Tender Value
Refer Docs
EMD Value
₹3.1 Cr
Closing Date
3 Aug 2023, 5:30 pmClosed
Group General Manager (Civil Contracts-III)
Room No.214, 2nd Floor, Jyoti Sadan, NHPC OFFICE COMPLEX, Sector-33, Faridabad-121003, Haryana, India Tele No 91 129 2250848 Email contcivil3-co at rate nhpc.nic.in
EPC contract for development of 50 MW Floating Solar Power Project and associated transmission system for Grid Connectivity along with Comprehensive O and M for 05 (Five) years at West Kallada District-Kollam, in the state of Kerala
2023_NHPC_748125_1
NH/CCW/CC-III/CO 242/PR10022/462
Open Tender
Power/Energy Projects/Products
456 days
West Kallada District-Kollam
As per Tender Document
10 documents required · 10 mandatory
₹10,000
Yes
GM NHPC
₹3.1 Cr
Yes
NHPC OFFICE COMPLEX ,FARIDABAD
15 Sept 2023
5 Apr 2023
10 Aug 2023
5 Apr 2023
3 Aug 2023
25 May 2023
5 Apr 2023 - 18 Apr 2023
20 Apr 2023
Amount
SPV MODULES AND ACCESSORIES: SPV modules complete with all accessories, Mandatory/Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
MODULE CLEANING ARRANGMENT: Module Cleaning Arrangement complete with all accessories, Mandatory/Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
MODULE MOUNTING STRUCTURES (If applicable): Module mounting structures complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FLOATATION DEVICE : Floatation device (Main Float for suporting PV Modules, Secondary Float between rows for maintenance etc) complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ANCHORING AND MOORING SYSTEM: Anchoring and Mooring system complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
POWER CONDITIONING UNITS: Power Conditioning Units/ Inverters complete with all accessories, Mandatory/Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
CABLING SYSTEM: Cabling System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
METEOROLOGICAL MEASURING INSTRUMENTS: Meteorological Measuring Instruments complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
STRING COMBINER BOX: String Combiner Box complete with all accessories, Mandatory/ Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
SOLAR PLANT TRANSFORMERS (INVERTER DUTY TRANSFORMER) AND STATION SUPPLY TRANSFORMER/ AUXILIARY TRANSFORMER (Except Switchyard & Main Pooling Switchgear area) : Solar Plant Transformers & Station Supply transformer(s)/ Auxilliary Transformer complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
DC SYSTEM: DC System complete with all accessories, Mandatory/ Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
CONTROL AND MONITORING (SCADA) SYSTEM: Control & monitoring System including SCADA & Surveillace System ( For Solar Plant ) complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
PROTECTION SYSTEM: Protection System complete with all accessories , Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
33 kV (MV) SWITCHGEAR: MV System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
LT SWITCHGEAR: LT switchgear system complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ILLUMINATION SYSTEM: Illumination System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
GROUNDING SYSTEM: Grounding System complete with all accessories, Mandatory / Specified spares, Tools and Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FIRE PROTECTION & FIRE FIGHTING SYSTEM: Fire Protection & Fire fighting System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
Description of Work / Item(s)
Amount
SPV MODULES AND ACCESSORIES: SPV modules complete with all accessories, Mandatory/Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
MODULE CLEANING ARRANGMENT: Module Cleaning Arrangement complete with all accessories, Mandatory/Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
MODULE MOUNTING STRUCTURES (If applicable) : Module mounting structures complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FLOATATION DEVICE : Floatation device (Main Float for suporting PV Modules & Secondary Float between rows for maintenance etc ) complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ANCHORING AND MOORING SYSTEM: Anchoring and Mooring system complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
POWER CONDITIONING UNITS: Power Conditioning Units/ Inverters complete with all accessories, Mandatory/Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
CABLING SYSTEM: Cabling System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
METEOROLOGICAL MEASURING INSTRUMENTS: Meteorological Measuring Instruments complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
STRING COMBINER BOX: String Combiner Box complete with all accessories, Mandatory/ Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
SOLAR PLANT TRANSFORMERS (INVERTER DUTY TRANSFORMER) AND STATION SUPPLY TRANSFORMER/AUXILIARY TRANSFORMER (Except Switchyard & Main Pooling Switchgear area) : Solar Plant Transformers & Station Supply transformer(s)/ Auxilliary Transformer complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
DC SYSTEM: DC System complete with all accessories, Mandatory/ Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
CONTROL AND MONITORING (SCADA) SYSTEM: Control & monitoring System including SCADA & Surveillace System ( For Solar Plant ) complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
PROTECTION SYSTEM: Protection System complete with all accessories , Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
33 kV (MV) SWITCHGEAR: MV System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
LT SWITCHGEAR: LT switchgear system complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ILLUMINATION SYSTEM: Illumination System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
GROUNDING SYSTEM: Grounding System complete with all accessories, Mandatory / Specified spares, Tools and Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FIRE PROTECTION & FIRE FIGHTING SYSTEM: Fire Protection & Fire fighting System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works Including statutory approvals, permits, licenses,Testing, Calibration etc. for the Plant.
CIVIL & ALLIED WORKS
Main Control Rooms & Switchgear rooms
Fencing of Inverter Duty Transfomer & Auxilliary Transformer yard including Gates
Laying of Earthing System For Solar Plant Area
Foundation of Inverter Duty Transfomer and Auxilliary Transformer
Inverter Rooms
Module Cleaning Arrangement
Floating Device and Anchoring & Mooring System
Description of Work / Item(s)
Amount
COMPREHENSIVE OPERATION & MAINTENANCE INCLUDING ALL STATUTORY APPROVAL, PERMITS, LICENSE, TESTING, CALIBRATION ETC IN RESPECT OF ALL THE EQUIPMENT SUPPLIED UNDER THE ‘FIRST PRICE SCHEDULE' AND ANY OTHER SERVICES SPECIFIED IN THE CONTRACT DOCUMENTS (SECOND PRICE SCHEDULE) FOR FIVE YEARS FROM COMMISSIONING OF THE PLANT.
Description of Work / Item(s)
Amount
MAIN POOLING SUBSTATION : Main Pooling Substation equipment complete with all accessories, Mandatory / Specified spares , Tools & Instruments as per specifications and scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
OUT DOOR SWITCHYARD : Outdoor switchyard equipment complete with all accessories, Mandatory / Specified spares , Tools & Instruments as per specifications and scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
OFC, OPGW, PLCC INCLUDING ALL EQUIPMENTS FOR TELEMETRY: OFC/OPGW/PLCC etc complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
VOICE COMMUNICATION FACILITIES: Communication network,WLL/ Cell Phone/Landline etc complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
TARIFF ENERGY METER : Tariff Energy Meter for Metering with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
LT SWITCHGEAR: LT switchgear in Main Pooling & Switchyard Area complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
STATION SUPPLY TRANSFORMER/AUXILIARY TRANSFORMER (For Switchyard & Main Pooling Switchgear area) : Station Supply transformer(s)/ Auxilliary Transformer complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
POWER TRANSFORMERS: Power Transformers with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
EVACUATION SYSTEM: Evacuation equipmentwith all accessories ,Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
PROTECTION SYSTEM: Protection System For Main Pooling Substation, Switchyard and Transmission Line complete with all accessories , Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
CONTROL AND MONITORING (SCADA) SYSTEM & SUBSTATION AUTOMATION SYSTEM (SAS) complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
METEOROLOGICAL MEASURING INSTRUMENTS: Meteorological Measuring Instruments complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
DC SYSTEM: DC System for Main Pooling Substation, Outdoor Switchyard area complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
SURVEILLANCE SYSTEM: Surveillance System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ILLUMINATION SYSTEM : Illumination System for all approach Roads , Park Boundary, Switchyard & Main Pooling Substation area, all building inside Switchyard area, Guard Room, Ware Houses etc with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
GROUNDING SYSTEM: Grounding System For Switchyard, Main Pooling Substation, illumination System complete with all accessories, Mandatory / Specified spares, Tools and Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FIRE PROTECTION & FIRE FIGHTING SYSTEM: Fire Protection & Fire fighting System in Switchyard, Main Pooling Substation, all buidings inside Switchyard area including Nitrogen Fire Protection for Power Transformer complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
CABLING SYSTEM: LT, MV, EHV , COMMUNICATION, CONTROL & INSTRUMENTATION CABLING SYSTEM For Main Pooling Substation,Outdoor Switchyard Area, all buidings inside Switchyard area with all accessories, Mandatory / Specified spares , Tools & Instruments as per specifications and scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FLOATATION DEVICE: Floatation device for approach walkways (Between Land to solar plant floating block), Peripheral (Boundary) Corridor, Cable laying arrangement from Plant area to Main Pooling Substation complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ANCHORING AND MOORING SYSTEM: Anchoring and Mooring system with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
Description of Work / Item(s)
Amount
MAIN POOLING SUBSTATION : Main Pooling Substation equipment complete with all accessories, Mandatory / Specified spares , Tools & Instruments as per specifications and scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
OUT DOOR SWITCHYARD : Outdoor switchyard equipment complete with all accessories, Mandatory / Specified spares , Tools & Instruments as per specifications and scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
OFC, OPGW, PLCC INCLUDING ALL EQUIPMENTS FOR TELEMETRY: OFC/OPGW/PLCC etc complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
VOICE COMMUNICATION FACILITIES: Communication network,WLL/ Cell Phone/Landline etc complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
TARIFF ENERGY METER : Tariff Energy Meter for Metering with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
415 V (LT) SWITCHGEAR: LT switchgear in Main Pooling & Switchyard Area complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
STATION SUPPLY TRANSFORMER/AUXILIARY TRANSFORMER (For Switchyard & Main Pooling Switchgear area) : Station Supply transformer(s)/ Auxilliary Transformer complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
POWER TRANSFORMERS: Power Transformers with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
EVACUATION SYSTEM: Evacuation equipmentwith complete all accessories ,Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works Including statutory approvals, permits, licenses,Testing, Calibration etc. for the Park Facilities/ Infrastucture.
PROTECTION SYSTEM: Protection System For Main Pooling Substation, Switchyard and Transmission Line complete with all accessories , Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
CONTROL AND MONITORING (SCADA) SYSTEM & SUBSTATION AUTOMATION SYSTEM (SAS) complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
METEOROLOGICAL MEASURING INSTRUMENTS: Meteorological Measuring Instruments complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
DC SYSTEM: DC System for Main Pooling Substation, Outdoor Switchyard area complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works.
SURVEILLANCE SYSTEM: Surveillance System complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ILLUMINATION SYSTEM : Illumination System for all approach Roads , Park Boundary, Switchyard & Main Pooling Substation area, all building inside Switchyard area, Guard Room, Ware Houses etc with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
GROUNDING SYSTEM: Grounding System For Switchyard, Main Pooling Substation, illumination System complete with all accessories, Mandatory / Specified spares, Tools and Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FIRE PROTECTION & FIRE FIGHTING SYSTEM: Fire Protection & Fire fighting System in Switchyard, Main Pooling Substation, all buidings inside Switchyard area including Nitrogen Fire Protection for Power Transformer complete with all accessories, Mandatory / Specified spares, Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
CABLING SYSTEM: LT, MV, EHV , COMMUNICATION, CONTROL & INSTRUMENTATION CABLING SYSTEM For Main Pooling Substation,Outdoor Switchyard Area, all buidings inside Switchyard area with all accessories, Mandatory / Specified spares , Tools & Instruments as per specifications and scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
FLOATATION DEVICE: Floatation device for approach walkways (Between Land to solar plant floating block), Peripheral (Boundary) Corridor, Cable laying arrangement from Plant area to Main Pooling Substation complete with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
ANCHORING AND MOORING SYSTEM: Anchoring and Mooring system with all accessories, Mandatory / Specified spares and Tools & Instruments as per specifications & scope mentioned in Employer’s Requirements (Technical Specifications) for E&M Works
CIVIL & ALLIED WORKS
Geo-Technical, Hydrological, Topographical, Bathymetry Investigation/Survey etc Investigations and Testing
Land Developement
Green Belt Developement
Approach Roads from Main gate to Switchyard, Control room, Main Pooling Substation etc.
Peripheral Boundary of Control room, Switchyard etc.
Security Cabin/ Guard Room
Gates
Main Control Room & Switch Gear room
Fencing of Switchyard, Transformer yard including Gates
Laying of Earthing System of Project area Switchyard, Main Pooling Substation and other area of Solar park
Drainage System
Foundation of Switchyard Equipment,Main Pooling Substation, Transformer, Gantry Structure,transmission line tower etc.
Cable Trench in Main Pooling Substation & Switchyard Area
Water Supply System (Borewell, Storage, piping etc)
Construction of Septic Tank
Parking Shed and Ware Houses
Description of Work / Item(s)
Amount
COMPREHENSIVE OPERATION & MAINTENANCE INCLUDING ALL STATUTORY APPROVAL, PERMITS, LICENSE, TESTING, CALIBRATION ETC IN RESPECT OF ALL THE EQUIPMENT SUPPLIED UNDER THE ‘PRICE SCHEDULE FOURTH' AND ANY OTHER SERVICES SPECIFIED IN THE CONTRACT DOCUMENTS (FIFTH PRICE SCHEDULE) FOR FIVE YEARS FROM COMMISSIONING OF THE SOLAR PARK.
Description of Work / Item(s)
Total of Schedule 1:
Total of Schedule 2:
Total of Schedule 3:
Total of Schedule 4:
Total of Schedule 5:
Total of Schedule 6:
Description of Work / Item(s)
Amount
TOTAL GENERATION IN UNITS
Description of Work / Item(s)
TOTAL OF SCHEDULE NO. : 7 (GRAND SUMMARY) in INR
TOTAL GENERATION IN UNITS AS PER PRICE SCHEDULE : 8
BID PRICE PER UNITS OF GENERATION (INR/kWh)(For First Year in kWh)