| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹30.5 LAccepted-AOC BELOW SLAUGHTER HOUSE KRISHNA NAGER SHIMLA | SHIMLA | SHIMLA | HIMACHAL PRADESH | L1 | Accepted-AOC accept | |
| 2 | L2₹31.2 L+₹75,435.72 (2.47%)Rejected-AOC | L2 | Rejected-AOC accept | |
| 3 | L3₹33.0 L+₹2.5 L (8.22%)Rejected-AOC VILLAGE P O MANSIMBLE TEHSIL PALAMPUR DISTRICT KANGRA HP | KANGRA | HIMACHAL PRADESH | 175013 | L3 | Rejected-AOC accept | |
| 4 | L4₹36.2 L+₹5.7 L (18.8%)Rejected-AOC | L4 | Rejected-AOC accept |
Tender Value
₹17.5 L
EMD Value
₹33,700
Closing Date
23 Feb 2021, 5:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Executive Engineer JSV Division Thural
O/O The Executive Engineer JSV Division Thural
Providing LWSS to PC habitation to Gharana khas , Alsa Badhrer Tamloh etc covered Under ( Jal Jeevan Mission ) LWSS Lahru Bhanwar in Tehsil Palampur Distt Kangra.( H.P.)
2021_HPIPH_44436_1
THL-KNG05-729 (18492-18545 dated 16.02.2021)
Open Tender
Civil Works - Water Works
Item Wise
180 days
Providing LWSS to PC habitation to Gharana khas
Please refer Tender documents.
10 documents required · 10 mandatory
₹400
₹33,700
Yes
12 Apr 2021
16 Feb 2021
24 Feb 2021
16 Feb 2021
23 Feb 2021
16 Feb 2021
120 days
Amount
Excavation in foundation trenches etc.( for pipes and pits)up to all depths in all kind of soil such , as pick work, jumper work saturated soil including bailing or pumping out water, blasting soft/hard rock or chiselling soft /hard rock where blasting is prohibited in all leads & lifts including triming & dressing of sides levelling of beds to correct grade including shorting struttering planking timbering and dewatering where ever required stacking usable/unusable material / soil separately and after laying jointing and testing of pipes returning the usable soil in trenches in 15cm layers including consolidating of such deposited layer by ramming & watering & then disposing of all surplus excavated earth as directed with in all leads & lifts including restoration of unmetalled surfaces to its original condition & including cost of a diversion for traffic night signals,fixing caution boards crossing over trenches for access to houses fencing etc. as per direction of Engineer-in-Charge with in all leads and lifts.
Laying, jointing & testing of GI pipe with circumfrential butt welded joints by electrical arc welding ( welding thickness shall be equal to pipe wall thickness) steel flanged pipes after every 100 mtr of pipe of following diameter Conforming to IS 1239-1990 (Part-II), having wall thickness as specified below capable of withstanding required test pressure, including manufacturing and febrication of reducers/ tapers , all short pieces, etc. as per site requirement made from parent tubes . The laying of pipe shall also include flanged joints duly welded in three layers (Two inner & one outer), where ever required as per direction of the Engineer-in-charge (Earth work in trenches and the cost of providing flanges i/c nut & bolts, gasket will be measured and paid for separately) and all operations such as cutting, welding, jointing, fabrication of tees i.e. lowering and laying in excavated trench to ensure required level including flushing, cleaning and hydraulic testing complete in all respects to the entire satisfaction of the Engineer in charge. The welding electrodes shall be as per IS 814 of Advani Oerlikon/ L&T or ISI marked make. The damaged portion of the pipes and all the specials ( If damaged during laying & jointing operation of pipe) made form the parent tube shall be provided anticorrosive treatment by applying two coats of anticorrosive bituminous paint over a priming coat as per AWWA specifications C-203-1978. The rates also includes entire carriage of material, flushing, cleaning & hydraulic testing, D.P. test of butt welded joints complete in all respect and to the best satisfaction & direction of Engineer in charge with in all leads and lifts.
2nd stage G.I. ( M. Class) pipe 80mm dia with wall thickness 4.80 mm of , (FT-28) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 0 to 300 = 300 Rmt
2nd stage G.I. ( M. Class) pipe 80mm dia with wall thickness 4.80 mm of , (FT-17) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 300 to 990 = 690 Rmt
2nd stage G.I. ( M. Class) pipe 80mm dia with wall thickness 4.80 mm of , (FT-5) outer dia 89.50 mm , at every 100 mtr pipe flanged from RD 990 to 1650 = 660 Rmt
Providing and laying cement concrete 1:3:6(1cement:3 sand:6 graded stone aggregate 40mm nominal size and curing complete excluding the cost of form work in foundation and plinth with in all leads and lifts as per direction of Engineer-in-Charge with in all leads and lifts
Providing form work with steel plated 3.15mm thick welded with angle iron in frame 30x30x5mm, so as to give a fair finish including centring,shuttering,strutting and propping etc. with wooden battens and ballies height of propping and centering below supporting floor to ceiling not exceeding 4 meters and removal of the same for insitu-reinforced concrete and plain concrete work with in all leads & lift.Vertical surfaces such as walls(any thickness) partitions and the like including attached pilasters, buttresses, plinth and string courses and the like complete in all respect as per direction and to the entire satisfaction of the Engineer-in-charge.
Providing and laying cement concrete 1:5:10 ( 1 cement: 5 sand: 10 graded stone aggregate 40mm nominal size) with 15% plum and curing complete excluding cost of from work in retaining walls/Breast walls, the size of plums shall usually be 150mm. To 300mm. as per H.P.P.W.D. Specification with in all leads and lifts as per direction of Engineer-in-Charge with in all leads and lifts
Boulder filling behind retaining Walls tightly hand packed ramming and watering as per direction of Engineer-in-Charge with in all leads and lifts.
Providing and laying cement concrete work 1:2:4 (1 cement: 2 sand: 4 graded stone aggregate 20 mm nominal size) and curing complete excluding cost of from work and reinforcement for reinforced concrete work in : Suspended floor roofs, landing and shelves and their support balconies, beams, girders, bressumers and contilever upto floor two level as per direction and to the entire satisfaction of Engineer-in-Charge
Providing, Laying mild or tor steel reinforcement for RCC. Work including bending binding and placing in position complete upto floor two level Tor steel with in all leads and lifts.
Stage-1st , Supply of submersible pumping set of (KSB /Kalama/Kirloskar/Johnston/Cromption/BS) make conforming to BIS; 8034-1976 latest suitable for lifting Raw water (latest with uptodate ammendments) fitted with bronze impellers/suitable alloy directly coupled to squirrell case electric induction motor of same make as (manufacurer standard) conforming to BIS; 9283-1979 (latest with uptodate ammendments) and totally water proof for submersible duty, isolated from the pump by intermediate casing with double mechanical seal in oil chamber, grease packed lubricated bearings & provided with stainless steel thrust bearing plate to with stand vertical loads with minimum wear & tear. It should also be fitted with a device to take up expansion of water with the heating of motor including water level guard,errection clamps,cable clips & depth gauge etc. The pump shall be suitable for operation on data given below:-2 sets of 5.00 HP each
Total Head,30.10 Mtrs,Discharge required from each pump.4.52 LPS for each pump ( One Will act as stand by)No. of pump required,2.00 Nos. One act as stand by,Location of the site of installation of machinery.,The site is located at a distance of 35 Kmts from Palampur.,The Altitude of installation.The altitude of place is 700 mtrs above MSL,Type of current.AC Three phase supply with,Rate Voltage,415+ 10%,Type of water and its source,Clear water,Charactristics of water.a)Ambient Temperature dig.c,20 dig. C,b)Turbidity NTU, NTU,c)Hardness260Mg/Ltrs(as CaCO3),d) PH 7.5,e)total solid Mg /Ltrs,f)Other,Depth of S/Well,4 mtrs,LWL in S/ well, mtrs.,Dia of Bore,Maz draw down,Static water level in S/Well, mtrs,Center line level of Pump ,549.30 mtrs,Discharge level of highest point,570.00 mtrs,Static head in Mrs,20.70mtrs.Length of R/Main (Including Column Assembly),250 mtrs.,Dia of Rising main,80 MM,No of working hours per day,8 Hours,Limit of pump operation.,(-) 15 % (+) 10% of total head,R.P.M. of pumping set.,2900 RPM ( or to be specified by the tenderer),Test run.8 Hours continueously for 7 days
Supply , installation, testing and commissioning of PLC (Programmable Logic Controller) based Fully Automatic LT Panel for submeresible pump made out of 16 Gauge sheet powder coated dust and veremin proof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump automatically as per site requirement along with sluice valve automatically as per design timing which can be acted as and when required one at a time or together as per requirement through PCL panel (CPRI approved , with 50 KA Short Circuit and IP-55 protection duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4 mm at bottom inside panel 1 No. board with two earth tereminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in gray colour all as spcified & directed, Make of panel board : dvepl / aspl / tricolite. The pannel board should also have following items ( i to xviii).
PLC (Programmable Logic Controller) 1.00 Nos
ICTP switch with HRC fuses L&T / Standard / Havells make & having capacity 30 % extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.1.00 Nos
MCB /MCCB suitable capacity of Schneider/Siemens/ABB make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.1.00 Nos
Y-D starter of suitable capacity for submersible pump Make - L&T / ABB/ Schneider.1.00 Nos
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.1.00 Set
Star delta timer.1.00 Nos
Single phase parventer of reputed make Minillic / L & T / Standard & Suitable capacity.1.00 Nos
Automatic Phase Sequnce Corrector with prevention against, phase revarsal protection, under / over load protection Make ABB/ L&T / Siemens/GIC.1.00 Nos
Control MCB 6A -SP.1.00 Nos
On / Off indicator and push button.set of 1 each.LS
Control and power wiring.1.00 Nos
Power capacitor of suitable capacity.LS
Control terminal, Bus Bar, i.e.Bolt, insulator, etc.1.00 Nos
LED 5 Watt.1.00 Nos
Cooling fan 230 VAC.1.00 Nos
Hour run Meter.1.00 Nos
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast Iron double flanged sluice valve 80 mm dia class PN1.6 confirming to BIS-780-1984 (to be provided on R/main side) capable of with standing nominal seat test pressure of 16 kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast Iron double flanged swing check type reflux valve 80 dia class PN 1.6 vconfirming to BS 5312-1984 having bye pass arrangement (to be provided on R/main side) and shall be suitable for withstanding nominal seat pressure of 16 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/ Grandlay/ Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type, size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 2.5 mm^2 ( From HPSEB Meter to Switch &Starter).
On motor side 3 core flat joint less copper cable of size 2.5 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses.
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/Laying Column assembly of G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. Column assembly =80 mm dia G.I.flanged pipe(medium grade) NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Errection of all equipments i/c cost of tees, bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-2nd, Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.2 Sets,20 HP Each (2x 20 HP= 40 HP)
Total Head,174.13 Mtrs.,Discharge required from each pump.4.52lps,No. of pump required,2.00 Set (One act as stand by)Location of the site of installation of machinery,The site is located at a distance of 35 Km from Palampur.The altitude of installation.700 MSL.Type of current.AC three phase supply with freqduency of 75cycle per second.Rate Voltage,415V + 10%,Type of water and its source,Clear water.,Shaft level,557.6,Level of discharge point,689.78,Static Head,132.18,Charactristics of water.a)Ambient Temperature dig.c,b)Turbidity NTU,c)Hardness260Mg/Ltrs(as CaCO3),d) PH 7.5,e)total solid Mg /Ltrs,f)Other,Depth of well assembly,No. of working hours per day,8.00Hours.,Length of Rising main,1650 Rmts.Dia of Rising main,80 mm,Limit of pump operation.In the completem Range of (-)75% .,R.P.M. of pumping set.2900 RPM (or to be specified by the tenderer).,Test run.,8 Hours contineously for 7 days.
Supply , installation, testing and commissioning of PLC (Programmable Logic Controller) based Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin prof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump automatically as per site requirement along with acctuator sluice valve automatically as per design timing which can be acted as and when required one at a time or together as per requirement through PCL panel (CPRI approved , with 50 KA Short Circuit and IP-55 protection duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4 mm at bottom inside panel board with two earth tereminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in gray colour all as spcified & directed, Make of panel board : dvepl / aspl / tricolite. The pannel board should also have following items ( i to xviii).
PLC (Programmable Logic Controller)1.00 Nos
ICTP switch with HRC fuses L&T / Standard / Havells make & having capacity 30 % extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.1.00 Nos
MCB /MCCB suitable capacity of Schneider/Siemens/ABB make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.1.00 Nos
Y-D starter of suitable capacity for centrifugal pump Make - L&T / ABB/ Schneider.1.00 Nos
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.1.00 Set
Star delta timer.1.00 Nos
Single phase parventer of reputed make Minillic / L & T / Standard & Suitable capacity.1.00 Nos
Automatic Phase Sequnce Corrector with prevention against, phase revarsal protection, under / over load protection Make ABB/ L&T / Siemens/GIC.1.00 Nos
Control MCB 6A -SP.2.00 Nos
On / Off indicator and push button.set of 2 each.
Control and power wiring.LS
Power capacitor of suitable capacity.1.00 Nos
Control terminal, Bus Bar, i.e.Bolt, insulator, etc.LS
LED 5 Watt.1.00 Nos
Cooling fan 230 VAC.1.00 Nos
Hour run Meter.1.00 Nos
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast steel double flanged accutated sluice valve of class ASA-150 confirming to BIS-1414 (API-600) (to be provided on delivery side) of equal size to one dia more than the dia of delivery of pump and capable of with standing nominal seat test pressure of 21 kg/cm².
NOTE:-The Cast steel sluice valve shall conform to BIS:780-1984 for 50 to 300mm dia & BIS:2906-1984 for 350 to 1200mm dia ( latest edition). However if seat pressure exceeds the limits prescribed in above mentioned BIS, then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/cm² or class ASA-300 for seat pressure 52 Kg/cm² as per BS 1414 (API 600) .
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on delivery side) of size one step higher than the delivery size of pump and shall be suitable for withstanding nominal seat pressure of 2kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on Rising main) of 80 mm and shall be suitable for withstanding nominal seat pressure of 21 kg/cm².
NOTE:- The Cast steel reflux valve shall conform to BIS: 5312-1984- Part-I ( latest edition). However if the seat pressure exceeds the limits prescribed in BIS 5312 then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/cm² or class ASA-300 for seat pressure 21 Kg/cm² as per BS 1868 (API 600)
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I double flanged sluice valve class PN-1.6 confirming to BIS 780-1984 to be provided on Suction side of size one dia higher then the suctrion size of pump capable of withstanding nominal seat pressure of 10.20 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 10 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 4 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer.)
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe XXX mm dia = to be specified by the Tenderer
Delivery pipe XXX mm dia = to be specified by the Tenderer
Common header = XXX mm dia
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries).Note. The strip size shall be 20x3 upto 18.5 KW . 25x3 for 18.5 to 37 KW to 55 KW and 32x5 beyond 55 KW.
Errection of all equipments including cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Stage-3rd,Supply of horizontal spindle,horizontal/radial split casing and suction (backpull out arrangement) single/ double / multistage centrifugal pumps or combination of pumps in series /parallel of KSB / Mather & Platt/ Jyoti /Kirloskar /BE /Maxflow/ Beaconweir Sabar make conforming to BIS: 1520-1980 (latestwith upto date ammendments) read with BIS: 9137-1978 (latest edition) suitable for lifting water of under mentioned charactristics with impellers of bronze/suitable alloy, priming funnels,casing ring & shaft sleeves of bronze/ suitable alloy, shaft of sutable steel grade with cast iron casing coupled directly through a flexible coupling on a common C.I. / Cast steel base plate (base plate to be from the principle manufacturer of pumping set) to slippering/squirrel cage screen protected drip proof electric induction motor of Kirlokar /NGEF/Crompton / Siemen /Jyoti /BHEL /GEC /ABB conforming to BIS: 325-1978 read read with BIS: 900-1968 (latest with upto date ammendments) It should include the cost of bearings, nuts & bolts,painting etc. and shall be suitable for operation as per data given below.2 Sets,20 HP Each (2x 20 HP= 40 HP)
Total Head,153.53 Mtrs.,Discharge required from each pump.,4.52lps,No. of pump required,2.00 Set (One act as stand by),Location of the site of installation of machinery,The site is located at a distance of 35 Km from Palampur.The altitude of installation.700 MSL.,Type of current.AC three phase supply with freqduency of 75cycle per second.,Rate Voltage,415V + 10%,Type of water and its source,Clear water.Shaft level,686.28,Level of discharge point,795.28,Static Head,109.49,Charactristics of water.,a)Ambient Temperature dig.c,b)Turbidity NTU,c)Hardness260Mg/Ltrs(as CaCO3),d) PH 7.5,e)total solid Mg /Ltrs,f)Other,Depth of well assembly,No. of working hours per day,8.00Hours.,Length of Rising main,1740Rmts.,Dia of Rising main,80 mm,Limit of pump operation.,In the completem Range of (-)75% .,R.P.M. of pumping set.,2900 RPM (or to be specified by the tenderer).,Test run.8 Hours contineously for 7 days.
Supply , installation, testing and commissioning of PLC (Programmable Logic Controller) based Fully Automatic LT Panel for centrifugal pump made out of 16 Gauge sheet powder coated dust and veremin prof wall mounted and front opering door type switch board with copper insulated wiring suitable to operate 2 nos. pump automatically as per site requirement along with acctuator sluice valve automatically as per design timing which can be acted as and when required one at a time or together as per requirement through PCL panel (CPRI approved , with 50 KA Short Circuit and IP-55 protection duly insulated with heat shrinkable sleeve as per colour, supported on epoxy insulator 01 set, common earth bus of 25mm x 4 mm at bottom inside panel board with two earth tereminal out side panel board, cable alley cable gland with independent plate at bottom and complete panel board painted with powder coating in gray colour all as spcified & directed, Make of panel board : dvepl / aspl / tricolite. The pannel board should also have following items ( i to xviii).
PLC (Programmable Logic Controller)1.00 Nos
ICTP switch with HRC fuses L&T / Standard / Havells make & having capacity 30 % extra of the operational rating of motor as per BIS 4064-1978 with upto date ammendments immediately after the power meter of HPSEB.1.00 Nos
MCB /MCCB suitable capacity of Schneider/Siemens/ABB make on the coming feeder for pumping set confirming to BIS 2516-1985 ( Latest edition) with neutral linked under voltage release.1.00 Nos
Y-D starter of suitable capacity for centrifugal pump Make - L&T / ABB/ Schneider.1.00 Nos
Three phase indicating lamps complete with logged switches for individual motors conforming to BIS 3452 ( Part I & II ) latest with upto date ammendments.1.00 Sets
Star delta timer.1.00 Nos
Single phase parventer of reputed make Minillic / L & T / Standard & Suitable capacity.1.00 Nos
Automatic Phase Sequnce Corrector with prevention against, phase revarsal protection, under / over load protection Make ABB/ L&T / Siemens/GIC.1.00 Nos
Control MCB 6A -SP.2.00 Nos
On / Off indicator and push button.set of 2 each.
Control and power wiring.LS
Power capacitor of suitable capacity.1.00 Nos
Control terminal, Bus Bar, i.e.Bolt, insulator, etc.LS
LED 5 Watt.1.00 Nos
Cooling fan 230 VAC.1.00 Nos
Hour run Meter.1.00 Nos
Supply of Kirloskar/Kilburn /IVC/Fouress/Gled/BHEL/ Leader make Cast steel double flanged accutated sluice valve of class ASA-150 confirming to BIS-1414 (API-600) (to be provided on delivery side) of equal size to one dia more than the dia of delivery of pump and capable of with standing nominal seat test pressure of 21 kg/cm².
NOTE:-The Cast steel sluice valve shall conform to BIS:780-1984 for 50 to 300mm dia & BIS:2906-1984 for 350 to 1200mm dia ( latest edition). However if seat pressure exceeds the limits prescribed in above mentioned BIS, then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/cm² or class ASA-300 for seat pressure 52 Kg/cm² as per BS 1414 (API 600) .
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on delivery side) of size one step higher than the delivery size of pump and shall be suitable for withstanding nominal seat pressure of 2kg/cm².
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make Cast steel double flanged swing check type reflux valve having bypass arrangement of class ASA-300 confirming to BS 1868(API-600) (latest edition)to be provided on Rising main) of 80 mm and shall be suitable for withstanding nominal seat pressure of 21 kg/cm².
NOTE:- The Cast steel reflux valve shall conform to BIS: 5312-1984- Part-I ( latest edition). However if the seat pressure exceeds the limits prescribed in BIS 5312 then it shall be of cast steel conforming to class ASA-150 for seat pressure upto 21 Kg/cm² or class ASA-300 for seat pressure 21 Kg/cm² as per BS 1868 (API 600)
Supply of Kirloskar/ Kilburn/IVC/Fouress /Gled/BHEL/Leader make C.I double flanged sluice valve class PN-1.6 confirming to BIS 780-1984 to be provided on Suction side of size one dia higher then the suctrion size of pump capable of withstanding nominal seat pressure of 10.20 kg/cm².
Providing & laying PVC insulated jointless, flat water proof copper cable of Siemens/Finolex/Grandlay/Gloster make conforming to BIS:1554 (Part I) -1988 or latest with up to date ammendments of suitable size for the pump sets offered(one cable carrying all three phases) including all other electrical equipment /accessories such as thimbles ,flexible pipe, solder, nuts & bolts cable glands etc. laid in pipes or trenches under floor. The type,size & make will be subject to approval of HPSEB authorities.In case of non acceptance by HPSEB authorities it shall have to be replaced by the tenderer free of cost.
On supply side of 3½ core coper cable 10 mm^2 ( From HPSEB Meter to Switch & Starter).
On motor side 3 core flat joint less copper cable of size 4 mm^2 ( From Switch & Starter to Motor) pump installed in the bore.
Supply & errection of floor/wall mounted power shunt capacitor conforming to BIS 2834-1986 latest with upto date ammendments of GEC/Siemen/ Havells L&T make to raise the prevailing power factor at site to 0.95 for direct connection to induction motor individually of requirement KVAR according to BHP of motor offered including cable Siemens/Gloster/ICC make from busbar chamber to capacitor & also including Standard/ L&T/Kilburn/Indo asian make ICTP switches conforming to BIS 4064- 4064-1978 or latest with HRC fuses. (range to be specified by the tenderer.)
Supply of standarad make 80 mm dia circular/square dial pressure gauge of suitable range Fiebeg/Bourden/ Precision make with all accessories such as stop cock,copper tubing etc. conforming to BIS 3624-1987 latest with up to date ammendments.
P/L G.I./MSERW pipe considering site requirements and having appropriate size in accordance with the delivery size of pumping set . The pipe shall conform to relevant BIS codes & capable of with standing the feild test pressure equal to 1.5 times the operating pressure including all type of fittings such as bends, tapers/ reducers, flanges, rubber gaskets 3mmthick, nuts & bolts and any other fitting required at site and work shall be to the entire satisfaction of Engineer-in-Charge. The pipe material shall conform to relevant BIS Code and capable of with standing FTP equal to 1.5 times the operating pressure the complete arrangement shall compromise of
Suction Pipe XXX mm dia = to be specified by the Tenderer
Delivery pipe XXX mm dia = to be specified by the Tenderer
Common header = XXX mm dia
NOTE:- Actual laying to be done as per final drawings to be approved by the Engineer in charge
Providing and lying double loop earthing with coper plate 600x600 x3 thick electrode and copper strip of 25x3 complete including providing of material such as charcoal, common salt, GI pipes, thimbles, nuts & bolts, digging of pits, Copper /GI wire/ Strips of required capacity conforming to BIS 8034-1978 latest with upto date ammendments for above motor & other electriacl equipments including all civil works. (for both machineries).Note. The strip size shall be 20x3 upto 18.5 KW . 25x3 for 18.5 to 37 KW to 55 KW and 32x5 beyond 55 KW.
Errection of all equipments including cost of tees,bends tapers & any other fittings required as per site conditions & as per directions of Engineer-in-Charge.
Bharat Engg and Suppliers
SANJAY SAINI
Sanjeev
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .