Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Tender Value
Refer Docs
EMD Value
₹26,920
Closing Date
9 Dec 2025, 1:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, South 24 Pgs. Elect. Divn.
South 24 Parganas Electrical Division 57/2 Diamond Harbour Road Kolkata 700 023
Repairing of existing fire detection devices including 01 (One) year AMC at Diamond Harbour Old Hospital Building, Covid Building, DRS building under DHGMCH.
2025_WBPWD_949243_1
WBPWD/EE/S24PED/eNIT37_2nd Call/2025-26
Open Tender
ELECTRICAL WORKS ORG
Item Rate
365 days
DIAMOND HARBOUR
Please refer Tender documents.
5 documents required · 5 mandatory
₹26,920
South 24 Parganas Electrical Division
29 Jan 2026
14 Nov 2025
11 Dec 2025
14 Nov 2025
9 Dec 2025
22 Nov 2025
21 Nov 2025
Multi Sensor detector/Heat detector.
Manual Call point.
Hooter cum Strobe.
FDA Panel. (Make-Conventional/Morley/Edwards/Siemens)
SITC of fire detection system
Supply , Installation, Testing and commissioning of Multi sensor Detector with base and all other necessary accessories (Make: Edward-Model no-- SIGA PHD)
Supply , Installation, Testing and commissioning of Multi sensor Detector with base and all other necessary accessories (Make:SIEMENS-Model no-- OH-720)
Supply , Installation, Testing and commissioning of Multi Detector with base and all other necessary accessories (Make: Honeywell-Model no-- MI-PTSE-S2 IV)
Supply , Installation, Testing and commissioning of Multi Detector with base and all other necessary accessories (Make: Agni Surakhasha)
Supply , Installation, Testing and commissioning of Heat Detector complete with base and all other necessary accessories( Make: Siemens-Model no-- OH-720)
Supply, installation, testing & commissioning of Inteliigent addressable manual call point complete with all accessories ( Make:siemens-Model no-- FDM-225-RG)
Supply, installation, testing & commissioning of Inteliigent addressable manual call point complete with all accessories ( Make: Edward-Model no-- SIGA 270)
Supply, Installation, Testing & Commissioning of Intelligent addressable loop powered sounder/Hooter (sound output of minimum 90db) cum strobe. ( Make: Siemens-Model no-- FDS226-R)
Supply, Installation, Testing & Commissioning of Intelligent addressable loop powered sounder/Hooter (sound output of minimum 90db) cum strobe. ( Make: -Edward-Model no-- ABS EDWARD HOOTER G1AVRF)
Charges for re-commissioning of existing Fire Detection system at all floors (Multi Sensor Detectors, manual call point, Response Indicator, monitor devices etc & other fire detection system equipments) under panels of existing fire Control panel and making integration of all devices of Fire Detection system with existing fire Control panel with proper checking & functioning of existing loops of the said Panels incl.Cable loop line checking/Voltage checking of the existing system finding faults including rectification of all faults(End to End) .
Supplying & laying of 2 x1.5 sqmm FRLS shielded copper Conductor stranded cables in red/black color and generally confirming to IS-694-2010 and meet the signal cabling requirements (MakeHavells /Finolex/ Polycab / Gloster/ KEI/RR as approved by E.I.C)
Supplying and fixing 20 mm PVC Rigid Conduit 'FR' [Precision Make] of following sizes on wall, ceiling with saddles and other accessories as required and mending good damages to building works.
Supply and fixing of 12V, 7Ah sealed lead acid battery.(Make-EXIDE)
SITC of LED Display Unit of FDA Panel incl. all required accessories by utilizing SMD soldering techniques by agencies own tools and materials to ensure precise repairs and restore to optimal functionality.(Make:- Siemens Model No-FCM2703-Z3)
SITC of Microprocessor based 32 Zone Capable fire alarm control panel fully networkable with each Zone capable of taking atleast 20 devices and each loop should be connected to a dedicated loop card, 1/4 VGA display character alpha-numeric liquid crystal display.The panel shall be Zone addressable type. ( Make: Agni Suraksha).
Committed Expenditure for Maintenance & Operation
Day to day preventive & corrective maintenance of the entire Fire-Detection & Alarm System and panic button system (Siemens/Edwards/Agni Suraksha/Honeywell Morley/Bosch make) installed at different locations within the premises of Diamond Harbour District Hospital, Covid Building, DRS building by providing 01(one) no. Skilled Technician and 01(one) no unskilled Labour on all working days in 1 shift per day on all working days incl. Holidays
Miscellance
Note: 1) All the above rates should be quoted inclusive of all taxes, duties and all ancilery charges with cost of maintenance, servicing, supply & replacement of spares for 1 (One) year from the date of completion.
stage.html
html • 0.02 MB
cancelled_1.pdf
pdf • 0.46 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.25 MB
Tendernotice_2.pdf
PDF • 0.57 MB
Tendernotice_3.pdf
PDF • 0.05 MB
BOQ_2263623.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .