Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹36.4 LAccepted-AOC | ₹36.4 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹39.6 L+₹3.2 L (8.87%)Rejected-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | ₹39.6 L+₹3.2 L (8.87%) | L2 | Rejected-Finance Other then lowest bidder |
| 3 | L3₹40.0 L+₹3.6 L (9.92%)Rejected-Finance 274 210 DAFNALA ROAD SHAHIBAUG AHMEDABAD GUJARAT 380009 | AHMADABAD | GUJARAT | 380009 | ₹40.0 L+₹3.6 L (9.92%) | L3 | Rejected-Finance Other then lowest bidder |
| 4 | L4₹43.4 L+₹7.0 L (19.2%)Rejected-Finance | ₹43.4 L+₹7.0 L (19.2%) | L4 | Rejected-Finance Other then lowest bidder |
| 5 | L5₹44.4 L+₹8.1 L (22.1%)Rejected-Finance 101 VRAJ APARTMENT OPP POLICE HEAD QUARTERS SARU SECTION ROAD JAMNAGAR 381008 | JAMNAGAR | 381008 | ₹44.4 L+₹8.1 L (22.1%) | L5 | Rejected-Finance Other then lowest bidder |
Tender Value
₹54.8 L
EMD Value
₹1.1 L
Closing Date
3 Oct 2023, 6:00 pmClosed
Col Manish Dhaka CWE
HQ CWE (AF) Chiloda Military Engineer Services P.O CRPF Campus Vayu Shakti Nagar Gandhinagar 382042
PROVN OF VOLTAGE STABILIZER AND RING MAIN UNIT RMU FOR HT ELECTRIC SUPPLY AT AF STN WADSAR
2023_MES_616162_1
82154/CHL/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Wadsar
As per tender documents
7 documents required · 7 mandatory
₹1,000
Yes
GE (AF) Chiloda
₹1.1 L
11 Nov 2023
29 Aug 2023
10 Oct 2023
29 Aug 2023
3 Oct 2023
19 Sept 2023
30 Aug 2023 - 4 Sept 2023
Amount
Excavation in trenches not exceeding 1.5m width and not exceeding 1.5 m in depth and getting out in soft/loose soil complete all as specified and directed
Returning, filling in trenches, including spreading, levelling, watering and well ramming in layers not exceeding 25 cm in soft/loose soil complete all as directed.
M&L Dry sand cushioning to underground cable with screened, washed river sand, including punning gently all as specified and directed. Note: - Thickness after punning will be measured for payment.
Removal of excavated material at a distance not exc 50 m and depositing where directed at a level not exc. 1.5 m above the starting point in soft / loose soil complete all as directed.
Excavating in post holes each nexc 0.5cum getting out in soft/loose soil, and removing surfaces soil to a distance nexc 50m and making good surfaces
Supply and laying Burnt brick old size sub class 'B' laid in trenches a butting each other with a gap not exceeding 10 mm , vertically over the cable for cable protection complete all as specified .
M&L PCC 1:4:8 type D-2 using 40 mm graded stone aggregate as in foundations, filling and mass concrete complete all as specified
M&L PCC (1:3:6) type C-2 using 40mm graded stone aggregate as in foundation of posts and pillars etc complete all as specified
M&L Roof trusses (framed), trussed, purlins, crane, gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc and similar work confirming to Fe 290. Gde -E-165 complete all as specified and as directed
M&L Pre- painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550Mpa as in roof covering fixed with self tapping screws as specified and as directed by Engineer-in-Charge.
M&L Preparation of new steel surfaces of any description over 10cm width or grith not otherwise described and applying two coats of synthetic enamel paint over a coat of zinc chromate primer complete all as specified
Supply and laying Cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 11000 Volts grade with stranded aluminium conductor of size 95 sq mm3 core complete all as specified. Note:- Excavation / earth work will be measured and paid separately.
S&F Cable jointing kit for 11000 volts grade cable for indoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 core complete all as specified.
S&F Cable jointing kit for 11000 volts grade cable for outdoor termination joints, heat shrinkable type joint complete with jointing material and accessories suitable for XLPE armoured aluminium conductor cable of size 95 Sqmm 3 core complete all as specified.
Supply, install, testing and commissioning of outdoor type HT AVR (HT voltage stabilizer) of input voltage variation between 10 KV to 12.5 KV and output voltage 11 KV +1%, capacity 1250 KVA, 3 Phase, 50 Hz, 3 wire, manual bypass arrangement, suitable for balanced supply and unbalanced load, minimum losses, per IS 2026/77 with mode of operation automatic/manual/hand control, voltage correction speed 80 to 85 V/sec, suitable for all power factors suitable continuously duty cycle round the clock at full load, efficiency more than 99%,ONAN cooling, certified transformer oil as per IS 335,suitable operating tem 0 to 45 degree centigrade ambient temperature,imported high grade graphite rollers and used laminations of low losses CRGO laminations M4 grade, alongwith specification of construction of double copper wound stepdown & buck n boost transformer with open connected , copper auto wound and delta connected, with automatic control gear include electronic voltage relay, reversing geared motor unit, two limit switches in order to avoid over running highest and lowest positions, chain drive, coupling device and all electrical connections, OEM general arrangements, terminal arrangements, civil and foundation work, control and monitoring features as per specified by OEM and directed by Engr-in-charge.
M & L Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried in ground (earth pit not less than 2.25 Mtr deep below normal ground level with top edge of the plate not less than 1.5 Mtrs below normal ground level, connecting to the Galvanised iron earth lead 32 x 6 mm size by means of bolts, nuts check nuts and washers of galvanised iron and 32 x 6 mm dearth lead protection by provision of GI medium grade pipe 40 mm bore including provision of concrete pit in PCC (1:2:4) type B1 using 20mm graded stone aggregate with 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4gs/Sqm) and frame of angle iron 25mm x 25mm x 6mm with lugs 02 Nos and with 6 mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering perforated at the bottom 1.75 meter long placed on top edge of earth plate common salt and charcoal filling test point made out of 40mm x 8 mm FI with fixing arrangements, funnel, wire mesh and earth work in hard dense soil, returning filling in and removal of surplus soil to a distance not exceeding 50 Mtrs all as per electrical Plate No.5 of SSR Part I and connecting to earth test point all as specified or indicated including testing on completion Note: (i) Item includes the cost of 7.5 metre length GI pipe for protection of earth lead and earth lead . Any variation in length shall be adjusted through deviation order (ii) Earth resistance of earth pit should be less than 0.5 Ohms. On testing after completion if the desired earth resistance in not obtained the earthing will be redone at no extra cost
Supply, install, testing and commissioining of HT 11 KV, 3 phase, 50Hz, totally enclosed metal clad SF6 switchgear having rupturing capacity upto 630 Amps, outdoor type Non-Extensible fixed type (IP 54) , RMU (Ring main unit) 4-way comprising of 02 Nos 630 Amps, manually operated load break switch & 02 Nos. manual charging fixed-type vacuum circuit breaker, inside robotically welded stainless steel 34 Non Fertile nonmagnetic grade) tank having min. thickness 2.5 mm with IP 67 Degree of protection and enhanced BIL of 75 kVp internally to manage voltage surges. RMU shall be provided with internal busbars, as well as earthing busbars of electrolytic grade copper, padlock provision & complete with all accessories. The RMU shall be type tested for internal arc test of AFL 21kA/1 sec for tank as per IEC62271-200. RMU shall reparability features such as site replaceable bushing/coupling/mechanism and gas refilling at site. The earthing busbar shall be provided inside each cable compartment for solid earthing of Cable sheilds. The outer hinged main door should cover entire front of switchgear including cable doors for providing fall-safe protection. The unit shall include the following with all necessary standard fitting as required at site. (a) 02 Nos, Incoming and outgoing load break switch module consisting of following accessories : (i) 11 KV, 630A load break switch module and integrated earthing switch, both with full making capacity. (ii) Short time current-21kA/3-sec, making capacity-52kAP (iii) Auxiliary contacts-1NO + 1NC (iv) Fault pass Indicator-1 NO, for incoming LBS (v) Spring-assisted snap-action mechanism driven via shaft that remains un-inhabited after motorization, if required in future. (vi) Cable boxes with double-door arrangement for enhanced safety (IP54+IP3X) interlocked to prevent access to 3Cx300sqmm XLPE AL cable termination in live condition. Right angle boots (push on type)
(vii) Suitable site replaceable cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. (viii) Cable covers with self Interlocking mechanism with earth switch. (ix) Capacitive voltage indication fixed type system as per IEC61243 (b) 02 Nos, 0utgoing breaker module consisting of following accessories : (i) 11 KV, 630A fixed type vacuum circuit breaker module for making and breaking of fault current alongwith disconnector+Earth switch, of full making capacity. (ii) Short time current-21kA/3-sec, making capacity-52kAP (iii) Auxiliary contacts-1NO + 1NC (iv) Stored energy mechanism with manual spring-charging, associated closing/tripping coils, integrated non-removable spring-charging operating handle and ON/OFF push buttons mechanically latched to the mechanism interlocked Cable box for front termination of the cable suitable upto 3 core 300 Sqmm, 11 KV XLPE cable with double-door arrangement (IP54+IP3x). Safety interlocked to prevent access to cable termination in live-condition. (v) Right angle boots (push on type) (vi) Numerical based self-powered OC+EF protection Relay, providing over current (min. setting 20%), Earth-Fault (min. setting: 10%) (vii) 03 Nos 100/1, 2.5VA epoxy insulated, ring core CTs for protection (Acc, CI.5P10), installed away from bushings to prevent saturation of core. (viii) Suitable site replaceable cable bushings situated not beyond 300mm from cable-cover to allow ease of access for installation/testing/replacement purposes. (ix) Cable covers with self Interlocking mechanism between doors, earth switch, disconnector & VCB. (x) Capacitive voltage indication fixed type system (xi) Mechanical indications for breaker ON, OFF, EARTH, TRIP, Spring Charged-Discharged.
(c) Capacitive voltage indication fixed type VPIS 9-15 kV (d) Necessary interlocking arrangement for safety and operations (e) One No. operating handle for Manual operation and one no. manometer. (f) Safety Interlocks shall be provided as per relevant IEC/IS standards and Manufacturer’s directions. (g) Above switchgear shall confirm to all relevant IEC/IS standards. (h) Vacuum interrupter shall be of same make as RMU (j) Cable bushing shall be of replacable at site. (k) Minimum 5 module should accommodate in one tank to avoid multiple coupling at site.
Electricals India
ALBA AC AND REF SERVICES
M/S MECHANICAL ENGINEERING and ELECTRICAL CONTRACTORS
M/s SK Traders
M/s Prem Associates
Roy and Sons Infrastructers
Vardhman Airport Solutions Pvt Ltd
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .