Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹16.9 LAccepted-AOC NEW DELHI | NEW DELHI | DELHI | 110001 | 1 | Accepted-AOC L1 | |
| 2 | 2₹17.2 L+₹30,120 (1.78%)Rejected-Finance | 2 | Rejected-Finance L2 | |
| 3 | 3₹18.6 L+₹1.6 L (9.60%)Rejected-Finance N A | 3 | Rejected-Finance L3 | |
| 4 | 4₹20.4 L+₹3.5 L (20.4%)Rejected-Finance B 246 FARMER APPTT SEC 13 ROHINI DELHI 85 | 85 | 4 | Rejected-Finance L4 | |
| 5 | 5₹20.4 L+₹3.5 L (20.4%)Rejected-Finance H 50 C SHAKARPUR DELHI 110092 | SHAHDARA | DELHI | 110092 | 5 | Rejected-Finance L5 |
Tender Value
₹23.8 L
EMD Value
₹47,700
Closing Date
17 Aug 2023, 11:00 amClosed
EX. ENGINEER (ELECT)-IV/KBZ
OFFICE OF THE EX. ENGINEER (ELECT)-IV/KBZ TOURIST CAMP SITE, J.L.NEHRU MARG, DELHI-02
Installation of 60 Nos 5-mtr street light Poles near Ravidas Mandir,Between Liberty Gole Chakar to Ramjas Gole Chakar, Ramjas Road Park Block 60,61,53,54,52, Manakpura, Gaushala Road, Rathnam Nagar, Ahata Thakur Das, Sheedipura, Joshi Road, Faiz R
2023_MCD_164187_1
MCD/TR/1343/2023_6_1_1/1
Open Tender
Electrical Works
Item Rate
120 days
Karol Bagh
5 documents required · 5 mandatory
₹590
₹47,700
7 Oct 2023
11 Aug 2023
18 Aug 2023
11 Aug 2023
17 Aug 2023
11 Aug 2023
Amount
SR items
1.17.12:Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm
5.1:Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (but without charcoal/ coke and salt ) as required.
5.12:Providing and laying earth connection from earth electrode with 6 SWG dia G.I. Wire in 15 mm dia G.I. pipe from earth electrode including connection with G.I. thimble excavation and re-filling as required.
5.18:Providing and fixing 6 SWG dia G.I. wire on surface or in recess for loop earthing along with existing surface/ recessed conduit/ submain wiring/ cable as required.
7.5.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required.Upto 35 sq. mm
7.6.1:Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required.Upto 35 sq. mm
14.16.1.a:Supplying and laying of following size DWC HOPE pipe lSI marked along with all accessories like socket, bend, couplers etc. conforming to IS 14930, Part II complete with fitting and cutting, jointing etc.direct in ground (75 em below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. , complete as required.63 mm dia (OD-63 mm & ID-51 mm nominal)
OD1442/2023-2024:P&F name board made of MS Sheet 90x60 cm, 1mm thick with frame of MS angle 50x50x6mm, two diagonal braces at the back of the sheet of MS flat 40x6 mm, total height of the board above ground level 2.4 metre, length of legs below ground 0.3 m embedded in CC Block 1:2:4 ( 1 Cement: 2 Coarse sand : 4 Graded stone aggregate 20 mm nominal size ) 20x30x45 cm i/c excavation and removal of surplus earth with in 50 m lead, applying priming coat of approved steel primer, painting with synthetic enamel paint of approved quality and lettering with enamel paint of approved colour ( one side) as per drawing/direction of Engineer-in- Charge.
AR items
122.1.2:Supply of XLPE insulated PVC sheathed Al. Conductor Armoured Cable 1.1KV grade conforming to IS-7098 of following size:-2C*6 sqmm
122.2.7: Fabrication, supply & erection of following size flange mounted hot dip galvanized octagonal pole made from HT steel plate, window with flash cover with full vertical window cover at appropriate height from the base plate on existing cement concrete pedestal as required. i/c supplying and fixing of 6 mm thick laminated mounted sheet inside the window mounted on and i/c providing and welding 3 nos. GI strips 4 mm thick of suitable length and having suitable size tapped holes as reqd, terminal block suitable for 25 sq mm conductor - 4 nos. & shorting links on DIN channel i/cpdg and fixing DIN channel of suitable length,, 6 Amp. SPMCB 'C' characteristics, earth stud, cable support clamp suitable for upto 4x25 sqmm cable. Logo/Name of manufacturer shall be embossed on the pole. Galvanization as per relevant IS.5.0 mtr height, 3 mm thick, bottom dia of 130mm & top dia of 70mm base plate of size 225 x 225 x 12 mm thick
122.2.10:Providing and laying in position M25 grade reinforced cement concrete foundation of size 450 mm (L) ×450 mm wide and 1000 mm deep i/c excavation of earth, providing cutting, bending and placing in position, reinforcement of cold twisted bars of 12 mm dia- 960 mm long(approx)-8 nos. and reinforcement of cold twisted bars of 8 mm dia- 1400 mm (approx) -6 nos.(with 150 mm spacing) as required with supplying and positioning of 4 nos. foundation bolts 16 mm dia,600 mm long, J type i/c 2 nos. template anchor plates of size 225mm×225mm×3mm and providing DCW HDPE for cable entry and exit as required for 3 m and 5 mtr pole.
122.2.12:Fabrication, supplying and fixing class B galvanised single overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 40 mm dia galvanised pipe with tightening bolts complete as required.
122.2.34:SITC of 70/72W LED Street Light luminaire fitted with lens, top opening driver cover made of pressure die cast aluminium housing & toughened glass cover complete with the following specification as reqd with IP 66 protection (a) Total system wattage =70/72 watt +/- 5% (b) Luminaire Efficacy>=100 Lm/w (c) Power Factor>=0.95 (d) Protection Class- IP-66
122.2.18:Fabrication, supplying and fixing class B galvanised double overhang arm bracket made out of 250mm long galvanised top tube with cap and 1000mm long 40 mm dia galvanised pipes with tightening bolts complete as required.
Grover Electricals
CANTILEVER ENGINEERS
M/s Oberoi Electricals
Iluminators And Circuiteers
Bidder Name
Grover Electricals
Iluminators And Circuiteers
M/s. Nangal Electric Company
CANTILEVER ENGINEERS
M/s Oberoi Electricals
stage.html
html • 0.05 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .