Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹68.8 LAccepted-AOC | ₹68.8 L | L1 | Accepted-AOC AOC |
| 2 | L2₹73.5 LRejected-Finance | ₹73.5 L | L2 | Rejected-Finance Highest Rate Quoted by bidder |
| 3 | Not Admitted-Fee/PreQual/Technical/Finance 8 0 241 | SOUTH EAST | DELHI | 110003 | - | - | Not Admitted-Fee/PreQual/Technical/Finance Not qualified for AOC |
Tender Value
₹75 L
EMD Value
₹1.5 L
Closing Date
14 May 2018, 3:00 pmClosed
PROJECT MANAGER
OFFICE OF THE PROJECT MANAGER CONSTRUCTION UNIT UTTARAKHAND PEYJAL NIGAM CHAMBA
CONSTRUCTION OF STATE AYURVEDIC DISPENSERY AT BHANGLA BLOCK NARENDRA NAGAR DISTT TEHRI GARHWAL
2018_MDPEY_10825_1
LetterNo 242/817/07 Dated 21.04.2018
Open Tender
Civil Works
365 days
BHANGLA BLOCK NARENDRA NAGAR DISTT TEHRI
Please refer Tender documents.
3 documents required · 3 mandatory
₹2,360
PROJECT MANAGER CONSTRUCTION UNIT UKPJN
₹1.5 L
Chamba
11 Dec 2025
28 Apr 2018
16 May 2018
30 Apr 2018
14 May 2018
9 May 2018
30 Apr 2018
Amount
ABSTRACT OF COST
Earth work in excavation in foundation trenches or drains (exceeding 1.5m in width or 10 sqm on plan) including dressing 0 sides and ramming of bottoms, lift up to 1.5 including getting out the excavated soil as directed. All kinds of soil
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering all workup to plinth level mix 1:4:8 (1 cement 4 coarsee sand, 40mm nominal size)
Supplying and filling in plinth with jamuna sand under floor including watering, consolidating and dressing complete.
Diluting and injecting chemical emulstion for pre constructional anti termite treatment in foundation trenches and under floor (before and after earth filing) so as to create a chemical barrier the chemical shall be "DURSBAN" and used in recommended proportion the plinth area of the building shall be measured for payment.
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 concrete sand : 6 graded aggregate 20mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smoothes.
Providing and laying damp-proof course 50mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand : 3 graded stone aggregate 20 mm nominal size) all work up to plinth level.
Providing and supplying bitumen painting at plinth level complete all works.
Providing and laying 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20mm nominal size) all work up to plinth level.
Reinforcement cement concrete work 1:1.5:3 in (1 cement : 1.5 coarse : 3 graded stone aggregate 20 mm nominal size) walls, plinth and string courses, columns, pillars, lintels, beams, suspended floor, landing, etc. above plinth level (excluding cost of centering, shuttering, and reinforcement.
Providing and supplying water proofing compounds in RCC Qty
Centering and shuttering including strutting prepping etc and removal of form for
Foundations, footing, bases of columns etc for mass concrete
Column
Beams
Slabs / Chajjas
Brick work in foundation of class designation 75 in cement mortar 1:6 91 cement : 6 corase sand)
Brick work in superstructure of class designation 75 in cement mortar 1:6 (1 cement : 6 coarse sand)
Half brick masonry with bricks of class designation 75 in super structure, above plinth up to floor two level in cement mortar 1:4 (1 cement : 4 coarse sand)
Providing and fixing L-angle iron frames with (40×40×6) mm size for those windows and ventilators joints with complete.
Providing and fixing 35 mm thick flush door shutter core of blocks board construction with frame of 1st class wood and well matched 1st class ply veneering with vertical grains or cross bands and face veneer on one face and commercial ply veneering with vertical grains or cross bands and face veneer on other face of shutters including nickel plated bright finished MS piano hinges with necessary scraws.
Providing and fixing factory made ISI marked steel glazed doors,windows and ventilators side /top /centre hung with beading and all members such as K11 B and K12 B etc. complete of standard rolled steel sections, joints mitred and flash butt welded and sash bars tenoned and riveted with 15x3mm lugs, 10cm long,embedded in cement concrete blocks 15x10x10cm of 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20mm nominal size) or with wooden plugs and screws or rawl plugs and screws or with fixing clips or with bolts and nuts as required, including providing and fixing of hinges,pivots, float glass panes with glazing clips and special metal sash putty of approved make and a priming coat of approved steel primer excluding the cost of metal beading and other fittings except necessary hinges or pivots complete as per approved design.
Providing and fixing mosquito fixed with MS flat and complete the work
Providing and fixing mild steel grills welded with MS flat and frames all work complete
Providing synthetic enamel paint on wood and steel work including the case of primer complete the work
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1: 4 (1 cement : 4 coarse sand) :
Providing and fixing 5 mm thick white glazed tiles on walls all the complete work (Floors + waklkl up to 2100 mm)
Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with grey cement slurry mixed with pigment to match the shade of the slabs, including rubbing and polishing complete.
15mm thick cement plaster rought side of brick work 1:6 cement mortar (1 cement : 5 corase sand) including scaffolding (inner plaster)
12mm thick cement plaster fair side of brick work 1:6 cement mortar (1 cement : 5 coarse sand) including scaffolding (Outer plaster)
6 mm thick cement plaster on ceiling & chajja 1:3 cement mortar (1 cement : 3 coarse sand) including scaffolding
Finishing walls with snowceam paints
Distempering with oil bound washable distemper of approved brand and manufactuer to give an even shade on new work two or more coats.
Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
Providing and laying clay tiles on roof jointed with cement mortar 1:4 (1 cement : 4 coarse sand) and finishing with neat complete
Providing and laying reinforcement including straightening cutting bending placing in position and binding all the work complete
ABSTRACT OF COST OF ELECTRICAL
WGPVCPT Point wiring in PVC conduit, with piano type switch: Wiring for light point/ fan point/ exhaust fan point/ recessed PVC conduit, with piano type switch, phenolic laminated sheet, suitable size M.S box and earthing the point with 1.5 sq. mm. FR PVC insulated copper conductor single core cable etc. as required.
Group B
WGSTLPTTC Twin Control point wiring in PVC conduit, with paino type switch: Wiring for twin control light point with 1.5 sq.mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, 2 way piano type switch, phenolic laminated sheet, suitable size Gl box and earthing the point with 1.5 sq.mm FR PVC insulated copper conductor single core cable etc. as required.
WGPVCPP2 Power plug wiring in PVC conduit (2x4 sq. mm): Wiring for light/ power plug with 2x4 sq. mm FR PVC insulated copper conductor single core cable in surface/ recessed PVC conduit alongwith 1 No 4 sq. mm FR PVC insulated copper conductor single core cable for loop earthing as required.
WGPVCSB Circuit/sub-man wiring in PVC conduit: Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of PVC insulated copper conductor, single core cable in surface/ recessed PVC conduit as required.
2 x 2.5 sq. mm + 1 x 2.5 sq. mm earth wire
LPACCPT S/F light plug point piano type accessories: Supplying and fixing metal box of 150mm x 75mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 3 pin 5/6 anos socket outlet and 5/6 amps piano type switch, connection, painting etc. as required. (For light plugs to be used in non residential buildings).
PPACCPT S/F power plug point plano type accessories: Supplying and fixing metal box of 180mm x 100mm x 60mm deep (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including providing and fixing 6 pin 5/6 & 15/16 amps socket outlet and 15/16 amps piano type switch, connection, painting etc. as required.
ITCFFSUR ITC fluorescent fitting directly on surface: Installation, testing and commissioning of pre-wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling / wall, including connection with 1.5 sq.mm FR PVC insulated, copper conductor, single core cable and earthing etc. as required.
ITCCFFC ITC ceiling fan with cover on fan box: Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq, mm FR PVC insulated, copper conductor, single core cable, including providing and fixing phenolic laminated sheet cover on the fan box etc. as required.
ITCER S/F resistance type ceiling fan regulator: Insallation, testing and commissioning of resistance type ceiling fan regulator, in existing switch box including connection with 1.5 sq. mm FR PVC insulated, copper conductor,single core cable. earthing the regulator etc. as required.
SPMCBDB S/F SP MCB DB: Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess, complete with tinned copper busbar, neutral busbar, earth bar, din bar, detachable gland plate, interconnectios, phosphatized and powder painted including earthing etc. as required. (But without MCB/RCCB/lsolator)
8 way Single door
MCBC S/F 'C' series, SP MCB Supplying and fixing 5 amps to 32 amps rating, 240 volts, 'C' series, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.
Single pole and neutral
Supply of ceiling fans 1200 mm
Supply of regulators
Supply of florocent tube lights 1200 mm
ABSTRACT OF COST OF WATER SUPPLY & SANITATION WORKS
(a) W.C. Pan
(b) Urinal Pan
Wash Basin
PVC Flush Cistern
P/F of Sink
P/F of 100 CI / PVC
P/F of 20mm dia G.I. Pipe
P/F of 15mm dia G.I. Pipe
Bib Cock 15 mm
Stop Cock 15 mm
Water Tank 100o ltr
ABSTRACT OF COST OF DRAINAGE
Providing, laying and jointing glazed stoneware pipes grade ‘A’ with stiff mixture
100 mm diameter
Providing and laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40 mm nominal size) all round S.W pipe including bed concrete as per standard design:
100x100 mm size P type
Providing and fixing square-mouth S.W. gully trap grade ‘A” complete with C.I.
With F.P.S Brick class designation 75
Constructing brick masonry manhole in cement mortar 1:4 ( 1 cement : 4 coarse sand) Inside size 90x80 cm and .45 cm deep including C.I. cover with frame (light duty) 455x610 mm internal dimensions total weight of cover and frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg)
With F.P.S. bricks with class designation 75
Extra depth for manholes
Size 90x80 cm
With F.P.S brick class designation 75
ABSTRACT OF COST (SEPTIC TANK & SOAK PIT)
Excavation in foundation :in ordinary soil including lift up to 1.5 meter (5ft) and lead up to 30 meters (100ft) and including filling , watering and ramming of excavated earth into the the trenches or into the space between the building and the sides of foundatin trenches or into the plinth and removal and disposal of surplus earth as directed by the engineer-in-charge trenches including cost of labour T&P complete.
All kinds of soil.
Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30cm in depth. 1.5m in width as well as 10 sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m, for plinth filling including watering remaning and drassing complete.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated Bars.
Centring and shuttering including strutting,ropping etc. and removal of form for
Suspended floors, roofs, landings, balconies and access platform.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in
Cement mortar 1:6 (1 cement : 6 coarse sand)
Honey-comb brick work 10/11.4 cm thick with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand).
S/Filling brick ballast 50 mm size
12 mm cement plaster finished with a floating coat of neat cement of mix
1:3 (1 cement : 3 fine sand)
Cement concrete flooring 1:2:4 (1 cement: 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry, but excluding the cost of nosing of steps etc. complete.
40mm thick with 20mm nominal size stone aggregate.
Manhole cover
Inlet Pipe 100 mm dia
Outlet Pipe 100 mm dia
ABSTRACT OF COST OF RAIN WATER HARVESTING
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
All kinds of soil.
Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and lift upto 1.5 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size)
1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level
1:2:4 (1 Cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size).
Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers,abutments, posts and struts etc. upto floor five level excluding cost of centring, shuttering, finishing and reinforcement
1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete. Thermo-Mechanically Treated Bars.
Centring and shuttering including strutting,ropping etc. and removal of form for
Suspended floors, roofs, landings, balconies and access platform.
Brick work with F.P.S. bricks of class designation 75 in foundation and plinth in
Cement mortar 1:6 (1 cement : 6 coarse sand)
Honey-comb brick work 10/11.4 cm thick with bricks of class designation 75 in cement mortar 1:4 (1 cement : 4 coarse sand). Rs. 277.2X2 For 23 cm thick wall
12 mm thick cement plaster in 1:4 ( 1 cement and 4 fine sand) mortar including supply of all material , labour and T&P etc. required for proper completion of the work.
1:4 (1 cement : 4 fine sand)
Inlet Pipe 100 mm dia
Outlet Pipe 100 mm dia
Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS :
110 MM Dia
Constructing masonry chamber 30x30x50 cm, inside with 75 class designation brick work in cement mortar 1:4 (1cement :4 coarse sand ) with C.c 1:2:4 floor over C.C 1:5:10 Finished with a floating coat of neat cement complete .
Supplying and fixing C.I. cover 300x300 mm without frame for gully trap (standard pattern) the weight of cover to be not less than 4.5kg
ABSTRACT OF COST OF PROTECTION WORK
Earth work in excavation by mechanical means (Hydraulic Excavator )/ manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan) including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level 1:4:8 (1 Cement : 4 coarse sand : 8 graded stone aggregate 40 mm nominal size).
Random rubble masonry with hard stone in foundation and plinth including levellingup with cement concrete 1:6:12 (1 cement: 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at plinth level with
Cement mortar 1:6 (1 cement : 6 coarse sand)
Extra for random rubble masonry with hard stone in superstructure above plinth level and upto floor five level, including leveling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20mm nominal size) at window sills, ceiling level and the like
Cement mortar 1:6 (1 cement : 6 coarse sand)
ABSTRACT OF COST OF EXTERNAL WATER SUPPLY
Connection charges of external W/S paid to Uttarakhand Jal Sansthan.
Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. (external work)
25 mm dia nominal bore
ABSTRACT OF COST OF EXTERNAL ELECTRIFICATION
Connection charges and work of external electrification paid to Uttarakhand Power Corporation.
Sumer Bhatt
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_13428.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid