| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.5 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹19.1 L+₹36,765 (1.96%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹20.0 L+₹1.2 L (6.27%)Rejected-AOC | L3 | Rejected-AOC L3 | |
| 4 | L4₹21.3 L+₹2.5 L (13.5%)Rejected-AOC SARDARPURA 1ST B ROAD NEAR HANUMAN JI KA MANDIR JODHPUR RAJASTHAN 342 003 | JODHPUR | JODHPUR | RAJASTHAN | 342003 | L4 | Rejected-AOC L4 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
14 Oct 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) NO 02 JODHPUR
GE (AF) NO 02 JODHPUR
ADDN/ ALTN FOR IMPROVEMENT OF OTM BILLETS NO P-283 AND P-284 AT AF STN JODHPUR AND PROVN OF QTY-03 SHUTTER AT BUILDING NO P/390 AT 32 WING AF STN JODHPUR
2022_MES_552631_1
8331/E8
Open Tender
Civil Works
Item Rate
120 days
GE (AF) NO 02 JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
Yes
₹40,000
Yes
31 Oct 2022
17 Sept 2022
17 Oct 2022
20 Sept 2022
14 Oct 2022
1 Oct 2022
23 Sept 2022 - 27 Sept 2022
Amount
Demolition of cement concrete (un re-inforced) in ground floor and paving n.exc. 15 cm thick below or above ground level complete all as specified .
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and as directed.
Dismantling PVC drain or vent pipe of any description in any position including bends branch pieces etc complete all as specified and as directed.
Taking down cement plaster on brick wall surfaces etc incl raking out joints hacking for key, scrubing down with water etc complete all as specified and as directed
Dismantling floor, hearth or wall tiling incl cement mortar bedding (but not backing) and rubbish off the premises complete all as specified.
Taking down chowkhats or frame with shutter (without taking off shutters from the frames) n.exc. 1.5 Sqm complete all as spd and as directed.
Taking down chowkhats or frame with shutter (without taking off shutters from the frames) exc. 1.5 Sqm but n exc 4.00 sqm complete all as spd and as directed.
Taking down and Refixing in Shutters of any description but exc 1 sq. m and n exc 2 sq. m each complete all as specified and as directed
Resecuring or easing & adjusting without taking down shutters of any description exc. 1 sqm but n. exc. 2 sqm each complete all as specified and as directed
M&L rendeing 15mm thick stone masonry,other then fair faces surfaces in CM 1:6 finished even and smooth with out using extra cement (Internal surfaces) complete all as specified and as directed
M&L rendering 10mm thick in CM (1:3) on stone masonry fair faces of concrete surfaces as in ceilling finished fair and even without using extra cement complete all as specified and as directed
M&L rendeing 15mm thick rendering on stone masonry in CM 1:4 on walls using integral water proofing compound @3% weight of cement finished even and smooth with out using extra cement and all as specified. (Note :- Water profing compound shall be measured and paid seperately)
Supply only integral water proofing compound ISI Marked and complete all as specified and as directed
M&L for joint free non skid ceramic tiles, coloured, 7 to 8 mm thick in floors etc. (square/rectangular) area of each tile exc. 0.06 sqm but n. exc. 0.11 sqm, set & jointed in neat cement slurry & pointed in white or coloured cement to match over and including 10mm thick rendering on stone masonry in CM 1:4 on walls complete all as specified and as directed
M&L for coloured glazed ceramic tiles in vertical surface 350 x 250 x 7mm / 450 x 350 x 7mm thick set & jointed in neat cement slurry and pointed in white or coloured cement to match including 15mm screed bed in 1:6 cement mortar complete all as specified & as directed.
S&F framed work such as grills, gratings, etc with ends of bars shouldered and / or riveted, or forged into spikes , framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings , framework of water tanks and similar work conforming to Fe 290 Gde E-165 complete all as specified and as directed.
S&F in repair galvanised mild steel wire cloth, 0.63mm nominal dia of wire and average width of aperture 1.40mm and fixed with tinned tacks, or galvanised wire staples complete all as specifed.
M&L for hacking out old broken glass (any thickness, size, quality or description) from metal frame glazed with putty including punching or drilling out old glazing pin/spring, clips and providing new ones complete all as specified and as directed.
S&F sheet glass , ordinary quality & glazing 3mm thick, with oil putty in square n. Exc 0.5 Sqm in each pane complete all as specified & as diretced
S&F figured glass 4mm thick, pin head type and glazing with oil putty in square n. Exc 0.5 Sqm in each pane complete all as specified & as diretced
S&F factory made solid PVC door frame of size 50mmx47mm made out of 5mm wood grain printed PVC sheet reinforced with mS square tube etc complete all specified.
S&F Factory made solid panel PVC door shutter 30mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails, M.S. frame shall be covered with heat moulded plain colour PVC `C' channel heaving a PVC sheet strip of 20mm width suck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Panelling of plain colour PVC sheet to be fitted in the M.S frame wedded/ sealed to the stiles, & rails with suitable PVC sheet beading, and joined together with solvent cement, complete all as specified & directed.
S & F in repair 20mm dia anodised aluminium alloy curtain rails with fixing brackets etc complete all as specified
Supply and fixing stainless steel butt hinges medium weight , clod rolled, 100mm, ISI marked, complete all as specified & directed.
Material & Labour barrel tower bolts aluminium anodised extruded section of size 200 mm complete all as specified & directed.
Supply and fixing aluminium fabricated type extruded handles of size 150 mm complete all as specified & directed.
M&L for applying two coat of Oil emulsion distemper (tint as approved by GE)including prepration of newly plastered wall surface and over a layer of one coat of wall putty complete all as specified.
M&L for complete removal of old treatment by mechanical means from walls and applying one coat of acrylic two coats of wall putty and sanding and applying two coats of oil bound destemper white or tinted by pump roller applicator as directed.
M&L for prepration of New plastered or unplastered surfaces of walls and applying two coats of cement base paint white or tined allas specified.
M&L for preparation of New plastered or unplastered surfaces of ceiling and applying two coat of white wash.
M&L for complete removal of existing treatment of walls and applying two coats of cement base paint over a coat of primer and white or tined all as specified.
M&L for preparation of old plastered or unplastered surfaces of ceiling and applying one coat of white wash complete all as specified and as directed.
M&L for preparation of old plastered or unplastered surfaces of walls and applying two coat of white wash complete all as specified and as directed.
M&L for one coat of synthetic enamel paint over a coat of red oxide including preparation of old steel surfaces all as directed.
M & L Preparation of old or previously untreated surfaces of wood or based materials of any description not otherwise described, over 10cm width or girth and applying one coats of synthetic enamel paint complete all as specified.
M&L for powder coated anodised aluminium frame for door window & ventilator with one or more rebates including joining cleat for fixing etc comlete all as specified.
Taking up or down 15 mm dia steel tubing and connection and removal from site complete all as specified and as directed
All as per item No.37, but 20mm dia complete all as specified and as directed.
S&F steel water tubing medium grade galvanized with all fittings and fixed complete to walls (concealed type) and ceiling or laid into floor or 15mm bore complete all as spd.
All as per item No.39, but bore of pipe 20mm
S&F steel water tubing medium grade galvanized with all fittings and fixed complete to 40mm bore complete all as spd.
Refixing old 15mm GI tubing and connections on new or old position (walls, ceilling, floor etc) complete all as specified and as directed.
Refixing old 20mm GI tubing and connections on new or old position (walls, ceilling, floor etc) complete all as specified.
S&F in repair 15mm dia Bib tap chromioum plated long body handles screwed with wall flange for iron pipe and fixed complete all as specified and as diredcted.
Supply & fixing wash hand basin, vitreous china, white, decorative type, flat or angle back, size 550mm x 400mm incliding cutting for and pinning in ends of brackets or erecting stand including waste pipe , fixed as in repairs complete all as specified.
Supply and fixing vitreous china urinal, half stall type, of size 600 x 355 x 265mm, white (excluding flushing cistern, flush pipe), but including waste pipe fixed as in repair, complete all as specified.
S & F 15mm pillar tap cast copper aloy with capston heads chromium plated screwed down fly nuts screwed for iron pipe or for brass ferrule and fixed complete all as specified.
S&F grating doom 100 mm dia of PTMT (Min wt 25g) all as specified and as directed
S & F PVC waste pipe 32mm bore of suitable length for WHB/Urinsl/sink complete all as specified and as directed
Dismantling water tanks exc 500 ltrs but n exc 1000 ltrs cap and removing to store complete all as spd.
Disconnecting existing water tanks exc 500 ltrs but n exc 1000 ltrs cap setting aside (or lowering if required) for repair cleaning etc and hoisting if required reconnecting and refixing in position. (cleaning repairing etc measured separartely) tanks exc 500 ltrs but n exc 1000 ltrs cap and removing to store complete all as spd.
Disconnecting existing water tanks n exc 500 ltrs cap setting aside (or lowering if required) for repair cleaning etc and hoisting if required reconnecting and refixing in position. (cleaning repairing etc measured separartely) tanks exc 500 ltrs but n exc 1000 ltrs cap and removing to store complete all as spd.
S&F 1000 ltr cap ratational moulded polythene water stoarage tanks ( clyndrical vertical with closed top) hoisted and fixed in position complete all as spd.
S & F 20mm bore dia ball brass valves, high pressure with polythene float and flynut complete screwed for iron pipes etc, complete all as specified.
S&F of flushing cistern PVC 10 ltrs cap valve less syphonic action type, low level white with intel , ball valve , float incl brackets and PVC flush pipe 32mm dia complete all as specified. .
Supply and fixing angle/stop valve, chromium plated, brass fancy type, screwed down, high pressure with crutch or butterfly handle screwed down , screwed for iron pipe or for union, suitable for 15mm bore pipe, fixed as in repair complete all as specified and directed.
S&F as in repair 15mm angle/stop valve, fancy type,chromium plated with long shank and cup (Concealed type) screwed down high pressure with crutch or butterfly handle screwed both ends for iron pipe complete all as specified and directed.
Supply and fixing 15mm dia PVC connection with brass nut, of length 600mm, in repair complete all as specified and directed.
S & F vitreous china squatting pan, "Orissa Pattern" size 580 x 440mm white with integral foot rest (excluding flushing cistern) and flush pipe complete all as specified
S&F in repairs, EWC vitreous china wash down water closet pan (pedestal pattern), white, with and including plastic water closet seat, closed pattern with flat bottom, and cover and mild steel chromium plated or aluminised hinging device fixed complete all as specified.
S & F chromium plated shower rose (125mm) with swivel joints fixed to steel pipe or union complete all as specified and directed.
S&F 110mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including clamps as required complete all as specified.
S&F 75mm dia PVC (SWR) pipes single socketed in any length with rubber ring joints fixed to wall including clamps as required complete all as specified.
S&F 75mm dia PVC (SWR) bends with oval accesse door with rubber ring joints fixed as required complete all as specified.
S&F 75mm dia PVC (SWR) junction single, (single T), equal or un equal with oval accesse door including jointing with solvant cement as required complete all as specified.
S&F 110mm dia PVC (SWR) junction single, (single T), equal or un equal with oval accesse door including jointing with solvant cement as required complete all as specified.
S&F 110mm dia PVC (SWR) branch piece (Single-Y) equal or un equal of any length including jointing with solvant cement as required complete all as specified.
S&F 75mm dia PVC (SWR) branch piece (Single-Y) equal or un equal of any length including jointing with solvant cement as required complete all as specified.
S&F 75mm dia PVC (SWR) vent cowl, single, equal or un equal of any length including jointing with solvant cement as required complete all as specified.
S&F PVC (SWR) floor trap with garting of outlet dia 75mm incl jointing with solvent cement complete all as specified and as directed
Cutting holes into or through stone walls built in CM mud mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B-l, superficial area n exc 150 sqmcm complete all as specified and as directed
Material and labour for water proofing treatment of sunken floor of WCs, bathroom etc. by applying of the following specifications :- (i) Cleaning of sunken floor surface with mechanical means i.e. wire brush/air blower etc. and remove all loose/unsound material, dirt, dust, etc.(ii) Applying cement slurry mixed with acrylic based polymer modified cementitious composite compound coating Hydroproof Xtra of FOSROC/Equivalent of Dr Fixit of Pidilite Industries Ltd in the ratio of 1:2:4 (One part of acrylic polymer : Two part of water and four part of cement).(iii) First layer of cement slurry @ 0.444 Kg/Sqm mixed with acrylic based modified cementious composite compound @ 0.222 Litre/Sqm and allow it to air dry for 04 hours.(iv) Second layer of cement slurry @ 0.222 Kg/Sqm mixed with acrylic based polymer modified cementitious composite compound @ 0.111 Litre/Sqm and allow it to air dry for 04 hours followed with water curing for 48 hours.(v) 200 micron thick polythene film shall be pasted with help of adhesives over treatment.Note :- Joints of WC/Trap/Soil waste shall be properly sealed with sealing compound. Testing of all traps and joint and sunken slab shall be done as per IS-1742 before filling and tiling work complete all as specified.
Material and labour for plain cement concrete 1:5:10 type E-2 (using 40mm graded broken bricks aggregate) as in foundation, filling and mass concrete, complete all as specified and as directed.
Material and labour for 25mm thick plain cement concrete 1:2:4 type B-0 (using 12.5mm graded stone aggregate) as in levelling courses laid and compacted in slope in floor complete all as specified and as directed.
M&L for poviding and injecting chemical emulsion for post construction anti termite treatment along external wall where the apron is not proving using chemical emulsion at theart of 7.5 ltr per sqm of the vertical surface of the sub structure to a depth of 300mm including excavating channel along the wall and rodding etc complete all as specified and directed.
M&L for treatment of soil under existing floors using emulsion @ one litres per hole 300mm apart including drilling and plugging 12mm dia holes with cement mortar 1:2 to match the existing floors and all as specified and directed.
Wire brushing and cleaning top surfaces of tarrace or cement concrete including flashing and junction of parapets, complete all as specified and as directed
M&L 10 mm thick plaster with CM 1:4 with water proofing compound @ 3% by weight of cement finish even and smooth surfaces using without extra cement. Water proofing compound shall be measured and paid seperately, complete all as specified and as directed
M/L for cement concrete B-0. 1:2:4 (12.5mm graded aggregate) in padding finishing surface of concrete topping even and fair without using extra cement all as specified of average thickness 25 mm in slop 1:40 over roof, complete all as specified and as directed
M/L for providing APP based polymeric membrane minium weighting 3 Kg/Sqm and minimum 3mm thick reinforced with polyster non wave fabric ( weight not less than 150 gms/sqm ) land over a coat of primed surfaced by forced application and complete all as specified and as directed by Engr-In-Charge.( Note : Quoted rate shall be deemed to be included for work in building/structure of any height) overlapped by 100 mm in all sides as directed by Engr-in-Charge
S&F metalic louvers slits frame to receive glass stripof size 300x450 mm with including arrangement of fixing glass pinhead as per size & louvers ventilator (Glass shall be measurement separately) complete all as specified and as diredcted.
S&F steel rolling shutters thickness 1.25mm with out ball bearing, as specified including top cover anchoring rod hasp and staple and one shop coat of primer erected in postion nas indicated complete push pull or manual type complete all as specified and as directed by EIC
M&L for preparation of new steel surface of any description not otherwise provided over 10 cm width or girth and applying two coats of synthetic enamel paint and complete.
Taking down carefully copper/aluminum point wiring (Light/ fan, socket or power) complete, including fixture and fittings such as switches, ceiling roses, pendants, regulators, sockets, light fitting etc, stacking at site for reuse or removing materials to store for keeping in for taking credit and making good the disturbed surfaces / walls/ floors etc,.
M&L for channel or grooves cutting upto a depth of 2.5 cm and width not exc 15cm into brick/concrete/stone masonary walls, with or without re-inforcement and trimming surface as required, including concealing PVC conduit 20/25mm dia with required accessories (like junction boxes/bends etc) and plastering in 1:4CM, applying two coats of approved quality white putty for making good with smooth finish to match with the existing specification of wall surface all specified and directed by engr-in-charge. Note : Rate of PVC Conduit included in relavant point wiring and shall not be paid separately.
M&L for point wiring with 1.5 Sq. mm, multi-stranded copper conductor, single core, PVC insulated and unsheathed cable for phase and neutral, including 1.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly, drawn in surface/concealed conduit Heavy duty (HMS Grade), GI terminal boxes not less than 1.0mm thick fixed flush to wall surface, covered with & including 3 mm thick plastic laminated sheet top cover or including modular plates of required size for mounting switch and sockets etc. complete all as specified and directed for following : - Note : Quoted rates deems to be included cost of modular plate or hylem board for mounting switches, sockets & regulators as required at site. Cutting into chases required for concealing heavy duty (HMS Grade) PVC conduits and making good to damaged surface shall be measured and paid separately under relavant item.
(a) One light / fan point controlled by one switch one way.
(b) One 3 pin 5 Amp switch & socket outlet on same board with other switches.
(c) One 3 pin 5 Amp switch & socket outlet on Independant board.
All same as per item ser No 2 here-in-above but wiring using 2.5 sqmm multi-stranded copper conductor, single core, PVC insulated and unsheathed cable, including 2.5 Sq. mm PVC insulated unsheathed multistranded copper conductor single core cable as earth continuity conductor (in green color) connected to common earth dolly for 6 pin, 15/16 Amps socket outlet on independant board.
S&F switch modular single pole one way 6 Amps 230 volt 1 module.
S&F switch modular single pole one way 16 Amps 230 volt 1 module.
S&F Socket modular 6 Amp 2/3 pin combined two module.
S&F Socket modular 6&16 Amp 2/3 pin combined two module.
S&F Ceiling rose surface bakelite 65x50mm three terminal.
S&F Stepped type electronic fan regulator, socket size, flush type 230V AC.
S&F Lamp holder insulated PVC/Polycarbonate/bakelite body, fixed on PVC round or squre box using necessay screw & gutti complete all as specified.
S&F (in repairs) modular white or Ivory cover plate with frame 1 module
S&F (in repairs) modular white or Ivory cover plate with frame 2 module
S&F (in repairs) modular white or Ivory cover plate with frame 3 module
S&F (in repairs) modular white or Ivory cover plate with frame 4 module
S&F (in repairs) modular white or Ivory cover plate with frame 6 module
S&F (in repairs) modular white or Ivory cover plate with frame 8 module
S&F (in repairs) modular white or Ivory cover plate with frame 12 module
Fixing only light fitting any type, connecting up with twin core PVC insulated and PVC sheathed flexible copper conductor cable of suitable size from ceiling rose complete all as specified. Note : Serviceable light fittings taken down against item No 83 shall be used at site as directed by engr-in-charge.
Supply and fixing LED light fitting wall /roof mounted, 1 x 20 watt including LED tube with driver complete suitable body robust, corrosion resistant, superior finish and without any cracks or through holes. The system wattage of fitting should not be more than 20 watt ± 10%, surge protection of minimum 2 kV power factor should be more than 0.90 cool white colour, total harmonic distoration (THD) should not be more than 15%, lumen output should not be less than 90 lumens per watt, total input voltage range 140-280 V AC, colour rendering index should not be less than 80, corelated colour should be minimum 6000 degree kelvin complete all as specified and directed.
Supply and fixing LED study table light fitting, swivel base, wall mouning type, corrosion resistant, superior finish and including 01 Nos 5 watt LED lamp B-22 Base type, complete all as specified and directed.
S&F Building security light fittings, with pressure die cast aluminium housing, suitable for 25 W LED, complete pre-wired, incl suitable bracket for fixing light on wall or any indicated locaction all as specified and as directed by Engr - in Charge complete all as
Taking down carefully Ceiling fan/Exhaust fan by disconnecting electrical connections, unsecrewing from position, stacking carfully at site for reuse of serviceable fans or dismantling blades and removing fan and blade to E/M Store yard all as directed and specified.
Hanging only ceiling fans, 1200mm sweep, complete with three blade, down rod, accessories and making connection from ceiling rose or connector to fan using three core 0.75sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire complete all as specified. NOTE: Serviceable ceiling fans taken down agaist item No 18 shall be re-used after necessary cleaning and serving at AGE E/M store yard.
Fixing only exhaust fan 300/450mm sweep, Steel/PVC body AC single phase 230V of size 300m using 4 Nos 10mm x 100mm long wall fasteners, nut and washers and connecting up using flexible three core 0.5sqmm copper stranded conductor PVC insulated and PVC sheathed flexible wire through PVC flexible conduit from ceiling rose/connector to fan complete all as specified. NOTE: Serviceable exhaust fans taken down agaist item No 18 shall be re-used after necessary cleaning and serving at AGE E/M store yard.
S&F ceiling fan of 1400 mm sweep, induction motor type, heavy duty cast aluminium body, BEE approved ISI marked, single phase, AC supply, 240 Volt, including canopies, three number aluminium blades, down rod, double ball bearing with capacitor of 2.5 mfd and making connection with and including PVC insulated PVC sheathed copper conductor flexible cable from ceiling rose or connector to fan including marking of MES number complete all as specified and cat Part No TECHNIX PLUS of Make USHA or equivalent in approved makes. NOTE:The length of suspension rod shall be as per site requirement.
S&F Exhaust fan 450 mm sweep, heavy duty, metal body, four blade, air delivery shall not be less than 350 CFM at 1450 RPM mounted in suitable opening arrangement with louvers shutters suitable for operation on 240 volt, single phase, 50 cycle per second, AC supply and connecting up including provision of flexible PVC conduit from ceiling rose or connector to fan to cover PVC cable including marking of MES number and fixed in position as recommended by manufacturer complete all as specified.
M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 4.0 Sq.mm main cable alongwith one run of single core 4.0 Sq.mm for continuous earth wire in green color.
M&L for Sub main wiring with approved colour coding as per IS, single core FRLS PVC insulated flexible multistranded copper conductor 1.1 KV grade drawn through & including PVC grey conduit heavy duty with necessary accessories (like bend, juction boxes etc) including taking down old unsv submain wiring complete all as specified for Two runs of 6.0 Sq.mm main cable alongwith one run of single core 6.0 Sq.mm for continuous earth wire in green color.
Supply & fixing cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured electric power cable heavy duty with stranded aluminium conductor 1100 volts grade of size 10 Sqmm 2 core by using GI saddles, screws and gutti on stone masonary wall from Mains DB to Solar water heaters complete all as directed and specified.
Supply and replace sheet metal enclosures with socket plug top, and MCBs single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB upto 20 Amps, 240 Volt capacity fixed flush to wall surface including making good to damaged surface of wall to match with existing specification and tested on completion complete including taking out old all as directed.
Supply and fix Sheet metal enclosure distribution board TPN, 415 volts, 4 way Horizontal/vertical type as per site requirement, double door type, 200 Amps rated neutral copper bus bar for housing MCBs, blank plates and including provision for fixing TPN MCB as incommer, DB fixed flush or in wall surface including making good to damaged surface of wall to match with existing specification complete including taking out old all as specified all as specified and directed. Note : MCB SP/SPN/TPN will measured and paid separately under relavant item.
Supply and replace sheet metal enclosure distribution board for 240 volts, 8 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
Supply and replace sheet metal enclosure distribution board for 240 volts, 12 way horizontal type, double door, single pole and neutral with 200 Amps rated neutral copper bus bar for housing MCB and blank plates and fixed flush in wall surface, and tested on completion complete including taking out old all as directed.
M&L for MCB TPN/FP, 40 to 100 Amps 415 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
M&L for MCB SPN/DP 40 to 63 Amps 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified.
Supply and fixing MCB single pole 6-32 Amps, 240 volts, 10 kA rupturing capacity providing in DB complete including connection & testing all as specified. Note for MCBs : Current rating of MCBs shall be provided as per electrical load of circuits as specified & directed
Material and labuor for earthing complete with Galvanized Steel earth plate electrode 600x600x6mm thick buried directly in ground (earth pit not less than 2.25 M deep below ground level) with top edge of the plate not less than 1.5 M below normal ground level and filled with 15cm thick alternate layers of charcoal and salt, connected & including GI wire earth lead 4.0mm dia by means of bolts, nuts, check nuts and washers made of galvanized iron protected by 15mm dia GI Pipe (light grade). Earth plate shall be surrounded by alternate layers of charcoal or coke and common salt in 15cm thick in layers & 15cm of widht all aurround of earth plate including 20mm dia GI light grade pipe for watering and including funnel, wire mesh, necessary earth work in any type of soil, Pre-cast RCC cover duly re inforced with 8mm dia TMT Bar @150 mm c/c both ways, one lifting handle made of 8 mm dia TMT bar embedded in cover slab, Earth Pit of PCC (1:3:6) type C2 (using 20mm graded crushed store aggrgate) complete all as specified and as shown in electrical plate No-3 of SSR Part-I including testing on completion. Note:- (i) PCC chamber shall be constructed at least 1.5 metre away from the earth electrode and pipe for watering shall be provided in slanting manner. (ii) The unit rate includes earthing lead & protection pipe upto 7.5 metre from top of earth plate.
Bansal Enterprises
M/s Pal Builders
VIKAS CONSTRUCTION CO.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .