multipurpose 6 / 16 Amp - 2/3 pin combined, 2 module with all accessories complete all as directed.
S&F in repairs modular type TV socket outlet modular type, 1 module complete.
S&F in repairs modular type RJ 11 Telephone socket, 1 module complete.
S&F in repairs 20 mm dia rigid non-metallic PVC conduit (heavy duty, ISI marked) exclusive of boxes (junction/ terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends, etc and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. complete all as specified and as directed.
M&L for metal flush boxes concealed for mounting TV /Telephone socket etc including logic modular plates and surrounds of suitable size including dismatling existing box.
S&F in repairs ceiling rose surface bakelite White/ Ivory/ Urea finish 50mm dia three terminals including PVC square mounting block & electric wiring connection complete all as specified and as directed.
Taking down existing light fitting of any description & fixed in any position and S&F new 20 Watt wall mounted 4 ft glaze LED batten CCT(K) 6500, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No.LGLZ01X020XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fitting of any description & fixed in any position and S&F new 10 Watt wall mounted 2 ft glaze LED batten, CCT 6500K, high quality design, aluminium extruded with decorative end caps fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No. LGLZ01X010XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing light fitting of any type & fixed in any position and S&F new 36 Watt LED panel light fitting, recess/ pendant mounted 2ft x 2ft panel with white powder coated CRCA housing and full mounted acrylic diffuser, the CCT should be 6500K, fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make Jaquar Cat No. LULTSLS036XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down existing street/ security light fitting of any type & fixed in any position and S&F new 45 Watt LED street/ security light fittings in aluminium pressure die cast housing with toughened glass cover (IP 66 protection), having CCT 5700K and Sytem lumen efficacy >120 Lm / W, fixed on walls or steel/concrete pole at any height including making connection from ceiling rose/ Junction Box to light fitting with and including three core 1.5 Sqmm cable multistranded copper conductor PVC insulated & PVC sheathed, 1100 V grade of required length fixed as per manufacturer's instructions and making necessary electrical connections and testing on completion complete all as specified and as directed. Make: Jaquar Cat No. LSRT01S045XC or equivalent in makes mentioned in Appendix 'B' here-in-after.
Taking down carefully existing Bulb with holder and refixing the same at old or new position after repair work complete including making connections & testing on completion to the satisfaction of Engineer-in-charge.
Taking down carefully existing Decorative light fittings of any type/ Watt and refixing the same at old or new position after repair work complete including making connections & testing on completion to the satisfaction of Engineer-in-charge.
Taking down carefully existing Chandelier (Jhoomer) fixed on ceiling after necessary electrical disconnection, keep in the safe place as directed by EIC and refixing the same in existing / different location as ordered after repair work is carried out in all respects & making necessary electrical connections & testing on completion to the satisfaction of Engineer-in-charge.
Taking down carefully existing ceiling fan of any make or size with down rod and refixing the same after minor repair work i.e. cleaning, greasing, blade leveling etc. complete with down rod and connecting with & including new 3 core 1.5 sqmm copper conductor flexible cable from ceiling rose to fan with all accessories complete all as directed.
S&F in repair modular step type fan regulator 120 W, 2 module, AC, 230V, electronic complete all as specified and as directed.
Taking down carefully existing Exhaust fan of any make or size and refixing the same after minor repair work i.e. cleaning, greasing, blade leveling etc. complete and connecting with & including new 3 core 1.5 sqmm copper conductor flexible cable from ceiling rose to fan with all accessories complete all as directed.
Taking down carefully existing Split/ Window type AC of any capacity and fixed in any position, distmantling outdoor unit & indoor unit with all piping & wiring carefully and keep the same in safe place and refixing the same in existing location including refrigerent gas recharge/ suction as ordered after repair work is carried out in all respects, fixed all piping, making necessary electrical connections including testing on completion for smooth working to entire saticfation of Engineer-in-Charge, complete all as directed.
S&F in repairs single pole and neutral enclosure with a two pin and earth plug and socket complete 240 V with one Single Pole MCB 20 Amps, 'C' Curve complete all as directed.
S&F in repairs triple pole and neutral enclosure with a three pin and earth plug and socket complete 415 V with one Triple Pole MCB 63 Amps, 'C' Curve complete all as directed.
S&F in repairs triple pole and neutral enclosure with a three pin and earth plug and socket complete 415 V with one Triple Pole MCB 32 Amps, 'C' Curve complete all as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, VTPN, TPN, Vertical, 8 Way, flush mounted & surface mounting, suitable for fixing 3 Pole / 4 Pole MCCBs & MCBs, 415 Volts with 200 Amps rated bus bar, DB fitted with bus bar neutral links blank plates, fitted with and including MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with Thermal Magnetic Protection - 01 No., complete all as specified and as directed. Make of DB :- Legrand Cat No. 5077 52 or equivalent in makes mentioned in Appendix 'B' here-in-after. Make of MCCB :- Legrand Cat No. 4200 97 or equivalent in makes mentioned in Appendix 'B' here-in-after. Note : (i) Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) Quoted rates shall be inclusive of DB & MCCB as above. (iii) DB & MCCB of same make shall be provided.
S&F in repairs Distribution Board (DB) sheet metal enclosure, VTPN, TPN, Vertical, 4 Way, flush mounted & surface mounting, suitable for fixing 3 Pole / 4 Pole MCCBs & MCBs, 415 Volts with 200 Amps rated bus bar, DB fitted with bus bar neutral links blank plates, fitted with and including MCCB, 4 Pole, 125 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with Thermal Magnetic Protection - 01 No., complete all as specified and as directed. Make of DB :- Legrand Cat No. 5077 50 or equivalent in makes mentioned in Appendix 'B' here-in-after. Make of MCCB :- Legrand Cat No. 4200 96 or equivalent in makes mentioned in Appendix 'B' here-in-after. Note : (i) Cost of cutting/leaving forming chases for sinking for DB and making good in CM 1:4 shall deemed to be included in quoted rate of this item. (ii) Quoted rates shall be inclusive of DB & MCCB as above. (iii) DB & MCCB of same make shall be provided.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 4 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs Distribution Board (DB) sheet metal enclosure, SPN, 8 way with 200 Amps rated bus bar, double door, 240 Volts, suitable for fixing MCBs, fixed in concealed or on wall as per site requirement, complete all as specified and as directed.
S&F in repairs MCCB, 4 Pole, 160 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal Magnetic Protection complete all as directed. Make :- Legrand Cat No. 4200 97 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCCB, 4 Pole, 125 Amps rating, rupturing capacity 36 kA, 415 Volt grade, AC, 50 Hz, with adjustable Thermal Magnetic Protection complete all as directed. Make :- Legrand Cat No. 4200 96 or equivalent in makes mentioned in Appendix 'B' here-in-after.
S&F in repairs MCB SP 6 to 32 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
S&F in repairs MCB TP 63 Amp, 415 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
S&F in repairs MCB SPN 40 Amp, 240 V, 50 Hz, AC supply, 10 kA, 'C' Curve, complete all as directed.
M&L for sub main wiring with two runs of 6 sqmm (nominal area) size main cable & one run of 6 sqmm size earth continuity conductor, single core, PVC insulated, unsheathed, FRLS with multi-stranded copper conductor, 1100 Volts grade cables (ISI marked), drawn through & including suitable size of heavy duty non-metallic rigid PVC concealed conduit (ISI marked) not less than 25mm dia & conduit fittings/accessories, fixed concealed in wall/ceiling complete including dismantling & taking down old unserviceable sub main wiring. Notes :- (i) 02 runs of 6 sqmm size main cable, 01 run of 6 sqmm size earth continuity conductor cable & conduit with accessories shall be measured as one run length for payment purpose. (ii) Cost of cutting/leaving forming chases for conduits and making good in CM 1:4 shall deemed to be included in quoted rate of this item.
Supply, laying, jointing and testing LT XLPE insulated screened, bedded, galvanised steel strip or wire armoured heavy duty electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 50 sqmm 3.5 core (ISI marked) laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified including dismantling & taking out old unserviceable cable. Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately.
All as per serial item No. 148 here-in-above, but cross-sectional area 35 Sqmm 3.5 Core.
All as per item serial No. 148 here-in-above, but cross-sectional area 25 Sqmm 3.5 Core.
Supply and laying/fixing 50 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
Supply and laying/fixing 32 mm bore high density polyethylene pipes (HDPE) of pressure rating 6 kgf/cm2 with all fittings, laid in trenches, under floors or roads/ along poles etc for protection of electric cables, fixed in repairs, complete all as directed.
M&L for Galvanized iron tubing, 100mm bore light grade, ISI marked, including all fittings and laid in trenches/under road/drains, fixed to poles/walls etc with required size of flat iron (minimum 25mmx3mm) clamps, bolts, nuts and washers for protection of LT electric cable including taking down old unserviceable protection pipe with clamps complete all as specified & as directed. Note :- Excavation & earthwork shall be measured & paid for separately.
M&L for earthing complete with galvanized steel earth plate as electrode 600x600x6 mm buried directly in ground vertically to a depth not less than 2.25 m below ground level with top edge of earth plate at a depth not less than 1.5 m below ground level connected using galvanized iron earth lead wire 4 mm dia upto 7.5mtr as earthing lead by means of bolts, nuts, check nuts and washers of GI earth lead wire protected by Gl light grade pipe 15 mm bore, including provision of concrete pit of PCC 1:2:4, type B1 (using 20 mm graded stone aggregate) with 40 mm thick cover of RCC 1:2:4 reinforced with 8 mm dia TMT bars reinforced at 100 mm C/C both ways and handle of 6 mm dia MS bar made to shape, GI light grade 20 mm bore pipe for watering perforated at bottom, 2 m long placed on top edge of earth plate, charcoal and common salt filling test point made out of 40x8 mm flange with fixing arrangement, funnel, wire mesh and earth work in any type of soil, returning, filling in and removal of surplus soil to a distance not exceeding 50 m all as per electrical Plate No. 3 of SSR Part I and connected to earth test point including testing on completion complete all as specified & as directed including dismantling & taking out old existing unserviceable earthing.
M&L for cutting of existing road/ PCC floor/ Interlocking tiles for removing / laying UG Cables/ pipe line, depth of cutting not exceeding 60cm and width 45cm and filling the trench of road i.e. excluding top 15cm with existing aggregate obtained from cutting, watered and properly rammed to satisfaction of EIC and finally provide with & including 15 cm thick PCC 1:2:4 type B1 using 20 mm graded crushed stone aggregate to entire width of trench including re-setting of interlocking tiles & finally match the top surface to road & disposal of debris to a distance not exceeding 250 metre and depositing where directed complete all as directed.
S&F in repairs mounting bracket (suitable for fixing/holding street/security light fittings) made of 32mm bore GI pipe ‘light grade’ not less than 1.20m long, bent to shape at required angle, fixed to Pole/wall with & including mild steel clamps (02 Nos) made out of flat iron 50x6mm with nuts, bolts & washers, matching with section of Pole/suitable for wall, complete all as specified and as directed.
S t modi
M/S JAYCONSTRUCTION CO
JAMNAGAR ELECTRIC AND MACHINERY CO
IDEAL CONSTRUCTION COMPANY
AARTI ENTERPRISE
KEVAL ENTERPRISE
Sagar Builders
M/s.Bhavin Electricals
Amar Constructions
M/s. Jayant G Rampariya
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .