Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.3 LAccepted-AOC 1 SADHANA SOCIETY DEV BAUG DEVBAUG BHAVNAGAR GUJARAT 364001 | BHAVNAGAR | GUJARAT | 364001 | L1 | Accepted-AOC M/S Krishna Construction Company is the Lowest Bidder, hence accepted | |
| 2 | L2₹17.9 L+₹2.3 L (14.5%)Rejected-Finance 00 BEHIND COURT PHALODI NAI SARAK PHALODI JODHPUR RAJASTHAN 342301 UDYAM RJ 22 0048153 | JODHPUR | RAJASTHAN | 342301 | L2 | Rejected-Finance Not Lowest Bidder, Hence rejected | |
| 3 | L3₹18.0 L+₹2.3 L (14.9%)Rejected-Finance 77 KAILASH PURI BIKANER RAJ C 15 SWC JAIPUR | BIKANER | RAJASTHAN | 331801 | L3 | Rejected-Finance Not Lowest Bidder, Hence rejected |
| Sl No | Description | Qty | Unit | KRISHNA CONSTRUCTION COMPANY L1 | M/S SOLANKI GENERAL SUPPLIERS L3 | Mahaveer Traders L2 |
|---|---|---|---|---|---|---|
| 1.00 | M&L for repair / servicing of existing UPS panel incuding dismantling electric connection and cleaning of realy junction point, connection & testing of UPS panel relay including replacement & U/S part as 20 KVA & 30 KVA complete all as specified and directed.
Note :-(a) Minor item / spares parts shall be measured and paid under respective item of schedule as supply only. | 6 | EACH JOB | 7,000 ₹42,000 Lowest | 27,747 ₹1,66,482 | 17,000 ₹1,02,000 |
| 2.00 | M&L for repair / servicing of existing special power supply system incuding dismantling electric connection and cleaning of realy junction point, connection & testing of SPS panel relay including replacement &U/S part of 3 KVA complete all as specified and directed.
Note :- a) Minor item / spares parts shall be measured and paid under respective item of schedule as supply only. | 2 | EACH JOB | 5,000 ₹10,000 | 4,747 ₹9,494 | 2,450 ₹4,900 Lowest |
| 3.00 | Supply only 3 phase DSP suitable for 20 KVA capacity UPS complete all as specified and directed. | 3 | EACH | 4,000 ₹12,000 Lowest | 5,742 ₹17,226 | 5,800 ₹17,400 |
| 4.00 | Supply only IGBT 300/1200 ISP socket suitable for 20 KVA capacity UPS complete all as specified and directed. | 3 | EACH | 5,000 ₹15,000 | 4,747 ₹14,241 Lowest | 5,500 ₹16,500 |
| 5.00 | Supply only IGBT Driver card suitable for 20 KVA capacity UPS complete all as specified and directed. | 3 | EACH | 4,000 ₹12,000 Lowest | 5,747 ₹17,241 | 5,200 ₹15,600 |
| 6.00 | Supply only 3 phase chager card suitable for 20 KVA capacity UPS complete all as specified and directed. | 3 | EACH | 3,500 ₹10,500 Lowest | 3,747 ₹11,241 | 6,000 ₹18,000 |
| 7.00 | Supply only 99/6 SCR Diode suitable for 20 KVA capacity UPS complete all as specified and directed. | 3 | EACH | 750 ₹2,250 Lowest | 1,147 ₹3,441 | 1,500 ₹4,500 |
| 8.00 | Supply only 20'' x4'' Display suitable for 20 KVA capacity UPS complete all as specified and directed. | 3 | EACH | 2,000 ₹6,000 Lowest | 5,147 ₹15,441 | 6,800 ₹20,400 |
| 9.00 | Supply only 200/1200 IGBT II out going suitable for 20 KVA capacity UPS complete all as specified and directed. | 2 | EACH | 2,000 ₹4,000 Lowest | 3,747 ₹7,494 | 4,200 ₹8,400 |
| 10.00 | Supply only IN PUT sensing PCB 3 phase suitable 20 KVA capacity UPS complete all as specified and directed. | 2 | EACH | 4,000 ₹8,000 Lowest | 4,747 ₹9,494 | 4,950 ₹9,900 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
6 Nov 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Shri Nitish Pathak,EE
GE(AF) Phalodi PIN-342301
REPAIR/MAINT OF MECH LAUNDARY, UPS, SPL POWER SUPPLY SYSTEM AND RELATED CONNECTED ITEMS AT AF STN PHALODI
2025_MES_735451_1
8740/A/E8
Open Tender
Civil Works
Item Rate
180 days
Air Force Station Phalodi
As per tender documents
7 documents required · 7 mandatory
₹500
GE(AF) Phalodi
₹40,000
Yes
9 Jan 2026
16 Oct 2025
13 Nov 2025
16 Oct 2025
6 Nov 2025
30 Oct 2025
Amount
M&L for repair / servicing of existing UPS panel incuding dismantling electric connection and cleaning of realy junction point, connection & testing of UPS panel relay including replacement & U/S part as 20 KVA & 30 KVA complete all as specified and directed. Note :-(a) Minor item / spares parts shall be measured and paid under respective item of schedule as supply only.
M&L for repair / servicing of existing special power supply system incuding dismantling electric connection and cleaning of realy junction point, connection & testing of SPS panel relay including replacement &U/S part of 3 KVA complete all as specified and directed. Note :- a) Minor item / spares parts shall be measured and paid under respective item of schedule as supply only.
Supply only 3 phase DSP suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only IGBT 300/1200 ISP socket suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only IGBT Driver card suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only 3 phase chager card suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only 99/6 SCR Diode suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only 20'' x4'' Display suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only 200/1200 IGBT II out going suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only IN PUT sensing PCB 3 phase suitable 20 KVA capacity UPS complete all as specified and directed.
Supply only out put sensing PCB 3 phase 20 KVA capacity UPS complete all as specified and directed.
Supply only HRC fuse with base 100 Amp soitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only 20'' x 4'' Display Harness suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only DC to AC power card suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only main card suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only Battery charging card suitable for 20 KVA capacity UPS complete all as specified and directed.
Supply only 12 Volt , 42 Ah battery complete all as specified and directed.
Supply only 3 phase DSP suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only IGBT 300/1200 ISP socket suitable for 30 KVA capacity UPS complete
Supply only IGBT driver card suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only 3 phase charger card suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only 99/6 SCR Diode suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only 20'' X 4'' Display suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only 200/1200 IGBT II out going suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only INPUT sensing PCB 3 phase suitable for 30 kva capacity UPS complete all as specified and directed.
Supply only out put sensing PCB 3 phase suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only HRC fuse with base 100 Amp suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only 20''x 4'' Display harness suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only DC to ac powercard suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only main card suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only Battery charging card suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only 9'' Fan suitable for 30 KVA capacity UPS complete all as specified and directed.
Supply only Battery 12 Volt 65 Ah complete all as specified and directed.
S&F in repair of existing contactor capacitor duty type 3 pole AC of capacity having coil voltage 250 volt up to suitable for 20 KVAR along with 1 NO + 1 NC auxilary contact complete all as specified and directed.
S&F in repair of existing contactor capaciter duty type 3 pole AC of capacity having coil voltage 250 volt up to suitable 25 KVAR along with 1 NO + 1 NC auxilary contact complete all as specified and directed.
S&F in repair of Battery lead for connection of batteries with two side suitable copper lux complete all as specified and directed.
S&F in replacement of potentiometer of capacity 2.5 K 1 Watt suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of capacitor of 2200 mfd 450 Volt DC suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of capacitor of 4 mfd 450 Volt AC suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of capacitor of 0.1 mfd 1000 Volt AC suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of capacitor of 330 mfd 450 Volt DC suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of relay 12 Volt DC 1 C/O 10 Amp PRMT Relay 4 in parallel suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of HRC fuse of capacity 32 Amp suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of Mini Glass fuse of capacity 500 mA suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of fan 120 mm HBT suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of Rectifier driver Card 8400-CH24B suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of Rectifier Control Card 8400-CH26A suitable for 3 KVA capacity SPS complete
S&F in replacement of Low Voltage DC-DC Card 8500-248 suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of 2P Toneluck Switch suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of IGBT Driver card 8500-179CX6 suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of Device Over card 8500-250 Amp suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of hooter PCB 8500-139 suitable for 3 KVA capacity SPS complete all as specified and directed.
S&F in replacement of 3TF32 Contractor suitable for 3 KVA capacity SPS complete all as specified and directed.
Disconnecting the electric supply by authorised dealer from existing Washing Machine panel, and dismantling / taking down Washing Machine Make - STEFAB and open up for examination capacity by loosening the coupling, foundation nut, bolt & washers, Fan belt, tensioner pulley,Testing & Checking of Heating instruments,Spinner,Automatic timer kit,Temp and level control, AC / DC wiring etc. taking out grease cleaning, Washing Machine with suitable instrument and reassembling the Washing Machine after replacement of defective/unserviceable parts viz bearing, Heating coil, coupling & foundation nuts, bolts, wasers etc. of existing make,size and capacity including changing of minar parts & proving fresh grease / Oil, making the leak proof by fixing the suitable gaskit/washer etc. including refixing and testing complete all as specified and directed NOTE:-(i) Replacement of defective Minor parts and as specified in the description shall be deemed to be include in the unit quoted rates.
Disconnecting the electric supply by authorised dealer from existing Drying Tumbler panel and dismantling/ taking down Drying Tumbler Make - STEFAB and open up for examination of Engr-in-charge of 60 Kg capacity by loosening the coupling, foundation nut, bolt& washers,Fan belt, tensioner pulley,Testing & Checking of AC & DC wiring etc. taking out grease cleaning the complete drying tumbler with suitable instrument and reassembling the drying tumbler after replacement of defective/unserviceable parts viz bearing, oil seal, coupling & foundation nuts, bolts, wasers etc. of existing make,size,and capacity including changing of minar parts & proving fresh grease, making the leak proof by fixing the suitable gaskit/washer etc. including refixing and testing on completion complete all as specified and directed NOTE:- (i) Replacement of defective Minor parts and as specified in the description shall be deemed to be include in the unit quoted rates.
Material & labour for General Servicing by authorised dealer Hydro Extractor of make STEFAB and cheaking of balancing, automatic injection break of capacity 25 Kg etc including refixing and testing on completion complete all as specified and directed. NOTE:- Replacement of defective Miner parts shall be deemed to be included in the unit quoted rate.
Material & labour for General Servicing by authorised dealer, Flat Bed Press size:1500x750mm Pneumaticlly operated of Make : STEFAB, testing & repair moisture suction,auto time release head,Rocker arms, Air cylinder, Rocker arms ball bearing ,Balancing springs,Centrifugal suction blower ,time setting of pressing & stop,Digital timer & temerature etc.including refixing and testing on completion complete all as specified and directed. NOTE:- Replacement of defective Minor parts shall be deemed to be included in the unit quoted rate.
S&F in replacement metal plug & triple pole socket, one triple pole MCB 415 Volts ,63 Amp, three pin earth encolsure, earth plug with socket complete all as specified and directed.
S&F in replacement metal plug,socket with MCB, steel enclosure of 20 A, TP MCB metalic for 415 Volts complete all as specified and directed
S&F in replacement MCCB 4 pole 160A, 36kA adjustable thermal & fixed magnetic setting complete all as specified and directed
S&F in replacement MCCB 4 pole 100A, 36kA adjustable thermal & fixed magnetic setting complete all as specified and directed
S&F in replacement MCCB 4 pole 63A, 25kA adjustable thermal & fixed magnetic setting complete all as specified and directed
S&F in replacement MCB 6-32 Amp SP complete all as specified and directed
S&F factory made sheet metal enclosers distributed board double door three phase 415 volts 8 way for MCCB 200 Amp, 4P as incoming and MCB (TPN) as outgoing comprising three phase four wire copper strip bus bar of appropriate capacity including dismantling of old DB complete all as specified and directed. Note : (i) The DB shall be VTPN specified makes listed in Appendix 'B'. (ii) The DB Shall be flush fixed and making good the distrubed surface matching with existing specification shall be part of job at no extra cost. (iii) Connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin / bottle type thimble-properly crimped. (iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.
S&F factory made sheet metal enclosers distributed board double door three phase 415 volts 4 way for MCCB 200 Amp, 4P as incoming and MCB (TPN) as outgoing comprising three phase four wire copper strip bus bar of appropriate capacity including dismantling of old DB complete all as specified and directed. Note : (i) The DB shall be VTPN specified makes listed in Appendix 'B'. (ii) The DB Shall be flush fixed and making good the distrubed surface matching with existing specification shall be part of job at no extra cost. (iii) Connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin / bottle type thimble-properly crimped. (iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.
S&F factory made sheet metal enclosers distributed board double door three phase 415 volts 8 way for MCCB 200 Amp, 4P as incoming and MCB (SPN) as outgoing comprising three phase four wire copper strip bus bar of appropriate capacity including dismantling of old DB complete all as specified and directed. Note : (i) The DB shall be VTPN specified makes listed in Appendix 'B'. (ii) The DB Shall be flush fixed and making good the distrubed surface matching with existing specification shall be part of job at no extra cost. (iii) Connection of the MCCBs/ MCBs with cable shall be made through appropriate size pin / bottle type thimble-properly crimped. (iv) All the vacant holes of the DB shall be provided with blank plates of appropriate size.
S&F in repair existing of U/S MCB TP 450 volt 10 KA C curve type of capacity 100 Amps complete all as specified and directed.
S&F in repair existing of U/S MCB TP 450 volt 10 KA C curve type of capacity 63 Amps complete all as specified and directed.
S&F in repair existing of U/S MCB TP 450 volt 10 KA C curve type of capacity 40 Amps complete all as specified and directed.
S&F in replacement complete power pack 110 volt 10 Ah, comprising 55 Nos batteries of capacity 2 volts each, UPS suitable for backup supply upto 10 Hrs with 110 Volts DC output complete all as specified and directed.
S&F in repalcement surge protection device of capacity 10 KA complete all as specified and directed.
M&L for servicing by the manufacturer / Auth Engineer, Repair / Maint and pressure test of compact efficient tank mounted Air compressor screw type, Model No. IA MAC-7.5, Make-INDO-AIR , 25.10 CFM capacity and refrigerated compressed air dryer model No. SED 010 Sanpar) including check & replacement all unserviceable, Burnout electric /Electronic parts, rewiring of control unit, change of indocool fluid oil, oil filter element, motor lubrication, solenoid valves, V-belts, flexible tubes & cleaning of strainers, oil scavenging line, cooler internals, motor, starter, electric control panel and dismantling the drain completely and clean all the components and replacement unserviceable contactor as per existing make & capacity, check the compressor complete all as specified and directed. NOTE:- Replacement of defective Minor parts shall be deemed to be included in the unit quoted rate.
M&L for preparation of old painted surface and applying one coat of paint of washing machine of capacity 30kg/40kg/60kg, UPS capacity 20 KVA/30 KVA, Hydro Extractor, Flat bed press etc complete all as specified and as directed.
Supply and fixing in replacement of tall tubular inverter battery of capacity 12 volts 180 Ah complete all as specified and directed.
Material and labour for mild steel in Rolled sections as in main and cross beams, hip and jack rafters;purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates (Fe-290 (Gde E-165) including dismantling complete all as specified and as directed.
Excavating in post holes (or similar holes) each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers n.exc 25 cm, watering and removing surplus soil to a distance n.exc 50 m and making good surface in soft/loose soil complete all as specified and directed.
Material & labour for PCC (1:4:8) type D-2 using 40mm graded crushed stone aggregate as in foundation, filling around fencing posts complete all as specified and directed
M&L for Earthing complete with galvanized steel earth plate electrodes 600 mmx600 mm x 6 mm thick buried directly in ground earth plate not less than 2.25 m deep below normal ground level with top edge of the plate not less than 1.5 m below normal ground level connected to and including galvanized GI strip 32X6mm by means of bolts, nuts, check nuts and washers of galvanized iron and steel including PCC pit in PCC (1:2:4) type B-1 using 20 mm graded crushed stone aggregate, RCC frame with 40mm thick RCC cover reinforced with 8mm dia deformed bars handle. including excavation and earth work in any type of soil medium grade GI watering pipe 20mm bore with funnel and wire mesh and light grade GI protection pipe 40 mm bore main board complete all as shown in electrical plate No 3 connected to main control board all as specified and testing on completion including dismantling of old earth plate complete all as specified and directed. Note: (i) Rate of excavation, earthwork, charcoal, PCC pit is covered under this item. (ii) The unit rate includes for protection pipe and GI strip 32 x 6mm from top of earth plate up to 7.5 meter above ground level.
S&F in repairs of earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 32x6mm galvanised iron strip complete all as specified and directed.
Supply and fixing in replacement LT heavy duty 4 pole on load changeover 415V 400 Amp complete with suitable outdoor panel IP 65 protection made out of CRCA mild steel sheet, thickness 2.25 mm single door with lock arrangement and grouting on ground including all necessary electrical connections with accessories complete all as specified and as directed.
Supply and fixing in replacement LT heavy duty 4 pole on load changeover 415V 630 Amp complete with suitable outdoor panel IP 65 protection made out of CRCA mild steel sheet, thickness 2.25 mm single door with lock arrangement and grouting on ground including all necessary electrical connections with accessories complete all as specified and as directed.
Supply and fixing of Fibre glass reinforced translucent corrugated sheeting having 2mm thickness with two corrugations side lap fixed with coach screw and washer in roof, wall etc including necessary fitting work complete all as specified and as directed.
Mahaveer Traders (BID ID -3473883)
M/S SOLANKI GENERAL SUPPLIERS (BID ID -3472587)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.57 MB
BOQ_823547.xls
BOQ • 0.40 MB
tender.pdf
Tender Documents • 1.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .