Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹3.2 LAccepted-AOC | L1 | Accepted-AOC lowest | |
| 2 | L2₹3.7 L+₹37,708.10 (11.4%)Rejected-Finance 5B FF NAND VIHAR AZAD NAGAR NEAR GODARA PETROL PUMP HISAR HARYANA 125001 | HISAR | HARYANA | 125001 | L2 | Rejected-Finance other than lowest. | |
| 3 | L3₹4.6 L+₹1.3 L (38.1%)Rejected-Finance | L3 | Rejected-Finance other than lowest. | |
| 4 | L4₹4.6 L+₹1.3 L (39.2%)Rejected-Finance | L4 | Rejected-Finance other than lowest. | |
| 5 | L5₹4.7 L+₹1.4 L (42.3%)Rejected-Finance | L5 | Rejected-Finance other than lowest. |
Tender Value
₹7.7 L
EMD Value
₹15,300
Closing Date
8 Apr 2020, 6:00 pmClosed
GE Ludhiana
Garrison Engineer Military Engineer services Near Jagraon Bridge Ludhiana 141001
SPL REPAIR / REWIRING OF BLDG NO P-119 AND P-91D (OTM ACCN ) AT DHOLEWAL UNDER GE LUDHIANA.
2020_MES_327970_1
GE/LDH-67/2019-20
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Dholewal under GE Ludhiana
Refer NIT and Tender Documents
9 documents required · 9 mandatory
₹500
GE Ludhiana
₹15,300
Yes
9 May 2020
24 Feb 2020
9 Apr 2020
24 Feb 2020
8 Apr 2020
2 Mar 2020
25 Feb 2020 - 29 Feb 2020
Amount
Taking down carefully copper/ aluminium point wiring (light, fan, socket or power) complete including fittings such as switches, ceiling rose, pendent holder, sketch fitting, sockets, regulator etc and making good disturbed surfaces of walls and floors etc to match with the existing complete all as specified & directed by Engineer-in- charge.
Taking down ceiling fan, any sweep and size, sealing cable, dismantling fan blades, re-assembling the ceiling fan and re-fixing in original position and making connections using new PVC insulated copper conductor cable of size 23/.0076 sqmm from ceiling rose to connector/ fan complete all as specified and directed by Engineer-in-Charge.
Painting to ceiling fan of any make/ model/ sweep by removing old paint and filling cavaties with filler and applying one coat of super enamelled paint of colour as per existing using spray gun and writing MES numbers with black paint complete all as specified and directed by Engineer-in-Charge.
Taking down exhaust fan, any sweep and size, sealing cable, dismantling fan blades, re-assembling the ceiling fan and re-fixing in original position and making connections using new PVC insulated copper conductor cable of size 23/.0076 sqmm from ceiling rose to connector/ exhaust fan complete all as specified and directed by Engineer-in-Charge.
Painting to exhaust fan of any make/ model/ sweep by removing old paint and filling cavaties with filler and applying one coat of super enamelled paint of colour as per existing using spray gun and writing MES numbers with black paint complete all as specified and directed by Engineer-in-Charge.
M&L point wiring complete with 1.5 Sqmm (nominal cross section area) FRLS PVC insulated unsheathed multistranded copper conductor cable in and including concealed heavy duty PVC conduit including cutting chases in walls and making good the disturbed surface with existing colour of wall all jointing accessories including provision of 3mm thick bakelite sheet top cover on new sunken boxes fixed with new brass screws & washers including 1.5 Sqmm FRLS, PVC insulated unsheathed stranded copper conductor wire as earth continuity to common earth and connecting to earth dolly for one light point/ bell point controlled by one switch or one fan point controlled by one switch through regulator complete all as specified and directed by Engineer-in-Charge.
All as per item No.6 above but for one 5 pin 5/6 Amps socket outlet on independent board.
All as described in Srl item No.6 above but for one 5 pin 5/6 Amps socket outlet on same board with other switch.
All as per item No. 6 here-in-before but with FRLS cable of cross sectional area 2.5 Sqmm for one socket outlet 15/16 Amps independent including 4 Sqmm FRLS, PVC insulated unsheathed solid conductor wire as earth continuity to common earth all as specified & directed.
S&F 18 Watt LED decorative ultra slim linear LED light fittings fixture with co extruded polycarbonate body, environmental enegy efficient including tube rod and connection from celing rose to connector complete with all acessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking out existing light fittings complete all as specified and directed by Engineer-in-Charge.Make Crompton Greaves cat part No LCTL-18-CDL for LED batten or LT5RT1-18-CDL for LED tube/ Bajaj / Philliips / Havells
S&F 10 Watt 600 mm T5 TL LED decorative ultra slim linear LED light fittings fixture with co extruded polycarbonate body, environmental enegy efficient including tube rod and connection from celing rose to connector complete with all acessories internally pre-wired and including connecting up with twin core twisted flexible copper conductor cable with suitable size including taking out existing light fittings complete all as specified and directed by Engineer-in-Charge.Make Crompton Greaves cat part No LCTL-9-CDL for LED batten or LT5RT1-9-CDL for LED tube / Bajaj / Philliips / Havells
M&L submain wiring with three single core FRLS PVC insulated unsheathed multistranded copper conductor cables of size 6 Sqmm FRLS PVC insulated copper conductor one run green insulation copper conductor cable as earth continuity drawn in and including medium grade PVC rigid non metelic conduit not less than 25mm dia with necessary conduit fittings concaeled in wall including cutting chases and making good the disturbed surface to match the existing surface including taking down existing submain wiring complete all as specified and directed by Engineer-in- charge. Make: Havells / Anchor / Finolex / Plaza
M&L submain wiring with three single core FRLS PVC insulated unsheathed multistranded copper conductor cables of size 4 Sqmm FRLS PVC insulated copper conductor one run green insulation copper conductor cable as earth continuity drawn in and including medium grade PVC rigid non metelic conduit not less than 25mm dia with necessary conduit fittings concaeled in wall including cutting chases and making good the disturbed surface to match the existing surface including taking down existing submain wiring complete all as specified and directed by Engineer-in- charge. Make: Havells / Anchor / Finolex / Plaza
Supply & fixing in replacement factory made sheet metal distribution boards, TPN, 4 way, double door; protection class IP-43 suitable for housing MCB conforming with 200 Amps rated copper bus bar suitable for working on 240 volts AC supply and making niche, replacement to match with existing surface etc complete all as specified and directed by Engineer-in-Charge. Make: Legrand/Havells/L&T/Hagger
Supply & fixing in replacement MCB TPN 415 volt, 40 Amp with rupturing capacity 10 KA, 50 Hz, 'C' series complete all as specified and directed by Engineer-in-Charge.Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply & fixing in replacement MCB Tripple pole (TP) 415 volt, 6-32 Amp with rupturing capacity 10 KA, 'C' series complete all as specified and directed by Engineer-in-Charge.Make: Standard /Havells/ Indo Asian / BCH / C&S
S&F in replacement factory made sheet metal enclosure for distribution boards, SPN, 8 way; double door with 200 Amps rated copper bus bar suitable for housing MCBs and working on 240 volts AC supply including making good to match with existing surfaces complete all as specified & directed by Engineer-in- charge.Make: Hagger/L&T/Legrand / Indo Asian
Supply & fixing in replacement MCB SPN 240 volt, 6-32 Amp, 50 HZ, 10 KA rupturing capacity 'C' series all as specified & directed by Engineer-in- charge. Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply & fixing in replacement MCB single pole 240 volt, 6 to 32 Amp, 50 HZ, 10 KA rupturing capacity 'C' series all as specified & directed by Engineer-in- charge. Make: Standard /Havells/ Indo Asian / BCH / C&S
Supply and fixing ceiling rose surface bakelite 65x 50mm with two or three terminal, polycarbonate /pvc/ isolated body all as specified and directed by engineer in charge.
Supply and fixing switch piano flush type single pole one way 5 Amps, 230 volts all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing socket outlet 3 pin,5 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing switch piano flush type single pole one way 15 Amps, 230 volts all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply and fixing switch socket combination two in one 3 pin 16 Amp flush type all as specified and directed by engineer in charge.Make: Anchor / SSK / Havells
Supply & fixing speed regulator for ceiling fan 1200mm/ 1400mm flush stapped type 230 volts complete all as specified and directed by Engineer-in-Charge.
Excavation in trenches n. exc 1.5 metre wide for taking out/ laying unseviceable of LT cable, pipe line etc. and not exceeding 1.5 metre deep and getting out in soft/ loose soil complete all as specified & directed by Engineer-in-charge.
Returning, filling in including spreading, levelling, watering and well ramming in layers not exceeding 25cm thick complete all as specified & directed by Engineer-in-charge.
Removal of excavated surplus spoil to a distance n.exc 50 metre and depositing where directed at level not exceeding 1.5 metre above the starting point complete all as specified & directed by Engineer-in-charge.
M & L sand cushioning for under ground cable 23cm thick (one layer of 8cm thickness before laying the cable and other layer of 15cm thickness after laying the cable) all as specified and directed by Engineer-in-Charge.
M & L brick protection with old size sub class 'B' bricks laid flat across the route of underground cable all as specified and directed by Engineer-in-Charge.
Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 1100 volts grade with aluminium conductor cross sectional area 25 sqmm 3.5 core laid in trenches/ ducts/ along poles/ through pipes including taking out existing cable complete all as specified & directed by Engineer-in- charge. Make: Havells / Polycab / CCI
Supply and fixing LED security light fitting LED 30 watt Epoxy coated cover sheet aluminium housing with heat resistant toughtened glass & IP 66 protection including taking out existing light fittings complete all as specified and directed by Engineer-in- charge. Make: Havells /CG/ Bajaj / Phillips
Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6mm thick burried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below ground level, earth plate surrounded by 15cm thick and packed layer of charcoal dust and common salt, connected to earth lead of GI wire 4 mm dia (8 SWG) by means of bolts, nuts and washers of the earth wire.galvanised iron or steel and thimbles and other end connecions to main switch board and protected by galvanised iron light grade 40mm dia pipe, 20mm dia pipe for water with funnel, wire mesh, PCC chamber in cement concrete (1:3:6) using 20mm graded stone aggregate and 50mm thick RCC cover (1:2:4) type B-1 using 20mm graded stone aggregate and 8mm dia TMT bar @ 10cm c/c both way including MS frame using MS angle of size 45mmx4mmx5mm complete all as specified and shown in electrical plate No-3 in MES Schedule (Part-I).Notes - (i) Outer edge of earth pit will be 1.5 metre away from the outer edge of PCC chamber. (ii) GI wire upto DBs earth connection is included in this item. (iii) Water pipe shall be provided in slantling position.(Earth wire and protection pipe upto 7.50m length is included in the unit rate)
SUN MANN ENGINEERS
JASSI TRADERS
JAY ANN CONSTRUCTION COMPANY
PARDEEP CONSTRUCTION COMPANY
PREM CONSTRUCTION COMPANY
Marwaha Builders
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .