| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹16.7 LAccepted-AOC NO 2254 RAGHAVENDRA COLONY SHAKTINAGAR RAICHUR RAICHUR KARNATAKA 584170 | RAICHUR | KARNATAKA | 584170 | L1 | Accepted-AOC As L1 bidder | |
| 2 | L2₹18.9 L+₹2.2 L (13.1%)Rejected-AOC | L2 | Rejected-AOC As L2 bidder |
Tender Value
₹20.7 L
EMD Value
₹41,500
Closing Date
27 Jun 2022, 12:00 pmClosed
GM, BTPS
Administrative Building, Bandel Thermal Power Station, Tribeni, Dist Hooghly Pin712503
ARC for maintenance of Boiler Pressure Parts of Stage-I and Stage-II BTPS under
2022_WBPDC_382923_1
WBPDCL/BTPS/NIT/E2050/22-23
Open Tender
Support/Maintenance Service
Item Rate
365 days
Bandel Thermal Power Station
Please refer Tender documents.
7 documents required · 7 mandatory
₹0
₹41,500
Bandel Thermal Power Station, Hooghly
13 Oct 2022
3 Jun 2022
29 Jun 2022
3 Jun 2022
27 Jun 2022
13 Jun 2022
10 Jun 2022
Amount
Maintenance of Boiler pressure part Stage-1
ECONOMISER TUBE JOINT Tube OD 51 mm, Thickness 4.8 mm, Material: SA 210 GR.C or equivalent
INSERT AT FURNACE WALL, GOOSE NECK S-PANNEL & ROOF TUBE (1 insert = 02 nos. joint) Tube OD: 63.5 mm TO 69.9 mm, Thickness from 5.1 to 6.3 mm, Material: SA 210 GR. A or equivalent
JOINT AT SATURATED SCREEN ROOF & SIDE WALL, SCREEN TUBE, PRIMARY SUPERHEATER TUBE, SECONDARY SUPERHEATER TUBE. (OD: 63.5 mm, Thickness: 5 mm upto 6.9 mm, Material: SA213T11 OR EQUIVALNT)
JOINT AT REHEATER TUBE /INSERT AT FURNACE WALL, GOOSE NECK, S-PANEL & ROOF TUBE.
Second pass scaffolding
Economiser coil lifting repairing, fitting & jointing with proper alignment for unit 1 & 2 (if required for preventive checking beyond leakage area)
Primary & secondary superheater coil pulling, inspection and proper alignment of coil & panel with clit and support welding of unit 1 & 2 (if checking required for preventive inspection)
Maintenance of Boiler pressure part Stage-II
LP water Cleaning Economizer Zone, PSH & PRH
Joint for lnsertion of water wall tube, cage rear wall below main cavity & baffle wall tube below main cavity,Size: 63.5X5.4, Mat: BS3059/45S2 or 5A210Gr.C.
Insertion joint for division wall tube Size: 82.5X7, Mat: BS3059/45S2; or SA210Gr.C
Joint for lnsertion of furnace roof, cage rear wall & baffle wall tube above main cavity, Size: 63.5X4.8, Mat: BS3059/620S2 or SA213T11
Joint for Insertion of economiser tube Size: 38.1X3.6, Mat: BS3O59/45S2 or SA210Gr.C
Insertion joint of PSH bottom & middle Size:57.1X6, Mat: BS3059/620S2 or SA213T11
Joint for Insertion of PSH top bank tube tube, Size: 63.5X3.6, Mat: BS3059/33S2 orSA210Gr.C
Insertion joint of PRH bottom & middle Size: 57X3.2, Mat: BS3059/620S2 or SA213T11
Joint for lnsertion of PRH top bank tube Size: 57X3.2, Mat: BS3059/620S2 or SA213T11
Joint for lnsertion of PLSH and FSH inlet tube, Size: 44.5X7, Mat: SA213T22
Joint for lnsertion of FSH & FRH tube Size: 50.8X3.6, Mat: SA213T91
Economiser/PSH/PRH coil lifting, inspection repairing and fitting with proper alignment (if required for preventive inspection beyond the leakage area)
Platen SH, FSH, FRH coil pulling inspection and proper alignment of coil and panel with clit and support welding
Second pass scaffolding Per 6 Meter
Common work for Stage-I&II
Stress Relieving
Radiography
Removal and refitting of refractory
Replacement of high pressure valve size upto 2''
Replacement of high pressure line (1/2'' to 4'') (Unit of 01 "Number" includes two joints)
Deinsulation & insulation with cladding of wall, casing and pipe and other area of boiler
HP Valve Welding from 50 NB upto 100 NB pipe
HP valve gland packing replacement upto 6"
HP valve servicing including gland packing & bonnet seal replacement upto 4"
D-metering of boiler tube at any area of boiler for thickness measurement (minimum survey 150 nos./day)
Minimum mobilization charge if total executed job value less than Rs.15000.00
Vertical scaffolding for approaching Roof Tube/ Reheater/ Secondary SH (Per 6 Meter Vertical) for Stage I & for approaching Furnace/ Roof Tube/ Pendent Reheater/ Platen/FSH & Division wall (Per 6 Meter Vertical) for Stage II
Horizontal scaffolding for approaching Platen SH/SCW/ Roof Tubes/Furnace (Per 6 Meter horizontal) for Stage I & for approaching RH/ platen SH / Final SH / Divisional wall/SCW/ Roof Tubes/ Furnace (per 6 meter horizontal)for Stage II
Guard Tube and Guard Plate Removal, Fabrication and Fitting
Build up in eroded Tubes as per requirement
Repairing of skin casing
Fabrication of bends of any degree of any boiler tube
Fitting and welding of tube attachment wherever require
Membrane strip fitting & welding
Fabrication and erection of Steel items by MS plate/ MS Angle/ MS channel/ I Beam etc.
Boiler metal temp TC & mounting replace
Thermowell replacement in HP line
A. D. Enterprise
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .