Assistant Engineer
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrical Sub-Division, PWD Kalyani, Nadia
Electrical work for concealed-type split Air Conditioners at the PICCU unit of COM and JNM Hospital, Kalyani.
2024_WBPWD_731751_1
WBPWD/AE/e-NIT- 08/KLY of 2024-25
Open Tender
ELECTRICAL WORKS ORG
Item Rate
10 days
COM and JNM HOSPITAL, KALYANI
Please refer Tender documents.
4 documents required · 4 mandatory
₹6,832
OFFICE OF THE ASSISTANT ENGINEER Kalyani Electrica
28 Apr 2025
9 Aug 2024
23 Aug 2024
9 Aug 2024
21 Aug 2024
14 Aug 2024
13 Aug 2024
Amount
Supplying and fixing 415 V, 160 A TPN SFU (Make - Siemens/ L&T/ Havells) with sheet steel enclosure on angle iron frame on the wall with nuts bolts etc. incl. S & F 3 nos. DIN type HRC fuse as per rating. [4(a)/D-3]
S & F of 415 V, double door, 6 way, VTPN MCB DB (Make - Legrand / ABB Elegance / Schneider / Siemens) for 160 A MCCB incomer, 63 A SP/TP MCB as outgoing with IP-43 protection, concealed in wall & mending well the damages to original finish incl. interconnection with suitable size of copper wire and neutral link & provision for earthing attachment. [15/D-11]
S & F of 415 V, 4 ways, double door, sheet steel enclosure, IP-43 protection, HTPN MCB DB (Make - Legrand / ABB Elegance / Schneider / Siemens) with DIN RAIL concealed in the wall after cutting the wall & mending well the damages to original finish as a three-phase timer DB comprising with 1 no. 415 V, 40 A FP MCB ('C' Curve, 10 kA), 1 no. 24-hour programmable Time Switch with a minimum switching time of 15 minutes, 1 no. 415 V, 40 A 3 pole contactor, 1 no. Auto-Manual bypass Toggle Switch, 2 nos. ON-OFF indication LED lights complete with internal wiring by suitable size of copper wire including provision for neutral link & earthing attachment. (Make of MCB, Time Switch and Contactor would be same as per make of MCB DB)
S & F of 415 V, 4 module hot press moulded CMC MCB DB box (231 mm x 166 mm x 113 mm) with DIN RAIL, earth bar, neutral bar, transparent window, IP-65 protection and resistant to chemical and atmospheric agent (Make - Sintex, Model no. SIL-CDN4PT/RR) on the wall.
S & F of 415 V, 4-way 160 A, FP MCCB (Make - Legrand / ABB / Schneider / Siemens) of breaking capacity 36 kA with adjustable thermal and fixed magnetic setting in VTPN DB and necessary connection. [10/D-8]
S & F of 415 V, 40 A TP MCB of breaking capacity 10 kA & 'C' characteristics (Make - Legrand / ABB / Schneider /Siemens) on din rail of VTPN DB and necessary connection. [7/D-6]
S & F of 415 V, 40 A FP MCB type Isolator (Make - Legrand / ABB / Schneider / Siemens) on din rail of MCB DB and necessary connection. [6/D-5]
Supplying and fixing double door sheet steel (16 SWG), powder coated cable end box for 4 ways VTPN MCB DB enclosure with IP-43 protection on angle iron frame on wall & mending good the damages to original finish with nuts bolts etc incl. provision for earthing attachment. [16/D-12].
Cutting Channel of 43 mm x 43 mm on masonry wall by Electric operated cutting machine incl. supplying & fixing heavy gauge 25 mm diameter 3 mm thick polythene pipe using anchoring chemical (Hilti/Sika), GI 'U' hooks of 8 SWG, 18 SWG GI wire as fish wire and mending good damages to original finish by using own tools and tackles without earth continuity wire. [6(a)/E- 3]
Supplying and Drawing 1.1 KV Gr. 4 x 6 sq. mm + 2 x 4 sq. mm. single core stranded 'FR' PVC insulated & unsheathed stranded copper wire (Make - Finolex/Polycab/Havells/RR Kabel) of the following sizes in the pre-laid polythene pipe as per GS. [1(y)/E- 9]
Finishing the 4 x 6 sq. mm + 2 x 4 sq. mm PVC insulated wire ends by socketting with pin/ring type copper sockets and insulated tapes etc., including supplying sockets and tapes. [9/F-5]
Supply and delivery of the following sizes 1.1 kV Gr. 4 Core PVC/XLPE Insulated & Sheathed Armoured Aluminium Conductor Cable (Make - Polycab / Havells / Universal / RR Kabel)
4 core 10 sq. mm cable
4 core 70 sq. mm cable
Supplying & fixing of 40 mm dia medium gauge GI pipe (ISI medium - Zindal / Bansol / Tata) protection with necessary fittings and jointing materials as required. [11(c)/F-6]
Laying of following sizes Ar. Al. the cable on the wall/surface incl. S & F MS saddles/clamps with earthing attachment in 2 x 10 SWG GI (Hot-Dip) wire, making holes etc. as necy. mending good damages and painting -
3 core 10 sq. mm cable [2(b)/F-1]
4 core 70 sq. mm cable [2(d)/F-1]
Laying of 4 core cable as below, after cutting floor/ pavement/wall and making holes incl., embedding the cable at an average depth as below and mending well the damages to original finish incl. removing the rubbish ------
10 sq. mm at an average depth of 75 mm in floor/pavement/wall etc. [5(i)/F-3]
70 sq. mm at an average depth of 100 mm in floor/pavement/wall etc. [5(ii)/F-3]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture proof entry of following XLPE/PVÇ Armoured cables as below:
4 core 10 sq. mm cable. [7(c)/F-4]
4 core 70 sq. mm cable. [7(c)/F-4]
Finishing the end of following XLPE/PVC armoured cables by cimping method incl. supplying and fixing solder less socket (Dowels make), tapes, anticorrosive paste & jointing materials. [8(b)/F-5]
4 core 10 sq. mm cable
4 core 70 sq. mm cable
T.D.K. ENTERPRISE
KANJILAL and SONS
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .