Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
Tender Value
₹165.7 Cr
EMD Value
₹1.6 Cr
Closing Date
7 Dec 2026, 3:00 pm
Eligibility, documents, scope, Go/No-Go checksEligibility, required documents, scope of work and Go/No-Go checks for this tender, in one click.
GM - Contract
Development and Construction of Depot Including OCC and Associated E&M Works near Shela of Ahmedabad Metro Rail Project
365441
GMRC/CONS/DEPOT-2/2026
Open
Civil Works
Works
Gandhinagar
9 documents required · 8 mandatory · 1 optional
₹25,000
₹1.6 Cr
12 Nov 2026
12 Nov 2026
12 Nov 2026
7 Dec 2026
12 Nov 2026
180 days
Bill of Quantity (BOQ)
Gujarat Metro Rail Corporation (GMRC) Limited
(SPV of Govt. of Gujarat and Govt. of India)
Formerly known as Metro Link Express for Gandhinagar and Ahmedabad (MEGA) Co. Ltd.
Block No.1, First Floor, Karmayogi Bhavan, Behind Nirman Bhavan,
Sector 10/A, Gandhinagar:
Corporate Identification No (CIN): U60200GJ2010SGC059407
GMRC/CONS/DEPOT-2/2026 BOQ
PREAMBLE AND GENERAL REQUIREMENTS FOR ELEVATED SECTION
The Pricing Document shall be read in conjunction with technical Specification, Employers Requirement,
BOQ’s for the works and other provisions of the tender documents, Schematic tender drawings etc.
including Annexure, Appendix, Addendum / corrigendum and any other document forming part of the
Tender Document.
The Bill of Quantities shall be read in conjunction with the Instructions to the Tenderer, General Conditions of
1. Contract, Special Condition of Contract, Employers Requirement, Scope of work, technical specifications and
drawings etc. If the specifications in the scope of work, Employers Requirement, Technical specification are
inferior with respect to relevant codes and standards then the provision of the Codes and Standards shall
prevail and vice versa. The decision of the Engineer-in- charge regarding this issue shall be binding on the
The quantities given in the Bill of Quantities are estimated and provisional and are given to provide a common
2. basis for bidding. The basis of payment will be the actual quantities of work carried out, as measured by the
Contractor and verified by the Engineer and valued at the rates and prices tendered and accepted in the priced
Bill of Quantities, where applicable, and otherwise at such rates and prices as the Engineer may fix within the
terms of the Contract. The final executed work quantities may vary.
The rates for each item and the Schedule of Items shall be written in indelible ink or type written in the
3. summary sheet in words and figures. Therefore, the quoted price for each Schedule shall be calculated and
written against each Schedule of the work. The total price, as sum of quoted price for all the Schedules of the
work shall be shown at the bottom of the summary sheet. The total price shall also be written in words and
figures. In case of any discrepancy, the amount written in words will be taken. The percentage/item rates shall
be quoted and amount evaluated in Indian Rupees only. as applicable against Schedule/items in BOQ, both in
figures and in words. The person authorized to sign on behalf of the tenderer shall sign in full at bottom of all
pages and at the end of schedule.
All the item of works which are not covered in BOQ Schedule A, B1, B2, C1, C2 and D of structure Section, but
4. are required to be carried out as per the direction of Engineer-in-Charge, shall be carried out under the
Schedule-H i.e. Provisional Sum Schedule as per below preference.
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be as per rates mentioned in above SOR excluding GST)
The rates in BOQ are exclusive of GST (18%) and custom duties but including all other Taxes and cess, octroi
5. etc. as on date of submission.
If the Tenderer fails to fill up the percentage rate, “In each Schedule of the Summary sheets” the offer will be
6. evaluated based on the Par rate (cash value rate of the tender) given in the BOQs and no claim on account of
this will be entertained from the tenderer. However, GMRCL reserve the right to disqualify the tenderer.
General directions and descriptions of work and materials are not necessarily repeated or detailed in the Bill
7. of Quantities. References to the relevant specifications and sections of the contract documentation should be
made before quoting rates in the Bill of Quantities.
The rates are deemed to be inclusive of all lead (except as otherwise specifically provided in the description of
8. the particular item), lifts, ascend, descend, handling, rehandling, crossing of Nallah/Streams/Tracks any other
All enabling works for executing the work e.g. approach road to site, launching arrangements, arrangement of
9. water and electricity and any other incidental works which can be reasonably be inferred to be required for
completing the works is to be arranged by the contractor at his own cost and deemed to be included in the
In all concreting items, all material, equipment, labour, casting beds, stress frames, form work staging,
10. scaffolding, etc is to be arranged by the contractor within the quoted rates.
Storage of Material: All the material at site will have to be properly stacked & stored so as to facilitate
11. inspection. The material should be properly protected from the detrimental effects of nature and fire, theft etc.
The contractor shall be responsible for watch & ward and any loss or deterioration on account of above shall
lead to rejection of material and the contractor has to replace the same at his own cost.
The method of measurement of completed work for payment shall be in accordance with provisions in
12. Contract/Specifications except as otherwise specifically provided in the description of item or particular bill
of quantities or explanatory notes to the particular bill of quantities.
GMRC/CONS/DEPOT-2/2026 BOQ
Obtaining prior permission for felling/cutting of trees will be in the scope of Contractor.
All materials to be supplied by the contractor within the quoted rate for the respective item.
All design mix concrete shall be machine batched with automatic weigh batcher, machine mixed and machine
15. vibrated or Ready Mix Concrete prepared in batching plant and transported by transit mixer to the site of work
or as directed by the structural designer.
The installation price of switchboards, metering panels, DB's or any other items shall include supply and fixing
16. of supporting steel structures/MS channels grouting of the same, associated civil works etc., as required. No
change in unit rate shall be allowed for any change in quantity or for any other reason whatsoever.
Prior to demolishing of any structure measurements will have to be taken. Scheme of dismantling has to be got
17. approved from the Engineer-in-charge.
All activities not specifically covered in BOQ /Schedule of Items, but required to be executed in order to
18. complete the Scope of work have to be deemed as covered with in these mentioned items of the Schedule /
Errors will be corrected by the Employer for any arithmetical errors in computation or summation as indicated
19. in the Contract Document.
The contractor must see the site conditions such as type of soil, locations etc., and take all factors into
20. consideration while quoting in the BOQ as no extra cost will be allowed on any ground arising out of or relating
to the site conditions. earth resistivity testing, water testing all shall be carried and cost of same shall be
considered included in the bid.
The contractor shall take into account the expenses of pre-commissioning tests to be conducted as per
21. specification of the complete installation by licensed agencies.
All temporary works shall be carried out by the contractor including temporary lighting & power at station
22. areas, Switchboards, DG sets, cables, stores, etc.
Repairs to damage of existing carriage way, canal work etc. during construction work shall be carried out by
23. contractor at his own cost as per the technical specifications. Prior to start of repairing work, scheme of repair
work shall be got approved from Engineer in charge.
For all type of cement concrete work rate shall inclusive of
24. I. The rate shall include cost of all necessary admixtures required as per mix design, curing, casting including
centering, shuttering, propping, staging, scaffolding, necessary tools, plants, machinery and all related
operations, etc.
II. The rate shall include cost of carrying out concrete mix design from approved laboratory as described in
the specification or as approved by Engineer-in-charge.
III. The rate is inclusive of all materials, including, mixing in fully automatic batch mix plant, transportation by
transit mixer for any lead from plant site, pumping, pouring, curing, placing in position, making good the
damages, with all lift with contractor's labour, tools & plants, machineries, as required.
IV. The rate is inclusive of providing formwork for exposed form finished concrete surface for concrete above
ground level in desired pattern, sizes with grooves, using laminated shuttering plywood/steel shuttering,
including neat cleaning & rendering of exposed concrete surface, as per the sample approved by the Architect
and as directed by the Engineer-in-charge. (Same kind of shuttering material should be only used for standard
and residual sizes)
V. The rate is inclusive of roughening and/or hacking exposed concrete surfaces for key for plastering, grinding
with carborundum stone over concrete spills / level difference in joints of concrete.
VI. The rate is inclusive of cost of providing grooves, chamfers, moulding, cutout etc. in formwork & using
required dosage of plasticizer in concrete for obtaining required workability as per approval of Engineer-in-
charge. The work will include vibration of concrete, curing protecting from damage, bailing/pumping out
water if required, levelling of ground, making site good etc.
VII. The rate is included labour for keeping embedment if any wherever required while casting.
VIII. The rate shall include form liner finish as per drawing / technical specifications.
The Tenderer’s offer shall be exclusive of GST. Income Tax and any other statutory taxes to be deducted at
25. source, if any, will be deducted by the Employer in accordance with the Income Tax Act and any other acts in
force and in accordance with instructions issued by the Authorities on this behalf, from time to time.
The Tenderer is required to furnish the PAN for all members of Group.
The rates and prices to be tendered in the Bill of Quantities are for completed and finished items of work and
27. complete in all respects. It will be deemed to have included all constructional plant, tools, machinery, labour,
supervision, materials, fuel, oil, consumables, elect& power, water, transportation, all leads and lifts,
GMRC/CONS/DEPOT-2/2026 BOQ
dewatering, all temporary works and false works, construction of temporary stores and buildings, fencing,
watering, lighting, erection maintenance, night working, inspection facilities, safety measures at work sites
casting yard for workmen and road users, preparation of design and drawings pertaining to the casting yard,
staging, shuttering, form work, stacking yard etc., establishment and overhead charges, labour camps,
insurance costs for labour and works, contractor's profit, all taxes, royalties, duties, cess, octroi, and other
levies and other charges together with all general risks, liabilities and obligations set out or implied in the
contract and including remedy of any defects during the Defect Liability Period, unless otherwise provided in
Annexure-13A as duly filled in and priced should be invariably submitted in the Financial Package as
28. mentioned under Para C15.1 of the I.T.T (Instruction to Tenderers) under Volume-1 of Tender-Document and
the evaluation of Financial Package by the Employer will be done in accordance with Para E5 of ITT and other
relevant terms and conditions of the Tender.
Tender Total to be sum of total amount as derived/ quoted in the summary sheet along with addition of Price
Tender Total to be sum of total amount as derived/ quoted in the summary sheet along with addition of Price
29. of unqualified withdrawal of all conditions of Deviation, as per Annexure-13A, if any. This Tender Total will be
used for comparative evaluation of the Tenders.
The tenderer shall include in the Annexure – 2, Tax Estimate of the tender document, the rates/amounts
30. considered in the state and central Tax, duties, levies and included in the tender price and Gujarat state
government taxes, cesses and levies.
The tenderer should quote his percentage against each Schedule in the “summary sheets of each part” only on
31. N Procurement Portal and nowhere else.
The preparation and submission of the design, drawings, etc. for the complete façade works, unitized structural
32. DGU glazing system and all of its elements, roofing with structural steel, space frame, polycarbonate sheet for
the courtyard and atrium, canopies shades at various locations, etc. is in the contractor's scope. The contractor
shall submit 3 qualified façade vendors/structural designers with substantial experience in similar projects.
GMRC will review and select the vendor. The contractor must then obtain designs from the selected vendor
and submit all designs, drawings, and calculations for approval.
All design criteria must comply with relevant codes, force factors, and load factors while maintaining the
original architectural intent. Following design approval, the contractor shall create mockups for final approval
by the Architect/GMRC before proceeding with execution. All these requirements are included in the
contractor's scope, and no additional payment will be made for these items.
The successful contractor shall submit the material sampled which are in co-ordination with interior work like,
33. detector, camera, switchboard, Distribution board, lighting, speakers etc.., to the Engineer for approval prior
to supply/commencement of such works. The approval of these samples to be sought from architect/GMRCL.
Any choice of color model asthetical options from approved makes shall be supplied by contactor at no extra
cost / commercials.
All material to be supplied at site shall be pre intimated to the engineer along with supporting FAT, material
34. test, type test reports and qty sheet along with specification compliance, unless the same is approved and
accepted the material shall not be supplied at site.
All expenses related to material FAT at factory or OEM location shall be borne by contractor, also the cost shall
35. include transportation, lodging & boarding of engineer / GMRCL team attending the testing at factory / OEM
location weather local / abroad.
The successful contractor shall submit 100% compliance against each and every BOQ line items & material
36. specification before work commencement at site or any material delivery at site.
The successful contractor shall submit the Schematic diagrams, fabrication drawings with details of all
37. equipment like D.G, Pumps, wirings diagrams etc., to the Engineer for approval prior to
supply/commencement of such works. The approval of these drawings will be general and will not absolve the
contractor of the responsibility of the correctness of these drawings. At least six copies of the approved
drawings shall be submitted to the Engineer for their distribution to various agencies at site at no cost to the
All testing and calibrating charges for the Meters shall be included in the installation price of the Meter Cubicle.
High voltage testing by Voltage Boosters, relay calibration by secondary injection and meter calibration have
39. to be carried out at site by authorized agencies.
GMRC/CONS/DEPOT-2/2026 BOQ
The contractor shall carry out DG set testing and commissioning including supply of fuel & other
40. consumables/accessories at site without any extra cost for supply of fuel & other consumables/accessories as
required or instructed by the Engineer. Supply of fuel for testing shall be provided by the Contractor after
successful testing DG tank shall be filled by contractor. All the charges for fuel is also included. No separate
payment shall be made for the supply of fuel.
The contractor shall supply all equipment, spares and consumables required for 104 weeks of Defect Liability
All wall and floor openings where cable containments are passing through shall be sealed with 2-hour fire
42. rated sealant after completion of cable pulling or installation.
The rate also includes all charges like packing and forwarding charges, handling, loading, unloading,
43. transportation, transit and other insurance, hoisting to all levels, setting and fixing in position, disposal of
debris including all other labour, Liabilities, obligations and risks arising out of conditions of contract and
Liaisoning for obtaining approval from CEIG, Fire clearances, Electrical Inspectorate & Local authorities.
All enabling works for executing the work e.g. approach road to site, launching arrangements, arrangement of
44. water and electricity and any other incidental works which can be reasonably be inferred to be required for
completing the works is to be arranged by the contractor at his own cost and deemed to be included in the
All items of E&M works which are not covered in BOQ but are required to be carried out as per direction of
45. engineer in charge will be based on list of concerned item as available in DSR (E&M)
Payment for scheduled E&M works shall be made as follows:
1) 65% on supply and delivery
2) 10% on installation
3) 15% on testing and commissioning
4) 5% on integrated testing and commissioning
5) 5% on taking over
Payment for the Comprehensive Annual Maintenance Contract (CAMC) shall be made in equal quarterly
47. installments over the 2-year contract period (totaling 08 installments), payable at the end of each quarter upon
submission of the service report and invoice.
GMRC/CONS/DEPOT-2/2026 BOQ
Name of Work: Development and Construction of Depot Including Associated E&M Works near Shela of Ahmedabad Metro Rail
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
(including percent above
Schedule No. & Description Basic Cost (INR) % at Par/above/below
/ below / at par of
Amount At Par Value)
Section Description of Section In Figure In Words In Figure In Words
1 Schedule-A GENERAL
2 Schedule -B1 CIVIL / STRUCTURAL WORKS (NDSR ITEMS)
3 Schedule -B2 CIVIL / STRUCTURAL WORKS (DSR ITEMS)
ARCHITECTURAL FINISHING WORKS (DSR
4 Schedule –C1 ITEMS)
ARCHITECTURAL FINISHING WORKS (NDSR
5 Schedule –C2 ITEMS)
6 Schedule -D PHE WORKS
7 Schedule –E1 Electrical System
Air Conditioning, Ventilation and Air
8 Schedule –E2 Distribution System
GMRC/CONS/DEPOT-2/2026 BOQ
Name of Work: Development and Construction of Depot Including Associated E&M Works near Shela of Ahmedabad Metro Rail
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
(including percent above
Schedule No. & Description Basic Cost (INR) % at Par/above/below
S No / below / at par of
Amount At Par Value)
Section Description of Section In Figure In Words In Figure In Words
9 Schedule –E3 Fire Detection & Alarm System
10 Schedule –E4 Fire Fighting System
Comprehensive Annual Maintenance for
11 Schedule –E5 years for Complete Electrical and Mechanical
Schedule F1 : Provisional Sum for Electrical
System, Air Conditioning,
Ventilation and Air Distribution System, Fire
Detection & Alarm System, Fire Fighting
12 Schedule -F System, Compressed Air System and Lifts
(installed at Workshop cum Admin Building
and Staff Quarters) including E&M Works of
Staff Quarters and Miscellaneous Works.
13 Schedule -G Miscellaneous Works
GMRC/CONS/DEPOT-2/2026 BOQ
Name of Work: Development and Construction of Depot Including Associated E&M Works near Shela of Ahmedabad Metro Rail
Annexure – 1, SUMMARY SHEET OF BILL OF QUANTITIES & QUOTED RATES
Total Amount (INR)
(including percent above
Schedule No. & Description Basic Cost (INR) % at Par/above/below
S No / below / at par of
Amount At Par Value)
Section Description of Section In Figure In Words In Figure In Words
Any other items not covered in Schedule A,
14 Schedule-H B1, B2, C1, C2 & D but are required to be
carried out as per direction of Engineer, the
order of preference for adopting rates is as
i) R&B SOR 2023-24
ii) GWSSB SOR 2022-23
(The rate to be paid shall be as per rates
mentioned in above SOR excluding GST)
Total Amount of Schedule A, B1, B2, C1, C2, D, E1, E2, E3,
Total Amount of Schedule A, B1, B2, C1, C2, D, E1, E2, E3,
E4, E5, F, G and H (excluding GST)
01. The tenderer shall quote a percentage (Above/Below/At Par) at SN. 1 to 14 of this summary Sheet only and nowhere else. Total of Schedule from S. No: 1 to
shall be Considered for Tender Evaluation.
02.For the purpose of comparative evaluation of tenders, the amount worked out from the quoted percentage (above/below/at par) or/and quoted rate of item as
applicable, in equivalent INR shall be compared amongst various tenders to determine the lowest evaluated tender applying provision of clause 1.1.3.1 (ix) of NIT.
03. The bidder’s quote to be filled in Annexure – 1 (i.e. Summary Sheet of Bill of Quantity), it should be exclusive of all GST & Custom duties.
04. The tax bifurcation to be filled in Annexure – 2 (i.e. Details of Taxes and Duties.)
GMRC/CONS/DEPOT-2/2026 BOQ
ITEM DESCRIPTION ITEM RATE Quantity Amount (Rs)
1 Conducting GPS survey, fixing the alignment, marking locations, vertical and horizontal clearances, LS 695094.4 1
establishing bench marks, reference lines and control points and other details in consultation with the
Employer’s Representative including corrections if any and approval of Engineer-in-Charge.
i. Digital leveling instrument used for the work shall have minimum accuracy of ±0.3 mm per km double
run with least count not more than 0.01 mm
ii.Total station instrument shall have minimum accuracy for:
a)Angle measurements (Hz, V) of the order of 1". Payment for this item equally distributed over the
duration of the contract and will be paid on pro-rata basis.
GMRC/CONS/DEPOT-2/2026 BOQ
2 Providing and erecting 2.00 metre high temporary barricading at site; each panel of size 2.50mx2.00m RM 2320.26 500
made of 40x40x6mm angle iron or 50x50x3mm hollow MS tube
posts/horizontal members/ bracings covered with 1.63mm thick MS sheet. The sheet shall be fixed with
30x5mm MS flat by suitable welding/riveting. The panels shall be made so that gap of 50cm above the
ground is available making overall height as 2.5m. MS channel ISLC 75 @ 5.70 kg/m, 50cm long shall be
provided at the bottom having oval shaped holes of size 50x25mm at both ends with 50cm long MS
angle 40x40x6mm bracing. Suitable arrangement shall be made to fix the barricading to avoid from
overturning by providing 250mm long expansion fasteners at both ends. The work shall be executed as
per drawing/direction of Engineer-in-Charge which includes writing and painting, arrangement for
traffic diversion such as traffic signals during construction at site for day and night, glow lamps,
reflective signs, marking, flags, caution tape as directed by the Engineer-in-Charge. The barricading
provided shall be retained in position at site continuously i/c shifting of barricading from one location
to another location as many times as required during the execution of the entire work till its completion.
Rate include its maintenance for damages, painting, all incidentals, labour materials, equipments and
works required to execute the job. The barricading shall not be removed without prior approval of
Engineer-in-Charge.
(Note :- One time payment shall be made for providing barricading from start of work till completion of
work i/c shifting wherever necessary. The barricading provided shall remain to be the property of the
contractor on completion of the work).
3 Submit colour photographs of the works as directed by the Engineer and supply with monthly progress Per Set 3284.74 24
report, or as instructed by the Engineer. One set shall comprise of minimum 25 photographs in 3 soft
copy of all photographs on DVD with 3 copies of prints (hard copy) of each photograph of size not less
than 225 x 175 mm each in album form. The phographs chosen should cover important activities of the
work. Photos should have date and time as per Technical Specifications.
4 Supply of Video DVD of 180 minutes duration comprising one master copy and one extra copy as per Per Set 12319.61 24
technical specifications showing the progress of works and methodology and at interval as directed by
Engineer and as per Technical Specifications
GMRC Page 10 of
GMRC/CONS/DEPOT-2/2026 BOQ
5 Providing furnished office at site (Appendix - 2D and Annexure -1 of Employer's Requirement ), for use Per 159125.2 24
of Engineer and his supporting staff at site. Month
6 Drilling 150mm dia boreholes varying from 20m to 40m in all types of soil including mobilisation of RM 2282.6 450
machinery, conducting all SPT. vane shear test, collection of undisturbed and disturbed samples, Soil
Resistivity testing for each borehole, setting up machinery, shifting etc. Including all lab, field tests &
report preparation (pile foundation recommendations including safe pile capacities, pile settlement
calcaulation, etc incorporating all field and laboratory testing) as per IRC: 78/IS codes.
Total for Schedule-A General items
GMRC Page 11 of
GMRC/CONS/DEPOT-2/2026 BOQ
ITEM DESCRIPTION ITEM RATE Quantit Amount
Schedule B1:Civil/Structural Works (NDSR Item)
1 SUB SECTION-1: EARTH WORK
1.1 Excavation for open foundation, in all type of soil, below ground as encountered for all type & thickness,
including dismantling of other structure, dead utilities, sorting out stacking of useful materials and
disposing of excavated stuff within depot area as directed by the engineer with all leads and lift (as
specified below), including all supports (by sheet pile/ shoring / strutting to retain and support the soil/
sloped excavation or other methods) for stability including dewatering, pumping and bailing out of
1.1 a) Upto 1.5 Metre Depth Cum 86.84 58931
1.1 b) From 1.5 Metre to 3.0 Metre Cum 95.98 22721
1.1 c) From 3.0 Metre to 5.0 Metre Cum 105.12 3900
1.1 d) For every extra metre depth beyond 5m .This rate is payable over and above the rate of Rs 115 (for 3 to Cum 9.14 215
5 m mentioned above). e.g for 5 to 6 m depth rate payable will be Rs 125 per cum ,for 6m to 7m depth
rate payable would be Rs 135 per cum ,so on & so forth
1.2 Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers Cum 54.84 82622
not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering as per
Technical specification
1.3 EARTH WORK for embankment including breaking clods dressing with all lead and lift and including
watering rolling and consolidation of subgrade in layers to required dry density including filling the
depressions which occur during the process using power/vibratory roller as per Technical specification
and as directed by the Engineer.
1.3(a) a) By Depot area soil obtained from cutting(suitable soil) Cum 95.98 12900
GMRC Page 12 of
GMRC/CONS/DEPOT-2/2026 BOQ
1.3(b) (b) by Contractor`s own suitable soil broought from outside the depot. The rates are inclusive of Cum 352.86 67500
procurement of materials with all lead, lift , spreading , watering , compacting, contractor`s own
machineries , equipment labour including all taxes , royalities octroi and necessary enviornment
clearence from Centre/State authorities (if any) etc Complete and dressing all slopes and top surfaces to
required level as per Technical Specifications. Note : Source of soil to be approved by Engineer Incharge.
1.4(a) Transplanting the marked trees of various species and girth to the place shown by Engineer-in-
charge/Engineer’s representative within a lead of 1.5km with all tools, plants, man & machinery and
necessary preparation such as preparation of earth ball of tree roots of desired depth & diameters,
dislodging, lifting, transportation and transplanting tree from original place to the new place including
all arrangements, tools & plants, labour etc., for successfully completing the work. The work includes
excavating pits of adequate size, arranging loose soil, mixing of manure, fertilizer, insecticides etc., to
ensure survival of the trees being transplanted. Maintenance of tree i.e., watering, manuring, soil
heaping, spray of insecticides shall be done for one year. All above operations shall be executed as per
Stage wise payment for the work will be as following:
30% after trees transplanted.
40% after sprouting & establishment of trees
30% after completion of maintenance period of one year.
i) Girth upto 30cm Nos 7769.6 15
ii) Girth more than 30cm but upto 50cm Nos 8957.89 10
iii) Girth more than 50cm but upto 75cm Nos 10054.7 10
iv) Girth more than 75cm but upto 1.25m Nos 11151.6 5
v) Girth more than 1.25m but upto 2.4m Nos 13436.8 5
vi) Girth More than 2.4m Nos 16727.4 5
1.4(b) Extra over item no 1.4 (a) (above) for lead more than 1.5 km and upto 5 km for all girth for Per km 457.04 25
transportation (per km)
GMRC Page 13 of
GMRC/CONS/DEPOT-2/2026 BOQ
1.5 Conducting Plate Load Tests at 2.0 mtre to 3.0 mtre depth (Foundation level) from NGL . Test should Each 30968.7 5
continued till 25 mm settlement in normal circumstances and 50 mm in special cases such as dense
gravel, gravel and sand mixture is obtained or failure of the soil whichever as per IS: 1888 or refusal
whichever is earlier
1.6 Uprooting stumps of tree and disposal upto 1.5 km distance
a Girth more than 30cm but upto 60cm Each 914.070 25
b Girth more than 60cm but upto 120cm Each 1096.88 25
c Girth more than 120cm but upto 240cm Each 1371.10 25
d Beyond 240 cm Each 1645.32 25
TOTAL OF SUB SECTION-1: EARTH WORKS
2 SUB SECTION-2: PRECAST REINFORCED CONCRETE
2.1 Providing, casting and fixing precast design mix M30 grade RCC in standard GMRCL RCC boundary wall Cum 9577.58 913.32
panels of required size and thickness of 150mm (or/ and as per design) with shutter finish on one side
and exposed (without shutter) finish on other side including cost of required doses of admixture,
centring and shuttering including form work, shuttering & moulds, laying, compacting by vibration,
transportation of pre-cast reinforced cement concrete wall panels, hoisting and fixing them in position
to correct lines and levels and installed in all stages with necessary scaffolding and putting GMRCL logo
on every 4th panel etc. 40% Payment shall be released on completion of casting and curing to the
satisfaction of the engineer and remaining 60% payment shall be released on the completion of this
work upto the satisfaction of the engineer and as per Technical Specifications. Note: Payment for the
reinforcement of steel will be made separately.(Minimum cement content shall be 340 kg/cum of
concrete). This Item included all temporary support, holding or arrangements of precast panels and
stitching activities including stitching concrete.
GMRC Page 14 of
GMRC/CONS/DEPOT-2/2026 BOQ
2.2 Providing M40 grade reinforced cement concrete (as per techinical specification) for concreting, curing Cum 9497.19 150
precast parapet over Deck slab on both side of viaduct/ramp, including transition span as per the
drawing in all precast psc I-girder/steel girder spans (straight or curved), with all leads. The cost includes
shuttering, scaffolding, special adjustable props for alignment of units, moulds, providing cut outs,
bolts & inserts for fixing signalling mast, curing, required dosage of admixture for concrete, all handling,
and fixing in position, etc. complete) with cast in situ stitch concrete of same grade.Note: Payment at
50% of accepted rate on casting and Balance 50% on completion of erection, stitch concrete and related
works. Rate includes cost of providing grooves/logo of client if required (the ribs/grooves/logo in
shutter if required, shall be as per drawing).Minimum cement content shall be 390 kg/cum of concrete.
Transportation, erection and installation of precast parapets will be paid under separate BOQ item
Section B1 NDSR
2.3 Transportation, erection and installation of precast parapets over already erected superstructure(Box MT 1371.11 375
girder, deck slab) conforming to required lines, grades and dimension complete as per drawings and
specifications including cast in situ stitch concrete of same grade including cast in situ stitch concrete of
same grade. The weight shall be calculated assuming concrete density of 2.5 t/m3. Shifting within the
site/yard is the responsibility of the contractor and shall not be paid separately
2.4 Providing,hoisting and fixing of Precast Reinforced Cement Concrete M30 Grade in tie beams, gutter, Cum 8569.41 1410.4
window, sills/lintels steps of staircase, Trenches of all types, Drain, cable trough, sump and manholes i/c
covers complete cast to profile and the thickness as per approved GFC wherever required as directed by
the engineer.The rate includes cost of all labour, materials and equipment and performing all operations
required for manufacture and transportation of pre-cast reinforced cement concrete items, hoisting and
fixing them in position to correct lines and levels, pointing and finishing, cutting, bending, providing and
fixing of lifting hooks, etc, complete. Note: Payment for the reinforcement of steel will be made
separately. (Minimum cement content shall be 340 kg/cum of concrete)
TOTAL OF SUB SECTION-2: PRECAST REINFORCED CONCRETE
3 SUB SECTION-3: CEMENT CONCRETE WORKS (PLAIN & REINFORCED)
GMRC Page 15 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.1 Providing and laying plain cement concrete M15 grade using OPC/PPC cement for levelling course under Cum 4864.68 6110.82
foundations, pile caps, plinth and tie beams, under floors, basements, under base slabs of water tanks,
bases of platforms, in windows Sills, in filling, holding down bolts, steel columns bases, in fills. or any
other works, including necessary dewatering, formwork, mixing in mechanised batch mix plant,
transporting, compacting, curing and finishing as directed including all leads, lifts, etc. complete as per
approved drawing, specification and as directed by Engineer. Rate shall include preparing surface to
receive PCC, shuttering required dosage of admixute in concrete for obtaining required workability as
per specifications and approval of Engineer-in-charge.
GMRC Page 16 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.2 Providing M-35 grade, reinforced cement concrete (as per specification) using OPC cement confirming
to sulphate concentration criteria as per Sl.No. (i) & (ii) of Table 4 of IS 456 and for high concetration
sulphate content the type of cement shall be used as per Sl. No. (iii), (iv) & (iv) of Table 4 of IS 456, for
open foundations, pile caps, pedestals, plinth beams, foundation tie beams, and other similar works
including excavation through existing concrete/ water bound macadam road / bituminous road /
concrete road /soil/morrum/ hard rock /soft rock/ old structures below ground as encountered of all
thickness including dismantling other structures, dead utilities, dewatering, pumping and bailing out
water, strutting and shoring, curing etc.Minimum cement content shall be 380kg/cum. The item also
includes formwork and backfilling in foundation with quarry dust/sand including watering, compacting
with a vibratory plate compactor. The Cost includes cutting/chipping of pile up to cut off level or up to
good concrete and built up of pile up to required level. The cost includes loading, unloading and disposal
of surplus excavated material along with pile heads using covered trucks to contractor's dumping yard, /
disposal of surplus excavated material at with all leads and lifts and as directed by the Engineer-in-
charge or anyother dumping ground as directed by Engineer within 40 Km of the alignment. The
contractor should ensure that during transportation the carried material does not spill out.
Reinforcement shall be paid separately. Rate shall include cost of using required dosage of admixture in
concrete for obtaining required workability as per approval of Engineer-in-charge. (6% of the amount
shall be withheld. Out of this,3 % of the amount shall be released after disposal of excavated material
including pile head material at contractor's dumping yard and 3 % of the amount shall be released after
restoration works on pile caps). Rate includes restoration of road work over the excavation zone for pile
cap i.e. GSB and WMM over sand filling as per the instruction of the Engineer.
3.2.1 94% on pile Cap casting, 3% on disposal exavted material, 3% on restoration work Cum 6506.35 8500
GMRC Page 17 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.3 Providing and laying M 35 grade reinforced cement concrete (as per specification) for Required to
complete the work at all levels including shuttering scaffolding and all related operations required
to complete the work at all levels including centering, shuttering, propping, staging, scaffolding,
compaction, curing, necessary tools, plants, machinery and all related operations etc.for all heights
using steel material for shuttering & steel props. Form work to be designed in a such way that traffic on
road is allowed during the work at all times. Rate includes cost of providing grooves if required
(the ribs/grooves in pier shutter if required, shall be as per drawing) and sleeves with different
diameters. Reinforcement shall be paid separately. Rate includes cost of using required dosage of
admixture in concrete for obtaining required workability, curing compound as per specification & as
per specifications includes loading, unloading and all complete as per approved drawings and
specifications. The rates shall be inclusive of placing "Y' Shaped angle iron at top of columns / wall for
fencing, however cost of 'Y' Shaped angle iron shall be paid seperatly.
Minimum cement content shall be 380 kg/cum of concrete.
3.3.1 In Trenches of all types, Drains of all types, Manholes of all types, Box Culverts, Catch Basins, Pull Pits, Cum 9375.95 6000
Gully & Grease Trap, Concrete Encasement of all types, Cover slabs, Protection slabs and other similar
works as shown Complete in all respects and as directed by Engineer in charge.
Note: The rates quoted shall be inclusive of foundations, walls, slabs for structures mentioned in item
no: 3.3.1 etc as per drawings and specifications
3.3.2 In Columns, Slabs, Beams (above ground level), Retaining Walls, Toe Walls, Parapet walls, Lintels, Cum 9476.76 5500
Hangers, Posts, Shells and Mullions of all shapes and sizes, Basement Walls, Canpoy, Overhead tanks etc
and other similar works as shown or as directed by Engineer in charge.
3.4 Extra Cost for concrete on item 3.2 and 3.3 above for using M40/20 concrete (cement as per technical Cum 63.07 860
specification) instead of M 35/20 concrete (Minimum cement content shall be 390 kg/cum of
GMRC Page 18 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.5 Providing and laying M-40 grade reinforced cement concrete (as per specification) for Viaduct Ramp Cum 9577.58 1668.4
beams and deck slab including shuttering scaffolding and all related operations required to complete
the work at all levels including centering, shuttering, propping, staging, scaffolding, compaction, curing,
necessary tools, plants, machinery and all related operations etc.for all heights using steel material for
shuttering & steel props. Form work to be designed in a such way that traffic on road is allowed during
the work at all times. Rate includes cost of providing grooves if required (the ribs/grooves in pier
shutter if required, shall be as per drawing). Reinforcement shall be paid separately. Rate
includes cost of using required dosage of admixture in concrete for obtaining required
workability, curing compound as per specification & approval of Engineer in charge. Minimum
cement content shall be 390 kg/cum of concrete. Rate incudes provision of sacrificial formwork of
steel/concrete for casting of slab
3.6 Providing and laying M-40 grade reinforced cement concrete (as per specification) for Viaduct Ramp Cum 8752.23 218.44
piers and Pier cap (standard pier, portal pier, & cantilever pier, Column from concourse slab to
platform level, Pedestals) etc and column for stations including shuttering scaffolding and all related
operations required to complete the work at all levels including centering, shuttering, propping, staging,
scaffolding, compaction, curing, necessary tools, plants, machinery and all related operations etc.for all
heights using steel material for shuttering & steel props. Form work to be designed in a such way that
traffic on road is allowed during the work at all times. Rate includes cost of providing grooves if required
(the ribs/grooves in pier shutter if required, shall be as per drawing). Reinforcement shall be
paid separately. Rate includes cost of using required dosage of admixture in concrete for
obtaining required workability, curing compound as per specification & approval of Engineer in
charge. Minimum cement content shall be 390 kg/cum of concrete.
GMRC Page 19 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.7 Providing M40 grade reinforced cement concrete (as per technical specification) for Dwarf wall (for Cum 11887.4 59.34
Expansion joint) and Stitch concrete for Parapet including centering, steel shuttering, scaffolding and all
related operations as required to complete the work as specified in drawings. Rate includes provision of
sacrificial formwork of steel/concrete. Reinforcement shall be paid separately. Rate includes required
dosage of admixture in concrete for obtaining required workability as per approval of Engineer-in-
charge. (Minimum cement content shall be 390 kg/cum of concrete)
TOTAL OF SUB SECTION-3: CEMENT CONCRETE WORKS (PLAIN & REINFORCED)
4 SUB SECTION-4: :REINFORCEMENT WORKS
4.1 Providing TMT reinforcement steel of Fe-550D Grade conforming to IS1786 (latest) from approved Tonnes 73596.1 3500
list of supplier, cost of material, royalty, transportation, handling, storing, straightening, cutting,
bending, tying, lap/butt welding, placing in position including 18 gauge GI binding wire in diamond form
at each reinforcement junction in all structural concrete at all heights and depths with all leads
complete as directed. Rate shall also include welding involved towards stay current protection
effects as per system approved by Engineer-in- charge. The rate shall also include the cost of binding
wire, labour, all material, tools and plants, all leads, lift etc. as per drawings and technical specification
as directed by Engineer-in-charge. The rate shall also include protective coating as per technical
specifications. This item is applicable for all components of viaduct, station box area and other than
station box area (i.e. entry- exit structures. water tanks, escalator, lift pits, staircases pump house etc)
GMRC Page 20 of
GMRC/CONS/DEPOT-2/2026 BOQ
(i) No laps, joints are permitted in rebars provided in superstructures, piers, portals, pier arm, portal
beams. However, mechanical couplers are to be used without extra cost.
(ii) For pile reinforcement, welding of lap joint shall be without extra cost. Additional rings required for
handling the rebar cage shall be the responsibility of the contractor and shall not be paid separately.
(iii) For other structural members, lap joints are permitted for bar dia < 20 mm, (including
mm), else, mechanical couplers are to be provided, where in rebar ends shall be cold forged with die.
(iv) The cost includes all welding and providing mechanical couplers, all types of laps, standard laps,
chair, spacers, bend deduction as per IS-SP 34 etc., as required and nothing extra is payable on this
v) Steel considered for foundations is 30% (approximately) out of total quantity for the purpose of
processing variation of quantities.
4.2 Supplying and providing welded Wire mesh fabrics per IS :1566 from approved supplier ( minimum yield MT 118829. 53.52
strength of 480 Mpa) ,Straightning ,cutting ,tying and placing in floors of Depot Sheds and/or any other
locations as specified by Engineer-in-charge, as per drawings and specifications
TOTAL OF SUB SECTION-4: :REINFORCEMENT WORKS
5 SUB SECTION-5: :MISCELLANEOUS WORKS
5.1 Supplying, pouring and packing non-shrink grout as per manufacturer's specifications under base Cum 50628.5 15.48
plates of columns,grouting of anchor bolts or any other location specified by The Engineer etc complete
as per approved drawings and specifications, including cost of packing plates.
5.2 Providing and fixing in position approved quality Closed cell Polyethylene foam joint filler boards (25 Sqm 1303.46 716.38
mm thick) at expansion joints of concrete structures, as per drawings and instructions complete
including fixing with adhesives etc to complete the work in all respect as per instruction of engineer-
5.3 Providing and laying of Filter media 600mm thick as directed at the back of retaining walls as per Cum 797.07 2100
Technical Specifications
GMRC Page 21 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.4 Providing and laying weep holes in retaining wall by using PVC pipes of 100mm diameter including RM 134.37 1450
proper grade and joining complete, as per Technical Specifications
5.5 Steel Work welded framed work including cutting, hoisting, fixing in position and applying a priming coat Tonnes 58338.7 7
of red lead paint for 'Y' Shaped angle iron and other structural members etc complete, as per Technical
5.6 Providing , fabricating and erecting structural steel for hand/safety railing and other structural members Tonnes 105118. 17
for viaduct ,Station , Foot over bridge, Staircase etc. including transition span consisting of tubular and
rolled sections profiled to require shape, inserts, plates with welded hold fasts for walk-way, earth
terminal plates, insert plates with welded hold-fasts, internal threaded sleeves including MS bolts
tightened by Torque wrench and primer coat & three coats of enamel paint of approved make and
colour as per specification and drawing, with all lead and lifts and as per the directions of engineer. The
rate includes required surface preparation (sand blasting).
All structural steel shall be Hot Dip galvanized conforming to IS-802 (Part II), IS:5358 and IS:4759. and
the mass of zinc coating shall not be less than 500 g/sq.m.
5.7 Omega seal joint RM 2129.78 92
Providing and installing Omega seal joint conforming to specification incl. provision of edge beams at
end edges of both adjoining precast diaphragm segments, cast in situ units and all related operations as
required to complete the work as specified in specifications.
5.8 Providing and laying approved quality silicon sealant with shore hardness of 22, with a movement Cucm 7.31 25000
accommodation of minimum + 50% of joint width, and having a minimum tensile strength of 1.7 Mpa,
suitable for expansion joints in floors and roofs of buildings.
5.9 Providing and fixing MS bolt of 16mm dia 425 mm long length and threading upto 75mm including using Nos 85.92 4032
suitable fixing arrangment
5.10 Providing and laying cinder concrete in cement 1:15 (1 cement: 15 cinder of 12.5mm nominal gauge) on Cum 2172.75 292.08
terreced roof or sunken slabs, laid to slope compacting ,including cost of materials labour, curing
complete as per specifications
5.11 Supplying and fixing of GI Sheet of 16 Gauge for terrace expansion joint including cutting, screwing, Sqm 1425.04 100
placing in position etc complete
GMRC Page 22 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.12 Painting two coats(excluding priming coat) over new steel and other metal surfaces with enamel paint, Sqm 63.07 766
brushing to give even shade including cleaning the surface of all dirt, dust and other foreign matter etc.
complete, as per Technical Specifications
5.13 Polysulphide sealant
5.13(a) Providing and applying polysulphide sealant in 25mm gap incl back up material in the form of round RM 408.59 285
shape Polyethylene foam at both faces of expansion joint in ramp portion.
5.13(b) Providing and Laying Polysulphide sealant for expansion joint upto 25mm width around the column RM 408.59 3000
using Backer rod etc. in form of round shape polyethylene foam including cleaning the surface and
making it ready to receive the filler material complete as per manufacturer’s specification or equivalent
and as directed by Engineer-in-charge
5.14 Providing and fixing in position PVC water stopper 225mm wide 8mm thick in UG tanks including labour RM 477.14 700
charges for handling and positioning etc. as per specification and directions of engineer with all
necessary fittings, anchors, laps and with all lead and lift.
5.15 Supply and Errection of Porta Cabin for Check Post at Depot No 457035. 1
5.16 Providing and laying water proofing treatment in water tanks/sump pit/Overhead Water Tank with Sqm 468.92 1250
layers of epoxy treatment consisting all structures in depot in all levels.
(Note: Dry film thickness per coat, min., by brush /air / airless spray: (75-125) microns and approved by
Engineer Incharge)
(a) Applying Epoxy putty known as TECHOXY or equivalent Consisting of 1 part Techoxy and 2 parts of
(b) Applying 3 coats of epoxy known as TECHOXY or equivalent
5.17 Providing and laying of filter material underneath pitching in slopes complete as per drawings and Cum 1181.89 100
specifications.
5.18 Steel in Dowel Bar and Tie Rod including craddle, laps etc.complete required as per Drawings MT 39474.1 40
GMRC Page 23 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.19 Providing and fixing G.I. concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre RMT 205.67 1200
openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall
with existing angle iron ‘Y’ shaped placed 2.4m or 3.00 m apart and with 9 horizontal R.B.T. reinforced
barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or
G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced
barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape
(0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately)
5.2 Providing chain link fencing 50mm size of 8guage (as per IS 2721) properly streched b/w rectangular Sqm 822.66 2000
poles (upto 3m height) and fixed with suitable bolts & nuts,the free ends shall be welded to the pole and
block pipe at top and bottom as required including cost of all materials,labour,lead & lifts,cutting,
bending wherever necessary,wastage and lapping etc complete as per diection of the engineer in charge
of work including 2 coats of approved quality paint over one coat of shop paint
5.21 Providing and fixing MS block pipe of 38 mm dia,of heavy guage of 14 including removing the RMT 224.04 6000
bends,cutting the pipe and fixing the pipe in b/w the 2 vertical poles (MS rectangular poles) and spot
welding the chain link with MS block pipe including cost of all materials wastage in cutting,and
scaffolding wherever necessary with all lead and lift as directed by the engineer in charge of work etc
complete including 2 coats of approved quality paint over 1 coat of shop paint
5.22 Providing and laying M 35 grade reinforced cement concrete (as per specification) for Required to
complete the work at all levels including shuttering scaffolding and all related operations required
to complete the work at all levels including centering, shuttering, propping, staging, scaffolding,
compaction, curing, necessary tools, plants, machinery and all related operations etc.for all heights
using steel material for shuttering & steel props. Form work to be designed in a such way that traffic on
road is allowed during the work at all times. Rate includes cost of providing grooves if required
(the ribs/grooves in pier shutter if required, shall be as per drawing) and sleeves with different
diameters. Reinforcement shall be paid separately. Rate includes cost of using required dosage of
admixture in concrete for obtaining required workability, curing compound as per specification & as
per specifications includes loading, unloading and all complete as per approved drawings and
specifications.
Minimum cement content shall be 380 kg/cum of concrete.
GMRC Page 24 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.22 - For Concrete Grade M35/20 for for OH Water Tank wall concrete (height upto 6m from Cum 9113.28 64.98
1(a) formation)(Minimum cement content shall be 380 kg/cum of concrete)
5.22 - For Concrete Grade M35/20 for for OH Water Tank wall concrete (height 6m-18m )(Minimum cement Cum 12339.9 58.62
1(b) content shall be 380 kg/cum of concrete)
5.22 - For Concrete Grade M35/20 for overhaed tank slab (Minimum cement content shall be 380 kg/cum of Cum 13482.5 23.73
TOTAL OF SUB SECTION-5: MISCELLANEOUS WORKS
6 SUB SECTION-6: : PILING WORKS
GMRC Page 25 of
GMRC/CONS/DEPOT-2/2026 BOQ
6.1 Providing and installing cast-in-situ vertical bored piles as per approved good for construction (GFC)
drawing and with M35 grade of concrete (as per specification) using OPC cement confirming to sulphate
concentration criteria as per Sl. No. (i) & (ii) of Table 4 of IS 456 and for high concetration sulphate
content the type of cement shall be used as per Sl. No. (iii), (iv) & (iv) of Table 4 of IS 456, including all
operations such as installation and shifting of piling rig etc, in all type of soil strata/rocky strata along
elevated section. Minimum cement content shall be 380kg/cum. The cost includes the cost of empty
boring wherever required. (Measurement shall be from cut-off level to founding level). The stated
length includes test piles for initial load tests. The item includes disposal of earth, muck, slush released
from piles, top cutted portion of pile at disposal ground for all leads. Reinforcement shall be paid
separately. Rate shall include cost of using required dosage of admixture in concrete for obtaining
required workability as per approval of Engineer in charge. Rate shall includes provision of A class MS
pipes of 50mm outer diameter as per technical specification, minimum 1.0mm thick (light) as per IS
1239M in all piles at the time of casting to be used for cross-hole sonic test. Pipes shall extend from
ground level to bottom of pile where pipe shall be sealed at bottom. Rate includes filling of tubes after
sonic test using standard cement non-shrink mortar before casting of pile cap. The item includes drilling
and socketing in rock at required depth. Idling of rig due to any reason shall not be payable. Bore drilling
shall be done by use of hydraulic rig using temporary casing of required depth and polymer slurry. The
item includes the cost of polymer to be used for stabilisation of bore.Note: 500mm dia/ 750 mm dia
/1000 mm dia multiple pile foundation will be implemented. The lengths of each pile diameter is
indicative only and may vary at Detailed Design stage.
6.1.1 500mm dia piles RM 4536.75 100
6.1.2 750mm dia piles RM 6553.08 9000
6.1.3 1000mm dia piles RM 9232.11 212
GMRC Page 26 of
GMRC/CONS/DEPOT-2/2026 BOQ
6.2 Carrying out static initial vertical load tests as per relevant IS Codes including all arrangements
for measuring deflections and submitting reports as per specifications. This includes making of pile head
ready for testing at the desired level, supporting / reaction arrangement (including reaction
piles/soil/rock anchors, if any) for the kentledge load. Cost of pile to be tested wil be paid in item 6.1.
The test arrangements shall cater for additional 25% above test load)
6.2.1 750 mm dia pile (Test load of 640MT) No 453043. 3
6.2.2 1000 mm dia pile (Test load of 1200MT) No. 809683. 1
6.3 Carrying out static initial lateral load tests as per relevant IS Codes including all arrangements
for measuring deflections and submitting reports as per specification and tender drawing. This
includes making of pile head ready for testing at the desired level, supporting / reaction
arrangement (include reaction piles/ soil/ rock anchors, if any) for the kentledge load. (Cost of test
pile will be paid in item 6.1)
6.3.1 750 mm dia pile (Test load of 50MT) NO 152805. 3
6.3.2 1000 mm dia pile (Test load of 50MT) NO 152805. 1
6.4 Carrying out static initial vertical load tests as per relevant IS Codes including all arrangements
for measuring deflections and submitting reports as per specifications. This includes making of pile head
ready for testing at the desired level, supporting / reaction arrangement (including reaction
piles/soil/rock anchors, if any) for the kentledge load. Cost of pile to be tested wil be paid in item 6.1.
The test arrangements shall cater for additional 25% above test load)
6.4.1 750 mm dia pile (Test load of 380 MT) NO 352858. 4
6.4.2 1000 mm dia pile (Test load of 600 MT) NO 514138. 1
GMRC Page 27 of
GMRC/CONS/DEPOT-2/2026 BOQ
6.5 Carrying out static initial lateral load tests as per relevant IS Codes including all arrangements
for measuring deflections and submitting reports as per specification and tender drawing. This
includes making of pile head ready for testing at the desired level, supporting / reaction
arrangement (include reaction piles/ soil/ rock anchors, if any) for the kentledge load. (Cost of test
pile will be paid in item 6.1 )
6.5.1 750 mm dia pile (Test load of 30MT) NO 174377. 3
6.5.2 1000 mm dia pile (Test load of 30MT) NO 174377. 1
6.6 Providing and fixing permanent MS liner (of required thickness or as directed by Engineer-in-charge) for Tonnes 94137.3 5
500/750/1000 mm dia bored cast-in-situ piles wherever required as per approved construction drawings
and directions of Engineer-in-charge all complete and applying a primer coat of approved steel primer.
Measurement :- The liner shall be of MS plate, of required thickness or as per drawings duly approved.
The payment of liner shall be made in Kg as per the area of the MS sheet provided in liner multiplied by
density (78.5 kN/m3). The quoted rates will be applicable for all lengths provided upto the soffit of pile
cap. The measurement will be made for the actual length of liner provided correct to one centimeter.
TOTAL OF SUB SECTION-6: : PILING WORKS
7 SUB SECTION-7 : PRE ENGINEERED BUILDINGS:
7.1 Designing, providing, fabricating, painting, transporting, erecting (using mechanised erection) and
securing in position structural steel work ,standing seam profiled roof sheeting having provision for
supporting Solar panel ,roof monitor, inspection platform for buildings and workshops complete as per
technical specifications, approved shop drawings and / or instructions.
Work under this item would generally cover
GMRC Page 28 of
GMRC/CONS/DEPOT-2/2026 BOQ
7.1 - (i) All structural steel work in the Buildings, including but not being limited to, columns, stanchions, beams,
rafters, purlins, runners for cladding, gantry girders, brackets, hangers/ suspenders, runner beams for
under slung cranes, bracings, etc. Work to include all intermediate stages of activities not defined
herein, but otherwise implied for total completion of work cost to include but not be limited to, all
materials including wastage, all consumables, fasteners of all types for both temporary and permanent
stages of work, all temporary stays, labour, temporary works including staging, scaffolding, tools, plant
and equipment, and, costs of all incidentals and necessary testing of material, workmanship etc
including cost of painting as per Technical specifications Measurement will be on plan areas along
center lines of exterior rows of columns for individual buildings -
(A) For item 7.1.1 to 7.1.5 -PEB payment shall be on overall plan area basis between considering c/c of
coulmn peripherial area as per technical specification.
(B) Item 7.1.6 PEB payment will be made as per overall plan area, extreme of roof edge.
(C) Payment for Item 7.1 shall be made as follows:
1. 55% on Supply and Delivery of Fabricated Material
2. 45% on Overall Completion and testing
7.1 - (ii) Designing, Providing, fabricating and erecting hot dipped galvanised "Rain Water Gutters'' using
mm thick mild sheets including all accessories, connections sleeves for connecting rain water pipes to
Gutters placed at roof along all valleys and edges of Buildings including site seal welding at all joints to
make water tight including painting as per specifications.
GMRC Page 29 of
GMRC/CONS/DEPOT-2/2026 BOQ
7.1 - (iii) Supplying and fixing of standing seam profiled roof sheeting having provision for supporting Solar panel
with roof sheeting 450-480 cover width with rib height 74-76mm.(Basemetal thickness 0.55 mm) HI
Tensile Galvalume/Zincalume Steel or as aproved with hot dip metallic coating of minimum
gm/sq.m zinc-aluminium alloy coating mass (55% Aluminimum, 43% zinc and 1.5% silicon). Coating mass
total on both sides AZ-150 or equivalent as per AS 1397-1993. Minimum 550 Mpa yield strength with
silicon modified polyester (SMP) coating, (minimum silicon content 30% - 50% or super-polyester XRW
quality paint coat of approved colour. Coating shall be as per AS/NZS-2728-1997, Category-3. Total
coating thickness of 35 microns, comprising of 20 microns exterior coat of SMP over super-polyester
Fixing arrangement - Specially designed roof clips shall be used to hold standing seam roof sheet to the
supporting structural member. The clip is designed to move freely in both directions to take care of
thermal expansion and contraction. Roof Sheet side laps shall be field seamed by roof runner seaming
machine which is self-propelled and portable electricallock-seaming machine. The machine field forms
the final 180 degrees of a 360 degree double-lock standing seam, all side lap sealant shall be factory
applied butyl rubber hot metal sealant. The panel end lap shall be joined by mean of a two piece
clamped connection or similar approved connection consisting of a bottom reinforcing plate and top
panel strap. Screw bolt type fastener shall be used for fixing standing seam roof sheeting clip as per
manufacturer’s specification with approval of The Engineers.
The Contractor shall give a minimum 10 year guarantee to the client for sheets against deterioration,
disintegrationloss of lusture, variation in colour etc. and leakages across laps, fasteners etc.All types of
steel sheets shall be load tested to satisfy 1.10 times the design wind loads and coating thickness to the
satisfaction of the Engineer-in- charge. Fasteners shall also be load tested. The Contractor is to submit
design and shop drawing for sheet profile before installation for approval of The Engineer.
GMRC Page 30 of
GMRC/CONS/DEPOT-2/2026 BOQ
7.1 - (iv) Design, Supply and Erection of Structural steel (conforming to IS:2062 Grade B0) work for inspection
platform using structural sections incl. anchor bolts fabricated /procured to the required profile and
shape as per approved GFC, hoisted, installed in position incl. all cutting, welding (continuous welding
wherever required and directed ) grinding, templates,with adequate temporary supports, scaffolding,
staging, etc. The rate includes all tests on material and fabrication, sand blasting, primer and painting as
per the technical specifications for internal and external surfaces. Every precautions to be taken against
rusting of sections. (Payment shall be on overall plan area of finished work as per technical specification
of the contract.)
7.1 - (v) Plain, 0.55 mm TCT ,SMP coated Galvalume/superpolyster XRW zincalume steel of similar material for
ridge capping pieces at apex of skylights/hips including notching, turning down of edge of capping
between ribs etc. all complete
7.1 - (vi) Providing, supplying, erecting and fixing in position 3mm thk Polycarbonate sheets of approved texture
and colour for roof lighting. Sheets to be profiled to match metal sheets and should include cost of
laying sheets in all profile curvature and shape at all level as per GFC. The rate includes jointing, sealing
with Butyl adhesives and cover all costs of labour tools, plant, staging and temporary works to complete
the work in all respect as per approval of The Engineer.
7.1.1 Inspection Bays including, side roof inspection platform with access (3 Nos) of cantilever and suspended sqm 8468.6 2379.3
from roof type (consisting of plates, rolled sections, chequered plates, tuubes etc), portals, purlins,
runners for cladding, gantry girders, Runway beams, roofing, gutters, stringer support beam (for all
lines) etc. (Support arrangement for EOT crane 1.5t - 2 nos.)
7.1.2 Heavy Cleaning Building / Interior Cleaning Building including ,side roof inspection platform with access sqm 10434.5 1994.47
(consisting of plates,rolled sections,chequered plates,tubes etc) portals, purlins, runners for 2
cladding,roofing, gutters etc.
7.1.3 Workshop Bays including side roof inspection platform with access (4 Nos) of cantilever (consisting of sqm 9325.54 5519.22
plates, rolled sections, chequered plates, tuubes etc), Portals, Purlins, runners for cladding, Gantry
Girder, Runway beams, roofing, gutters etc.(Suppport arrangement for EOT crane 5t-2 nos and EOT
crane 15t/2t - 1 nos at each bays)
7.1.4 Pit Wheel Lathe Building/ Auxillary workshop(ETU) including portals, purlins, runners for cladding sqm 8569.41 2065.5
,Gantry Girders in Pit Wheel Lathe, roofing, gutters etc.(Suppport arrangement for EOT crane 5t -
GMRC Page 31 of
GMRC/CONS/DEPOT-2/2026 BOQ
7.1.5 SBL /Blowdown Plant/ RRV Parking including columns, rafters/trusses, runners, ties, purlins ,roofing, sqm 4788.79 9609.6
gutters etc as shown in drawings or as directed and approved
7.1.6 Car Parking Shed and Scooter/Cycle stand including columns, rafters/trusses, runners, ties, purlins sqm 2240.37 1056
,roofing, gutters etc as shown in drawings or as directed and approved.
NOTE: Providing, fabricating and supplying Hot - Dip Galvanized Holding Down Bolts (As per IS 1367)
including all assemblies and accessories etc that are required to be embedded in concrete work by other
agencies are included in the rate quoted by the tenderer in item nos. 1.1 to 1.8. Bolts shall be of
sufficient length to ensure that a minimum 40mm length of threaded portion is embedded in concrete.
Threaded portion to be left projecting outside the concrete surface shall be as per requirement of
supplier's design and approved drawings.The rate includes cost of supply, testing/ inspection,
fabrication, assembly and supply of bolts as per GFC, costs of all washers, nuts, lock nuts and pins that
may be required for securing the structural member with the embedded bolts. Work of actual fastening
of the structural components with the embedded bolts shall have to be carried out by the supplier of
the steel structure. However the foundation bolts shall be installed in foundation by civil contractor for
construction of depot as per approved GFC and instruction of The Engineer.
7.2 Providing and fixing side wall cladding, gable end cladding of all profile ,level,shape and size etc,.. all
complete as per approved drawing with single skin Hi-rib Profiled sheeting 930-1020 mm cover width
28-30 mm crests @ 186 -333 mm c/c manufactured out of 0.55mm TCT (Basemetal Thickness) Hi-
tensile Galvalume /Zincalume steel. Sheets shall have wide pans with 2-3 nos stiffeneing ribs for
effective water shedding and special male/female ends with full return legs on side laps for purlin
supports and anti-capillary flute in side lap. Sheets shall have hot-dipped metallic Zinc-Aluminum alloy
coating (150 gms / sqm, Zinc 45%, Aluminum 55%). Coating mass total on both sides AZ-150 or
equivalent as per AS 1397-1993. Minimum 550 Mpa yield strength with silicon modified polyester (SMP)
coating, (minimum silicone content 30%-50% or super-polyester XRW quality paint coat of approved
colour. Coating shall be as per AS/NZS-2728-1997, Category-3. Total coating thickness of 35 microns,
comprising of 20 microns exterior coat of SMP over super-polyester XRW on top surface and 5 micron
polyester reverse on back surface over 5 micron primer coats on both surfaces including side and end
GMRC Page 32 of
GMRC/CONS/DEPOT-2/2026 BOQ
Fixing arrangement -The wall cladding Sheets shall be fixed using polymer coated hot dip galvanized hex Sqm 501.82 6456.88
head self drilling fasteners as per AS 3566 clause 3 on each crest of sheets for connection with
purlins/runners as per approval of The Engineer.Approved sealing tapes of approved make shall be used
on side laps and end laps of sheets and closers to be dipped stitching fasteners @ 300 mm c/c on all
sides and end laps etc. Measurement shall be based on per unit of finished / laid surface area. Item to
include curved sheets also whereever provided at the last end of sheets.
The Contractor shall give a minimum 10 year guarantee to the employer for sheets against
deterioration, disintegrationloss of lusture, variation in colour leakages across laps and fasteners etc. All
types of steel sheets shall be tested to satisfy 1.10 times the design wind loads and coating thickness to
the satisfaction of the Engineer- in-charge. Fasteners shall also be load tested. The Contractor is to
submit design and shop drawing for approval on the sheet profile, design and details before installation.
7.3 Supplying and fixing of Galvalume Louver to structural frame work as per drawing detail including all Sqm 1960.68 1028.09
necessary fixtures and structural framework complete as per direction of Engineer in charge. Leaves will
be made by 0.55mm TCT Hi tensile Galvalume sheet with both side stiffening rib . Sheet shall have a hot
dip metallic Zinc & Aluminium alloy coating . Measurement will be on area basis along outermost edge
of frame installed at site.
7.4 Design, Supply of Structural steel (conforming to IS:2062 Grade B) work using structural sections incl. Tonne 112376. 151.07
anchor bolts fabricated /procured to the required profile and shape as called for, hoisted, installed in
position incl. all cutting, welding (continuous welding wherever required and directed ) grinding & all
operations, necessary templates, adequate temporary supports, scaffolding, staging, etc. incl. all tests
on material and fabrication as required. Item to include the cost of sand blasting, primer and painting
internal and external surfaces as per technical specifications of the contract with anti corrosion
treatments as per specification. ( Installation of track,track plates & others fittings /fixtures pertains to
track shall be done by track contractor )
Rail track supporting columns of approximate length of 1210mm of HE240 of Zindal Steel Pvt. Ltd. or
equivelent complete with base plate and capping plate, holding down bolts etc complete in all respect
including any modification or rectification if any to facilitate the Interface ( track and system)
GMRC Page 33 of
GMRC/CONS/DEPOT-2/2026 BOQ
7.5 Providing and fixing Turbovent of 600mm dia complete with FRP base to match roofing sheet, variable No 6839.08 64
angle elbow and flashing waterproofing as required at site and as per technical specifications and
TOTAL OF SUB SECTION-7 : PRE ENGINEERED BUILDINGS WORKS
8.01 Providing, and fixing 150 mm dia rigid PVC Pipe of Class 10 (IS-3076 and 4985) under safety kerb all RMT 137.11 852
complete as per direction of the engineer.
8.02 Construction of Median and Island above road level with approved material brought from borrow pits, Cum 319.92 60
spread, sloped and compacted as per MORT&H "Specifications for Road & Bridge Works" (5th Edition)
8.03 Providing and applying Primer Coat with bitumen emulsion on prepared surface of Granular Base Sqm 14.63 10000
including clearing of road surface and spraying primer at the rate of 0.60 kg/sqm using mechanical
means as per MORTH "Specifications for Road & Bridge Works" (5th Edition) Clause
8.04 Vacuum dewatered concrete M30/20 for grade slabs using Polypropylene fibers at 1.0 kg of fibers per Cum 9140.71 1200
cum of Concrete in floors of Depot sheds as per drawings and technical specifications
TOTAL OF ROAD WORKS
Total for Schedule B1:Civil/Structural Works (NDSR Item)
GMRC Page 34 of
GMRC/CONS/DEPOT-2/2026 BOQ
ITEM DESCRIPTION ITEM RATE (Rs) Quantity Amount
Schedule B2:Civil/Structural Works (DSR Item)
1 SUB SECTION-1: EARTH WORK
1.1 Supplying and filling in plinth with sand under floors, including Cum 1739.62 911
watering, ramming, consolidating and dressing complete.
1.2 Clearing jungle including uprooting of rank vegetation, grass,brush Sqm 10.86130994 146872
wood, tress and saplings of girth upto 30 cm measured at a height
of 1m above ground level and removal of rubbish upto a distance
of 50 m outside the periphery of the area cleared.
1.3 Cutting/Felling trees of the girth(measured at a height of 1m
above ground level), including cutting of trunks and branches,
removal and uprooting the stumps & roots and stacking of
serviceable material and disposal of unserviceable material.
a Beyond 30 cm girth upto and including 60 cm girth Each 339.4159357 35
b Beyond 60 cm girth upto and including 120cm girth Each 1509.722082 90
c Beyond 120 cm girth upto and including 240 cm girth Each 7002.829586 40
d Above 240 cm girth Each 14031.90734 25
1.4 Disposal of building rubbish / malba / similar unserviceable, Cum 124 50
dismantled or waste materials by mechanical means, including
loading, transporting, unloading to approved
municipal dumping ground or as approved by Engineer-in-charge,
beyond 50 m initial lead, for all leads including all lifts involved.
TOTAL OF SUB SECTION-1: EARTH WORK
2 SUB SECTION-2: PILING WORKS
GMRC Page 35 of
GMRC/CONS/DEPOT-2/2026 BOQ
2.1 Integrity testing of Pile using Low Strain/ Sonic Integrity Test/ Sonic No 836.32 375
Echo Test method in accordance with IS 14893 including surface
preparation of pile top by removing soil, mud, dust & chipping lean
concrete lumps etc. and use of computerised equipment and high
skill trained personal for conducting the test & submission of
results, all complete as per direction of Engineer-in-charge.
Note :- The inclusion of the above item in the schedule of work Per test
shall be judiciously decided by the technical sanctioning authority,
keeping in view the quality control, type of soil strata &
importance of the project.
TOTAL OF SUB SECTION-2: PILING WORKS
3 SUB SECTION-3: MISCELLANEOUS WORKS
3.1 Steel work welded in built up sections/ framed work, including
cutting, hoisting, fixing in position and applying a priming coatof
approved steel primer using structural steel etc.as required
3.1.1 In stringers, treads, landings etc. of stair cases,including use of MT 83432.96 33.96
chequered plates wherever required, all complete
3.1.2 In gratings, frames, guard bar, ladder, railings, brackets, gates MT 116707.49 47.56
and similar works
3.2 Structural Steel work in single section, fixed with or without MT 76661.84 5
connecting plate including cutting, hoisting, fixing in position and
applying a priming coat of approved steel primer all complete
3.3 Structural steel work riveted, bolted or welded in built up sections, MT 90649.4 5
trusses and framed work including cutting, hoisting, fixing in
position and applying a priming coat of approved steel primer all
3.4 Finishing with Epoxy paint (two or more coats) at all locations Sqm 169.26 11704
preparedand applied as per manufacturer’s specifications
including appropriatepriming coat, preparation of surface, etc.
complete. On all types of steel work
Note: Punched tape concertina coil 600 mm dia shall be of Hot dip
GMRC Page 36 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.6 Dry stone pitching 22.5 cm thick including supply of stones and Sqm 650.77 50
preparing surface complete.
3.7 Providing and fixing thermal insulation of ceiling (under deck Sqm 486.95 15840
insulation) with Resin Bonded Rockwool conforming to IS:
8183,density 48 kg/ m3, 50 mm thick, wrapped in 200 G Virgin
Polythene bags fixed to ceiling with metallic cleats (50x50x3 mm)
@ 60 cm and wire mesh of 12.5mm x 24 gauge wire mesh, for top
most ceiling of building.
TOTAL OF SUB SECTION-3: MISCELLANEOUS WORKS
4 SUB SECTION-4: WATER PROOFING WORK
4.1 Providing and applying integral crystalline slurry of hydrophilic in Sqm
nature for waterproofing treatment to the RCC structures like
retaining walls of the basement, water tanks, roof slabs, podiums,
reservior, sewage & water treatment plant, tunnels / subway and
bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and
: 1 (3 parts integral crystalline slurry : 1 part water) for horizontal
surfaces and applying the same from negative (internal) side with
the help of synthetic fiber brush. The material shall meet the
requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control
concrete as per DIN 1048 and resistant to 16 bar hydrostatic
pressure on negative side. The crystalline slurry shall be capable of
self-healing of cracks up to a width of 0.50mm.
The work shall be carried out all complete as per pecification and
the direction of the engineer-in-charge. The product performance
shall carry guarantee for 10 years against any leakage.
For vertical surface two coats @ 0.70 kg per sqm Sqm 414.54 1812
For horizontal surface one coat @1.10 kg per sqm. Sqm 414.54 1812
GMRC Page 37 of
GMRC/CONS/DEPOT-2/2026 BOQ
4.2 Providing and laying water proofing treatment in sunken portion Sqm 1246.34 767
of WCs, bathroom etc., by applying cement slurry mixed with
water proofing cement compound consisting of applying :
a)First layer of slurry of cement @ 0.488 kg/sqm mixed
with water proofing cement compound @ 0.253 kg/ sqm. This
layer will be allowed to air cure for 4 hours.
b)Second layer of slurry of cement @ 0.242 kg/sqm mixed with
water proofing cement compound @ 0.126 kg/sqm. This layer will
be allowed to air cure for 4 hours followed with water curing for
48 hours. The rate includes preparation of surface, treatment
and sealing of all joints, corners, junctions of pipes and
masonry with polymer mixed slurry.
TOTAL OF SUB SECTION-4: WATER PROOFING WORK
5 SUB SECTION-5: ROAD WORK
SUB-BASES & SHOULDERS
5.1 Construction of granular sub-base by providing close graded Cum 2220.65 22000
Material conforming to specifications, mixing in a mechanical mix
plant at OMC, carriage of mixed material by tippers to work site,
for all leads & lifts, spreading in uniform layers of specified
thickness with motor grader on prepared surface and compacting
with vibratory power roller to achieve the desired density,
complete as per specifications and directions of Engineer-in-
Charge. With material conforming to Grade-I (size range 75 mm to
0.075 mm) having CBR Value-30
5.2 Providing, laying, spreading and compacting graded stone Cum 2353.28 6860.48
aggregate (size range 53mm to .075mm) to Wet mix macadam
(WMM) specification including premixing the material with water
at OMC in for all leads and lifts laying in uniform layers with
mechanical paver finisher in sub-base/base course on well
prepared surface and compacting with vibratory roller of 8 to
tonne capacity to achieve the desired density, complete as per
technical specifications and directions of Engineer in Charge
GMRC Page 38 of
GMRC/CONS/DEPOT-2/2026 BOQ
BITUMINOUS WORKS
5.3 Providing and applying Tack coat using bitumen emulsion
conforming to IS: 8887, using emulsion pressure distributer
including preparing the surface & cleaning with mechanical
broom With medium setting bitumen emulsion
5.3.1 On W.B.M / W.M.M. @ 0.4kg/sqm Sqm 14.8 41994.08
5.3.2 On bituminous surface @ 0.25kg/sqm Sqm 9.82 25654.08
5.4 Providing and laying Dense Graded Bituminous Macadam using
crushed stone aggregates of specified grading, premixed with
bituminous binder and filler, transporting the hot mix to work site
by tippers, laying with paver finisher equiped with electronic
sensor to the required grade, level and alignment and rolling with
smooth wheeled, vibratory and tandem rollers as per
specifications to achieve the desired compaction and density,
complete as per specificatons and directions of Engineer-in-
5.4.1 50 to 100 mm average compacted thickness with bitumen of Cum 8966.01 2713.91
grade VG-30 @5% (percentage by weight of total mix) and
lime filler @ 2% (percentage by weight of Aggregate) prepared
in Batch Type Hot Mix Plant of 100-120 TPH capacity.
5.5 Providing and laying Bituminous concrete using crushed stone
aggregatesof specified grading, premixed with bituminous binder
and filler, transportingthe hot mix to work site by tippers, laying
with paver finisher equiped withelectronic sensor to the required
grade, level and alignment and rolling with smooth wheeled,
vibratory and tandem rollers to achieve the desiredcompaction
and density as per specification, complete and as per directionsof
Engineer-in-Charge.
GMRC Page 39 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.5.1 40/50 mm compacted thickness with bitumen of grade VG-30 Cum 9750.74 1026.16
@5.5% (percentage by weight of total mix) and lime filler @
3% (percentage by weight of Aggregate)prepared in Batch Type
Hot Mix Plant of 100- 120 TPH capacity.
5.6 Providing and laying design mix cement concrete of M-30 grade, in
roads/ taxi tracks/ runways, using cement content as per design
mix, using coarse sand and graded stone aggregate of 40 mm
nominal size in appropriate proportions as per approved &
specified design criteria, providing dowel bars with sleeve/ tie bars
wherever required, laying at site, spreading and compacting
mechanically by using needle and surface vibrators, levelling to
required slope/ camber, finishing with required texture, including
steel form work with sturdy M.S. channel sections, curing, making
provision for contraction/ expansion, construction & longitudinal
joints (10 mm wide x 50 mm deep) by groove cutting machine,
providing and filling joints with approved joint filler and sealants,
complete all as per direction of Engineer-in-charge (Item of joint
fillers, sealants, dowel bars with sleeve/ tie bars to be paid
Note:- Cement content considered in M-30 is @ 340 kg/cum.
Excess/ less cement used as per design mix is payable/
recoverable separately.
5.6.1 Cement concrete manufactured in automatic batching plant (RMC Cum 8155.03 798
plant) i/c transportation to site in transit mixer.
GMRC Page 40 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.7 Construction of dry lean cement concrete sub base over a Cum 3458.42 399
prepared sub-grade with coarse and fine aggregate conforming to
IS:383, the size of coarse aggregate not exceeding 25 mm,
aggregate cement ratio not to exceed 15:1, aggregate gradation
after blending to be as per specifications, cement content not to
be less than 150 Kg/cum, optimum moisture content to be
determined during trial length construction, concrete strength not
to be less than 10 Mpa at 7 days, mixed in a batching plant,
transported to site, for all leads & lifts, laid with a mechanical
paver, compacting with 8-10 tonne vibratory roller, finishing and
curing etc. complete as per direction of
Engineerin- charge.
TOTAL OF SUB SECTION-5: ROAD WORKS
Total for Schedule B2:Civil/Structural Works (DSR Item)
GMRC Page 41 of
GMRC/CONS/DEPOT-2/2026 BOQ
ITEM DESCRIPTION ITEM UNIT RATE (Rs) Quantity Amount
Schedule C1: SUB SECTION-1 : BRICK WORKS (DSR Item)
1 SUB SECTION-1 : BRICK WORKS
1.1 Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class Sqm 764.24 100
designation 7.5 in superstructure above plinth level upto floor V level. Cement
mortar 1:4 (1 cement :4 coarse sand)
1.2 Brick work with common burnt clayF.P.S. (non modular) bricks of class designation Cum 5444.1 100
7.5 in superstructure above plinth level up to floor V level in all shapes and sizes in
Cement mortar 1:4 (1 cement : 4 coarse sand)
1.3 Extra for providing and placing in position 2 Nos 6mm dia. M.S. bars at every third Sqm 65.84 100
course of half brick masonry.
1.4 Providing and laying autoclaved aerated cement blocks masonry with 100 mm Cum 6553.08 3667
thick AAC blocks strength not less than 4N/mm2(as per IS :6041) in super structure
above plinth level up to floor V level in cement mortar 1:4 (1 cement : 4 coarse
sand). The rate includes providing and placing in position 2 Nos 6 mm dia M.S. bars
at every third course of masonry work.
TOTAL OF SUB SECTION-1 : BRICK WORKS
2 SUB SECTION-2 : STONE WORK
GMRC Page 42 of
GMRC/CONS/DEPOT-2/2026 BOQ
2.1 Providing and fixing 18 mm thick gang saw cut, mirror polished granite,
premoulded and prepolished, machine cut for kitchen platforms, vanity counters,
window sills, facias and similar locations, of required size,approved shade, colour
and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse
sand), joints treated with white cement, mixed with matching pigment, epoxy
touch ups,including rubbing, curing, moulding and polishing to edges to give high
gloss finish etc. complete at all levels (Granite of any colour and shade as approved
by Engineer)For
area of slab over 0.50 sqm. Sqm 3287.83 325.59
area of slab Upto 0.50 sqm. Sqm 3287.83 50
2.2 Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., meter 349.08 714.97
including machine polishing to edge to give high gloss finish etc. complete as per
design approved by Engineer-in-Charge.
2.3 Extra for fixing marble / granite stone, over and above corresponding basic item, in meter 355.87 294.9
facia and drops of width upto 150 mm with epoxy resin based adhesive, including
cleaning etc. complete.
2.4 Extra for providing opening of required size & shape for wash basin/ kitchen sink in Each 602.56 9
kitchen platform, vanity counter and similar location in marble/ granite/ stone
work, including necessary holes for pillar taps etc. including moulding, rubbing and
polishing of cut edges etc. complete.
2.5 Providing and fixing stone slab table rubbed, edges rounded and polished of size
1350x600 mm deep and 18 mm thick fixed in urinal partitions by cutting a chase of
appropriate width with chase cutter and embedding the stone in the chase with
epoxy grout or with cement concrete 1:2:4 (1cement 2 coarse sand 4 grade stone
aggrigate 6mm nominal size) as per direction of Engineer in charge and finished
2.5.1 Granite stone of approved shade Sqm 2638.6 19
GMRC Page 43 of
GMRC/CONS/DEPOT-2/2026 BOQ
TOTAL OF SUB SECTION-2 : STONE WORK
3 SUB SECTION-3 : METAL WORK
3 Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene
gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as
per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
3-(a) Polyester powder coated aluminium (minimum thickness of polyester powder Kg 380.87 390.77
coating 50 micron)
Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I)
decorative type, core of block board construction with frame of 1st class hard
wood and well matched teak 3 ply veneering with vertical grains or cross bands
and face veneers on both faces of shutters.
3-(b) including 35 mm thick including ISI marked Stainless Steel butt hinges with Sqm 2572.01 348.73
necessary screws
3-(c) Extra for providing lipping with 2nd class teak wood battens 25 mm minimum Sqm 334.53 348.73
depth on all edges of flush door shutters (over all area of door shutter to be
GMRC Page 44 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.1 Providing and fixing aluminium work for doors, windows, ventilators and partitions
with extruded built up standard tubular sections/ appropriate Z sections and other
sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash
fasteners of required dia and size, including necessary filling up the gaps at
junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene
gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and
jointed mechanically wherever required including cleat angle, Aluminium snap
beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as
per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) :
3.1-(a) For fixed portion Polyester powder coated aluminium (minimum thickness of Kg 380.87 390.77
polyester powder coating 50 micron):
3.1-(b) For shutters of doors, windows & ventilators including providing and fixing Kg 455.05 1827.73
hinges/pivots and making provision for fixing of fittings wherever required
including the cost of EPDM rubber / neoprene gasket required (fittings shall be
paid for separtely) Polyester powder coated aluminium (minimum thickness of
polyester powder coating 50 micron)
3.2 Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating
not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour
or shade with necessary screws etc. complete
3.3 Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 Each 661.73 164
levers and a pair of lever handles of approved quality with necessary screws etc.
GMRC Page 45 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.4 Providing and fixing aluminium round shape handle of outer dia 100 mm with SS Each 68.34 200
screws etc. complete as per direction of Engineer-in-Charge. Powder coated
minimum thickness 50 micron aluminium.
3.5 Providing and fixing stainless steel (SS 304 grade) adjustable friction windows stays Each 210.02 522
of approved quality with necessary stainless steel screws etc. to the side
hung windows as per direction of Engineer-in-Charge complete. Size 205 mm X
3.6 Providing and fixing 50 mm thick glazed fire resistant door shutters of 60 minutes Sqm 5058.01 272.05
fire rating conforming to IS:3614 (Part-II), tested and certified as per laboratory
approved by Engineer-in-charge, with suitable mounting on door frame, consisting
of vertical styles, lock rail, top rail 100 mm wide, bottom rail 200 mm wide, made
out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/ m2) duly filled FR
insulation material and fixing with necessary stainless steel ball bearing hinges of
approved make, including applying a coat of approved fire resistant primer etc. all
complete as per direction of Engineer-incharge . (panneling to be paid for
GMRC Page 46 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.6 (a) Providing and fixing glazing in fire resistant door shutters, fixed panels & partitions Sqm 29988.02 4
etc., with G.I. beading made out of 1.6 mm thick G.I.sheet (zinc coating not less
than 120 gm/m2) of size 20 x 33 mm screwed with M4 x 38 mm SS screws at
distance 75 mm from the edges and 150 mm c/c , including applying a coat of
fire resistant primer/powder coating of not less than 30 micron on G.I. beading, &
special ceramic tape of 5 x 20 mm size etc complete in all respect as per NBC
IS 16231 (Part 3):2016 and as per direction of Engineer-in-charge with glass of
thickness having 60 minutes of fire resistance both integrity & radiation control
(EW60) and minimum 20 minutes of insulation (EI20). The manufacturer have to
give test report/certification of fire glass and the glass should have the stamp
showing the value of E, EW & EI. The glass shall be tested in approved NABL
accredited lab or by any other accreditation body which operates in accordance
with ISO/IEC 17011 and accredits labs as per ISO/IEC 17025 for testing and
calibration scopes shall be eligible. The maximum glazing size shall not be more
than 1100x2200 mm (w x h) or 2.42 sqm.
3.7 Providing and fixing aluminium extruded section body tubular type universal Each 698.4 317
hydraulic door closer (having brand logo with ISI, IS : 3564, embossed on the body,
door weight upto 36 kg to 80 kg and door width from 701 mm to 1000 mm), with
double speed adjustment with necessary accessories and screws etc. complete.
3.8 Providing and fixing panic bar / latch (Double point) fitted with a single body, Trim Each 5853.09 94
Latch & Lock on back side of the Panic Latch of reputed brand and manufacture to
be approved by the Engineer- in- charge, all complete.
GMRC Page 47 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.9 Providing and fixing 12 mm thick frameless toughened glass door shutter of Sqm 3648.7 12.3
approved brand and manufacture, including providing and fixing top & bottom
pivot & double action hydraulic floor spring type fixing arrangement and making
necessary holes etc. for fixing required door fittings, all complete as per direction
of Engineer-incharge (Door handle, lock and stopper etc.to be paid separately)
3.1 Providing and fixing glazing in aluminium door, window, ventilator shutters and Sqm 1063.44 931.38
partitions etc with EPDM rubber/neoprene gasket etc complete as per the
archtectural drawings and the directions of engineer-in-charge (Cost of aluminium
snap beading shall be paid in basic item): With float glass panes of 5 mm thickness
(weight not less than 12.50 kg/ sqm)
3.11 Providing and fixing 50 cm long aluminium kicking plate of size 100x3.15 mm, Each 173.35 482
anodised (anodic coating not less than grade AC 10 as per IS :1868), transparent or
dyed to required colour or shade, with necessary screws etc. complete.
3.12 Providing and fixing bright finished brass hanging type floor door stopper with Each 87.51 528
necessary screws, etc. complete.
3.13 Providing and fixing hand rail of approved size by welding etc. to steel ladder
railing, balcony railing, staircase railing and similar works, including applying
priming coat of approved steel primer.
GMRC Page 48 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.14 Providing and fixing fire resistant door frame of section 143 x 57 mm having built meter 1185.12 70
in rebate made out of 16 SWG G.I. sheet (zinc coating not less than 120 gm/sqm)
duly filled with vermuculite based concrete mix, suitable for mounting 60 minutes
fire rated door shutters. The frame is fitted with intumuscent fire seal strip of size
10x4 mm (minimum) around the frame and fixing with dash fastener of approved
size and make, including applying a coat of approved brand fire resistant primer
etc. complete as per direction of Engineer-in-charge (Dash fastener to be paid for
TOTAL OF SUB SECTION-3 : METAL WORK
4 SUB SECTION-4 : STEEL WORKS
4.1 Supplying and fixing rolling shutters of approved make, made of required size M.S. Sqm 2300.23 615.07
laths, interlocked together through their entire length and jointed together at the
end by end locks, mounted on specially designed pipe shaft with brackets, side
guides and arrangements for inside and outside locking with push and pull
operation complete, precoated with protective paints, including the cost of
providing and fixing necessary 27.5 cm long wire springs manufactured from high
tensile steel wire of adequate strength conforming to IS: 4454 - part 1 and M.S. top
cover of required thickness for rolling shutters. 80x1.20 mm M.S. laths with
mm thick top cover.
4.3 Extra for providing mechanical device chain and crank operation for operating Sqm 548.39 615.07
rolling shutters . Exceeding 16.80 sqm in area
4.4 Providing and Fixing Ball bearing for rolling shutters Each 344.2 86
GMRC Page 49 of
GMRC/CONS/DEPOT-2/2026 BOQ
4.5 Providing and fixing stainless steel ( Grade 304) railing made of Hollow tubes,
channels, plates etc.,including welding, grinding, buffing, polishing and making
curvature (wherever required) and fitting the same with necessary stainless steel
nuts and bolts complete, i/c fixing the railing with necessary accessories &
stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top
of the floor or the side of waist slab with suitable arrangement as per approval
of Engineer-in-charge, (for payment purpose only weight of stainless steel
members shall be considered excluding fixing accessories such as nuts, bolts,
fasteners etc.).
a) Straight : Kg 471.71 3373.36
b) Curved /Spiral Kg 471.71 178.91
TOTAL OF SUB SECTION-4 : STEEL WORKS
5 SUB SECTION-5 : FLOORING WORKS
5.1 Providing and fixing 1st quality ceramic glazed wall tiles conforming to IS : 15622 Sqm 845.09 487.12
(thickness to be specified by the manufacturer), of approved make, in all colours,
shades except burgundy, bottle green, black of any size as approved by Engineer-
in-Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement
mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg
per sqm, including pointing in white cement mixed with pigment of matching
shade complete.
GMRC Page 50 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.2 Providing and fixing removable raised/false access flooring with system and its
components of approved make for different plenum height with possible height
adjustment upto 50 mm, comprising of modular load bearing floor panels
supported on G.I. rectangular stinger frame work and G.I. Pedestal etc. all
complete, as per the architectural drawings, as specified and as directed by
Engineer-in-charge consisting of : a) Providing at required spacing to form modular
framework, pedestals made out of GI tube of thickness minimum 2 mm and
mm outer diameter, fully welded on to the G.I. Base plate of size
100mmx100mmx3mm at the bottom of the pedestal tube, G.I. pedestal head of
size 75mmx75mmx3.5 mm welded with GI fully threaded stud 16mm outer
diameter with two GI Check nuts screwed on the stud for level adjustment upto
50mm, locking and stabilizing the pedestal head in position at the required level.
The pedestals shall be fixed to the subfloor (base) through base plate using epoxy
based adhesive of approved make or the machine screw with rawl plug.
b) Stringers system in all steel construction hot dipped galvanized of rectangular
size 570x20x30x0.80mm thick having holes at both ends for securing the stringers
on to the pedestal head using fully threaded screws ensuring maximum lateral
stability in all directions, the grid formed by the pedestal and stringer assembly
shall receive the floor panel, this system shall provide adequate solid, rigid support
for access floor panel, the system shall provide a minimum clear uninterrupted
clearance between the bottom of the floor for electrical conduits and wiring etc.
all complete as per the architectural drawings, as specified and as directed by the
Engineer-in-charge.
GMRC Page 51 of
GMRC/CONS/DEPOT-2/2026 BOQ
c) Providing and fixing Access Floor panel of 600x600x32 mm medium grade Filled
Steel anti static high pressure Lamination of 800H grade (FS800H). Access Floor
panel shall be steel welded construction with an enclosed bottom pan with
uniform pattern of 64 hemispherical cones. The top and bottom plates of Steel
Gauges: top 0.6 mm and bottom 0.7 mm fused spot welded together (minimum
welds in each dome and 20 welds along each flange). The panel should be
Corroresist epoxy coated for lifetime rust protection and cavity formed by the top
and bottom plate is filled with Pyrogrip non combustible Portland cementitious
core mixed with lightweight foaming compound. The access floor shall be factory
finished with Antistatic High Pressure laminate with Non Warp technology upto
1mm thickness for superior adhesion and Surface flatness within 0.75mm.The
panel is to withstand a Concentrated Load of 363 kgs applied on area 25mm x
25mm without collapse in the centre of the panel which is placed on four steel
blocks. The panel will withstand and Uniformly Distributed Load (UDL) minimum
1250 kg/sqm and an impact load of 50kg all complete as per the approved
manufacturers specification and as per the direction of Engineer-in-charge. All
specification must be printed on the side of the panel to ensure the quality of the
a) 450 mm Finished Floor Height (FFH): Sqm 4400.44 332.86
b) 300 mm Finished Floor Height (FFH) Sqm 4245.51 126
GMRC Page 52 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.3 52 mm thick cement concrete flooring with concrete hardener topping, under Sqm 645.9 4370.89
layer 40 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand : 4 graded
stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener
consiting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm
nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of
cement or as per manufacturer's specifications. This includes cost of cement
slurry, but excluding the cost of nosing of steps etc. complete
5.4 Cement plaster skirting upto 30 cm height, with cement mortar 1:3 (1 cement: 3 Sqm 427.54 293
coarse sand), finished with a floating coat of neat cement. 18 mm thick
5.7 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be Sqm 760.08 512.76
specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved
make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick
cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @
3.3 kg/sqm including pointing the joints with white cement and matching pigment
etc., complete.
5.8 Providing and laying factory made chamfered edge Cement Concrete paver blocks Sqm 781.75 5088.49
in footpath, parks, lawns, drive ways or light traffic parking etc, of required
strength, thickness & size/ shape, made by table vibratory method using PU
mould, laid in required colour & pattern over 50mm thick compacted bed of sand,
compacting and proper embedding/laying of inter locking paver blocks into the
sand bedding layer through vibratory compaction by using plate vibrator, filling the
joints with sand and cutting of paver blocks as per required size and pattern,
finishing and sweeping extra sand. complete all as per direction of Engineer-in-
Charge.80 mm thick C.C. paver block of M-30 grade with approved color design
GMRC Page 53 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.9 Providing and fixing 10 mm thick acid and / or alkali resistant tiles of approved
make and colour using acid and /or alkali resisting mortar bedding and joints filled
with acid and / or alkali resisting cement as per IS:4457 complete as per the
direction of Engineer-in-charge.
a) In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement: 4 coarse Sqm 1226.79 323.68
b) In dado/skirting on 12 mm thick mortar 1:4 (1 acid proof cement: 4 coarse sand).: Sqm 1318.47 13.36
5.10 Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with Sqm 1256.79 2645.91
grey cement slurry mixed with pigment to match the shade of the slab, including
rubbing and polishing complete with base of cement mortar 1: 4 (1 cement :
coarse sand) : 25 mm thick
5.11 Kota stone slabs 20 mm thick in risers of steps, skirting, dado and pillars laid on 12 Sqm 1485.15 229.96
mm (average) thick cement mortar 1:3 (1 cement : 3 coarse sand) and jointed with
grey cement slurry mixed with pigment to match the shade of the slabs, including
rubbing and polishing complete.
5.12 Providing 10 mm thick plaster of Paris (gypsum anhydrous) ceiling up to a height of Sqm 1184.49 100
5 m above floor level, over first class kail wood strips 25x6 mm with 10 mm gap in
between and reinforced with rabbit wire mesh fixed to wooden frame (frame work
to be paid separately):
TOTAL OF SUB SECTION-5 : FLOORING WORKS
6 SUB SECTION-6 : FINISHING WORKS
6.1(a) 15 mm cement plaster on the rough side of single or half brick wall of mix: 1:4 (1 Sqm 252.53 16604.16
cement : 4 fine sand)
6.1(b) Extra for providing and mixing water proofing material in cement plaster work in per bag of 49.17 2047.23
proportion recommended by the manufacturers. 50kg
GMRC Page 54 of
GMRC/CONS/DEPOT-2/2026 BOQ
6.2 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand) Sqm 219.19 23287.83
6.3 6 mm cement plaster of mix: 1:3 (1 cement : 3 fine sand) Sqm 186.69 9986.02
6.4 Wall painting with acrylic emulsion paint of approved brand and manufacture to Sqm 105.84 32518.49
give an even shade: Two or more coats on new work
6.5 Painting with synthetic enamel paint of approved brand and manufacture of Sqm 145.01 5218
required colour to give an even shade: Two or more coats on new work over an
under coat of suitable shade with ordinary paint of approved brand and
6.6(a) Finishing walls with textured exterior paint of required shade: New work (Two or Sqm 190.02 14177
more coat applied @ 3.28 ltr/10 sqm over and including priming coat of exterior
primer applied @ 2.20 kg/10 sqm)
6.6(b) Finishing walls with Acrylic Smooth exterior paint of required shade, new work Sqm 139.06 12000
(Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of
exterior primer applied @ 2.20 kg/10 sqm)
GMRC Page 55 of
GMRC/CONS/DEPOT-2/2026 BOQ
6.7 Designing, fabricating, testing, protection, installing and fixing in position semi
(grid) unitized system of structural glazing (with open joints) for linear as well as
curvilinear portions of the building for all heights and all levels, including: a)
Structural analysis & design and preparation of shop drawings for the specified
design loads conforming to IS 875 part III (the system must passed the proof test at
1.5 times design wind pressure without any failure), including functional design of
the aluminum sections for fixing glazing panels of various thicknesses, aluminium
cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps
etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-
smoke seals, microwave cured EPDM gaskets for water tightness, pressure
equalisation & drainage and protection against fire hazard including:b) Fabricating
and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5
brackets of required sizes, sections and profiles etc. to accommodate
Dimentional movement for achieving perfectverticality and fixing structural glazing
system rigidly to the RCC/ masonry/structural steel framework of building
structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent
bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the
required capacity and in required numbers.
GMRC Page 56 of
GMRC/CONS/DEPOT-2/2026 BOQ
c) Providing and filling, two part pump filled, structural silicone sealant and one
part weather silicone sealant compatible with the structural silicone sealant of
required bite size in a clean and controlled factory / work shop environment
,including double sided spacer tape, setting blocks and backer rod, all of approved
grade, brand and manufacture, as per the approved sealant design, within and all
around the perimeter for holding glass.d) Providing and fixing in position flashings
of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required
as per the site conditions, to seal the gap between the building structure and all its
interfaces with curtain glazing to make it watertight. e) Making provision for
drainage of moisture/ water that enters the curtain glazing system to make it
watertight, by incorporating principles of pressure equalization, providing suitable
gutter profiles at bottom (if required), making necessary holes of required sizes
and of required numbers etc. complete. This item includes cost of all inputs of
designing, labour for fabricating and installation of aluminium grid, installation of
glazed units, T&P, scaffolding and other incidental charges including wastages etc.,
enabling temporary structures and services, cranes or cradles etc. as described
above and as specified. The item includes the cost of getting all the structural and
functional design including shop drawings checked by a structural designer, dully
approved by Engineer-in-charge.The item also includes the cost of all mock ups at
site, cost of all samples of the individual components for testing in an approved
laboratory, field tests on the assembled working structural glazing as specified,
cleaning and protection till the handing over of the building for occupation. In
the end, the Contractor shall provide a water tight structural glazing having all the
performance characteristics etc. all complete as required, as per the Architectural
drawings, as per item description, as specified, as per the approved shop drawings
and as directed by the Engineer-in-Charge.
GMRC Page 57 of
GMRC/CONS/DEPOT-2/2026 BOQ
Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, Sqm 2593.05 250
extruded aluminium section capping for fixing in the grooves of the curtain glazing
and vermin proof stainless steel wire mesh shall be paid for separately under
relevant items under this sub-head. However, for the purpose of payment, only
the actual area of structural glazing (including width of grooves ) on the external
face shall be measured in sqm. up to two decimal places. Note:-2. The following
performance test are to be conducted on structural glazing system if area of
structural glazing exceeds 2500 Sqm from the certified laboratories accreditated
by NABL(National Accreditation Board for Testing and Calibration Laboratories),
Department of Science & Technologies, India. Cost of testing is payable
separately. The NIT approving authority will decide the necessity of testing on the
basis of cost of the work, cost of the test and importance of the work.Performance
Testing of Structural glazing system. Tests to be conducted in the NBL Certified
laboratories, 1. Performance Laboratory Test for Air Leakage Test (-50pa to –
300pa) & (+50pa to +300pa) as per ASTM E-283-04 testing method for a range of
testing limit 1 to 200 mVhr”,2. Static Water Penetration Test. (50pa to 1500pa) as
per ASTME- 331-09 testing method for a range up to 2000 ml.”,3. Dynamic Water
Penetration (50pa to 1500pa) as per AAMA 501.01-05 testing method for a range
upto 2000 ml”,4. Structural Performance Deflection and deformation by static air
pressure test (1.5 times desing wind pressure without any failure) as per ASTME-
330-10 testing method for a range upto 50 mm”,5. Seismic Movement Test (upto
30 mm) as per AAMA 501.4-09 testing method for Qualitative test”Tests to be
conducted on site, 6. Onsite Test for Water Leakage for a pressure range 50 kpa to
240 kpa (35psi) upto 2000ml”
GMRC Page 58 of
GMRC/CONS/DEPOT-2/2026 BOQ
6.8 Providing and supplying aluminium extruded tubular and other aluminium sections Kg 308.74 2000
as per the architectural drawings and approved shop drawings , the aluminium
quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder
coating of 60-80 microns conforming to AAMA 2604 of required colour and shade
as approved by the Engineer-in-Charge. ( The item includes cost of material such as
cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame
work. Nothing extra shall be paid on this account). The weight of aluminium
extruded section shall be taken for purpose of payment.
GMRC Page 59 of
GMRC/CONS/DEPOT-2/2026 BOQ
6.9 Providing, assembling and supplying vision glass panels (IGUs) comprising of Sqm 2666.94 12
hermetically-sealed 6-12- 6 mm insulated glass (double glazed) vision panel units
of size and shape as required and specified, comprising of an outer heat
strengthened float glass 6mm thick, of approved colour and shade with reflective
soft coating on surface # 2 of approved colour and shade, an inner Heat
strengthned clear float glass 6mm thick, spacer tube 12mm wide, dessicants,
including primary seal and secondary seal (structural silicone sealant) etc. all
complete for the required performances, as per the Architectural drawings, as per
the approved shop drawings, as specified and as directed by the Engineer-in-
Charge. The IGUs shall be assembled in the factory/ workshop of the glass
processor. (Payment for fixing of IGU Panels in the curtain glazing is included in
cost of item No.25.2).
For payment, only the actual area of glass on face # 1 of the glass panels (excluding
the areas of the grooves and weather silicone sealant) provided and fixed in
position, shall be measured in sqm.
(i) Coloured tinted float glass 6mm thick substrate with reflective soft coating on
face # 2, + 12mm Airgap + 6mm Heat Strengthened clear Glass of approved make
having properties as visible Light transmittance (VLT) of 25 to 35 %, Light
reflection internal 10 to 15%, light reflection external 10 to 20 %, shading
coefficient (0.25- 0.28) and U value of 3.0 to 3.3 W/m2 degree K etc. The
properties of performance glass shall be decided by technical sanctioning authority
as per the site requirement.
6.1 Providing and applying plaster of paris putty of 2 mm thickness over plastered Sqm 161.68 47286
surface to prepare the surface even and smooth complete.
TOTAL OF SUB SECTION-6 : FINISHING WORKS
7 SUB SECTION-7 : ROOFING WORKS
GMRC Page 60 of
GMRC/CONS/DEPOT-2/2026 BOQ
7.1 Making khurras 45x45 cm with average minimum thickness of 5 cm cement Each 200.02 69
concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm
nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm
cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding
the edges and making and finishing the outlet complete.
7.2 Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in
true horizontal level, suspended on interlocking metal grid of hot dipped
galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive)
consisting of main "T" runner with suitably spaced joints to get required length and
of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm
center to center and cross "T" of size 24x25 mm made of 0.30 mm thick
(minimum) sheet, 1200 mm long spaced between main "T" at 600 mm center to
center to form a grid of 1200x600 mm and secondary cross "T" of length 600 mm
and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at
middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle of
size 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid
including, required cutting/making, opening for services like diffusers, grills, light
fittings, fixtures, smoke detectors etc. Main "T" runners to be suspended from
ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with
mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanized
butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center
along main T, bottom exposed width of 24 mm of all T-sections shall be pre-
painted with polyester paint, all complete for all heights as per specifications,
drawings and as directed by Engineer-in-charge.
GMRC Page 61 of
GMRC/CONS/DEPOT-2/2026 BOQ
7.2.1 8 mm thick fully perforated calcium silicate board made with Calcareous & Sqm 1443.48 3741
Siliceous materials reinforced with cellulose fiber manufactured through
autoclaving process to give stable crystalline structure with minimum compressive
strength 225 kg/ sq. cm, bending strength 100 kg/sq. cm , of size 595x595 mm,
having perforation of dia. 10 mm with minimum perforated area 18 % with non
woven tissue on the back side, having an NRC ( Noise Reduction Coefficient) of
0.85, with 50 mm thick rockwool of 48 kg /cum backing.
TOTAL OF SUB SECTION-7 : ROOFING WORKS
8 SUB SECTION-8 : MISCELLANEOUS WORKS
8.1 Providing and laying Damp-proof course 40 mm thick with cement concrete 1:2:4 Cum 285.03 786
(1 cement : 2 coarse sand : 4 graded stone aggregate 12.5 mm nominal size).
8.2 Steel work welded in built up sections/ framed work, including cutting, hoisting,
fixing in position and applying a priming coat of approved steel primer using
structural steel etc. as required.
8.2.1 In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works Cum 107.51 6518
8.3 Providing and fixing G.I. chain link fabric fencing of required width in mesh size Cum 745.91 435
25x25 mm made of G.I. wire of dia 3 mm including strengthening with 2 mm dia
wire or nuts, bolts and washers as required complete as per the direction of
Engineer-in-charge.
TOTAL OF SUB SECTION-8 : MISCELLANEOUS WORKS
GMRC Page 62 of
GMRC/CONS/DEPOT-2/2026 BOQ
9 SUB SECTION-9 : HORTICULTURE WORKS
9.1 Trenching in ordinary soil up to a depth of 60 cm including removal and stacking of Cum 56.67 6649.32
serviceable materials and then disposing of surplus soil, by spreading and neately
levelling within a lead of 50 m and making up the trenched area to proper levels by
filling with earth or earth mixed with sludge or manure before and after flooding
trench with water (Excluding cost of imported earth, sludge or manure).
9.2 Supplying and stacking of good earth at site including royalty and carriage up to 1 Cum 385.04 5588.7
km (earth measured in stacks will be reduced by 20% for payment).
9.3 Supplying and stacking of well decayed cowdung manure at site including royalty Cum 189.19 5588.7
and carriage upto 1 km (Cow dung manure measured in stacks will be reduced by
8% for payment).
9.4 Rough dressing the trenched ground including breaking clods. Sqm 0.83 6674.37
9.5 Mixing earth and sludge or manure in proportion specified or directed by the Cum 26.67 3676.58
office- in-charge
9.6 Spreading of sludge, dump manure or/and good earth in required thickness as per Cum 37.5 919.1
direction of Officer - in- charge (cost of sludge, dump manure or/and good earth to
be paid separately) and neatly levelling it.
9.7 Grassing with selection No. 1 grass including watering and maintenance of the Sqm 12.5 13875.76
lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit
for mowing including supplying good earth, if needed (the grass and good earth
shall be paid for separately)., In rows 5 cm apart in both directions.
9.8 Grassing with selection No. 1 grass including watering and maintenance of the Sqm 10 11207.46
lawn for 30 days or more till the grass forms a thick lawn, free from weeds and fit
for mowing including supplying good earth, if needed (the grass and good earth
shall be paid for separately)., with grass turf.
GMRC Page 63 of
GMRC/CONS/DEPOT-2/2026 BOQ
9.9 Renovating lawns including weeding, cheeling the grass, forking the ground, top Sqm 25 11167.06
dressing with sludge or manure, mixing the same with forked soil, watering and
maintaning the lawn for 30 days or more till the grass forms a thick lawn free from
weeds and fit for mowing and disposal of rubbish as directed, including supplying
good earth if needed but excluding the cost of sludge or manure (the good earth
shall be paid separately)
TOTAL OF SUB SECTION-9 : HORTICULTURE WORKS
10 SUB SECTION-10 : Any Other Works Under DSR
Total for Schedule C1:(NDSR Item)
GMRC Page 64 of
GMRC/CONS/DEPOT-2/2026 BOQ
DESCRIPTION ITEM UNIT RATE (Rs) Quantity Amount (Rs)
Schedule C2: HORTICULTURE WORKS (NDSR Item)
SUB SECTION-1 : METAL WORKS
Design, supplying and installing fixed type Z-Shaped louvered panels using louver blades Sqm 10054.78 100
of Z-Shaped minimum 60 microns super durable pure polyester powder coated, 2mm
thick aluminium slats in approved shape, colour and with ample rigidity within extruded
shape and with concealed stiffener, supports in approved spacing with an assumed
efficiency of 50%, including powder coated GI bird / vermin proofing wire netting
internally, all epoxy coated MS brackets, minimum 60 microns super durable pure
polyester powder coated aluminium extruded concealed frames and sub-frames,
approved fixing arrangement to main structure, etc. complete as per approved shop
drawings and specifications.
Note : (a) The spacing of the louver slats shall be as shown in the detailed drgs.
(b) The louvered panel shall be measured outside to outside of the aluminium frame or
inside to inside of the concrete / masonry opening to the nearest cm. for payment as the
case may be. The shade of the coating system shall be approved by the Engineer.
GMRC Page 65 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and fixing aluminium work for windows, ventilators with extruded built up Kg 530.16 1774.74
standard tubular sections/ appropriate Z sections and other sections of approved make
conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size,
including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with
required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust
free, straight, mitred and jointed mechanically wherever required including cleat angle,
Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all
complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing,
paneling and dash fasteners to be paid for separately) : Polyester powder coated
aluminium (minimum thickness of polyester powder coating 50 micron)
For louvers including fixing as per Architectural drawing.
Providing 250 x 150 mm panels with 6 mm thick 2 hour fire rated heat resistant glass of Each 352.86 87.4
boro sylicate float glass (Pi ran or approved equivalent) with 5mm ceramic fibre tapes.
SITC of electric motor single phase.230 V 50Hz. 600 kg set load lifting force for operating Nos 68555.3 2
rolling shutter
SITC of electric motor single phase.230 V 50Hz. 1000 kg set load lifting force for operating Nos 82266.36 12
rolling shutter
TOTAL OF SUB SECTION-1 : METAL WORKS
SUB-SECTION -2: FLOORING WORKS
Providing and laying in position matt finished vitrified floor tiles of size approved size, , Sqm 1203.83 770
approved make, colour, shade laid over cement mortar of mix 1:4 and thickness up to
20mm laid to the pattern as per approved drawing including cost of material, labour,
lead, lift, etc., complete as per specification and as directed by the Engineer-In-Charge.
GMRC Page 66 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and fixing vitrified wall tiles (with water absorption less than 0.08% and
conforming to IS : 15622) of 600 mm x 600 mm size of approved make, size, shade, quality
and thickness as per the manufacturer for dado/ cladding in required position including
cutting to required shape, fixing the tile including 12mm thick backing coat of cement
mortar 1:3 or set in special tile adhesive / neat cement paste as per manufacturer's guide
lines, finished to proper levels, slopes including , pointed flush in approved grouts
pigmented to match the shade of the tile, curing, cleaning, scaffolding / staging etc.
complete all as directed by Engineer.
Using 10mm thick matt finished vitrified tiles Sqm 1433.26 6182.48
Providing and laying machine cut mirror pre-polishedhoned granite stone slabs as per
architectural profile, in pieces upto 1.5 m length each, with machine cut edges for treads
of steps with full rounded nosing, engraving three nos., longitudinal grooves 25 mm apart
(size 6 mm wide, 3 mm deep ) for treads including the under layer of 20mm thick cement
mortar of 1: 4 (1 cement : 4 coarse sand) mix, fixed in white cement float / paste
pigmented to match the shade of the stone slab, filling joints with neat white cement
slurry leveling and matching coloured pigments & white cement, compaction, curing,
rubbing & polishing / flaming, washing, cleaning, making allowance for cutting & finishing
for railing fixings as per design etc. complete all as directed by the Engineer. The granite
stone shall confirm ASTM C-615, close grain, free from fissures, cracks, discoloration or
other defects. Horizontal surfaces to maintain a coefficient of friction 0.80 minimum shall
confirm to ASTM C-1028.
25mm thick machine cut mirror pre-polished honed dark coloured granite stone. Sqm 3822.64 246.05
GMRC Page 67 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and fixing polished machine cut honed granite stone slabs in risers of steps, in
pieces upto 1.5 m length each, including 15mm thick cement mortar in 1 : 3 (1 cement :
coarse sand) backing coat, fixing in white cement slurry paste with matching pigment for
joints, joints to match with the line of floor joints, edge polishing, mirror polishing,
cleaning, curing etc., complete as per drawing and as directed by the Engineer.
20mm thick machine cut mirror pre-polished honed dark coloured granite stone.20mm Sqm 2729.41 71
thick machine cut mirror pre-polished honed dark coloured granite stone.
Providing and laying in position matt finished vitrified skirting of size 600mm x 300mm, , Sqm 1267.82 28
approved make, colour, shade laid over cement mortar of mix 1:3 and thickness up to
20mm laid to the pattern as per approved drawing including cost of material, labour,
lead, lift, etc., complete as per specification and as directed by the Engineer-In-Charge.
Providing and Laying Foam Concrete for raised flooring as/of density 1200kg/cum Cum 3991.75 284
Providing and Laying 25mm thick prepolished granite slab of any colour size up to and Sqm 3024.66 857
including 1200x600mm on floor using 5mm thick approved thick bed adhisive as per
specification over prepared base on 20mm (average) thick base of cement mortar in 1:4 (
1 cement : 2 sand and 10mm single sized aggregate) usign 43 grade cement water
reducing admixture as per ISO 9103:1999 and jointing with white cement with matching
colour pigment all complete in levelling course laid to proper slope over screed base
including base preparation including movement joint in screed as per specification with
10mm thick compressible filler to edge of screed with two parts polysulphide sealent to
top edge as per approved drawing and directions of engineer-in-charge. screed shall be
measured and paid extra as per DSR item no. 4.1.8
GMRC Page 68 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and Laying 30mm thick mirror polished sadarhalli grey/cheema pink/jhalore Sqm 4596.86 165
belge or equivelent granite stone of upto and including size of 1200mmx600mm of
approved colour pattern with 4mm groove all around at all levels for wall
lining/columns/skirting (veener work) by mechanical arrangement with SS cramps/
brackets anchor bolts 6mm vertical SS pins of approved make and inserts as per drawings
and specifications. Cost of making necessary grooves all around stone places, chamfering
of corner edge and polishing are included.as approved by engineer incharge.
Extra for Red/raw, silk/tan, brown/jet black granite Sqm 658.13 165
Providing and laying light shade vitrified tiles 8mm to 10mm thick in skirting, risers of Sqm 1188.29 335
steps and dado on 10mm thick cement plaster 1:3 (1 cement : 3 Coarse sand) and jointed
with white cement slurry.
TOTAL OF SUB-SECTION -2: FLOORING WORKS
SUB-SECTION -3 : ROOFING WORKS
Providing and laying broken white glazed China mosaic flooring for plain and curved Sqm 433.27 12192
surfaces on terraces, floors, balconies, roofs, walls etc comprising of 12mm to 20mm size
broken pieces of ceramic/ glazed tiles, laid over cement mortar 1: 3 bedding on plain or
sloped surfaces. The flooring shall be tamped to bring the cement mortar cream upto the
surface, including rounding of junctions and extending them upto 30 cm along the
parapet.The rate shall include bands, if different color is used, any pattern or design as
per drawing and direction,finishing with white cement, curing, cleaning with water and
oxalic acid, etc complete at all levels, as directed and to satisfaction to the engineer in
charge. Rate shall include all tools, tackles, machines,
necessary scaffolding, adding of waterproofing material as recommended in the
bedding mortar by the Engineer in charge.
TOTAL OF SUB-SECTION -3 : ROOFING WORKS
SUB SECTION-4 : MISCELLANEOUS WORKS
GMRC Page 69 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and fixing toilet mirror in 6 mm thick clear float glass with bevelled and polished Sqm 2419.54 42
at edge and copper coating on rear side. Fixed on wall with 6mm thick plywood and kraft
paper backing fixed to wooden cleats with 8mm dia 38mm long stainless steel stud
Providing and fixing in position frameless glass partition walls made out of 12mm thick Sqm 12097.72 155
toughened clear float glass (or equivalent) held in position by wall connecting profile
(with or without open able glass door made out
(i) Two Set of 350mm long pull handles of approved make
(ii) Two number corner locks US10 of approved make
(iii) Floor spring BTS-80 of approved make.
(iv) Lock keeper Plate stainless steel strip at the bottom of doors for doors exceeding
1100mm With openable door
GMRC Page 70 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing & fixing Toilet Cubicle (of following standard dimension which includes 600mm Nos 28988.84 21
door size width) made of heat, bacteria, water, chemical, scratch, impact and anti
bacterial resistant 12mm thick solid compact laminate panels tested in approved
laboratory. Finish of the compact laminate should be Suede, Raw silk model includes
doors, pilasters & intermediate panels finished with approved texture/shade as per the
detail drawings & as per IS 2046 (Indian Standard) and as per fire retardant BS-476/97
standard. This also includes providing and fixing in position necessary hardware made out
of Stainless steel (Grade 304) as per manufacturer’s specifications & Architects
instructions like (1) Door Knob, (2) Gravity Hinges, (3) Thumb turn lockset with Occupancy
indicators, (4) Coat hooks, (5) Door stopper, (6) U- Channels, (7) Adjustable foot/pedestal,
(8) Top rail (9) Rubber noise deafening tape, (10) Screws & wall Plugs. All screws will of
304 Grade in stainless steel with satin finish. All pilasters are supported by stainless steel
Bottom Cladding.
The base of the stainless steel bottom cladding will be anchored to the floor with a
clearance height upto 150mm. The top fitting should consist of SS round top rail which
will get fixed with pilasters SS wall fixing is used only on the wall which will hold the SS
Note: All works as per approved manufacturer's specifications.
Toilet Cubicle with standard dimension of 2000-2100mm Height x 1000mm Width x
1550mm Depth, which includes 600mm wide door.
Providing and fixing polished granite coping, bull nosed over 20 mm thick cement mortar Sqm 3628.86 51
1:4(1 cement : 4 coarse sand) with joint treated with white cement mixed with matching
pigment including rubbinng, curing, moulding and poiiishing to edge to give high rise gloss
finish etc. complete.
GMRC Page 71 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing, supplying, erecting and fixing in position 3mm thk Polycarbonate sheets of Sqm 4003.63 83
approved texture and colour for side lighting. Sheets to be profiled to match metal sheets
described in item at sl. No. 7.1 of B2 sectionand should include cost of laying sheets in
curvature where required. Cost to include jointing, sealing with Butyl adhesives and takes
as per manufacturers specifications and cover all costs of labour tools, parts, temporary
works etc all complete.
GI Louver of size 300mmx400mm Each 783.36 84
Supply and fixing of sliding doors with all fixtures Sqm 9414.93 17
Supply and fixing of Foldable gate with all fixtures Sqm 10580.37 92
TRAP DOOR - Hingeable & sliding trap door system manufactured according to EN13964 Sqm 6978.93 130
TAIM Quality standard comprising 2 pannels of size mentioned in drawings one unit made
up of 0.6 GMS in RAL 9016 (Matt White colour) or as specified by Engineer, polyester
powder coated finish and approx 95% humidity resistance, fire performance Class A2-S1,
d0. Substructure consisting of roburst hinging
technology with visible U 1091 G shaped or equivalent profiles which are mounted along
the width of the panels. The U 1091G profiles or equivalent are fixed using L shaped
primary carriers U 1040 or equivalent of 1.0mm thick GMS, which runs perpendicular to
the U 1091 G profiles. This is suspended rigidly from the bare ceiling with M6 or
equivalent threaded rods and fasteners. All components are made of galvanized steel.The
rectangular panels can be swing down using spring loaded pins and hung from bolted
sleeves provided on the sides. Once all the panels are swung down, they can be pushed to
either side of the opening and stacked together in order to carry out any kind of
Making of cutout (core cutting) in pre-costructed RCC / CC work of all grades for services
RCC wall core cutting 100mm dia RM 2445.14 10
GMRC Page 72 of
GMRC/CONS/DEPOT-2/2026 BOQ
RCC Wall Core Cutting 150mm dia RM 3298.88 60
RCC wall Core Cutting 200mm dia RM 4095.04 30
Providing and fixing wire mesh (26 gauge) at the junctions of RCC & brick work fixed with Sqm 79.52 224
wire nail in cement mortar 1:4 (1 cement : 4 fine sand) etc. Complete.
Providing and laying at or near ground level factory made kerb stone of standard size with Cum 7873.39 170
M25 grade 20 mm or down size aggregate of cement concrete(size as per gfc drawing) in
position to the required line, level and curvature, jointed with cement mortar 1:3 (1
cement: 3 coarse sand), including making joints with or without grooves (thickness of
joints except at sharp curve shall not to more than 5mm), including making drainage
opening wherever required complete etc. as per direction of Engineer-in-charge (length
of finished kerb edging shall be measured for payment). (Precast C.C. kerb stone shall be
approved by Engineer-in-charge).
Extra for providing perforated rolling shutters of 1.2mm thick steel plate as per design Sqm 585.01 79.87
approved by Engineer-in- charge, (area of grill to be measured).
Providing and fixing factory made uPVC door frame made of uPVC extruded sections Meter 256.58 200
having an overall dimension as below (tolerance ±1mm), with wall thickness 2.0 mm (±
0.2 mm), corners of the door frame to be Jointed with galvanized brackets and stainless
steel screws, joints mitred and Plastic welded. The hinge side vertical of the frames
reinforced by galvanized M.S. tube of size 19 X 19 mm and 1mm (± 0.1 mm) wall thickness
and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer’s
specification and direction of Engineer in-charge extruded section profile size 42 X 50 mm
GMRC Page 73 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and fixing factory made 30 mm thick door shutter made of solid PVC foam
profile. The styles & rails shall be of size 75 mm x 30 mm having wall thickness 5 mm. The
styles, top & bottom rails shall have one side wall thickness of 15 mm integrally extruded
on the hinge side of the profile for better screw holding power. The styles and rails shall
be reinforced with M.S. tubes of size 33 mm x 17 mmx 1 mm, painted with primer , all
four corners of reinforcement to be welded or sealed. Solid PVC extruded bidding (push
fit type) will be set inside the styles and the rails with a cavity, to receive single piece
extruded 5mm PVC sheet as panel. The styles and rails will be mitred cut and joint with
the help of PVC solvent cement & self driven self tapping screws.
Single piece extruded solid PVC lock rail of size 100 mm x 30 mm with wall thickness
mm & 15 mm integrally extruded in the middle of the lock rail & fixed with styles with the
help of PVC solvent cement & self driven self tapping screws of size 100mm x 8 mm
complete as per manufacturer's specifications and direction of Engineer-in-charge.
Decorative finish (both side wood grained finish) Sqm 2919.91 100
Providing and fixing pressed steel door frames conforming to IS: 4351, manufactured
from commercial mild steel sheet of 1.60 mm thickness, including hinges, jamb, lock
jamb, bead and if required angle threshold of mild steel angle of section 50x25 mm, or
base ties of 1.60 mm, pressed mild steel welded or rigidly fixed together by mechanical
means, including M.S. pressed butt hinges 2.5 mm thick with mortar guards, lock strike-
plate and shock absorbers as specified and applying a coat of approved steel primer after
pre-treatment of the surface as directed by Engineer-in-charge:
Fixing with adjustable lugs with split end tail to each jamb Meter 406.3 100
Supplying & applying Fluoroshine/ epoxy for maintaining shine of VDC floors using Sqm 411.33 5986.28
mechanical polishing as approved by Engineer in charge
GMRC Page 74 of
GMRC/CONS/DEPOT-2/2026 BOQ
Designing, fabricating, testing, installing and fixing in position Curtain Wall with Sqm 4089.73 28
Aluminium Composite Panel Cladding, with open grooves for linear as well as curvilinear
portions of the building , for all heights and all levels etc. including:
Providing and Fixing Anutone Subtex Texture Steppe edge 15mm for Ceiling of size Sqm 2285.18 2206
595x595x15mm is to be installed on framework of Anutone Soundskelet, which will
comprise of NRC 0.94 base panel with humidity resistance of 90% RH as per ISO-
4611,ASTM C-165,ASTM C303, ASTM C-1104 and light reflectance upto 85% with Leed
points Green Performance certified, and Thermal conductivity K=0.82 W/MK with sag
resistance with normal edge profile. Anutone Subtex Texture 15 mm for Ceiling tile meet
the stringent fire test required having Class 'A' rating for Flame Ignitability test as per
ASTM-E-84, with complete framework of Anutone SoundSkelet as per manufacturers
Installation details and the Architectrual drawing.
Providing and Fixing Anutone Ekcelsior SoundSoak (Cord) Panel of size 1200x600x25 mm Sqm 3839.1 323.26
ND 4 with Anutone SoundStrut Sound Profile F-Spline, which will comprise to NRC
Anutone Ekcelsior FABRICO SoundSoak Panel is to be installed on Anutone SoundStrut
framework and meet the stringent fire test required having Class 'P' rating for Ignitability
test as per BS 476 part 5 and Class '1' rating as per BS 476 part 6 Fire Propagation index
and for Flaming ISO 1182 and Smoke density as per ASTM E 662 basides base panel
conform to EN 13168 2000 with complete Anutone SoundStrut frame work as per
manufacturers Installation details and the Architectrual drawing.
Providing and fixing trapdoor for HVAC indoor unit, of hard wood frame and 6mm Sqm 8043.82 115
plywood shutter (shutter is made by 6mm plywood both side sadwich with wooden
Grouting with Hilti HY-200 R for :
12 dia reinforcement No 228.52 192
16 dia reinforcement No 319.92 44
GMRC Page 75 of
GMRC/CONS/DEPOT-2/2026 BOQ
20 dia reinforcement No 411.33 20
Providing and injecting chemical emulsion for PRE- sqm CONSTRUCTIONAL anti Sqm 190.13 11053.24
termite treatment and creating a chemical barrier under and around the column pits, wall
trenches, basement excavation, top surface of plinth filing junction of wall and floor,
along with the external perimetre of building, expansion joints surrounding of pipes and
conduit etc, complete (plinth area of the building at ground floor only shall be
measured) using Chlorpyriphos/ Lindane emulsifiable concentrate of 20%.
TOTAL OF SUB SECTION-4 : MISCELLANEOUS WORKS
SUB-SECTION -5 : HORTICULTURE WORKS
Preparation of subgrade by excavating earth to an average of 225 mm depth, dressing to Sqm 24.68 11082
camber and consolidating with road roller including making good the undulations etc. and
disposal of surplus earth for all lead.
Sprinkiler and Accessories
Providing & fixing of Pop up sprinkler full/part circle having radius of throw 6.7 m-15.2 m Nos 2165.43 106
& floww of 0.09 -0.16 Ltr /sec at an operative pressure of 2.5- 4.5 kg/cm sq .The sprinkler
is gear driven ratary type with RC technology having 3/4"bottom inlet, with slip clutch
mechanism and heavy duty retract spring memory arc,non strippable and brass
reinforced nozzle turret.The sprinkler shall have multifunction, pressure activated wiper
seal for low pressure operation the sprinkler shall have internal seal A Metric device
which prevents low head drainage up to 3.1 m) & hence pudding & erosion.The body of
sprinkler is non corrodable heavy duty ,ABS plastic
Providing & fixing of POP up spray head having variable adjustable arc and two pieces Nos 520.11 890
stem ratchet (0 to 360 degres ) nozzle capable of covering 0.9-5.5 mat 1.0-2.1 bars with a
discharge rate of 0.23- 0.33 lps .The spray head body ,stem,nozzle,ratchet and screen
shall be constructed of heavy duty , ultra voilet resistant plastic and stainless steel with
multifunctional wiper seal with small exposed cover US400
GMRC Page 76 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing & fixing of 1/2"pop up connecting swing joint assembly. The tubing shall be Nos 545.7 890
made of polythene having wall thickness of 2.3 mm a working pressure of 5.5 kg/sq cm at
43* c and a surge pressure of 16.6 kg/sq cm .The fittings shall be made of UV resistant
thermo plastic SA series.
Providing & fixing of 3/4"pop up connecting swing joint Assembly .The tubling shall be Nos 598.72 106
made of polythylene having wall thickness of 2.3 mm a working pressure of 5.5 kg/ sq cm
at 43* C and a surge pressure of 16.6 kg/ cm Sq .The fitting shall be made of UV resistant
thermo plastic SA series.
Valve & Accessories
Providing valve 63mm providing & fixing Brass Ball valve security pivot to maintain level in Nos 2472.56 53
space double water tight joint direct injection stem non mechanical with a base which
permits maximum penetration in to the valve etc complete as per specification and
drawing (Ball vaive 63mm dia)
Providing & fixing of a double acting Air release valve 3/4" made of high strength Nos 730.34 19
aluminum/plastic with fiber glass reinforced. The Air release valve shall be capable of
both releasing and admitting air from and into the line. The working pressure shall be
12" Rectangle valve Box with green lid and corrugated structure with unique shovel Nos 1848.25 53
access slot and bolt hole knockout.
Quick coupling valve made up of solid brass with locking cover corrosion resistant and Nos 1269.64 84
stainless steel spring 3RC.
Vertical Jet Foundation
Vertical Jet Nozzle (40) M.O.C Brass / Gunmetal Nos 1005.48 1
Vertical Jet Nozzle (25) M.O.C Brass / Gunmetal Nos 1371.11 8
Submersible Pump 5HP Nos 22851.77 1
Submersible Niche Liqht (NL1250HN) 12v 50w light in Noryl body to highlight the fountain Nos 2376.58 19
Stepdown Transformer of required capacity for the Lights (12V1000W) Nos 28336.19 1
Stepdown Transformer of required capacity for the Lights (12V500W) Nos 31992.47 1
GMRC Page 77 of
GMRC/CONS/DEPOT-2/2026 BOQ
Weather Proof Junction Box in FRP Nos 19195.48 4
FRP sump cover for pump. Nos 10054.78 1
Imported Pressure Sand Filter (450 dia) with multiport valve & pump Nos 31992.47 1
500D Floor Inlet (ABS) Nos 1919.55 3
Vacuum Point (ABS) Nos 2285.18 1
Chlorine dispensinq unit Nos 13711.06 1
Water level Controller cum drv run protection - Electrical type with Solonoid control. Nos 3199.25 1
Control Panel made of 16 gauge CRC sheet powder coated with Starter, Single phase Nos 19195.48 1
prevention, MCB, volt-meter, Amp meter, TP MCB's, Protection circuits etc and space for
step-down Transformers for the lights.
Complete plumbinq required for the fountain in uPVC pipe (10 Kg Pressure) including LS 68555.3 1
necessary control valves etc (excluding inlet and drain)
Complete electrical work required for the fountain including pump, light, panel, LS 68555.3 1
transformer connections (Individual wires for each light up to junction box within 10M.
From water body)
Installinq. testinq. commissioninq, shop drawings LS 68555.3 1
TOTAL OF SUB-SECTION -5 : HORTICULTURE WORKS
SUB SECTION-6 : SIGNAGE WORKS
GMRC Page 78 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and fixing Wall mounted / Door Signs complete as per requirement of the Nos 1096.88 250
Engineer Incharge. Before execution shop drawings shall be approved by Engineer
Modular Signages using Aluminium extrusions (Alloy 6060) with Anodizing (thickness 15-20
microns) ISO:9001-2008 product with Premium grade Anodizing as per
Qualanod and Qualicoat International standards. With Lifetime warranty under normal
working conditions. Signage depth 25mm. Protile outer thickness 2.5mm and inner
thickness 1.5mm with profile weight of 0.492 Kg per meter. Corner used to creat frame.
4mm FR Grade ACP AL45 used on both sides with 3M IJ 180C vinyl with 8520 over
laminate/IJ480C non pvc vinyl with 8550 non pvc over laminate/Diamond Grade Type 11 -
Retrorefective fixed inside with the help of double sided tape. Signage will be fixed by
passing screws from star corner which will be fixed by drilling into the wall.
Sizes shall be as per design or directed by engineer. Average height of signage 400 x
GMRC Page 79 of
GMRC/CONS/DEPOT-2/2026 BOQ
Providing and fixing sheet channel letter signs Logo, Station name, Depot building/shade
name, backlit with LEDS and face of the signs treated with colour acrylic/epoxy rasin faced
as per design complete with fixing in place with heavy duty anchor system. Supply of
illuminated channel letters, the sign shall comprises of 3D built up GMRCL Logo of
appropriate size (height nearly 1000mm) and channel letters in required font of Gujarati or
Hindi and English in 600mm font height depicting station name fixed on either side of the
logo supported on rigid suporting system in steel/wall fixing. Channel letters in required
font of Gujarati or Hindi and English in 300mm to 600mm font height depicting Depot
building/shade name supported on rigid supporting system in steel/wall fixing.
*CNC cutting Aluminium letter
*Material thickness 3mm.
*Anodized coating as per specification.
Main Station and Depot Identity name shall be illuminated, Exterior
LED Channel Letters
*Reverse letter made with 3mm Aluminium ((Approximately height
*100mm sides of Signages by bedable alum alloy.
*Both back & side assemble with by Argon welding
*Top Signage sheet fabricated of 5mm thick. Opal Cast A grade PMA
sheet 3/4" ring made of 5mm plexi
*IP=65 High power chips LED modules (CE certified) 12V DC 1-1.4
watt beam angle 140/160.
*Input Voltage 220V AC-Input frequency 47 Hz Max. Output power
The Sign and the logo shall have hallow lit effect by LED's.
GMRC Page 80 of
GMRC/CONS/DEPOT-2/2026 BOQ
Sizes shall be as per design or directed by engineer. Average height of channel letter Nos 4113.32 100
450mm (Non-Lit).
Sizes shall be as per design or directed by engineer. Average height of channel letter Nos 5484.42 125
600mm (Lit Signage)
Providing and fixing Suspended / Emergency Exit / Wayfinding / Evacuation / Illuminated Nos 18281.41 100
Signages complete as per requirement of the Engineer Incharge. Before execution shop
drawings shall be approved by Engineer Incharge. (1000 x 1500mm)
Modular Signages using Aluminium extrusion (Alloy 6060) with Anodizing (Thickness 15-20 Nos 11425.88 20
microns). ISo:9001-2008 product with Premium grade Anodizing as per Qualanod and
Qualicoat International standrards. With Lifetime warranty under normal working
conditions. 1.5mm with profile weight of 0.492 kg per meter. Corners used to creat frame.
Router cutting done on 4mm FR grade ACP AL 45 and block out lighting done by using leds
and acrylic. ACP and Acrylic to be covered with 3M IJ 180C vinyl with 8520 over
laminate/IJ480c non PVC vinyl with 8550 non pvc over laminate. Lucoled Edge Lighting EL
30 modules being used to make the signage lit with 5 years warranty and Hi-sign/union
SMPS with 3 years warranty. SS 316 CHS (circular hollow section) of Dia 1.5" is used to
Suspend the box. The Height of the pipe can be as per different locations on Site Height can
be maximum upto 6 feets.
Sizes shall be as per design or directed by engineer. Average size of exit signage taken as
Providing and fixing Projected Signages complete as per requirement of the Engineer
Incharge. Before execution shop drawings shall be approved by Engineer Incharge.
GMRC Page 81 of
GMRC/CONS/DEPOT-2/2026 BOQ
Modular Signages using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness 15- Nos 11425.88 5
20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod
and Qualicoat International standards. With Lifetime warranty under normal working
Signages depth 50mm. Profile outer thickness 2.5mm and inner thickness 1.5mm with
profile weight of 0.839 kg per meter. Corners used to create frame.
4mm FR grade ACP AL45 used on both sided with 3M IJ 180C Vinyl with 8520 over
laminate/IJ480C non pvc vinyl with 8550 non pvc over laminate/Diamond Grade Type 11 -
Retrorefelctive.
For a IDDS Display box of approx. size 950 mm x 450 mm: A MS (mild steel) RHS 50 x 25 x
mm horizontal member welded on a 10mm thick mounting plate supported by triangular
gusset plate of 8mm thick. This Structural mounting is stable enough for our IDDS. A cover
plate of full or half size covers the mounting and gusset plate.
A MS Flat 40mm x 3 mm thick rolled in pillar Diameter and bent on edges holds the frame Nos 22851.77 2
using star corner. The Connector had the enough strength to hold even heavy glasses in
Totem Modular Totems using Aluminium extrusions (Alloy 6060) with Anodizing (Thickness
15-20 microns). ISO:9001-2008 product with Premium grade Anodizing as per Qualanod
and Qualicoat International standards. With Lifetime warranty under normal working
conditions. Sections can be used to create totems upto 6m with variable depth as per
requirement. Basic profile with thickness 2mm and 1.525 kg/meter. Round cover profile of
thickness 2mm and 1.136 kg/meter. Ease of graphics change and maintenance.
Preparation of Model for Surat Depot with a Scale of 1:400. complete in all respects as per No 1371105.96 1
specifications and drawings and as directed by Engineer Incharge.
TOTAL OF SUB SECTION-6 : SIGNAGE WORKS
Total for Schedule C2:HORTICULTURE WORKS (NDSR Item)
GMRC Page 82 of
GMRC/CONS/DEPOT-2/2026 BOQ
ITEM DESCRIPTION ITEM UNIT RATE Quantity Amount
P 01 SUB SCHEDULE-1 : SANITARY FIXTURES & FITTINGS
1.1 Providing and fixing white vitreous china extended wall mounting water closet of size Nos 12914.1 63
780x370x690 mm of approved shape including providing & fixing white vitreous china
cistern with dual flush fitting, of flushing capacity 3 litre/ 6 litre (adjustable to 4 litre/
litres), including seat cover, and cistern fittings, nuts, bolts and gasket etc complete.
1.2 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of Nos 3418.6 120
approved quality conforming to IS:8931 Geyser 3ltrs & Shower
1.2.1 Providing & fixing white vitreous china water less urinal of size 600 x 330 x 315 mm Nos 15725.37 44
having antibacterial /germs free ceramic surface, fixed with cartridge having debris
catcher and hygiene seal.
Granite Stone of approved shade
1.3 Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm
C.P. brass waste of standard pattern, including painting of fittings and brackets,
cutting and making good the walls wherever require:
1.3.1 White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass Nos 2878.25 24
1.4 Providing and fixing C.P. brass angle valve for basin mixer and geyser points of
approved quality conforming to IS:8931
1.4.1 15mm nominal bore Nos 496 217
1.5 Providing and fixing CP Brass 32mm size Bottle Trap of approved quality & make and Nos 823.65 87
as per the direction of Engineerin- charge.
GMRC Page 83 of
GMRC/CONS/DEPOT-2/2026 BOQ
1.6 Providing and fixing Stainless Steel A ISi 304 (18/8) kitchen sink as per IS: 13983 with
C.I. brackets and stainless steel plug 40 mm, including painting of fittings and brackets,
cutting and making good the walls wherever required :
1.6.1 510x1040 mm bowl depth 178 mm Nos 4831.47 50
1.7 Providing and fixing C.P. brass long body bib cock of approved quality conforming to IS
standards and weighing not less than 690 gms.
1.7.1 15 mm nominal bore Nos 515.01 40
1.8 Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931:
1.8.1 15 mm nominal bore Nos 391.01 145
1.9 Supply installation, testing and commissioning of recessed bi level drinking water Nos 142049.6 4
fountain, with double bubbler,round shape. Drinking water fountain with 12GPH
cooling capacity, stainless steel body ,approx size 1003mmX Depth 400 mmX hight
1035mm, flexible bubbler guard operated between 50 to 120 PSI, chilling unit suitable
for R134a refrigerant, adjustable thermo state, supply complete with all accessories.
The rate also including UV and Sediment Filter for LMC Water complete in all respect.
Nothing shall be paid extra.
2 Providing & fixing White vitreous china water closet squatting pan (Indian type) along Nos 3298.22 4
with "S" or "P" trap including dismantling of old WC seat and "S" or "P" trap at site
complete with all operations including all necessary materials, labour and disposal of
dismantled material i/c malba, all complete as per the direction of Engineer-in
charge.(Orissa pattern W.C Pan of size 580x440 mm)
TOTAL OF SUB SCHEDULE-1 : SANITARY FIXTURES & FITTINGS
P 02 SUB SCHEDULE-2 : INTERNAL WATER SUPPLY
GMRC Page 84 of
GMRC/CONS/DEPOT-2/2026 BOQ
2.1 Providing, laying, jointing and testing of following sizes of pipes conforming to IS-1239
part 1/1974 and part 11/1979 with all accessories like fittings with welded joint 'shall
be used like tees, elbows, reducers, flanges, rubber gaskets, GI nuts bolts, washer
including excavation in all kinds of soil and refilling including bed preparation the
trench all complete. The rate shall also include providing and applying one coat of
mm thick 'PYPKOTE' or COATEK anti rust pipe protection including approved primer as
per manufacturers specifications and lap of 25 mm to make an impermeable layer on
MS pipes in trenches or on structural/masonary members complete including surface
Internal Work - Exposed on wall
2.1.1 15mm nominal outer dia pipes RM 225.37 1200
2.1.2 20mm nominal outer dia pipes RM 286.01 950
2.1.3 25mm nominal outer dia pipes RM 343.94 400
2.1.4 32mm nominal outer dia pipes RM 448.03 400
2.1.5 40 mm nominal outer dia pipes RM 604.61 80
2.1.6 50 mm nominal outer dia pipes RM 842.66 220
2.1.7 62.50 mm nominal outer dia pipes RM 1447.27 550
2.2 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply, including all CPVC plain & brass threaded fittings,
i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes &
fittings with one step CPVC solvent cement and the cost of cutting chases and making
good the same including testing of joints complete as per direction of Engineer in
Concealed work, including cutting chases and making good the walls etc.
2.2.1 15mm nominal outer dia pipes RM 381.96 450
2.2.2 20mm nominal outer dia pipes RM 445.31 300
2.2.3 25mm nominal outer dia pipes RM 524.06 40
2.2.4 32mm nominal outer dia pipes RM 633.58 6
GMRC Page 85 of
GMRC/CONS/DEPOT-2/2026 BOQ
2.3 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in
the chilled water plumbing duly insulated to the same specifications as the connected
piping and adequately supported as per specifications.
2.3.1 BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16
pressure rating for chilled water/ hot eater circulation as specified
2.4 Providing and fixing ball valve (brass) of approved quality, High or low pressure, with
plastic floats complete :
2.5 Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed
TOTAL OF D: P 02 SUB SCHEDULE-2 : INTERNAL WATER SUPPLY
P 03 SUB SCHEDULE-3 : EXTERNAL WATER SUPPLY (NDSR Item)
3.1 Providing, laying, jointing and testing of following sizes of pipes conforming to IS-1239
part 1/1974 and part 11/1979 with all accessories like fittings with welded joint 'shall
be used like tees, elbows, reducers, flanges, rubber gaskets, GI nuts bolts, washer.
(Treated Water supply)
3.1.1 20mm nominal outer dia pipes RM 264.29 200
3.1.2 25mm nominal outer dia pipes RM 339.42 100
GMRC Page 86 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.1.3 32mm nominal outer dia pipes RM 395.53 40
3.1.4 40mm nominal outer dia pipes RM 450.74 12
3.1.5 50 mm nominal outer dia pipes RM 526.77 200
3.1.6 65 mm nominal outer dia pipes RM 667.07 240
3.1.7 80 mm nominal outer dia pipes RM 807.36 90
3.1.8 100 mm nominal outer dia pipes RM 1516.96 90
3.1.9 150 mm nominal outer dia pipes RM 2115.24 5600
3.2 Providing, laying, jointing and testing of following sizes of pipes conforming to IS-1239
part 1/1974 and part 11/1979 with all accessories like fittings with welded joint 'shall
be used like tees, elbows, reducers, flanges, rubber gaskets, GI nuts bolts, washer
including excavation in all kinds of soil and refilling including bed preparation the
trench all complete. The rate shall also include providing and applying one coat of
mm thick 'PYPKOTE' or COATEK anti rust pipe protection including approved primer as
per manufacturers specifications and lap of 25 mm to make an impermeable layer on
MS pipes in trenches or on structural/masonary members complete including surface
3.2.1 20mm nominal outer dia pipes RM 32.58 184
3.2.2 25mm nominal outer dia pipes RM 37.11 100
3.2.3 32mm nominal outer dia pipes RM 47.07 40
3.2.4 40mm nominal outer dia pipes RM 56.12 5
3.1.5 50 mm nominal outer dia pipes RM 74.22 180
3.1.6 65 mm nominal outer dia pipes RM 85.08 229
3.1.7 80 mm nominal outer dia pipes RM 104.09 75
3.1.8 100 mm nominal outer dia pipes RM 133.96 75
3.1.9 150 mm nominal outer dia pipes RM 197.31 22
GMRC Page 87 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.3 Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal
stability for hot & cold water supply including all CPVC plain & brass threaded fittings
This includes jointing of pipes & fittings with one step CPVC solvent cement, trenching,
refilling & testing of joints complete as per direction of Engineer in Charge.(Garden
3.3.1 25mm nominal outer dia pipes RM 304.12 810
3.3.2 32mm nominal outer dia pipes RM 385.58 218
3.3.3 40mm nominal outer dia pipes RM 500.53 195
3.3.4 50mm nominal outer dia pipes RM 737.66 127
3.3.5 62.50 mm nominal inner dia Pipes RM 1447.27 10
3.3.6 75 mm nominal inner dia Pipes RM 1832.85 35
3.3.7 100 mm nominal inner dia Pipes RM 2591.33 3325
3.4 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in
the chilled water plumbing duly insulated to the same specifications as the connected
piping and adequately supported as per specifications.
3.4.1 BUTTERFLY VALVE (MANUAL) with C I body SS Disc, Nitrile Rubber Seal & O-Ring PN 16
pressure rating for chilled water/ hot eater circulation as specified
3.5 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in
the chilled water plumbing duly insulated to the same specifications as the connected
piping and adequately supported as per specifications.
GMRC Page 88 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.5.1 NON - RETURN VALVE with duel plate of C I body SS plates vulcanized NBR seal flanged
end & PN 16 pressure rating for chilled / hot water circulation including insulation as
3.6 Supplying, fixing, testing and commissioning of following valves, strainers, gauges in
the chilled water plumbing duly insulated to the same specifications as the connected
piping and adequately supported as per specifications.
3.6.1 Y - STRAINER of Ductile CI Body flanged ends with stainless steel strainer for chilled /
hot water circulation including insulation as specified.
3.7 Providing and fixing enclosed type water meter (bulk type) with pressure reducing
valve conforming to IS : 2373 and tested by Municipal Board complete with bolts,
nuts, rubber insertions etc. (The tail pieces if required will be paid separately) :
3.8 Constructing masonry Chamber 60x45x50 cm inside, in brick work in cement mortar Nos 7737.78 2
1:4 (1 cement : 4 coarse sand) for water meter complete with C.I. double flap surface
box 400x200x200 mm (inside) with locking arrangement and RCC top slab 1:2:4 mix (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) , i/c necessary
excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand:10 graded stone
aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1
cement : 3 coarse sand) 12 mm thick, finished with afloating coat of neat cement
complete as per standard design : (External Valve Chamber)
GMRC Page 89 of
GMRC/CONS/DEPOT-2/2026 BOQ
3.9 Polyethylene water storage tank with cover and suitable locking arrangement
3.9.1 5 KL tank capacity Nos 25637.22 8
3.9.2 2.5 KL tank capacity Nos 12819.06 2
3.9.3 2 KL tank capacity Nos 10254.89 2
3.9.4 1 KL tank capacity Nos 5127.44 1
3.9.5 3 KL tank capacity Nos 15382.33 1
3.9.6 1.5 KL tank capacity Nos 7691.62 1
3.9.7 0.5 KL tank capacity Nos 2564.17 4
3.1 Providing and fixing mild steel pressure reducing valves with all accessories pressure
gauges bolts,nuts and flanges etc,.
100 MM to 15 mm dia Nos 8717.11 2
TOTAL OF D: P 03 SUB SCHEDULE 3 :EXTERNAL WATER SUPPLY (NDSR Item)
P 04 SUB SCHEDULE 4: INTERNAL DRAINAGE (SOIL, WASTE, VENT AND RAIN WATER
4.1 Providing and fixing uPVC SWR TYPE B pipes for soil, waste and vent As per IS 3592 on
the wall surface and below ground and floor level, fixing the pipe on wall surface with
the PVC clips including suitable rubber ring joints and solvent solution as per
manufacturer specification which includes bends, rubber ring, jointing, junctions,
clean out plug , cowls, offsets, collar, M.S holder-bat clamps, accesspiecestec . The
rate shall include cutting the pipes into required length wastage and testing as per
specifications, necessary earth work in excavation and filling of the pipe line trenches
providing staging and scafollding as per requirement at site.
GMRC Page 90 of
GMRC/CONS/DEPOT-2/2026 BOQ
4.2 Providing, fixing & testing uPVC pipes, conforming to IS 4985 class 3 (6 kg per sqcm)
including injection moulded fittings, jointing with solvent cement, cutting and making
good the floors and walls and jointing to trap/waste pipe, complete of outer dia.
4.3 Supply and Fixing PVC floor trap 100 x 75mm self cleansing design with or without
vent arm, Inlet receiving cap of 50 & 40mm Dia complete including cutting and making
good the walls and floors
4.4 Provide and fixing standard UPVC clean out plug with suitable insert key with all
required upvc accessories threaded adaper and end cap as per approval
4.4 Providing and fixing PVC SWR NAHANI TRAP IS 14735 for drain 100 mm dia with jali of Nos 371.09 42
the following nominal diameter of self cleansing design with C.I scread down or hinged
grating including the cost of cutting and making good the walls.
4.5 Supply and fixing SS hinged grating of 2mm thick 125mm dia with rim including setting Nos 176.5 42
in floor with cement mortar (approved type)
4.6 Supply and Fixing PVC Urinal trap 100 x 75mm self cleansing design with or without
vent arm, Inlet receiving cap of 50 & 40mm Dia complete including cutting and making
good the walls and floors
GMRC Page 91 of
GMRC/CONS/DEPOT-2/2026 BOQ
4.7 Providing and fixing square-mouth S.W. gully trap class SP-1 complete with C.I. grating
brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size
(inside) the weight of cover to be not less than 4.50 kg and frame to be not less than
2.70 kg as per standard design:
4.7.1 100x100 mm size P type Nos 2088.09 32
4.7.1.1 With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 Nos 2150.54 32
4.8 Providing and fixing of average thickness of 120 mm and minimum thickness at Nos 325.84 85
Rianwater khurra.
4.9 Providing, fabricating and fixing of MS plate 8 mm thick Puddle flange with all
4.9.1 100 mm dia Each 226.28 6
4.9.2 150 mm dia Each 362.04 6
4.9.3 200 mm dia Each 543.07 6
TOTAL OF SUB SCHEDULE 4: INTERNAL DRAINAGE (SOIL, WASTE, VENT AND RAIN
P 05 SUB SCHEDULE-5 : EXTERNAL SEWERAGE, EFFLUENT & STORM WATER DRAINAGE
External Sewerage
5.1 Laying and jointing glazed stoneware pipes Grade 'A' with stiff mixture of cement
mortar n the proportion of 1:1 (1 cement : 1 fine and) including testing of joints etc.
omplete: (Sewer upto 300 mm dia under normal conditions)
GMRC Page 92 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.2 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand :10 graded
stone aggregate 40 mm nominal size) up to haunches of S.W. pipes including bed
concrete as per standard design :
5.3 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
stone aggregate 40 mm nominal size) all-round NP2 pipes including bed concrete as
per standard design : (Sewer under road crossings and sub soil water conditions)
External Effulent
5.4 Supply and laying of following HDPE pipe under paved areas/track crossings including
necessary excavation & back filling complete as required.(For Effluent Pipes Under
normal conditions)
GMRC Page 93 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.5 Providing and laying cement concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded
stone aggregate 40 mm nominal size) all-round NP2 pipes including bed concrete as
per standard design : (Sewer under road crossings and sub soil water conditions)
5.6 Providing, laying, jointing and testing of following sizes of pipes conforming to IS-1239
part 1/1974 and part 11/1979 with all accessories like fittings with welded joint 'shall
be used like tees, elbows, reducers, flanges, rubber gaskets, GI nuts bolts, washer. And
fixing the pipe on embeded floor / /wall /ceiling with suitable size clamps, hangers to
be 'provided wherever the pipes are crossing the walls/floors and sealing). Including
cutting holes and chases in brick, R.C.C work and making good the same to original
conditions complete in (ETP Sump Pumping Line)
5.7 Constructing brick masonry circular type manhole 0.91 m internal dia at bottom and
0.56m dia at top in cement mortar 1:4 (1 cement : 4 coarse sand), inside cement
plaster 12 mm thick with cement mortar 1:3 (1 cement : 3 coarse sand) finished with a
floating coat of neat cement, foundation concrete 1:3:6 mix (1 cement : 3 coarse sand
: 6 graded stone aggregate 40 mm nominal size), and making necessary channel in
cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) finished with a floating coat of neat cement, all complete as per
standard design :
GMRC Page 94 of
GMRC/CONS/DEPOT-2/2026 BOQ
5.7.1 0.91 m deep with S.F.R.C. cover and frame (heavy duty, HD-20 grade designation) 560 Nos 10290.19 90
mm internal diameter conforming to I.S. 12592, total weight of cover and frame to be
not less than 182 kg., fixed in cement concrete 1:2:4 (1 cement : 2 coarse sand :
graded stone aggregate 20 mm nominal size) including centering, shuttering all
complete. (Excavation, foot rests and 12mm thick cement plaster at the external
surface shall be paid for separately) :
External Storm Water Drainage
5.8 Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars
jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine
sand) including testing of joints etc. complete :
5.8.1 100 mm dia. R.C.C. pipe NP2 RM 387.39 91
5.8.2 150 mm dia. R.C.C. pipe NP2 RM 430.83 4263
5.8.4 250 mm dia. R.C.C. pipe NP2 RM 703.27 4044
5.8.5 300 mm dia. R.C.C. pipe NP2 RM 805.55 1400
5.8.6 450 mm dia. R.C.C. pipe NP2 RM 1297.93 891
5.8.7 500 mm dia. R.C.C. pipe NP2 RM 1545.02 64
5.8.8 600 mm dia. R.C.C. pipe NP2 RM 1816.55 96
5.9 Providing and laying Non Pressure NP-3 class (Medium duty) R.C.C. pipes including
collars/spigot jointed with stiff mixture of cement mortar in the proportion of 1:2 (1
cement : 2 fine sand) including testing of joints etc. complete
5.9.1 450 mm dia RCC pipes. RM 2166.83 736
5.9.2 600 mm dia RCC pipes. RM 2782.31 18
5.10 Constructing brick masonry road gully chamber 50x45x60 cm with bricks in cement Nos 4855.91 690
mortar 1:4 (1 cement : 4 coarse sand) including 500x450 mm pre-cast R.C.C. horizontal
grating with frame complete as per standard design : With common burnt clay F.P.S.
(non modular) bricks of class designation
GMRC Page 95 of
GMRC/CONS/DEPOT-2/2026 BOQ
TOTAL OF SUB SCHEDULE 5 :External Storm Water Drainage (NDSR Item)
P 06 SUB SCHEDULE 6: WATER TREATMENT PLANTS AND MISCELLANEOUS ITEMS
Supply, erection, testing and commissioning including preparation of drawings of L.S 2796787 1
underground water treatment plant of capacity 122 m3/day based on attached
growth FAB technology for the following:
Daily Treated water requirement : 122 m3/day (Capacity 155000 Litre/day)
TOTAL OF SUB SCHEDULE 6: WATER TREATMENT PLANTS AND MISCELLANEOUS
P 07 SUB SCHEDULE 7: SEWAGE TREATMENT PLANT
Supply, erection, testing and commissioning including preparation of drawings of L.S 3262919 1
underground Sewage treatment plant of capacity 116 m3/day based on attached
growth MBR technology for the following:
Daily Avg. Sewage : 116 m3/day (Capacity 125 m3/day)
TOTAL OF SUB SCHEDULE 7: SEWAGE TREATMENT PLANT
P 08 SUB SCHEDULE 8: EFFLUENT TREATMENT PLANT
Supply, erection, testing and commissioning including preparation of drawings of L.S 3635824 1
underground effluent treatment plant of capacity 75 m3/day based on attached
growth FAB technology for the following:
Daily Avg. Effluent : 63 m3/day (Capacity 75m3/day)
TOTAL OF SUB SCHEDULE 8: EFFLUENT TREATMENT PLANT
P 09 SUB SCHEDULE 9: BOREWELLS (2Nos)
Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method L.S 2330656 1
prescribed in IS: 2800 (part I), including collecting samples from different strata,
preparing and submitting strata chart/ bore log, including hire & running charges of all
equipments, tools, plants & machineries required for the job, all complete as per
direction of Engineer -in-charge, beyond 90 metre & upto 150 metre depth below
ground level. (All types of soil)
TOTAL OF SUB SCHEDULE 9: BOREWELLS (2Nos)
GMRC Page 96 of
GMRC/CONS/DEPOT-2/2026 BOQ
P 10 SUB SCHEDULE 10: PUMPS AND RECHARGE PITS
10.1 Providing, fixing, testing and commissioning of Vertical in line type pump set with SS Nos 191801.7 1
casing, SS impeller and SS shaft suitable for operation on 400/440 volts, 3 phase
RPM, TEFC electric motor mounted on a common channel base plate with coupling
guard, 150mm dia pressure gauge, GM isolation cock and cement concrete foundation
with plaster complete as required.
a) Raw Water Pumps to Raw water OHT
Capacity 7.5 lps (Each)
Head 40 m (1W &1S)
10.2 Provding, installation, testing, and commissioning of factory assembled skid mounted Set 306881.8 1
Variable Freqency Drive Hydropneumatic system comprising of following items.
(Treated water supply).
a) 3 Nos. Vertical in line pumps complete in SS coupled with TEFC motor Pump
capacity - 550 lpm, Head - 60 m, RPM -
b) 1 No. 500 litres vessels with inter changeable butyl rubber membrane.
c) 1 No. Variable speed drive Electric control panel with controller relays, sequence
timer for alternate operation of pumps, electrical wiring, cabling
d) Accessories like butterfly valves, NRV's on suction and discharge, pressure gauge
suction, discharge header, PRV and base frame etc., complete as required.
e) Hydropneumatic system as described above.
GMRC Page 97 of
GMRC/CONS/DEPOT-2/2026 BOQ
10.3 Provding, installation, testing, and commissioning of factory assembled skid mounted Set 184129.1 1
Variable Freqency Drive Hydropneumatic system comprising of following items.
(Flushing water supply).
a) 2 Nos. Vertical in line pumps complete in SS coupled with TEFC motor Pump
capacity - 650 lpm, Head - 70 m, RPM -
b) 1 No. 500 litres vessels with inter changeable butyl rubber membrane.
c) 1 No. Variable speed drive Electric control panel with controller relays, sequence
timer for alternate operation of pumps, electrical wiring, cabling from panel to pumps,
level controller complete with all accessories as per manufacturer specifications.
d) Accessories like butterfly valves, NRV's on suction and discharge, pressure gauge
suction, discharge header, PRV and base frame etc., complete as required.
e) Hydropneumatic system as described above. (1W & 1S)
10.4 Provding, installation, testing, and commissioning of factory assembled skid mounted Set 214817.7 1
Variable Freqency Drive Hydropneumatic system comprising of following items.
(Irriagation water supply).
a) 2 Nos. Vertical in line pumps complete in SS coupled with TEFC motor Pump
capacity - 375 lpm, Head - 70 m, RPM -
b) 1 No. 500 litres vessels with inter changeable butyl rubber membrane.
c) 1 No. Variable speed drive Electric control panel with controller relays, sequence
timer for alternate operation of pumps, electrical wiring, cabling from panel to pumps,
level controller complete with all accessories as per manufacturer specifications.
d) Accessories like butterfly valves, NRV's on suction and discharge, pressure gauge
suction, discharge header, PRV and base frame etc., complete as required.
e) Hydropneumatic system as described above.(2W &1S )
GMRC Page 98 of
GMRC/CONS/DEPOT-2/2026 BOQ
10.5 Drainage Pump
Providing, fixing and commissioning non clog type mono block submersible drainage
pumps suitable for handling solids of 12 mm size with totally water and dust proof
motor as specified.
10.5.1 Pump Room Drainage Pumps Nos 340207.9 1
Capacity -500 lpm (Each)
10.5.2 Pits jack Drainage Pumps Nos 226805.9 1
Capacity - 225 lpm (Each)
10.5.3 Drainage Pumps for bogie wash plant Nos 226805.9 1
Capacity - 225 lpm (Each)
10.5.4 Drainage Pumps for IBL Sump Nos 226805.9 1
Capacity - 225 lpm (Each)
10.5.5 Drainage Pumps for IBL Sump Nos 316788.2 2
Capacity - 800 lpm (Each)
GMRC Page 99 of
GMRC/CONS/DEPOT-2/2026 BOQ
10.6 Recharge pits Nos 316788.2 8
Constructing recharge pit of 2.5 m dia & 4 m deep below ground level in brick
masonary in cement mortar 1:4 (1 cement:4 coarse sand) with Providing 20mm thick
cement plaster in single coat with cement morter 1:4, including necessary earthwork
in excavation in all kinds of soil,disposal of surplus excavated earth with all leads and
lifts, returning the earth in layers surrounding the brick work /pipes ramming and
watering etc., laying 200 mm thick plain cement concrete M10 in base ,150 mm thick
RCC top slab including steel reinforcement (Fe500 D) work in cutting ,hoisting and
laying in position required for gratings , ladders etc . Boring 300 mm dia bore upto
m from base of pit including the cost of transportation of boring machine to site and
taking back after completion of work. Supplying, assembling, lowering and fixing in
vertical position in bore well unplasticized PVC medium well screen (RMS) pipes(200
mm dia) with ribs, conforming to IS: 12818, including hire & labour charges, fittings &
accessories etc. all complete. Providing and fixing bail plug for 200 mm dia pipe.
Supplying and filling in 300 mm layers of boulders(50-200 mm size) in first layer, thick
gravel(5-10 mm size) in second layer and sand(1.5-2mm size) in third layer. Providing
and fixing precast RCC MH cover 560 mm dia with frame (Heavy duty HD-20) in top
slab. Complete as per drawings or as directed by Engineer-In-Charge.
TOTAL OF SUB SCHEDULE 10: PUMPS AND RECHARGE PITS
Total for Schedule D
GMRC Page 100 of
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
2. Volume - 1 ITT.pdf
3. Volume - 1 FoT.pdf
4. Volume -GCC.pdf
5. Volume - 2 SCC.pdf
7. Volume - 3 ERGS.pdf
8.1 Volume -4 TS - Civil.pdf
8.2 Volume -4 TS - PHE.pdf
8.3 Volume -4 TS - Arch.pdf
8.4 Volume -4 TS - EM_1.pdf
8.4 Volume -4 TS - EM_2.pdf
8.4 Volume -4 TS - EM_3.pdf
8.4 Volume -4 TS - EM_4.pdf
9. Volume - 5 Tender Drawings.pdf
1. Volume - 1 NIT.pdf
6. Volume - 2 SHE.pdf
10. Volume- 6 BoQ.pdf
Tender Drawings.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .