Provision of CCTV surveillance system in c/w Upgradation of Parcel offices at 10 Stations (Patiala, Dhuri, Abohar, Ropar, Nangaldam, Una Himachal, Kalka, Ambala Cantt, Yamunangar Jagadhari, Saharanpur over Ambala Division.)
OT-20-2026-27
OT-20-2026-27
Open
180 Days
Saharanpur, Uttar Pradesh
₹0
₹89,900
3 Jul 2026
3 Jul 2026
10 Jul 2026
Supply of Full HD Bullet/Dome Type IPColour camera as perSpec. No:RDSO/SPN/TC/65/2021Ver.6.0 or latest.Inspection : RDSO
Supply of Surveillance HDD (8 TB surveillance Hard Disk Make : Toshiba, Seagate or similar .Inspection by RDSO
Supply of power cable 3 core, 2.5 sq mm, multi strend (36/0.3mm dia) cable as per IS 694:1990 or latest suitable for RE area, shall be make like Havells, Delton, LAPP, Finolex or superior as per RDSO spec. No. RDSO/SPN/TC/61/2015, Rev. 4.0 or latest. Inspection By-Consignee.
Supply UTP Cat -6 Patch Cord 3 Ft. long Schneider, Systemax, Panduit, D-Link, Molex with suitable connector at both ends Inspection by Consignee
Supply of Large Format LED Display Unit, 55" (inches) Including wall mount kit.as per clause 9.0 of RDSO/SPN /TC /65/2021 Ver. 6 with Amdt. 1 or latest. Inspection by RDSO
Supply of 6 Fiber Core armored single mode optic Fiber cable 17.2.2 of RDSO/SPN/ TC/65/2021 Rev.6.0 or latest Schneider, Systemax, Panduit, D-Link, Finolex Inspection by Consignee
Supply of HDPE duct 40/33 mm as per RDSO/SPN/TC/45/2013 Rev.2.0 with latest amendments as available. For each KM of HDPE DUCT following items are to be supplied a) End plugs-2no b) Cable sealing plugs-2 no. © Plastic couples slip fit/push fit b type-2 no d) End plugs to be provided along with drum-2 No.Inspection By-Consignee
Supply of STP (Shielded Twisted Pair) CAT-6 cable compliant with latest EIA/TIA-568- B. 2-1 standard of make D-Link/ DAX/Lucent/ Crone/Amp. Inspection by Consignee
Supply of Cat-6 I O BOX Make Schneider, Systemax, Panduit, D-Link, Molex, Inspection by Consignee
Supply of fiber optic patching cord (05 mtrs length) FC-FC/FC-PC/FC-SC/LC-SC/LC-LC as per site requirement/Site Engineer. Inspection by Consignee. Above/
Supply & installation of 19" 9U rack wall/pole mount with front door glass door type, 1 all doors sould be removable type with all accessories like two exhaust fans one AC Multiple(6 No.of 6 Amp socket), earthing strip copper etc.Make APW President or Rittal or HCL or Comrack or Schneider make as per instructions of Railway Engineer's Representative at site Inspection By- Consignee
Supply installation & fixing of 25 mm dia PVC conduit medium class pipe with all 2 accessories on any type of surface inluding wal with proper clamping etc. PVC conduit pipe shall confirm IS9537 (PtIII) as per Technical specifications given in Annexure 'E' & instructions of Railway Engineer'srepresentative at site Make Pipe D Plast, Polypack, Polycab Inspection by Site Engineer
Supply installation/recessing of 25 mm dia PVC conduit medium class pipe with all accessories junction box etc making chaise replastered PVC conduit pipe shall confirm IS9537 (PtIII) as per instructions of Railway Engineer at site Inspection by Site Engineer.
Supply, testing and commissioning of 1 KVA UPS with 1 hour backup. Make APC or similar of reputed make. Inspection by Consignee
Supply & configuration of 8 No. ports of 10/100/1000 Base-T PoE switch with 2 No.SFP 5 port 120W PoE Budget with supply of 2 No. Of 1G SFP Single mode optical transceiever modules as per clause no.14 (III) of RDSO Specs. No.RDSO/SPN/TC/65/ 2021 Ver.6.0 with Latest amendments and versions Make CISCO, JUNIPER,Zyxel, D-Link. Payment shall be done as per Tender document Inspection by Consignee
Boring & Trenchless cabling along with supply and insertion of HDPE pipe of PE 80 PN 6 8 grade of 90mm dia with min. 6.7mm and max. 7.6mm wall thickness as per IS 4984:2016 in the bore for the laying of signalling/ Telecom/Power cables under the track/ road.( cable lying is covered separately). HDPE pipe is to be supplied by the contractor. Inspection of Pipe by Consignee Work by Site Engineer
Supply and installation (Splicing of fiber) of rack mount LIU 12 core loaded with SC 7 adaptors. Including all accessories as per instructions of Railway Engineer's Representative at site. (pigtails and other miscellaneous material required for the work shall be supplied by the contractor. Make: D-Link, PANDUIT, systemax, Digilink,3M, Molex, Legrand, Commscope, Molex, 3C3, Amphenol FCI or similar of reputed make.Inspection by Consignee
Supply, installation & commissioning of basic earthing kit as per RDSO specification 8 no. RDSO/SPN/197/2008 or latest Earthing kit consisting of 1) Earth electrode of 17 mm dia and 3 M long -01 no. 2). MEEB (300X25X6) cu.mm-01 no. 3). SEEB (150X25X6) cu.mm -01 no. 4). Earth enhancing compound - 30 kg. This includes provision of earth connection from MEEB to S&T equipment i.e. cable sheath etc. with PVC multistrand wire of size 16/25 sq.mm through copper lugs of suitable size. PVC wire shall be supplied be by Railway & as per instructions given by Railway Engineer's Representative at site. Note:- At certain locations, it may not be possible to achieve earth resistance of less than or equal to 1 ohm with one earth electrode/pit due to higher soil resistivity. in such cases, provision of loop earth consisting of more than one earth pit shall be done. for inter connection of two earth pits copper tape of size 25 X2 sq.mm shall be provided by the Contractor. The number of pits required shall be decided based on the resistance achieved for the earth pit already installed. The procedure mentioned above for one earth pit shall be repeated for other earth pits. The other earth so installed for the purpose of loop earthing arrangement shall be counted as separate earth. Inspection:Consignee
Supply, installation, testing & commissioning of LAN Extender as per Specification No. RDSO/SPN/TC/82/2013 Rev.1.0 or latest & as per instructions given by Railway Engineer's Representative at site Inspection by Consignee.
Supply, Installation, Testing and Commissioning of RJ-45 Jack panel suitable for STP Cat-6 cable Make D-Link, AMP,DAX,Legrand, Molex or Digilink Inspection by Consignee Above/
Installation ,Testing and Commissioning of Full HD Bullet Type IP Colour camera along with the mount. All the accessories and fixing materials including mount required for this installation are tobe supplied by contractor within the same cost. Inspection : Site Engineer
Commissioning ,testing of IP network camera, VLAN and commissioning of the surveillance system of cameras with NVR and installing the storage devices and final testing of the entire system. Inspection:Consignee.
Laying of Data cable/Communication cable/ Power cable etc. in PVC conduit pipe/ PVC casing caping with all fittings and accessories as per instructions of consignee.Inspection by Site Engineer
Installation, testing and commissioning of large format display monitor unit 55" with 4 all accessories and fixing materials required for this installation are to be supplied by contractor within the same cost as perRDSO Specification No.RDSO/SPN/ TC/65/2021, Ver. 6 with Amdt. 1 Inspection by Site Engineer.
Excavating and refilling of trench in Normal Soil to the level of ground with rammed earth as per drg. No.(NR/S&T/CON /1.1/97-A) so as not to form a drain 0.3 Mtr. Wide & 1Mtr. Deep on 5 both side of the station alongside the track. It shall conform to the safe distance as per signalling and cable route plan in all type of soil, It also includes clearance of routes of trees & bushes. Lesser depth due to site condition shall be paid proportionately only after taking permission from atleast JAG officer Inspection by Site Engineer.
Laying of HDPE duct as per approved cable route plan in the exavated trenches/other protected work/RCC channel etc. including all accessories like end caps, collars, bends, couplers etc. 6 The ends of the duct to be sealed with end plugs till OFC blowing is done. Important: The layingof OFC cable indepedently or along with Quad cable/PIJF cable in same trench shall be governed by the RDSO drawings no.RDSO/TCDO/COP-6 (a) and RDSO/TCDO/COP-8 (a) respectively issued vide Chapter XIII of The Telecom Manual. Inspection By-Site Engineer.
Blowing of OFC Cable in HDPE duct by mechanical system as per instruction of Railway engineer's representative at site. Inspection by-Site Engineer
Cutting of all type of platforms,trenching & excavation of depth of 300 mm x 300 mm wide approx.and refilling after laying of RCC/DWC/GI pipe in the trench and refilling and concreting it afterwards as per original condition. In hard rocky ground area, cables will be laid normally on layer of soft earth of 0.05 Mtr. thickness previously deposited at bottom of the trench. The cutting to be filled and finished with cement/concrete, as per the RDSO Dr.No.SDO/Cable laying/008, issued vide RDSO Document No.RDSO/SI/G/2010 Ver 1.1 Dt.4.2.2014 or latest. Inspection By-Site Engineer
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
STD-2022withAmndt1-111.pdf
ATTACHMENT
Generalconditions.pdf
ATTACHMENT
Scopeofworktechnicalspecifications.pdf scope of work and tech Speci
ATTACHMENT
JPO2.pdf
ATTACHMENT
Scopeofworktechnicalspecifications.pdf
ATTACHMENT