Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Fee/PreQual/Technical/Finance JALALIYA BUILDING 1ST FLOOR MASJID ROAD ALUVA ERNAKULAM 683101 | ALUVA | ERNAKULAM | KERALA | 683101 | Admitted-Fee/PreQual/Technical/Finance |
| 2 | Admitted-Fee/PreQual/Technical/Finance | Admitted-Fee/PreQual/Technical/Finance |
| 3 | Admitted-Fee/PreQual/Technical/Finance CHANGANACHERRY GENERAL ELECTRICAL WORK | Admitted-Fee/PreQual/Technical/Finance |
Tender Value
₹9.4 L
EMD Value
₹23,400
Closing Date
20 Oct 2020, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer
O/o the Executive Engineer, Executive Engineer, LSGD, Kottayam Municipality Pin 686001 Kottayam Pin 686001
Electrification
2020_LSGD_382230_2
34/elec/2020-21
Open Tender
Electrical Works
Item Rate
90 days
Kodimatha
Please refer Tender documents.
5 documents required · 5 mandatory
₹1,900
Yes
online
₹23,400
Yes
27 Oct 2020
9 Oct 2020
27 Oct 2020
9 Oct 2020
20 Oct 2020
9 Oct 2020
60 days
Amount
SUPPLY OF D. G SET
'Supply, of 50 KVA/40KW DG set with engine,sttandard accessories with Diesel engine, engine instrument, panel, safety control for engine, alternator, Acoustic Enclosure, fuel tank, battery, standared control pnel etc(specification attached seperately)
Supply anf providing in the following sizes of B class MS pipe conforming to relevant IS specfications complet the heavy gauge specials such as bends, flangs, etc, welded and fixed at appropriate loactions ,providing cork sheet in between the flangs at the joints , bolting the flangs together, painting the pipe , flangeetc with 2 coats heat resistant paint suitable for outdoor applications , fixing the pipe firmly with fabricated structure, wall / any other mechanical support etc as required. 63/ 50 mm Dia or nearest size.
Earth work excavation in ordinary soil and depositing with a lead up to 50 m and lift up to 1.50 m including neat banking
Cement concrete 1:2:4 using 20mm (nominal size) broken stone for reinforced concrete work.
Plain cement concrete 1:4:8 using 40mm ( Normal size ) broken stone. ( m3 )
Reinforcement for R.C.C works, bend tied and placed in position (plain grill requiring bend cold) using tor steel
Brick work in cement mortar 1:6 with country burnt bricks 19cm x 9cm x 9cm for foundation and basement.
Plastering with cement mortar 1:4, 12mm thick one coat.
unloading and errection of 50 KVA DG set on the existing cement concrete platform
Supply, laying and clamping of 1 no. PVC insulated and PVC sheathed armoured aluminium power cable, 1.1 KV grade 3.5 core 35 sqmm with factory made clamp using clamps spacing of clamps not exceeding 60cms, making good the damages , colour washing etc. as required.
Specification as detailed above with 4 core 16 mm with factory made clamp
'Specification of work as detailed above with 2 core 4 sq mm cable
Supply & laying of one number PVC insulated and PVC sheathed armoured aluminium power cable of 1.1KV grade 3.5 core 35 sq mm in the existing RCC/ HUME / STONE WARE/ GI/ DWC pipe as required.
'Specification of work as detailed above with 2 core 4 sq mm cable through existing DWC
Supplying, laying and jointing of 77 / 63 mm or nearest size double wall corrugated (DWC) pipes made out of HDPE conforming to IS 14930 Part II for mechanical protection to underground power cables with all required accessories in ordinary soil 0.75m below ground level including excavation
'Specification of work as detailed above using 40/32 mm DWC
Supplying and providing Brass cable gland for armoured aluminium conductor cable 1.1 KV grade, and making end termination,crimping aluminium tubular cable socket and providing earth clamps for cable gland as per KPWD standards suitable for 35 sq mm 3.5 core cable
Supplying and providing earth clamps for siemens/ tropodur type cable glands of 16 sq mm cable with 12 mm wide x 1 mm thick clip
Specification of work as detailed above for 35 sq mm cable
'Supply of superior quality aluminium tubular cable socket and making core termination of 16 sq mm cables
Specification of work as detailed above for 35 sq mm cable gland
Fabrication of fully partitioned, dust and vermin proof enclosure for panel assembly as per form 4 of IS 8623 (with latest amendments) using 1.60 mm CRCA sheet as per approved design and requirement, with front and rear access facility, bus bar chambers, hinged doors for all switch gear compartments, earthing the doors using 4 sq mm braided copper conductor, providing necessary cut-outs for mounting meters, relays, indication lamps, bus bar interconnection etc, detachable covers for bus bar chamber and cable alley, powder coating the assembly after subjecting to 7 tank process etc as required. CRCA sheet alone be used for the fabrication. Angles/ flats/ slotted angles etc shall not be used for the fabrication of panel assembly. The measurments should be taken the area of the complete sheets used for panel board including partitions, folding, shrouding etc. including control wiring
'Fabrication, supply & fixing main bus bar system and interconnections with electrolytic grade copper strips as per PWD standard
Fabrication, supply & fixing earth bus system with copper strip/ conductor and connecting all accessories as per rule including g tinning the points of contacts etc as required
upply and fixing'A' section neoprene beeding suitable for 1.60/ 2.00 mm sheet along the periphery of doors/ other detachable compartments to make the panel assembly dust & vermin proof including sticking with glue
Supply and providing 3 mm thick SMC sheets in the panel as barriers & shrouding using required bolts and nuts including cutting to shape etc., as required.
Carrying out control wiring.for panel with normal meters and indication lamps alone with 650/1100 V grade PVC insulated stranded single core copper conductor cables 1.50 sq mm single run with required socketsconforming to IS 694 part I 1990 for interconnecting the control devices/ equipments including providing suitable size insulated sockets at the termination points or soldered properly, providing numbering ferrules for the proper identification of the wiring, keeping the wiring firm by suitable tie/ tie mounts/ PVC duct etc as required.
Supply, conveyance and fixing of 125A, 35/36 kA (Ics=100%Icu), 4 pole, current limiting type MCCB with microprocessor based release with overload setting of 50 - 100% having adjustable OL & SC conforming to IS 13947 suitable for 440 V, 50 Hz, AC supply in the existing panel assembly as required( in the Generator panel)
Supply and providing 63 A, 25/35 kA (Ics=100%Icu), 3 pole, current limiting type MCCB having thermal setting range of 80 - 100% with thermal magnetic release having adjustable OL
Supply and providing200 A, AC 23 A, 4 pole on-load COS
Supply and providing rotory kit for MCCB
Supply and installation of 6-32A 10KA, SP MCB( C curve)suitable for 50 Hz , AC supply conforming to IS 8828-1995/ IEC 60898 of the following current ratings in the existing enclosure and giving connections as required
LED indicators for all voltage ranges - Red, Green colour
Supply and providing plate earthing as per IS 3043 with 600x600x6.30 mm GI/CI earth plate, 20 mm GI watering pipe fixed to the earth plate with 20 x 3 mm GI clamps including inspection chamber complete with 300 x 300 x 6 mm cast iron gully trap covering at the top of the inspection chamber of earth pit and providing as test joint 25 x 3 mm GI strip (2 nos) of minimum length 30 cm and providing earth lead from the test joint to the earth electrode using 25 x 3 mm GI strip including cutting, drilling necessary holes on the test joint ( in ordinary rock - soft laterite soil)as per KPWD standard
Supply and clamping 25 x 3 mm copper strip tinned at the points of contacts on surface of wall/ parapet/ existing cable tray using clamps fabricated from 20 x 3 mm GI flat duly painted or heavy duty GI spacer saddles, spacing of clamps not exceeding 1m, making good the damages, colour washing etc. as required
Supply and laying 25 x 3 mm copper strip tinned at the points of contacts laid 0.60 m below ground level including excavating trench of suitable size and refilling etc. as required (in ordinary soil).
'Supply and drawing bare earthing conductors 2.65 mm copper (12 SWG) along with wiring/ cables and giving connection as required.
1'Supply and providing 25x6 mm brass bolt and nut with washers on the existing MS box / earth bus etc. as required including drilling necessary holes as required
1Supply and providing 5 Kg. Dry Chemical Powder type Fire Extinguisher with hose and clamps including fixing it to wall as required.
Painting letters or figures of 2.50 cm, 4 cm or 5 cm height with enamel paint as identification mark to SB, DB, panel board etc as required
'Specification as detailed above of 6.5 cm, 8 cm or 13 cmheight
'charges for refixing the existing tube fitting at new locations uusing additional 3 core connection cable if required
1Supply and Installation / Fixing / Provision of Outdoor type HENSEL make (600X300x214 mm Mi 2410) Thermoplastic Modular Panel enclosure with transparent Polycarbonate Lid, shock proof, IP65 (Weather Proof),rust , dust , water,corrosion proof having internally Embedded gasket on both lid and flap suitable to fix Single Phase / Three Phase Energy Meter in suitable base plate and having a provision for Fuse / MCB cutout with complete tamper proof SEALING facility.
Supply and fixing 160 A, 415 V Backelite fuse fittingin the existing meter board and giving connections etc.
160 A, bolted offset tag type fuse link of size A1L
160 A, 415 V, 2 way neutral link mounted on DMC/ SMC base
Fees to be paid to Electrical inspecterate towards prepertion of scheme of the complete electrrical installation for submitting to the Electrical inspecterate ,prepering all the documentation including payment of the statutary fees to be paid to Electrical inspecterate for getting sanction of energisation of the DG set.
Charges for preparing drawing of the Existing Electrical installation after completion of the present work and preparing completion report in KSEB service connection application form and submitting to the consumer for availng 3 phase service connection/Load regularisation
Electro Guard Power Solutions
M Y ASSOCIATES
Bidder Name
M Y ASSOCIATES
Generic Power Pvt Ltd
Electro Guard Power Solutions
stage.html
html • 0.02 MB
finance_555327.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .