Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹21.3 LAccepted-AOC | ₹21.3 L Quoted ₹22.0 L | L1 | Accepted-AOC Lowest Bidder |
| 2 | L2₹22.9 L+₹89,670.10 (4.08%)Rejected-AOC 14 4A KALI PRASAD C HAKRABORTY ST CAL KOLKATA 700003 | KOLKATA | WEST BENGAL | 700003 | ₹22.9 L+₹89,670.10 (4.08%) | L2 | Rejected-AOC High Rate |
| 3 | L3₹23.2 L+₹1.2 L (5.42%)Rejected-AOC 71 A LOOTERY MAHAL ORDERLY BAZAR PO BARRACKPORE DIST 24 PARGANAS N KOLKATA 700120 WB | 24 PARAGANAS NORTH | WEST BENGAL | 700120 | ₹23.2 L+₹1.2 L (5.42%) | L3 | Rejected-AOC High Rate |
| 4 | L4₹23.3 L+₹1.3 L (6.07%)Rejected-AOC | ₹23.3 L+₹1.3 L (6.07%) | L4 | Rejected-AOC High Rate |
| 5 | L5₹23.3 L+₹1.4 L (6.25%)Rejected-AOC | ₹23.3 L+₹1.4 L (6.25%) | L5 | Rejected-AOC High Rate |
Tender Value
Refer Docs
EMD Value
₹40,000
Closing Date
10 Aug 2021, 6:00 pmClosed
GE AF Barrackpore
GE AF Barrackpore Post Barrackpore Dist 24 Parganas North Kolkata 700120
REPAIR /MAINTENANCE OF CEILING FAN, EXHAUST FAN AND ALLIED WORKS AT 6 WG, JAFFARPORE, KANCHRAPARA, LOS DUM DUM AND BARASAT UNDER GE (AF) BARRACKPORE
2021_MES_438247_2
8287/BKP/AF OF 2021-22
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
6 WING, JAFFARPORE, KANCHRAPARA, LOS DUM DUM
Pl refer tender documents
5 documents required · 5 mandatory
₹500
GE AF Barrackpore
₹40,000
Yes
27 Aug 2021
30 Jul 2021
12 Aug 2021
30 Jul 2021
10 Aug 2021
31 Jul 2021
Amount
Taking down ceiling fan of 1200mm sweep, exhaust fan(300/380mm sweep), air circulator(400mm sweep) and pedestal fan(400mm sweep) by unscrewing nut/bolts from its position and fixing the same to its original place after necessary cleaning, oiling, greasing, replacement of bush, bearing, capacitor as directed by Engr-in-Charge. (Note :(i) Bush, bearing shall be measured as supply only and paid separately and fixing charges for spare parts shall deemed to be included in the item.
All as per Item No.1 here-in-before but ceiling fan of 1400 mm sweep exhaust fan(400/450mm sweep), air circulator(450mm sweep) and pedestal fan(450mm sweep)
M&L for painting of ceiling fan of 1200mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed by Engr-in-Charge. (Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 1 above)
M&L for painting of ceiling fan of 1400 mm sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed by Engr-in-Charge. (Note :- Taking down and refixing of ceiling fan shall be measured and paid against item no 2 above)
M&L for painting of exhaust fan/pedestal fan/air circulator any sweep by scraping/removing old paint with brush/emery paper and spray painting with two coat of synthetic enamel paint including marking of MES number complete all as specified and directed by Engr-in-Charge. (Note :- Taking down and refixing of exhaust fan/pedestal fan/air circulator shall be measured and paid against item no 1 above)
Taking down/ dismantling complete ceiling fan of size 1200mm sweep down rod with its canopies, shackle, capacitor housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :-(a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan including fixing only old/new spare parts (i.e.) rubber bush of shackle and capacitor housing, capacitor, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :-(i) Ball bearing and Gun metal bush shall be measured as supply only and paid separately and fixing charges for spare parts shall deemed to be included in the item (ii)Taking down and refixing of ceiling fan/exhaust fan/air circular shall be measured and paid against item no 1 above)
All as per Item No.6 here-in-before but ceiling fan of 1400 mm sweep .
All as per Item No.6 here-in-before but exhaust fan of 300/380 mm sweep .
All as per Item No.6 here-in-before but exhaust fan of 400/450 mm sweep .
All as per Item No.6 here-in-before but pedestal fan/air circulator any sweep.
Repairs to ceiling fan (Old model) of size 1200/1400mm sweep down rod with its canopies, shackle, capacitor housing with its rubber bushes, split pins, unscrewing the body parts of ceiling fan, taking out starter, rotor winding ball bearing, gun metal bush etc. complete to carry out the following repairs :-(a) Removing of burnt out fan winding and re-winding of motor with suitable size of copper enamelled wire, varnishing, heating as per manufactures design and directed and re-assembling complete ceiling fan including fixing only old/new spare parts (i.e.) rubber bush of shackle and capacitor housing, capacitor, gun metal bushes, ball bearing, twin twisted copper cable, etc complete all as specified and directed by Engineer-in-charge. (Note :-(i) Necessary lath machine work for Gun metal bush housing replace with ball bearing housing (ii) Ball bearing and Gun metal bush shall be measured as supply only and paid separately and fixing charges for spare parts shall deemed to be included in the item (iii)Taking down and refixing of ceiling fan/exhaust fan/air circular shall be measured and paid against item no 1 & 2 above)
Supply only for capacitor 2/2.5 MFD (Metal body)
Supply only for capacitor 3.5/4 MFD (Metal body) .
Supply only for rubber bush for shakle with bolt ,nut and lock pin suitable for ceiling fan 1200 / 1400 mm sweep
Supply only for PVC holder for capacitor housing
Supply only for ball bearing number of 6202 as required.
Supply only for ball bearing number of 6203 as required.
Supply only for ball bearing number of 6201 as required.
Supply only for ball bearing number of 6204 as required.
S&F ceiling fan spindle complete all as specified and directed.
Supply only gun metal bush as required
M & L for mini steped type electronic fan regulator flush type on thee existing phenolic laminated sheet etc all as specified and directed.
M & L for Delux steped type electronic fan regulator flush type on thee existing phenolic laminated sheet etc all as specified and directed.
M&L for modular fan regulator ,step type ,120 Watt,W-2 module complete all as specified and directed by Engr-In-Charge.
M&L for wall/air circulator/stand fan PVC blades 300 mm sweep complete all as specified and directed by Engr-In-Charge.
M&L for wall/air circulator/stand fan PVC blades 350/380 mm sweep complete all as specified and directed by Engr-In-Charge.
M&L for exhaust fan louvers with shutters suitable for 300/380/450 mm sweep for exhaust fan complete all as specified and directed by Engr-In-Charge.
M&L for exhaust fan blade (metal body) suitable for 300/380/450 mm sweep for exhaust fan complete all as specified and directed by Engr-In-Charge.
M&L ceiling fan, fan blade suitable for 1200 mm sweep for complete all as specified and directed by Engr-In-Charge.
M&L ceiling fan, fan blade suitable for 1400 mm sweep for complete all as specified and directed by Engr-In-Charge.
Supply and fixing of 1200/1250 mm sweep BEE 5 star rated antidust dermin proof ceiling fan complete with all accessories,230V and remove the UNSV ceiling fan, deposited to MES store yard and all as specified and directed.
M & L for 50x6mm thickness MS strip with nut,bolt and washers suitable for fixing of ceiling fan and all as specified and directed
Removal of UNSV, S&F Exhaust fan steel body AC single phase 230 V of size 380 mm sweep with blades, frame & louvers.
Taking down the rusted down rod of ceiling fan of size (1') , S&F new down rod to any height including two coats of synthetic enamel paint complete all as specified and directed by Engr-In-Charge.
Taking down the rusted down rod of ceiling fan of size (2') , S&F new down rod to any height including two coats of synthetic enamel paint complete all as specified and directed by Engr-In-Charge.
Removal of UNSV, S&F Exhaust fan steel body AC single phase 230 V of size 450 mm sweep with blades, frame & louvers.
S &F the canopy suitable for ceiling fan of existing type & size complete all as specified and directed by Engr-In-Charge.
M&L for PVC insulated Single core 1.5 sqmm 3 core multi strand copper conductor for the connection of ceiling fan from ceiling rose to ceiling fan complete all as specefied and as directed.
ROY CONSTRUCTION
KUMAR ENTERPRISE
BHAUMIK CONSTRUCTION
APOLLO TRADERS
BUSINESS SYNDICATE
SARKAR AND COM
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .