Loading…
Loading…
| # | Company | Quoted % | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹1.8 CrAdmitted-Finance | -23.57% | ₹1.8 Cr | L1 | Admitted-Finance |
| 2 | L2₹2.0 CrAdmitted-Finance | -13.90% | ₹2.0 Cr | L2 | Admitted-Finance |
| 3 | L3₹2.0 CrAdmitted-Finance | -12.90% | ₹2.0 Cr | L3 | Admitted-Finance |
| 4 | L4₹2.3 CrAdmitted-Finance | -0.10% | ₹2.3 Cr | L4 | Admitted-Finance |
| 5 | L4₹2.3 CrAdmitted-Finance | -0.10% | ₹2.3 Cr | L4 | Admitted-Finance |
Tender Value
₹2.4 Cr
EMD Value
₹2.4 L
Closing Date
24 Mar 2026, 4:00 pmClosed
CCE Keonjhar (R and B) Circle
O/o the CCE Keonjhar (R and B) Circle, keonjhar-758001
Construction of 4 Nos of D-type (S plus 1) quarter for project (R and B) Sub-Division at Sundargarh Division for the year 2025-26
2026_EICCL_127002_1
CCEKC - 21 / 2025-26
Open Tender
Civil Works - Buildings
210 days
Sundargarh
Please refer Tender Documents
4 documents required · 4 mandatory
₹10,000
₹2.4 L
Yes
4 Jun 2026
10 Mar 2026
25 Mar 2026
10 Mar 2026
24 Mar 2026
10 Mar 2026
Civil Work WORKS (PART-I) Earthwork in excavation of foundation in hard soil or gravelly soil within 50m initial lead and 1.5m, initial lift including shoring,shuttering, propping bullahs, piling,dewatering from foundation, with & working pumps & staking the excaveted materials away from the working area including rough dressing the bed and foundation tranches to required size including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge
Providing and laying plain cement concrete (1:3:6)(using branded cement) in foundation using 40 mm size hard crusher broken granite metal of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes,cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,complete as per the direction of the Engineer-in-charge.
Providing lifting , hoisting and laying Reinforced Cement Concrete of M 20 grade(using branded cement) to the following structural member or in places as shown in the drawing for all floors with 20 mm and down graded size hard crusher broken granite chips of approved quality from approved quarry including mixing and vibro compacting to proper shape and size, level and plumb and finishing the exposed surfaces smooth (if required by grouting / providing plaster with cement mortar 1:4 wherever necesary without any extra cost) scaffolding, including watering and curing for the required period including providing strong, rigid, levelled and plumbed centring and shuttering to required shape and size, for floors with wood/Steel centring materials, with all necessary bracing and ties and supports pockets for electrical conduits, pipes, PH pipes, for hooks or boxes, switchboards and insert plates, clamps and extension bars, etc, including dismantling the same after the required interval from the date of casting, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering,curing, sundries. tools and plants etc. complete as per direction of the engineer-in-charge, but excluding cost of steel reinforcement. i) R.C.C Column Base, Footing
ii) R.C.C Plinth Beam
iii) R.C.C Column & Beam in Superstructure a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
iv) R.C.C Lintel a) 1st Floor
v) R.C.C Chajja (6.5 cm average thick) a) 1st Floor
vi) R.C.C Staircase a) Ground Floor
b) 1st Floor
v) R.C.C Shelves a) 1st Floor
vii) R.C.C Roof Slab a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Fly Ash brick masonry in cement mortar (1:6) (Using Branded Cement) in foundation & plinth using Fly Ash bricks of 23x11x 8 cm size having a crushing strength of not less than 75 kg./sqcm with dimensional tolerance ± 2% including splays cutting circular moulding chamfering and corbelling and similar such type of works with all necessary projections watering and curing after immersing the bricks in water at least for six hours before use including cost, conveyance, royalties and taxes of all materials with all labour,labour cess and T & P required for the work complete in all respect as per specification & direction of Engineer-in-charge.
Providing Fly Ash brick masonry work in super structure using 23 X 11 X 8 cm (with dimensional tolerance of ± 2% ) Fly Ash bricks having crushing strength not less than 75 kg. / sq cm, mortar of mix 1:6 (1 cement : 6 sand),(using branded cement) immersing the bricks for minimum 6 hrs in water before use, with all necessary projections, splay cutting, circular moulding, corbelling, etc., including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants,etc., complete as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Supplying steel i.e. Tor Steel / HYSD Bars conforming IS-1786 including straightening, cutting, bending, binding, welding and jointing if necessary and tying the grills and placing in position as required for R.C.C. Work and providing fan hooks as required, hoisting, lowering, laying including cost, conveyances, taxes tor steel and binding wires of 18 to 20 gauge and labour required for the work for bending, binding and tying the grills in all floors with labour cess etc. (Linear measurement will be taken and quantity will be calculated on standard weight of tor steel / HYSD bars for all heights) complete as per specification & direction of Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Providing 12 mm thick cement mortar 1:6 (1 cement : 6 sand )(using branded cement) to outside surface / plumbed surface of masonry, raking out joints, scrapping and cleaning the surface and finishing the plastered surface smooth to proper plumb and levels and providing grooves or beads where ever necessary, including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, watering. curing, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Providing 16 mm thick cement plaster with cement mortar of mix (1:6) (Using Branded Cement) with screened and washed sharp sand for mortar and finished smooth to the inside rough surface of walls in all heights after racking out joints including watering and curing, rounding of corners, providing grooves or beads where ever necessary with cost, conveyance, royalties and taxes of all materials with cost of all labour,labour cess, T&P, and scaffolding required for the work etc. complete in all respect as per specification & direction of Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Supplying and filling in foundation and plinths with sand well watered and compacted including cost of all materials, labour, conveyance, loading and unloading, taxes, cess, royalties, watering, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge.
Providing Kota tiles of sizes above 0.10 sqm having minimum thickness 16mm of approved make and shade, dressed, rubbed and polished, bottom coated with neat cement slurry in floor ,treads or steps and landing fixed with neat cement slurry, over 25 mm thick cement mortar (1:1)(1 cement : 1 sand) (Using Branded Cement) to masonry or concrete surfaces to proper level / slope and joints filled with cement mixed with matching matching to the shades of the tile/stone in required proportion, polishing, washing and acid cleaning, including cost of all materials, conveyance, royalties, taxes,cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per specification & direction of the Engineer-in-charge. a) Ground Floor
Providing Kota tiles of sizes above 0.10 sqm having minimum thickness 16mm of approved make and shade in dados skirting and rises of steps to any height in all floors, fixed with neat cement slurry, after soaking the tiles in water, over 12 mm thick cement mortar (1:3)(1 cement : 3 sand) mix, joint pointed with cement mixed with matching pigment to match the shade of the tiles , including washing and cleaning with oxalic acid, including cost of all materials, conveyance, royalties, taxes,cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. a) Ground Floor
Providing Granite Tiles of sizes Above 0.40 Sqm. (20mm thick) of approved make and shade, dressed, rubbed and polished, bottom coated with neat cement slurry in Stair case, Tread, Riser, Landing, Kitchen Slab Floors fixed with neat cement slurry, over 25 mm thick cement mortar (1:1)(1 cement : 1 sand) (Using Branded Cement) to masonry or concrete surfaces to proper level / slope and joints filled with cement mixed with matching colour in required proportion, polishing, washing and acid cleaning, including cost of all materials, conveyance, royalties, taxes, cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
Providing Granite Tiles of sizes Above 0.40 Sqm. (20mm thick) of approved make and shade, dressed, rubbed and polished, bottom coated with neat cement slurry in dado skirting & risers of steps fixed with neat cement slurry, on 12 mm thick cement mortar (1:3)(1 cement : 3 sand) (Using Branded Cement) to masonry or concrete surfaces to proper level / slope and jointed with cement slurry mixed with matching colour in required proportion, polishing, washing and acid cleaning, including cost of all materials, conveyance, royalties, taxes, cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
Supplying, fitting and fixing Industrial vitrified tiles in floor treads or steps and landing of premium grade having thickness 8mm to 10mm of size 300mm x 300mm confirming to IS 4457 of approved make on 20mm thick bed of C.M. (1:4) (Using Branded Cement) including cost of all materials, taxes, cess, labour, T&P etc. required for the work in all respect as per specification & direction of Engineer-in-charge. a) Ground Floor
Providing and laying plain cement concrete (1:2:4)(using branded cement) in superstructure using 12 mm size hard crusher broken granite chips of approved quality from approved quarry including mixing, lowering, laying and compacting to proper thickness, watering and curing for the required period including cost of all material, labour, conveyance, loading and unloading, taxes, cess,royalties, scaffolding, watering, curing, sundries, tools and plants,etc. ,complete as per the direction of the Engineer-in-charge. a) Ground Floor
Finishing wall surface of walls with Acrylic wall putty of approved make and finished smooth and even surface to receive painting including cost of scaffolding & staging charges with,cost of all materials, taxes, cess, labour, conveyance, royalties, watering, curing, tools and plants, etc. complete, as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Providing and applying painting over the plastered surfaces with 2 coats of Plastic emulsion paint over a coat of Cement primer of approved quality and shade, using the required quantity of Plastic emulsion paint as specified by the manufacturer to give an even shade including cost of all materials, labour, conveyance, taxes, cess, royalties, scaffolding, watering, curing, sundries, tools and plants, etc., complete as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Supplying, Fitting & Fixing M.S. Grill, Grills gates, MS gates, garage door, collapsible gates with top and bottom rails, steel windows, critical frames for windows, stair case and parapet railing made out of MS Square bar / flat including stair case hand railing with 40mm dia GI pipe etc. including drilling holes in walls priming the grill with red oxide primer including cost ,conveyance, taxes of all material, labour ,cess required for the work complete as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Painting two coats with Synthetic enamel paint of approved quality and shade over a coat of primer (Red Oxide Primer) on surfaces as specified below Steel Surface) to give an even shade with 2 coats of approved quality paint, including cost of all materials, labour, conveyance, taxes, cess, royalties, scaffolding. watering, curing, sundries. tools and plants, etc., complete as per the direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Supplying, fitting and fixing of Stainless steel of 304 grade in hand railing using 50mm dia of 2mm thick circular pipe with Balustrade of size 32mm x 32mm x 2mm @ 0.90mtr. C/C and stainless square pipe bracing of size 32mm x 32mm x 2mm in 3 rows in stair case as per approved design and specification, buffing, polishing etc with cost, conveyance, taxes of all materials, cost of all labour,labour cess, T&P etc. required for the work complete in all respect as per specification & direction of the Engineer-in-charge. a) Ground Floor
b) 1st Floor
Finishing wall surface with painting two coats with Weather coat paint (1st quality) exterior grade over a coat of Cement Primer (Water based) of approved make & approved shade to make an even finished surface in all floors and heights with all scaffolding and staging charges including cost, conveyance, cess, taxes of all materials, cost of all labours, T & P, sundries etc. as required for the work complete in all respect as per the direction of the Engineer-in-Charge. a) Ground Floor
b) 1st Floor
c) 2nd Floor (Head Room)
Supplying, fitting and fixing vitrified tiles of premium grade having thickness 10mm confirming to IS 13755 of size 600mm x 600mm Plain (Ivory) series (homogenious) of approved make a shade (Orient Bell, Somany, Kajaria, Johnson) in floors on 20mm thick bed of C.M. (1:4) (Using Branded Cement) and filling the joint with white cement mixed with pigment to match the shades of the tile including washing and cleaning with oxalic acid complete including cost of all materials, taxes, labour, labour cess, T&P etc. required for the work complete in all respect as per specification & direction of Engineer-in-charge. a) 1st Floor
Providing, fitting, fixing vitrified tiles of premium grade having thickness 10mm confirming to IS 13756 of size 600mm x 600mm Plain (Ivory) series (homogenious) of approved make (Orient Bell, Somany, Kajaria, Johnson) in dados skirting and risers of steps on 12mm thick cement plaster (1:3) (Using Branded Cement) jointed with neat cement mixed with pigment to match the shades of the tiles including washing and cleaning with oxalic acid and polishing etc. complete with cost, conveyance, royalties and taxes of all materials all labour,labour cess complete in all respects as per specification & direction of Engineer-in-charge. a) 1st Floor
Providing (20cm x 30cm / 20cm x 20cm)size special plain/printed series Ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of approved make and shade in dado/skirting and rises of steps to any height in all floors, fixed with neat cement slurry, after soaking the tiles in water, over 12 mm thick cement mortar (1:3)(1 cement : 3 sand) (Using Branded Cement) mix, joint pointed with white cement mixed with matching pigment to match the shade of the tiles , including washing and cleaning with oxalic acid, including cost of all materials, conveyance, royalties, taxes, cess, labour, scaffolding, watering, curing, sundries, T&P etc. complete as per the direction of the Engineer-in-charge. a) 1st Floor
Providing and fixing 65mm X 125mm factory made single extruded WPC (Wood Polymer Composite) solid door/window/Ceosetory windows & other Frames/Chowkhat comprising of virgin PVC polymer of K value 58-60 (Suspension Grade), calcium carbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives (maximum toxicity index of 12 for 100 gms) fabricated with miter joints after applying PVC solvent cement and screwed with full body threaded star headed SS screws having minimum frame density of 750 kg/cum, screw withdrawal strength of 2200 N (Face) & 1100 N (Edge), minimum compressive strength of 58 N/mm2, modulus of elasticity 900 N/mm2 and resistance to spread of flame of Class A category with property of being termite/borer proof, water/moisture proof and fire retardant and fixed in position with M.S hold fast/lugs/SS dash fasteners of required dia and length complete as per direction of Engineer-In- Charge. (Make: WPC Door Frame: Century/Black Cobra/Rajshri Plastiwood,Colour:Coffee Brown) Note: For WPC solid door/window frames, minus 5mm tolerance in dimensions i.e depth and width of profile shall be acceptable. Variation in profile dimensions on plus side shall be acceptable but no extra payment on this account shall be made. a) 1st Floor
Supplying, fitting and fixing of 32mm thick flush door shutter with approved quality of 30mm thick BWR block board pasted with 1mm thick sunmica on both side of approved design and quality including cost of all door fitting and fixture complete etc including cost of all materials, hardware fittings, labour, conveyance, loading and unloading, taxes, cess, royalties, scaffolding, sundries, tools and plants etc. complete as per the direction of the Engineer-in-charge. a) 1st Floor
Supplying & fitting, fixing of Un-plasticised poly Vinyl Chloride (UPVC) (FENESTA/NCL VEKA LTD) Three track three panel sliding window-60-series duly Manufactured using UPVC reinforced profiles of 108mm x 45mm x 2.5mm for outer frames and window sash of 39mm x 58mm x 2.5mm capable of mounting single glazing system structurally reinforced with hot dip galvanised upto 50 microns of minimum thickness of 1.5mm prefabricated & welded through fusion welding the window frame shall be fitted with 6mm thick clear toughened glass of SAINT-GOBAIN make duly fixed with EPDM weathering seal resistant and the system is to be installed using Reinforced large coupler at the site using anchor fasteners, silicon rubber sealant, easy glazing / deglazing at site etc. including cost & conveyance of all materials acessories labour charges, Cess, taxes of all materials & product conforming to ASTM D 638-14 EN-477-95 and other applicable codes and standards. a) 1st Floor
Providing and supplying aluminium extruded tubular and other aluminium sections as per the architectural drawings and approved shop drawings , the aluminium quality as per grade 6063 T5 or T6 as per BS 1474,including super durable powder coating of 60-80 microns conforming to AAMA 2604 of required colour and shade as approved by the Engineer-in-Charge. (The item includes cost of material such as cleats, sleeves, screws etc. necessary for fabrication of extruded aluminium frame work. Nothing extra shall be paid on this account). a) 1st Floor
Designing, fabricating, testing, protection, installing and fixing in position semi (grid) unitized system of structural glazing (with open joints) for linear as well as curvilinear portions of the building for all heights and all levels, including:(a) Structural analysis & design and preparation of shop drawings for the specified design loads conforming to IS 875 part III (the system must passed the proof test at 1.5 times design wind pressure without any failure), including functional design of the aluminum sections for fixing glazing panels of various thicknesses, aluminium cleats, sleeves and splice plates etc. gaskets, screws, toggles, nuts, bolts, clamps etc., structural and weather silicone sealants, flashings, fire stop (barrier)-cum-smoke seals, microwave cured EPDM gaskets for water tightness, pressure equalisation & drainage and protection against fire hazard including: (b) Fabricating and supplying serrated M.S. hot dip galvanised / Aluminium alloy of 6005 T5 brackets of required sizes, sections and profiles etc. to accommodate 3 Dimentional movement for achieving perfect verticality and fixing structural glazing system rigidly to the RCC/ masonry/structural steel framework of building structure using stainless steel anchor fasteners/ bolts, nylon seperator to prevent bimetallic contacts with nuts and washers etc. of stainless steel grade 316, of the required capacity and in required numbers.(c) Providing and filling, two part pump filled, structural silicone sealant and one part weather silicone sealant compatible with the structural silicone sealant of required bite size in a clean and controlled factory / work shop environment, including double sided spacer tape, setting blocks and backer rod, all of approved grade, brand and manufacture, as per the approved sealant design, within and all around the perimeter for holding glass.(d) Providing and fixing in position flashings of solid aluminium sheet 1 mm thick and of sizes, shapes and profiles, as required as per the site conditions, to seal the gap between the building structure and all its interfaces with curtain glazing to make it watertight. (e) Making provision for drainage of moisture/ water that enters the curtain glazing system to make it watertight, by incorporating principles of pressure equalization, providing suitable gutter profiles at bottom (if required), making necessary holes of required sizes and of required numbers etc. complete. This item includes cost of all inputs of designing, labour for fabricating and installation of aluminium grid, installation of glazed units, T&P, scaffolding and other incidental charges including wastages etc., enabling temporary structures and services, cranes or cradles etc. as described above and as specified. The item includes the cost of getting all the structural and functional design including shop drawings checked by a structural designer, dully approved by Engineer-in-charge. The item also includes the cost of all mock ups at site, cost of all samples of the individual components for testing in an approved laboratory, field tests on the assembled working structural glazing as specified, cleaning and protection till the handing over of the building for occupation. In the end, the Contractor shall provide a water tight structural glazing having all the performance characteristics etc. all complete as required, as per the Architectural drawings, as per item description, as specified, as per the approved shop drawings and as directed by the Engineerin- Charge. Note:- 1. The cost of providing extruded aluminium frames, shadow boxes, extruded aluminium section capping for fixing in the grooves of the curtain glazing and vermin proof stainless steel wire mesh shall be paid for separately under relevant items under this sub- head. However, for the purpose of payment, only the actual area of structural glazing (including width of grooves) on the external face shall be measured in sqm. up to two decimal places. Note:-2. The following performance test are to be conducted on structural glazing system if area of structural glazing exceeds 2500 Sqm from the certified laboratories accreditated by NABL(National Accreditation Board forTesting and Calibration Laboratories), Department of Science & Technologies, India. Cost of testing is payable separately. The NIT approving authority will decide the necessity of testing on the basis of cost of the work, cost of the test and importance of the work. Performance Testing of Structural glazing system Tests to be conducted in the NABL accredited lab or by any other accreditation body which operates in accordance with ISO/ IEC 17011 and accredits labs as per ISO/ IEC 17025. a) 1st Floor
Providing openable side / top hung vision glass panels (IGUs) in structural glazing including providing and supplying at site all accessories and hardwares for the openable panels as specified and of the approved make such as heavy duty stainless steel friction hinges, min 4 -point cremone locking sets with stainless steel plates, handles, buffers etc. including necessary stainless steel screws/ fasteners, nuts, bolts, washers etc. all complete as per the Architectural drawings, as per the approved shop drawings, as specified and as directed by the Engineer- in-Charge. a) 1st Floor
Providing 2.5cm thick Grading Concrete over roof slab with cement concrete (1:2:2) (Using Branded Cement) using 4.7mm size hard granite crusher broken chips and screened & washed sharp sand and finished smooth to the rough surface of roof slab including watering and curing with cost, conveyance, royalties and taxes of all materials with cost of all labour, labour cess and T&P required for the work etc. complete in all respect as per specification & direction of Engineer-in-charge. a) 2nd Floor (Head Room)
Providing R.C.C M-20 grade (Using Branded Cement) with 20mm and down grade hard granite (crusher broken) aggregate and fine aggregate conforming to IS 383) in Drain as per approved drawing including dewatering, centering and shuttering, cost, conveyance, taxes, cess,royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge. a) Drain Bed & Cutof Wall
b) Drain Wall
c) Drain Slab
Clearing and grubbing road land including uprooting rank vegetation, grass, bushes, shrubs, saplings and trees girth upto 300mm, removal of stumps of trees cut earlier and disposal of unserviceable materials and stacking of serviceable materials to be used or auctioned upto a lead of 1000metres including removal and disposal of top organic soil not exceeding 150mm in thickness as per Clause 201 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost, conveyance, taxes, cess,royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.
Providing and laying Granular Sub-base with Grading-IV stone screening materials as per Table 400-1 and approved drawing as well as technical specifications complete in all respect as per Section 900 and Clause 401 of MoRT&H Specifications for Road & Bridge works (5th Revision) & including cost, conveyance, taxes, cess,royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge.
Supplying and fixing of 60mm thick cement concrete interlocking paver block of M-30 grade of approved make, design, colour and size made by Block making machine with proper compaction laid in required pattern etc. complete in all respect conforming to IRC SP-63:2018 and including cost, conveyance, taxes, cess, royalties of all materials, cost of all labour, T&P required for the work etc. complete as per specification & direction of Engineer-in-charge
P.H WORKS (PART-II) Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes conforming to IS:15778, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 20mm dia C - PVC pipe SDR - 11(First Floor)
25mm dia C - PVC pipe SDR - 11(First Floor)
32mm dia C - PVC pipe SDR - 11 top Floor
40mm dia C - PVC pipe SDR - 11 top Floor
Supplying all materials, labour T&P and fitting and fixing brass/CP fittings of the following nominal bore with supply of all joiniting materials including cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 15mm dia CP angle stop cock(FLR-ACR-5053N)
15mm dia CP two in one bib cock (Con-CHR-041KN Jaquar make)
15mm dia CP Long Body Bib cock (Con-CHR-107KN Jaquar make)
15mm dia CP Pillar cock (Con-CHR-011KN Jaquar make)
25mm dia brass full way valve (Shakti make)
32mm dia brass full way valve (Shakti make)
40mm dia brass full way valve (Shakti make)
15mm dia CP Health faucet (Con-ALD-MCH-573 Jaquar make)
gyser ELM-WHT-V006
WALL MIXER WITH PROVISION FOR OVERHEAD Shower (FLR-ABR-5273UPR)
15mm CP Extension piece
125mm CP grating
15mm size C.P. flange
Supplying all materials , labour, T&P and fixing rotational moulded polyethylene cylindrical vertical water storage tanks conforming to IS:12701/1996 including cutting holes through the tank and fixing mild steel tubes and fittings and providing extra sockets and jam nuts, fixing ball valve etc. including hoisting upto a height of 5 metres above ground level and placing the tank to the required position and providing 5.40 mtr. lengthx0.25 mtr width KB brickwork in cement mortar (1:6) of 0.46m height in staging and 0.13mtr thick circular protection wall of 0.46mtr height to support the tank,12mm thick cement plaster in cement mortar (1:6) over brick work, RCC slab of size 1.60mX1.60m and 0.10m thick ,RCC beam of 0.25mx0.30m and 3.40m average length in cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips and required steel reinforcement including centering and shuttering,watering,curing ,cost of all materials,conveyance of all materials to worksite , payment of royalty, all taxes etc.all complete as per approved drawing , P.H. specification and direction of Engineer-in-charge 2000 liters capacity PVC water storage tank roof of 1st floor
supplying all materials, labour, T&P and cutting holes through existing brick work including making good the damages in cement mortar (1:4) for taking G.I. Pipes and fittings/ P.V.C. pipes and fittings including watering, curing, cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per direction of Engineer-in-charge.(First Floor)
Supplying all materials , labour, T&P and cutting holes in RCC floors and roofs upto 19cm thick for passing P.V.C pipes and G.I fittings etc. , and repairing the holes after insertion of pipe etc. with cement concrete (1:2:4) including finishing complete so as to make it leak-proof as per P.H. specification and direction of Engineer-in-charge(First Floor)
Supplying all materials, labour, T&P and cutting grooves in pucca floors and walls for taking G.I./P.V.C. pipes and making good the damages including watering , curing , cost & conveyance of all materials to worksite, payment of royality, taxes etc all complete as per direction of the Engineer-in-charge.(First Floor)
Supplying all materials, labour, T&P and fitting and fixing U-PVC SWR soil waste ventilating pipes and fittings of the following outside diameter conforming to ISI No 13592/1992 to walls with nails, bobbins and wooden plugs or laying in trenches including jointing with supply of approved rubber lubricant by non-heat application method/as per manufacturer's specification, testing, earthwork in excavation in all kinds of soil and refilling of trenches , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 110mm U-PVC SWR Pipe (Supreme /Ashirvad)
110mm U-PVC ‘P’ Trap(Ori Plast/Finolex/Supreme Make)
110mm U-PVC door bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain bend(Ori Plast/Finolex/Supreme Make)
110mm U-PVC offset without ear(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Cowl(Ori Plast/Finolex/Supreme Make)
110mm U-PVC S/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Plain tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC D/Jn door(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Door tee(Ori Plast/Finolex/Supreme Make)
110mm U-PVC Socket(Ori Plast/Finolex/Supreme Make)
Supplying all materials, labour, T&P and fixing vitreous china water closet, squatting pan (Indian type W.C pan/Orissa pattern squatting pan) duly embedded in cement concrete (1:5:10) using 4cm size hard granite metal including fixing a pair of vitreous china 250mm x 130mm x30mm footrest, fixing 100mm dia HCI 'p' or 's' trap (with/without 50mm dia horn) for water colset squatting pan including jointing the trap with pan in cement mortar (1:1) cutting the floor and mending good the damages , cost & conveyance of all materials to worksite, payment of royality , taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge. 580mm size Orissa pan (Hindware/Parryware/Neycer make)
Supplying all materials, labour T&P and and fixing 12.50 liters/10 liters capacity low level flushing cistern with a pair of cast iron or M.S. brackets complete with fittings such as siphonic arrangements 15mm nominal size brass/pvc ball valve with polythene float CP brass handle,unions and couplings for connection with inlet, outlet and overflow pipes, 32mm dia CP long flush bend, 15mm dia pvc inlet connection pipe including cutting holes and making good the same and connecting the flush bend with cistern and closet and connceting the inlet pipe with suupply main , cost & conveyance of all materials to worksite, payment of taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge 10 ltr. Capacity pvc L.L. cistern with 32mm. Dia CP long flush bend ( Slimline-white-Parryware make )
Supplying all materials, labour, T&P and fixing the following vitreous china Wash Down Water Closet(European type W.C. pan)with integral 'p' or 's' trap to the floor with wooden plug and chromium plated pedestal screws including jointing the trap with soil pipe in cement mortar (1:1) fixing plastic seat and cover for wash down water closet with chromium plated brass hinges and rubber buffers including polishing , cost & conveyance of all materials to worksite, payment of royality, taxes etc. all complete as per P.H specification and direction of the Engineer-in-charge One piece commod(Hindware)ELEMENT Cat No.92084.
Supplying all materials, labour T&P and fixing wash basins with hole for pillar taps with cast iron or M.S.brackets painted white including cutting holes in walls and making good the damages with supply of wooden plugs, screws and cement etc, fixing pedestal for wash basin recessed at the back for the reception of pipes and fittings, fixing PVC waste pipe of 32mm nominal diameter for wash basin including brass check nut complete, fixing pillar taps capstan head screw down high pressure lettered 'Hot' and 'Cold' with long screws, shanks and back nuts of 15mm dia nominal bore, fixing 15mm dia PVC inlet connection pipe and making connection with pillar cocks and supply mains for wash basin, fixing 32mm dia CP brass waste, cost & conveyance of all materials to worksite, payment of taxes etc. all complete as perP.H specification and direction of the Engineer-in-charge Halfpedestal basin(560x450)Hindware No.91049+91115
Supplying all materials, labour, T&P for fitting & fixing plain edge kitchen/wall sink of all standard sizes with a pair of bracket, C.P. waste, trap & P.V.C. waste pipe & painting brackets including supply of cement concrete & mortar etc. all complete. 24” x 18” x 10” sink
Supplying all materials, labour, T&P and fixing standard sized CP towel rail complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge 25mmx600mm long CP towel rail
Towel ring
Supplying all materials, labour, T&P and fixing standard sized glass-shelf with CP brass brackets and guard rail complete fixed to wooden plugs with CP screws as per specification and direction of Engineer in charge. 600mmx125mm plate glass shelf with CP/NP guard rails.
Supplying all materials, labour, T&P and fixing mirror of superior glass mounted on 6mm.thick A.C. sheet or ply wood sheet and fixed to wooden plugs with CP screws and washers complete as per specification and direction of Engineer in charge. 600mmx450mm size B.E mirror (swivelled type)
Supplying all materials, labour, T&P and fixing CP soap holder complete with CP brass brackets fixed to wooden plugs with CP screws as per specification and direction of the Engineer in charge CP soap holder
Supplying all materials labor T&P & Fitting & fixing CP shower with rim with supply of red lead and yarn nail complete as per direction of Engineer in charge. ½” x 5” CP Shower (Plaza Deluxe Make)
Supplying all materials , labour, T&P and cutting holes through existing brick or laterite masonry wall for taking U-PVC pipes and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials , labour, T&P and cutting of RCC chajja for taking HCI or U-PVC pipe and fittings including making good the damages etc. all complete as per P.H. specification and direction of Engineer-in-charge
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
Supplying all materials ,labour ,T&P and constructing gully trap chamber of inside size 250mmx250mm with 8cm thick RCC precast cover slab in cement concrete (1:2:4) mix using 12mm size crusher broken HG chips, foundation concrete (1:4:8) using 40mm size crusher broken HG metal on bed and around trap, KB brick work in cement mortar (1:6) in foundation and plinth and inside 12mm thick cement plastering (1:3) finished with a floating coat of neat cement including fixing 100mmx100mm size HCI gully trap, 150mmX150mm size CI grating etc.all complete as per drawing, specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge (First Floor)
Supplying all materials, labour, T&P and providing and fixing ceramic tiles in floors, treads or steps and landing on 25mm thick bed of cement mortar (1:1) ( 1 cement : 1 sand ) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge ( ceramic floor tiles of premium grade having thickness 7mm to 8mm conforming to IS 13755 of size Kajaria/Somany/Johnson tile 60cmx60cm special printed series to be pre-approved by the Engineer-in-charge ) Kajaria/Somany/Johnson tile 60cmx60cm (First Floor)
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:4) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.(First Floor)
Supplying all materials, labour, T&P and providing and fixing porcelain glazed tiles in dado skirting on 12mm thick cement plaster (1:3) jointed with neat cement slurry mixed with pigment to match the shades of the tiles including watering, curing,cost of all materials, conveyance of all materials to work site , payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge( ceramic wall tiles of premium grade having thickness 6.5mm to 6.7mm conforming to IS 13753 of size Kajaria/Somany/Johnson tile 6cmx30cm special plain / printed series to be pre-approved by the Engineer-in-charge ) Kajaria/Somany/Johnson tile 6cmx30cm (First Floor)
Granite Tiles 10mm Thick (First Floor)
Factory made single leaf Solid WPC (Wood polymer) composite door shutter of 25mm thickcompacted with wood grain finish structural foam panel of 29mm thickness and a density of 20kg/cu.mtr shall be used as core material for fitting the metal fittings such as tower bolts, aldrops, handles etc shall be provided. A structural adhesive compatible with (EPS) foam shall be used for bending the core material, The material and process for manufacturing the door shutters shall conform to RV-TIFAC composites Design Centre's standards and specifications and the door shutters Conforming to relevant I.S.specification. The finish of door shutter will be plain colour white/ Ivory/ Beige/ Light grey/ Mahogany/ Teak wood or any other colour using high quality pigments. Three heavy whight mild steel butt hinges type-I(ISI marked) size 100mm are to be fitted on one side of shutter.
Factory made Solid WPC door frame of size 95mmx55mm fabricated .The door frame consist of four segments which are provided with plug-in-socket arrangement in-situ in the mould. The segments are plugged in and are joined together by means of screw. The WPC frame shall be provided with The material and process for manufacturing the door frames shall conform to Relavent I.S.specification. The finish of door frame will be plain colour white/ Ivory/ Beige/ Light grey/ Golden brown/Mahogany/ Teak wood/sand stone/Champagne/Pastel blue or any other colour using high quality pigments complete in all respect as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P & constructing mesonary drain of size 0.30mtr x 0.45mtr drains as per P.H. design & specification including lead of all materials to site.
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 100mm dia P.V.C. pipe
150mm dia P.V.C. pipe
Supplying all materials labor T&P and constructing MH chamber of sizes earth work in excavation in all kinds of soil CC(1:1:8) with black granite chips size 46mm brick work with K.B. brick having crossing strength not less than 75 Kg /CM2 to 90 Kg/CM2s in CM(1:6)12mm C.P(1:8) inside MH chamber over benching with cement slush pointing (1:3)outside the MH chamber providing painting MS or CI step iron RCC(roof of slab with CC(1:2:4)with black granite chips size 12mm bending binding tying the grills placing of the reinforcement providing RCC color of required size refilling the cavity around the MH chamber with excavated earth including channeling the bed of MH etc all complete as per PH specification. MH size 0.91m x 0.91 m with 0.45 m (18” dia RCC Cover )
Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
2 nos 50 users RCC septic tank Earth work in excavation of foundation in all kinds of soil within 50m initial lead and 1.5m initial lift including rough dressing & breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per direction of the Engineer-in-Charge.
Extra lifts of 1.50 mtr or part thereof over the initial lift of 1.5 mtr in all kinds of embankments and road works and ordinary earthwork in general.
Supplying all materials, labour, T&P and providing shoring and shuttering foundation trenches, pits etc with close wooden planks or sheets shuttering etc all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete (1:3:6) with 4cm size hard granite metal including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 6mm thick cement plaster (1:4) on RCC work including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement punning including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for R.C.C works including false work and dismantling them after casting including conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
R.C.C beams,columns,girder and bressmer etc.
Supplying all materials, labour, T&P and providing M.S reinforcement for R.C.C work including cutting, bending, binding, and tying the grills and placing in position including cost of binding wire 18 to 20 gauge, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:1.5:3) with 12mm size hard broken granite chips for R.C.C works including hoisting, laying, watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing cement concrete (1:2:4) with 12mm size hard broken granite chips including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing 12mm thick cement plaster (1:4) on brickwork including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and providing brick work with K.B bricks having crushing strength not less than 75kg/cm² with dimensional tolerance ± 8 percent in cement mortar (1:4) including watering, curing, conveyance of all materials to worksite, payment of royalty, taxes etc all complete as per specification and direction of the Engineer in charge
Supplying all materials, labour, T&P and making MS step iron in 20mm diameter MS steel bars and fixing into walls of man hole/septic tank duly embedded in cement concrete (1:3:6) complete as per specification and direction of the Engineer in charge.
Filling in foundation and plinth with excavated materials, moorum including watering and ramming as directed by the Engineer in charge
14,000 ltr capacity R.C.C. Under ground sump of in side size (2.80m x 2.80m x 2.0m) Earth work in All kinds of soil and gravels mixed with stone and boulder not exceeding 0.014 Cum in volume within 50m initiallead and 1.5 m initial lift including rough dressing and breaking clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth and as per specification approved by the Department.
-do- with Ist additional depth of 1.50 m over the initial lead and lift
Supplying all labor T&P & filling foundation and plinth with excavated materials well watered & rammed etc. all complete as per direction of EIC.
Supplying all materials, labour, T&P and filling in foundation and plinth with sand well watered and rammed including conveyance of all materials to worksite, payment of royalty, taxes etc.all complete as per direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing cement concrete ( 1:2:4 ) with 12mm size crusher broken hard black granite chips including watering, curing,cost of all materials, conveyance of all materials to work site with payment of royalty, all taxes etc all complete as per P.W.D specification and direction of Engineer-in-charge
Supplying all materials, labour, T&P and providing cement concrete (1:1½:3) with 12mm size crusher broken hard black granite chips for RCC works including hoisting, laying, watering, curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc. all complete as per PWD specification and direction of the Engineer in charge.
Supplying all materials, labour, T&P and providing steel reinforcement of Fe-415 /Fe-500 grade for RCC work including cutting,bending,binding and tying the grills and placing in position including cost of binding wire 18 to 20 gauge,cost of steel, conveyance of all materials to worksite, payment of royalty,all taxes etc all complete as per PWD specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing rigid and smooth centering and shuttering for RCC work including false work and dismantling then after casting including cost of materials complete in ground floor. RCC floor roof, chajja up to 4.430m height .
Supplying all materials,labour,T&P and providing 12mm thick cement plaster(1:3) on brick work including watering,curing,cost of all materials, conveyance of all materials to worksite,payment of royalty,all taxes etc.all complete as per PWD specification and direction of the Engineer-in-charge.
Supplying all materials, labour, T&P and providing cement punning including watering, curring and conveyance of all materials to site.
Construction of production well including scientific source finding through consolidated and unconsolidated rock with down the ODEX drilling rig with PVC, GI, MS pipe and installation of submersible pump set with all accessories. Labour for drilling a perfectly vertical bore hole of specified dia for a specified depth below ground level through consolidated and unconsolidated rock with combination drilling rig as required to suit the site condition as per the direction of Engineer-in-charge including supply of own rig with its accessories, tools and plant and consumables etc. for lowering of 200mm /150mm dia M.S. Pipe / PVC casing fitted with socket and with or without well screen as per the necessity for sub-medium hard and boulder formation (M.S./PVC casing pipe if required to prevent collapse of over burden is to be provided by contractor including lowering and withdrawing after completion of the tube well) 200mm dia x 400mm dia in over burden position inlcluding packing of gravel supplied by Contractor for 400mm bore only etc as per direction of Engineer incharge. Drilling for 200mm dia bore 00mtr to 20 mtr
21mtr to 65 mtr
Drilling for 150mm dia bore 65mtr to above
Lowering the following size of G.I. / PVC / M.S. housing pipe with or without slotted pipe as per the necessity for ground level upto 45 mtr depth and fitted and fixed up perfectly vertical position including cutting and threading of pipes and slotted pipes and supplying and fixing all jointing materials, tools and plants etc all complete and keeping the top of the casing pipe threaded including plugging tube wells to prevent entry of foreign materials. Lowering 200mm dia M.S.ERW pipe casing pipe 00mtr to 65 mtr
Cleaning and developing the tube well with supply of compressor worked till clear and adequate discharge in obtained from the tube well including supply and use of all necessary equipment and labour as per direction of Engineer-in-charge. By DTH / Rotary
Supplying all labour, materials and T&P for providing sanitary sealing by cement concrete grouting of annular space around M.S. casing pipe uptp 5 mtr below groun dlevel to plug the bore hole excluding cost of cement etc all complete as per direction of EIC.
Supplying all materials, labour, T&P and providing fittings and fixing submersible pump with squarrel cage induction type submersible electric motor to run on 3 phase / single phase line voltage ranging from 320 volt to 450 volt conforming to IS:8034/89 with following specification with suitable control panel, jointing with GI / PVC / HDPE pipes, electrification, testing commissioning, trial running, conveyance of all materials to worksite, payment to taxes etc all complete as per the specification and direction of the Engineer in charge. (Texmo / Crompton Greaves / Kirloskar make) 2HP single phase 3 stage vertical / horizontal submersible pump set at head range 20 to 35 meters discharge 145 to 110 LPM with outlet dia of 25mm
DOL control panel
40mm steel short piece
well cap
50mm size CI bracket
4 sqmm flat cable
steel rope with cover
labour charges for lowering including transportation
Supplying all materials, labour, T&P and providing and fixing to wall or ceiling and floor GI/PVC pipes, class-IV (10 k.g. F/cm) on firming I.S.4985 of the following nominal bore, tube fittings and clamps including making good the wall, ceiling and floor, testing all complete as per specification and direction of the Engineer in charge. 32mm dia PVC ASTM pipe (sch-80)
Rain Water Harvesting System Supplying all materials, labour, T&P and fitting and fixing U-PVC, SWR soil waste ventilating pipes and fitting of the following outside diameter conforming to 13592/1992 to walls with nails bobbins and wooden plugs or laying in trenches including with supply of approved rubber lubricant by non-heat application method as per manufactures specification testing earth work in excavation in all kinds of soil and refilling of trenches all complete as per specification and direction of the Engineer in charge. 110mm U-PVC SWR Pipe (Ashirvad/Supreme Make)
110mm U-PVC Plain bend (Ori Plast/Finolex/Supreme Make)
110mm U-PVC Socket (Ori Plast/Finolex/Supreme Make)
125mm CP grating
Supplying all materials, labour, T&P and laying in trenches (to level or slope) unplasticized P.V.C. pipe conforming to IS 4985/2000 of the following out side dia for class- 3 (0.60mpa ) including jointing with supply of approved solvent cement by non-heat application method/as per manufacture's specification, provoding and laying in trench cement concrete (1:4:8) with 40mm size hard granite metal in the type C-1 standard bedding surrounding or encasing including concrete for bedding and curing etc all complete as per P.H. specification and direction of the Engineer in charge 160mm dia P.V.C.
Supplying all materials labour T&P and constructing 1.80m dia x 2.60 m deep soak way pit with dry brick having crossing strength not less than 75Kg/CM2 to 99Kg/CM2 in CM(1:6) for the remaining 0.4572mm height of wall at top CC(1:3)inside and outside inside fill with dry brick khoa size 38mm ,CM thick RCC perforated slab to a height of 1.9012m from bottom covered by means of 50mmthick RCC wall cover in pieces filled with iron plugs including earth work in excavation refilling of cavity around the pit and painting the iron works complete as per PHD design and specification including carriage of all materials to site.
Supplying all materials ,labour ,T&P and constructing Inspection Chamber of inside size 760mmx760mmx460mm with cement concrete (1:3:6) using 40mm size crusher broken hard black granite metal on bed , KB brick work in cement mortar (1:6) in foundation and plinth, moulding and shaping the channel inside and benching with cement concrete (1:2:4) using 12mm size crusher broken hard black granite chips, 12mm thick cement plaster (1:3) with cement punning to inside, cement flush pointing (1:3) to outside, R.C.C cover slab (1:2:4) using 12mm size crusher broken hard black granite chips with R.C.C man hole cover, earth work in excavation in all kinds of soil and refilling the cavity around the chamber including watering,curing,cost of all materials, conveyance of all materials to worksite, payment of royalty,all taxes etc.all complete as per approved drawing, P.H specification and direction of Engineer-in-charge Inside size 76cmx76cmx46cm with 18” dia RCC MH cover
E.I. WORKS (PART-III) Recessed wirring to light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor of ISI marked Make- Finolex/Polycab/KEI with 20 mm dia HMS FRLS PVC conduit ISI marked Make-AKG/BEC/Precision/Anchor 6A modular type switch ISI marked Make-Schneider(Zencelo)/legrand( Myrius) /Siemens (Marq) and ceiling rose ISI marked of modular type G.I box with metallic cover plate (both side) Make-Schneider(Zencelo)/legrand( Myrius) /Siemens (Marq) of suitable size, modular box with 1.5 sq. Mm FRLS PVC insulated single core multistandard copper conductor as earth wire including all accessories and connection as per direction of Engineer -in -Charge. Group-A: L.P= F.P= C.B.P=
Group-B: L.P= F.P= C.B.P=
Group-C: L.P= F.P= C.B.P=
Supplying and fixing two module steeped type electronic fan regulator with proper modular plate switch box including connections etc. as required. Make: Legrand(Myirus)/schneider-Zenclo/Siemens (Marq)
Supplying,fixing of 6A Plug on the separate board with complete fitting by 01 no of 6A switch & socket(modular type)( ( flame retradant type)) with suitable size modular box & cover( flame retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge..Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision).
Supplying ,fixing of 6A Plug on the same board in existing switch board with complete fitting by 01 no of 6A switch & socket (modular type)( (flame retradant type)) & other required accessories of ISI marked as approved as per direction of Engg. -in -Charge. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision).
Supplying,fixing of 1x16A Plug on the separate board with complete fitting by 01 no of 16A switch & socket(modular type)with suitable size modular box & cover(anti bactorial & falme retradant type) including supplying of all required accessories of ISI marked as approved as per direction of engg-in-charge.. Make-Schneider(Zencelo)/legrand( Myrius) /Panasonic (vision)or equievalant reputed make A catagory ISI marked as approved. For Portable Loads Socket should be placed at 300-450mm above FFL. For Kitchen 200-300mm above platform.. For general 1200-1500mm above FFL.
Supplying, installation, testing & commissioning of 25 amp modular socket outlet on surface or in recess, on 1 Nos two module GI box with plate etc. complete as direction of Engineer-in-charge.Switch & socket: Legrand(Myirus)/schneider-Zenclo/Simens(Marq)
Wiring for circuit/ submain wiring along with earth wire of following size of FRLS heavy gauge PVC insulated copper conductor single core cable in heavy duty FRLS PVC conduit laid in surface/ recess as required.Wire KEI/Polycab/Finolex 2 x 1.5 sq.mm + 1 x 1.5 sq.mm in 20mm conduit
2 x 2.5 sq.mm + 1 x 1.5 sq.mm in 20mm conduit
2 x 4 sq.mm + 1 x 2.5 sq.mm in 20mm conduit
4 x 10 sq.mm + 2 x 6 sq.mm
Supplying and fixing of energy-efficient 18W LED square/round surface/recess mounted luminaire (die-cast aluminium housing, frosted diffuser, 1800 lumens, CRI ≥80, CCT 6000K, THD <10%, electronic driver with 3kV surge protection, L70B50 ≥50,000 hrs, 220–240V AC) with all accessories, complete. make: Panasonic/L&T/Havells/Philips/Wipro/Crompton/Bajaj.
Supply and fixing CALL bell (Ding dong type) /Buzzer on the existing switch box/cover.Make- Havells/Anchor.
SITC of energy efficient LED tube light fittings with decorative alluminium batten and LED tube light having power rating not more than 20 watt and lumen output not less than 2200 lumen complete with electronic driver and all other accessories.
Supplying, installation, testing and commssioning of 1200 mm sweep white/milky colour BLDC ceiling fan with aluminium blades having wattage not more than 28W and air delivery ≥215m3/min Make-Crompton Energion Groove /Havells Efficiencia Neo/Usha Technix ) including wiring the down rod of standard length (upto 30 cm) with 1.5 sq mm PVC insulated, copper conductor, single core cable etc.
Supplying of Exhaust fan / fresh air fan with louvre (Make -Crompton/ Orient/ Havells/Polycab) as required. 200 mm sweep iron body fresh air fan
Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
4 Way(8+12+12) Way TPN MCB DD 7 Segment DB Horizontal Type as per IEC 61439-3 with configuration of incomming I-8 modules,sub incommer-12 module & out going-12 modules,suitable for Flush mounting and Surface mounting with Copper Bus Bar for each phase, with neutral Bus bar, Earth Bar & Cable ties for cable management, prefitted masking sheet, IP43-IK09 with metal door.
Supplying and fixing following rating RCBOs/ MCBs in the existing DB complete with connections,testing and commissioning etc. as required . Make :- Legrand/ABB/LK 63 Amps4P RCCB ( 30mA 2 nos, 100mA 1 No)
63 Amps 4P MCB .make-Legrand/DX3/siemens-Betaguard/Schneider-acti9/ABB FB 200 or equivalent
6A/32A SPMCBs(C-Curve) . make-Legrand/DX3/siemens-Betaguard/Schneider-acti9/ABB FB 200 or equivalent
Installation, testing and commissioning of exhaust fan up to 200 mm sweep in the existing opening, including making the hole to suit the size of the above fan, making good the damage complete, connection, etc as required.
Supplying,installation,testing & commissioning of materials and installation of Copper earth plate 600mmx600mmx3.15mm thick ISI marked with G. I. nut bolts & washers including cost of burnt wood charcoal, salt, foreign soil, water pouring arrangements, brick masonary enclosure on top with removable RCC cover complete with labour for excavation of pit in all kinds of soil & rock as required and as per direction of Engineer-in-charge.The entire earthing system should be Replacement Warranty will be 2 years
Supply and Fixing of 90 watt LED street light.Make-Panasonic/L&T /Havells/Phillips/Wipro or Equivalent.
Supplying and installation of 25A AC starter Modular type, Schneider/Siemens/Legrand coil voltage-230 Volt A.C.on mod Box of suitable size including modular coveras required as per direction of Engg.-in-Charge .
Providing, fabricating, supplying, installing, testing and commissioning of wall-mounted LT metering panel made of CRCA sheet steel, powder coated, dust and vermin proof, suitable to accommodate 5 Nos. single-phase energy meters, complete with meter mounting arrangement, incoming and outgoing cable termination, neutral links, common earth bar, cable glands, internal wiring and all accessories, complete in all respects, excluding energy meters, as per CPWD specifications and directions of the Engineer-in-Charge.
SITC of EES Conventional Aluminium lps type Lightning Arrester with complete accessories.
Please Enable Macros to View BoQ information
stage.html
html • 0.12 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.81 MB
DTCN_4NosDTypeQtr_Sub-DivisionSundargarh.pdf
Tender Documents • 2.72 MB
BOQ_584378.xls
BOQ • 1.24 MB
Download all tender documents and submit your bid