Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAdmitted-Finance | ₹1.6 Cr | L1 | Admitted-Finance |
| 2 | L2₹1.7 Cr+₹15.5 L (9.83%)Admitted-Finance | ₹1.7 Cr+₹15.5 L (9.83%) | L2 | Admitted-Finance |
| 3 | L3₹1.8 Cr+₹17.8 L (11.3%)Admitted-Finance | ₹1.8 Cr+₹17.8 L (11.3%) | L3 | Admitted-Finance |
| 4 | L4₹1.8 Cr+₹26.6 L (16.9%)Admitted-Finance ANANDIPURAM KUSUMKHERA HALDWANI | NAINITAL | UTTARAKHAND | 244713 | ₹1.8 Cr+₹26.6 L (16.9%) | L4 | Admitted-Finance |
| 5 | Rejected-Technical | - | - | Rejected-Technical Not Admitted |
| Sl No | Description | Qty | Unit | M/s SURESH CHANDRA BAJETHA L1 | Neeraj Mishra L4 | surya cont. company L3 | M/S SHRISAI CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|---|
| 1.10 | Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.) | 1,050 | cum | 3,600 ₹37,80,000 | 3,753 ₹39,40,650 | 2,800 ₹29,40,000 Lowest | 3,000 ₹31,50,000 |
| 1.20 | Cement Concrete Pavement Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade),coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 Cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing),spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501 | 1,960 | cum | 4,800 ₹94,08,000 Lowest | 5,782 ₹1,13,32,720 | 5,825 ₹1,14,17,000 | 5,900 ₹1,15,64,000 |
| 1.30 | Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material. | 108 | cum | 25 ₹2,700 Lowest | 36 ₹3,888 | 40 ₹4,320 | 32 ₹3,456 |
| 1.40 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6 | 135 | cum | 5,000 ₹6,75,000 | 5,804 ₹7,83,540 | 6,000 ₹8,10,000 | 4,800 ₹6,48,000 Lowest |
| 1.50 | Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 Brick masonry in 1:4 cement mortar | 162 | cum | 5,000 ₹8,10,000 Lowest | 6,289 ₹10,18,818 | 6,200 ₹10,04,400 | 5,500 ₹8,91,000 |
| 1.60 | Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix Nominal mix (1:2:4) | 84 | cum | 5,000 ₹4,20,000 Lowest | 6,344 ₹5,32,896 | 6,300 ₹5,29,200 | 5,800 ₹4,87,200 |
| 1.70 | Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification | 540 | sqm | 200 ₹1,08,000 | 206 ₹1,11,240 | 200 ₹1,08,000 | 150 ₹81,000 Lowest |
| 1.80 | Providing and laying of hot applied thermoplastic compound of ISI Mark Approved Quality of 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, as per IRC:35 .The finished surface to be level,uniform and free from streaks and holes. | 504.1 | sqm | 400 ₹2,01,640 | 470 ₹2,36,927 | 500 ₹2,52,050 | 350 ₹1,76,435 Lowest |
| 1.90 | Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retroreflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mmdiameter and not less than 30 mm length shall be molded in the RPM body.The reflective raised pavement markers shall also confirm to the MORTHcircular No RW / NH. 33023/10/ 97-DO.III and the length ,height and widthof the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flat surface. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro flectory surface shall not be less than 13.0 sq.cm. The slope or retro – reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CIL not less than values specified in table 1 of MORTH Section 800 page no. 353 and should accompany two year warranty for satisfactory field erformance from the manufacturer. | 1,461 | No | 250 ₹3,65,250 | 322 ₹4,70,442 | 330 ₹4,82,130 | 220 ₹3,21,420 Lowest |
| 2.00 | Semi Reflective Traffic Signs Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to
the ground by mean of properly designed oundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 (600 mm equilateral triangle) | 4 | No | 2,193.5 ₹8,774 | 1,974 ₹7,896 Lowest | 2,100 ₹8,400 | 2,000 ₹8,000 |
Tender Value
Refer Docs
EMD Value
₹4.1 L
Closing Date
27 Oct 2025, 5:00 pmClosed
Superintending Engineer 2nd Circle PWD , Nainital
Office of the Superintending Engineer 2nd Circle PWD , Nainital
Work of Strengthening and Re-Construction of Gorapadav Gola Gate Motor Road through CC of Lalkuan Constituency under District Mining Trust
2025_pwd_86470_1
2490/41-M Dated5-8-2025
Open Tender
Civil Works - Roads
Item Rate
270 days
Haldwani
As per attached SBD
2 documents required · 2 mandatory
₹5,900
EE Construction Division PWD Haldwani
₹4.1 L
Superintending Engineer 2nd Circle PWD , Nainital
4 Nov 2025
21 Aug 2025
28 Oct 2025
21 Aug 2025
27 Oct 2025
4 Sept 2025
21 Aug 2025 - 25 Sept 2025
26 Sept 2025
Amount
Dry Lean Cement Concrete Sub- base (Construction of dry lean cement concrete Sub- base over a prepared sub-grade with coarse and fine aggregate conforming to IS: 383, the size of coarse aggregate not exceeding 25 mm, aggregate cement ratio not to exceed 15:1, aggregate gradation after blending to be as per table 600-1, cement content not to be less than 150 kg/ cum, optimum moisture content to be determined during trial length construction, concrete strength not to be less than 10 Mpa at 7 days, mixed in a batching plant, transported to site, laid with a paver with electronic sensor, compacting with 8-10 tonnes vibratory roller, finishing and curing.)
Cement Concrete Pavement Construction of un-reinforced, dowel jointed at expansion and construction joint only, plain cement concrete pavement, thickness as per design, over a prepared sub base, with 43 grade cement or any other type as per Clause 1501.2.2 M30 (Grade),coarse and fine aggregates conforming to IS:383, maximum size of coarse aggregate not exceeding 25 mm, mixed in a concrete mixer of not less than 0.2 Cum capacity and appropriate weigh batcher using approved mix design, laid in approved fixed side formwork (steel channel, laying and fixing of 125 micron thick polythene film, wedges, steel plates including levelling the formwork as per drawing),spreading the concrete with shovels, rakes, compacted using needle, screed and plate vibrators and finished in continuous operation including provision of contraction and expansion, construction joints, applying debonding strips, primer, sealant, dowel bars, near approaches to bridge/culvert and construction joints, admixtures as approved, curing of concrete slabs for 14-days, using curing compound (where specified) and water finishing to lines and grade as per drawing and Technical Specification Clause 1501
Earthwork in excavation for structures as per drawing and technical specifications Clause 305.1 including setting out, construction of shoring and bracing, removal of stumps and other deleterious material and disposal upto a lead of 50 m, dressing of sides and bottom and backfilling in trenches with excavated suitable material.
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix 1:3:6
Brick masonry work in cement mortar in foundation complete excluding pointing and plastering as per drawing and technical specifications Clauses 600, 1202 & 1203 Brick masonry in 1:4 cement mortar
Providing concrete for plain/ reinforced concrete in open foundations complete as per drawings and technical specifications Clause 802, 803, 1202 & 1203 Nominal mix Nominal mix (1:2:4)
Plastering with Cement Mortar (1:4), 15 mm thick on brickwork in substructure as per technical specification
Providing and laying of hot applied thermoplastic compound of ISI Mark Approved Quality of 2.5 mm thick including reflectorising glass beads @ 250 gms per sqm area, as per IRC:35 .The finished surface to be level,uniform and free from streaks and holes.
Providing and fixing of single mould twin shank reflective road studs of ‘category A’ Raised pavement markers made out of poly carbonate/ABS moulded body and reflective panels with micro prismatic lens capable of providing total internal reflection of the light entering the lens face with retroreflectance and chromaticity values shall be as given in the detailed specifications and the product shall conform to ASTM D4280. The raised pavement marker shall also meet all the testing conditions of ASTM D4280 and fixed to the road surface using the adhesive recommended by the manufacturer. Two cylindrical Polymer Shanks of not less than 20 mmdiameter and not less than 30 mm length shall be molded in the RPM body.The reflective raised pavement markers shall also confirm to the MORTHcircular No RW / NH. 33023/10/ 97-DO.III and the length ,height and widthof the body shall not be less than 100 mm, 15 mm and 90 mm and base of marker shall be flat within 1.3 mm and outermost faces of configuration of marker shall not deviate more than 1.3 mm from a flat surface. The marker shall support a load of 13635 Kg tested in accordance with ASTM D4280. The marker shall withstand flexural strength of 909 kgf force in accordance with ASTM D4280. Marker lenses shall be moulded of Polycarbonate or methyl methecrylate conforming to ASTM D788. The area of each retro flectory surface shall not be less than 13.0 sq.cm. The slope or retro – reflectory surface shall be 35 + 5 degree to base. Each reflector shall have a CIL not less than values specified in table 1 of MORTH Section 800 page no. 353 and should accompany two year warranty for satisfactory field erformance from the manufacturer.
Semi Reflective Traffic Signs Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed oundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 (600 mm equilateral triangle)
Semi Reflective Traffic Signs Providing and fixing of semi reflective cautionary, mandatory and informatory sign board as per IRC:67 made of 1.5 mm thick MS Sheet duly stove white colour in front and gray colour on back with red reflective border of 65 mm width and required letters and figures with reflective tape engineering grade as per Clause 1701.3.9 of MORD for Rural Roads of required shade and colour supported and welded on 47mm x 47 mm x 12 SWG sheet tube firmly fixed to the ground by mean of properly designed oundations with M-15 grade cement concrete 450x450x600 mm, 600 mm below ground level as per approved drawing Clause 1701.2.2 (800 mm X600 mm rectangular)
M/S SHRISAI CONSTRUCTION CO (BID ID -403643)
surya cont. company (BID ID -403880)
Neeraj Mishra (BID ID -403876)
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 4.57 MB
SBDkhanij.pdf
Tender Documents • 1.89 MB
BOQ_102644.xls
BOQ • 0.26 MB
corrig09.pdf
PDF • 0.39 MB
corrigendum.pdf
PDF • 1.37 MB
letteryear.pdf
PDF • 0.74 MB
Date.pdf
PDF • 0.63 MB
cori.pdf
PDF • 0.47 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .