Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance | Admitted-Finance |
| 2 | Admitted-Finance | Admitted-Finance |
| 3 | Admitted-Finance | Admitted-Finance |
Tender Value
₹4.4 L
EMD Value
₹8,853
Closing Date
16 Sept 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
Assistant Engineer(Elect)
SHQ BSF Kishanganj
Maintenance of BFL Poles under 175 BN BSF under SHQ BSF Kishanganj (SH repair of loop cable, CG box and loop box ic connection)
2020_BSF_582529_1
166/SHQ-KNJ/Elect/2020
Open Tender
Electrical Works
Works
180 days
In AOR of 175 BN BSF under SHQ BSF KISHANGANJ
refer to NIT
6 documents required · 6 mandatory
₹500
Public Fund SHQ BSF Kishanganj
₹8,853
10 Oct 2020
9 Sept 2020
18 Sept 2020
9 Sept 2020
16 Sept 2020
9 Sept 2020
90 days
Amount
Excavation of Cable trench to draw cable and end termination work
Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. (i) Upto 35 sq. mm
Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 35 sq. mm
Excavation for cable trenches in soft soil, depth upto 1.2 m including dressing of sides lift upto 1.5 m, including getting out the excavated soil, refilling with sand and or good soil after laying of cable/ pipe etc in layers of 20 cm, ramming, watering and disposal of surplus excavated soil as directed, within a lead of 50 metres.
Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed/ XLPE aluminium conductor cable of 1.1 KV grade as required. (i) 3½ X 35 sq. mm (32mm)
CG box & Loop box change/ repairing work
Supplying and fixing of totally enclosed out door type dust and vermin proof control gear box ( CG box) with front openable hinged type door and locking arrangement of size 800mm x 550mm x 200mm (deep) made out of 2mm thick MS sheet welded construction , providing and fixing 4 Nos control cassets ( each suitable for mounting of one No. ballast , ignitor , one No. condensor, one No. SPMCB & one No. multiway terminal block) fabricated out of 2mm thick MS sheet including 1.6 mm horizontal partition with necessary clamps , earth terminal /studs and fixing of ballast , ignitor and condensor and SPMCB , 4 way multi way terminal, 2 Nos copper bus bar of size 20mm x 3mm , drilling holes on the clamps and bus bars i/c connections , interconnections with 2.5 sqmm FRLS grade PVC insulated copper conductor cable and making connections between the loop box and the CG box with 2 x 4 sqmm FRLS grade PVC insulated cooper conductor cable , i/c priming ,painting , earthing including providing necessary ventilators ( 02 Nos on each side ) with double brass wire mesh and water proof gasket , clamps and nut bolts etc complete as required i/c dismantling of the existing CG box and stocking the same in store as per direction of engineer in charge.
Supplying and fixing totally enclosed outdoor type front openable LOOP BOX with hinged type door and locking arrangement of size 325mm x 550mm x 200mm( deep) of welded construction fabricated out of 2mm thick MS sheet with necessary clamps and required quantity blanking holes suitable for 3.5 x 35sqmm PVC /XLPE UG cable including providing and fixing 4 Nos 100 amps aluminium bus bars and arrangement for fixing SPN MCB upto 40 Amps , drilling holes ,connections , interconnections ,priming and painting, earthing i/c providing necessary water proof gasket to the box ,nuts and bolts etc i/c MV danger notice plate of 200mm x 150mm made of mild steel at least 2mm thick and vitreous enamelled white on both sides and inscription in signal red colour on front side on the existing loop box complete etc as required i/c dismantling of the existing loop box and stocking the same in store as per direction of engineer in charge.
Providing and fixing of 100x58x1.90 mm mm size ISI marked M.S. pressed butt hinges bright finished with necessary screws etc. complete for repair of CG box and loop box door.
PRADIP KUMAR AGARWALA
HASIBUL RAHMAN
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .