Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.1 LAccepted-AOC 14 SURI LANE KOLKATA 700 014 | KOLKATA | KOLKATA | WEST BENGAL | 700014 | L1 | Accepted-AOC AOC | |
| 2 | L2₹18.5 L+₹3.4 L (22.3%)Rejected-Finance | L2 | Rejected-Finance Rejected as L2 | |
| 3 | L3₹19.5 L+₹4.4 L (28.8%)Rejected-Finance | L3 | Rejected-Finance Rejected as L3 |
Tender Value
Refer Docs
EMD Value
₹27,200
Closing Date
27 Sept 2021, 1:00 pmClosed
Executive Engineer
Dist Hosital campus Saktinagr Krishnagar Nadia
Electrical Mtc work of Electrical Sub Station situated near Ladies Hostel two under BCKV Mohanpur Nadia repairing and renovation of LT Panel Board and Transformer
2021_WBPWD_342339_1
WBPWD/EE/NED/NIT/e-T/13/ (2nd Call)21-22
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
Saktinagar Krishnagar Nadia
Please refer Tender documents.
5 documents required · 5 mandatory
₹27,200
29 Oct 2021
2 Sept 2021
29 Sept 2021
2 Sept 2021
27 Sept 2021
2 Sept 2021
Amount
Dismenteling old broken fully damaged HT gear (service voltage 11kv) having one incommer and two outgoing total three chamber type gear along with cables by removing it parts by parts or whole in proper way and stacking it properly as per direction of EIC
Dismenteling old partially damaged metal body type LT panel by disconnecting incomming and outgoing cables in proper way having incomming 400-600A and outgoings 315A (3nos), 200A(1 no),100A(1 no),32A(2 nos.) by removing it parts by parts or whole and stacking it properly as per direction of EIC
Supply of 11 KV unearth (UE) XLPE HT cable .(Approved make as per EIC) 3 Core x 185 sq.mm
Supply of 1.1 KV grade XLPE armoured type following size of cable (Make Gloster / Polycabe /RR kabel) 4 core 300 sqmm
3.5 core 240 sqmm
3.5 core 185 sqmm
3.5 core 150 sqmm
3.5 core 50 sqmm
3.5 core 25 sqmm
4 core 16 sqmm
Laying of one cable upto 150 sqmm through existing covered masonry trench incl. taking out RC covers,setting them in order, mending good the damages filling the trench with fine dry sand incl. supplying sand [4(a ) /F-3]
Laying of one cable above 150 sqmm and upto 300 sqmm through existing covered masonry trench incl. taking out RC covers,setting them in order, mending good the damages filling the trenchwith fine dry sand incl. supplying sand [4(b ) /F-3]
Charge for making heat shrinkable joints to the ends of 11 KV UE 3 core 185 sqmm XLPE HT cable at the HT gear and transformer ends with necy. jointing kits, sockets, sleeves, anti-corrossive paste, wires, solders, jointing compounds, rubber sheets etc. incl. supplying of necy. tools & tackeles for crimping the end sockets, soldering irons & making of glands at the both end of the cable as per directions of EIC(Make : Raychem / M -seal) [NS]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as bellow For 4 core upto 16 sqmm [7(c)/F-4]
For 3.5 core upto 25 sqmm [7(d)/F-4]
For 3.5 core upto 50 sqmm [7(d)/F-4]
For 3.5 core upto 150 sqmm [7(d)/F-4]
For 3.5 core upto 185 sqmm [7(d)/F-4]
For 3.5 core upto 240 sqmm [7(d)/F-4]
For 4 core upto 300 sqmm [7(c)/F-4]
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tape, anticorrosive paste & jointing materials. For 4 core 16 sqmm [8(b-xii)/F-5]
For 3.5 core 25 sqmm [8(b-xiv)/F-5]
For 3.5 core 50 sqmm [8(b-xvi)/F-5]
For 3.5 core 150 sqmm [8(b-xx)/F-5]
For 3.5 core 185 sqmm [8(b-xxi)/F-5]
For 3.5 core 240 sqmm [8(b-xxii)/F-5]
For 4 core 300 sqmm
Straight through jointing of cable of different size by compound jointing kit including S&F ferrul, tapes and jointing materials (Brand aproved by EIC) For 3.5/4 core 10-16 sqmm cable [10(iv)/F-6]
For 3.5/4 core 25-35 sqmm cable [10(v)/F-6]
For 3.5/4 core 50 sqmm cable [10(vi)/F-6]
For 3.5/4 core 120-150 sqmm cable [10(ix)/F-6]
For 3.5/4 core 185 sqmm cable [10(x)/F-6]
For 3.5/4 core 240 sqmm cable [10(xi)/F-6]
SITC of Indoor-type, floor mounted, metal clad, single panel, fully compartmentalized, free standing, Air insulated VCB, with Autoreclosing, System voltage : 11kV ± 5%, 50 Hz ± 5%, 3 Phase, Rated voltage : 12kV, Rated Current : 630A @ 40 °C ambient with 1 Nos VCBs (1 Incomer ), totally enclosed and fully interlocked , horizontal drawout, horizontal / vertical isolation type breaker as per IS 13188, as ammended upto date and as per detail specification attached (uploaded in the specification section) , [ Make : ABB / Siemens / CGL/Pascal ].
SITC of floor mounted Indoor type extensible cubical LV switchboard, fabricated by CPRI approved panel maker having compartmentalized design, fabricated out of 14 SWG ( 2.0 mm ) nominal thickness CRCA sheet steel,front and back openable, hinged, single shuttered, with 415V 630A FP MDO type incoming ACBs & Outgoing main switch and all accessories as per size, design & drawing to be approved by EIC and conforming to IS with latest modification and as per detail specification attached (uploaded in the specification section) [LT MAIN PANEL IN THE SUBSTATION]
Excavation of soil for installation of Earth Electrode and filling & ramming. For Soft Soil [1(a)/G-1]
Earthing with 80 mm dia GI pipe (TATA-Medium)x 3.0 Mts. long and 1 No. 65 mm x 8 mm galvanized (Hot Dip) steel strip (4 Mts. long), 20 mm dia x 125 mm long galvanized bolt, double nuts, double washers including finishing both ends by making holes etc. and S & F 80 mm dia GI pipe (ISI-Medium) protection (3 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level to an average depth of 3.65 Mts [2(e)/G-1]
Extra for providing masonery enclosure on the top of the earthelectrode of overall size 86.36 cm x 86.36 cm x 46 cm deep(below Ground level) complete with cemented brick work(1:6)of 25 cm width duly plastered with cement morter (inside) CIhinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe. [3(a)/G-2]
Extra for connecting the neutral of Transformer/Earth busbar to earth electrode including S & F Galvanized (Hot Dip) Steel strip 65 mm x 8 mm on wall/floor with GI saddles & insulating the same by one layer of PVC strip over one layer of ampere tape [6(d)/G-3]
Connecting the equipments body to earth busbar incl. S & F 50 mm x 6 mm Galvanized (Hot Dip) MS flat on wall/floor with GI saddle as required and connection to equipments with incl.drilling holes, bolts, nuts,washers etc. [5('e)/G-3]
Supply and fixing Rubber Mat (Best quality ISI approved) of size 4 ft. x 2 ft. x ½ inch. thick on floor of 11 KV Sub-station. [NS]
JAYBEECO
M/S N. C. HORE
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .