AGM P and P
ASSISTANT GENERAL MANAGER PROJECTS AND PLANNING PD ADMINISTRATION
INTERNAL ELECTRIFICATION WORKS OF S3 QUARTERS AT UDL TOWNSHIP 2026
2026_FACT_906780_1
3017/2026-2027/E33450
Open Tender
Miscellaneous Works
Item Rate
122 days
UDYOGAMANDAL
ATTACHED IN TERMS AND CONDITIONS
6 documents required · 6 mandatory
₹0
₹5,000
Yes
21 May 2026
29 Apr 2026
21 May 2026
29 Apr 2026
20 May 2026
29 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1INTERNAL ELECTRIFICATION WORKS OF S3 QUARTERS AT UDL TOWNSHIP-2026 | |||||
| 1.01 | Supply, Erection,Termination and connection of the 6 way, 3ph, 415V Horizontal double door MCB DB Having following specification for lighting circuits:
1) 63 A, 4 pole Isolator-1 No.
2) 63 A 4 pole RCCB with 30 mA sensitivity -1 No.
2) 6 A SP MCB B type - 5 Nos.
3) 10 A SP MCB B type -4 Nos.
4) 16 A SP MCB C type- 3 Nos
DB shall be properly flush mounted by the contractor.All Required items for this Work Shall Be in the scope of the Contractor Including the proper plastering /cementing and finishing of the wall after fixing of the DB. Unused space shall be covered by dummy plates in DB.
***For acceptable makes you may refer ST&C. | 1 | NO | - | - |
| 1.02 | Supply, Erection, Termination and connection of the 8 way, three phase, 415 V Horizontal double door MCB DB having following specification for power circuits:
1) 63 A, 4 pole Isolator-1 No.
2) 63 A 4 pole RCCB with 30 mA sensitivity -1 No.
2) 20 A DP MCB C type - 6 Nos.
3) 25 A DP MCB C type -4 Nos.
DB shall be properly flush mounted by the contractor by the contractor. All Required items for this Work Shall Be in the scope of the Contractor Including proper plastering /cementing and finishing of the wall after fixing of the DB. Unused space shall be covered by dummy plates.
***For acceptable makes you may refer ST&C. | 1 | NO | - | - |
| 1.03 | PVC conduit point wiring over/through beam/wall/column/ceiling with individual control for light /fan /bell/ 6A modular plug sockets separately mounted using FRLS flexible copper wires of 1.5 sq.mm for phase, neutral and earth connection through PVC conduit of minimum size of 20mm with ISI marking, as per relevant drawings or instructions from FACT engineer. Scope of work include preparation and fixing of PVC conduits, modular switch boards, switches, cover plates,dummy plates etc, fixing ceiling roses on suitable junction boxes, modular step type regulators for fans(as required), drawing flexible copper wires of 1.5 sq.mm, connecting, testing and commissioning.The PVC conduit fixing shall be concealed.The contractor shall carry out the cutting of walls as required and ensure proper replastering after work, restoring aesthetic appearance. All the switch boards must be fixed concealed, unless asked to fix on surface. If required, holes through wall need to be made for conduit passing. For a point wiring, pipe length of 10 metres shall be considered as one point and pipe length above 10m shall be considered as one and half points and if additional power sockets are provided in same switch boards that shall be considered as half point. Sockets shall be shutter type. All the materials required for wiring such as copper flexible wires, PVC conduits, modular switch boards, modular switches, cover plate, dummy plates, PVC box for fixing ceiling rose, PVC Junction boxes (2/3/4 way) etc. shall be in the scope of contractor.The contractor can use 25 mm ISI marked conduit pipe, if required for routing and drawing of cables after consulting the Engineer in charge. The contractor shall draw 2.5 sq.mm FRLS copper flexible cable for phase and neutral conductors, and 1.5 sq.mm FRLS copper cable for earth connection from the DB to the respective switchboards, complete with necessary terminations.
***For acceptable makes you may refer ST&C. | 140 | NO | - | - |
| 1.04 | PVC conduit Point wiring over/through beam/ wall/column / ceiling with individual control for 16 A modular plug sockets with SP switch. Individual plug socket with switch. Wiring shall be using 2.5 sq.mm FRLS multi strand flexible copper wire for phase, neutral and earth connections, through PVC conduits of minimum size 20 mm with ISI mark. The work shall include preparation and fixing of PVC conduits, wiring along wall and drawing wires as required,preparation and fixing of modular switch boards, switches, plug sockets, cover plates, dummy plates, suitable junction boxes etc., wire termination, testing and commissioning. Sockets shall be 6/16A type. The PVC conduit fixing shall be concealed. The contractor shall carry out the cutting of walls as required and ensure proper replastering after work, restoring aesthetic appearance. All the switch boards must be fixed concealed, unless asked to fix on surface. If required, holes through wall need to be made for conduit passing.For a point wiring, 10 metres shall be considered as one point and Pipe length above 10m shall m shall be considered as one and half points and if additional power sockets are provided in same switch boards that shall be considered as half point.The contractor shall draw 2.5 sq.mm FRLS copper flexible cable for phase and neutral conductors, and 1.5 sq.mm FRLS copper cable for earth connection from the DB to the respective switchboards, complete with necessary terminations.
***For acceptable makes you may refer ST&C. | 45 | NO | - | - |
| 1.05 | PVC conduit Point wiring over/through beam/wall / column / ceiling with individual control for 25 A modular plug socket for Air conditioners/ geyser by using 25A DP modular switch. Individual plug socket shall be placed near Air Conditioner/ Geyser point and switch shall be at standard height from ground. Wiring shall be using 4 sq.mm FRLS multi strand flexible copper wire for phase, neutral and earth connections, through PVC conduit of minimum size of 20mm with ISI marking. The work shall include preparation and fixing of conduits and drawing wires through 20mm PVC pipe from DB to modular switch and to socket as required, preparation and fixing of modular switch boards, switches, plug sockets, cover plates, dummy plates, suitable junction boxes etc., wire termination, testing and commissioning. The PVC conduit fixing shall either be concealed. The contractor shall carry out the cutting of walls as required and ensure proper replastering after work, restoring aesthetic appearance. All the switch boards must be fixed concealed, unless asked to fix on surface.For a point wiring, 10 metres shall be considered as one point and Pipe length above 10m shall be considered as one and half points. All the materials for this Work including PVC conduits, copper flexible wires, 25 A Plug socket, 25 A DP switch etc. shall be in the Scope of the contractor.
***For acceptable makes you may refer ST&C. | 17 | NO | - | - |
| 1.06 | Supply, Installation, Testing and Commissioning of 1200 mm sweep, BEE star rated, ceiling fan with BLDC Motor, 3 nos. blades,down rod,canopies, shackle kit,copper winding,Service Value (CM/M/W) minimum 5.5, Air delivery minimum 210 Cum/Min , electronic regulator unit for speed control and all remaining accessories including safety pin, nut bolts, washers,suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. complete as required.
***For acceptable makes you may refer ST&C. | 8 | NO | - | - |
| 1.07 | Supply and Installation of 20 W LED tube fittings with required clamps/fastners. All materials such as LED Fittings, clamps and fastners required for this work are in the scope of the contractor.
***For acceptable makes you may refer ST&C. | 40 | NO | - | - |
| 1.08 | Supply and fixing of Calling Bell/Buzzer suitable for single phase 230 V complete as required. All materials such as Calling Bell of reputed make, clamps and fastners required for this work are in the scope of the contractor.
***For acceptable makes you may refer ST&C. | 1 | NO | - | - |
| 1.09 | Supply and Installation of 15 W LED Bulb fittings with required angle holders. All materials such as LED bulb,holders required for this work are in the scope of the contractor.
***For acceptable makes you may refer ST&C. | 10 | NO | - | - |
stage.html
html • 0.02 MB
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.12 MB
STC33450.pdf
Tender Documents • 14.65 MB
BOQ_953107.xls
BOQ • 0.28 MB
comp33450.pdf
Additional Documents • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .