Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.5 LAccepted-AOC 161 MISSION INTER COLLEGE ROAD VILL PITHORAGARH DISTRICT PITHORAGARH STATE UTTARAKHAND PIN 262501 | PITHORAGARH | PITHORAGARH | UTTARAKHAND | 262501 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹42.8 L+₹1.2 L (2.91%)Rejected-Finance | L2 | Rejected-Finance OTHER THAN LOWEST | |
| 3 | L3₹44.6 L+₹3.0 L (7.16%)Rejected-Finance | L3 | Rejected-Finance OTHER THAN LOWEST | |
| 4 | L4₹45.2 L+₹3.6 L (8.57%)Rejected-Finance WARD NO 20 BIRLA HOUSE JEDERUA KALA DISTT GWALIOR M P 474006 | GWALIOR | GWALIOR | MADHYA PRADESH | 474006 | L4 | Rejected-Finance OTHER THAN LOWEST | |
| 5 | L5₹45.5 L+₹3.9 L (9.36%)Rejected-Finance 81 82 GHER SAIKH MITHOO KUBRHI PAKHAR ZAKHERA BAREILLY UP | BAREILLY | BAREILLY | UTTAR PRADESH | L5 | Rejected-Finance OTHER THAN LOWEST |
Tender Value
₹43.6 L
EMD Value
₹87,240
Closing Date
21 Aug 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
COL A S BHANDARI
HQ CWE HILLS PITHORAGARH POST BHARKATIA PIN 262520
CA NO CWE / HILLS / PGH/30 OF 2021-2022 PROVN OF INFRASTRUCTURE FOR OXYGEN GENERATION PLANT IN MH UNDER GE PITHORAGARH
2021_MES_464210_1
CA NO CWE / HILLS / PGH/30 OF 2021-2022
Open Tender
Miscellaneous Works
Item Rate
90 days
PITH0RAGARH
CLASS D
10 documents required · 10 mandatory
₹500
Yes
GE PITHORAGARH
₹87,240
Yes
24 Aug 2021
31 Jul 2021
23 Aug 2021
31 Jul 2021
21 Aug 2021
16 Aug 2021
1 Aug 2021 - 15 Aug 2021
60 days
Amount
Excavation in trenches not exceeding 1.5m wide and not exceeding 1.5M in depth for foundation etc and getting out in hard/dense soil complete all as specified and as directed.
Surface excavation n exc 30cm deep and averaging 15cm deep and getting out in harde/ dense soil complete all as specified and as directed.
Returning filling including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and as directed.
Filling under floor including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and as directed.
Filling under floor (except material) including spreading, levelling, watering and well ramming in layers n exc. 25cm complete all as specified and as directed.
Removing excavated material (soils) n .exc 50 m and depositing, where directed at a level n. exc 1.5 m above the starting point complete all as specified and as directed.
M&L for PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundation filling and mass concrete complete all as specified and as directed.
M&L for RCC 1:1.5:3 (Nominal Mix) using 20 mm graded stone aggregates as in foundation, including raft, footings, foundation beams, plinth beams, bases for columns etc complete all as specified and as directed.
M&L for RCC 1:1.5:3 (Nominal Mix) using 20 mm graded stone aggregates as in columns, pillars, piers etc complete all as specified and as directed.
M&L form work to sides of concrete foundations, footings, bases of columns, raft and raft beams, plinth beams, drain sides or similar works vertical or to batter for rough finished surface of concrete complete all as specified and as directed.
M&L form work to sides of pillars, posts, struts, columns for rough finished surface of concrete complete all as specified and as directed.
M&L mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality conforming complete all as specified and as directed.
M&L mild steel TMT bars 5 mm dia and over and including 10mm dia in stirrups, spacers and binders, cut to length, bent to shape required including cranking, bending spirally for hoping for columns hooking ends and bindind with ms wire (annealed) not less than 0.9mm dia quality confirming complete all as specified and as directed.
M&L precast cement concrete Block Masonary with solid blocks type C1 1:3:6 20mm graded stone aggregate exc 10cm in width and setting in mortar 1:6 complete all as specified and directed.
M&L 15 mm thick cement plaster on fair faces of brick work or concrete surface on wall in CM 1:4 mixed with water proofing compound as per manufacturer instruction, finished even and smooth without using extra cement complete all as specified and directed. (Note:- WPC shall be measured and paid separately)
M&L 15 mm thick cement plaster on fair faces of brick work or concrete surface on wall in CM 1:6 finished even and smooth without using extra cement complete all as specified and directed.
Supply only Liquid water proofing compound, complete all as specified and directed.
M&L for hard core of broken stone or boulders gauge n.exc 63mm deposited, spread and levelled in layers n.exc 15cm thick, watered and rammed to a true surface of broken bricks aggregate complete all as specified and directed.
M&L for 100 mm thick PCC 1:3:6 of type C-2 using 40mm graded stone agrregate as in sub base of floors etc complete all as specified and directed.
M&L for 50 mm thick PCC 1:2:4 of type B1 using 20mm graded stone aggregate as in floors finishing the surface even and smooth with using extra cement complete all as specified and as directed.
S&F chequered tiles rubber moulded, glossy finished, decorative designed cement concrete tiles 25 mm thick size of tiles as approved, set, jointed and pointed in neat cement slurry with grey cement and pigments in floor including 15 mm thick screed bed or bedding layer with cm 1:4 complete all as specified and as directed.
M&L for 75 mm thick PCC 1:3:6 type C-2, (using 40mm graded stone aggregate) as in plinth protection laid in alternate panels finished even and smooth without using extra cement complete all as specified and as directed.
M&L for forming construction joints 30mm deep x 10mm wide filled with sealing compound grade "A" complete all as specified and directed.
S&F Glass dividing strips, 3 mm thick and 38 mm wide inserted in position and conforming to design complete all as specified and directed.
M&L for PCC 1:3:6 type C-2 using 40mm graded stone aggregate as in surface channels and drain complete all as specified and directed.
Extra for forming fair finished drain or channel 30 cm inner girth in cement concrete using extra cement incl forms, moulds, mitred stopped ends etc. complete all as specified and directed.
M&L for providing cement concrete type B1 1:2:4 using 20 mm graded stone aggregate, as in coping, bed blocks including necessary form work complete all as specified and directed.
M&L for preparation of new or previously untreated plastered surfaces of walls and applying two coats of cement based paint on walls, over a coat of alkali resistant primer complete all as specified and directed.
M&l for preparation of new or previously untreated plastered surfaces of walls and applying three coats of white wash complete all as specified and directed.
M&L for preparation of new steel or iron surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and directed.
M&L for preparation of new steel surfaces of any description, n.exc 10cm in width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
S&F Mild steel Tie bars with screwed ends, nuts, washers and mild steel plates for walls, chimneys, roofs, arches, etc. king rods and straining bolts conforming to Fe 290 Gde-E-165 complete all as specified and directed.
S&F Mild steel screw bolts machine made any dia and any length with hexagonal or square heads at one end and screwed the other, or screwed both ends, each screwed end to be fitted with washers and one hexagonal or square nut complete all as specified and directed.
S&F MS framed work such as grills grating etc. with ends of bars sholdered and / or riveted into spikes, framed guard bars / railings and similar work conforming to Fe. 290 Gde-E-165 complete all as specified and directed.
S&F Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
S&F rolled mild steel framed work,Fe 410 -W (GdeE- 250) quality A, as in doors or gates of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete all as specified and directed.
S&F Mild Steel Rolled sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides for sliding doors; fixed with angle cleats or other connecting plates Fe 410 -W (Gde E- 250) quality A complete all as specified and as directed.
S&F Mild steel plain black sheets 0.63 mm thick as in hearths; covering to door shutters; covering to door chowkats (frames); waters tanks; water troughs; ducts; urinal troughs and funnels, etc. cut to size, edges beaded if directed, holes punched; including round headed screws, clout nails or rivets and fixed to wood or steel members, etc., with plain 40mm lap joints or welded/riveted seams including bending, turning up, mitred angles, stopped ends, outlets, etc. as required complete all as specified and as directed.
S&F Pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Pre-painted galvalume aluminum zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws complete all as specified and directed.
S&F Hard drawn Welded steel wire fabric of weight n exc 4 kg/sqm complete to wood or steel members complete all as specified and directed.
S&F steel tubular electric pole, swaged type, welded type, 410 SP-55 (11 meter long) complete with CI base plate, pole cap, bolts, nuts & screws all as specified including the following:- (i) Excavation in post hole not exceeding 1.5 Mtr wide & 2 Mtr deep for pole foundation & getting out in hard / dense soil, returning, filling in the excavated soil after fixing the pole in foundation, ramming earth around in layers n.exc 25 cm thick and disposal of surplus soil to a distance n.exc 50 meters. (ii) M&L for providing PCC 1:4:8, type D-2 ( using 40 mm graded stone aggregate) in base of pole of size 600mm x 600mm x 150 mm all as specified and directed. (iii) M&L for providing PCC 1:3:6, type C2 ( using 40 mm graded stone aggregate) in foundation 600mm x 600mm x 1800 mm (sub base as mass concrete) for concrete encasing the pole up to GL all as specified and directed. (iv) M&L for providing PCC 1:2:4, type B-1 (using 20 mm graded stone aggregate) for plinth block /Collar above GL, 300 mm high and 450 mm dia or as directed by EIC complete all as directed and as specified. (v) M&L for painting of pole externally with two coats of black bituminous paint up to planting depth. The remaining portion of exterior shall be painted with one coat of red oxide primer and above plinth block/ concrete collar with two coats of aluminium paint including preparation of surfaces including painting of 30 cm wide black and yellow bands (strips) 5 Nos with synthetic enamel paint in alternate layers upto the height of 1.5 Mtr above plinth block and writting pole number and feeder location by white synthetic enamel paint with proper letter size as directed.
S&F cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination heat shrink type end joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 sqmm, 3 core, complete all as specified and directed
Supply installing testing & commissioning of AC 3 phase 50 cycle per second 160 KVA capacity transformer confirming to IS 1180, copper wound, step down, outdoor type, 11000/433 volts copper wound oil immersed naturally, cooled with internal cooling tubes delta connected on primary ( HV) side and star connected on secondary ( LV) side in accordance with vector symbol Dy-11 ( Vector group IV) with neutral brought on secondary ( LV ) ride and having at (+/-) 2.5%, (+/-) 5% and 7.5% taping to be changed by means of hand operated “ OF LOAD” tape changing gear. The maximum temp raised should not be exceeded 45 degree centigrade in oil and 55 degree centigrade in HV & LV winding when measured by resistance method after continuous full load run and in ambiant temperature of 40 Degree Centigrade . Transformer shall be complete with standard fitting and comprising the following:- (a) One cable box on LV side ( secondary side) consist of 4 Nos. porcelain bushing with studs made out of copper with nuts and washers and one cable glands suitable for reception of taking out one No 3.5 core LT cable of requested size 1100 volts grade PVC sheathed and PVC insulated armoured heavy duty. b) Conservator with drain valve and oil level indicator. (c) Dehydrating breather with first fill of dehydrating agent silica gel. (d) Explosive vent. (e) Thermo meter pocket on tank cover. (f) 01 No. 100 mm dia dial type thermo meter vapour pressure type having range –120 degree C with more reading pointer maximum indicator and re-setting device. (g) Rating plate with terminal marking. (h) Two earthing terminal on tank and tank cover to facilitate fixing of 30x6 mm GI strips. (j) Oil level gauge. (k) Oil drain and filter valve. (l) Lifting lugs / hooks. (m) Oil filter hole with cap / plug with connection complete. (n) Air relief valve plugs. (o) Four plain solid cast steel detachable by directional rollers. (p) Extra bushing for neutral outside the cable for providing independent earthing for neutral. (q) First filling fresh oil conforming to relevant IS and tested up to 40 KV dielectric strength.
Supply, installing, testing & commissioning of Voltage Stabilizer for automatic operation, three phase naturally oil cooled outdoor type & designed for input variation between 340 V to 460 V with output voltage stabilized at 415 with accuracy (+/-) 2.5% and speed of correction 8 volts per second and capacity of 160 KVA including filling of transformer oil of suitable capacity complete all as specified and directed.
Supply, installation, testing and commissioning of zonal valve box for two gases with locking arrangement and glass cover fitted complete with valves and brass connectors, complete all as directed.
Supply, laying & testing of cable XLPE insulated, screened , PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty)1100 volts grade with stranded aluminium conductor of cross sectional area 150 Sqmm, 3 .5 core, complete all as specified and directed.
Supply, laying & testing of cable XLPE insulated, screened , PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty)1100 volts grade with stranded aluminium conductor of cross sectional area 70 Sqmm, 3 .5 core, complete all as specified and directed.
Supply, laying & testing of cable XLPE insulated, screened , PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty)1100 volts grade with stranded aluminium conductor of cross sectional area 50 Sqmm, 3 .5 core, complete all as specified and directed.
Supply, laying & testing of cable XLPE insulated, screened , PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty)1100 volts grade with stranded copper conductor of cross sectional area 25 Sqmm, 4 core, complete all as specified and directed.
Supply, laying & testing of cable XLPE insulated, screened , PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty)1100 volts grade with stranded copper conductor of cross sectional area 16 Sqmm, 4 core, complete all as specified and directed.
Supply, laying & testing of cable XLPE insulated, screened , PVC bedded, galvanized steel strip or wire armoured electric power cables (heavy duty)1100 volts grade with stranded copper conductor of cross sectional area 4 Sqmm, 2 core, complete all as specified and directed.
S&F 80mm bore, GI pipe, light grade, fixed to poles, walls with & including flat iron clamps bolts / nuts / washers / fittings (if any), complete all as specified and directed.
S&F HT lightening arrester metal oxide type (gap less) for outdoor use complete with all fittings and fixing arrangements, transmission class discharge capacity 65 kilo amps suitable for 11000 volts including brackets, clamps, nuts, bolts, washers and connecting to GI earth wire 4mm dia including with manufacturer’s test certificate, complete all as specified and directed.
S&F of air break gang operated triple pole, mechanically operated, mounted on HT insulators and galvanised steel frame with operating rod of 25 mm dia medium grade GI pipe suitable for operation while standing on ground for current rating 200 Amps suitable for 11000 volt , 50 HZ, including supply of 12 Nos. insulator of appropriate size and drop out fuse carrier element, complete all as specified and directed
Supplying and laying factory made un-reinforced precast concrete cable cover, class HVP, type 1 with peak, size 300mm x 180mm x 40mm, laid dry flat across the cable with length of whole PCC cover, complete all as specified and directed.
M&L for construction of brick masonry platform of size 3.00m x 3.00m, suitable for mounting of 160 KVA capacity transformer with and including of following provisions, complete all as specified in PS clause 38 hereinafter and directed.
S&F danger notice plate of 1.6 mm thick mild steel sheet, vitreous enamelled white, with letters, figures and conventional skull and bones in signal red colour and fixed with MS clamps made out of flat iron 25x3mm, bolts and nuts of approved size for HT 25 x 20 cm size complete all as specified and directed.
Supplying, installing, testing and commissioning of medical grade copper pipe line solid, drawn seamless, deoxidised, manufactured as per BS-2871, Part-I, Table-X of 1971 and chemical composition as per BS-6017 of 19811e-2 CU DHP of the following sizes, complete all as directed:- (a). 22mmx0.90mm
(b). 15mmx0.90mm
(c). 12mmx0.90mm
Supplying, fabricating, fixing in position cross arms, bracings, supports, clamps and back plates, fabricated from in structural steel section any type /size /shape including nuts bolts washers, welding, bending hot or cold, drilling holes for bolts, in any shape or size as required at site, including painting with two coats aluminium paint over a coat of red oxide including dismantling of old unserviceable existing cross arms complete all as specified and directed.
Excavation in trenches not exceeding 1.5M wide and not exceeding 1.5M in depth for laying under ground cable, not exceeding 10 sqm on plan and getting out in any type of soil complete all as specified and as directed.
M&L for sand cushioning with layer of sand 8cm thick before laying of cable and 15cm after laying of cable in trenches as in sand cushioning to underground cable, complete all as specified and directed
Supply & laying of sub class ‘B’ old size bricks, laid flat i.e length of brick shall be laid across the length of cable for protection of under ground cable complete all as specified and directed.
Supplying and laying PVC underground cable, XLPE insulated, screened with extruded semi conducting compound in combination with copper tape (0.3 KA for 1 sec) cores laid up, inner PVC sheathed, galvanised steel strip armoured, overall PVC sheathed electric power cables (heavy duty) with stranded compact aluminium conductor, 11000 volts grade, cross sectional area 95 Sqmm, 3 core, confirming to IS:7098 (Part-II) with latest amendments, suitable for earthed system laid in duct / trenches/ along pole etc. including making connection, complete all as specified directed.
Supply, installation, testing and commissioning of shutoff valve with compatible brass connectors of following sizes, complete all as directed:- (a). 22mm dia.
(b). 15mm dia.
(c). 12mm dia.
M&L for earthing complete with GI earth plate electrode 600x600x6 mm thick burried in ground vertically to a depth ot less than 2.25 mtr below the ground level eith top edge of the earth plate surrounded 15cm thick layers of common salt charcoal dust starting from ground below 15 cm of earth plate upto 15 cm above the same. GI plate connected with galvanised steel of size 32x6 mm by means of GI nuts,bolts and washers, strips as shown in electrical plate No.3 of MES SSR Part-I(2009), burried in 40 mm dia light grade GI pipe as protection from top of the up to test point (cost of protection pipr up to 7.5 mtr from earth electrode will be included in the rates quoted by the contractor) including with the following provisions:-(a) Test point GI strip of size 32 mm x 6mm. (b) watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit (GI funnel should properly tightned on GI waterning pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits).(c) Earth pit 30x30 cm constructed in PCC 1:2:4 type B1 exposed surfaces finished even and smooth with 15 mm thick cement mortor 1:6 including pit cover of RCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable MS hadle-01 No. of 10 mm dia bar suitable for carying of pit cover complete all as specified and directed. Note :- (i) Item includes the cost of 7.5 m GI pipe for protection of GI strip. (ii) Item includes cost of 7.5 m earth lead i.e GI strip 32x6mm. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
Supply, installation, testing & commissioning of oxygen outlet points CE marked, front loaded complying IS12827of 1989 with non-interchangeable probe connectors, complete all as directed.
M&L for earthing complete with copper earth plate electrode 600 x 600 x 3.15 mm thick burried in ground vertically to a depth ot less than 2.25 mtr below the ground level eith top edge of the earth plate surrounded 15cm thick layers of common salt charcoal dust starting from ground below 15 cm of earth plate upto 15 cm above the same. Copper plate connected with copper strip of size 20x3 mm by means of copper nuts,bolts and washers, strips as shown in electrical plate No.3 of MES SSR Part-I(2009), burried in 40 mm dia light grade GI pipe as protection from top of the up to test point (cost of protection pipr up to 7.5 mtr from earth electrode will be included in the rates quoted by the contractor) with and including the following porvisions:-(a) Test point copper strip of size 20x3mm. (b) Watering pipe GI light grade 20mm dia from top of the earth electrode up to MS funnel with wire mesh embeded in floor of PCC earth pit (GI funnel should properly tightned on GI waterning pipe and embeded in PCC floor of earth pit with open top suitable for watering of earth pits).(c) Earth pit (30x30 cm) constructed in PCC 1:2:4 type B1 exposed surfaces finished even and smooth with 15 mm thick cement mortor 1:6 pit cover of RCC 1:2:4 type B-0 using 12.5 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides with suitable MS hadle-01 No. of 10 mm dia bar suitable for carying of pit cover complete all as specified and directed. Note :- (i) Item includes the cost of 7.5 m 40mm dia GI pipe for protection of copper strip. (ii) Item includes cost of 7.5 m earth lead i.e copper strip 20x3mm. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the quoted rates.
Supply, installation, testing, commissioning of digital alarm system with audiovisual alarm for two gases, complete all as directed
Supply, installation, testing and commissioning of back flow compensated flow meter with humidifier bottle flow range 0-15 litre / minute, complete all as directed
M&L for earthing complete with galvanised steel earth plate electrode including necessary excavation and earth work in any type of soil with galvanized steel earth plate electrode size 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs below ground level) with top edge of the earth plate not less than 1.5 mtr below normal ground level connected to with and including galvanised earth wire 4 mm dia up to 7.50m by means of bolts nuts check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of MES SSR Part-I(2009) connected to main switch board or main control board all as specified and testing on completion with & including provision of earth wire protected by galvanized iron 15mm dia. light grade pipe up 7.50m and watering pipe shall be 20 mm bore medium grade with and including conctrete pit shall be PCC 1:3:6 tye C -1, 40 mm thick pre cast cover slab in RCC (1:2:4) type B-1 using 20 mm graded stone aggregate duly reinforced with 8 mm TMT bars @100mm C/C on both sides and cover flushed with the pit with suitable cast iron fitting handle. GI earthing wire shall be encased in and including light grade tubing with all fittings from earth plate upto the connecting point complete all as specifed and as directed. Note :- (i) Item includes the cost of 7.5m 15mm dia GI pipe, light grade for protection of earth wire. (ii) Item includes cost of 7.5 M earth lead wire. (iii) PCC pit shall be provided at least 500 mm away from the pit and not on the earth pit itself and the extra cost of additional length of watering pipe, bends, elbow etc shall be deemed included in the unit rate.
KPELECTRICAL AND AUTOMATION
M/S YOGANSH CONSTRUCTION CO.
J.N.R. Engineers and Builders
shahji contractors
anand enterprises
kumaon and hills strument engnering services
M/S HINA ELECTRICALS
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .