Loading…
Loading…
Tender ID
Tender Value
₹4.8 Cr
EMD Value
₹4.8 L
Closing Date
24 Mar 2026, 6:00 pmClosed
Municipal Commissioner
Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical, Instrumentation and Civil works for Water Distribution Station At Bodakdev ADB and Bodakdev Trilok of North West Zone of AMC.
282526
2025-26
Open
Miscellaneous Works
Works
Ahmedabad
2 documents required · 2 mandatory
₹6,000
Municipal Commissioner, Ahmedabad
₹4.8 L
3 Mar 2026
3 Mar 2026
3 Mar 2026
24 Mar 2026
3 Mar 2026
estimated cost, as mentioned above. Amount of my / our tender works out for Rs. ________________ (in figures)
Estimated amount put to tender Rs. Estimated amount put to tender Rs.
2) Lump Sump Amount Quoted for Buy Back Items (as per Annexure-I) in Scope of Work (Section A-4, A.4.2), Rs. _____________
Signature of Contractor
Company’s seal :
1. Bidder has to quote % Above (Premium) or % Below (Discount) or As part of total Job, Rs. 4,79,22,232/- (i.e.
Total Estimated Project Cost w/o buyback value) and has to carry out work at Ordered Value with any Excess -
Less Qty. mentioned in above items as per site requirement and instruction of Engineer-in-charge.
2. Bidder shall quote for buyback items as per Annexure-1 in Scope of Work, Section A-4(A.4.2) separately
online at Sr. 2 as indicated above. Bidder to note that net amount quoted by the bidder shall be determined by
deducting the total amount of buyback quoted by bidder from the amount quoted for works as above at Sr. No.
deducting the total amount of buyback quoted by bidder from the amount quoted for works as above at Sr. No.
1 and the net amount so derived shall be considered for Price Evaluation purpose to determine lowest bid.
TOTAL SUMMARY OF COST
Name Augmentation work with SITC of Pumping Machinery with related Mechanical,
Of Electrical, Instrumentation and Civil works for Water Distribution Station At
Work Bodakdev ADB and Bodakdev Trilok of North West Zone of AMC.
ITEM DESCRIPTION AMOUNT
A BODAKDEV ADB WDS CAPITAL COST
B BODAKDEV TRILOK WDS CAPITAL COST
C TOTAL OF CAPITAL COST (A + B) (EXCLUDING GST)
BUY BACK AMOUNT IN RS. (BODAKDEV ADB WDS)
(AS PER ANNEXURE-I)
BUY BACK AMOUNT IN RS. (BODAKDEV TRILOK WDS)
(AS PER ANNEXURE-I)
F TOTAL BUY BACK AMOUNT IN RS. (D+E)
TOTAL AMOUNT AFTER DEDUCTION OF BUY BACK
TOTAL AMOUNT AFTER DEDUCTION OF BUY BACK
VALUE IN RS. (C-F)
SUMMARY OF COST
Name of Augmentation work with SITC of Pumping Machinery with related Mechanical,
Work Electrical, Instrumentation and Civil works for Water Distribution Station At Bodakdev
ADB of North West Zone of AMC.
SR. NO. ITEM AMOUNT
A. MECHANICAL WORK
B. INSTRUMENTATION WORK
C. ELECTRICAL WORK
E. TOOLS & TEST EQUIPMENTS
TOTAL AMOUNT OF CAPITAL COST (A + B + C + D + E)
TOTAL AMOUNT OF CAPITAL COST (A + B + C + D + E)
F. (EXCLUDING GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev ADB of North
Work West Zone of AMC.
MECHANICAL WORK
ITEM QTY UNIT RATE (in
1.1.1 HORIZONTAL SPLIT CASING 4 Nos. 6,27,950.00
CENTRIFUGAL PUMP WITH MOTOR
Supply, installation, testing and commissioning of
horizontal mounted, side suction & side delivery
type Horizontal Split Casing Centrifugal Pump
having CI Casing, CF 8 M impeller & wear rings,
SS410 Shaft & shaft sleeves, Mechanical seal and
suitable to couple with TEFC squirrel cage IE3
efficiency class Induction Motor, 3 Phase, 415 V,
50 Hz., AC supply, max. 1500 RPM synchronous
speed. The scope shall also include all required
accessories viz. CI drain rim type base plate, Flex.
coupling, coupling guard, foundation bolts, min
mm dia. G.I. Class-B drain pipe upto drain channel,
etc. as per specification.
Capacity : 500 m³/hr
Motor Rating : 75 KW or as per Manfactuer
The scope also includes chipping, grouting, altering
the civil foundation to suit the new pumpset as
required and removal of debries and cleaning the
INDUCTION MOTOR FOR ABOVE HSCF
Supply Installation Testing and Commissioning
(SITC) of approved make, energy efficient,
Efficiency Class-IE3, horizontal foot mounting,
solid shaft, squirrel case, Induction Motor rating
mini 75 kW or higher as per IS, 3-Phase, 415V,
50Hz., AC supply, maxi.1500 RPM synchronous
speed and having TEFC enclosure with Class F
insulation (temp. rise limited to Class B) with
2.1.1 VALVES 1 Nos. 3,057.00
Supply, Installation, testing and commissioning
of Manually gear operated CI/DI Double Flanged,
Rising Spindle type, Sluice Valve conforming to
IS 14846 PN 1.0 with SS 304 seat rings and SS
spindle with hot dipped galvanised hardware's,
bolts, nuts & washers, gaskets, etc. as per data
Size : 50 mm NB (Manually Operated - On delivery
pipe of Dewatering Pump )
2.1.2 VALVES 1 Nos. 38,465.00
Supply, Installation, testing and commissioning
of Manually gear operated CI/DI Double Flanged,
Rising Spindle type, Sluice Valve conforming to
IS 14846 PN 1.0 with SS 304 seat rings and SS
spindle with hot dipped galvanised hardware's,
bolts, nuts & washers, gaskets, etc. as per data
Size : 350 mm NB (Manually Operated - On
Suction pipe of HSCF Pump )
2.2.1 Supply, installation, testing and commissioning of 4 Nos. 1,51,212.00
Electrically gear operated CI/DI Double Flanged,
Rising Spindle type, Sluice Valve with actuator,
integral starter,etc. conforming to IS 14846 PN
with SS 304 seat rings and SS spindle with all hot
dipped galvanised hardware's, bolts, nuts &
washers, gaskets, etc. as per data sheet.Size:
300mm NB (Electrically Operated - On Delivery
2.2.2 Supply, installation, testing and commissioning of 5 Nos. 1,63,465.00
Electrically gear operated CI/DI Double Flanged,
Rising Spindle type, Sluice Valve with actuator,
integral starter,etc. conforming to IS 14846 PN
with SS 304 seat rings and SS spindle with all hot
dipped galvanised hardware's, bolts, nuts &
washers, gaskets, etc. as per data sheet.
Size: 350mm NB (Electrically Operated -
Installation location as directed by Enng. in charge
2.2.3 Size: 400 mm NB (Electrically Operated - 5 Nos. 1,79,819.00
Installation location as directed by Enng. in charge
2.2.4 Size: 450 mm NB (Electrically Operated - 5 Nos. 1,92,251.00
Installation location as directed by Enng. in charge
2.3.1 Supply, installation, testing and commissioning of 4 Nos. 37,587.00
double flanged CI/DI Dual Plate Check Valve
conforming to API 594 Class 300 / PN 1.6 with CS
dual door, hinge pin & stop pin of SS 410 , springs
of AISI 304 and seat rings of SS 304 ( renewable ),
along with all required accessories, gaskets and
hardwares,etc. and as per specification.
Size : 300 mm NB (On Delivery Pipe)
3.1.1 Supply,Installation,Testin and Commissioning of 4 Nos. 12,840.00
double flanged Expansion Bellows confirming to
EJMA/IS standard with PN 1.0 rating & all
necessary St.St. hardware's.Size : 350 mm NBx
mm ( L )(On Suction Pipe)
3.1.2 Size : 300 mm NBx 300 mm ( L )(On Delivery Pipe 4 Nos. 10,200.00
4.1.1 SITC of CI flanged reducer/expander 4 Nos. 5,568.00
conforming to IS 1538 with gaskets, hardware and
required accessories as per specifications.
Size: 350 mm X 250 mm X 600 mm (L)
Note:-(Suction Reducer- 250 mm or size as per
Actual HSCF Pump Suction Flange) (Reducer
Length Size shall be as per Actual Site Requred)
Note:- (Delivery Expander- 200 mm or size as
per Actual HSCF Pump Delivery Flange)
(Reducer Length Size shall be as per Actual Site
5.1.1 Flanged Joints of Pipes, Fittings and Specials: 10 Nos. 434.00
Supply, Installation, Making of Flanged CI & GI
Pipes, Fittings and Specials Joints with all jointing
materials, rubber packing, nut bolts, labour etc.for
complete connection.
Size: 50 mm dia
5.1.2 Size: 200 mm dia 4 Nos. 837.00
5.1.3 Size: 250 mm dia 4 Nos. 1,007.00
5.1.4 Size: 300 mm dia 24 Nos. 1,223.00
5.1.5 Size: 350 mm dia 16 Nos. 1,442.00
6.1.1 M.S. PIPES & SPECIALS 15 RMT 5,752.05
Supply, Gas cutting of pipe, Fabrication, welding,
Installation, testing and commissioning of MS pipe
& Specials conforming to IS 3589 & flanges
confirming to IS 6392-PN-1.0, fabricated from MS.
plate with necessary supports & anchoring. Pipe
fabricated from MS plate. (Excluding supply of
Size: 300 mm NB X 10 mm Thk
6.1.2 Size: 350 mm NB X 10 mm Thk 10 RMT 6,332.76
6.2.1 MS FITTINGS & SPECIALS: 1000 KG 70.67
Supply, Fabrication, Gas cutting of pipe, welding,
Installation, testing and commissioning of MS
flanged / plain ended specials and fittings like MS
reducer, expander, Metering bends, Tees, etc.
conforming to IS 3589, flanges confirming to IS
6392-PN- 1.0, fabricated from MS. plate with
necessary supports & anchoring. Pipe fabricated
from MS plate. (Excluding supply of flange)
Size: 350 mm NB mm x 10 mm Thk and Above
The scope also includes civil work, casting PCC
thrust block, chipping, grouting, supporting,etc.
require for laying & connecting the MS pipes &
fittings as require outside the pump house
6.2.2 Size: 350 mm NB mm x 10 mm Thk and Above 1000 KG 70.67
6.3.1 Providing epoxy coating to inside and outside pipe 14 Sq.m 332.00
line with two parts of Solvent free high build liquid
epoxy lining as per AWWA C210-07 Suitable for
potable water application & shall be approved by
CFTRI- India/BS 6920-UK/international standard
/NSF/ANSI/-61 2004 to be fit for contact with
potable water for human consumption with
micron thickness. inclusive of necessary materials
, labour ,Equipment ,Contractor's overhead charges
and profit and including all taxes.Size: 300 mm NB
6.3.2 Size 350 mm NB 11 Sq.m 332.00
6.4.1 Supply, welding , Installation, testing & 16 Nos. 3,930.78
commissioning of MS flat machined faced
flanges confirming to IS 6392 & drilled as per IS-
1538 with drilling off centre bolt holes and flange
thickness as per PN 1.0 including cutting &
Size : 300 mm NB Drilled
6.4.2 Size : 350 mm NB Drilled 8 Nos. 5,060.72
7.1.1 G.I. PIPES & FITTINGS: 15 RMT 387.00
Supply, installation, connection with equipments as
required, testing and commissioning of GI pipe
conforming to IS-1239 , Medium Duty with
coupling, tee, bend, union, elbow, flanges , etc as
all required fittings for connection complete with
gaskets, hardware, and required accessories as
per IS & Specifications
Size: 50 mm NB(For dwatering Pump)
8.1.1 DEWATERING PUMPS 1 Nos. 1,46,348.00
Supply, erection, testing and commissioning of
Non Clog Submersible Pump with C.I. casing &
CF8M impeller, including necessary accessories
and hadrwares, etc., 25m cable as required suitable
for 3 phase, 415 V, 50 Hz AC supply with min.
HP motor and necessary safety futures along with
pump monitoring unit for auto stop facilities, cable
termination / juction box of required terminal size,
supporting arrangement for pump and other
required accessories to be installed in dry well
Capacity: 30 m3/hr
Head: 15 m. Motor Rating: Mini. 2.2 kw (or higher
rating as reco. by pump manufacturer)
9.1.1 E.O.T. CRANE WITH HOIST 1 Nos 5,06,250.00
Providing & erecting Single girder type fully
electrically operated E.O.T. crane with electrically
operated hoist, class II duty, geared travelling
trolley with seven meter lift complete with long
travel rail track (40 mm sq. bar), moving or cross
girder, all three motions electrically operated by
suitable rating motor IP 54, control panel & down
pendant control block, brake, safety device, cables
form motor to starter panel & other required
accessories & tested as per IS Specifications.EOT
Crane with single/Box type girder having
motorised motion in all three directions,
manufactured as per IS - 807, IS 3938 & IS -
, class-II, complete with electrically operated hoist,
geared trolley, cross girder, rail track, brake, wire
rope drum, motors, safety device, pendant push
button, starter panel, cables from motor to starter
panel and all other required accessories like limit
switches, panel, power supply system (Fastoon
cable type), fasteners, epoxy painting, etc. and
tested to 25 % over load complete as per
specifications.Note: Minimum as specified
capacity or higher as per requirement such that
EOT crane capacity is min.1.25 times of the pump,
motor OR single heaviest component to be lifted
within pump house.Capacity : 2 Ton. (for Pump
Room)Lift : 10.00 m (max) (or as per actual site
condition)Span: 9 m-12 m(or as per actual site
condition)Bay length: 30.0 m (max.) (or as per
actual site condition)
10.1.1 Supplying & Fixing SMC Chequered plate having 5 Sq. 4,493.00
10 mm thickness, made out of SMC Confirming to Mtr.
IS 13410 & by Hot press Compression Moulding
technique Suitable cut & fixed with MS Angle
Frame to Fit Trench Widths as per site requirement
approved by engineer incharge.
Provide as per Actual Site Requirements.
11.1.1 CHLORINATION SYSTEM 4 Plant 2,10,642.00
SITC of wall mounted, FRP cabinet type, Vacuum
operated Chlorination plants with required piping,
fitting, valves, safety and testing kit, etc. Complete
arrangement shall be as per attached standard
drawing for one complete system combaining the
Two plants complete in all respect as per IS and as
per specsification(Without Chlorine
Cylinder).Capacity: 5 kg/hr. for each plant making
one complete plant as per attached standard
drawing and shall include the followings:(1) 1 No.
Submersible Pump motor set with continuous
Cable from pump to starter panel without any Joint
with proper conduit piping and clamping. (2) 1 No.
Diffusers, (3) 1 No. Ejector, (4) 1 No Chlorinator
(5) 1 No. Vacuum Regulators, (6) 1 No. Strainer
(7) 5 Nos. Isolation Ball Valves , (8) 1 Non Return
Valve, (9) 2 Nos. Yoke clamp (for cylinder), (10)
No. Pressure Gauge with require piping and
isolation valve, (11) 1 No. Chlorine Gauge at Cl2
manifold (12) 1 Lot of piping, fittings, valves &
instruments, (13) Vaccum Gauge , 14) MS support
of 50 mm x 50 mm x 4 mm thk, (15) 3C copper
armour power cable from PMCC panel to Chlorine
room of required size with proper piping &
Clamping as required. (16) 1- lot inter connecting
piping of identical pipe size of Cl2 booster pumps
delivery line with isolation valve. (17) 1 No.
common Starter panel with TPNB MCB with
necessary cabling & electrical connections etc. and
other necessary items as per IS & Tender
Specification and Data sheet for Cl2 booster
pumps,(18) 1 no common 3/4" Cl2 gas manifold of
Carbon steel suitable for two cylinder.(Note:-2
Nos. For Ghatlodia Vidhata WDS or As per
instruction of E-I-C.)
11.1.2 Supply of safety kit & testing as specified in the 2 Set 83,241.00
specifications.
(1) 1 Set Chloroscope
(2) 1 set. Air breathing apparatus for 45 min as per
IS with O2 bottle,
(3) 1 set. Emergency tool kit
(4) 1 No. Amonia Torch
(Note:-One Set. For Ghatlodia Vidhata WDS or
As per instruction of E-I-C)
11.1.3 AUTO SHUT OFF CHLORINE CYLINDER 2 Set 9,34,500.00
SITC of Automatic Chlorine cylinder shut off valve
for single chlorine cylinder (100 kg) for
chlorination system comprising of :
(1) 1 No. Pneumatic Auto shut off chlorine cylinder
route valve with actuator system with Air line filter,
Solenoid Valve, Air motor, Yoke clamp, etc. of
required capacity , size, rating
(2) 1 Lot, Control panel cum PLC with
interconnecting cables/wiring for Auto Shutt Off
chlorine Valve of Cylinder,
(3) 1 No, Air Compressor
(4) 1 Lot, uPVC-SCH 40, Air piping for Auto Shut
off valve as required,
(5)1 No Chlorine leak detector of 0-10 ppm
(6) 1 Lot, Interconnecting instrument & Power
(7) 1 No. Industrial Hooter,
(Note:-One Set. For Ghatlodia Vidhata WDS or
As per instruction of E-I-C.)
11.1.4 AUTOMATIC LEAK CHLORINE 2 Set 8,29,500.00
DISSOLVING SYSTEM
SITC of automatic leak chlorine dissolving system
in caustic neutralisation tank for (100 kg) cylinder
for chlorination system comprising of :01) 2 Nos.
FRP Hood for 100 kg Cl2 Cylinder02) 1 no CF Air
Blower03) 1 Lot Flex. PVC ducting Pipe,04) 1 No.
uPVC SCH 40- Diffuser,05) 1 No. Relay based
Control Panel06) 1 Lot Cable and Cable Tray for
Blower07) 1 No. PP + FRP Tank for Caustic
storage08) 1 Lot PP Isolation Ball Valve for Tank
Overflow/Drain09) 1 Lot Hadware, jointing &
misc. items as required to complete the work in all
respects & Civil Foundation.(Note:-One Set For
Ghatlodia Vidhata WDS or As per instruction of
11.1.5 TRAY FOR CHLORINE SOLUTION uPVC 300 RMT 420.00
Providing & Fixing approved make Perforated C
type tray made from CR sheet along with required
accessories to sustain the weight of uPVC pipe with
bends, tees and clamps for fixing of uPVC pipe and
all the fittings as required as per site condition. The
Perorated type tray shall be single or double needed
as per required and as per IS 2062/1079 and shall
be coated with hot deep galvanised as per IS
2629/4759 with coupler plate/Fish plate and GI
hardware like nut-bolt and washers, etc. erected
providing support as per specification and as per
instruction of E-I-C.
Size: 100 x 50 x 1.6 mm thk
(Note:- 150 Mtr or As per Actual Site
Requred.For Ghatlodia Vidhata WDS or As per
instruction of E-I-C.)
12.1.1 DISMANTLING OF EXISTING HSCF PUMP- 1 Job 50,000.00
Dismantling of All Existing Pump-Motor Set of
Existing Pump House covering with Plastic and
packing in Wooden Box with all required
accessories and transportation & stacking at AMC
store / site or As per instruction Given by The
Engineer In-Charge.
12.1.2 DISMANTLING, CARTING AND STACKING 1 Job 30,000.00
(Mechanical Items)
Dismantling of all existing Sluice Valve,
Expansion Bellow, Reduser Pipe on Suction Line
and Sluice Valves, NRV, Expansion Bellow,
Piping On Delivery Line and Drain Pumps, etc. of
Existing HSCF Pump House covering with Plastic
and packing in wooden box with all required
accessories and transportation & stacking at AMC
store / site or as per instruction given by the
engineer In-Charge.
12.1.3 DISMANTLING, CARTING AND STACKING 1 Job 80,000.00
(Electrical Items)
Dismantling of all existing PMCC, APFC Panel,
Cables, Cable Trays, lighting fixtures, existing
lighting wiring, Existing Street Light Poles
including loading, shifting & unloading at location
in plant compound as directed by Enng. in charge
TOTAL ESTIMATE OF MECHANICAL WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev ADB of North West
Work Zone of AMC.
INSTRUMENTATION WORK
ITEM QTY UNIT RATE (in
1.1.1 PRESSURE MEASURING SYSTEM 4 Nos. 1,412.00
Supply, installation, testing & commissioning of
Bourden type Pressure Gauge glycerene filled having
150 mm dial with necessary fittings/accessories
(Manifold valve, nipples, etc. shall be in SS 316 only)
as per specifications & complete in all respects.
Range:0-6kg/sq.cm.
(On Delivery Pipe -Each HSCF Pump Set.)
1.1.2 Supply, installation, testing and commissioning of 4 Nos. 29,147.00
Digital Pressure Transmitter along with, manifold
valve, required fittings, tubing (all valves, fittings,
tubings, etc. shall be in SS 316 only) all accessories,
hardware, etc. complete in all respects as per
specifications and having following measurement
Range:0-6Kg/cm²
(On delivery Pipe- Each HSCF Pump Set. )
2.1.1 LEVEL MEASURING SYSTEM 1 Nos. 59,436.00
Supply, installation, testing and commissioning of
Ultrasonic type Level Transmitter along with all
required accessories, hardware, hardware, etc. complete
in all respects with local and remote display
(Microprocessor based indicator with LED / LCD
digital display), as per specification. The scope also
includes providing 4" flanged , puddle pipe approximate
300 mm long including fixing of the same in civil
structure slabe of pump house for mounting of level
Transmitter.The work also include all necessary work
like make hole,repair / modificationin existing slab,
etc.Level Transmitter having following measurement
ranges for liquid (Water) application:
Meas. Range: upto 10 m (at any one compartment of
The Scope also make hole in existiing civil structure and
installl the Level Sensor.
2.1.2 LEVEL MEASURING SYSTEM 1 Nos. 59,436.00
Supply, installation, testing and commissioning of
Ultrasonic type Level Transmitter along with all
required accessories with LED display 8" digit size &
Frame / Panel size min. (320 mm H X 650 mm W X
mm D) or higher with 4-20 mA Input at Pump house to
monitor the level of ESR in Pump house with all
required accessories complete in all respects as per
Meas. Range: upto 10 m For ESR
Note: For ESR Large Display shall be mounted in
2.1.3 Supply, installation, testing and commissioning of 1 Nos. 12,802.00
Float type Level Switch along with 10 mtr. Cable and
WP Junction Box (at wet well for dry run protection of
pumps) complete in all respects and as per
specification.The scope also includes providing 4"
flanged , puddle pipe approximate 300 mm long
including fixing of the same in civil structure slabe of
pump house for mounting of level switch.The work also
include all necessary work like make hole,repair /
modificationin existing slab, etc.Meas. Range: upto 6 m
(at any one compartment of sump for dry run protection
2.1.4 Supply, installation, testing & commissioning of Float 1 Nos. 17,718.00
& Board type level indicator along with all
accessories, hardware, etc.
complete in all respects as per specifications and having
following measurement ranges:
Meas. Range: upto 6 m (at any one compartment of
3.1.1 ELECTRO MAGNETIC FLOW METER 7 Nos. 1,27,851.00
Supply (AMC Store) of remote type Full Bore
Electromagnetic flow meter comprising of IP-68
Sensor, IP-65/66 remote transmitter with 10m cable
between sensor and transmitter,Panel mounted flow
indicator cum Totalizer along with all mounting
accessories, hardware, etc. complete in all respect and
as per specs and shall have following size and
measurement range. The scope also includes necessary
connection with header pipe.
Meter Size : 300 mm
Pipe size: 300 mm
Pipe Material : C.I. / M.S.
3.1.2 As per Item No. 3.1.1 8 Nos. 1,77,670.00
Meter Size : 350 mm
Pipe size: 350 mm
Pipe Material : C.I. / M.S.
3.1.3 As per Item No. 3.1.1 3 Nos. 2,15,321.00
Meter Size : 450 mm
Pipe size: 450 mm
Pipe Material : C.I. / M.S.
4.1.1 HOOKUP WITH EXISTING PLC PANEL 1 Job 70,000.00
Hookup of New Proposed Pump, MFM, PT, LT, Large
Display, MOV,etc. with existing PLC Panel shall be
carried out by success full bidder and AMC shall be
arrange to provide the access in Existing PLC Panel to
succesfull bidder for data hook of Proposed items and
programming in PLC for auto operation of pump as per
instruction of Client/ AMC.
5.1.1 INSTRUMENT CABLE & ACCESSORIES 200 MTR 141.00
'Supply, Laying, Installation, Connection, Termination,
Testing & Commissioning of Instrument Cables, along
with cable glands, lugs, cable trays, required junction
boxes, fittings and accessores as per specs.The unit rate
shall includea. Supply, loading & unloading of the cable
at site from store.B. Shifitng of cable from site store to
place of installation.c. Fixing of cable clamps, brackets,
supports, route markers etc. where ever required to fix
the cables safely.d. Excavation, back filling and
levelling of ground alongwith laying of fine sand,
protection bricks and other necessary civil material for
laying cables outside the building.e Testing and
submission of sketches & reports of all the cables
laid.POWER CABLE3C x 1.5sq.mm.Cable Length is
Approx. Provide as per Actual Site Requirements.
5.1.2 CONTROL CABLE 100 MTR 128.00
Cable Length is Approx. Provide as per Actual Site
5.1.3 CONTROL CABLE 50 MTR 410.00
5.1.4 SIGNAL CABLE 500 MTR 150.00
Cable Length is Approx. Provide as per Actual Site
5.2.1 INSTRUMENT CABLE TRAY 50 MTR 302.00
GI Perorated type cable tray shall be made out of
galvanized MS sheets of 2.0 mm thickness with
required asccessories . All material shall be Hot dip
galvanised (816 g/m2) as per IS 2629 as mentioned in
specification and tray hardware shall be in GI.
50 x 50 mm - Perforated type
Cable Length is Approx. Provide as per Actual Site
5.3.1 CABLE END TERMINATION AND 10 Nos. 57.00
CONNECTION 'Supply, fixing, connection, testing
and commissioning of double compression brass cable
glands and crimping type Bimetalic lugs / sockets with
necessary tools and equipments as specified in
specifications and IS complete in all respects. The
glands and lugs / sockets shall be suitable for cable size
and type mentioned above. The job also includes
earthing the glands and armour of the cable with
common earth bar or flexible copper mesh as
5.3.2 CONTROL CABLE 10 Nos. 49.00
5.3.3 CONTROL CABLE 12 Nos. 180.00
5.3.4 SIGNAL CABLE 15 Nos. 41.00
TOTAL ESTIMATE OF INSTRUMENTATION WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev ADB of North
work West Zone of AMC.
ELECTRICAL WORK
SR. QTY UNIT RATE AMOUNT
1.1.1 H.T. INDOOR SWITCH GEAR PANEL: 1 Set 3,71,541.00
'Supply, Installation, Testing and
Commissioning of 11 kV, 500 MVA, 630A,
Indoor, Extensible type, Horizontal draw out,
Motorised spring charging mechanism,1
breaker Vacuum Circuit Breaker Panel (1
No. Incomer cum outgoing), with EC grade
copper busbars along with required Resin cast
CT Dual primary & secondary, Cl: 0.5/5P10,
15VA, Digital MFM with RS 485 with 3 Line
Display, Class-0.5s and PT (dual secondary)
Cl:0.5/3P, min 200VA or higher for metering
and protection, 110V DC power pack for
individual incoming and outgoing feeder,
Annunciator, Space heater with Indication
lamp, Hooter, Indicating lamps, Numerical
Protection relay (Current & Voltage Based)
with RS 485 with combined protection for
3O/C+1E/F, S/C, Under & Over Voltage, Tfr.
Protection Aux. relay etc. High speed tripping
relay, Trip ckt supervision relay, Fuse failure
relay, Digital Power factor meter, Ammeter,
Voltmeter (Only I/C), A/M switch suitable for
PLC/SCADA etc. complete in all respects as
per IS, Specification.
1.2.1 H.V. CABLES 50 Mtr 1,261.00
Supply, laying, testing & commissioning of
kV, 3C x 240 sq.mm.XLPE (UE) armoured
H.V Cable stranded Aluminium conductor,
galvanised steel flat strip/ round wire
armoured, extruded PVC type ST2 sheathed,
heavy duty cable conforming to IS:7098 (Part-
2) & IEC:60502(Part-2).
1.3.1 Supply, Installation, Testing and 3 Nos. 6,985.00
Commissioning of the Heat shrinkable type
Indoor H.T.cable end terminations suitable
for 11 kV, 3C x 240 sq.mm. XLPE (UE)
armoured cable including necessary earth
connectivity connection, material &
consummables making the termination/ joint
complete ensuring the joint resistance is within
the permissble limit as per IS.
1.3.2 Supply, Installation, Testing and 1 Nos. 11,487.00
Commissioning of the Heat shrinkable type
outdoor H.T.cable end terminations suitable
for 11 kV, 3C x 240 sq.mm. XLPE (UE)
armoured cable including necessary earth
connectivity connection, material &
consummables making the termination/ joint
complete ensuring the joint resistance is within
the permissble limit as per IS.
2.1.1 DISTRIBUTION TRANSFORMER 1 No 16,06,500.00
SITC of Outdoor type, Three phase, oil
immerged, 11 / 0.433 KV, Energy Efficiency
Level -2, Distribution transformer of
KVA & voltage ratio, copper double wound,
vector group - Dyn11, HV delta connected &
LV star connected with neutral brought out
connected to provide separate earthing
terminals, bushing / cable box on HV side and
cable box on LV side suitable for cables or bus
duct as per requirement with standard fittings,
conforming to IS: 1180 (Part-1) / 2021 with
its latest amendment including first fill of
transformer oil & following accessories.(a) Oil
conservator with filling holes with cap and
prismatic oil level gauge, (b) Silica Gel
dehydrating breather charged with silica gel,
(c) Oil drain cum sampling valve with plug, (d)
Oil filter valve, (e) Lifting Eyes / Hooks / Lugs,
(f) Two earthing terminal, (g) Diagram and
rating plate, (h) Air release plug, (i) Explosion
vent with diaphragm, (j) Thermometer pocket,
(k) Four bi-directional plain roller with base
channel with hauling holes, (l) Fixed / Separate
type radiator banks , (m) Off circuit externally
operated tapping switch (For rating <
kVA), (n) 100 mm stem type oil temperature
indicator (For rating < 500 kVA), (o) Bucholtz
relay with shut off valve , (p) 150 mm dial type
oil temperature indicator with Alarm / Trip
contact (For rating ≥ 500 kVA), (q) 150 mm
dial type winding temperature indicator with
Alarm / Tip contact (For rating ≥ 1000 kVA),
(r) Marshalling box (For rating ≥ 500 kVA), (s)
150 mm dia. magnetic type oil gauge (For
rating ≥ 1600 kVA), (t) Inspection cover &
Jacking lugs. With off circuit tap changer as
per standard IS.Maximum Total Losses (kW)
3.1.1 LOW VOLTAGE (LT) PANEL BOARD 1 Nos. 23,32,070.00
SITC of PMCC Panel (50kA),
compartmentalised, floor mounted/ stand
mounted as per site, Extensible on both
ends,suitable for Manual & Auto operation -
Local & through PLC/SCADA operation as per
site conditions complete in all respects as per
Tender SLD / Specification / IS and including
following as minimum:
1) One Nos. FP 400 A Microprocessor MCCB
for I/C with Digital Voltmeter with Voltmeter
Selector Switch, Digital Power Factor Meter,
Digital Ammeter with Ammeter selector
switch, MFM with RS-485, R, Y, B, on, off,
trip Indicating lamps & TNC Switch, ON, E-
STOP, Reset Pushbutton, etc.
2) 400 A TPN Main busbars. (Main &
Auxiliary bus-bars size with current density
3) Four Nos. (2W + 2S) Soft starter for min.
kW Motor or higher as per pump Manufacturer
reco. with suitable derating and with 250 A
TPN Microprocessor MCCB, 150 A AC3 duty
line & Internal / External bypass
contactor,Minimum.Ten channel temperature
scanner with potential free contacts, fast acting
fuse, MFM with RS-485, door display key pad
& digital MPR+SPP with CBCT, on, off, trip
Indicating lamps & ON, E-STOP,
Local/Remote, Auto/ Manual selector switch &
LCS for Pump- MOV Actuator with Indication
& push button etc.
4) Tr. losses comp. fixed capacitor bank with,
Two no. 5 kVAR, One nos. 2 kVAR & One no.
1 kVAR capacitors bank each with capacitor
duty contactor, timer & 'D' curve MCB, etc. for
each transformer.
5)2 No. 250 A TPN microprocessor MCCB
feeder for 1 Nos for APFC Panel Feeder and
Nos for Borewell Feeder.
6) 1 No. 63A TPN MCCB feeders (for PDB -
Auxiliary accessories load)
7) One no. Outdoor lighting LDB feeder with
32ATPN 'C' curve MCB with 32A contactor &
8) 7 nos. 32A 'C' curve MCB feeders (for
Indoor and Outdoor LDB, 1 no. Chlorination
System,1 No. Dewatering Pump & 3 Nos. spare
9) 4 nos. 16A DP MCB feeders (for single
phase supply for 1nos. X'mer marshaling box,
HT Panel & 2 nos.Spare.)
10) 2 Nos. MOV Actuator 16A FP MCB
feeder for Header BF Valve and 1 nos. spare.
11) 3 nos. 400A/5A, Cl.-0.5 metering CT
12) 1nos. 400 A/5A, Cl.-1 CT for 1 no. APFC
13) 2nos. Multiplication relay for dry run
protection of pumps.
3.1.2 AUTOMATIC POWER FACTOR 1 Set 2,53,954.00
CORRECTION (APFC) PANEL :
SITC of 130 kVAR APFC Panel complete in
all respects as per SLD / Specification / IS and
including following as minimum:(1) 320 A FP
Microprocessor MCCB I/C.(2) 11 Steps
Microprocessor APFC Relay with sensitivity
10mA.(5) 1 no. 30 kVAR capacitor bank with
63A 'D' curve MCB & 30 kVAR Capacitor
duty contactor with timer, Auto and Manual
Switch.(6) 3 nos. 20 kVAR capacitor bank with
40A 'D' curve MCB & 20 kVAR Capacitor
duty contactor with timer, Auto and Manual
Switch.(7) 3 nos. 10 kVAR capacitor bank with
20A 'D' curve MCB & 10 kVAR Capacitor
duty contactor with timer, Auto and Manual
Switch.(8) 1 nos. 5 kVAR capacitor bank with
16A 'D' curve MCB & 10 kVAR Capacitor
duty contactor with timer, Auto and Manual
Switch.(9) 2 nos. 2 kVAR capacitor bank with
16A 'D' curve MCB & 10 kVAR Capacitor
duty contactor with timer, Auto and Manual
Switch.(10) 1 nos. 1 kVAR capacitor bank with
16A 'D' curve MCB & 10 kVAR Capacitor
duty contactor with timer, Auto and Manual
Switch.(11) All capacitors shall be Gas Filled
type with dielectric losses ≤ 0.2w/kVAR.
(Suitable for 0.95 or better Correction).
3.2.1 SITC of Lighting Distribution Board (LDB) 2 Nos. 7,494.00
3 Phase 4 Wire TPN, 6 way Prewired LDB
(One each for Indoor & Outdoor Lighting)
Suitable to house :
Incoming: 32A FP, ELMCB (30mA)
Outgoing: 20A SP MCB 'C' curve (9 nos.) &
16A SP MCB 'C' curve (9 nos.)
(At Panel Room)
3.2.2 SITC of Power Distribution Board (PDB) as 1 Nos. 9,869.00
3 Phase 4 Wire TPN, 8 way Pre-wired-MOG /
MOV PDB for Auxiliary accessories Load
power supply (For MOV Pump delivery
valves, valve at Header & for auxiliary load &
Incoming: 63A 4P, MCB 'C' Curve
Outgoing: 10 Nos. 32A 4P MCB 'C' Curve
3.2.3 LOCAL CONTROL STATION 6 Nos. 2,800.00
SITC of Pendant type ON_OFF LCS with
pushbutton set complete with Enclosure,
necessary mounting/ fixing arrangement on
wall / pipe support etc. to be installed near
motors for remote operation, etc. as per IS and
specifications. (including structural steel) (For
4 nos. HSCF Pump, 2 no. Chlorine Booster
3.2.4 SITC of Local Control Station with pendant 4 Nos. 4,500.00
type Open_Stop_Close pushbutton set and with
Open, Close, Trip & Local / Remote Indicating
Lamps complete with Enclouser, necessary
mounting/ fixing arrangement on wall / pipe
support etc. to be installed near motors for
remote operation, etc. as per IS and
specifications (including structural steel)
(For Delievery Valve of Each Pumps )
4.1.1 LOW VOLTAGE (LT) CABLES 100 Mtr 622.00
Supply and unloading & delivery at site,
storage & security at site of 1.1 kV,
A2XFY/2XWY XLPE insulated (IS 7098) /
PVC insulated (IS 1554) AL / Cu conductor
cables as per specification & IS. The cable
when laid outside the building shall be laid
underground in excavated trench, as per
specified method and shall be laid in prepared
trench on cable tray when laid inside the
3.5C x 185 sq. mm. A2XFY Cable (2 Runs for
Tr.1 to PMCC Panel)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.2 3.5C x 120 sq. mm. A2XFY Cable (1 Runs for 30 Mtr 423.00
From PMCC Panel to APFC Panel)Cable
Length is Approx. Provide as per Actual Site
4.1.3 3C x 120 sq. mm. A2XFY Cable (1 Runs for 200 Mtr 354.00
PMCC Panel to HSCF Pump-Motor set.)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.4 4C x 6 sq. mm. A2XFY Cable (For WR-DB 300 Mtr 78.00
with TPN MCB at Sump & Pump House,
Outdoor LDB, Indoor LDB, 1nos. MOVPDB)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.5 4C x 10 sq. mm. 2XWY/2XFY Cable (For FP 100 Mtr 295.00
MCCB for 1 nos. PDB)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.6 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For 500 Mtr 81.00
TPN MCB for Chlorination Room, TPN MCB
at PMCC room & Pump house maintenance
floor & Pump House floor, Chlorination
system, Motor Operated Valves,)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.7 3C x 2.5 sq. mm. 2XWY/2XFY Cable (For 50 Mtr 86.00
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.8 2C x 2.5 sq. mm. 2XWY/2XFY Cable (For 300 Mtr 177.00
Each Motor space heater(as required), HT
Panel, X'mer marshaling box Single Phase
Supply, for level switch)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.9 5C x 1.5 sq. mm. 2XWY/2XFY Cable (For 1 200 Mtr 130.00
Nos. Dewatering Motor LCS & 1no. Chlorine
Booster Pump LCS)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.10 7C x 1.5 sq.mm. 2XWY/2XFY Cable (For 150 Mtr 115.00
Each Motor LCS with Ameter)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.11 10C x 1.5 sq.mm. 2XWY/2XFY Cable (2 Run 250 Mtr 230.00
Tr. to HT Panel control cable)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.12 12C x 1.5 sq.mm. 2XWY/2XFY Cable (For 250 Mtr 390.00
Actuator LCS of Each Main Pump and
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.13 10Tride x 1.0 sq.mm. individual triad and 300 Mtr 460.00
overall shielded with aluminum mylar tape
Signal Cable for RTD & BTD of motor (1Run
Motor to S/S Panel)
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.2.1 CABLE END TERMINATION AND 4 Nos. 606.00
SITC of Double compression Weather proof
type Ni-Plated brass cable glands and crimping
type Bimetalic lugs / sockets with necessary
tools and equipments as specified in
specifications and IS.
The glands and lugs / sockets shall be suitable
for cable size and type mentioned below & as
per specificaitons.
1) Earthing the glands and armouring with
earthing clamp and jumper and also connecting
to common earth bar.
2) The job also includes, if necessary, supply &
fixing of extension busbar of same material on
MCCB or panel board terminal / connector to
connect more than one no. of parallel cables or
to connect higher size cable to lower size unit.
The job also includes earthing the glands and
armour of the cable with common earth bar or
flexible copper mesh.(Cable termination qty.
shall be as per site requirement)
3.5C x 185 sq. mm. A2XFY Cable (2 Runs for
Tr. 1 to PMCC Panel)
4.2.2 3.5C x 120sq. mm. A2XFY Cable (1 Runs for 2 Nos. 444.00
From APFC PANEL to PMCC Panel)
4.2.3 3C x 120 sq. mm. A2XFY Cable (1 Runs for 8 Nos. 431.00
Main PMCC Panel to HSCF Pump-Motor)
4.2.4 4C x 6 sq. mm. A2XFY Cable (For WR-DB 8 Nos. 111.00
with TPN MCB at Sump & Pump House,
Outdoor LDB, Indoor LDB, 1nos. MOVPDB)
4.2.5 4C x 10 sq. mm. A2XFY Cable (For TPN MCB 4 Nos. 128.00
for 1 nos. PDB)
4.2.6 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For 20 Nos. 77.00
TPN MCB for Chlorination Room, TPN MCB
at PMCC room & Pump house maintenance
floor & Pump House floor, Chlorination
system, Motor Operated Valves)
4.2.7 3C x 2.5 sq. mm. 2XWY/2XFY Cable (For 60 Nos. 76.00
4.2.8 2C x 2.5 sq. mm. 2XWY/2XFY Cable (For 12 Nos. 75.00
Each Motor space heater(as required), HT
Panel, X'mer marshaling box Single Phase
Supply, for level switch)
4.2.9 5C x 1.5 sq. mm. 2XWY/2XFY Cable (For 1 6 Nos. 150.00
Nos. Dewatering Motor LCS & 1no. Chlorine
Booster Pump LCS)
4.2.10 7C x 1.5 sq.mm. 2XWY/2XFY Cable (For 8 Nos. 75.00
Each Delivery and Header LCS with Ameter)
4.2.11 10C x 1.5 sq.mm. 2XWY/2XFY Cable (2Run 8 Nos. 185.00
Tr. 1 to HT Panel control cable)
4.2.12 12C x 1.5 sq.mm. 2XWY/2XFY Cable (For 8 Nos. 105.00
Actuator LCS of Each Main Pump and
4.2.13 10Tride x 1.0 sq.mm. individual triad and 6 Nos. 185.00
overall shielded with aluminum mylar tape
Signal Cable for RTD & BTD of motor (1Run
Motor to S/S Panel)
5.1.1 CABLE TRAY 300 Mtr. 402.00
SITC of GI ladder type cable trays with side
channels of size - 75 x 15 x 15 mm/ 100 x 15 x
15 mm & rungs of size - 35 x15 x 15 mm
spaced at 250 mm apart, fabricated from 2 mm
thick sheet steel in standard length of 2.5 meter,
duly hot dipped galvanized after fabrication as
per IS 2629- 1989/ IS 4759-1984 including
accessories such as coupler plates/ fish plates,
bends, tees, reducers, elbows, covers and
electro- galvanized hardware etc, erected on
existing support as per specification and
instruction of engineer in charge.
150 mm (W) x 100 mm (H) - Ladder type (
Tray RMT is Approx. Provide as per Actual
Site Requirements.)
5.1.2 300 mm (W) x 100 mm (H) - Ladder type ( 200 Mtr 456.00
Tray RMT is Approx. Provide as per Actual
Site Requirements.)
5.2.1 Supply & laying GI perforated type cable 200 Mtr. 228.00
trays with returned edge/ flange, fabricated
from 2.0 mm thk sheet steel in the standard
length of 2.5 mtrs, duly hot dipped galvanized
after fabrication as per IS 2629-1989 / IS 4759-
1984 including accessories such as coupler
plates/ fish plates, bends, tees, reducers,
elbows, covers and electro-galvanized
hardware etc, erected on existing support as per
specification and instruction of engineer in
100 x 50 mm x 2.0 mm thick ( Tray RMT is
Approx. Provide as per Actual Site
5.2.2 150 x 50 mm x 2.0 mm thick ( Tray RMT is 200 Mtr 336.00
Approx. Provide as per Actual Site
5.3.1 Cable Trench, Laying & Installation of 20 Mtr 55.00
Cable: Making cable trench in soft soil of
suitable width of 90cms deep for laying cable
all over the run and back filling the same and
making the surface as normal ground as per IS
& Specification. (For laying HT & LT cable in
5.3.2 Cable Covering in Trench: Cable Covering 20 Mtr. 139.00
with second class bricks or cement tiles laid
cover the cable crosswise & also on both side
with covering of 7.5cms. Layer of sand above
& below cable (16 bricks per meter.) as per IS
& Specification. (For HT & LT cable trench)
6.1.1 Supply, laying and erection of 120 mm 100 Mtr 136.00
approved make Double Walled Corrugated
pipes (DWC) of polyethelene (confirming to IS
14930 II) with necessary connecting accessoies
of same material at required depth for laying of
cable below ground / road surface for enclosing
cable and back filling the same to make ground
as per original. (LT cable).
6.1.2 Supply, laying and erection of 90 mm 100 Mtr 95.00
approved make Double Walled Corrugated
pipes (DWC) of polyethelene (confirming to IS
14930 II) with necessary connecting accessoies
of same material at required depth for laying of
cable below ground / road surface for enclosing
cable and back filling the same to make ground
as per original. (For Motor cable )
6.1.3 Supply, laying and erection of 50 mm 20 Mtr 62.00
approved make Double Walled Corrugated
pipes (DWC) of polyethelene (confirming to IS
14930 II) with necessary connecting accessoies
of same material at required depth for laying of
cable below ground / road surface for enclosing
cable and back filling the same to make ground
as per original.
7.1.1 CHEMICAL EARTHING SYSTEM 3 Nos 10,489.00
SITC of Maintenance free chemical earthing
(copper) with earthpit of minimum bore size
dia. 225mm Safe Earthing Electrode consisting
Pipe-in-Pipe Technology as per IS-3043:1987
/Tech spec. made of corrosion free Pipes
having Outer pipe dia of 48 mm having (plating
thickness as per IS) copper plating, Inner
corrosion free Hot dip galvanised (plating
thickness as per IS) pipe dia of 26 mm with
copper flat strip type connection terminal
14mm dia with constant ohmic value
surrounded by highly conductive corrosion
resistant chemical compound with high charge
dissipation suitable for electrical installation &
of 3Mtr. length of Pipe with two nos. 25Kg. bag
of Back filling compound.
NOTE: Earthing Resistance value & date shall
be painted on the chamber cover.
(2 nos.neutral of Tr.-1, HT Panel )
7.1.2 SITC of chemical earthing with earthpit of 9 Nos 7,025.00
minimum bore size dia. 225 mm Safe Earthing
Electrode consisting Pipe-in-Pipe Technology
as per IS-3043:1987 made of corrosion free
G.I. Pipes having Outer pipe dia of 80 mm
having 80-200 Micron galvanising, Inner pipe
dia of 40 mm having 200-250 Micron
galvanising or copper coated solid steel road /
flat strip type connection terminal 14mm dia
with constant ohmic value surrounded by
highly conductive corrosion resistant chemical
compound with high charge dissipation
suitable for electrical installation of 11 kV &
440V of 2 Mtr. length of Pipe with one no.
25Kg. bag of Back filling compound.
(2nos. Each for body of Tr.1, PMCC And
Motor and other Electrical Accesories )
7.1.3 SITC of 50mm(w) x 6mm(T) etc. sizes as 115 Kg 77.00
required, HOT deep GI Strip including
supply & fixing using GI spacers, saddles
when laid inside the building and inclusive of
excavation & refilling of earth when laid
outside the building & interconnection with
earth pit & all electro-mechanical equipments.
(50X6 G.I Strip wt.2.3 kg/m, 2.3x50Mt.=kg.)
( Transformer, LT Panel and HT Panel etc.)
7.1.4 Supply, laying and erection of 25 mm(w) x 60 Kg 77.00
6mm(T) etc. sizes as required, HOT dip
galvanized GI Strip including supply &
fixing using GI spacers, saddles when laid
inside the building and inclusive of excavation
& refilling of earth when laid outside the
building & interconnection with earth pit & all
electro-mechanical equipments.
(25X6 G.I Strip wt.0.6 kg/m, 0.6x 100 Mt.=kg.)
7.1.5 Supply, laying and erection of 40mm(w) x 112 Kg 787.00
6mm(T) etc. sizes Copper Strip including
supply & fixing of bolts, saddles when laid
inside the building and inclusive of excavation
& refilling of earth when laid outside the
building & interconnection with earth pit & Tr.
7.1.6 Supply, laying and erection of 40 mm(w) x 6 188 Kg 77.00
mm(T) etc. sizes as required, HOT dip
galvanized GI Strip including supply &
fixing using GI spacers, saddles when laid
inside the building and inclusive of excavation
& refilling of earth when laid outside the
building & interconnection with earth pit & all
electro-mechanical equipments.
(40X6 G.I Strip wt1.88 Kg/m, 1.88 x
7.1.7 SITC of HOT Dip Galvanized iron strip wire 8 21 Kg 77.00
SWG (For LDB, PDB, LCS, etc.)(8 SWG G.I
8.1.1 INTERNAL WIRING 300 Mtr 95.00
SITC of Mains & outlet points wiring with
kV grade FRLS PVC insulated ISI marked
flexible stranded copper conductor wires with
medium class min. 25mm. dia. Rigid PVC
pipe and accessories to be erected concealed
in / to be run on surface / wall / ceiling with
following sizes as mentioned below. The unit
rate wirings shall be with connector, PVC
junction box, wires, holder, ceiling rose, angle
holder, switch, sockets, switch board, brass
chromium / cadmium plated machine screws,
phase and neutral wires, green Earth continuity
wires etc. as required to complete wiring from
LDB panel to the final outlet termination
points. The wiring shall be as per IS:732,
IS:4648 and as per tender specification / IS.
(a) SITC of Mains wiring with 3 wire
sq.mm .as per tender specification & IS
8.1.2 (b) SITC of Mains wiring with 3 wire 2.5 300 Mtr 124.00
sq.mm as per tender specification & IS.
8.1.3 (c) SITC of Mains wiring with 4 wire 1.5 300 Mtr 114.00
sq.mm as per tender specification & IS.
8.1.4 (d) SITC of Mains wiring with 4 wire 2.5 300 Mtr 147.00
sq.mm as per tender specification & IS.
9.1.1 SITC of Point wiring for Light / fan / Bell / 40 Nos. 445.00
Primary Point with 2nos. 1.5 sq. mm & earth
wire of 1.5 sq. mm (green) both are of ISI
marked 1.1 kv grade FRLS PVC insulated
multistrand copper wires, pipe to be erected
concealed in flushed on wall / ceiling,
complete with 6A Tissino Type ISI marked
flush type switch / bell push & accessories
erected on metal / PVC Box covered with 3 mm
thick PC (Polycarbonate) / Acrylic sheet
with necessary lamp holder / ceiling Rose /
H. D. connector as directed with medium class
Rigid PVC pipe & accessories.
9.1.2 SITC of 6A independent Plug with 2 nos. 1.5 7 Nos 310.00
sq.mm Cu. Mains size wiring & earthwire of
1.5 sq.mm (green) both are of .ISI marked
KV Grade FRLS PVC insulated multi strand
copper wiress with medium class rigid pvc
pipe erected with ISI marked 3 / 5 Pin socket
and 6A Modular type switch and accessories
with earth continuity of following type erected
on PVC / Metal box, single mounting base
frame covered with textured/metallic/white
front plate modules erected on / in wall / ceiling
as per pipe erected. with necessary ceiling rose
/ H.D.Connector as directed.
( For HT Room / Pump House / LT Room /
Chlorination Room)
9.1.3 SITC of One 300/380 mm dia. Ex fan 16A 6 Nos 829.00
independent Plug point near Ex. Fan with
2nos. 4 sq.mm Cu. Mains size wiring &
earthwire of 1.5 sq.mm (green) both are of ISI
marked 1.1 KV grade FRLS PVC insulated
multistrand copper wires with medium class
Rigid PVC pipe and accessories to be
erected complete with Modular type switch &
5 pin Plug erected on PVC / Metal box covered
with appropriate front plate modules erected on
/ in wall / ceiling as per pipe erected with
following type of accessories. Plug point shall
be near Ex.Fan.
(For Pump House Room /Chlorination Room)
9.1.4 SITC of 6/16A independent Plug with 2nos. 4 6 Nos 601.00
sq.mm Cu. Mains size wiring & earthwire of
2.5 sq.mm (green) both are of ISI marked
1.1 KV grade FRLS PVC insulated
multistrand copper wires with medium class
Rigid PVC pipe and accessories to be erected
on wall / ceiling, complete with ISI marked 3 /
5 Pin socket and tissino type switch erected
with earth continuity connection erected on
Metal / PVC box covered with 3 mm thick
PC(Polycarbonet) / Acrylic sheet. .
(For HT Room/Chlorination Room / Pump
House/ LT Room)
9.1.5 SITC of Single Phase 20A 3 Pin Metal clad 2 Nos. 845.00
Industrial Type Socket with plug top and 20A
SPMCB, suitable for flush mounting, in
SWG MS box of suitable size and covered with
3 mm thick electrical grade hylam sheet or
eqivalent ISI marked Electrical grade bakelite
sheet and earthing with 2.5 sq.mm insulated
copper wire run inside the conduit including
interconnections etc. complete as required.
( For Pump House/ LT Room)
9.1.6 SITC of 3 watts LED Lamps integral type,cool 2 Nos. 69.00
white with PC diffuser suitable for B22 LAMP
holder.(For Panel room, chlorine room door)
10.1.1 1200 mm sweep ceiling fan, capacitor type, 3 Set 1,581.00
having double ball bearing 450mm down rod,
canopies, shackle, rubber bush, blades,
electronic speed regulator, suitable to operate
on 230V,50Hz AC supply conforming to IS:
374/1979.Fan shall be painted with white
(For LT Panel / HT Room / Torrent Room )
10.2.1 380 mm sweep 1400 R.P.M exhaust fan, 6 Nos. 3,052.00
capacitor type, having double ball bearing,
M.S.blades, mounting frame, forearms,
suitable to operate on 230V,50 HZ AC supply
conforming to IS: 2312.Fan shall be painted
with epoxy grey colour controlled by one 6 A
flush type switch on board and 6A plug point
near Ex. fan. With Bird Net
(For Pump House/ LT Room and Chlorination
11.1.1 LED LIGHT FIXTURES: 30 Nos 530.00
SITC of Indoor wall mounting LED indoor
fittings with LEDs of wattage 0.2 Watt to
Watt assembled on single MCPCB, with
housing used as a heat sink shall be made of
thick sheet Steel conforming to IS: 513/CRCA
polyester powder coated and high U.V. &
corrosion resistance with diffuser and/or
Polycarbonate optics with company
mark/name 120 to 300 V,Power Factor more
than 0.9, THD < 10 %, CCT 4000 K to 6500K,
Uniformity ratio >0.7, Luminaire efficacy>
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80
40 Watt or up to 25% higher wattage Tube
Light with integral / non-integral driver, Surge-
2KV, IP-20, 4 feet, Cat-III
(For Existing Room/ LT Room/ Chlorination
Room/ Pump House)
11.1.2 SITC of Surface/Wall mounted LED Indoor 15 Nos. 6,028.00
Flood light fittings with High power White
LEDs wattage of 1Watt and above assembled
on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses with
company mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95,
THD < 10 %, CCT
Uniformity ratio >0.45, Luminaire efficacy>
85 lumens/watt . LED
driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80
90 Watt Indoor Flood Light (IP-65), Surge -
(for pump house cum Panel room)
11.1.3 SITC of 'B' class galvanised iron pipe 32 mm 15 Nos. 340.00
outside dia 45 cmslong duly welded on 20 cms
x 20 cms x 3 mm thick M.S. base plate, erected
on wall or corner for mounting luminaire with
necessary hardware materials duly painted for
wall mounting indoor flood light fixtures on
Wall of Buildings.
12.1.1 EXTERNAL LED LIGHT FIXTURES & 25 Nos. 6,028.00
SITC of Wall mounted 80W LED Outdoor
Flood Light fittings with High power White
LEDs wattage of 1Watt and above assembled
on single MCPCB, efficiency more than
lm/w and corrosion free High pressure die cast
aluminum housing with smooth finish powder
coated and heat sink extruded aluminium with
diffuser and Polycarbonate optics/ lenses with
company mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95,
THD < 10 %, CCT 5000 K to 5700K,
Uniformity ratio >0.45, Luminaire efficacy>
85 lumens/watt . LED driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80
Flood Light (IP-65), Surge -4KV, 80 watt
(for outside Area Lighting as per instruction
given by the engineer In-Charge.)
12.1.2 SITC of 'B' class galvanised iron pipe 32 25 Nos 340.00
mm outside dia 45 cms long duly welded on
cms x 20 cms x 3 mm thick M.S. base plate,
erected on wall or corner for mounting
luminaire with necessary hardware materials
duly painted for wall mounting indoor &
outdoor flood light fixtures on Wall of
13.1.1 SAFETY ACCESSORIES 4 Nos 8,586.00
SITC of following safety accessories
complete with necessary fixing brackets,
other accessories and tools etc. as required
to complete the job.
Supply & Erecting carbon dioxide (CO2) fire
extinguisher of 6.5 kg capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with
nut & bolts grouted in wall complete.
(For X'mer./ HT Room/ LT Room/ Pump
13.1.2 Supplying stand first AID box with anticeptic 2 Nos. 297.00
cream, medicine for use on wounds due burn,
crepe bandage, guage bandage, medicated
ready to use bandage (Band-aid) adhesive tape
for medicinal user, scissors, anticeptic solution
(Savlon or similar) etc.
(All above contents shall be of standard makes)
(For Pump house / LT Room)
13.1.3 Supply & fixing of printed instruction (First 1 Nos. 129.00
Aid) Chart both in English and Gujarati and
duly framed with front glasses, for treatment of
person suffering from electric shock.
13.1.4 Supplying & fixing of FIRE bucket round 8 Set 212.00
bottom of 9 litres capacity made out of
guage G.I. sheet with extra handle at bottom
duly painted white inside and Red outside with
FIRE mark, filled with dry sand and kept on
stand provided or hung on wall hook.
13.1.5 Supplying and erecting floor mounting stand 1 Nos. 933.00
for keeping four nos. of FIRE buckets
comprising 1500 mm in length, 900 mm height
frame made out of 30mm X 30 mm X 4 mm
angle iron with cross supports for legs, welded
with 4 hooks and duly painted with one coat of
red lead and two coats of approved enamelled
13.1.6 Supply and fixing of 30 W fluorescent lamp 1 Nos. 4,912.00
operated emergency light with maintenance
free battery for 3 hours operation during mains
power failure.LED Portable/Rechargeable
flood light having die - cast aluminium
enclosure designed for maximum thermal
efficiency of 130lm luminous efficiency at
voltage supply between 140-270V AV/12V
DC at operating temperature of -20 degree to
60degree celcius with battery back up 3-4hrs
13.1.7 Supply and laying of Synthetic Insulating Mat 6 Mtr 1,017.00
of Class - B of min. thickness 2.5 mm as per
IS:15652 and with good electrical insulation
property for 11kV/22KV as per site
13.1.8 Supply and laying of Synthetic Insulating Mat 8 Mtr 763.00
of Class - A of min. thickness 2 mm as per
IS:15652 and with good electrical insulation
property for 1.1KV/3.3KV as per site
(for PMCC Panels)
13.1.9 Providing pair of rubber hand gloves ISI make 2 Nos. 212.00
suitable for working on 22 KV supply
14.1.1 MISCELLANEOUS: 500 kg 64.84
Providing, Supply of Structure Steel at site of
work with freight, loading, unloading carting,
etc. including all taxes and duties complete
such as joints, channels, angles, Iron Rails,
ISA/ISMC/ISMB/MS flat, Plates, Chequered
plates (below 10mm thickness) etc. required
for support structure of Elecrto-Mechanical
equipments etc. for support on floor / wall /
beam / brackets etc. as per tender and IS.
14.2.1 Labour Charges for lowering, laying, Fixing 500 kg 11.36
with fabrication various size section of MS
such as joints, channels, angles, Iron Rails,
ISA/ISMC/ISMB/MS flat, Plates, Chequered
plates etc Complete with two coats of red oxide
and two coats of approved colour shade of
epoxy paint as per relevant IS and as per
15.1.1 LIASONING CHARGES FOR 1 Ls 25,000.00
OBTAINING POWER / NOC:
Liasoning Charges for obtaining N.O.C from
Electrical Inspector / Statutory authority for
Power / Ele. Installation. (Fees shall be paid by
tenderer for obtaining N.O.C. from Electrical
Inspector / Statutory authority on behalf of
client and shall be reimbursed on submission of
orignial receipt to Client). Liasoning Charges
shall include preparing required attasted
documents & drawing for obtaining NOC on
behalf of client (Applicable Fees / deposits
shall be reimburse by Client).
TOTAL ESTIMATE OF ELECTRICAL WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev ADB of North West
Work Zone of AMC.
SR. NO. ITEM QTY UNIT AMOUNT
Demolition of Brick work & stone masonry including
stacking of serviceable materials and disposal of
unserviceable materials with all lead and lift. (i) In cement
Demolition and disposal of unserviceable materials with all
lead and lift.(i) Unreinforced cement concrete
Demolition and disposal of stacking of serviceable
3 materials and disposal of unserviceable materials with all 10.00 1047.380 Cmt
lead and lift (i) R.C.C work
Clearing and grubbing road land including uprooting rank
vegetation grass bushes,shrubs,sapling and trees girth up to
4 300 mm removal of stumps of trees cut earlier and disposal 1.00 79449.300 Hectare
of unserviceable materials (C) By mechanical means in
area of light jungle
Dismentling doors, windows, ventilators etc. (wood or
steel) shutters including chowkhats architraves, holdfasts
and other attachment etc. complete and stacking them
within all lead and lift.(i) Not exceeding 3 Sq.M. in area.
Dismentling doors, windows, ventilators etc. (wood or
steel) shutters including chowkhats architraves, holdfasts
and other attachment etc. complete and stacking them
within all lead and lift.(ii) Exceeding 3 Sq.M. in area.
Dismentling barbed wire in fencing including making rolls
and also including dismentling fencing posts including all
earth work concrete in base and making good the disturbed
ground stacking useful materials as directed and disposing
as directed and disposing of the unserviceable materials
with all lead and lift.
Removing and scraping of old deteriorated plaster of any
thickness from all Structural & Non Structural member
including stacking of serviceable material and disposal of
unserviceable from site of work with all lead and lift
Supplying Electric breakar machine for RCC slab or
Asphalt demolishing work on site by using operator, fuel,
power supply etc. complete as directed.(no payment should
be allowed for non working condition of machinary and for
pipeline excavation and M.H. work.allowed only for break
down work)(based on previously approved rate by CE Sir)
Boring holes 3.5 m deep in ordinary soil (for cast in situ
piles) and getting out the soil and disposal of the surplus
excavated soil as directed within a lead of 50 Meter for
following diameter of pipes.(iii) 300 mm
Add to or deduct from the rate for Bore Holes of 3.5 m
11 Depth, if bore holes are made deeper or shallower than 1.00 539.340 Each
3.5M. for Piles of following diameter.(iii) 300 mm
Providing and Laying of Rubber Moulded Paver Block
Grey/Coloured 60 mm thick, M-35 Grade of any size ;
shape (Usually Uni-Paver Blocks) using black trap good
quality aggregate of 20 mm nominal size for footpath,
parking areas, service lanes and other areas as mentioned
in the drawing / instruction of engineer in charge. Cost
includes formworks using rubber mould, Rate providing
and laying paver blocks as per required grading and
specification. The paver block shall be mechanically
12 compacted. The work of paving blocks shall be executed in 395.00 383.040 Sq.mt
line and level by skill mason of flooring work only. It
should be laid in such a way that the no cutting of the paver
block to be necessary. If cutting of paver block necessary
then it should be cut by machine only and carting. The
finished surface of the paver block shall have reasonably
good, plain finished. Paver blocks shall be compacted and
shall be relaid if necessary. Gravel or such type of materials
shall not be allowed for production. Laying on 5 cms thick
Supplying and fixing of 300 mm-L x 150 mm-B x 380 mm-
H Kerb block for Footpath in M-20 grade using 20 mm
nominal size black trap aggregate of Sevaliya/Timba or
equivalent quality for pre-cast blocks, reasonably exposed
finish/ formwork , mould with well equipped with vibratory
system for kerb stones of approved design including curing,
etc. complete, including the cost of formwork etc.
complete. The rate shall also include necessary cutting of
asphalt, fixing the Kerb stones in line and level on 5 cm -
13 thick sand bedding with necessary equipments and
materials. The rate shall also include the flush pointing in
CM (1:3) for all joints of the kerbstones. Filling of zari
alone the sides of the kerb stone fixed with Bituminous
concrete Bituminous concrete / C.C. mixed in proper
position to flush with the road surface as directed by
Engineer in change to form a portable mixture.
Laying on 5 Cms thick sand Bedding
Laying on 5 Cms thick sand Bedding 55.00 350.890 Rmt
Removing any kind of pavement incl stacking of serviceble
14 material disposal of unserviceble material with 50 meter 10.00 14.000 Smt
Labour work for fixing above interlocking blocks on up to
50mm th sand bedding, levelling, watering and fixing. Rate
15 incl. average 30cm depth for excavation and or filling, 10.00 68.64 Smt
carting away debries/excavated material up to 5 km and
cleaning the site etc. Comp. as directed.
Excavation for foundation for loose and soft soil including
sorting out and stacking of useful materials and disposing
of the excavated stuff up to 50 meter lead.
Conveyance charge of earth, lime, murrum, building
17 rubbish, manual garbage, sludge, excavated rock, fly ash, 40.00 326.730 Cu.m.
aggregate of any kind etc. Upto 5.0 Km lead.
Conveyance charge of earth, lime, murrum, building
18 rubbish, manual garbage, sludge, excavated rock, fly ash, 10.00 334.140 Cu.m.
aggregate of any kind etc. 5Km to 10 Km lead.
Filling with available excavated earth (excluding rock) in
trenches, plinth, sides of foundation in layers not exceeding
20 cm in depth consolidating each deposited layer by
ramming and watering.
Providing and casting in situ C.C. in grade M-15 (approx.
corresp. to prop. 1:2:4) (proportions as per mix design or as
per Table 9 of IS456 2000 in masses by weigh batching )
using granite, quartzite trap metal of size 6 mm to 20 mm
20 for RCC work, including scaffolding centering, form work, 10.00 4906.000 Cu.m.
needle vibrated consolidation, curing comp. (excluding
cost of reinforcement and neat finishing) with centering and
shuttering/deshuttering etc. comp. for structure for other
than water retaining. Footing (with form work)
Providing and casting in situ C.C. in grade M-15 (approx.
corresp. to prop. 1:2:4) (proportions as per mix design or as
per Table 9 of IS456 2000 in masses by weigh batching )
using granite, quartzite trap metal of size 6 mm to 20 mm
for RCC work, including scaffolding centering, form
work, needle vibrated consolidation, curing comp.
(excluding cost of reinforcement and neat finishing) with
centering and shuttering/deshuttering etc. comp. for
structure for other than water retaining. Footing (without
Providing and cast in situ C.C. in grade M-20( proportions
as per mix design or as per table of IS456 2000 in masses
by weigh batching) using granite, quartzite trap metal of
size 6 mm to 20 mm for RCC Work including scaffolding
centering formwork, needle vibrated consolidation, curing -
complete up to 6 meter depth or height (excluding cost of
reinforcement and neat finishing) with centering and
shuttering/ deshuttering etc. complete for structure other
22 than water retaiing
A) RCC Footing 15.00 5520.000 Cu.m.
B) RCC column 5.00 7363.000 Cu.m.
C) RCC Beam 5.00 6722.000 Cu.m.
D) RCC Coping 5.00 6722.000 Cu.m.
E) RCC Slab 5.00 6504.000 Cu.m.
F) RCC Wall 10.00 6779.000 Cu.m.
Supply cutting, Bending, Binding and placing in position
steel as per plan and design and as per ISS 2502 including
cost of steel and binding wire for reservoirs/ structures only
23 including lift up to 6 meter height or depth below G.L. for 5.00 77504.000 MT
Deformed(TMT)bars confirming to relevant IS Fe-500
grade for all diameters.
Brick work using common burnt clay building bricks
having crushing strength not less than 35kg / Sq. C. M. in
ramp, steps and Foundation & Plinth in cement morter1:5
(1 cement : 5 coarse sand) including racking out joints,
curing, scaffolding required if any etc. complete, as
directed. (B) Conventional
Brick masonry in cement mortar (1:5) using common burnt
clay building bricks having crushing strength not less than
35kg/cm2 including scaffolding,curing, etc. complete for
walls, parapets, etc. at all levels
20 mm thick sand faced cement plaster on walls upto height
10 metres above ground level consisting of 12mm thick
26 backing coat of C.M. 1:3 (1-cement : 3-sand) and 8 mm 105.00 297.680 Sq.mt
thick finishing coat of C.M. 1:1 (1-cement : 1 sand) etc.
Providing and applying 15 mm thick cement plaster in
single coat on brick work with floating coat of net cement
slurry for interior plastering of pumphouse and outside
27 plastering of sump upto finished even and smooth in 315.00 222.56 Sq.mt
Cement motar 1 : 3 (1 cement : 3 sand) including racking
out joint curing, scaffolding required if any, with necessary
cement finishing etc. complete as directed
Interior plain faced 15 mm thick cement plaster (1:3) with
floating coat of neat cement slurry on Underneath Ceiling
of top of UG tank where specified on drawings and or
engineer in charge at all levels including scaffolding,
curing, etc. complete. This rate shall include moulding
where specified.
Writing letter or figures on any surface with black japan Per
paint (stops, comas, hyphens and the like not to be Letter
measured and paid for separately) (i) Block Per
(Letters/Figures) (Per 10 Letter pet CM.HT) Cm/Ht
Providing throating or plaster strip / ghishi and moulding
as instructed by Engineer in charge
Providing in line level plumb, fabricating and fixing three
row horizontal barbed wire fencing and punched tape
concertina coil of 9 turns per meter of 610 mm diameter
fixied with clips on top of the angle iron posts. The punched
tape concertina coil having sharp barbs at every 25 mm
spacing shall be 0.5 mm thick and 19 mm width and
weighting 13 Kg./100 mtr. (Average) as per manufacture's
specification. The rate shall also include providing and
fixed 1.20 mt. total long MS angle 40 x 40 x 6 mm @
mt. c/c spacing embedded in RCC column, angle posts shall
be painted with one coats of red oxide and two coats of
enamel paint of approved quality at top of compound wall.
Fabricating and fixing in position MS structural section
such as flat, pipes, plates, hold fast, anchoring bolts / bars
of required size including fixing, welding and two coats of
approved anti corrosive paint over prime coat of red-oxide
including RCC gate column as per drawing etc. complete
as directed by Engineer-in-charge.
2.2 m height and 6 m wide main , wicket gate and Toilet
White washing with lime on wall surface (two coats) to
give an even shade including thoroughly booming the
surface to remove all dirt, dust; mortar drops and other
Providing and laying broken Chine Mosaic flooring for
terrace using 12 mm to 20 mm broken pieces of glazed tiles
to be laid over Cement mortar 1:3 to plain or slope and to
34 be tempered to bring mortar crème out upto surface using 20.00 739.89 Sq.mt
white cement including rounding of junctions and
extending them upto 15 cm. along the wall, clearing with
water and oxalic acid etc. as directed.
Distempering (two coats) with oil bound distemper of
approved brand and manufacture and of required shade on
undecorated wall surface to give an even shade, over and
including a priming coat with distemper primer of approved
brand and manufacturer after thoroughly brushing the
surface free from mortar dropping and other foreign matter
also including preparing the surface even and sand papered
Applying two coats of Birla(white cement based) or Asian
(acryliclapy putty) or equivalent & two coats of primer of
approved brand and manufacture on new wall surface to
give an even shade including thoroughly brushing the
surface free from mortar dropping and other foreign matte
rand sand papered smooth
Finishing wall with weather proof exterior emulsion paint
on wall surface (two coats) to give an required shape even
37 shade after thoroughly brushing the surface to remove all 113.40 Sq.mt
dirt and remains of loose powdered materials. Etc.
Providing and fixing standared extruded of alluminimum
section of size 63mm x 38.10mm x 1.2mm (Jindal Section
38 : 2434, @ Wt. 0.643 Kg/mt.) with colour powder coated 11.34 1,163.92 Sq.m
alluminium frame for ventilation with 5 mm thick frosted
glass as details etc complete for Ventilation'
Providing and fixing wsh down watercloset
(Europeantype,W.C.Pan) with integral Por S trap including
jointing the trap with soil pipei n Cement Mortar1:1(1-
Cement:1-fine sand) (Seal and cover to beme asured and
paid for separately) (A)vitreous China Pattern :(i) in white
32 dia. C. P. brass half turn flush cock complete including
earthwork, bed concrete of 1:4:8
Providing and fixing flat back white colour vitreous china
wash basin 550 mm x 400 mm size with CI brackets painted
white. Wash basin shall have 15 mm dia GI supply pipe,
overflow chase, 15 mm dia pillar cock and stop cock with
PVC bottle trap and PVC pipe piece upto wall plus 32 mm
dia PVC waste pipe upto floor level connected to 32 mm
dia CI pipe below floor and connected to nearby floor trap
complete with unions and plumber's white soldered joints
with necessary cleaning eye, complete. All chases cut in
wall for fixing pipes shall be made good in CM (1:4).
Providing and fixing Flat Back Urinal ( Hindware-
44cmx31.5cmx26.5cm) or equivalent approved and of
approved shade including fixing the same in concealed CI
41 brackets, CP spreader, CP dome shaped waste coupling, CP 1.00 1,535.63 No
bottle trap with flanges, CP angle cock flush pipe making
inlet and out let connections all complete as per the
instruction of Engineer - In - Charge
Providing, laying and jointing in true line and level
U.P.V.C. Pipe (SCH-40) for including fittings make
PRINCE / SUPREME / ASTRAL / FINOLEX or
equivalent as approved by Engineer In Charge. Pipe shall
be fixed on the wall with the help of clamp at every two -
metre C/C or shall be concelled as directed including
necessary fittings etc. including testing of pipe and joints
and fixing the same with adhesive solvent, including cost
of all materials
Providing & fixing gun metal check or non return full way
Providing and fixing brass screw down stop tap. (A) 15mm
Providing and fixing screw down bib taps of following
size.(C)Gun metal screw down bib tap. i) 15mm dia
Providing and fixing 150 mm x 100 mm intercepting sewer
46 trap embedded in concrete complete including excavation 2.00 976.000 No
and backfilling.
Constructing Manhole with R.C.C. top slab in 1:2:4 mix (1-
cement: 2-coarses and :4- graded stone aggregate 20 mm
nominal size) foundation concrete 1:3:6 mix (1-cement : 3-
coarse sand : 6-Brick bats 40+50 mm size) inside plastering
15 mm thick with Cement Mortar 1:5 (1-Cement : 5-coarse
sand)finished with a floating coat of neat cement and
making channels in cement concrete 1:2:4 mix (1-Cement:
2-Coarses and : 4-stone aggregate 20 mm nominal size)
47 finished smooth complete including curing and festing (i) 1.00 11,314.02 No
Inside size 900mm x 1200 mm and 2.0 M. deep including
C.I. cover with frame size 560mm diameter total weight of
cover and frame to be not less than 128kgs. (Wt. of cover
64Kg. and Wt. of frame 64Kg.) (A) With 230 mm thick
walls of brick msonry using brick having crushing strength
not less than 35Kg./Sq.cm. in Cement Mortar 1:5 (1-
Cement : 5-Coarse sand) (1) A type depth 0.90 Metre for
150 mm diameter sewer.
Providing and fixing in position PVC vent pipes of 160 mm
dia 3 m length.
Providing and fixing cast iron (Spun) Nahni trap of the
following nominal diameter of self cleaning design with
49 C.I. screaed down or hinged grating including cost of 2.00 600.08 No
cutting and making good the walls and floor 100mm inlet
and 50mm outlet. (C) 100mm dia
Providing and fixing S.W. gully trap with C.I. grating brick
masonry chamber and water tight C. I. cover with frame of
300 mm x 300 mm size (inside) with standard weight. (i)
Square mouth traps.(B) 150mm x 100mm size P or R type
Providing and fixing100mm size P or Strap for water closet
squatting pan including jointing the trap with the pan and
soil pipe in cement Mortar1:1 (1-Cement : 1-Fine sand) (A)
52 Providing and laying (to level or slopes) and jointing with 75.00 288.23 Rmt.
stiff mixture of Cement Mortar in proportion 1:1 Selt
glazed stone ware pipes including testing of pipes and
joints complete.(B)150mm dia. (upto 10 ton)
Constructing brick masonry chamber for under ground C.I.
Inspection chamber and bends with bricks having crushing
strength not less than 35Kg.Cm 2in C.M. 1:5 C.I. cover
with frame (Light duty) 455mm x 610mm internal
dimensions total weight of cover with frame to be not less
than 38Kg. (Wt. of cover 23Kg.) and Wt. of frame 15Kg.)
53 (R.C.C. top slab e with 1:2:4 mix (1-cement :2- coarse sand 2.00 3,624.51 No
:4-graded stone aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement mortar 1:3
finished smooth with a floating coat of neat cement on
walls and bed concrete etc. complete. (ii) Inside dimensions
500mmx700mm and 450mm deep for pipe line with one
or two inlets. (upto 10 ton)'
Providing and fixing over roof black colour PVC overhead
54 water tank of approved manufacture with all necessary 3.91 liter
fittings and connection etc,complete on terrace
Providing and fixing 600mm x 450mm bevelled edge
mirror of superior glass mounted on 6mm thick A.C sheet
or plywood sheet and fixed to wooden plugs with C.P
brasss crews (B)600mmx20mm size
Providing and laying white glazed tiles 6 mm thick in
flooring, treads of steps,walls and landing laid on a bed of
56 10 mm thick cement mortar 1:3 (1 cement : 3 coarse sand) 22.42 908.17 Sq.m
finishing with flush pointing in white cement (Upto 10 ton)
In Dedo1.) Floor
Constructing Slab type M.H. Chamber of the following size
including excavation, refilling, brick bats cement concrete
(1:5:10) of thickness 15 C.M., CC Channel (1:2:4) of
thickness 10 C.M., finished 15 mm thick cement plaster
14 inside & outside (Only for shaft) in CM 1:3, finishing
with cement slurry, P/F 4 mm dia M.S.Steel HDPE coated
steps 35 cm c/c at 35 cm staggered in masonary CM 1:5,
57 RCC Slab in CC 1:1.5:3 of thickness 23 C.M., including 3.00 10177.680 No
Cantering & reinforcement (double jalli at 15 C.M. c/c
bothway 12 mm dia.) but excluding the cost of machine
hole seat cover etc..completed. of Size 1.00 X 1.40 meter
(Inside Clear,M.H. length should be parallel to the flow, for
pipe dia <= 800 mm) (Based on Drainage SOR 2009-
10)1.00 to 2.00 meter depth, (Slab at Ground level) for
Rainwater Collection Chamber
Constructing Chamber of following size including
excavation, refilling, BBCC (1:5:10) for foundation,
C.C.Channel (1:2:4), finished 15 mm thick cement plaster
inside in CM 1:3, finishing with cement slurry, Brick
masonary in CM 1:5 & excluding the cost of chamber seat
cover etc..completed. (Based on Drainage SOR 2009-10)
0.60 X 0.45 mt. size Inside Clear, Depth from 0.0 to
0.90meter for pipe dia <=150 mm. chamber for dewatering
Providing & Fixing F.R.C. MH seat cover incl. carting to
the work site etc. comp. Directed. (Based on rate of central
store) FRC medium duty Chamber seat cover (FRC) cover
706 x 556 x 50 mm rectangular cover frame size 600 x
mm clear opening outer size 816 x 666 x 100 mm (MD-10)
cover for dewatering Chamber
Providing F.R.C. MH seat cover incl. carting to the work
site etc. comp. Directed. (Based on rate of central store)
F.R.C. Extra Heavy Duty (EHD-35) machine hole Covers
& Frames Cover : 728mm ø & 100 mm thick circular cover,
35.00 MT load design, 100x2mm MS flat allround, 16mm
60 ø plain round bar for lifting the cover & should be fitted 3.00 2125.000 No
with plastic cups. Frame : 560 mm ø clear opening, outer
size- 888x888x175 mm. On the upper periphery of frame
25 x 3 mm wide MS flat should be well embed in concrete
to protect the edges of frame. FRC E.H.D.-35 machine hole
cover & frame described as above
Making connection to the ex.M.H.in running sewer incl.
Dewatering and other required machinery etc. of following
dia pipes at any convenient time. All damaged work shall
be well repaired as per instructions. etc..complete. (Based
on Drainage SOR 2009-10)
61 connection for dewatering
c) 700 mm to 900 mm dia 2.00 3125.000 No
Kota stone in Jams and Sills of the window and ventilation
62 and Door with one molding as directed by Engineer-in- 35.00 1107.000 Smt
Providing and fixing window having extruded aluminum
Colour anodized section frame main outer size 95mm x
24mm x 1.17 mm (of Jindal Section no : 2459 @ wt. of
0.738 Kg/mt), horizontal Three track member size 92mm x
31.75 mm x 1.30 mm (of Jindal Section no. 8688, @ Wt.
1.07 Kg/mt), vertical member of size 92mm x 31.75mm x
1.50 mm (of Jindal Section no. 8933, @ Wt. 1.06 Kg/mt.)
63 with sliding shutters of horizontal member size 40mm x 25.00 1568.270 Smt
18mm x .29 mm (of Jindal section no. 8947 @ wt.
Kg/mt.) vertical member of size 40mm x 18mm x 1.29mm
(of Jindal Section no. 8949 @ wt. of 0.456 Kg/mt with
mm thick transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures and
transparent silicon sealant glass fixing to frame as per
details etc. PH Window and LT room Windows
Providing and fixing standared extruded of alluminimum
section of size 63mm x 38.10mm x 1.2mm (Jindal Section
64 : 2434, @ Wt. 0.643 Kg/mt.) with colour powder coated 21.60 1163.920 Smt
alluminium frame for ventilation with 5 mm thick frosted
glass as details etc complete for Ventilation
Providing & fixing in position aluminium grill with
micron natural matt brush finish anodised as per over all
size shown on the drawings and aluminium sections of
approved make conforming to IS:733 and IS : 1285, made
out of DG - 104 design ( Jindal or equivivelent ) fixed with
required size F channel, rawl plugs and screws or with
fixing clips, or with expansion hold esters including
65 necessary filling up of gaps at junctions, at top, bottom and 25.00 1750.000 Smt
sides with required PVC/neoprene felt etc. and aluminium
snap beading for glazing / panelling, C. P.brass/stainless
steel screws, including standard anodised aluminium
fittings and fixtures of approved make and of adequate size
and in adequate numbers, including cost and fixing of
fixtures etc. complete as per detailed drawings with all lead
Providing precast cement concrete jali or louvers 40 mm
thick 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone
66 aggregate 6 mm nominal size) reinforced with 1.6 mm dia. 25.00 640.200 Smt
Mild steel wire including roughening, cleaning, fixing and
finishing in CM 1:3 and curing, painting complete
Supplying, fixing Push and Pull, 20 gauge rolling shutter of
approved make for the sizes indicated on drawings
including hood cover, channel sliding assembly, helical coil
67 springs, brackets, interlocking latches, locking 30.00 4277.000 Smt
arrangements, painting with 2 coats of enamel paint over
one coat of approved primer paint etc. complete. Shutters
having width below 3.5M (gear Operated)
Providing and laying cement concrete flooring 1:2:4 (1
cement : 2 coarse sand : 4 graded stone aggregate 20 mm
nominal size) including water proofing compound
68 finishing with a floating of neat cement slurry etc. complete 290.00 348.080 Smt
laid in one layer finished including necessary curing at
bottom of sump.
Average 50 mm thick
Providing and laying polished Kota stone slab flooring over
20 mm (average) thick base of cement mortar 1:6 (1 cement
69 : 6 coarse sand) laid over and jointed with grey cement 290.00 1085.480 Smt
slurry including rubbing and polishing etc. complete at LT
& HT, office room & Chlorine room. 30 mm thick
Providing and laying polished Kota stone slab 25 mm thick
in riser of steps, skirting Dedo & pillars laid on 10 mm thick
70 cement mortar 1:3 (1 cement : 3 coarse sand) and jointed 105.00 1,176.03 Smt
with grey cement slurry including rubbing and polishing
Providing and fixing 40mm dia. GI pipe medium weight
quality as openable type with angle iron support at 1.5 m
c/c using 75 x 75 x 10 mm angles, 1 m long with three rows
71 of pipes as railing including necessary painting with two 55.00 1397.000 Rmt
coats of approved quality oil paint over one coat of
approved primer including necessary welding, bolting
required, if any.
Painting two coats including priming coat on new steel &
other metal surfaces with enamel paint, brushing, interior
to give an even shade including cleaning the surface of
all dirt, dust, other foreign matter.
Providing, Fabricating & fixing WDS name board of Size
3.00mX0.60 made from ISA 50X50X5 mm M.S angle with
3 Nos supports at back side vertical member of angle size
1.1m ht incl 0.3 m hold fast inserted in compound wall with
73 necessary dismantling and fixing with cement concrete. 1.00 15,640.00 No.
The rate shall also incl 16 g M.S sheet of size 3.00X0.60
mt incl ACP Sheet with Printing letter with AMC logo as
directed by EIC. rate shall incl painting board with 2 coat
of enamal paint over one coat of anti-corrosive primer.
Providing, Fabricating & fixing caution board of size
1.50m x 0.60m made from ISA 40 x 40 x 5 mm MS angle
with 2 nos. supports at back side vertical member of of
angle size 1.10m height (inclu. 0.30m hold fast inserted in
compound wall with necessary dis-mantling and fixing
with cement concrete. The rate shall also include 14g MS
sheet of size 1.50mt x 0.60mt incl ACP Sheet with Printing
letter with logo as directed by EIC. rate shall incl painting
board with 2 coat of enamal paint over one coat of anti-
corrosive primer.
Providing and fixing Radium sign board of size 3.00mt x
75 0.60 mt made from ACP sheet with writing coloured 1.00 7,400.00 Nos.
reflected letter of WDS name board with necessary clamp
for hanging board at pump house etc. comp as directed by
Grouting with 1:3 cement, sand mortar for anchor bolt
pockets, machine bases, pipe sleeves, pockets holes, etc.
including roughening and cleaning of concrete surfaces,
curing, etc. complete.
TOTAL ESTIMATE OF CIVIL WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical,
of Electrical, Instrumentation and Civil works for Water Distribution Station At
Work Bodakdev ADB of North West Zone of AMC.
Description Qty. Unit Amount
OFFICE FURNITURE
1 Office Table of size 1200 mm length X 600 1 Nos. 3,000.00
2 Steel Office Chair 3 Nos. 1,000.00
3 Steel Cupboard 1 Nos. 25,000.00
Ladder: Ladder shall be made out of light
aluminium allow of good strength. They
shall be of step ladder, foldable, self
4 supportig type with sperader of metalic 1 Nos. 6,000.00
angles or high strength.
Ladder: As per S.R. No.2.(i) 3 Meter long
Ladder: As per S.R. No.2.(ii) 6 Meter long
GRAND TOTAL OF TOOLS, TEST EQUIPMENTS & SPARE PARTS
GRAND TOTAL OF TOOLS, TEST EQUIPMENTS & SPARE PARTS
Note: Above items shall be handed over to AMC before the commencement of O&M period
for new proposed Water Distribution Station at WDS of AMC.
Name Augmentation work with SITC of Pumping Machinery with related
of Mechanical, Electrical, Instrumentation and Civil works for Water
Work Distribution Station At Bodakdev ADB of North West Zone of AMC.
Item Qty. Unit Rate Amount
1 Existing HSCF Pump Motor set 3 Nos. -
Existing Distribution Transformer -
3 Existing LT Panel. 1 Lot. -
4 Existing APFC Panel 1 Lot. -
5 Existing HT VCB Panel 1 Lot. -
TOTAL OF BUYBACK AMOUNT (In Rs.) -
Notes: The rate of the items shall be deducted from the capital cost of the tender and
contractor shall carryout all items.
AMC will take final decision whether to sell item or not. If AMC does not sell
particular item, the bidder will not get rebate amount of that item.
SUMMARY OF COST
Name Augmentation work with SITC of Pumping Machinery with related Mechanical,
of Electrical, Instrumentation and Civil works for Water Distribution Station At
Work Bodakdev Trilok of North West Zone of AMC.
A. MECHANICAL WORK
B. INSTRUMENTATION WORK
C. ELECTRICAL WORK
TOOLS & TEST EQUIPMENTS
TOTAL AMOUNT OF CAPITAL COST (A + B + C + D + E)
TOTAL AMOUNT OF CAPITAL COST (A + B + C + D + E)
F. (EXCLUDING GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev Trilok of North West
Work Zone of AMC.
MECHANICAL WORK
ITEM QTY UNIT AMOUNT
1.1.1 HORIZONTAL SPLIT CASING 3 Nos. 4,63,830.00
CENTRIFUGAL PUMP WITH MOTOR
Supply, installation, testing and
commissioning of horizontal mounted, side
suction & side delivery type Horizontal Split
Casing Centrifugal Pump having CI Casing,
CF 8 M impeller & wear rings, SS410 Shaft &
shaft sleeves, Mechanical seal and suitable to
couple with TEFC squirrel cage IE3 efficiency
class Induction Motor, 3 Phase, 415 V, 50 Hz.,
AC supply, max. 1500 RPM synchronous
speed. The scope shall also include all required
accessories viz. CI drain rim type base plate,
Flex. coupling, coupling guard, foundation
bolts, min 25 mm dia. G.I. Class-B drain pipe
upto drain channel, etc. as per specification.
Capacity : 400 m³/hr
Motor Rating : 55 KW or as per Manfactuer
The scope also includes chipping, grouting,
altering the civil foundation to suit the new
pumpset as required and removal of debries
and cleaning the dry well.
INDUCTION MOTOR FOR ABOVE
Supply Installation Testing and
Commissioning (SITC) of approved make,
energy efficient, Efficiency Class-IE3,
horizontal foot mounting, solid shaft, squirrel
case, Induction Motor rating mini 55 kW or
higher as per IS, 3-Phase, 415V, 50Hz., AC
supply, maxi.1500 RPM synchronous speed
and having TEFC enclosure with Class F
insulation (temp. rise limited to Class B) with
2.1.1 VALVES 2 Nos. 3,057.00
Supply, Installation, testing and
commissioning of Manually gear operated
CI/DI Double Flanged, Rising Spindle type,
Sluice Valve conforming to IS 14846 PN
with SS 304 seat rings and SS spindle with hot
dipped galvanised hardware's, bolts, nuts &
washers, gaskets, etc. as per data sheet.
Size : 50 mm NB (Manually Operated - On
delivery pipe of Dewatering Pump )
2.2.1 Supply, installation, testing and 3 Nos. 1,45,535.00
commissioning of Electrically gear operated
CI/DI Double Flanged, Rising Spindle type,
Sluice Valve with actuator, integral
starter,etc. conforming to IS 14846 PN
with SS 304 seat rings and SS spindle with all
hot dipped galvanised hardware's, bolts, nuts &
washers, gaskets, etc. as per data sheet.
Size: 250mm NB (Electrically Operated - On
Delivery Pipe )
2.3.1 Supply, installation, testing and 3 Nos. 28,776.00
commissioning of double flanged CI/DI Dual
Plate Check Valve conforming to API
Class 300 / PN 1.6 with CS dual door, hinge
pin & stop pin of SS 410 , springs of AISI
and seat rings of SS 304 ( renewable ), along
with all required accessories, gaskets and
hardwares,etc. and as per specification.
Size : 250 mm NB (On Delivery Pipe)
3.1.1 Supply,Installation,Testin and Commissioning 3 Nos. 10,200.00
of double flanged Expansion Bellows
confirming to EJMA/IS standard with PN
rating & all necessary St.St. hardware's.
Size : 300 mm NBx 300 mm ( L )(On Suction
3.1.2 Size : 250 mm NBx 300 mm ( L )(On Delivery 3 Nos. 7,745.00
4.1.1 SITC of CI flanged reducer/expander 3 Nos. 3,364.00
conforming to IS 1538 with gaskets, hardware
and required accessories as per specifications.
Size: 300 mm X 200 mm X 600 mm (L)
Note:-(Suction Reducer- 200 mm or size as
per Actual HSCF Pump Suction Flange)
(Reducer Length Size shall be as per Actual
Note:- (Delivery Expander- 150 mm or size
as per Actual HSCF Pump Delivery Flange)
(Reducer Length Size shall be as per Actual
5.1.1 Flanged Joints of Pipes, Fittings and 10 Nos. 434.00
Supply, Installation, Making of Flanged CI &
GI Pipes, Fittings and Specials Joints with all
jointing materials, rubber packing, nut bolts,
labour etc.for complete connection.
Size: 50 mm dia
5.1.2 Size: 150 mm dia 4 Nos. 611.00
5.1.3 Size: 200 mm dia 4 Nos. 837.00
5.1.4 Size: 250 mm dia 18 Nos. 1,007.00
5.1.5 Size: 300 mm dia 12 Nos. 1,223.00
6.1.1 M.S. PIPES & SPECIALS 15 RMT 4,834.64
Supply, Gas cutting of pipe, Fabrication,
welding, Installation, testing and
commissioning of MS pipe & Specials
conforming to IS 3589 & flanges confirming
to IS 6392-PN-1.0, fabricated from MS. plate
with necessary supports & anchoring. Pipe
fabricated from MS plate. (Excluding supply
Size: 250 mm NB X 10 mm Thk
6.1.2 Size: 300 mm NB X 10 mm Thk 10 RMT 5,752.05
6.2.1 MS FITTINGS & SPECIALS: 1000 KG 70.67
Supply, Fabrication, Gas cutting of pipe,
welding, Installation, testing and
commissioning of MS flanged / plain ended
specials and fittings like MS reducer,
expander, Metering bends, Tees, etc.
conforming to IS 3589, flanges confirming to
IS 6392-PN- 1.0, fabricated from MS. plate
with necessary supports & anchoring. Pipe
fabricated from MS plate. (Excluding supply
Size: 250 mm NB mm x 10 mm Thk and
Above Dia Size.
The scope also includes civil work, casting
PCC thrust block, chipping, grouting,
supporting,etc. require for laying & connecting
the MS pipes & fittings as require outside the
6.2.2 Size: 300 mm NB mm x 10 mm Thk and 1000 KG 70.67
Above Dia Size.
6.3.1 Providing epoxy coating to inside and outside 12 Sq.m 332.00
pipe line with two parts of Solvent free high
build liquid epoxy lining as per AWWA C210-
07 Suitable for potable water application &
shall be approved by CFTRI- India/BS 6920-
UK/international standard /NSF/ANSI/-61
2004 to be fit for contact with potable water for
human consumption with 406 micron
thickness. inclusive of necessary materials
labour ,Equipment ,Contractor's overhead
charges and profit and including all taxes.Size:
6.3.2 Size 300 mm NB 9 Sq.m 332.00
6.4.1 Supply, welding , Installation, testing & 12 Nos. 3,220.28
commissioning of MS flat machined faced
flanges confirming to IS 6392 & drilled as per
IS-1538 with drilling off centre bolt holes and
flange thickness as per PN 1.0 including
cutting & welding.
Size : 250 mm NB Drilled
6.4.2 Size : 300 mm NB Drilled 6 Nos. 3,930.78
7.1.1 G.I. PIPES & FITTINGS: 15 RMT 387.00
Supply, installation, connection with
equipments as required, testing and
commissioning of GI pipe conforming to IS-
1239 , Medium Duty with coupling, tee,
bend, union, elbow, flanges , etc as all
required fittings for connection complete with
gaskets, hardware, and required accessories
as per IS & Specifications
Size: 50 mm NB(For dwatering Pump)
8.1.1 DEWATERING PUMPS 2 Nos. 1,46,348.00
Supply, erection, testing and commissioning of
Non Clog Submersible Pump with C.I. casing
& CF8M impeller, including necessary
accessories and hadrwares, etc., 25m cable as
required suitable for 3 phase, 415 V, 50 Hz AC
supply with min. 3 HP motor and necessary
safety futures along with pump monitoring unit
for auto stop facilities, cable termination /
juction box of required terminal size,
supporting arrangement for pump and other
required accessories to be installed in dry well
Capacity: 30 m3/hr
Head: 15 m. Motor Rating: Mini. 2.2 kw (or
higher rating as reco. by pump manufacturer)
9.1.1 E.O.T. CRANE WITH HOIST 1 Nos 5,06,250.00
Providing & erecting Single girder type fully
electrically operated E.O.T. crane with
electrically operated hoist, class II duty, geared
travelling trolley with seven meter lift
complete with long travel rail track (40 mm sq.
bar), moving or cross girder, all three motions
electrically operated by suitable rating motor
IP 54, control panel & down pendant control
block, brake, safety device, cables form motor
to starter panel & other required accessories &
tested as per IS Specifications.EOT Crane with
single/Box type girder having motorised
motion in all three directions, manufactured as
per IS - 807, IS 3938 & IS - 3177 , class-II,
complete with electrically operated hoist,
geared trolley, cross girder, rail track, brake,
wire rope drum, motors, safety device, pendant
push button, starter panel, cables from motor
to starter panel and all other required
accessories like limit switches, panel, power
supply system (Fastoon cable type), fasteners,
epoxy painting, etc. and tested to 25 % over
load complete as per specifications.Note:
Minimum as specified capacity or higher as
per requirement such that EOT crane capacity
is min.1.25 times of the pump, motor OR
single heaviest component to be lifted within
Capacity : 2 Ton. (for Pump Room)
Lift : 10.00 m (max) (or as per actual site
Span: 9 m-12 m(or as per actual site condition)
Bay length: 30.0 m (max.) (or as per actual site
10.1.1 Supplying & Fixing SMC Chequered plate 5 Sq. 4,493.00
having 10 mm thickness, made out of SMC Mtr.
Confirming to IS 13410 & by Hot press
Compression Moulding technique Suitable cut
& fixed with MS Angle Frame to Fit Trench
Widths as per site requirement approved by
engineer incharge.
Provide as per Actual Site Requirements.
11.1.1 CHLORINATION SYSTEM 2 Plant 2,10,642.00
SITC of wall mounted, FRP cabinet type,
Vacuum operated Chlorination plants with
required piping, fitting, valves, safety and
testing kit, etc. Complete arrangement shall be
as per attached standard drawing for one
complete system combaining the Two plants
complete in all respect as per IS and as per
(Without Chlorine Cylinder).
Capacity: 5 kg/hr. for each plant making one
complete plant as per attached standard
drawing and shall include the followings:
(1) 1 No. Submersible Pump motor set with
continuous Cable from pump to starter panel
without any Joint with proper conduit piping
and clamping. (2) 1 No. Diffusers, (3) 1 No.
Ejector, (4) 1 No Chlorinator , (5) 1 No.
Vacuum Regulators, (6) 1 No. Strainer , (7)
Nos. Isolation Ball Valves , (8) 1 Non Return
Valve, (9) 2 Nos. Yoke clamp (for cylinder),
(10) 1 No. Pressure Gauge with require piping
and isolation valve, (11) 1 No. Chlorine Gauge
at Cl2 manifold (12) 1 Lot of piping, fittings,
valves & instruments, (13) Vaccum Gauge
14) MS support of 50 mm x 50 mm x 4 mm
thk, (15) 3C copper armour power cable from
PMCC panel to Chlorine room of required size
with proper piping & Clamping as required.
(16) 1- lot inter connecting piping of identical
pipe size of Cl2 booster pumps delivery line
with isolation valve. (17) 1 No. common
Starter panel with TPNB MCB with necessary
cabling & electrical connections etc. and other
necessary items as per IS & Tender
Specification and Data sheet for Cl2 booster
pumps,(18) 1 no common 3/4" Cl2 gas
manifold of Carbon steel suitable for two
12.2.1 Supply of safety kit & testing as specified in 1 Set 83,241.00
the specifications.(1) 1 Set Chloroscope(2)
set. Air breathing apparatus for 45 min as per
IS with O2 bottle,(3) 1 set. Emergency tool
kit(4) 1 No. Amonia Torch
12.3.1 AUTO SHUT OFF CHLORINE 1 Set 9,34,500.00
CYLINDER VALVE SYSTEM
SITC of Automatic Chlorine cylinder shut off
valve for single chlorine cylinder (100 kg) for
chlorination system comprising of :
(1) 1 No. Pneumatic Auto shut off chlorine
cylinder route valve with actuator system with
Air line filter, Solenoid Valve, Air motor,
Yoke clamp, etc. of required capacity , size,
(2) 1 Lot, Control panel cum PLC with
interconnecting cables/wiring for Auto Shutt
Off chlorine Valve of Cylinder,
(3) 1 No, Air Compressor
(4) 1 Lot, uPVC-SCH 40, Air piping for Auto
Shut off valve as required,
(5)1 No Chlorine leak detector of 0-10 ppm
(6) 1 Lot, Interconnecting instrument & Power
(7) 1 No. Industrial Hooter,
12.4.1 AUTOMATIC LEAK CHLORINE 1 Set 8,29,500.00
DISSOLVING SYSTEM
SITC of automatic leak chlorine dissolving
system in caustic neutralisation tank for (100
kg) cylinder for chlorination system
comprising of :
01) 2 Nos. FRP Hood for 100 kg Cl2 Cylinder
02) 1 no CF Air Blower
03) 1 Lot Flex. PVC ducting Pipe,
04) 1 No. uPVC SCH 40- Diffuser,
05) 1 No. Relay based Control Panel
06) 1 Lot Cable and Cable Tray for Blower
07) 1 No. PP + FRP Tank for Caustic storage
08) 1 Lot PP Isolation Ball Valve for Tank
09) 1 Lot Hadware, jointing & misc. items as
required to complete the work in all respects &
Civil Foundation.
12.5.1 TRAY FOR CHLORINE SOLUTION 150 RMT 420.00
Providing & Fixing approved make Perforated
C type tray made from CR sheet along with
required accessories to sustain the weight of
uPVC pipe with bends, tees and clamps for
fixing of uPVC pipe and all the fittings as
required as per site condition. The Perorated
type tray shall be single or double needed as
per required and as per IS 2062/1079 and shall
be coated with hot deep galvanised as per IS
2629/4759 with coupler plate/Fish plate and GI
hardware like nut-bolt and washers, etc.
erected providing support as per specification
and as per instruction of E-I-C.
Size: 100 x 50 x 1.6 mm thk
13.1.1 DISMANTLING OF EXISTING HSCF 1 Job 50,000.00
PUMP-MOTOR SETDismantling of All
Existing Pump-Motor Set of Existing Pump
House covering with Plastic and packing in
Wooden Box with all required accessories and
transportation & stacking at AMC store / site
or As per instruction Given by The Engineer
13.1.2 DISMANTLING, CARTING AND 1 Job 30,000.00
STACKING (Mechanical Items)
Dismantling of all existing Sluice Valve,
Expansion Bellow, Reduser Pipe on Suction
Line and Sluice Valves, NRV, Expansion
Bellow, Piping On Delivery Line and Drain
Pumps, etc. of Existing HSCF Pump House
covering with Plastic and packing in wooden
box with all required accessories and
transportation & stacking at AMC store / site
or as per instruction given by the engineer In-
13.1.3 DISMANTLING, CARTING AND 1 Job 30,000.00
STACKING (Electrical Items)
Dismantling of all existing Cables, Cable
Trays, lighting fixtures, existing lighting
wiring, Existing Street Light Poles including
loading, shifting & unloading at location in
plant compound as directed by Enng. in charge
SUPPLY ITEM AT RAIKHAD AMC STORE
14.1.1 HORIZONTAL SPLIT CASING 3 Nos. 12,36,480.00
CENTRIFUGAL PUMP WITH MOTOR
Supply of horizontal mounted, side suction &
side delivery type Horizontal Split Casing
Centrifugal Pump having CI Casing, CF 8 M
impeller & wear rings, SS410 Shaft & shaft
sleeves, Mechanical seal and suitable to
couple with TEFC squirrel cage IE3 efficiency
class Induction Motor, 3 Phase, 415 V, 50 Hz.,
AC supply, max. 1500 RPM synchronous
speed. The scope shall also include all required
accessories viz. CI drain rim type base plate,
Flex. coupling, coupling guard, foundation
bolts, min 25 mm dia. G.I. Class-B drain pipe
upto drain channel, etc. as per specification.
Capacity : 900 m³/hr
Motor Rating : 160 KW or as per
Manfactuer Standard
The scope also includes chipping, grouting,
altering the civil foundation to suit the new
pumpset as required and removal of debries
and cleaning the dry well.
INDUCTION MOTOR FOR ABOVE
Supply of approved make, energy efficient,
Efficiency Class-IE3, horizontal foot
mounting, solid shaft, squirrel case, Induction
Motor rating mini 160 kW or higher as per IS,
3-Phase, 415V, 50Hz., AC supply, maxi.1500
RPM synchronous speed and having TEFC
enclosure with Class F insulation (temp. rise
limited to Class B) with RTD/BTD.
15.1.1 VALVES 3 Nos. 64,491.00
Supply of Manually gear operated CI/DI
Double Flanged, Rising Spindle type, Sluice
Valve conforming to IS 14846 PN 1.0 with SS
304 seat rings and SS spindle with hot dipped
galvanised hardware's, bolts, nuts & washers,
gaskets, etc. as per data sheet.
Size : 450 mm NB (Manually Operated - On
Suction pipe of HSCF Pump )
15.1.2 Supply of Electrically gear operated CI/DI 3 Nos. 1,77,848.00
Double Flanged, Rising Spindle type, Sluice
Valve with actuator, integral starter,etc.
conforming to IS 14846 PN 1.0 with SS
seat rings and SS spindle with all hot dipped
galvanised hardware's, bolts, nuts & washers,
gaskets, etc. as per data sheet.
Size: 400mm NB (Electrically Operated - On
Delivery Pipe )
15.1.3 Supply of double flanged CI/DI Dual Plate 3 Nos. 83,509.00
Check Valve conforming to API 594 Class
300 / PN 1.6 with CS dual door, hinge pin &
stop pin of SS 410 , springs of AISI 304 and
seat rings of SS 304 ( renewable ), along with
all required accessories, gaskets and
hardwares,etc. and as per specification.
Size : 400 mm NB (On Delivery Pipe)
16.1.1 Supply of double flanged Expansion Bellows 3 Nos. 18,780.00
confirming to EJMA/IS standard with PN
rating & all necessary St.St. hardware's.
Size : 450 mm NBx 300 mm ( L )(On Suction
16.1.2 Size : 400 mm NBx 300 mm ( L )(On Delivery 3 Nos. 16,500.00
17.1.1 Supply of CI flanged reducer/expander 3 Nos. 8,410.00
conforming to IS 1538 with gaskets, hardware
and required accessories as per
specifications.Size: 450 mm X 350 mm X
mm (L) Note:-(Suction Reducer- 350 mm or
size as per Actual HSCF Pump Suction
Note:- (Delivery Expander- 300 mm or size
as per Actual HSCF Pump Delivery Flange)
NOTE: SUPPLY, INSTALLATION, TESTING, AND COMMISSIONING FOR BELOW ITEMS
FOR OTHER WDS LOCATION AS PER INSTRUCTION BY ENGINEER-IN-CHARGE.
18.1.1 HORIZONTAL SPLIT CASING 4 Nos. 12,61,480.00
CENTRIFUGAL PUMP WITH MOTOR
SITC of horizontal mounted, side suction &
side delivery type Horizontal Split Casing
Centrifugal Pump having CI Casing, CF 8 M
impeller & wear rings, SS410 Shaft & shaft
sleeves, Mechanical seal and suitable to
couple with TEFC squirrel cage IE3 efficiency
class Induction Motor, 3 Phase, 415 V, 50 Hz.,
AC supply, max. 1500 RPM synchronous
speed. The scope shall also include all required
accessories viz. CI drain rim type base plate,
Flex. coupling, coupling guard, foundation
bolts, min 25 mm dia. G.I. Class-B drain pipe
upto drain channel, etc. as per specification.
Capacity : 900 m³/hr
Motor Rating : 160 KW or as per
Manfactuer Standard
The scope also includes chipping, grouting,
altering the civil foundation to suit the new
pumpset as required and removal of debries
and cleaning the dry well.
INDUCTION MOTOR FOR ABOVE
SITC of approved make, energy efficient,
Efficiency Class-IE3, horizontal foot
mounting, solid shaft, squirrel case, Induction
Motor rating mini 160 kW or higher as per IS,
3-Phase, 415V, 50Hz., AC supply, maxi.1500
RPM synchronous speed and having TEFC
enclosure with Class F insulation (temp. rise
limited to Class B) with RTD/BTD.
19.1.1 VALVES 4 Nos. 67,251.00
SITC of Manually gear operated CI/DI
Double Flanged, Rising Spindle type, Sluice
Valve conforming to IS 14846 PN 1.0 with SS
304 seat rings and SS spindle with hot dipped
galvanised hardware's, bolts, nuts & washers,
gaskets, etc. as per data sheet.
Size : 450 mm NB (Manually Operated - On
Suction pipe of HSCF Pump )
19.1.2 Supply of Electrically gear operated CI/DI 4 Nos. 1,79,819.00
Double Flanged, Rising Spindle type, Sluice
Valve with actuator, integral starter,etc.
conforming to IS 14846 PN 1.0 with SS
seat rings and SS spindle with all hot dipped
galvanised hardware's, bolts, nuts & washers,
gaskets, etc. as per data sheet.
Size: 400mm NB (Electrically Operated - On
Delivery Pipe )
19.1.3 Supply of double flanged CI/DI Dual Plate 4 Nos. 85,480.00
Check Valve conforming to API 594 Class
300 / PN 1.6 with CS dual door, hinge pin &
stop pin of SS 410 , springs of AISI 304 and
seat rings of SS 304 ( renewable ), along with
all required accessories, gaskets and
hardwares,etc. and as per specification.
Size : 400 mm NB (On Delivery Pipe)
20.1.1 SITC of double flanged Expansion Bellows 4 Nos. 18,780.00
confirming to EJMA/IS standard with PN
rating & all necessary St.St. hardware's.
Size : 450 mm NBx 300 mm ( L )(On Suction
20.1.2 Size : 400 mm NBx 300 mm ( L )(On Delivery 4 Nos. 16,500.00
21.1.1 SITC of CI flanged reducer/expander 4 Nos. 8,410.00
conforming to IS 1538 with gaskets, hardware
and required accessories as per specifications.
Size: 450 mm X 350 mm X 600 mm (L)
Note:-(Suction Reducer- 350 mm or size as
per Actual HSCF Pump Suction Flange)
21.1.2 Size: 400 mm X 300 mm X 600 mm (L)Note:- 4 Nos. 6,960.00
(Delivery Expander- 300 mm or size as per
Actual HSCF Pump Delivery Flange)
22.1.1 DISMANTLING AND RE-INSTALLING 4 Job 75,000.00
OF HSCF PUMP-MOTOR SET
Dismantling of 4 Nos. of HSCF Pump-Motor
Set and Re-Installing with All required
accessories and transportation & stacking
location At other WDS OR As per instruction
Given by The Engineer In-Charge. (Including
Transportation, Testing, Commissionning and
TOTAL ESTIMATE OF MECHANICAL WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev Trilok of North
Work West Zone of AMC.
INSTRUMENTATION WORK
ITEM QTY UNIT RATE AMOUNT
1.1.1 PRESSURE MEASURING SYSTEM 3 Nos. 1,412.00
Supply, installation, testing & commissioning of
Bourden type Pressure Gauge glycerene filled
having 150 mm dial with necessary
fittings/accessories (Manifold valve, nipples,
etc. shall be in SS 316 only) as per specifications
& complete in all respects.
Range:0-6kg/sq.cm.
(On Delivery Pipe -Each HSCF Pump Set.)
1.1.2 Supply, installation, testing and commissioning 3 Nos. 29,147.00
of Digital Pressure Transmitter along with,
manifold valve, required fittings, tubing (all
valves, fittings, tubings, etc. shall be in SS
only) all accessories, hardware, etc. complete in
all respects as per specifications and having
following measurement ranges:
Range:0-6Kg/cm²
(On delivery Pipe- Each HSCF Pump Set. )
2.1.1 LEVEL MEASURING SYSTEM 1 Nos. 59,436.00
Supply, installation, testing and commissioning
of Ultrasonic type Level Transmitter along with
all required accessories, hardware, hardware,
etc. complete in all respects with local and
remote display (Microprocessor based indicator
with LED / LCD digital display), as per
specification. The scope also includes providing
4" flanged , puddle pipe approximate 300 mm
long including fixing of the same in civil
structure slabe of pump house for mounting of
level Transmitter.The work also include all
necessary work like make hole,repair /
modificationin existing slab, etc.Level
Transmitter having following measurement
ranges for liquid (Water) application:
Meas. Range: upto 10 m (at any one
compartment of sump)
The Scope also make hole in existiing civil
structure and installl the Level Sensor.
2.1.2 Supply, installation, testing and commissioning 1 Nos. 12,802.00
of Float type Level Switch along with 10 mtr.
Cable and WP Junction Box (at wet well for dry
run protection of pumps) complete in all respects
and as per specification.The scope also includes
providing 4" flanged , puddle pipe approximate
300 mm long including fixing of the same in
civil structure slabe of pump house for mounting
of level switch.The work also include all
necessary work like make hole,repair /
modificationin existing slab, etc.
Meas. Range: upto 6 m (at any one compartment
of sump for dry run protection of pump)
2.1.3 Supply, installation, testing & commissioning of 1 Nos. 17,718.00
Float & Board type level indicator along with
all accessories, hardware, etc.complete in all
respects as per specifications and having
following measurement ranges:Meas. Range:
upto 6 m (at any one compartment of sump)
3.1.1 HOOKUP WITH EXISTING PLC PANEL 1 Job 35,000.00
Hookup of New Proposed Pump, MFM, PT, LT,
Large Display, MOV,etc. with existing PLC
Panel shall be carried out by success full bidder
and AMC shall be arrange to provide the access
in Existing PLC Panel to succesfull bidder for
data hook of Proposed items and programming
in PLC for auto operation of pump as per
instruction of Client/ AMC.
4.1.1 INSTRUMENT CABLE & ACCESSORIES 200 MTR 141.00
'Supply, Laying, Installation, Connection,
Termination, Testing & Commissioning of
Instrument Cables, along with cable glands,
lugs, cable trays, required junction boxes,
fittings and accessores as per specs.
The unit rate shall include
a. Supply, loading & unloading of the cable at
site from store.
B. Shifitng of cable from site store to place of
c. Fixing of cable clamps, brackets, supports,
route markers etc. where ever required to fix the
d. Excavation, back filling and levelling of
ground alongwith laying of fine sand, protection
bricks and other necessary civil material for
laying cables outside the building.
e Testing and submission of sketches & reports
of all the cables laid.
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.2 CONTROL CABLE 100 MTR 128.00
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.1.3 CONTROL CABLE 100 MTR 410.00
4.1.4 SIGNAL CABLE 500 MTR 150.00
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.2.1 INSTRUMENT CABLE TRAY 50 MTR 302.00
GI Perorated type cable tray shall be made out of
galvanized MS sheets of 2.0 mm thickness with
required asccessories . All material shall be Hot
dip galvanised (816 g/m2) as per IS 2629 as
mentioned in specification and tray hardware
shall be in GI.
50 x 50 mm - Perforated type
Cable Length is Approx. Provide as per
Actual Site Requirements.
4.3.1 CABLE END TERMINATION AND 10 Nos. 57.00
'Supply, fixing, connection, testing and
commissioning of double compression brass
cable glands and crimping type Bimetalic lugs /
sockets with necessary tools and equipments as
specified in specifications and IS complete in all
respects. The glands and lugs / sockets shall be
suitable for cable size and type mentioned above.
The job also includes earthing the glands and
armour of the cable with common earth bar or
flexible copper mesh as applicable.
4.3.2 CONTROL CABLE 10 Nos. 49.00
4.3.3 CONTROL CABLE 12 Nos. 180.00
4.3.4 SIGNAL CABLE 15 Nos. 41.00
TOTAL ESTIMATE OF INSTRUMENTATION WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev Trilok of North
work West Zone of AMC.
ELECTRICAL WORK
1.1.1 SITC of Lighting Distribution Board (LDB) as 2 Nos. 7,494.0
3 Phase 4 Wire TPN, 6 way Prewired LDB (One
each for Indoor & Outdoor Lighting) Suitable to
Incoming: 32A FP, ELMCB (30mA)
Outgoing: 20A SP MCB 'C' curve (9 nos.) & 16A SP
MCB 'C' curve (9 nos.)
(At Panel Room)
1.1.2 SITC of Power Distribution Board (PDB) as 1 Nos. 9,869.0
3 Phase 4 Wire TPN, 8 way Pre-wired-MOG / MOV
PDB for Auxiliary accessories Load power supply
(For MOV Pump delivery valves, valve at Header &
for auxiliary load & spare):
Incoming: 63A 4P, MCB 'C' Curve
Outgoing: 10 Nos. 32A 4P MCB 'C' Curve
1.1.3 LOCAL CONTROL STATION 5 Nos. 2,800.0
SITC of Pendant type ON_OFF LCS with
pushbutton set complete with Enclosure, necessary
mounting/ fixing arrangement on wall / pipe support
etc. to be installed near motors for remote operation,
etc. as per IS and specifications. (including structural
steel) (For 3 nos. HSCF Pump, 2 no. Chlorine
1.1.4 SITC of Local Control Station with pendant type 4 Nos. 4,500.0
Open_Stop_Close pushbutton set and with Open,
Close, Trip & Local / Remote Indicating Lamps
complete with Enclouser, necessary mounting/
fixing arrangement on wall / pipe support etc. to be
installed near motors for remote operation, etc. as per
IS and specifications (including structural steel)
(For Delievery Valve of Each Pumps )
2.1.1 LOW VOLTAGE (LT) CABLES 300 Mtr 243.00
Supply and unloading & delivery at site, storage &
security at site of 1.1 kV, A2XFY/2XWY XLPE
insulated (IS 7098) / PVC insulated (IS 1554) AL /
Cu conductor cables as per specification & IS. The
cable when laid outside the building shall be laid
underground in excavated trench, as per specified
method and shall be laid in prepared trench on cable
tray when laid inside the building.
3C x 70 sq. mm. A2XFY Cable (1 Runs for PMCC
Panel to HSCF Pump-Motor set.)
Cable Length is Approx. Provide as per Actual Site
2.1.2 3C x 35 sq. mm. A2XFY Cable (2 Runs for PMCC 80 Mtr 144.00
Panel to Existing Polder Pump.)
Cable Length is Approx. Provide as per Actual Site
2.1.3 4C x 6 sq. mm. A2XFY Cable (For Outdoor LDB, 300 Mtr 78.00
Indoor LDB, 1nos. MOVPDB)
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.1.4 4C x 10 sq. mm. 2XWY/2XFY Cable (For FP 100 Mtr 295.00
MCCB for 1 nos. PDB)
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.1.5 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For TPN 500 Mtr 81.00
MCB for Chlorination Room, TPN MCB at PMCC
room & Pump house maintenance floor & Pump
House floor, Chlorination system, Motor Operated
Valves,)Cable Length is Approx. Provide as per
Actual Site Requirements.
2.1.6 3C x 2.5 sq. mm. 2XWY/2XFY Cable (For Outdoor 50 Mtr 86.00
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.1.7 2C x 2.5 sq. mm. 2XWY/2XFY Cable (For Each 300 Mtr 177.00
Motor space heater(as required),for level switch)
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.1.8 5C x 1.5 sq. mm. 2XWY/2XFY Cable (For 1 Nos. 200 Mtr 130.00
Dewatering Motor LCS & 1no. Chlorine Booster
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.1.9 7C x 1.5 sq.mm. 2XWY/2XFY Cable (For Each 150 Mtr 115.00
Motor LCS with Ameter)
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.1.10 12C x 1.5 sq.mm. 2XWY/2XFY Cable (For Actuator 250 Mtr 390.00
LCS of Each Main Pump and Header)
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.1.11 10Tride x 1.0 sq.mm. individual triad and overall 300 Mtr 460.00
shielded with aluminum mylar tape Signal Cable for
RTD & BTD of motor (1Run Motor to S/S Panel)
Cable Length is Approx. Provide as per Actual
Site Requirements.
2.2.1 CABLE END TERMINATION AND 4 Nos. 302.00
SITC of Double compression Weather proof type Ni-
Plated brass cable glands and crimping type
Bimetalic lugs / sockets with necessary tools and
equipments as specified in specifications and IS.
The glands and lugs / sockets shall be suitable for
cable size and type mentioned below & as per
specificaitons.
1) Earthing the glands and armouring with earthing
clamp and jumper and also connecting to common
2) The job also includes, if necessary, supply &
fixing of extension busbar of same material on
MCCB or panel board terminal / connector to
connect more than one no. of parallel cables or to
connect higher size cable to lower size unit. The job
also includes earthing the glands and armour of the
cable with common earth bar or flexible copper
mesh.(Cable termination qty. shall be as per site
3C x 70 sq. mm. A2XFY Cable (1 Runs for Main
PMCC Panel to HSCF Pump-Motor)
2.2.2 3C x 35 sq. mm. A2XFY Cable (2 Runs for PMCC 4 Nos. 219.00
Panel to Existing Polder Pump.)
2.2.3 4C x 6 sq. mm. A2XFY Cable (For WR-DB with 8 Nos. 111.00
TPN MCB at Sump & Pump House, Outdoor LDB,
Indoor LDB, 1nos. MOVPDB)
2.2.4 4C x 10 sq. mm. A2XFY Cable (For TPN MCB for 4 Nos. 128.00
2.2.5 4C x 2.5 sq. mm. 2XWY/2XFY Cable (For TPN 20 Nos. 77.00
MCB for Chlorination Room, TPN MCB at PMCC
room & Pump house maintenance floor & Pump
House floor, Chlorination system, Motor Operated
2.2.6 3C x 2.5 sq. mm. 2XWY/2XFY Cable (For Outdoor 60 Nos. 76.00
2.2.7 2C x 2.5 sq. mm. 2XWY/2XFY Cable (For Each 12 Nos. 75.00
Motor space heater(as required), HT Panel, X'mer
marshaling box Single Phase Supply, for level
2.2.8 5C x 1.5 sq. mm. 2XWY/2XFY Cable (For 1 Nos. 6 Nos. 150.00
Dewatering Motor LCS & 1no. Chlorine Booster
2.2.9 7C x 1.5 sq.mm. 2XWY/2XFY Cable (For Each 8 Nos. 75.00
Delivery and Header LCS with Ameter)
2.2.10 12C x 1.5 sq.mm. 2XWY/2XFY Cable (For Actuator 8 Nos. 105.00
LCS of Each Main Pump and Header))
2.2.11 10Tride x 1.0 sq.mm. individual triad and overall 6 Nos. 185.00
shielded with aluminum mylar tape Signal Cable for
RTD & BTD of motor (1Run Motor to S/S Panel)
3.1.1 CABLE TRAY 200 Mtr. 402.00
SITC of GI ladder type cable trays with side
channels of size - 75 x 15 x 15 mm/ 100 x 15 x
mm & rungs of size - 35 x15 x 15 mm spaced at
mm apart, fabricated from 2 mm thick sheet steel in
standard length of 2.5 meter, duly hot dipped
galvanized after fabrication as per IS 2629- 1989/ IS
4759-1984 including accessories such as coupler
plates/ fish plates, bends, tees, reducers, elbows,
covers and electro- galvanized hardware etc, erected
on existing support as per specification and
instruction of engineer in charge.
150 mm (W) x 100 mm (H) - Ladder type ( Tray
RMT is Approx. Provide as per Actual Site
3.1.2 300 mm (W) x 100 mm (H) - Ladder type ( Tray 100 Mtr 456.00
RMT is Approx. Provide as per Actual Site
3.2.1 Supply & laying GI perforated type cable trays 100 Mtr. 228.00
with returned edge/ flange, fabricated from 2.0 mm
thk sheet steel in the standard length of 2.5 mtrs, duly
hot dipped galvanized after fabrication as per IS
2629-1989 / IS 4759-1984 including accessories
such as coupler plates/ fish plates, bends, tees,
reducers, elbows, covers and electro-galvanized
hardware etc, erected on existing support as per
specification and instruction of engineer in charge.
100 x 50 mm x 2.0 mm thick ( Tray RMT is
Approx. Provide as per Actual Site
3.2.2 150 x 50 mm x 2.0 mm thick ( Tray RMT is 100 Mtr 336.00
Approx. Provide as per Actual Site
3.3.1 Cable Trench, Laying & Installation of Cable: 20 Mtr 55.00
Making cable trench in soft soil of suitable width of
90cms deep for laying cable all over the run and back
filling the same and making the surface as normal
ground as per IS & Specification. (For laying LT
cable in ground)
3.3.2 Cable Covering in Trench: Cable Covering with 20 Mtr. 139.00
second class bricks or cement tiles laid cover the
cable crosswise & also on both side with covering of
7.5cms. Layer of sand above & below cable (16
bricks per meter.) as per IS & Specification. (For LT
3.4.1 Supply, laying and erection of 120 mm approved 50 Mtr 136.00
make Double Walled Corrugated pipes (DWC) of
polyethelene (confirming to IS 14930 II) with
necessary connecting accessoies of same material at
required depth for laying of cable below ground /
road surface for enclosing cable and back filling the
same to make ground as per original. (LT cable).
3.4.2 Supply, laying and erection of 90 mm approved 100 Mtr 95.00
make Double Walled Corrugated pipes (DWC) of
polyethelene (confirming to IS 14930 II) with
necessary connecting accessoies of same material at
required depth for laying of cable below ground /
road surface for enclosing cable and back filling the
same to make ground as per original. (For Motor
3.4.3 Supply, laying and erection of 50 mm approved 100 Mtr 62.00
make Double Walled Corrugated pipes (DWC) of
polyethelene (confirming to IS 14930 II) with
necessary connecting accessoies of same material at
required depth for laying of cable below ground /
road surface for enclosing cable and back filling the
same to make ground as per original.
4.1.1 CHEMICAL EARTHING SYSTEM 4 Nos 7,025.0
SITC of chemical earthing with earthpit of minimum
bore size dia. 225 mm Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS-
3043:1987 made of corrosion free G.I. Pipes having
Outer pipe dia of 80 mm having 80-200 Micron
galvanising, Inner pipe dia of 40 mm having 200-250
Micron galvanising or copper coated solid steel road
/ flat strip type connection terminal 14mm dia with
constant ohmic value surrounded by highly
conductive corrosion resistant chemical compound
with high charge dissipation suitable for electrical
installation of 11 kV & 440V of 2 Mtr. length of Pipe
with one no. 25Kg. bag of Back filling compound.
(Each Motor and other Electrical Accesories )
4.1.2 Supply, laying and erection of 25 mm(w) x 6mm(T) 60 Kg 77.00
etc. sizes as required, HOT dip galvanized GI Strip
including supply & fixing using GI spacers,
saddles when laid inside the building and inclusive
of excavation & refilling of earth when laid outside
the building & interconnection with earth pit & all
electro-mechanical equipments.(25X6 G.I Strip
wt.0.6 kg/m, 0.6x 100 Mt.=kg.)(Motor etc.)
4.1.3 SITC of HOT Dip Galvanized iron strip wire 8 SWG 21 Kg 77.00
(For LDB, PDB, LCS, etc.)
(8 SWG G.I Strip, 0.103 Kg/m, 0.103 x 200Mt.=21)
5.1.1 INTERNAL WIRING 300 Mtr 95.00
SITC of Mains & outlet points wiring with 1.1 kV
grade FRLS PVC insulated ISI marked flexible
stranded copper conductor wires with medium class
min. 25mm. dia. Rigid PVC pipe and accessories
to be erected concealed in / to be run on surface / wall
/ ceiling with following sizes as mentioned below.
The unit rate wirings shall be with connector, PVC
junction box, wires, holder, ceiling rose, angle
holder, switch, sockets, switch board, brass
chromium / cadmium plated machine screws, phase
and neutral wires, green Earth continuity wires etc.
as required to complete wiring from LDB panel to
the final outlet termination points. The wiring shall
be as per IS:732, IS:4648 and as per tender
specification / IS.
(a) SITC of Mains wiring with 3 wire 1.5 sq.mm .as
per tender specification & IS
5.1.2 (b) SITC of Mains wiring with 3 wire 2.5 sq.mm as 300 Mtr 124.00
per tender specification & IS.
5.1.3 (c) SITC of Mains wiring with 4 wire 1.5 sq.mm as 300 Mtr 114.00
per tender specification & IS.
5.1.4 (d) SITC of Mains wiring with 4 wire 2.5 sq.mm as 300 Mtr 147.00
per tender specification & IS.
5.2.1 SITC of Point wiring for Light / fan / Bell / 50 Nos. 445.00
Primary Point with 2nos. 1.5 sq. mm & earth wire
of 1.5 sq. mm (green) both are of ISI marked 1.1 kv
grade FRLS PVC insulated multistrand copper
wires, pipe to be erected concealed in flushed
on wall / ceiling, complete with 6A Tissino Type
ISI marked flush type switch / bell push &
accessories erected on metal / PVC Box covered with
3 mm thick PC (Polycarbonate) / Acrylic sheet
with necessary lamp holder / ceiling Rose / H. D.
connector as directed with medium class Rigid PVC
pipe & accessories.
5.3.1 SITC of 6A independent Plug with 2 nos. 1.5 sq.mm 7 Nos 310.00
Cu. Mains size wiring & earthwire of 1.5 sq.mm
(green) both are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multi strand copper wiress with
medium class rigid pvc pipe erected with ISI
marked 3 / 5 Pin socket and 6A Modular type switch
and accessories with earth continuity of following
type erected on PVC / Metal box, single mounting
base frame covered with textured/metallic/white
front plate modules erected on / in wall / ceiling as
per pipe erected. with necessary ceiling rose /
H.D.Connector as directed.
( For HT Room / Pump House / LT Room /
Chlorination Room)
5.4.1 SITC of One 300/380 mm dia. Ex fan 16A 6 Nos 829.00
independent Plug point near Ex. Fan with 2nos.
sq.mm Cu. Mains size wiring & earthwire of
sq.mm (green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multistrand copper wires with
medium class Rigid PVC pipe and accessories to
be erected complete with Modular type switch &
pin Plug erected on PVC / Metal box covered with
appropriate front plate modules erected on / in wall /
ceiling as per pipe erected with following type of
accessories. Plug point shall be near Ex.Fan.
(For Pump House Room /Chlorination Room)
5.5.1 SITC of 6/16A independent Plug with 2nos. 4 sq.mm 6 Nos 601.00
Cu. Mains size wiring & earthwire of 2.5 sq.mm
(green) both are of ISI marked 1.1 KV grade
FRLS PVC insulated multistrand copper wires with
medium class Rigid PVC pipe and accessories to be
erected on wall / ceiling, complete with ISI marked
3 / 5 Pin socket and tissino type switch erected with
earth continuity connection erected on Metal / PVC
box covered with 3 mm thick PC(Polycarbonet) /
Acrylic sheet. .
(For HT Room/Chlorination Room / Pump House/
5.6.1 SITC of Single Phase 20A 3 Pin Metal clad 2 Nos. 845.00
Industrial Type Socket with plug top and 20A
SPMCB, suitable for flush mounting, in 16 SWG MS
box of suitable size and covered with 3 mm thick
electrical grade hylam sheet or eqivalent ISI marked
Electrical grade bakelite sheet and earthing with
2.5 sq.mm insulated copper wire run inside the
conduit including interconnections etc. complete as
required.( For Pump House/ LT Room)
6.1.1 1200 mm sweep ceiling fan, capacitor type, 3 Set 1,581.0
having double ball bearing 450mm down rod,
canopies, shackle, rubber bush, blades, electronic
speed regulator, suitable to operate on 230V,50Hz
AC supply conforming to IS: 374/1979.Fan shall be
painted with white colour.
(For LT Panel / HT Room / Torrent Room )
6.2.1 380 mm sweep 1400 R.P.M exhaust fan, 6 Nos. 3,052.0
capacitor type, having double ball bearing,
M.S.blades, mounting frame, forearms, suitable to
operate on 230V,50 HZ AC supply conforming to IS:
2312.Fan shall be painted with epoxy grey colour
controlled by one 6 A flush type switch on board and
6A plug point near Ex. fan. With Bird Net
(For Pump House/ LT Room and Chlorination
7.1.1 LED LIGHT FIXTURES: 25 Nos 530.00
SITC of Indoor wall mounting LED indoor fittings
with LEDs of wattage 0.2 Watt to 0.5 Watt
assembled on single MCPCB, with housing used as
a heat sink shall be made of thick sheet Steel
conforming to IS: 513/CRCA polyester powder
coated and high U.V. & corrosion resistance with
diffuser and/or Polycarbonate optics with company
mark/name 120 to 300 V,Power Factor more than
Uniformity ratio >0.7, Luminaire efficacy>
LED driver efficiency > 85 %
(Each fitting required LM-79 & LM-80 Certificates)
40 Watt or up to 25% higher wattage Tube Light with
integral / non-integral driver, Surge-2KV, IP-20,
(For Existing Room/ LT Room/ Chlorination Room/
7.2.1 SITC of Surface/Wall mounted LED Indoor 16 Nos. 6,028.0
Flood light fittings with High power White LEDs
wattage of 1Watt and above assembled on single
MCPCB, efficiency more than 130 lm/w and
corrosion free High pressure die cast aluminum
housing with smooth finish powder coated and heat
sink extruded aluminium with diffuser and
Polycarbonate optics/ lenses with company
mark/name engraved or embossed
120 to 300 V,Power Factor more than 0.95, THD <
Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED
driver efficiency > 85 %.
( Each fittings required LM-79 & LM-80
90 Watt Indoor Flood Light (IP-65), Surge -4KV
(for pump house cum Panel room)
7.2.2 SITC of 'B' class galvanised iron pipe 32 mm outside 16 Nos. 340.00
dia 45 cmslong duly welded on 20 cms x 20 cms x
mm thick M.S. base plate, erected on wall or corner
for mounting luminaire with necessary hardware
materials duly painted for wall mounting indoor
flood light fixtures on Wall of Buildings.
7.3.1 EXTERNAL LED LIGHT FIXTURES & 20 Nos. 6,028.0
SITC of Wall mounted 80W LED Outdoor Flood
Light fittings with High power White LEDs wattage
of 1Watt and above assembled on single MCPCB,
efficiency more than 130 lm/w and corrosion free
High pressure die cast aluminum housing with
smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/
lenses with company mark/name engraved or
embossed 120 to 300 V,Power Factor more than
Uniformity ratio >0.45, Luminaire efficacy>
lumens/watt . LED driver efficiency > 85 %. ( Each
fittings required LM-79 & LM-80 certificates) Flood
Light (IP-65), Surge -4KV, 80 watt Cat-III(for
outside Area Lighting as per instruction given by
the engineer In-Charge.)
7.3.2 SITC of 'B' class galvanised iron pipe 32 mm 20 Nos 340.00
outside dia 45 cms long duly welded on 20 cms x
cms x 3 mm thick M.S. base plate, erected on wall or
corner for mounting luminaire with necessary
hardware materials duly painted for wall
mounting indoor & outdoor flood light fixtures on
Wall of Buildings.
8.1.1 SAFETY ACCESSORIES 4 Nos 8,586.0
SITC of following safety accessories complete
with necessary fixing brackets, other accessories
and tools etc. as required to complete the job.
Supply & Erecting carbon dioxide (CO2) fire
extinguisher of 6.5 kg capacity with necessary
clamps made from 50 x 6 mm M.S. Flat with nut &
bolts grouted in wall complete.
(For X'mer./ HT Room/ LT Room/ Pump House)
8.1.2 Supplying stand first AID box with anticeptic 2 Nos. 297.00
cream, medicine for use on wounds due burn, crepe
bandage, guage bandage, medicated ready to use
bandage (Band-aid) adhesive tape for medicinal
user, scissors, anticeptic solution (Savlon or similar)
(All above contents shall be of standard makes)
(For Pump house / LT Room)
8.1.3 Supply & fixing of printed instruction (First Aid) 1 Nos. 129.00
Chart both in English and Gujarati and duly framed
with front glasses, for treatment of person suffering
from electric shock.
8.1.4 Supplying & fixing of FIRE bucket round bottom 8 Set 212.00
of 9 litres capacity made out of 24 guage G.I. sheet
with extra handle at bottom duly painted white inside
and Red outside with FIRE mark, filled with dry sand
and kept on stand provided or hung on wall hook.
8.1.5 Supplying and erecting floor mounting stand for 1 Nos. 933.00
keeping four nos. of FIRE buckets comprising
mm in length, 900 mm height frame made out of
30mm X 30 mm X 4 mm angle iron with cross
supports for legs, welded with 4 hooks and duly
painted with one coat of red lead and two coats of
approved enamelled silver paint.
8.1.6 Supply and fixing of 30 W fluorescent lamp operated 1 Nos. 4,912.0
emergency light with maintenance free battery for 3
hours operation during mains power failure.LED
Portable/Rechargeable flood light having die - cast
aluminium enclosure designed for maximum thermal
efficiency of 130lm luminous efficiency at voltage
supply between 140-270V AV/12V DC at operating
temperature of -20 degree to 60degree celcius with
battery back up 3-4hrs
8.1.7 Supply and laying of Synthetic Insulating Mat of 6 Mtr 1,017.0
Class - B of min. thickness 2.5 mm as per IS:15652
and with good electrical insulation property for
11kV/22KV as per site requirement.
8.1.8 Supply and laying of Synthetic Insulating Mat of 10 Mtr 763.00
Class - A of min. thickness 2 mm as per IS:15652
and with good electrical insulation property for
1.1KV/3.3KV as per site requirement. .
(for PMCC Panels)
8.1.9 Providing pair of rubber hand gloves ISI make 2 Nos. 212.00
suitable for working on 22 KV supply
9.1.1 MISCELLANEOUS: 500 kg 64.84
Providing, Supply of Structure Steel at site of work
with freight, loading, unloading carting, etc.
including all taxes and duties complete such as
joints, channels, angles, Iron Rails,
ISA/ISMC/ISMB/MS flat, Plates, Chequered plates
(below 10mm thickness) etc. required for support
structure of Elecrto-Mechanical equipments etc. for
support on floor / wall / beam / brackets etc. as per
9.2.1 Labour Charges for lowering, laying, Fixing with 500 kg 11.36
fabrication various size section of MS such as joints,
channels, angles, Iron Rails, ISA/ISMC/ISMB/MS
flat, Plates, Chequered plates etc Complete with two
coats of red oxide and two coats of approved colour
shade of epoxy paint as per relevant IS and as per
10.1.1 LIASONING CHARGES FOR OBTAINING 1 Ls 25,000.
Liasoning Charges for obtaining N.O.C from
Electrical Inspector / Statutory authority for Power /
Ele. Installation. (Fees shall be paid by tenderer for
obtaining N.O.C. from Electrical Inspector /
Statutory authority on behalf of client and shall be
reimbursed on submission of orignial receipt to
Client). Liasoning Charges shall include preparing
required attasted documents & drawing for obtaining
NOC on behalf of client (Applicable Fees / deposits
shall be reimburse by Client).
SUPPLY BELOW ITEMS AT RAIKHAD AMC STORE
11.1.1 Supply and laying of Synthetic Insulating Mat of 50 Mtr 1,017.0
Class - B of min. thickness 2.5 mm as per IS:15652
and with good electrical insulation property for
11kV/22KV as per site requirement. (Use At HT
11.2.1 Supply and laying of Synthetic Insulating Mat of 500 Mtr 763.00
Class - A of min. thickness 2 mm as per IS:15652
and with good electrical insulation property for
1.1KV/3.3KV as per site requirement. (Use At LT
11.3.1 Providing pair of rubber hand gloves ISI make 15 Nos. 212.00
suitable for working on 22 KV supply
11.4.1 Supply & fixing of printed instruction (First Aid) 100 Nos. 129.00
Chart both in English and Gujarati and duly framed
with front glasses, for treatment of person suffering
from electric shock.
TOTAL ESTIMATE OF ELECTRICAL WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical, Electrical,
of Instrumentation and Civil works for Water Distribution Station At Bodakdev Trilok of
Work North West Zone of AMC.
ITEM QTY RATE UNIT AMOUNT
Demolition of Brick work & stone masonry
including stacking of serviceable materials and
disposal of unserviceable materials with all lead
and lift. (i) In cement Mortar.
Demolition and disposal of unserviceable
2 materials with all lead and lift.(i) Unreinforced 10.00 603.23 Cmt
cement concrete
Demolition and disposal of stacking of
serviceable materials and disposal of
unserviceable materials with all lead and lift (i)
Clearing and grubbing road land including
uprooting rank vegetation grass
bushes,shrubs,sapling and trees girth up to
4 0.10 79449.30 Hectare
mm removal of stumps of trees cut earlier and
disposal of unserviceable materials (C) By
mechanical means in area of light jungle
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
5 architraves, holdfasts and other attachment etc. 10.00 185.85 Each
complete and stacking them within all lead and
lift.(i) Not exceeding 3 Sq.M. in area.
Dismentling doors, windows, ventilators etc.
(wood or steel) shutters including chowkhats
6 architraves, holdfasts and other attachment etc. 5.00 248.85 Each
complete and stacking them within all lead and
lift.(ii) Exceeding 3 Sq.M. in area.
Dismentling barbed wire in fencing including
making rolls and also including dismentling
fencing posts including all earth work concrete
7 in base and making good the disturbed ground 150.00 66.15 Rmt
stacking useful materials as directed and
disposing as directed and disposing of the
unserviceable materials with all lead and lift.
Removing and scraping of old deteriorated
plaster of any thickness from all Structural &
Non Structural member including stacking of
8 serviceable material and disposal of 300.00 19.38 Sq.mt
unserviceable from site of work with all lead and
Supplying Electric breakar machine for RCC
slab or Asphalt demolishing work on site by
using operator, fuel, power supply etc. complete
9 as directed.(no payment should be allowed for 3.00 1071.43 Shift
non working condition of machinary and for
pipeline excavation and M.H. work.allowed
only for break down work)
Providing and Laying of Rubber Moulded Paver
Block Grey/Coloured 60 mm thick, M-35 Grade
of any size ; shape (Usually Uni-Paver Blocks)
using black trap good quality aggregate of
mm nominal size for footpath, parking areas,
service lanes and other areas as mentioned in the
drawing / instruction of engineer in charge. Cost
includes formworks using rubber mould, Rate
providing and laying paver blocks as per
required grading and specification. The paver
block shall be mechanically compacted. The
10 work of paving blocks shall be executed in line 265.00 383.04 Sq.mt
and level by skill mason of flooring work only.
It should be laid in such a way that the no cutting
of the paver block to be necessary. If cutting of
paver block necessary then it should be cut by
machine only and carting. The finished surface
of the paver block shall have reasonably good,
plain finished. Paver blocks shall be compacted
and shall be relaid if necessary. Gravel or such
type of materials shall not be allowed for
production. Laying on 5 cms thick sand bedding.
Supplying and fixing of 300 mm-L x 150 mm-B
x 380 mm-H Kerb block for Footpath in M-20
grade using 20 mm nominal size black trap
aggregate of Sevaliya/Timba or equivalent
quality for pre-cast blocks, reasonably exposed
finish/ formwork , mould with well equipped
with vibratory system for kerb stones of
approved design including curing, etc. complete,
including the cost of formwork etc. complete.
The rate shall also include necessary cutting of
asphalt, fixing the Kerb stones in line and level
on 5 cm thick sand bedding with necessary
equipments and materials. The rate shall also
include the flush pointing in CM (1:3) for all
joints of the kerbstones. Filling of zari alone the
sides of the kerb stone fixed with Bituminous
concrete Bituminous concrete / C.C. mixed in
proper position to flush with the road surface as
directed by Engineer in change to form a
portable mixture.
Laying on 5 Cms thick sand Bedding 75.00 350.89 Rmt
Removing any kind of pavement incl stacking of
12 serviceble material disposal of unserviceble 50.00 14.00 Smt
material with 50 meter lead and lift.
Labour work for fixing above interlocking
blocks on up to 50mm th sand bedding,
levelling, watering and fixing. Rate incl. average
13 30cm depth for excavation and or filling, carting 50.00 68.64 Smt
away debries/excavated material up to 5 km and
cleaning the site etc. Comp. as directed.
Excavation for foundation for loose and soft soil
including sorting out and stacking of useful
materials and disposing of the excavated stuff up
14 to 50 meter lead.
Conveyance charge of earth, lime, murrum,
building rubbish, manual garbage, sludge,
excavated rock, fly ash, aggregate of any kind
etc. Upto 5.0 Km lead.
Conveyance charge of earth, lime, murrum,
building rubbish, manual garbage, sludge,
16 excavated rock, fly ash, aggregate of any kind 7.50 334.14 Cu.m.
etc. 5Km to 10 Km lead.
Filling with available excavated earth
(excluding rock) in trenches, plinth, sides of
17 foundation in layers not exceeding 20 cm in 60.00 129.10 Cu.m.
depth consolidating each deposited layer by
ramming and watering.
Providing and casting in situ C.C. in grade M-15
(approx. corresp. to prop. 1:2:4) (proportions as
per mix design or as per Table 9 of IS456
in masses by weigh batching ) using granite,
quartzite trap metal of size 6 mm to 20 mm for
RCC work, including scaffolding centering,
form work, needle vibrated consolidation,
curing comp. (excluding cost of reinforcement
and neat finishing) with centering and
shuttering/deshuttering etc. comp. for structure
for other than water retaining. Footing (with
Providing and casting in situ C.C. in grade M-15
(approx. corresp. to prop. 1:2:4) (proportions as
per mix design or as per Table 9 of IS456
in masses by weigh batching ) using granite,
quartzite trap metal of size 6 mm to 20 mm for
RCC work, including scaffolding centering,
19 form work, needle vibrated consolidation, 15.00 4730.00 Cu.m.
curing comp. (excluding cost of reinforcement
and neat finishing) with centering and
shuttering/deshuttering etc. comp. for structure
for other than water retaining. Footing (without
Providing and cast in situ C.C. in grade M-20(
proportions as per mix design or as per table of
IS456 2000 in masses by weigh batching) using
granite, quartzite trap metal of size 6 mm to
mm for RCC Work including scaffolding
centering formwork, needle vibrated -
consolidation, curing complete up to 6 meter
depth or height (excluding cost of reinforcement
and neat finishing) with centering and
20 shuttering/ deshuttering etc. complete for
structure other than water retaiing.
A) RCC Footing 20.00 5520.00 Cu.m.
B) RCC column 5.00 7363.00 Cu.m.
C) RCC Beam 10.00 6722.00 Cu.m.
D) RCC Coping 5.00 6722.00 Cu.m.
E) RCC Slab 5.00 6504.00 Cu.m.
F) RCC Wall 5.00 6779.00 Cu.m.
Supply cutting, Bending, Binding and placing in
position steel as per plan and design and as per
ISS 2502 including cost of steel and binding
wire for reservoirs/ structures only including lift
21 up to 6 meter height or depth below G.L. for all 3.00 77504.00 MT
Deformed(TMT)bars confirming to relevant IS
Fe-500 grade for all diameters.
Brick work using common burnt clay building
bricks having crushing strength not less than
35kg / Sq. C. M. in ramp, steps and Foundation
22 & Plinth in cement morter1:5 (1 cement : 5 5.00 4011.66 Cu.m.
coarse sand) including racking out joints, curing,
scaffolding required if any etc. complete, as
directed. (B) Conventional
Brick masonry in cement mortar (1:5) using
common burnt clay building bricks having
23 crushing strength not less than 35kg/cm2 15.00 4091.84 Cu.m.
including scaffolding,curing, etc. complete for
walls, parapets, etc. at all levels.
20 mm thick sand faced cement plaster on walls
upto height 10 metres above ground level
consisting of 12mm thick backing coat of C.M.
24 1:3 (1-cement : 3-sand) and 8 mm thick finishing 315.00 297.68 Sq.mt
coat of C.M. 1:1 (1-cement : 1 sand) etc.
Providing and applying 15 mm thick cement
plaster in single coat on brick work with floating
coat of net cement slurry for interior plastering
of pumphouse and outside plastering of sump
25 upto finished even and smooth in Cement motar 945.00 222.56 Sq.mt
1 : 3 (1 cement : 3 sand) including racking out
joint curing, scaffolding required if any, with
necessary cement finishing etc. complete as
Interior plain faced 15 mm thick cement plaster
(1:3) with floating coat of neat cement slurry on
Underneath Ceiling of top of UG tank where
26 specified on drawings and or engineer in charge 55.00 247.13 Sq.mt
at all levels including scaffolding, curing, etc.
complete. This rate shall include moulding
where specified.
Writing letter or figures on any surface with
black japan paint (stops, comas, hyphens and the
27 like not to be measured and paid for separately) 13.00 3.15
(i) Block (Letters/Figures) (Per 10 Letter pet
Providing throating or plaster strip / ghishi and
28 moulding as instructed by Engineer in charge 50.00 41.25 Rmt
Providing in line level plumb, fabricating and
fixing three row horizontal barbed wire fencing
and punched tape concertina coil of 9 turns per
meter of 610 mm diameter fixied with clips on
top of the angle iron posts. The punched tape
concertina coil having sharp barbs at every
29 mm spacing shall be 0.5 mm thick and 19 mm 160.00 449.00 Rmt.
width and weighting 13 Kg./100 mtr. (Average)
as per manufacture's specification. The rate
shall also include providing and fixed 1.20 mt.
total long MS angle 40 x 40 x 6 mm @ 3.00 mt.
c/c spacing embedded in RCC column, angle
posts shall be painted with one coats of red oxide
and two coats of enamel paint of approved
quality at top of compound wall.
Fabricating and fixing in position MS structural
section such as flat, pipes, plates, hold fast,
anchoring bolts / bars of required size including
fixing, welding and two coats of approved anti
corrosive paint over prime coat of red-oxide
including RCC gate column as per drawing etc.
complete as directed by Engineer-in-charge.
2.2 m height and 6 m wide main , wicket gate
and Toilet Block Door.
White washing with lime on wall surface (two
coats) to give an even shade including
31 thoroughly booming the surface to remove all 65.00 12.29 Sq.mt
dirt, dust; mortar drops and other foreign matter
Providing and laying broken Chine Mosaic
flooring for terrace using 12 mm to 20 mm
broken pieces of glazed tiles to be laid over
Cement mortar 1:3 to plain or slope and to be
32 tempered to bring mortar crème out upto surface 180.00 739.89 Sq.mt
using white cement including rounding of
junctions and extending them upto 15 cm. along
the wall, clearing with water and oxalic acid etc.
Distempering (two coats) with oil bound
distemper of approved brand and manufacture
and of required shade on undecorated wall
surface to give an even shade, over and
including a priming coat with distemper primer
33 of approved brand and manufacturer after 76.08 Sq.mt
thoroughly brushing the surface free from
mortar dropping and other foreign matter also
including preparing the surface even and sand
papered smooth.
Finishing wall with weather proof exterior
emulsion paint on wall surface (two coats) to
give an required shape even shade after
34 thoroughly brushing the surface to remove all 113.40 Sq.mt
dirt and remains of loose powdered materials.
Applying two coats of Birla(white cement
based) or Asian (acryliclapy putty) or equivalent
& two coats of primer of approved brand and
35 manufacture on new wall surface to give an even 40.19 Smt
shade including thoroughly brushing the surface
free from mortar dropping and other foreign
matte rand sand papered smooth.
Providing and fixing standared extruded of
alluminimum section of size 63mm x 38.10mm
x 1.2mm (Jindal Section : 2434, @ Wt.
36 Kg/mt.) with colour powder coated alluminium 11.34 1163.92 Sq.m
frame for ventilation with 5 mm thick frosted
glass as details etc complete for Ventilation'
Providing and fixing wsh down watercloset
(Europeantype,W.C.Pan) with integral Por S
trap including jointing the trap with soil pipei n
Cement Mortar1:1(1-Cement:1-fine sand) (Seal
37 and cover to beme asured and paid for 1.00 1875.68 No
separately) (A)vitreous China Pattern :(i) in
white colour 32 dia. C. P. brass half turn flush
cock complete including earthwork, bed
concrete of 1:4:8.''
Providing and fixing flat back white colour
vitreous china wash basin 550 mm x 400 mm
size with CI brackets painted white. Wash basin
shall have 15 mm dia GI supply pipe, overflow
chase, 15 mm dia pillar cock and stop cock with
PVC bottle trap and PVC pipe piece upto wall
38 plus 32 mm dia PVC waste pipe upto floor level 1.00 2084.70 No
connected to 32 mm dia CI pipe below floor and
connected to nearby floor trap complete with
unions and plumber's white soldered joints with
necessary cleaning eye, complete. All chases cut
in wall for fixing pipes shall be made good in
Providing and fixing Flat Back Urinal (
Hindware- 44cmx31.5cmx26.5cm) or
equivalent approved and of approved shade
including fixing the same in concealed CI
39 brackets, CP spreader, CP dome shaped waste 1.00 1535.63 No
coupling, CP bottle trap with flanges, CP angle
cock flush pipe making inlet and out let
connections all complete as per the instruction
of Engineer - In - Charge.
Providing, laying and jointing in true line and
level U.P.V.C. Pipe (SCH-40) for including
fittings make PRINCE / SUPREME / ASTRAL
/ FINOLEX or equivalent as approved by
Engineer In Charge. Pipe shall be fixed on the
wall with the help of clamp at every two metre
C/C or shall be concelled as directed including
necessary fittings etc. including testing of pipe
and joints and fixing the same with adhesive
solvent, including cost of all materials.'
Providing & fixing gun metal check or non
return full way wheel valve'' -
Providing and fixing brass screw down stop tap.
(A) 15mm dia.''
Providing and fixing screw down bib taps of
43 following size.(C)Gun metal screw down bib 5.00 157.29 No
tap. i) 15mm dia.'
Providing and fixing 150 mm x 100 mm
44 intercepting sewer trap embedded in concrete 2.00 976.00 No
complete including excavation and backfilling.'
Constructing Manhole with R.C.C. top slab in
1:2:4 mix (1-cement: 2-coarses and :4- graded
stone aggregate 20 mm nominal size) foundation
concrete 1:3:6 mix (1-cement : 3-coarse sand :
6-Brick bats 40+50 mm size) inside plastering
15 mm thick with Cement Mortar 1:5 (1-Cement
: 5-coarse sand)finished with a floating coat of
neat cement and making channels in cement
concrete 1:2:4 mix (1-Cement: 2-Coarses and :
4-stone aggregate 20 mm nominal size) finished
45 smooth complete including curing and festing (i) 1.00 11314.02 No
Inside size 900mm x 1200 mm and 2.0 M. deep
including C.I. cover with frame size 560mm
diameter total weight of cover and frame to be
not less than 128kgs. (Wt. of cover 64Kg. and
Wt. of frame 64Kg.) (A) With 230 mm thick
walls of brick msonry using brick having
crushing strength not less than 35Kg./Sq.cm. in
Cement Mortar 1:5 (1-Cement : 5-Coarse sand)
(1) A type depth 0.90 Metre for 150 mm
diameter sewer.''
Providing and fixing in position PVC vent pipes
46 of 160 mm dia 3 m length.' 1.00 910.00 No
Providing and fixing cast iron (Spun) Nahni trap
of the following nominal diameter of self
cleaning design with C.I. screaed down or
hinged grating including cost of cutting and
making good the walls and floor 100mm inlet
and 50mm outlet. (C) 100mm dia.
Providing and fixing S.W. gully trap with C.I.
grating brick masonry chamber and water tight
48 C. I. cover with frame of 300 mm x 300 mm size 2.00 1234.57 No
(inside) with standard weight. (i) Square mouth
traps.(B) 150mm x 100mm size P or R type
Providing and fixing100mm size P or Strap for
water closet squatting pan including jointing the
49 trap with the pan and soil pipe in cement 1.00 311.85 No
Mortar1:1 (1-Cement : 1-Fine sand) (A)
Vitreous China.'
Providing and laying (to level or slopes) and
jointing with stiff mixture of Cement Mortar in
50 proportion 1:1 Selt glazed stone ware pipes 30.00 288.23 Rmt.
including testing of pipes and joints
complete.(B)150mm dia. (upto 10 ton)
Constructing brick masonry chamber for under
ground C.I. Inspection chamber and bends with
bricks having crushing strength not less than
35Kg.Cm 2in C.M. 1:5 C.I. cover with frame
(Light duty) 455mm x 610mm internal
dimensions total weight of cover with frame to
be not less than 38Kg. (Wt. of cover 23Kg.) and
Wt. of frame 15Kg.) (R.C.C. top slab e with
1:2:4 mix (1-cement :2- coarse sand :4-graded
stone aggregate 20mm size) foundation concrete
1:5:10 inside plaster 15mm thick with cement
mortar 1:3 finished smooth with a floating coat
of neat cement on walls and bed concrete etc.
complete. (ii) Inside dimensions
500mmx700mm and 450mm deep for pipe line
with one or two inlets. (upto 10 ton)'
Providing and fixing over roof black colour PVC
overhead water tank of approved manufacture
with all necessary fittings and connection
etc,complete on terrace.'
Providing and fixing 600mm x 450mm bevelled
edge mirror of superior glass mounted on 6mm
53 thick A.C sheet or plywood sheet and fixed to 1.00 611.10 No
wooden plugs with C.P brasss crews
(B)600mmx20mm size.'
Providing and laying white glazed tiles 6 mm
thick in flooring, treads of steps,walls and
landing laid on a bed of 10 mm thick cement
54 mortar 1:3 (1 cement : 3 coarse sand) finishing 22.42 908.17 Sq.m
with flush pointing in white cement (Upto
Constructing Slab type M.H. Chamber of the
following size including excavation, refilling,
brick bats cement concrete (1:5:10) of thickness
15 C.M., CC Channel (1:2:4) of thickness
C.M., finished 15 mm thick cement plaster 12
inside & outside (Only for shaft) in CM 1:3,
finishing with cement slurry, P/F 4 mm dia
M.S.Steel HDPE coated steps 35 cm c/c at 35 cm
staggered in masonary CM 1:5, RCC Slab in CC
55 1:1.5:3 of thickness 23 C.M., including 5.00 10177.68 No
Cantering & reinforcement (double jalli at
C.M. c/c bothway 12 mm dia.) but excluding the
cost of machine hole seat cover etc..completed.
of Size 1.00 X 1.40 meter (Inside Clear,M.H.
length should be parallel to the flow, for pipe dia
<= 800 mm) (Based on Drainage SOR 2009-
10)1.00 to 2.00 meter depth, (Slab at Ground
level) for Rainwater Collection Chamber
Constructing Chamber of following size
including excavation, refilling, BBCC (1:5:10)
for foundation, C.C.Channel (1:2:4), finished
mm thick cement plaster inside in CM 1:3,
finishing with cement slurry, Brick masonary in
CM 1:5 & excluding the cost of chamber seat
cover etc..completed. (Based on Drainage SOR
2009-10) 0.60 X 0.45 mt. size Inside Clear,
Depth from 0.0 to 0.90meter for pipe dia <=150
mm. chamber for dewatering
Providing & Fixing F.R.C. MH seat cover incl.
carting to the work site etc. comp. Directed.
(Based on rate of central store) FRC medium
57 duty Chamber seat cover (FRC) cover 706 x 556 2.00 1633.93 No
x 50 mm rectangular cover frame size 600 x
mm clear opening outer size 816 x 666 x
mm (MD-10) cover for dewatering Chamber
Providing F.R.C. MH seat cover incl. carting to
the work site etc. comp. Directed. (Based on rate
of central store) F.R.C. Extra Heavy Duty
(EHD-35) machine hole Covers & Frames
Cover : 728mm ø & 100 mm thick circular
cover, 35.00 MT load design, 100x2mm MS flat
allround, 16mm ø plain round bar for lifting the
cover & should be fitted with plastic cups.
Frame : 560 mm ø clear opening, outer size-
888x888x175 mm. On the upper periphery of
frame 25 x 3 mm wide MS flat should be well
embed in concrete to protect the edges of frame.
FRC E.H.D.-35 machine hole cover & frame
described as above
Making connection to the ex.M.H.in running
sewer incl. Dewatering and other required
machinery etc. of following dia pipes at any
convenient time. All damaged work shall be well -
repaired as per instructions. etc..complete.
59 (Based on Drainage SOR 2009-10)
connection for dewatering
a) 150 mm to 300 mm dia. 2.00 1339.29 No
b) 400 mm to 600 mm dia. 2.00 2232.14 No
c) 700 mm to 900 mm dia 2.00 3125.00 No
Kota stone in Jams and Sills of the window and
60 ventilation and Door with one molding as 35.00 1107.00 Smt
directed by Engineer-in-charge.
Providing and fixing window having extruded
aluminum Colour anodized section frame main
outer size 95mm x 24mm x 1.17 mm (of Jindal
Section no : 2459 @ wt. of 0.738 Kg/mt),
horizontal Three track member size 92mm x
31.75 mm x 1.30 mm (of Jindal Section no.
8688, @ Wt. 1.07 Kg/mt), vertical member of
size 92mm x 31.75mm x 1.50 mm (of Jindal
Section no. 8933, @ Wt. 1.06 Kg/mt.) with
61 sliding shutters of horizontal member size 40mm 25.00 1568.27 Smt
x 18mm x .29 mm (of Jindal section no. 8947 @
wt. 0.456 Kg/mt.) vertical member of size 40mm
x 18mm x 1.29mm (of Jindal Section no.
@ wt. of 0.456 Kg/mt with 5 mm thick
transparent bronze colour tinted float glass with
powder coated aluminum fittings and fixtures
and transparent silicon sealant glass fixing to
frame as per details etc. PH Window and LT
Providing and fixing standared extruded of
alluminimum section of size 63mm x 38.10mm
x 1.2mm (Jindal Section : 2434, @ Wt.
Kg/mt.) with colour powder coated alluminium
frame for ventilation with 5 mm thick frosted
glass as details etc complete for Ventilation
Providing & fixing in position aluminium grill
with 15 micron natural matt brush finish
anodised as per over all size shown on the
drawings and aluminium sections of approved
make conforming to IS:733 and IS : 1285, made
out of DG - 104 design ( Jindal or equivivelent )
fixed with required size F channel, rawl plugs
and screws or with fixing clips, or with
expansion hold esters including necessary filling
up of gaps at junctions, at top, bottom and sides
with required PVC/neoprene felt etc. and
aluminium snap beading for glazing / panelling,
C. P.brass/stainless steel screws, including
standard anodised aluminium fittings and
fixtures of approved make and of adequate size
and in adequate numbers, including cost and
fixing of fixtures etc. complete as per detailed
drawings with all lead and lifts.
Providing precast cement concrete jali or louvers
40 mm thick 1:2:4 mix (1 cement : 2 coarse sand
: 4 graded stone aggregate 6 mm nominal size)
64 reinforced with 1.6 mm dia. Mild steel wire 15.00 640.20 Smt
including roughening, cleaning, fixing and
finishing in CM 1:3 and curing, painting
Supplying, fixing Push and Pull, 20 gauge
rolling shutter of approved make for the sizes
indicated on drawings including hood cover,
channel sliding assembly, helical coil springs,
65 brackets, interlocking latches, locking 25.00 4277.00 Smt
arrangements, painting with 2 coats of enamel
paint over one coat of approved primer paint etc.
complete. Shutters having width below 3.5M
(gear Operated)
Providing and laying cement concrete flooring
1:2:4 (1 cement : 2 coarse sand : 4 graded stone
aggregate 20 mm nominal size) including water
proofing compound finishing with a floating of
neat cement slurry etc. complete laid in one layer
finished including necessary curing at bottom of
Average 50 mm thick
Providing and laying polished Kota stone slab
flooring over 20 mm (average) thick base of
cement mortar 1:6 (1 cement : 6 coarse sand)
67 laid over and jointed with grey cement slurry 170.00 1085.48 Smt
including rubbing and polishing etc. complete at
LT & HT, office room & Chlorine room. 30 mm
Providing and laying polished Kota stone slab
25 mm thick in riser of steps, skirting Dedo &
pillars laid on 10 mm thick cement mortar 1:3 (1
cement : 3 coarse sand) and jointed with grey
cement slurry including rubbing and polishing
Providing and fixing 40mm dia. GI pipe medium
weight quality as openable type with angle iron
support at 1.5 m c/c using 75 x 75 x 10 mm
angles, 1 m long with three rows of pipes as
railing including necessary painting with two
coats of approved quality oil paint over one coat
of approved primer including necessary
welding, bolting required, if any.
Painting two coats including priming coat on
new steel & other metal surfaces with enamel
70 paint, brushing, interior to give an even shade 55.00 121.28 Smt
including cleaning the surface of all dirt, dust,
other foreign matter.
Providing, Fabricating & fixing WDS name
board of Size 3.00mX0.60 made from ISA
50X50X5 mm M.S angle with 3 Nos supports at
back side vertical member of angle size 1.1m ht
incl 0.3 m hold fast inserted in compound wall
with necessary dismantling and fixing with
cement concrete. The rate shall also incl 16 g
M.S sheet of size 3.00X0.60 mt incl ACP Sheet
with Printing letter with AMC logo as directed
by EIC. rate shall incl painting board with 2 coat
of enamal paint over one coat of anti-corrosive
Providing, Fabricating & fixing caution board of
size 1.50m x 0.60m made from ISA 40 x 40 x
mm MS angle with 2 nos. supports at back side
vertical member of of angle size 1.10m height
(inclu. 0.30m hold fast inserted in compound
wall with necessary dis-mantling and fixing with
cement concrete. The rate shall also include 14g
MS sheet of size 1.50mt x 0.60mt incl ACP
Sheet with Printing letter with logo as directed
by EIC. rate shall incl painting board with 2 coat
of enamal paint over one coat of anti-corrosive
Providing and fixing Radium sign board of size
3.00mt x 0.60 mt made from ACP sheet with
73 writing coloured reflected letter of WDS name 1.00 7400.00 Nos.
board with necessary clamp for hanging board at
pump house etc. comp as directed by EIC
Grouting with 1:3 cement, sand mortar for
anchor bolt pockets, machine bases, pipe
74 sleeves, pockets holes, etc. including 5.00 4536.00 Cmt
roughening and cleaning of concrete surfaces,
curing, etc. complete.
TOTAL ESTIMATE OF CIVIL WORK (WITHOUT GST)
Name Augmentation work with SITC of Pumping Machinery with related Mechanical,
of Electrical, Instrumentation and Civil works for Water Distribution Station At Bodakdev
Work Trilok of North West Zone of AMC.
Description Qty. Unit Amount
OFFICE FURNITURE
1 Office Table of size 1200 mm length X 600 mm 1 Nos.
Steel Office Chair
Ladder: Ladder shall be made out of light
aluminium allow of good strength. They shall be
4 of step ladder, foldable, self supportig type with 1 Nos.
sperader of metalic angles or high strength. 6,000.00
Ladder: As per S.R. No.2.(i) 3 Meter long
Ladder: As per S.R. No.2.(ii) 6 Meter long
GRAND TOTAL OF TOOLS, TEST EQUIPMENTS & SPARE PARTS
GRAND TOTAL OF TOOLS, TEST EQUIPMENTS & SPARE PARTS
Note: Above items shall be handed over to AMC before the commencement of O&M period for
new proposed Water Distribution Station at WDS of AMC.
Name Augmentation work with SITC of Pumping Machinery with related Mechanical,
of Electrical, Instrumentation and Civil works for Water Distribution Station At
Work Bodakdev Trilok of North West Zone of AMC.
Item Qty. Unit Rate Amount
Existing HSCF Pump Motor set 3 Nos.
TOTAL OF BUYBACK AMOUNT (In Rs.) -
Notes: The rate of the items shall be deducted from the capital cost of the tender and contractor
shall carryout all items.
AMC will take final decision whether to sell item or not. If AMC does not sell particular
item, the bidder will not get rebate amount of that item.
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
Volume-I_Technical Bid- Bodakdev ADB and Bodakdev Trilok WDS.pdf
Financial Bid - Bodakdev WDS.pdf
Drawings- Bodakdev WDS.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .