Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.1 LAccepted-Finance 1 1 NORTH ROAD JADAVPUR KOLKATA | KOLKATA | WEST BENGAL | ₹3.1 L | L1 | Accepted-Finance Accepted |
| 2 | L2₹3.2 LRejected-Finance 7G CORNFIELD ROAD KOLKATA 700019 | PASCHIM BARDHAMAN | WEST BENGAL | 713305 | ₹3.2 L | L2 | Rejected-Finance higher than L1 |
| 3 | L3₹3.2 LRejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | ₹3.2 L | L3 | Rejected-Finance higher than L1 |
| Sl No | Description | Qty | Unit | CONCORD ENGINEERING L2 | MACHINE SUPPLIERS SYNDICATE PVT LTD L1 | WEST BENGAL ENGINEERING CO. L3 |
|---|---|---|---|---|---|---|
| 1.00 | Dismantling the defective line shaft from motor and pump end of 30kW sewage pump No. – 2 & 3, after decupling line shaft and placing the same at pump floor, all complete as per direction of the EIC. | 2 | NOS. | 7,320 ₹14,640 | 7,200 ₹14,400 | 7,400 ₹14,800 |
| 2.00 | Transportation charge for carrying of defective line shaft from worksite to workshop, to and fro including loading unloading complete. | 1 | ITEM | 6,150 ₹6,150 | 6,100 ₹6,100 | 6,200 ₹6,200 |
| 3.00 | Balancing of SS line shaft of 30kW sewage pump No. – 2 & 3 (1 Big size) | 2 | NOS. | 8,700 ₹17,400 | 8,600 ₹17,200 | 8,750 ₹17,500 |
| 4.00 | Balancing of SS line shaft of 30kW sewage pump No. – 2 & 3 (1 Small size) | 2 | NOS. | 7,700 ₹15,400 | 7,650 ₹15,300 | 7,750 ₹15,500 |
| 5.00 | Supply & delivery at site Bearing No-22212K [Make : SKF] for 15kW sewage pump (position - 2) Intermediate bearing. | 1 | NO. | 12,700 ₹12,700 | 12,600 ₹12,600 | 12,760 ₹12,760 |
| 6.00 | Labour charges for refitting the Balancing line shaft with supplying necessary materials and making proper alignment between pump, intermediate shaft and motor with testing & Commissioning all complete as per direction. | 2 | NOS. | 4,650 ₹9,300 | 4,600 ₹9,200 | 4,700 ₹9,400 |
| 7.00 | Supplying and delivery at site Disapad 120 mm OD Hexagon (BI-23.5) [Any approved make] | 10 | NOS. | 7,720 ₹77,200 | 7,645 ₹76,450 | 7,800 ₹78,000 |
| 8.00 | Labour charges for Dispad replacement of line shaft from motor and pump end of (30kW - 3 nos. and 15kW - 2 nos) after decupling line shaft and placing the same at pump floor and refitting the same with supplying necessary materials and making proper alignment between pump, intermediate shaft and motor all complete as per direction. | 1 | ITEM | 15,300 ₹15,300 | 15,250 ₹15,250 | 15,400 ₹15,400 |
| 9.00 | Wiring arrangement of dry-run protection of pump set by tripping of pump-motor set at low level of sump by modification of internal wiring of ATS stater panel by skilled personal including supply of necessary materials (i.e. Aux. contact, socket, cable alley etc.) with testing and commission all complete as per direction. | 9 | SETS | 2,600 ₹23,400 | 2,550 ₹22,950 | 2,700 ₹24,300 |
| 10.00 | Supply, delivery at site 48" ceiling fan [Make : Havells / CG / Approved make] | 2 | NOS. | 2,620 ₹5,240 | 2,590 ₹5,180 | 2,800 ₹5,600 |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
8 Apr 2026, 12:00 pmClosed
Executive_Engineer_NTKMD_PHED
Utility_Bldg__Beside_Delhi_Public_School_AA_ID_New_Town_Kol_700156
Balancing of line shaft with rectification of alignment of 30kW Sewerage pump-motor (Position - 02 and 03) including allied works at PS-IV, AA-II in New Town under NTK Project.
2026_PHED_1021147_1
PHE/NTKMD/e-21 of 2025-26
Open Tender
Project Work
30 days
WORK
Please refer Tender documents.
5 documents required · 5 mandatory
₹7,000
11 May 2026
13 Mar 2026
10 Apr 2026
14 Mar 2026
8 Apr 2026
14 Mar 2026
Dismantling the defective line shaft from motor and pump end of 30kW sewage pump No. – 2 & 3, after decupling line shaft and placing the same at pump floor, all complete as per direction of the EIC.
Transportation charge for carrying of defective line shaft from worksite to workshop, to and fro including loading unloading complete.
Balancing of SS line shaft of 30kW sewage pump No. – 2 & 3 (1 Big size)
Balancing of SS line shaft of 30kW sewage pump No. – 2 & 3 (1 Small size)
Supply & delivery at site Bearing No-22212K [Make : SKF] for 15kW sewage pump (position - 2) Intermediate bearing.
Labour charges for refitting the Balancing line shaft with supplying necessary materials and making proper alignment between pump, intermediate shaft and motor with testing & Commissioning all complete as per direction.
Supplying and delivery at site Disapad 120 mm OD Hexagon (BI-23.5) [Any approved make]
Labour charges for Dispad replacement of line shaft from motor and pump end of (30kW - 3 nos. and 15kW - 2 nos) after decupling line shaft and placing the same at pump floor and refitting the same with supplying necessary materials and making proper alignment between pump, intermediate shaft and motor all complete as per direction.
Wiring arrangement of dry-run protection of pump set by tripping of pump-motor set at low level of sump by modification of internal wiring of ATS stater panel by skilled personal including supply of necessary materials (i.e. Aux. contact, socket, cable alley etc.) with testing and commission all complete as per direction.
Supply, delivery at site 48" ceiling fan [Make : Havells / CG / Approved make]
Supply, delivery at site of 400 mm sweep energy efficient Pedestal fan. [Make : Havells / CG / Approved make]
Supply, delivery at site of energy efficient LED highbay fixture with IP-66 and IK08 protected high pressure Al. Die Cast housing with polycarbonate cover. [Model : BY203P LED 83S CW PSU PC] [Make : Philips / Any other approved make]
Supply, delivery at site of street light luminarie IP-66 LM6-HPDC Housing Street light aerodynamically designed with better thermal management/ Potted driver is to be provided,the luminaire and housing should be from the same manufacturer. [Model : BRP 032P LED 75 CW SLR PSU GR SDP] [Make : Philips or equivalent and same techinal specification. Each fixure is to be earthed with the erected steel tabular pole]
Fitting fixing the above supplied materials on existing position by above supplied necessary materials [Sl. no. 10.00 to 13.00] with supply necessary materials as per direction of EIC.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.94 MB
Tendernotice_2.pdf
PDF • 0.90 MB
Tendernotice_3.pdf
PDF • 0.55 MB
Tendernotice_4.pdf
PDF • 0.22 MB
BOQ_2509888.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid