Loading…
Loading…
Tender Value
₹42.8 L
EMD Value
₹86,000
Closing Date
15 Jul 2026, 6:00 pm5d left
GE (I) (CG) Gandhinagar
GE (I) (CG) Gandhinagar, G-252, sector-09, Gandhinagar-382007
PROVISION OF RETAINING WALL, STONE PITCHING AND BRICK WORK NEAR GATE NO 2 DSC AREA AT LEKHAWADA, GANDHINAGAR UNDER GE(I) (CG) GANDHINAGAR
2026_MES_774487_1
8217/E8
Open Tender
Civil Works
180 days
ICGS Gandhinagar
As per NIT
7 documents required · 7 mandatory
₹500
GE (I) CG Gandhinagar
₹86,000
Yes
24 Jun 2026
24 Jun 2026
17 Jul 2026
24 Jun 2026
15 Jul 2026
8 Jul 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Excavating over areas, n exc 1.5 m deep and getting out in soft /loose soil complete all as specified and directed. | 240 | CUBIC METER | - | - |
| 2 | Excavating over areas,exc 1.5 m but n.exc 3.0 m deep and getting out in soft /loose soil complete all as specified and directed. | 80 | CUBIC METER | - | - |
| 3 | Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth for foundation etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in soft/ loose soil complete all as specified and directed. | 36 | CUBIC METER | - | - |
| 4 | M&L Rough excavation not exceeding 1.5 m deep and getting out in soft & loose soil all as specified. | 300 | CUBIC METER | - | - |
| 5 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed. | 656 | CUBIC METER | - | - |
| 6 | Removing excavated material exc. 50m and not exc 50 m and depositing where directed at a level n exc. 1.5 m above the starting point complete all as specified and directed. | 300 | CUBIC METER | - | - |
| 7 | M&L for Plain Cement concrete1:4:8 (type D-2) ( using 40 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and directed. | 20 | CUBIC METER | - | - |
| 8 | M&L for RCC M-30 as in Foundations, including rafts, footings, foundation beams; slant beams; bases for columns, etc complete all as specified and directed. | 80 | CUBIC METER | - | - |
| 9 | M&L for RCC M-30 Walls, Retaining walls, basement walls, ballast walls and the like; any thickness; above top of footings; including attached pilasters and buttresses complete all as specified and directed. | 55 | CUBIC METER | - | - |
| 10 | M&L for Formwork to sides of concrete foundations, footings, bases of columns, raft and raft beams, sides and soffits (if any) of foundation and plinth beams; and similar work; vertical or to batter on flat surfaces complete all as specified and directed. | 140 | SQUARE METRE | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.31 MB
BOQ_867253.xls
BOQ • 0.25 MB
8217tender.pdf
Tender Documents • 0.93 MB
Download all tender documents and submit your bid