Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.3 LAdmitted-Finance | ₹5.3 L | L1 | Admitted-Finance |
| 2 | L2₹5.6 LAdmitted-Finance GURU RAM DAS NAGAR SRI SAI VIHAR COLONY ALIGARH ALIGARH ALIGARH UTTAR PRADESH 202001 UDYAM UP 02 0016033 | ALIGARH | UTTAR PRADESH | 202001 | ₹5.6 L | L2 | Admitted-Finance |
| 3 | L3₹5.7 LAdmitted-Finance | ₹5.7 L | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | ELECTRO POWER SERVICES AND SOLUTIONS L3 | exSel Corporation L1 | AR Electricals & Hardware L2 |
|---|---|---|---|---|---|---|
| 1.00 | Rectification and revamp of existing SCADA System withSLD Configuration work, troubleshooting &rectification of existing bayfor digital and analogue data,breaker/Isolator status, alarm,and event at 220kV S/s Nighasan, UPPTCL under ETD Lakhimpur.The following works need to carried out for healthy SCADA communication.
- Modification of SLD as per latest configuration of S/s
- Rectification of metering data for all 220kV, 132kV and 33kV bays
- Rectification of Breaker and Isolator status of 220kV & 132kV bays, however, UPPTCL ensure all breakers and isolators mechanism/operation should be work smoothly.
- Breaker Open/Close status modification in existing SCADA
- Checking of all required events, alarms, numerical dataand signals to SCADA from various bays & feeders | 1 | Set | 1,90,000 ₹1,90,000 | 1,80,000 ₹1,80,000 Lowest | 1,88,000 ₹1,88,000 |
| 2.00New Bay Integration Works: | ||||||
| 3.00 | Complete configuration and testing of 220/132kV TransformerPanel Bay and its integration in existing SCADA System
- HV Side and
- LV Side both) | 2 | Job | 1,30,000 ₹2,60,000 | 1,25,000 ₹2,50,000 Lowest | 1,28,000 ₹2,56,000 |
| 4.00 | Mapping/Configuration of ICD/CID files for new transformer bays for LV and HV Side as per the scheme for fieldsignals includes IEC-61850 base BCUs/relayvariables, dataset configuration, report control block etc. for gateway and SCADA. | 2 | Job | 13,000 ₹26,000 | 12,500 ₹25,000 Lowest | 13,500 ₹27,000 |
| 5.00 | Configuration of new bay in existing gateway to transfer data at SLDC and ALDC. | 2 | Job | 28,000 ₹56,000 | 24,000 ₹48,000 Lowest | 28,500 ₹57,000 |
| 6.00 | Armored FO Patch Cord (LC-LC) 15 Meters (2 Nos.)
Armored FO Patch Cord (LC-LC) 5 Meters (2 Nos.)
Armored FO Patch Cord (LC-LC) 3 Meters (2 Nos.)
Cat6 Cable 15 Meter (2 Nos.)
Cat6 Cable 3 Meter (4 Nos.) | 1 | Set | 35,000 ₹35,000 | 23,000 ₹23,000 Lowest | 30,000 ₹30,000 |
Tender Value
Refer Docs
EMD Value
₹7,000
Closing Date
4 Jun 2026, 6:00 pmClosed
SE ETC Shahjahanpur
Electy Trans Circle Shahjahanpur
Work
2026_UPTCL_1118141_2
81 ETC(S)/2025-26
Open Tender
Electrical Works
Fixed-rate
60 days
Lakhimpur
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
A/c No. 0423002100107147 IFSC Code No. PUNB0042300
₹7,000
10 Aug 2026
30 May 2026
5 Jun 2026
30 May 2026
4 Jun 2026
30 May 2026
30 May 2026 - 4 Jun 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Rectification and revamp of existing SCADA System withSLD Configuration work, troubleshooting &rectification of existing bayfor digital and analogue data,breaker/Isolator status, alarm,and event at 220kV S/s Nighasan, UPPTCL under ETD Lakhimpur.The following works need to carried out for healthy SCADA communication.
- Modification of SLD as per latest configuration of S/s
- Rectification of metering data for all 220kV, 132kV and 33kV bays
- Rectification of Breaker and Isolator status of 220kV & 132kV bays, however, UPPTCL ensure all breakers and isolators mechanism/operation should be work smoothly.
- Breaker Open/Close status modification in existing SCADA
- Checking of all required events, alarms, numerical dataand signals to SCADA from various bays & feeders | 1 | Set | - | - |
| 2 | New Bay Integration Works: | - | - | - | - |
| 3 | Complete configuration and testing of 220/132kV TransformerPanel Bay and its integration in existing SCADA System
- HV Side and
- LV Side both) | 2 | Job | - | - |
| 4 | Mapping/Configuration of ICD/CID files for new transformer bays for LV and HV Side as per the scheme for fieldsignals includes IEC-61850 base BCUs/relayvariables, dataset configuration, report control block etc. for gateway and SCADA. | 2 | Job | - | - |
| 5 | Configuration of new bay in existing gateway to transfer data at SLDC and ALDC. | 2 | Job | - | - |
| 6 | Armored FO Patch Cord (LC-LC) 15 Meters (2 Nos.)
Armored FO Patch Cord (LC-LC) 5 Meters (2 Nos.)
Armored FO Patch Cord (LC-LC) 3 Meters (2 Nos.)
Cat6 Cable 15 Meter (2 Nos.)
Cat6 Cable 3 Meter (4 Nos.) | 1 | Set | - | - |
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.16 MB
BOQ_2165082.xls
BOQ • 0.27 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at [email protected].