Loading…
Loading…
Tender Value
₹7.8 L
EMD Value
₹7,813
Closing Date
10 Feb 2026, 6:00 pmClosed
Similar tender results from the same govt authority in the past 3 years.
The Chief Officer, Devgadh Baria Nagarpalika, Degadh Baria
BID DOCUMENTS FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS (GVP) AT VARIOUS AREA OF DEVGADH BARIA NAGARPALIKA.THIRD ATTEMPT
272027
2025-26 GVP Third Attempt
Open
Civil - All
Dahod
3 documents required · 3 mandatory
₹1,062
Chief Officer, Devgadhbaria Nagarpalika
₹7,813
2 Feb 2026
2 Feb 2026
2 Feb 2026
10 Feb 2026
2 Feb 2026
Total Amount Rs.
Note : 4 In all R.C.C. Items in Rate Analysis Standard Cement Consumption has been taken as per Govt. G.R.: PRC-
10/2017 Cement Consumption/16/C Date:11/05/2017 as stated in S.O.R. therefore in R.C.C. items
where there is a change as per actual mix design the cost of difference of cement consumption have been
deducted from the rate of original item at the rate of input rate mentioned in all the tender.
Signature of Contractor Chief Officer
Devgadh baria Nagarpalika
SECTION-7 BILL OF QUANTITIES-140
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) AT BANK OF BARODA NI SAME , AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 4.10 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 2.10 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 27.00 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 21.00 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 2.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-141
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 5.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-142
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-143
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-144
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-145
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) AT SBI NI SAME , AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 2.60 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 1.30 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 17.50 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 17.50 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 3.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-146
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 7.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-147
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-148
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-149
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-150
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) AT BANK OF PADAR CHOKDI , AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 2.70 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 1.40 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 18.00 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 20.00 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 3.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-151
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 7.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-152
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-153
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-154
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-155
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) AT CIVIL HOSPITAL NI BAHAR , AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 1.70 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 0.90 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 11.50 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 14.50 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 2.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-156
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 5.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-157
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-158
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-159
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
Providing Artistic 3D wall Painting on Serveral location up
to 10 Feet Height at Devgadhbaria nagarpalika
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-160
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) AT MOTA BAGICHA PACHAD, AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 2.60 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 1.30 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 17.50 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 17.50 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 2.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-161
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 4.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-162
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-163
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-164
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
[4-5-2]Add.1% Labour Cess.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
29 1.00 CCTV Camera. Trueview 4G Dual Lens Mini PT
Nos. Camera With 128GB Memory Card CCTV Surveilliance
System with all accessories and fixtures at 1 Surveillance
Points as directed by EIC.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-165
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) AT PAATRESHWAR MANDIR ROAD , AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 3.80 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 1.90 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 25.50 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 23.00 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 2.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-166
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 5.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-167
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-168
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-169
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-170
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) AT NANA TALAV NI SAME , AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 4.00 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 2.00 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 26.50 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 21.00 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 2.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-171
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 5.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-172
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-173
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-174
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-175
DEVGADHBARIA MUNICIPALITY, DEVGADHBARIA
NAME OF WORK :- ESTIMATE FOR DEVLOPMENT WORK OF GARBAGE VULNERABLE POINTS
(GVP) ATPANI NI TANKI SAME , AT DEVGADH BARIA.
Sr. Quantity Discription Total Unit Amount
1 1.70 Box Cutting the Road Surface to proper slope and
Cmt. camber for making a base for road work including
removing the excavated stuff and dipositing to road slope
as directed all lead and lift etc. complete upto 50 mt.
2 0.90 Providing and laying cement concrete (1:4:8) (1 Cement,
Cmt 4 Coarse sand, 8 Crushed stone agreegate 40 mm
nominal) and curing complete excluding cost of
formwork in foundation and plinth. (more than 10 ton)
3 11.50 Providing and fixing pre-cast Rubber Dye inter locking
Smt concrete block 60mm thick with grade of concrete M300
pnumatic compressed / Vibrated mechanically as per
approved design confirming to IS 15658 : 2006 including
35mm sand layer for levelling and filling the joint with
sand in proper line and level etc complete as per
guidelines of IRC : SP 63 -
4 14.50 Providing and fixing pre-cast concrete kerb stone of gray
Rmt cement based concrete block 30cm length,30cm height
and 15cm thick of M200 grade concret as per approved
design and including excavation for fixing in proper line
and level,filling the joint with C:M 1:3 (1cement:3fine
sand) etc complete.
5 2.00 Pre-cast Concrete Reinforced Bench . As Per Directed
Nos. Engi. In Charge Icluding Labour, Transpotation & All
Taxes. Etc complete.
SBD SECTION-7 BILL OF QAUNTITIES-176
6 1.00 Unbranded Stainless Steel Dust Bin 2 Bin Mounted with
Nos. Pole capacity 100 ltr
7 5.00 Planting shrubs in cement pots involves selecting a
Nos. suitable pot, preparing the soil, and planting the shrub
with proper care.
8 Supplying & erecting XLPE(IS:7098)(I)-88 ISI
unarmoured copper cable 1.1 KV grade to be erected as
directed of following size.
8.00 (E) 3 Core 2.5 sq. mm 136.35 Mtr.
9 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Control Cable.(c) One wire 2.50 sq. mm 26.26 Mtr.
10 Mains with ISI marked, 1.5KV grade electrolyte multi
stranded, annealed copper conductor with heat resistant
PVC insulated conforms to IS 694, IEC - 227 erected in
existing pipe of following size (Specifically for control
panel, relays, power switchgears, motor starters & control
wiring) with required size of copper lugs, nuts and bolts if
5.00 For Power Cable. (d) One wire 4.00 sq. mm 35.35 Mtr.
11 10.00 Providing and erecting XLPE (IS:7098)(I)-88 ISI
Mtr. armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in
existing trench / pipe of following size of cables.(e) 4 core
25 Sq. mm 188.87 Mtr.
12 1.00 Providing and erecting Miniature circuit breaker single
Ea. pole 6A to 25A suitable to operate on 240 V A.C. system
and having breaking capacity 10 KA to be erected in
existing box. confirming to IS 8828/1996 with ISI Mark.
Cat III 112.11 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-177
13 3.00 Providing and erecting Annealed bare Copper wire 8 to
14 1.00 Providing and erecting Pipe type earthing having
Ea. cms.long and 2.5 cms. dia. galvanised iron pipe with
coupling and buch buried in specially prepared earth pit
complete with necessary 8 SWG earth wire.
15 1.00 For using salt and charcoal/coke as required for pipe type 171.70 Ea.
16 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand /Solid Aluminium conductor
for 1.1 KV. To be laid on wall with necessary clamps or in
existing trench/pipe of following size of cables
10.00 (C) 4 core 10 Sq. mm 138.37 Mtr.
17 Providing and erecting XLPE (IS:7098) (I)-88 ISI
armoured cable multistrand Aluminium conductor for
KV. to be laid on wall with necessary clamps or in existing
trench / pipe of following size of cables
2.50 (C) 4 core 16 Sq. mm 151.50 Mtr.
18 10.00 Providing & laying approved make Double walled
Mtr. corrugated pipes (DWC) of polyethylene (conforming to
IS 14930 II) with necessary connecting accessories of
same material at required depth in existing trench for
laying of cable. below ground / road surface for enclosing
cable. (C) 50 mm Dia
19 Supplying following size of Light duty “A” Class G.I. Pipe
& erecting as directed by Engineer-in-charge.
2.50 (B) 50 mm dia 300.98 Mtr.
20 Providing and fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 10 Sq. mm 38.38 Ea.
SBD SECTION-7 BILL OF QAUNTITIES-178
21 Providing and, fixing heavy duty flange type brass cable
gland with rubber ring for PVC insulated armoured cable
complete with out going tails, insulating tape etc for
following size of cables.
2.00 (d) 2 to 4 core 25 Sq. mm 51.51 Ea.
22 1.00 Supplying and erecting approved make Octagonal pole
Ea. made from HR sheet steel. The pole should be made as
per IS. and shall be coated with hot dip galvanizing as per
IS 2629/2633/4759, suitable suspend local wind speed
with integral Junction box consist of terminal plate of min
6mm Hylam sheet, standard profile 35mmX7.5mm Din-
Rail for MCB Mounting, stud type terminal and
arrangement for cable termination to be erected With
Suitable foundation (Included) as per details given by
manufacturer considering site requirement. (D) 6 Mtr.
Long 70 mm Top X 135 mm bottom dia, 3 mm thickness
with 200mmX200mmX12mm base plate, 4-M20 Bolts
and 600mm long with necessary G.I. J Bolts .Approx
Pole weight 59 kgs.
23 Providing and erecting Street Light pole bracket
comprising main B Class MS pipe of 4.2 cm/require
outside dia. complete with suitable B Class M.S. sleeve
tubing of approx. 45cms.length and suitable for 76.5 mm
/80mm / required size of pole top having sufficient
fasteners for fixing the brackets and having spread of
1.5.mtr. length with 110 deg.with vertical plane & suitable
welded stays, reducer and with check nuts complete
painted with one coat of Red oxide / PU base primer and
two coats of Aluminium / PU paint. paint with following
1.00 (A) Single Arm Bracket 1.5 Mtr. 626.20 Ea.
0.00 (B) Double arm Bracket 1.5 Mtr. 916.07 Ea.
24 1.00 Supplying and erecting LED street light / Flood light
Ea. fittings with High power White LEDs wattage of 3 Watt
and above assembled on single MCPCB, efficiency more
than 130 lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder coated and
heat sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses, with toughened glass with
company mark/name engraved or embossed 160 to
V,Power Factor more than 0.95, THD < 10 %, CCT
K to 5700K, Uniformity ratio >0.45, Luminaire efficacy>
100 lumens/watt. LED driver efficiency > 85 %.( fittings
required LM-79 & LM-80 certificates) (NOTE: Below
description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any
wattage capacity between the ranges shown.) (A) Street
Light (IP-65), Surge protection -4KV integral and Light
must have 440VAC line supply with over-voltage
protection. (ii) above 36 to 48 Watts. Cat III
SBD SECTION-7 BILL OF QAUNTITIES-179
25 1.00 Supplying & erecting power contactor, AC3 duty for time
Ea. switch complete erected as per direction Cat III. (B)
pole 250V 32 Amp. 1883.65 Ea
26 1.00 Supplying & erecting approved make SMC press
Ea. moulded composite FRP. loop-in, loop- out approx. 2mm
thick box complete with Bakelite connector strip
5way(3P+N+E), DIN rail for mounting mob & hinged
doors as per requirement having locking arrangements
with mounting clamp with nuts, bolts & washers suitable
for erection on pole with cable clamps& earth bolt of
following size of box. (c) 150mm x 125mm x 100mm
[deep]. 476.72 Ea.
27 10.00 Making trench in Hard Murrum / Tar Road of suitable
Mtr. width of 90 cm or required depth for laying any size of
cable or locating the fault all over the run and back filling
the same and making the surface as normal ground.
28 10.00 If additional machinery like hammer driller or JCB use
Mtr. [Add] 297.95 Mtr.
Providing Artistic 3D wall Painting on Serveral location up
29 11.15 to 10 Feet Height at Devgadhbaria nagarpalika 1484.70 sqm
Add :- 18% of GST, Rs.
Add :- 2% of Contingency Charges, Rs.
Add :- 1% of Qaulity Controll, Rs.
SBD SECTION-7 BILL OF QAUNTITIES-180
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
BOQ.pdf
Notes.pdf
OTHER IMPORTANT DOCUMETS-1.pdf
OTHER IMPORTANT DOCUMETS-2.pdf
OTHER IMPORTANT DOCUMETS-3.pdf
SBD.pdf
Download all tender documents and submit your bid