Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.0 LAccepted-AOC | L1 | Accepted-AOC Lowest | |
| 2 | L2₹3.2 L+₹16,689.68 (5.53%)Rejected-AOC | L2 | Rejected-AOC Second lowest |
| Sl No | Description | Qty | Unit | K Gopakumar L1 | A SHIBU L2 |
|---|---|---|---|---|---|
| 1.00Roof repair works | |||||
| 1.00 | OD176547/2024-2025:Labour engaged for demolishing and removing existing A P P sheet over roofs slab , as per the direction of Engineer in charge. | 20.64 | sqm | 118.13 ₹2,438.2 Lowest | 124.66 ₹2,572.98 |
| 1.00 | 15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm | 21.36 | sqm | 77.16 ₹1,648.14 Lowest | 81.43 ₹1,739.34 |
| 1.00 | 15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. | 21.36 | sqm | 57.47 ₹1,227.56 Lowest | 60.65 ₹1,295.48 |
| 1.00 | 26.28.1:Chipping of unsound/weak concrete material from slabs, beams, columns etc.
with manual Chisel and/ or by standard power driven percussion type or of
approved make including tapering of all edges, making square shoulders of
cavities including cleaning the exposed concrete surface and reinforcement
with wire brushes etc. and disposal of debris for all lead and lifts all complete
as per direction of Engineer-In-Charge75mm average thickness | 42.72 | sqm | 397.91 ₹16,998.72 Lowest | 419.91 ₹17,938.56 |
| 1.00 | OD243707/2024-2025:Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete (21.19.3) above 20mm width. (Backer rod + PU sealant) | 21.4 | metre | 1,624.53 ₹34,764.94 Lowest | 1,714.32 ₹36,686.45 |
| 1.01 | OD243706/2024-2025:Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per direction of Engineer-In- Charge. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system. Mixing of Epoxy Adhesive Shalibind PPE premix each component individually. Proportion 2 parts of component A to 1 part of component B by weight and mix about for 3 minutes with a low speed drill and paddle mixer until uniform in colour. Apply shalibond PPE adhesive on both sides of the joint. Place the activated HS Flex Tape sheet / strip in position on to the epoxy adhesive and using a hard roller force the sheeting into the epoxy and exclude air through the special perforations until the adhesive comes through the perforations. Roof Joint up to 100 mm gap. (5.46.1) | 21.4 | metre | 4,337.31 ₹92,818.43 Lowest | 4,577.07 ₹97,949.3 |
| 1.01 | OD243548/2024-2025:Providing 1mm thick plain aluminium sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and with suitable washers filled with white lead, including a coat of approved aluminium primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2 | 5.5 | sqm | 1,382.29 ₹7,602.6 Lowest | 1,458.7 ₹8,022.85 |
| 1.01 | 26.31.1:Providing, mixing and applying bonding coat of approved adhesive on chipped
portion of RCC as per specifications and direction of Engineer-In-charge
complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer | 23.4 | sqm | 150.16 ₹3,513.74 Lowest | 158.46 ₹3,707.96 |
| 1.01 | 50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete | 165.9 | kg | 234.88 ₹38,966.59 Lowest | 247.86 ₹41,119.97 |
Tender Value
₹3.0 L
EMD Value
₹7,586
Closing Date
5 Jul 2025, 4:00 pmClosed
AEE
O/o the AEE KLC Subdivision No.1 PWD TVPM
GENERAL KLC Roof Repair works Urgent water proofing works to the West side terrace roof of Assembly building near to stair room and allied civil works General Civil Work
2025_PWD_773287_1
DB1/PWD/BLDG/TR/20335/2024
Open Tender
Civil Works - Buildings
Item Rate
60 days
KLC, TVPM
Please refer Tender documents.
10 documents required · 10 mandatory
₹670
₹7,586
20 Sept 2025
1 Jul 2025
7 Jul 2025
1 Jul 2025
5 Jul 2025
1 Jul 2025
Amount
Roof repair works
OD176547/2024-2025:Labour engaged for demolishing and removing existing A P P sheet over roofs slab , as per the direction of Engineer in charge.
15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
15.56:Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead.
26.28.1:Chipping of unsound/weak concrete material from slabs, beams, columns etc. with manual Chisel and/ or by standard power driven percussion type or of approved make including tapering of all edges, making square shoulders of cavities including cleaning the exposed concrete surface and reinforcement with wire brushes etc. and disposal of debris for all lead and lifts all complete as per direction of Engineer-In-Charge75mm average thickness
OD243707/2024-2025:Filling the gap in between aluminium/ stone/ wood frame and adjacent RCC/ Brick/ Stone/ wood/ Ceramic/ Gypsum work by providing weather/structural non sag elastomeric PU sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete (21.19.3) above 20mm width. (Backer rod + PU sealant)
OD243706/2024-2025:Providing and fixing of expansion joint system of approved make and manufactures for various roof locations as per direction of Engineer-In- Charge. The system shall be such that it provides watertight roof to roof/roof to corner joint cover expansion control system. Mixing of Epoxy Adhesive Shalibind PPE premix each component individually. Proportion 2 parts of component A to 1 part of component B by weight and mix about for 3 minutes with a low speed drill and paddle mixer until uniform in colour. Apply shalibond PPE adhesive on both sides of the joint. Place the activated HS Flex Tape sheet / strip in position on to the epoxy adhesive and using a hard roller force the sheeting into the epoxy and exclude air through the special perforations until the adhesive comes through the perforations. Roof Joint up to 100 mm gap. (5.46.1)
OD243548/2024-2025:Providing 1mm thick plain aluminium sheet roofing including vertical/ curved surface fixed with polymer coated J or L hooks, bolts and nuts 8 mm diameter with bitumen and with suitable washers filled with white lead, including a coat of approved aluminium primer and two coats of approved paint on overlapping of sheets complete ( up to any pitch in horizontal / vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.1.00 mm thick with zinc coating not less than 275 gm/m2
26.31.1:Providing, mixing and applying bonding coat of approved adhesive on chipped portion of RCC as per specifications and direction of Engineer-In-charge complete in all respect.SBR Polymer (@10% of cement weight) modified cementitious bond coat @2.2 kg cement per sqm of surface area mixed with specified proportion of approved polymer
50.10.1:Steel work in built up G I tubular ( round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting,fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
12.50:Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
OD253949/2024-2025: Labour engaged for shifting demolished tiles and debris from 8-8 level to Ground floor , as per the direction of Engineer in charge.
26.33.2:Providing, mixing and applying SBR polymer (of approved make @ minimum 2% by wt. of cement used) modified plain/reinforced cement concrete for structural members having minimum characteristic compressive strength [with ordinary portland cement, coarse sand and graded stone aggregate of 10mm maximum size in proportion as per design criteria] with specified average thickness. Note: Rates shall be for finished surface area of concrete and shall include the cost of labour, concrete and appropriate approved Super-Plasticiser for rendering concrete as flowable and SBR polymer but shall exclude cost of reinforcement, bond coat, Shear Keys, centering and shuttering, strutting, propping etc (Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding/tapping with a blunt metal instrument)75mm thick in Grade M 25 with cement content not less than 330 kg per cum
26.32.1:Providing, mixing and applying SBR polymer (of approved make) modified Cement mortar in proportion of 1:4 (1 cement: 4 graded coarse sand with polymer minimum 2% by wt. of cement used) as per specifications and directions of Engineer-in-charge. Note: Measurement and payment: The pre-measurement of thickness shall be done just after the surface preparation is completed and Payment under this item shall be made only after proper wet curing has been done and surface has been satisfactorily evaluated by sounding / tapping with a blunt metal instrument and/or the 75mm size cube crushing strength at the end of 28 days to be not less than 30 N/Sqmm2).12 mm average thickness.
22.20.1:Providing and laying APP ( Atctic Polypropylene Polymer) modified prefabricated five layer 3 mm thick water proofing membrane, black finished reinforced with non- woven polyester matt consisting of a coat of bitumen primer for bitumen membrane @ 0.40 litre/ sqm by the same membrane manufacture of density at 250C, 0.87-0.89 kg/ litre and viscocity 70-160 cps. OVER the primer coat the layer of membrane shall be laid using Butane Torch and sealing all joints etc., and preparing the surface complete. The vital physical and chemical parameters of the membrane shall be as under: Joint strength in longitudinal and transverse direction at 230C as 650/450N/5CM. Tear strength in longitudinal and transverse direction as 300/250N. Softening point of membrane not less than 1500C. Cold flexibility shall be up to - 2C when tested in accordance with ASTM, D - 5147. The laying of membrane shall be got done through the authorised applicator of the manufacturer of membrane:3 mm thick
13.63.1:Painting with aluminium paint of approved brand and manufacture to give an even shade.Two or more coats on new work
OD260697/2024-2025:Micro concreting using high strength non shrink, pourable / pumpable grout with 10mm down size aggregate with water binder ration 0.135
A SHIBU (BID ID -2238709)
Bidder Name
K Gopakumar
A SHIBU
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1262828.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .