| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹46.9 LAccepted-AOC | L-1 | Accepted-AOC Accepted | |
| 2 | L2₹56.2 L+₹7.7 L (15.8%)Rejected-AOC | L2 | Rejected-AOC Rejected | |
| 3 | L3₹57.6 L+₹9.0 L (18.6%)Rejected-AOC | L3 | Rejected-AOC Rejected | |
| 4 | L4₹57.9 L+₹9.4 L (19.3%)Rejected-AOC | L4 | Rejected-AOC Rejected | |
| 5 | L5₹58.0 L+₹9.5 L (19.6%)Rejected-AOC | L5 | Rejected-AOC Rejected |
Tender Value
Refer Docs
EMD Value
₹98,000
Closing Date
6 Jan 2021, 6:00 pmClosed
GE 969 EWS
GE 969 EWS c o 56 APO
PROVN OF 02X WC BLOCK, STORE AT COOK HOUSE AT MOHURA, TILING OF MEDICAL STORE AND ADS STORE OF BLDG NO T-30 AND T-32 AT FSC, STONE MASONRY RETAINING WALL AT BANDI
2020_MES_404674_1
CANO 969/WS- /2020-21
Open Tender
Civil Works
Item Rate
270 days
Rampur
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹98,000
Yes
15 Mar 2021
18 Dec 2020
8 Jan 2021
18 Dec 2020
6 Jan 2021
1 Jan 2021
Amount
Surface dressing n.exc 15 cm deep in hard/ dense soil. Complete all as specified and directed by Eng-In-Charge.
Excavation in trenches, not exceeding 1.5 M wide and not exceeding 1.5 M depth for foundation, shaft,wells, cesspits, manholes,laying cables etc., and getting out in Hard/Dense or any type of soil. Complete all as specified and directed by Eng-In-Charge.
Excavation in trenches, not exceeding 1.5 M width and exc 1.5m depth but not exceeding 3.0 M depth for foundation, etc., and getting out in Hard/Dense soil.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm thick with soils or hard/Dense soil.
Removing Excavated soils n.exc. 50m and depositing where directed at a level n.exc. 1.5m above the starting point.
M&L for plain Cement Concrete Type D2 1:4:8 (using 40 mm graded stone aggregate) in foundations, filling and mass concrete.
M&L for cement concrete (1:3:6) type C-2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete. Complete all as specified and directed by Eng-In-Charge.
M&L for cement concrete (1:2:4) type B2 using 40 mm graded stone aggregates as in foundation, filling and mass concrete. Complete all as specified and directed by Eng-In-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6. Complete all as specified and directed by Eng-In-Charge.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:6 but except stones.
M&L for walling of random rubble, uncoursed, well bonded, bedded and solidly hearted, built in cement mortar 1:4. Complete all as specified and directed by Eng-In-Charge.
M&L for walling of random rubble uncoursed, well bonded, bedded and solidly hearted, built in dry. Complete all as specified and directed by Eng-In-Charge.
M & L for precast cement Concrete 1:3:6 type C-1 Using 20mm graded crushed stone aggregates as in bond stones and set in CM 1 :4. Complete all as specified and directed by Eng-In-Charge.
M&L for PCC 1:2:4 type B-1(Using 20mm graded crushed stone aggregates ) as in coping and the like including slightly rounded/chamfered angle with and including necessary use and waste of form work for fair faces of concrete. Complete all as specified and directed by Eng-In-Charge.
M&L for raised pointing to random rubble masonry, uncoursed or brought up to courses in CM 1:4 Complete all as specified and directed by Eng-In-Charge.
M & L for broken stones / boulders loose filling withaggregates of gauge 40 to 80 mmin back of walls. Complete all as specified and directed by Eng-In-Charge.
Extra over RR stone masonry for hammer dressing to a face stones and dressing of face beds and joints as specified of randomrubble uncoursed or brought up to coarse max depression onface from straight edge held against the dressed sutface n'exc 40 mm .
M&L for damp proof course to horizontal or vertical surface including necessary form work 40 mm thick in Cement concrete 1:2:4 type B-0 using 12.5 mm graded stone aggregatge. Complete all as specified and directed by Eng-In-Charge.
M&L for brick work with sub-class `B' bricks, straight or curved on plan exceeding 6 M mean radius built in cement mortar 1:6. Complete all as specified and directed by Eng-In-Charge.
M&L brick work with sub class 'B' bricks straight or curved on plan to any radius in half brick thick wall built in cement mortar 1:4. Complete all as specified and directed by Eng-In-Charge.
M&L for rendering 15 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 and finished even and smooth without using extra cement.
M&L for rendering 15 mm thick on stone masonry surfaces other than fair faces of brick work in cement mortar 1:6
M&L for rendering 15mm thick on stone masonry surfaces or other than fair faces of brick work in CM 1:4. Complete all as specified and directed by Eng-In-Charge.
M&L for preparing newly plastered surfaces of walls and applying three coats of white wash.
M&L for preparing new plastered surfaces and applying Two coats of cement base paint on surfaces of walls.
M&L for preparing newly plastered surfaces of walls and applying two coats distember oil emulsion white or tinted. Complete all as specified and directed by Eng-In-Charge.
M&L for providing precast cement concrete Type B-1, 1:2:4 (20mm graged crushed stone aggregate) as in window or door cills, lintels bressumers, steps, quoin blocks, coping , kneerlers, apex stones, poier caps, columns, posts, bountry pillars, bd plates, pintle including chamfers , weatherings, throating etc and setting in mortar complete with joints to match all as specified set in cement mortar 1:6. Complete all as specified and directed by Eng-In-Charge.
Dismantling plain or corrugated steel sheeting any gauge thickness, including nanital or similar pattern roof covering.
S&F 0.63mm thick galvanised corrugated mild steel sheeting with two corrugation side lap fixed with coach screws and washers in roofs, walls etc with grage of zinc coating 275. Complete all as specified and directed by Eng-In-Charge.
All as item no. 29 above but except sheeting.
S&F 0.80 mm thick plain, galvanized, mild steel sheeting with grade of zinc coating 275, in ridges, hips, valley gutters, drip and straight flashings (Length and girth as fixed). Complete all as specified and directed by Eng-In-Charge.
S & F Rolled Mild steel Channels,angles,or tee sections fixed indipendently,with out connecting plates of Fe 410-W(Gde-E-250) quality -A. Complete all as specified and directed by Eng-In-Charge.
S&F Rolled mild steel sections in Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc of GE 410 (Gde-E-250 quality-A)
Dismantling of timber scantling 40 Sqcms and over in section in any position in unframed work.
M&L for second class soft wood clean sawn timber framed and fixed in scantling . Complete all as specified and directed by Eng-In-Charge.
All as per item no-35 above, but except timber.
Dismantling of timber scantling as in fillets, post, rafters, purlins etc, under 40 Sqcms in section in any position unframed work.
M&L for plain fillets, square rectangular or triangular in section clean sawn secured with nails or brads area exc 3 & n.exc 6 Sqm cm.
M&L for plain fillets, square rectangular or triangular in section clean sawn secured with nails or brads area exc 13 & n.exc 25 Sqm cm.
Dismantling wall and ceilling boards (fibre, pulp, insulation, etc) or insulation boards/slabs/blankets, any thickness, including cover fillets etc. Complete all as specified and directed by Eng-In-Charge.
M&L for 6mm thick ply wood grading BWR type BB with fixed with nails to timber frame work in wall . Complete all as specified and directed by Eng-In-Charge.
M & L 6 mm thick Ply wood, grade BWR, type BB fixed with nails to timber frame work in ceiling. Complete all as specified and directed by Eng-In-Charge.
Demolition of cement concrete (unreinforced) in ground floors and pavings n-exc 15cm thickness (below or above ground level).
M&L for plain cement concrete 1:4:8 type D-2 using 40mm graded crushed stone aggregate as in sub base for flooring 75 mm thick and finishing the concrete surfaces even and rough to receive topping layer .
M&L for 75 mm thick cement concrete 1:3:6 type C-2 using 40 mm graded stone aggregate in sub base. Complete all as specified and directed by Eng-In-Charge.
M&L for hard core of broken stone or boulder of gauge n. exceeding 63mm deposited, spread and levelled in layers not exceeding 15 cm thick, watered and rammed to a true surface.
M&L 75 mm thick cement concrete type C-2, 1:3:6 (using 40mm graded aggregate ) as in plinth protection/ Paving finishing cement concrete surface even and smooth without using extra cement. Complete all as specified and directed by Eng-In-Charge.
S&F vitrified Tiles 10 mm thick(square/ rectangular) polished,area of each tile n. exc. 0.36 sqm in floors etc,set & jointed in neat cement slurry and pointed in white or coloured cement to match incl screed bed or bedding layer of cement mortar 1:6, 15 mm thick for laying floor finishes .
S&F Coloured non skid ceramic tiles 300 x 300 x 7 mm thick, in floors etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match incl 15 mm thick screed bedding in CM 1:6. Complete all as specified and directed by Eng-In-Charge.
S&F Glazed ceramic tiles 350x250x 7mm/450x350x7 mm thick, in dado/Skirtings etc., set and jointed in neat cement slurry and pointed in white or Coloured cement to match incl rendering 10 mm thick on fair faces of brick work or concrete surfaces in cement mortar 1:4 for backing of Dado/ Skirting.
S&F Vitreous china sqatting pan 'Orrisa' pattern 580x440 mm white, with integral foot rest (excluding flushing cistern and flush pipe). Complete all as specified and directed by Eng-In-Charge.
S&F padestal pan ,trap , seat and cover including connection to drain pipe and to flushing pipe, antisyphonage pipe etc complete. Complete all as specified and directed by Eng-In-Charge.
S & F Vitreous China Wash Wash hand basin Pedestal type white, flat back, size 630 x 450 mm size (flat back or angle back type) including cutting for and pinning ends of brackets or erecting stand fixed in repair .
S&F PVC valveless,10 liters syphonic action cistern, low level, white, with inlet, ball valve, float and including brakets and connection to pipes. Complete all as specified and directed by Eng-In-Charge.
S&F 15mm bore Bib taps, cast copper alloy, with crutch or butterfly handle screwed down, screwed for iron or brass ferrule and fixed but fency type.
S&F 15 mm dia pillar tap fancy type with capstan heads CP screwed down high pressure with or with out lettered 'Hot' or 'Cold' with long screw shank fly nuts screwed shanks and fly-nuts screwed for iron pipe and fixed.
S&F PVC connections 15 MM size with PTMT nuts of length 450 mm flexible (ISI marked). Complete all as specified and directed by Eng-In-Charge.
S&F PVC connections 15 MM size with PTMT nuts of length 600mm. Complete all as specified and directed by Eng-In-Charge.
S&F 2nd class softwood 35mm thick plain,framed,pannelled shutters(any number of pannel),with panels of timber flat on both sides (feather edged),or of veneered particle board medium density, wood particle board with commercial face venner; supplied and fitted to chowkats, Complete all as specified and directed by Eng-In-Charge.
S/F 35mm thick 2nd class soft wood glazed & skeleton shutter open rebated and prepared to receive glass or wire mesh gange etc( without sash bars) edges of framings plain, chamfered or rounded, fitted with cut and mitred beads for securiny glass etc size of members of shutters as spd in SSR Part-I section 8 clause 8.24(a) Complete all as specified and directed by Eng-In-Charge.
S/F 30mm thick 2nd class soft wood glazed & skeleton window shutter open rebated and prepared to receive glass or wire mesh gange etc( without sash bars) edges of framings plain, chamfered or rounded, fitted with cut and mitred beads for securiny glass etc size of members of shutters as spd in SSR Part-I section 8 clause 8.24(b) Complete all as specified and directed by Eng-In-Charge.
S & F galvanised mild steel wire cloth 0.56 mm dia of wire and average width of aperture 1.18mm and fixed with tinned tacks or galvanised wire staples. Complete all as specified and directed by Eng-In-Charge.
S & F 4 mm thick Sheet glass, ordinary quality and glazing with oil putty in squares not exceeding 0.5 Sqm in each pane. Complete all as specified and directed by Eng-In-Charge.
S&F 150 mm long MS barrel tower bolts stove enameled black with bright bolt
S&F 100 mm long MS barrel tower bolts stove enameled black with bright bolt
S&F 200mm long MS sliding door bolt with haps, staple (bolt type)and fixing clips of sheet,and fixing bolts and sliding bolts of stove enameled black including necessary nut and bolts.
S&F 100mm long medium weight, cold rolled mild steel Butt hinges.
S&F 75mm long medium weight, cold rolled mild steel Butt hinges.
S&F 150 mm long MS pressed handle ovel type, stove enamelled Black
S&F 100 mm long MS pressed handle ovel type, stove enamelled Black
S&F Aluminum, anodized, barrel tower bolts of extruded section and fixed of length 150mm
S&F Aluminum, anodized, barrel tower bolts of extruded section and fixed of length 100 mm
S&F Aluminum anodized sliding door bolt with hasp and staples (bolt type)and fixing clips alloy and fixed of length 250 mm.
S&F Aluminum anodized sliding door bolt with hasp and staples (bolt type)and fixing clips alloy and fixed of length 300 mm.
S&F Aluminum anodized handles cast type of 150 mm.
S&F Aluminum anodized handles cast type of 100 mm.
S&F 15 mm bore tube medium grade galvanised with all fitting and fixed complete to walls and ceiling or laid in floors. Complete all as specified and directed by Eng-In-Charge.
S&F 15 mm bore stop valve cast copper alloy/ concealed type, screwed down with high pressure, with crutch or butterfly handle, screwed both ends for iron pipe or for unions for sizes.
S&F 15mm dia angle stope valve of PTMT any colour high pressure screwed for for iron pipe and fixed.
S&F 32mm waste coupling of PTMT. Complete all as specified and directed by Eng-In-Charge.
S&F 75 mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall.
S&F 110 mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, fixed to wall.
S&F Rotational moulded polyethylene water storage tanks, triple layers (cylindrical vertical with closed top) hoisted and fixed in position of 500 litres capacity all as specified in SSR Part I and directed by EIC.
S&F Rotational moulded polyethylene water storage tanks, triple layers (cylindrical vertical with closed top) hoisted and fixed in position of 1000 litres capacity all as specified in SSR Part I and directed by EIC.
S&F Framed brackets of angles or tees with web and flanges cut to shape, drilled and countersunk for screw, including bending and welding angles, as necessary, gusset plates, riveting, etc.. n exc 10 kg each brackets, conforming to Fe.290.Gde-E-165.
S&F 1.00mm thick Mild steel, plain, black sheet in wall cladding,steel gates and similar work, cut to size, holespunched; including round headed screws,clout nails or rivets and fixed to wood or steel framing with plain 40 mm lap joints with riveted or welded seams, including bending or turning up, mitred angles etc as required.
M&L for RCC 1:2:4 type B1 using 20 mm graded stone aggregate as in man hole cover slab. Complete all as specified and directed by Eng-In-Charge.
M&L for mild steel TMT Bars 10mm dia and over, quality, cut to length, bent to shape required including cranking, bending and binding with mild steel wire (annealed) not less than 0.9 mm dia
M&L for mild steel TMT bars 6 to 8 mm dia cut to length, bent to shape required including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9 mm dia.
All as per item No 89 above but 5 mm dia and over upto and including 10 mm dia in stirrups, spacers and binders.
S&F 110 mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors or weep holes.
S&F 75 mm bore pipe PVC (SWR) pipes single socketed, in any length with rubber ring joints, laid in trenches or in floors
S&F 110mm bore PVC (SWR) bends any radius with providing acceess door
S&F 75mm bore PVC (SWR) bends any radius with providing acceess door
S&F PVC (SWR) reducers 110mm bore. Complete all as specified and directed by Eng-In-Charge.
S& F (SWR) floor trap, 75mm diameter of outlet with grating including jointing with solvent cement. Complete all as specified and directed by Eng-In-Charge.
M&L for roughening surfaces of old concrete by picking,sweeping clean and washing down with water to remove dust etc. and Brushing with neat cement slurry @ 3.0 kg of cement per sqm. Complete all as specified and directed by Eng-In-Charge.
M&L for PCC 1:2:4 type B-1 (20mm graded aggregate) as in floor 25 mm thick. Complete all as specified and directed by Eng-In-Charge.
M&L for preparation of new wooden surfaces , not otherwise described over 10 cm width or grith and applying two coat of synthetic enamel paint over one coat pink primer. Complete all as specified and directed by Eng-In-Charge.
M&L for preparation of old painted surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint on wooden surfaces.
M&L for perparation of new or previously untreated steel surface of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxied zinc chrome primer.
Dismantling of boarding any description fixed in any position with nails . Complete all as specified and directed by Eng-In-Charge.
M&L, for weather boarding of 2nd class softwood, clean sawn, plain, 20 mm thick or feather edged 15 mm to 20 mm thick and fixed with 30 mm laps complete all as specified and directed .
All as per Item no 103 above but except board.
S&F facia boarding of 2nd class soft wood planed one side with but joints 20mm thick and champhered one side and the boarding is matched. Complete all as specified and directed by Eng-In-Charge.
S & F 40mm thick IInd class soft wood boarding in floors & skirting planed one side with butt joints and fixed fixed with nails all as specified.
M & L for 2 mm thick coloured linoleum, laid in floors and sealed with an approved adhesive includind stretching, cutting and fitting. Complete all as specified and directed by Eng-In-Charge.
Hacking out old broken glass any thickness size quality or description from wooden/steel frames glazed with putty or fixed with beads etc.
S&F 3.00mm thick sheet glass ordinary quality and glazing with oil putty or with wooden beads n.exc 0.5 sqm in each pane).
Taking down chowkhat or frame without taking off shutter but n.exc. 1.50 sqm each.
Taking down chowkhat or frame without taking off shutter but exc 1.50 sqm but n.exc. 4.00 sqm each.
Taking down shutter of any description n.exc. 1.00 sqm each.
Taking down shutter exc 1.0 sqm but n. exc 2.00 sqm each.
S&F 2nd class soft wood plain soild,straight chowkats and frame wrought,framed rebated on soild,rounded or chamfered,put together with pinned at joints. Complete all as specified and directed by Eng-In-Charge.
Taking down cement or cement lime plaster on brick or stone walls etc, including raking out joints, hacking for key &scrubbing down with water.
Dismantling posts or struts (wood,steel or RCC) embedded in concrete, brick work, masonry etc. any section, incl taking out embedded portion and making good disturbed ground.
M & L for chequered cement concrete tiles of size 25cm x 25cm x 22 mm thick set jointed in neat cement slurry and pointed with grey cement and pigment incl. 15 mm thick screed bed or bedding layer for laying floor finishes in cement mortar 1:6. Complete all as specified and directed by Eng-In-Charge.
Dismantling of asbestos cement (corrugated, semi corrugated, etc.)sheets in roof coverings. Complete all as specified and directed by Eng-In-Charge.
Demolition brick work or stone/boulder masonry built in cement mortar or cement line mortar including all quoins. Complete all as specified and directed by Eng-In-Charge.
Taking down carefully copper/aluminum point wiring (light. Fan, socket or power) complete, incl fittings such as switches, ceiling roses, pendants, regulators, sockets etc, removing materials to store for keeping in safe custody for reuse at site and making good disturbed surfaces of walls, floors etc.
S&F Point wiring complete with 1100 volts grade PVC FRLS insulated unsheathed cable of copper conductor, multi stranded of size 1.5 Sqmm, single core, drawn through & including PVC rigid concealed conduit, medium grade of suitable size (not less than 20mm dia) duly ISI marked with all accessories such as bends, reducers, spacers, saddles, junction boxes,including modular PVC box 1.6 mm thick dully painted/3mm thick plastic laminated sheet,modular white cover plate and inner plate with frame of suitable size for mounting modular switches/sockets,fan regulators etc complete with and including continuous earth wire of size 1.5 Sqmm, single core, PVC FRLS copper conductor, insulated, unsheathed,stranded (Green colour) connected to common earth dolly. Complete all as specified and directed by Eng-In-Charge, for:- (a) One light/fan point controlled by one single pole one way 5 Amps switch.
M&L for point wiring in PVC casing caping with 1.5 Sqmm size multi stranded FRLS copper conductor cable 1.5 Sqm including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated FRLS cable of size 1.5 Sqmm as earth continuity conductor.(a) One light point/fan point/ex fan point controlled by one 5 Amps switch one way
All as per sr item no. 122 above but One 3 pin 5 Amp socket outlet on same board.
All as per sr item no. 122 above but One 3 pin 5 Amp switch /socket outlet on independent board.
S&F switch piano Flush type, single pole 5/6 amp 240 volts, Complete all as specified and directed by Eng-In-Charge.
S&F Lamp Holder, PVC/ Polycarbonate type with back plate suitable for batten fitting Complete all as specified and directed by Eng-In-Charge.
Supply and fixing ceiling rose 3 terminal / PVC/ Polycarbonate, isolated body. Complete all as specified and directed by Eng-In-Charge.
S&F LED lamp 7 watts 230 Volts 50 Hz. Complete all as specified and directed by Eng-In-Charge.
S&F 1x20/22 W surface and wall mounted LED tube light fitting, with polycarbonate diffuser/ housing and integrated electronic driver, connection to ceiling rose complete. Complete all as specified and directed by Eng-In-Charge.
S & F MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Eng-In-Charge.
S & F MCB, SP 6-32 Amps 415 Volts Gold plus MCB B Curve, 10 KA. Complete all as specified and directed by Eng-In-Charge.
S & F MCB, SPN 32 Amps 415 Volts Gold plus MCB B Curve, 10 KA. Complete all as specified and directed by Eng-In-Charge.
S & F exhaust fan Metallic Range 230 mm sweep, 230 volts, connecting to ceiling rose. Complete all as specified and directed by Eng-In-Charge.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 4 Sqmm twin core cable flat or circular, Complete all as specified and directed by Eng-In-Charge.
Supply and fixing switch socket combination 5A, 2 in 1, 3 pin flush type universal. Complete all as specified and directed by Eng-In-Charge.
S&F LED lamp 15 watts lumen out put (500) length 102mm dia 56 mm base cap B22 ISI marked 230 Volts 50 Hz with all accessories. Complete all as specified and directed by Eng-In-Charge.
S & F Endura rugby energy saving new generation 10W LED IP65 bulkhead luminaire with opal diffuser lamp type 10W LED 6000K. Complete all as specified and directed by Eng-In-Charge.
S & F heavy duty exhaust fan range 300 mm sweep,1400 RPM, 230 volts,with louver shutter, XPM jaali,grouting, connecting to ceiling rose. Complete all as specified and directed by Eng-In-Charge.
M&L for sub main wiring with 2 runs of 4 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 4 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring Complete all as specified and directed by Eng-In-Charge. Note :- Two runs of 4 sqmm and one runs of 4 sqmm cable as earth along with PVC conduit will be measured as one length.
Earthing complete with galvanised steel earth plate electrode of size 60cms x 60cms x 6.0 mm thick as per IS 3043 of 1987 buried directly in to the ground ( earthpit not less than 2.25 m deep below the ground level) with top edge of the plate not less than 1.5 meters below normal ground level, connected to the galvanised earth lead by means of bolts , nuts check nuts and washers of galnanised iron or steel using GI strip 32 x 6 mm as earthing lead as shown in electric plate No-3 of SSR- Part-1 connected to earth strip all as specifed or indicated including testing on completion and necessary excavation and earth work in any type of soil, returning filling, disposal of surplus soil, earth pit in PCC 1 :3:6 type C-1 using 20 mm graded stone aggregate, pit, funnel, 15 mm diia meduim grade watering pipe, 40 mm dia GI light grade earth lead protection pipe, CI frame and cover , wire copper lugs etc mesh, charcoal and common salt in alternate layer and testing complete. Note : The rate is inclusive of necessary earth work, RFR and removal etc Complete all as specified and directed by Eng-In-Charge.
M&L for point wiring in PVC casing caping with 2.5 Sqmm size multi stranded FRLS copper conductor cable including clamps, screws guttier/plug etc PVC unsheathed cable into and including wooden board with bakelite sheet and PVC insulated fire retardant cable of size 2.5 Sqmm as earth continuity conductor. Complete all as specified and directed by Eng-In-Charge. Note:- Proper colour coding to be adopted.
Supply and fixing switch socket combination 5A and 15 A, 2 in 1, 5 pin, flush type universal. Complete all as specified and directed by Eng-In-Charge.
S&F bell ding dong AC 230 volts single pole. Complete all as specified and directed by Eng-In-Charge.
S&F bell push flush type, 6 Amp, 240 volts. Complete all as specified and directed by Eng-In-Charge.
S & F MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, double door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting Complete all as specified and directed by Eng-In-Charge.
S&F house service bracket (hook type complete with 3.0m long GI pipe 40mm dia medium grade, two nos. 90 degree bends MS hook and stay or guy. Complete all as specified and directed by Eng-In-Charge.
S&F 1100 volts grade heavy duty cable PVC insulated aluminium conductor served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 6 Sqmm twin core cable flat or circular, Complete all as specified and directed by Eng-In-Charge.
S& F water heater storage type electric capacity 50 Ltrs. BEE 5 star rated. Complete all as specified and directed by Eng-In-Charge.
S&F linnet LED mirror light 14W 1 feet made of extruded engg plastic suitable for surface mounting on a ceiling/ wall. Complete all as specified and directed by Eng-In-Charge.
S& F VTPN Vertical type distribution boards 6 way with IP-43 IK-09 protection incld 200 Amp bus bar and neutral, ISI marked. Complete all as specified and directed by Eng-In-Charge.
S&F MCCB 4 Pole, 415 V, fixed type, 63 Amps with breaking capacity 16 KA, ISI marked. Complete all as specified and directed by Eng-In-Charge.
M&L for sub main wiring with 2 runs of 10 sqmm PVC insulated multi stranded FRLS copper cable drawn through PVC casing capping of required size with accessories along with 1 run of 10 sqmm copper cable as earth continuity conductor including taking down the old existing submain wiring Complete all as specified and directed by Eng-In-Charge.Note :- Two runs of 10 sqmm and one runs of 10 sqmm cable as earth along with PVC conduit will be measured as one length.
Supply, laying and testing cable XLPE insulated, 1100 volts grade heavy duty cable,armoured, aluminium conductor, suspended by insulating hangers not more than 1 m apart including 4mm dia suspension GI wire with stranded conductor 35 Sqmm 3.5 core cable flat or circular, Complete all as specified and directed by Eng-In-Charge.
M&L for sand cushioning to under ground cable with a layer of sand 8 cm before laying cable and 15 cm after laying. Complete all as specified and directed by Eng-In-Charge.
M&L for Sub class "B" bricks laid dry width wise across the line of cable in treanchs as cable protection. Complete all as specified and directed by Eng-In-Charge.
M/S GHULAM HASSAN MALIK
M/S GHULAM QADIR WANI AND SONS
M/S NISAR AND CO
M/S KULWANT SINGH RAINA AND CO
M/S MANZOOR AHMAD YATOO
M/S IQ ENTERPRISES
M/S G M DAR AND SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .