Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹40.4 LAccepted-AOC 34 B A HOUSE NO 253 3 SECTOR C KALERHARI CHURCH ROAD AMBALA CANTT 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹41.8 L+₹1.2 L (3.03%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 3 | L3₹43.8 L+₹3.2 L (7.81%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST BIDDER | |
| 4 | L4₹44.4 L+₹3.9 L (9.53%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L4 | Rejected-Finance OTHER THAN LOWEST BIDDER |
Tender Value
₹45 L
EMD Value
₹90,000
Closing Date
5 Mar 2020, 6:00 pmClosed
GE AF AMBALA
GE AF AMBALA
GE AF/AMB-61/2019-20 MANNING AND OPERATION OF DG SETS AND REPAIRS / REPLACEMENT OF EARTHING INFRASTRUCTURE, LIGHT FITTINGS / FIXTURES AND CONNECTED ACCESSORIES AT ZONE-A (TECHNICAL AND DOMESTIC AREAS) AF STATION AMBALA UNDER GE (AF) AMBALA
2020_MES_318643_2
GE AF/AMB-61/2019-20
Open Tender
Civil Works
Item Rate
330 days
GE AF AMBALA
AS PER TENDER DOCUMENTS
10 documents required · 10 mandatory
₹500
Yes
GE AF AMBALA
₹90,000
Yes
23 Mar 2020
19 Feb 2020
7 Mar 2020
19 Feb 2020
5 Mar 2020
21 Feb 2020
Amount
Manning & Operation of substation with 1No. DG set 160kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for GCA power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 1No. DG set 160kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for base OPs power house complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 1No. DG set 75kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for CRRW/AFNET complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation & new DSS with 2Nos. DG sets 100kVA & 160kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for 14Sqn complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 1No. DG set 400kVA by providing 01 (one) FGM, in 03 (three) shifts of 8hours each (round the clock 24hrs) x3 shifts = 3 FGMs on all days including Sundays and holidays for 27 MMPU complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Manning & Operation of substation with 1No. DG set 62.5kVA by providing 01 (one) FGM, in 02 (two) shifts of 8hours each (0800 to 1600hrs & 1600hrs to 2400hrs) = 2 FGMs on all days including Sundays and holidays for Green Field complete all as specified, detailed hereinafter and as directed by the Engineer-in-charge .
Notes for serial item Nos. 1 to 6: (i) The timings for each shift shall be as decided by the Engineer-in-charge. No claim whatsoever on this aspect is admissible (ii) 'NIL'or 'Zero' quoting of rates against any items will be treated as 'Non Bonafide'. (iii) The rate quoted shall not be less than minimum fair wages as notified by the Government of India / State Government / Local bodies / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable. In case, the rates quoted by the bidder are less than the minimum fair wages as notified by the Government of India / State Government / Local body / Labour Regulations whichever is higher including all statutory provisions such as EPF, ESI, Bonus, taxes, etc. as applicable, his tender will be treated as 'NON BONAFIDE' and will not be considered for acceptance. In such case, the lowest tender shall be determined by the lowest amount amongst valid / bonafide bids only.
(iv) The minimum wages as derivied by the Deartment including all statutory provision such as ESIC, Bonus, GST, taxes, etc. except the Contractor's profit for skilled person works out to Rs. 705/-per person per shift and for un-skilled person Rs. 552/- per person per shift (v) Increased wages including all other benefits in compliance of statutory provisions shall be paid to the workers by the Contractor. No other claim whatsoever shall be admissible on this account and the bidders shall note this aspect and quote their rates accordingly. It must be noted that in compliance of all statutory provisions, the increase will be passed over to the workers
Surface excavation not exceeding 30cm deep and averaging 15cm deep in soft / loose soil and getting out including taking out roots, shrubs etc, complete all as specified and as directed
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth for foundations, manholes, etc. or for laying cables/pipes, erecting poles, etc.not exceeding 10sqm on plan and getting out in soft / loose soil complete all as specified and as directed
Excavating in post holes (or similar holes) each not exceeding 0.5cum, returning, filling in, getting out in soft / loose soil and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm and removing surplus soil to a distance not exceeding 50m complete all as specified and as directed
Returning, filling in, including, spreading, leveling, watering and well ramming in layers not exceeding 25cm deep as in any type of soil complete all as specified and as directed
Removing excavated materials to a distance not exceeding 50m and depositing where directed at a level not exceeding 1.5m above the starting point in any type of soil including spreading in low lying area and leveling complete all as specified and as directed
M&L for fine dry river sand cushioning by laying 8cm thick layer below the cable for making soft bed and 15cm above the cable and then punning down to its consolidated thickness of 18cm after the cable is laid all as specified in SSR Part-I complete all as specified and as directed Note: Only punned thickness of sand shall be considered for measurement purposes
Supply and laying burnt bricks of sub-class 'B' designation 75 laid in trenches for cable protection complete all as specified and as directed
M&L for plain cement concrete 1:4:8 (type D-2) using 40mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed
M&L for plain cement concrete type B-1,1:3:6 (using 20mm graded stone aggregates) in copings to poles, padding, PCC bed blocks and the like including weathering, slightly rounded or chamfered angles and throating, etc. including necessary formwork complete all as specified and as directed
M&L for hard core of gauge not exceeding 63mm, deposited, spread and levelled in layers not exceeding 15cm thick, watered and rammed to a true surface, using broken stone or boulders complete all as specified and as directed
S&F in repairs cable route/path indicator made out of 300x250x3mm thick MS sheet duly rivetted and welded to 750mm long MS angle iron of size 40x40x5mm and duly embedded in PCC 1:3:6 type C-2 block of size 300x300x300mm including necessary excavation and earthwork and painting all exposed steel surfaces with two coats of synthetic enamel paint over a coat of red oxide primer and writing size and voltage of cables complete all as specified and as directed
M&L for dismantling damaged posts or struts (wood, steel or RCC) embedded in natural ground, of any section, including taking out of embedded portion and making good disturbed ground and disposing off complete all as specified and as directed
M&L for dismantling rusted / damaged fencing wire of any size / type and disposing off complete all as specified and as directed
M&L for preparing of new / old steel surfaces of fencing posts / MS flats, welded mesh, etc. over 10cm in width or girth and applying two coats of synthetic enamel paint (tint as approved) over a coat of red oxide zinc chrome primer complete all as specified and as directed
M&L for preparing of old steel surfaces of any description over 10cm in width or girth and applying two coats of aluminium paint complete all as specified and as directed
S&F mild steel hand rail, half round or other section, drilled and counter sunk for balusters, running bars, for doors, nosing to steps including embedding in concrete and screwing, etc. wind ties for roof including scruring bolts, posts / struts in fencing including cutting tops to shape, drilling holes, notching for wire, etc. flat iron fillets (for securing wire mesh, etc. including all necessary drilling bolting or rivetting, etc. and similar works conforming to Fe-290 Gde E-165 complete all as specified and as directed
S&F MS XPM (expanded metal) of weight excceding 4kg/sqm, cut to size & fixed with and including GI staples/binding wire to fencing post & shutter with FI fillets complete all as specified and as directed Note: Fencing post, shutters & fillets will be measured and paid under respective items herein
M&L for taking out 40/20mm graded/any grade stone agregates from inside of substation / fenced areas, screenig, cleaning with water and re-spreading and levelling in same areas to required thickness complete all as specified and as directed
Supplying and spreading 40mm graded crushed stone aggregates, levelling in layers not exceeding 150mm thick around transformers / LT panels, etc. at sub-stations / installations complete all as specified and as directed
Supplying and spreading 20mm graded crushed stone aggregates, levelling in layers not exceeding 150mm thick around transformers / LT panels, etc. at sub-stations / installations complete all as specified and as directed
M&L for removing vegetation of any type, including roots from surrounding areas of sub-stations, etc. by manually digging carefully and levelling the disturbed surfaces and spraying with and inlcuding Herbicide chemical (GLYPHOSATE 41% SL) with spray machines to stop further vegetation growth with all required tools / machineries, etc. complete all as specified and as directed
Supply and lay in position rubber matting, chequered sheet of size 2.0x1.0m and 19mm thick, heavy duty, conforming to relevant IS, electric shock proof suitable for 11kV installations including disposing off old / damaged matting (any type) complete all as specified and as directed
Supplying, laying / fixing, testing and commissioning of electric cable, 3.5 core 25sqmm, 1100V grade aluminium conductor XLPE insulated, galvanised steel wire / strip armoured cables conforming to IS-7098 (Part-I)-1988, stranded, XLPE insulation, PVC tape inner sheath including taking up old / unserviceable cable and brick covers and disposing off complete all as specified and as directed. Note: Excavation/earthwork, bricks, sand cushoing and GI pipe shall be measured and paid separately under respective items herein
Supply, erect in position and fixing steel tubular swaged poles with CI base plate (300x300mm and 6mm thick), finial taper plug, pole caps, bolts, nuts and screws type 410 SP-31, 9m long with detachable bracket arms including two coats of silver paint over shop coat of primer at any locations including shutting of power lines, etc. taking down of old / unserviceable PCC poles and disposing and carting off complete all as specified and as directed Note: Excavation / earthwork and PCC coping etc. will be measured and paid separately under respective items herein
S&F feeder pillar box of size 900x900x600mm, outdoor type, double door, suitable of 3 phase 415V, fabricated out of 3.15mm thick MS sheet with 4Nos. 315Amps rated aluminium busbar, coloured PVC sleeves (red, yellow, blue and black) provisioning of suitable locking arrangments, duly placed over and including angle iron (40x40x6mm) frame stand grouted in ground with PCC foundatiuon 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connection with thimbles nuts, bolts, lugs, cable glands, etc. painting all over with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, including 01No. 4P MCCB 250Amps, 25kA inter-connected with busbar and dismantling old unserviceable feeder box / panel and disposing off complete all as specified and as directed
S&F feeder pillar box of size 900x900x600mm, outdoor type, double door, suitable of 3 phase 415V, fabricated out of 3.15mm thick MS sheet with 4Nos. 500Amps rated aluminium busbar, coloured PVC sleeves (red, yellow, blue and black) provisioning of suitable locking arrangments, duly placed over and including angle iron (40x40x6mm) frame stand grouted in ground with PCC foundatiuon 1:2:4 type C1 with 20mm graded stone aggregate alongwith all necesary cable connection with thimbles nuts, bolts, lugs, cable glands, etc. painting all over with 2 coats of synthetic enamel paint (of approved tint) over a coat of red oxide zinc chrome primer, including 01No. 4P MCCB 400Amps, 35kA inter-connected with busbar and dismantling old unserviceable feeder box / panel and disposing off complete all as specified and as directed
S&F LED light fittings 90watts, input 110 to 280V, auto-shut down on high voltages, life>50000hrs, operating temperature 1 to 50oC, IP 65 protection class, street light luminaries comprising of rectangular shape pressure die cast aluminium housing with weather proof gasket for lamp and driver compartment with system wattage of 60W =10% W & rated lumens of min 5000 lumens with 120 degree view angle, the driver must be constant current type having THD<10% and power factor>0.95 with short circuit protection, open circuit protection, reverse circuit protection, high voltage protection, protection against 10kV high surges, the luminaire must have secondary optics with perfectly matched lenses for better light control and complying to IEC60598/IS10322 i with 90W LED lamp including taking down and disposing off old light fitting (any type) complete all as specified and as directed
S&F in repairs security light brackets of 40mm bore GI tubing, light grade, bent to shape required, 1.5m long fixed at position with and including flat iron clamps made of FI 50x6mm, nuts, bolts, washers etc. duly painted with two coats of synthetic enamel paint over a coat of red oride zinc chrome primer complete all as specified and as directed
S&F GI tubing 15mm bore, light grade, not less than 3m long, fixed to steel tubular / PCC poles with necessary, pole mounted fittings, fixing accessoires such as nuts, bolts, washes and 02Nos. FI (25x3mm) clamps fixed tightly including fixing in with the existing juction / terminal box and platform properly complete all as specified and as directed
S&F in repairs thermoplastic cable junction box with 02Nos. PVC gland, weather proof, IP 656/67 protection class, for outdoor installation with knock outs for cable entry of size 355x255x122mm hinged type with 4Nos aluminium bus bar of size 25x6mm and 8Nos. terminals with all required nuts, bolts, mounted on bus bars and 01No. MCB 10Amp 10kA and connecting up with existing cable and duly fixed with MS clampscmade out of FI 40x3mm thick with nuts & bolts as required complete all as specified and as directed
Supply, laying / fixing in repairs copper conductor flexible cable 2 core 2.5sqmm, PVC insulated, multi-stranded, 1100Volt grade drawing into street light pole complete all as specified and as directed
S&F in position 50mm bore GI tubing, light grade, ISI marked with fittings for cable protection laid in trenches, floors or fixed to walls with and including suitable sized clamps made from FI 40x3mm with all required nuts, bolts, washers, etc. complete all as specified and as directed
S&F in repairs galvanised iron strip of size 32x6mm buried in ground / laid in ducts / fixing along walls, etc. including necessary saddles, nuts, bolts, etc. as required complete all as specified and as directed
S&F in repairs galvanised iron strip of size 25x3mm buried in ground / laid in ducts / fixing along walls, etc. including necessary saddles, nuts, bolts, etc. as required complete all as specified and as directed
M&L for earthing with galvanised steel earth plate electode 600x600x6mm thick buried directly in ground, earth pit not less than 2.25m deep below ground level connection to and including GI earth strip of size 32x6mm to the extent of 7.5m as earth lead by means of GI bolts, nuts, etc. with provision of charcoal and salt all as per electrical plate No. 3 of SSR Part-I including water arrangement with GI pipe 20mm dia (medium grade), earth lead protection pipe 50mm madium grade with bends, elbow, etc. from earth plate to test point, excavation and earthwork in any type of soil, returning, filling, ramming and removing of soil to distance not exceeding 50m, make good to match with existing surface making PCC pit (earth chamber) having internal size 300x300x300mm and outer size 600x600x600mm with RCC reinforced cover 50mm thick and testing on completion including making test points on wall as per SSR specifications and taking down and disposing off old unserviceable earthings complete all as specified and as directed
Notes: (i) The cost of GI earth continuity conductor with GI pipe 50mm medium grade upto 7.5m is deemed to be included (ii) The earth chamber to be constructed 0.5m from edge of earth pit with necessary watering arrangement. The cost for the same is deemed to be included in above item
m/s parmod kamar
SHREE SAI LABOUR CONTRACT CO-OPERATIVE SOCIETY LTD
R D Bansal
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .