Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.6 LAccepted-AOC | L1 | Accepted-AOC L1 |
Tender Value
₹9.4 L
EMD Value
₹23,412
Closing Date
13 Feb 2023, 6:00 pmClosed
aee
aee
Government Secretariat, Thiruvananthapuram Replacement of damaged ductable Air conditioner units in Finance Development hall and Main hall (ReTender)
2023_PWD_550953_2
ESDT/ET_168/2022-23
Open Tender
Electrical Works
Item Wise
30 days
tvpm
Please refer Tender documents.
6 documents required · 6 mandatory
₹2,065
₹23,412
11 Apr 2023
6 Feb 2023
16 Feb 2023
6 Feb 2023
13 Feb 2023
6 Feb 2023
Amount
Part-1 Air conditioning
OD163057/2022-2023:Supply, Installation, Testing, Commissioning of 17 TR, 6800 CFM nominal capacity ductable split air conditioner unit consisting of ceiling suspended ducted type indoor unit, twin circuit out door unit with efficient scroll compressor conforming to IS 1391 (Part2/92) suitable for operating 415+-10% ,50 Hz three phase AC supply with power consumption norms as specified in the standards operating on R-410A / R407C / R22 non CFC refrigerant with condensing and evaporating units of copper tubes cable for cooling , dehumidifying ,air circulating and bio filter activated carbon cum electrostatic filter etc including microprocessor control with s remote control etc. with all standard fittings, safety device like HP/LP cutout single phase preventer, overload relays, microprocessor control with digital display etc as required (Make- Hitachi/ Blue star/ Carrier)
OD163058/2022-2023:Supply, Installation, Testing, Commissioning of 11 TR, 4400 CFM nominal capacity ductable split air conditioner unit consisting of ceiling suspended ducted type indoor unit, twin circuit out door unit with efficient scroll compressor conforming to IS 1391 (Part2/92) suitable for operating 415+-10% ,50 Hz three phase AC supply with power consumption norms as specified in the standards operating on R-410A / R407C / R22 non CFC refrigerant with condensing and evaporating units of copper tubes cable for cooling , dehumidifying ,air circulating and bio filter activated carbon cum electrostatic filter etc including microprocessor control with s remote control etc. with all standard fittings, safety device like HP/LP cutout single phase preventer, overload relays, microprocessor control with digital display etc as required. (Make- Hitachi/ Blue star/ Carrier)
16.12.2.2:Supply, Installation, balancing and commissioning of fabricated at site GSS sheet metal rectangular / round ducting complete with neoprene rubber gaskets, elbows, splitter dampers, vanes, hangers, supports, etc as per approved drawings and specifications of following sheet thickness complete as required.Site fabricated GSS sheet metal rectangular ducting as per IS 655-2006 for 0.8. mm thick
OD163060/2022-2023:Supply and providing heavy duct flexible double layer fire-retardant canvas connection with rexin shall be provided at the outlet of Ductable split/package unit and also for expand joints with necessary flanges, supports etc as required
OD163061/2022-2023:Supply and providing hard drawn copper refrigerant piping including all accessories, properly brazed and insulated with chemically cross linked nitrile rubber fire retardant grade Class O insulation with necessary supports as required. - 11/8 Inch (28.6 mm)
OD163062/2022-2023:Supply and providing hard drawn copper refrigerant piping including all accessories, properly brazed and insulated with chemically cross linked nitrile rubber fire retardant grade Class O insulation with necessary supports as required. - 5/8 Inch (15.9 mm) 22 gauge
OD163545/2022-2023:Supply and providing hard drawn copper refrigerant piping including all accessories, properly brazed and insulated with chemically cross linked nitrile rubber fire retardant grade Class O insulation with necessary supports as required. - 7/8 Inch (22.225 mm) 22 gauge
OD163546/2022-2023:Supply and providing hard drawn copper refrigerant piping including all accessories, properly brazed and insulated with chemically cross linked nitrile rubber fire retardant grade Class O insulation with necessary supports as required. - 1/2 Inch (12.7 mm) 22 gauge
OD163085/2022-2023:Supply and fabrication conveyance and installation of angle iron frame work for wall/floor mounting Out Door Units
90.6.5.4:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.2 core 1.50 sq mm
90.6.5.11:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 1.50 sq mm
90.6.5.12:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.3 core 2.50 sq mm
90.6.5.21:Supply and drawing the following sizes of multi-core PVC insulated & FRLS PVC sheathed 650/1100 V grade copper conductor round flexible cables conforming to IS 694 part I 1960 in the existing surface / recess conduit as required including giving necessary connections of the following sizes.4 core 6.00 sq mm
90.16.1.3:Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG)
90.16.5.3:Supply of superior quality copper earth socket for the following size of earth conductor including crimping etc. as required.3.15 mm (10 SWG)
OD163059/2022-2023:Uninstalling the existing damaged indoor and outdoor units of 11 TR/17TR ductable split A/C units by removing their supports, duct connections, copper refrigerant piping etc. as required, take the outdoor units from the top of finance development hall by using cranes and conveys it in to the section store without any damage.
Bidder Name
INTIMATE REFRIGERATION AND AIR CONDITIONS
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_817330.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .