Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹26.1 LAccepted-AOC 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L1 | Accepted-AOC BEING THE LOWEST BIDDER | |
| 2 | L2₹31.4 L+₹4.7 L (17.6%)Rejected-Finance MEGHA SADAN GAGANNAGAR CURTI PONDA GOA 403401 | PONDA | SOUTH GOA | GOA | 403401 | L2 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 3 | L3₹33.2 L+₹6.5 L (24.5%)Rejected-Finance 0 BADRI ELECTRICALS NEAR SHRIGOR FALI NEAR ANADABAWA CHAKLO JAMNAGAR GUJARAT 361001 UDYAM GJ 10 0001822 | JAMNAGAR | GUJARAT | 361001 | L3 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 4 | L4₹34.3 L+₹7.6 L (28.7%)Rejected-Finance | L4 | Rejected-Finance OTHER THAN THE LOWEST BIDDER | |
| 5 | L5₹35.0 L+₹8.3 L (31.2%)Rejected-Finance 141 SHANTI NAGAR MODEL TOWN MODEL TOWN PANIPAT HARYANA 132103 | PANIPAT | HARYANA | 132103 | L5 | Rejected-Finance OTHER THAN THE LOWEST BIDDER |
Tender Value
₹30 L
EMD Value
₹60,000
Closing Date
16 Oct 2024, 6:00 pmClosed
GE (AF) BARODA
GE (AF) BARODA ,DARJIPURA , GUJARAT-390022
REPAIR/ MAINTENACE OF LT CABLE/ METER BOX/ ENERGY METER/ EARTHINGS AT DARJIPURA AT AFS BARODA
2024_MES_676473_1
8926/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE (AF) BARODA, DARJIPURA
AS PER NOTICE OF TENDER
8 documents required · 8 mandatory
₹500
Yes
GE (AF) BARODA
₹60,000
Yes
26 Nov 2024
24 Sept 2024
18 Oct 2024
24 Sept 2024
16 Oct 2024
9 Oct 2024
25 Sept 2024 - 9 Oct 2024
Amount
S & F meter box panel indoor type wall mounted suitable for fixing of 04 Nos of 1 Ph metering unit made out of CRCA sheet 2mm thick of powder coated incl power wiring with minimum 10 sqmm PVC insulated FRLS multi stranded copper conductor and transparent toughened glass of suitable size with following Accessories complete all as specified and directed :- a) MCCB 100 Amp 4 pole 16 KA -01 Nos (As incommer) b) Copper busbar of 300 Amp suitable for 4 wire system mounted on rubber insulators (Outgoing) (c) MCB 63 Amp SPN -04 Nos (d) MCB SPN 32 Amp-01 Nos (for Staircase) (e) Separate compartment for 4 Nos metering units alongwith single phase smart energy meter 10 - 60 Amp BIS 16444 2015 Reaffirmed 2020
Supplying and fixing smart three phase four wire energy meter BIS 16444 : 2015 (Reaffirmed 2020) marked in existing meter board/ floor panels having current range 10-60 Amp, 415 Volts,accuracy class 1.0 complete all as specified and directed.
Supplying and fixing smart single phase two wire energy meter BIS 16444 2015 (Reaffirmed 2020) marked in existing meter board/ floor panels having current range 10-60 Amp, 240 Volts , accuracy class 1.0 omplete all as specified and directed.
Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door type size not less then size 1500mm W x 1500mm H x 500mm D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 300 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder pillar complete feeder pillar box shall be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of following all as specified and directed :-
Incomer:-
(a) MCCB FP 200 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 6 to 9.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
(b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Outgoing :-
(c) MCCB FP 100 A 16 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -04 Nos
Metering Compartment
(h) Digital Multifunction meter having for measuring KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos
(i) RYB LED incating lamp -3 Nos
Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item. (ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly. (iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or depositing in MES Yard store. This will not measured as schedule Credit items
Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door type size not less then size 1500mm W x 1500mm H x 500mm D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 400 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B-2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder pillar. The complete feeder pillar box shall be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of following all as specified and directed :- (Location :- Near Old Darjipura office)
Incomer
(a) MCCB FP 250 A 36 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 6 to 9 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
(b) 4 Nos Aluminium Bus bars of 400 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Outgoing :-
(c) MCCB TP 100 A 16 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -06 Nos
Metering Compartment
(h) Digital Multifunction meter having for measuring KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos
(i) RYB LED incating lamp -3 Nos
Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item. (ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly. (iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or depositing in MES Yard store. This will not measured as schedule Credit items
Supply, install, commissioning and testing factory made (including CPRI approved manufacturer) LT panel box (KIOSK) out door type size not less then size 1800mm W x 1800 mm H x 550mm D platform mounted suitable for 415 volt , 3 phases, 4 wire , 50 Hz AC supply system all as specified and directed having busbar chamber with 4 Nos insulated AL bus bars 600 amps rating installed on porcelain insulators, the panel shall be dust and vermin proof double door made of 3.15 mm CRCA MS sheet outer & inner and individual compartment for MCCB/ volt/Amps meter and 50 x 50 x 6 mm thick angle iron for base frame work having angle iron 4 Nos each Suitable long welded to frame/cubical and grouted in ground upto 0.5 Meter by using PCC 1:2:4 B2 of Suitable size the ground over the ground level upto 1 Mtr height . 2 Nos earth terminal to be welded with feeder pillar. The complete feeder pillar box shall be anti corrosive coating and finally epoxy polyester powder coating of flint grey shade (RAL-7032) including internal wiring with PVC insulated solid copper conductor FRLS cables appropriate size but not less than 2.5 Sqmm. Front and back opening type for cable entry with double door shutter including locking arrangement as per manufacturers with 2 Keys reconnecting all existing UG cable with suitable lugs for incoming/outgoing feeders and comprising of all as specified :- (Location :- Near Old Darjipura office)
Incomer
(a) MCCB FP 400 A 50 kA with Electronic microprocessor release with over load Zone of adjustment 0.4 to 1.0 In and Electronic release with Short circuit Zone of adjustment 1.5 to 10.0 Ir. (Adjusted current) with time with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -01 no
(b) 4 Nos Aluminium Bus bars of 600 Amp current rating capacity, of suitable size of length as actually required at site for 3 phase and neutral, mounted on epoxy/FRP bus bar insulator complete with nut bolt fixing arrangement complete - 01 set
Outgoing :-
(c) MCCB TP 160 A 25 kA with Adjustable Thermal release for over load 0.7 to 1.0 and Adjustable magnetic release (10.0 In) for Short circuit with Extended Rotary Handle vari-depth type and Spreader between phases and neutral. -06 Nos
Metering Compartment
(h) Digital Multifunction meter having for measuring KW, KVA KVRa, KWAH, KVAH , Pf, Hz etc-1Nos
(i) RYB LED incating lamp -3 Nos
Note :- (i) Cost of taking out old unserviceable panel is deemed to be included with unit rate of item. (ii) Earth work, PCC base etc is deemed to be included with unit rate of item. (iii) All MCCB to be onstalled vertically therefor panel shall be designed accordingly. (iv) Taking Out Existing MCCBs of any Capacity from old LT Panel to be fixed in any other LT Panel Board wherever required and rate will be inclusive in this item for fixing or depositing in MES Yard store. This will not measured as schedule Credit items
Excavation in trenches, n. exc 1.5 Mtr wide and n. exc 1.5 Mtr in depth for foundation/laying of cable and getting out in soft/loose soil complete all as specified and directed.
Removing of excavated soil to a distance n. Exc 50 Mtr and depositing where directed at a level n. Exc 1.5 Mtr above the starting point complete all as specified and directed.
Returning, filling in including spreading, levelling, watering and well ramming in layers n. Exc 25 cm thick complete all as specified and directed.
M&L PCC 1:2:4type B1 20mm graded agregate in foundation of the LT Panel including form work complete all as specified and directed.
Supply & spread unwashed dry river sand for sand cushioning and covering the under ground cable in trenches complete all as specified and directed. (Note :- Punning thickness shall be measured.)
Supplying and laying unreinforced precast concrete cable cover, Type 2, flat, size 300mm x 180mm x 40mm complete all as specified and directed.
Taking out existing unserviceable LT cable any size complete all as specified and directed
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 4 core 16 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed.
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 25 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed.
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 35 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 50 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 95 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 120 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed.
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 150 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed.
Supply laying testing and comminssioning of XLPE insulated LT U/G cable heavy duty , 1100 volts grade, galvanized wire armoured and PVC sheathed with multistranded aluminium conductor of size 3.5 core 185 Sqmm laid in trenches or fixed on wall (including saddle clip) or poles drawn through pipes complete all as specified and directed.
M&L for straight through joint outdoor type for LT UG cable including jointing kits heat srinkable type complete suitable for aluminium conductor cables complete all as specified and directed of the following size. Make : Denson, M-Seal or equivalent make approved by GE.
Size of 25 to 50 sqmm 3.5 core
Size of 70 to 120 sqmm 3.5 core
Size of 150 to 185 sqmm 3.5 core
S&F in repairs MCCB 400 Amps, 4 pole, breaking capacity 36 kA, with thermal Magnetic release adujustable type fixed in existing panel & connecting complete all as specified & directed.
S&F in repairs MCCB 200 Amps, 4 pole, breaking capacity 25 kA, with thermal Magnetic release adujustable type fixed in existing panel & connecting complete all as specified & directed.
S&F in repairs MCCB 100 Amps, 4 pole, breaking capacity 25 kA, with thermal Magnetic release adujustable type fixed in existing panel & connecting complete all as specified & directed.
M&L for Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as GI wire of 4 mm dia size by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation&earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 20 mm bore medium grade GI watering pipe, lugs, 15 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra.
M&L Earthing complete with galvanised steel earth electrode 60 cm x 60 cm x 6 mm burried directly in ground vertically to a depth not less than 2.25 metre below normal ground level with top edge of earth plate at a depth not less than 1.5 metre below ground level connected to and including galvanised earth lead as GI strip of 32X6mm size by means of bolts,nuts, check nuts and washer etc made of galvanised iron and connected to earthing test point all as shown in electrical plate No.3 of SSR Part I 2009 and as specified or indicated and testing on completion including excavation&earth work in any type of strata, PCC (1:3:6) type C1 earthing chamber, precast RCC slab 50 mm thick in reinforced cement concrete (1:2:4) type B1 reinforced with welded steel wire fabric (XPM jali weight not less than 4 Kg/Sqm), cast iron frame, funnel with wire mesh, 40 mm bore medium grade GI watering pipe, lugs, 40 mm bore medium grade GI protection pipe, test point etc. complete all as specified and directed. Note: (i) Rate quoted under this item is deemed to include the cost of 7.5m length of earth lead and its protection tube. Any addition in length shall be measured and paid extra.
M/S HARI CONSTRUCTION (BID ID -3141373)
Badri Electricals (BID ID -3140677)
motwani and associate (BID ID -3140870)
Chanda Construction Co. (BID ID -3141384)
M/s Jagdish Machinery Stores (BID ID -3141144)
ARTI CONSTRUCTION (BID ID -3141048)
Hirachand Sunderji and co (BID ID -3141290)
K A ELECTRIC CO (BID ID -3140748)
Dighard Electricals (BID ID -3141194)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .