Karnataka Neeravari Nigam Limited
Shri V S Pattar TA
Operation and Maintenance of Pumping Machinaries, Transformer Yard of Devalapur LIS for the year 2025-26
KNNL/2025-26/LI/WORK_INDENT3648/CALL-3
KNNL/2025-26/LI/WORK_INDENT3648/CALL-3
Open
Lift Irrigation Scheme
Electronic Documents, First(One Cover)
KNNL Division W and M Div Navilutheertha
7 documents required · 7 mandatory
₹790
₹66,500
26 Mar 2026
13 Mar 2026
23 Mar 2026
Operation and Maintenance of Pumping Machinaries Transformer Yard of Devalapur LIS for the year 2025-26
Transportation of transformer - Cost of Haulage on surfaced road excluding loading and Unloading - 4000 t-km (two transformer of capacity 6+2 total 8t for a distance of 500 km from Bengaluru to Devala...
Mobile Hydraulic Crane 10 ton capacity for Shifting Transformer
Erection of Transformer - Moving the Transformer to the plinth.400 t/m (Maximum allowable distance is 50 metre, two transformer of capacity 6+2 total 8t
Testing & Commissioning of Power Transformers-Inspection of wires and ferrules. Inspection of wiring of protective devices, cooling fans, oil flow pumps, OLTC, RTCC, bushing etc
Testing & Commissioning of Power Transformers- Testing - Ratio Test, SC Test, Excitation Current Test/Highpot Test,Magnetic Balance Test, Vector Group Test, Induced High Voltage Test, OLTC Operation -...
Supply of BATTERY SET Plante Plate Type 110 V, 100 AH
Battery set - Labour charges, Installing, assembling, filling of acid, wiring, assisting, test-charging and discharging
VOLTAGE TRANSFORMER: Single phase, oil filled, outdoor type VT with terminal connector suitable for Al. tube/conductor with marshalling box etc complete as per technical specification. Ratio: 33 kV /s...
Requirement of Power Connectors 'T' Clamps for ACSR Conductor, Single Lynx to Single Lynx
Supply of BATTERY CHARGER: 110 V, 15 A float and 30 A boost (with float and boost battery charger as per technical specification)
Battery Set and Charger- Installing, assembling, filling of acid, wiring, assisting, test-charging and discharging Battery set 110V
Erection of Battery Charger and wiring
Testing & Commissioning of Battery Charger
Repairs and reconditioning of ACB
Repairs and reconditioning of ACB at LIS including disconnecting power cable feeder connection dismantling the equipment the bus bar, insulators moving / fixed contac...
Repairs and reconditioning of VCB
Repairs and reconditioning of 3.3 KV VCB at LIS including disconnecting power cable feeder connection dismantling reconditioning of equipment by providing and fixing ...
Repairs, rewiring, servicing, reconditioning and testing of TR 33kv C&R Panel
Repairs and reconditioning of 33kv C&R Panels at LIS including disconnecting power cable connection dismantling reconditi...
Repairs of FCMA Soft starter 3.3 KVA
Labour charges for disconnecting of power supply and 2 run starter connected cable pothead and other spare parts of soft starter panel. Cleaning the panel board wi...
Dismantling, Erection and testing charges for new CT/PT including Labour charges fabrication work and crane charges, 33 kv SF6 Breaker repair servicing and testing, 33 kv isolator service alignment an...
Repairs to pump No 3
Repairs and reconditioning of pump No 3 of aligning nuts and coupled bolts of pump dismantling the motor from bed by using mechanical equipment without damaging other parts removi...
Arresting the leakages in raising main 1000 mm dia PSC & RCC P2 class pipe including excavation and cement mortar including necessary required items with lead & lift as per directed by engineer in cha...
33 kv sub station jungle cutting, providing CI pipes wherever necessary, drainage works, surfacing of station yard by 20-25 mm jelly spreading, structure painting including station fencing, testing an...
Supply of LED floodlight luminaire with pressure die cast aluminium housing body for optimal thermal dissipation. Lamp compartment comprising of anti glare clear diffuser with Injection moulded polyca...
Smart Surveillance System (CCTV)-Fixed Camera Specifications- Lens type-Bi focal auto iris with 10xdigital zoom, Mode-Day/Night, Image size-720x486 (NTSC), Streaming-High speed Weather Proof- IP 66 co...
Supply of Chain pulley block 10 Ton Capacity
Buyback of existing Transformer-
1. VOLTAMP Transformers Pvt Ltd Baroda (India)- Manufacture year 2003, 33kv/3.3kv , 1250 kVA , (Total Wight 5620 kg - weight of oil 1120 kg = Net wieght 4500 kg)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
additional Circulars for DTP.pdf
Others - Circulars • 7.10 MB
DTP-Gen 3648.docx
Tender Document • 1.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .