| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.1 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹10.2 L+₹44,986 (4.63%)Rejected-AOC | L2 | Rejected-AOC Other than Lowest | |
| 3 | L3₹10.5 L+₹76,825 (7.90%)Rejected-AOC | L3 | Rejected-AOC Other than Lowest | |
| 4 | L4₹10.7 L+₹95,945 (9.87%)Rejected-AOC | L4 | Rejected-AOC Other than Lowest | |
| 5 | L5₹11.9 L+₹2.2 L (22.8%)Rejected-AOC | L5 | Rejected-AOC Other than Lowest |
Tender Value
₹17 L
EMD Value
₹34,000
Closing Date
14 Jun 2023, 6:00 pmClosed
GE 969 EWS
GE 969 EWS C/O 56 APO
REPAIR/MAINT OF INTERNAL WIRING INCLUDING FITTINGS AND FIXTURES AT GULMARG AND HAWS UNDER GE 969 EWS
2023_MES_598323_1
CANO 969/WS- /2023-24
Open Tender
Civil Works
Item Rate
180 days
GULMARG
Please refer Tender documents.
9 documents required · 9 mandatory
₹500
GE 969 EWS
₹34,000
Yes
20 Jul 2023
25 May 2023
16 Jun 2023
25 May 2023
14 Jun 2023
8 Jun 2023
Amount
Taking down carefully any type point wiring (light, fan, socket or power) complete including conduits/casing- capping with fittings such as light fittings, sockets, switches ceiling roses, board outlets etc and removing the materials/ debris and making good the disturbed surfaces of walls, floor etc to match with the existing surface complete all as specified and as directed.
M&L Point wiring complete with FRLS 1100 Volts grade, 1.5 Sqmm PVC insulated and unsheathed copper conductor single core cable drawn through and including 25 mm medium grade ISI marked PVC casing caping with all accessories such as bends, elbow, reducers, junction boxes /MS boxes duly painted /PVC box factorymade ractangular in shape as required with top cover 3 mm thick plastic laminated sheets of required size, fixedwith screws, for housing switches, sockets, regulators etc, including 1.5 sgmm PVC insulated and unsheathed copper conductor cable as earth continuity wire connected to common earth dolly all as specified and as directed for the following:
(a) One light/ceiling fan point controlled by one switch.
(b) One switch socket combination 5 Amps on independent board.
(c) One switch socket outlet 5 Amps on same board with other switches.
M&L for point wiring in non-metallic PVC casing & caping including all fitting with 2.5 Sq mm size multi stranded FRLS copper conductor cable including clamps, screws gutti /plug etc PVC unsheathed cable into and including Wooden board/sheet steel box of 1.6mm thick with bakelite sheet 3mm thick and PVC insulated fire retardant cable of size 2.5 Sq mm as earth continuity conductor complete all as specified and as directed.
S&F in repair Switch piano flush type single pole, one way 5/6 Amp complete all as specified and as directed.
S&F in repair Switch socket combination 2 in 1, 5 A flush type, multipurpose 3/5 pin suitable for 5 Amp plug top controlled by one switch complete all as specified and as directed.
S&F in repair Socket outlet 2 in 1, 3 Pin, 5 Amp, 230 Volts complete all as specified and as directed.
S&F in repair Switch socket combination 3 pin 16A, flush type multipurpose 3/5 pin 230 Volts complete all as specified and as directed.
S&F in repair Ceiling rose surface bakelite surface 65x50 mm 3 terminals fixed on wall/ceiling and including PVC block complete all as specified and as directed.
S&F in repair LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F in repair Modular switch single pole one way 6 Amps 1 module 240 V complete all as specified and as directed.
S&F in repair Modular Socket, 6A - 2/3 pin combined 2 module 240 V, complete all as specified and as directed.
S&F in repair Modular switch single pole one way 16 Amps 1 module 240 V, complete all as specified and as directed.
S&F in repair Modular Switch socket Combination 16A, 6 pin, 3 module 240 V, complete all as specified and as directed.
S&F in repair Lamp holder, insulated body, threaded dome pattern, suitable for bracket fittings, complete all as specified and as directed.
S&F in repair 6 Amps 2 in 1 switch socket combination 3/5 pin type along with box complete all as specified and as directed.
S&F in repair 16 Amps switch and socket combination 3/5 pin type along with box complete all as specified and as directed.
S&F in repair Bell switch, flush type single pole, one way 5 Amps complete all as specified and as directed.
S&F in repair Bell buzzer AC single phase 220/240 volts complete all as specified and as directed.
S&F in repair 240V, 10 KA B' curve miniature circuit breaker (MCB) of single poles and current carrying capacity 6 AMP, Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 240V, 10 KA 'B curve miniature circuit breaker (MCB) of single poles and current carrying capacity 10 AMP, Complete with connection testing and commissioningcomplete all as specified and as directed.
S&F in repair 240V, 10 KA 'B' Curve miniature circuit breaker (MCB) of single poles and current carrying capacity 16 AMP, Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 240V, 10 KA 'B Curve miniature circuit breaker (MCB) of single poles and.current carrying capacity 20 AMP, Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 240V, 10 KA 'B' Curve miniature circuit breaker (MCB) of single poles and current carrying capacity 32 AMP, Complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair amp rating 240V, 10KA C' curve miniature circuit breaker (MCB) of two poles and current carrying capacity 32 Amp SPN complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair amp rating 240V, 10KA C' curve miniature circuit breaker (MCB) of two poles and current carrying capacity 40 Amp SPN in the MCB DB complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair amp rating 240V, 10KA 'C curve miniature circuit breaker (MCB) of two poles and current carrying capacity 63 Amp SPN complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 415V 10KA 'C' curve miniature circuit breaker (MCB) of three poles and current carrying capacity 32 Amp TP complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 415V 10 KA C Curve miniature circuit breaker (MCB) of four poles and current carrying capacity 40 Amp TPN complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair 415V 10KA C' curve miniature circuit breaker (MCB) of four poles and current carrying capacity 63 Amp TPN B complete with connection testing and commissioning, complete all as specified and as directed.
S&F in repair MCB DB 4 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and as directed.
S&F in repair MCB DB 8 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection, single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and as directed.
S&F in repair MCB DB 12 way sheet metal enclosure SPN 240 volts, 50 Hz, with IP-42 protection,single door with 200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified and as directed.
S&F in repair LED bulb thread/pin type of capacity 10 Watt.
S&F LED lights fitting 1x 20W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and as directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt. 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and as directed.
S&F in repair exhaust fan, steel body AC single Phase. 230V of size 450m sweep with, blades, and frame and louvers complete all as specified and as directed.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 300mm complete all as specified and as directed.
S&F in repair exhaust fan made of sturdy Engineering plastic complete with louvers shutter, voltage 230V, 50 Hz, RPM 1200, Copper winding of sweep 250mm. Complete all as specified and as specified and as directed.
Supply and laying or fixing or passing through pipe in repairs, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed stranded conductor of size 10 sqmm nominal cross section twin core in service connections including taking down.
S&F in repair Sub main wiring using two runs of single core FRLS PVC insulated cable with copper conductor multistranded 1100 volts of sizes 6.0 Sqmm through existing/ new non metalic PVC casing capping including copper earth wire h green colour of size 6.0 Sqmm connection to DB with thimbling complete as specified and directed. (Note:- Two runs of sub main wire including earth wire and rigid non metallic PVC casing capping shall be measured as one unit per RM make of cable)
Earthing complete with galvanised steel earth plate, electrode, 600x600x6.0 mm thick burried directly in ground (earth pit not less than 2.25m deep below normal ground level) connected to galvanised earth lead wire 4.0mm dia by means of nuts, bolts, & washers of GI as shown in electrical plate No. 5 of SSR Part-1. Connected to earthing test point all as specified and including necessary earth pit PCC 1:3:6 chamber be 50mm thick PCC 1:2:4 chamber cover with 6mm dia mild steel reinforcement of 10 cm c/c spacing both ways in lieu of CI cover, watering arrangement shall be made with GI pipe medium grade of 20mm dia including funnel and protection to earth lead shall be provided with Gl pipe light grade 15mm dia upto 7.5 from the earth plate electrode & refilling of soil etc including necessary excavation & earth work in any strata and PCC chamber complete all as specified and directed by Engr-in-Charge including demolish existing earth pit taking out old materials.
S&F heating element (round/traingular) including rubber gasket & washer etc of capacity 1.5 KW suitable for existing make and shape complete all as specified and as directed.
S&F heating element (round/traingular) including rubber gasket & washer etc of capacity 2 KW suitable for existing make and shape complete all as specified and as directed.
S&F Thermostat including rubber / PVC gasket to be set to a temperature not higher than the range of 70 degree Centigrade suitable for existing geysers of capacity 25 / 35/50 Itrs including taking down existing unserviceable thermostat complete all as specified and as directed.
S&F fusible plug melting at 90-100 degrees Centigrade including taking down existing uncerviceable fusible plug complete all as specified and as directed.
S&F PVC connecting pipe 18" long with brass adopters for cold water and connecting up with complete for 25 /35/50 ltrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and as directed.
S&F PVC Connecting pipe 18" long with brass adopters for hot water and connecting up with complete for 25 /35/50 Itrs capacity Geysers including taking down existing unserviceable PVC connecting pipe complete all as specified and as directed.
Servicing of geysers of any capacity by opening of entire geyser and cleaning all the sledges, blockages, dust, etc all as specified and as directed.
S&F round/Square shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and as directed.
S&F LED light fitting 1x9W/1X10W bulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size.
Note:- Schedule of credit Rs 58,350.00 will be deducted from total amount quoted while accepting the bid. Details of schedule of credit is given in tender documents.
M/S KULBIR SINGH SODHI AND CO
M/s Riyaz Enterprises
M/S G M DAR AND SONS
M/S IQ ENTERPRISES
M/S GHULAM NABI KHUROO AND CO
M/S Khan Hussain & Co.
QAZI SONS
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .