Loading…
New: tenders and results on WhatsApp
New: Find tenders, results and companies on WhatsApp, by text or voice note
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹46.9 LAccepted-AOC NO 2 GF AKSHAYRAJ APARTMENT JUBILEE CIRCLE BHUJ 370 001 | BHUJ | KACHCHH | GUJARAT | 370001 | 1 | Accepted-AOC AOC | |
| 2 | 2₹49.4 L+₹97,223 (2.01%)Rejected-Finance 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | 2 | Rejected-Finance Not L1 | |
| 3 | 3₹49.7 L+₹1.2 L (2.52%)Rejected-Finance | 3 | Rejected-Finance Not L1 | |
| 4 | 4₹56.1 L+₹7.7 L (15.8%)Rejected-Finance 33 NATIONAL CHAMBERS NEAR CITY GOLD CINEMA ASHRAM ROAD AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | 4 | Rejected-Finance Not L1 | |
| 5 | 5₹56.5 L+₹8.1 L (16.6%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTER SARU SECTION ROAD JAMNAGAR 361008 | JAMNAGAR | JAMNAGAR | GUJARAT | 361008 | 5 | Rejected-Finance Not L1 |
Tender Value
₹70 L
EMD Value
₹1.3 L
Closing Date
30 Nov 2024, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE (AF) Jamnagar
CWE (AF) Jamnagar at air force Jamnagar 1
REPAIR / MAINT TO ELECTRICAL FITTING / FIXTURES WITH ALLIED WORKS AT TECH AREA UNDER GE (AF) JAMNAGAR NO 1.
2024_MES_683057_1
81220/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Jamnagar
As per NIT
7 documents required · 7 mandatory
₹1,000
GE (AF) No 1 Jamnagar
₹1.3 L
Yes
13 Jan 2025
8 Nov 2024
2 Dec 2024
8 Nov 2024
30 Nov 2024
23 Nov 2024
Amount
Taking down carefully aluminum flame proof point wiring complete of any type (surface ERW conduit for light point, fan point, or power point complete with all fitting such as rotary switches, sockets, fan regulators etc complete and making good disturbed surfaces complete all as specified and directed.
Material & Labour for point wiring for one light point controlled by one flameproof switch, complete with 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen) cable 1100 volts grade ISI marked drawn and including mild steel ERW conduit not less than 20 mm dia, including all accessories like bend, tees, junction boxes etc. including 1.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed, FR-LSH cable as a earth wire connected to common earth dolly, etc complete all as specified and directed.
All as per item No 04 above but wiring with 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke & Halogen, cable and 2.5 Sqmm multi-stranded copper conductor PVC insulated, unsheathed fire retardant low smoke, cable as earth wire connected to common earth dolly for 15 Amps multipurpose socket outlet on independent board, controlled with one way switch complete all as specified and directed.
Supply and fix Switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed.
Supply and fix Flame proof switch socket & plug combined in LM6 cable termination box in LM6, 16A, 250V, 2P+earth, complete all as specified and directed.
Supply and fix in repairs flame proof and weather proof industrial type DBs TPN 415 Volts with and including various combination of incoming and outgoing flame proof MCBs suitable for and including (a) 01 No MCB TPN 63 Amps, 10 KA C type (incoming) (b) 06 Nos MCB SP 10 Amps 10 KA C type (c) 2 Nos MCB SP 20 Amps 10 KA C type, including necessary connection, complete all as specified and directed.
S&F in repairs OF flame proof weather proof flood light fitting suitable for & including 90 watt LED chips, flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection in cast aluminum alloy LM 79 construction, including driver, reflector, connector block, etc, and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed.
S&F in repairs OF flame proof weather proof flood light fitting suitable for & including 70 watt LED chips, flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection in cast aluminum alloy LM 79 construction, including driver, reflector, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed.
S&F in repairs OF flameproof, weather proof LED tube light fitting, type FLP-WP with LED 1 x 16 flame proof, CMRI certified recommended for gas/ vapor group of IIA & IIIB, Zone 1 & 2 and IP 65 protection including integral reflector made of aluminum alloy LM79 , with electronic driver, connector block, etc., and all accessories pre-wired and including connecting up with copper conductor cable of suitable type complete all as specified and directed.
Material & Labour for sub main wiring in repair with 2 run single core multistranded copper conductor cable of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit not less than 20 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 2.5 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified and directed. Note: 2 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment.
Material & Labour in for sub main wiring in repair with 4 run single core multistranded copper conductor cable of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH (Flame Retardant Low Smoke & Halogen), drawn through and including mild steel ERW conduit class 'B' (ISI Makes) not less than 32 mm dia with all necessary fitting and including one run single core multistranded copper conductor cable, of size 6 Sqmm, PVC insulated, unsheathed, FR-LSH as earth wire, fixed on wall / ceiling, complete all as specified and directed. Note: 4 Runs of main cable and one run earth wire with conduit will be measured as one Unit for payment
Supply and erect Prestressed concrete pole, 9.0 metres long, 102mm x 172mm at top and 102mm x 279mm at bottom, class 10, including takingdown old pole any type and removal. Note:- (a) Rate quated is inclusive of following (i) Excavation&Earthwork ,Returning filling and Removal in any strata (ii) PCC (1:3:6) type C2 as per specification (iii) Coping (1:2:4) type B1 as per specification.
Supply , installation, testing & commissioning in replacement factory made, CPRI approved, outdoor type, LT Panel board of size 900mm 900mm x 450mm , confirming to IS 5039- with IP-54 protection, made out of 3.15 mm thick CRCA sheet , 415 Volt, 3 phase , 50 HZ supply mounted on and including MS angle section 50 x 50 x 6 mm frame with front and back openable, double door with provision of locking arrangement dust & vermin proof , gasket, TPN busbar shall be insulated with colour coated heat shrinkable sleeves and shall be mounted on proper insulator, gland, welding hinges of dust proof, overall powder coated complete all as specified and directed & Consisting of the following equipments:- (i) MCCB, 4 pole, 16 KA , 100 Amps -01 No (ii) MCCB, TPN, 16 KA, 63 Amps - 02 Nos (iii) Mounting arrangement for 2 MCB for future Expansions. (iv) Power Contactor MNX75/80-01 No (v) Analog type time switch-01 (vi) Solid aluminium bus bar 200 Amp for 3 phase , 200 Amp for neutral
M&L in repair for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6.0 mm thick burried directly in ground not less than 2.25 mtrs deep below normal ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, surrounded from all sides with mixture of charcoal and common salt and electrode to galvanised iron strip 25x4mm as earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel protected by galvanised iron light grade 40 mm dia pipe and GI Pipe 20 mm light grade for water filling including 15x20 mm reducer socket funnel wire mesh, RCC cover PCC chamber pit with PCC (1:3:6) type C-2 excavation and earth work, disposal of surplus spoil, to a distance not exceeding 50 mtrs all as specified and shown on electrical plate No. 3 of 2009 (Part-I) complete all as directed. Note:- (i) Quoted rates shall be deemed to include for earth strip with protection pipe up to 7.5 M length. (ii)Black Soil to be arrange by contractor for mixing with charcoal, crystal salt , and also for fiiling balance portion of unit in layers is deemed to be included to be rate quoted. (iii) transportation charges for arrangement of black soil is deemed to be included in the rate quoted.
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 16 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed
Supply & laying XLPE insulated, PVC inner sheathed, armoured with galvanised steel strip or wire, heavy duty, LT underground cable, with aluminium conductor 1100 volt grade of size 25 Sqmm 4 core laid in trenches / duct passing through pipe / duct or fixed on pole and connecting and testing etc complete all as specified & directed (Note for item No 17 & 18 :-(i) Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid for separately. (ii) Road cutting/floor cutting /cutting holes etc in walls required for laying/fixing of cable etc shall be made good as per existing. Nothing extra shall be admissible on this account. Quoted rates shall be inclusive of the above provisions.)
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles etc, n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/loose soil alongwith disconnecting U/S XLPE cable any size and taking out including bricks/cable cover for protection, sand cushioning and stacking, removal to store for re-use or for credit, etc complete all as specified and as directed.
Excavation in trenches not exceeding 1.5 metre wide and not exceeding 1.5 metre deep for laying/taking out of cables and foundation of poles et, n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in Hard/dense soil complete all as specified and as directed.
Returning filling in including spreading leveling, watering and well ramming in layers not exc 25 cm thick using excavated soil complete all as specified and as directed.
Removing excavated soil to a distance n.exc 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and as directed.
Material and labour, sand cushioning with a layer of dry river sand, 80mm thick before laying of cable and 150mm thick (punned down to 100mm thick) after laying of cables, in trenches/ducts, complete all as specified and as directed. Note : Punned down thickness (overall 18cm), shall be considered for measurement and payment.
Supply & laying ISI marked & conforming to IS - 5820 - 1970 unreinforced precast concrete cable cover Class LV , Type I , flat size 250 mm X 150 mm X 40 mm in trenches at 10 mm gap as protection to LT UG cable all as specified and directed.
Supply and laying / fixing , GI pipe light grade 40mm dia bore for cable protection fixed to pole/wall or laid under floor/roadv /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and as directed.
Supply and laying / fixing , GI pipe light grade 50mm dia bore for cable protection fixed to pole/wall or laid under floor/roadv /pavement, including flat iron clamp, nut, bolt, wahser etc of required size and taking out old & removal, complete all as specified and as directed.
S&F of LED flood Light fitting 200 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws fixed on existing bracket & connecting, Fixed in repair, complete all as specified and directed.
S&F in replacement of LED Street Light fitting 120 Watt, system efficiency not less than 100 lumen / watt, IP65/66 protection, consisting of high / low voltage cut off, maintenance free isolated Electronic driver circuits, Low THD, PMMA grade high quality Transmittance lens, Epoxy powder coated Die Cast Aluminium housing with weather proof gasket for lamp & driver compartment, Heat resistance toughened glass fitted in cast aluminium housing with SS screws, fixed on existing bracket & connecting,Fixed in repair, complete all as specified and directed.
Supply & fix of PVC insulated, PVC sheathed, cable, with multistrandard aluminium conductor of size 2.5 Sqmm, 2 core, fixed from Junction box to street light fittings including taking down old cable.
S&F in replacement of 20 mm bore UPVC pipe of pressure rating 4 kgf/cm ² inclusive of fitting etc fixed on pole / wall with mild steel clamps made out of MS Flat 25 x 6mm including, nuts, bolts at the interval of 1metre complete including two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Supply and fixing in repair copper earth strip of size 20 x 3 mm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminals to test point terminal including taking down old strip all as directed by Engr-in-charge. Note : Epoxy insulator will be measured and paid separately under respective items of this Schedule.
Supply and fix in repair 25 mm size epoxy type insulator suitable for fixing earthing strip including screw etc all as directed by Engr-in-charge
S&F in repair of Sheet moulding compound (SMC) junction box of size 340 mm x 160 mm x 90mm, or higher comprising three phase aluminium bus bar and fixed on pole with mild steel clamps, nuts and bolts complete.
Supply and fixing in repairs TAC Galvanised iron earth wire of size 4sqmm with epoxy insulators and fixing screws etc for earth continuity conductors to test point terminals to test point terminal including taking down old strip all as directed by Engr-in-charge. Note : Epoxy insulator will be measured and paid separately under respective items of this Schedule.
S&F Air termination, Star pointed copper rod 14 mm dia and 500 mm long with copper Air Rod fixed in position on pole complete with clamp and nut bolts, fixed in repairs all as specified and directed
SURESH ELECTRICALS (BID ID -3177159)
S t modi (BID ID -3177856)
shree chamunda enterprise (BID ID -3177382)
M/s SK Traders (BID ID -3172995)
jagdish machinery stores (BID ID -3177541)
Nitesh Enterprise (BID ID -3177699)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .