| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | H9₹32.3 L−₹25.4 L (43.8%)Accepted-AOC 121 MADHAV SQUAR OPP AVANTIKA COMPLEX LIMDA LANE JAMNAGAR 361001 | JAMNAGAR | GUJARAT | 361001 | H9 | Accepted-AOC Lowest Bidder | |
| 2 | H1₹58.0 LRejected-Finance | H1 | Rejected-Finance Other Than Lowest Bidder | |
| 3 | H2₹56.3 L−₹1.6 L (2.82%)Rejected-Finance | H2 | Rejected-Finance Other Than Lowest Bidder | |
| 4 | H3₹55.7 L−₹2.3 L (3.98%)Rejected-Finance | H3 | Rejected-Finance Other Than Lowest Bidder | |
| 5 | H4₹55.2 L−₹2.8 L (4.76%)Rejected-Finance C 347 ARBUDHA NAGAR ODHAV AHMEDABAD | AHMEDABAD | AHMEDABAD | GUJARAT | 382415 | H4 | Rejected-Finance Other Than Lowest Bidder |
Tender Value
₹47.5 L
EMD Value
₹95,100
Closing Date
23 Dec 2024, 6:00 pmClosed
GE (AF) Chiloda
GE (AF) Chiloda, LekawadaPatia, PO CRPF Campus, Gandhinagar (Gujarat)-382042
SPECIAL REPAIR REPLACEMENT OF WIRING, LIGHT FITTING, EARTHING AND CONNECTED WORKS FOR BLDG NO P-30, 31, P-40, PROVISION OF SECURITY LIGHT POLES AND HIGH MAST LIGHT AND PROVN OF 50 KVA DG SET AT AF STN GANDHINAGAR
2024_MES_685962_1
8214/24-25/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
GANDHINAGAR
AS PER NIT AND TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE (AF) Chiloda
₹95,100
Yes
1 Aug 2025
27 Nov 2024
25 Dec 2024
27 Nov 2024
23 Dec 2024
16 Dec 2024
Amount
Taking down carefully copper/ aluminum point wiring of any size and description (Light, fan, socket, power and Bell) including fixture and fittings such as switches, sockets, ceiling roses, lamp, holder , regulators, sockets etc, removing material for taking credit and making good disturbed surface of walls, floors, etc complete all as specified and directed.
Material and labour for point wiring for one light point controlled by one switch with using 1.5 Sqmm (nominal area) stranded copper conductor, single core, FRLS PVC insulated & unsheathed cable, 1100 volts grade drawn through concealed PVC conduit and using 1.5 Sqmm (nominal area) stranded copper conductor single core conductor, FRLS PVC insulated & unsheathed cable as in earth wire connected to common earth dolly with incl factory made modular GI/SS sheet sunken box and modular cover plate complete all as specified and directed.
All as per Serial item No. 2 here-in-before but point wiring for fan point.
All as per Serial item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on same board.
All as per Serial item No. 2 here-in-before but point wiring for 3/ 5 pin switch socket outlet combination, 5 amps on independent board.
All as per Serial item No. 2 here-in-before but point wiring for one 6 pin switch socket outlet combination, 5/15 amps (independent) with using 2.5 sq.mm (nominal area) copper PVC insulated unsheathed stranded copper conductor as continuous earth wire on independent board for one socket outlet 3 pin 15 amps.
Supply and fixing for ceiling rose surface bakelite, three terminals complete all as specified and directed.
S & F for Modular Bell push 6A 1 module complete all as specified and directed.
Supply & Fixing Modular switch 1 way 10A, 1 module complete all as specified and directed.
Supply & Fixing Modular switch 1 way 20A, 1 module complete all as specified and directed.
Supply & Fixing Modular Socket, 10A - 2/3 pin combined 2 module (with Shutter), ISI marked complete all as specified and directed.
Supply & Fixing Socket 10A/20A - 2/3 pin combined 2 module (with Shutter), ISI marked complete all as specified and directed.
Supply & Fixing Fan step regulator, 120W - 2 module , ISI marked complete all as specified and directed.
Supply & Fixing Bell Multi Music type complete all as specified and directed.
M & L for in replacement of sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sq.mm of 1100 Volts voltage rating drawn through existing non rigid PVC concealed conduit with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit.
M & L for in replacement of sub main wiring using two single core FRLS PVC insulated, unsheathed stranded copper conductor cable of size 6.0 Sq.mm of 1100 Volts voltage rating drawn through existing non rigid PVC concealed conduit with one run of FRLS PVC (green colour) insulated, unsheathed, stranded copper conductor of size 6.0 Sq.mm as earth continuity conductor complete all as specified and directed. Note : Two run of single core FRLS PVC cable with one run of earth conductor and conduit shall be measured as one unit.
Supply and fixing sheet metal enclosure, double door Metalica designer distribution board flush to wall mounting for MCB fitted with 200 Amp rated bus bars and neutral links 4 ways TPN DBs complete with making good disturbed surface of walls complete all as specified and directed.
Supply and fixing in replacement sheet metal enclosures double door Metalica designer distribution board for using MCBs suitable for single pole and neutral, 16 way with having copper bus bars suitable for 200 amps rating complete with making good disturbed surface of walls complete all as specified and directed.
All as per item No 18 here in before but 12 way.
All as per item No 18 here in before but 8 way.
All as per item No 18 here in before but 4 way.
S & F in replacement MCB Triple pole & neutral (TPN), 32 to 63 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
Supply and fixing MCB single pole & neutral (SP&N), 20 to 40 Amps, 240 volts, 10KA, ‘C’ series, with proper size lugs and connections complete all as specified and directed.
Supply and fixing MCB single pole (SP) 6 to 32 Amps, 240 volts, 10KA, ‘B’ series, with proper size lugs and connections complete all as specified and directed.
Supply & Fixing modular type 20 Amps MCB Protected three pin power socket with plug combo encloser complete all as specified and directed.
S & F for MCCB 4 Pole, 415 V, fixed type, 100 Amps with breaking capacity 16 KA with including IP 65 sheet metal encloser complete all as specified and directed.
Supply and fix exhaust fan 250mm sweep havey duty with louvers shutter, voltage 230V, 50 Hz, RPM 1200 complete all as specified and directed.
Disconnecting and taking up or down existing unserviceable/serviceable light fitting of any description and in any position fittings complete all as specified and directed.
Fixing only serviceable surface and wall mounted light fitting of any type complete all as specified and directed.
S & F Surface and wall mounted high efficiency 18 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver , Beam Angle 120° Lumen efficiency >110 Lm/W complete with all accessories internally pre wired and connection up with twin core flexible copper conductior cable incl LED light fixed on PVC box complete all as specified and directed.
S & F Surface and wall mounted high efficiency 8/10 watt LED batten, aluminium housing provided for efficient heat dissipation with polycarbonate diffuser & integrated electronic driver , Beam Angle 120° Lumen efficiency >110 Lm/W complete with all accessories internally pre wired and connection up with twin core flexible copper conductior cable incl LED light fixed on PVC box complete all as specified and directed.
S&F LED luminaire 600 mm x 600 mm, 35/36 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed.
Supply and fixing LED light fitting 1x9W/1X10W bulkhead luminaires including LED light holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
S&F surface mounted round or Square shape 18 watt 230 volts AC with high efficiency PMMA diffuser light fitting including connecting & testing complete all as specified and directed.
S&F round or square shape LED COB downlighter 12 watt 230 volts AC with swivel arrangement upto 90 degree recessed type suitable for roof ceiling including connecting & testing complete all as specified and directed.
S&F in replacement decorative tricolour (Saffron, white and green) LED AC rope light 120 LED/M IP 65, 15 meter length water proof, with adaptor suitable for 180 volt to 280 volt complete all as specified and directed by Engr-in-Charge.
S&F in replacement decorative LED AC rope light 60 LED/M, CCT - 3000K IP 65, 30 meter length water proof, with adaptor suitable for 180 volt to 280 volt complete all as specified and directed by Engr-In-Charge.
S&F in replacement LED Post top decorative aluminium die-cast aluminiumbottom housing and spun aluminium top reflector with decorative acrylic diffuser luminary -25 watt ,IP 65 , CCT 3000K suitable for 180 volt to 280 volt, long life aesthetically designed complete all as per sample directed by Engr-In-Charge.
S & F in replacement of multi stranded copper conductor of size 2.5 sqmm, 3 core PVC insulated and over all PVC Round Sheathed cable complete all as specified and directed.
M & L for laying & jointing 25 mm dia sch 40 UPVC pipe with all fittings complete to walls or laid in floors /trenches including Soil excavation not less than 0.5 mtr depth and returning filling testing complete all as specified and directed.
M & L for Boring of holes under road, pavement, hard standing by Mannualy or necessary machine for inserting of GI pipe up to 50 mm dia complete all as directed and specified.
Disconnecting the existing unserviceable SMC junction boxes and Supply and fix weather proof SMC junction box of outside size 300mm x 200mm x 105mm including MCB SPN, 32 Amps and MCB SP 6 Amps 01 Nos, 250 volts with cable gland etc. SMC junction box fixed on wall with 25 x 4mm new GI clamp complete all as specified and directed.
S&F post top lantern GI pipe pole made of 50 mm bore "medium grade" galvanised iron pipes with base plate complete with necessory drill hole and silver colour paint over a red oxide complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth lead wire 4mm dia, (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover and including dismantling/taking out of old unserviceable earthing of any position complete all as specified and directed.
Excavation in trenches n exc 1.5m wide and n exc 1.5m in depth for foundation etc (for cable, pole stay manhole etc), in any type of soil and getting out, complete all as specified and directed.
M & L for Excavation in trenches exceeding 1.5m width and not exceeding 3 m in depth and getting out in soft/loose soil for taking up/laying cable/pipe etc complete all as specified and directed.
Returning, filling in, including spreading, leveling, watering and well ramming in layers not exc. 25cm thick, etc complete all as specified and directed.
Removing excavation material n exc. 50m & deposited where directed at a level n exc. 1.5m above the starting point etc complete all as specified and directed.
Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanized steel of wire heavy duty under ground cable with aluminium stranded conductor 1100 volt grade of 16 Sqmm 4 Core laid up trenches/duct crossing through pipe/duct or fixed on pole etc with lugs, glands and testing complete all as specified and directed by Engr-in-Charge.
Supply and laying 50 mm outer dia HDPE pipe (DWC) Double wall corrugated outer surface and smooth inner wall, ISI marked and as per IS : 16205 (part-24) or latest IS 14930 (part-II), 450N compressive strength with snap fit coupler with rubber ring for underground electrical cable protection conduits Orange colour complete all as specified and directed.
Supplying and laying un-reinforced precast concrete cable cover, Class LV, Type I, flat, size 250 mm x 150mm x 40mm complete all as specified and directed.
Supply, laying and jointing HDPE pipe 40mm dia conforming to IS 4984-1995 suitable for the respective working pressure PN10 with all fittings and accessories complete all as specified and directed.
Material and labour for PCC (1:2:4) type B1 (using 20mm graded stone aggregate) as in coping including necessary form work, chamfers and finishing with using cement etc. for street light pole foundation complete all as specified and directed.
Supply and fixing hot dip galvanized Octagonal Pole of 9 meter length made of High tensile steel confirming to Galvanisation as per- IS:4759/2629 AND ASTM A123, base plate- IS-2062 and pole shaft as per - BSEN 10025, ASTM A572 with internal door openable junction box incl MCB SPN & MCB TPN -1 Nos, base plate anchor bolt and double arm street light bracket etc and also marking the pole numbers complete all as specified and directed by Engr-in-Charge.
S&F FRLS PVC insulated standed copper conductor wire of 1.5 sqmm dia, 3 core from existing junction box to light fitting complete all as specified and as directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm×6mm thick, buried directly in ground (earth pit not less than 2.25 meters deep below ground level) with top edge of the plate not less ‘than 1.5 meters below normal ground level, connected to galvanised earth strip 25 x 4 mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point complete all as specified and directed. Note: (i) Item includes the cost of 7.5 meter GI pipe for protection of earth lead.
Supply, erect /install & testing of 20 meter high galvanised mast light shaft in two sections suitable for wind speed as per IS-875 part-3, with raising lowering system pully assembly comprising, double drum winch with luminaire mounting arm, suitable to install 8 nos luminaries in symmetrical arrangement, 6mm dia stainless stell wire rope , trailing cable, connector, integral power tool motor, manual handle junction box , aviation obstruction light, lightning arrester spike and including RCC foundation comprising of the following :- a) Material & labour for construction of high mast foundation as per manufacturer drawing complete with excavation, returning & filling PCC, RCC, Reinforcement, removal & form work etc including foundation bolts from special steel along with nuts, washers, anchor plates and templates. b) Supply & fixing of outdoor type stand mounted feeder pillar box comprising incomer MCB TPN 32 Amp C series, digital multi meter, timer switch. suitable size contactor for the automatic switching ON/off the luminaries with bypass system, suitable size MCB, contactors for motor operation and raise lower push button. c) Weather proof suitable size and length PVC insulated copper conductor cable from feeder pillar box MCB to winch gear motor with lugs & from feeder pillar box MCB to individual luminary complete.
d) Weather proof suitable size and length PVC insulated copper conductor cable from feeder pillar box to high mast luminaries with lugs & MCB complete. e) Erection of the high mast pole with the help of suitable tools & plants & fixing in true vertical position. f) Supply & fix single dome aviation obstruction light LED type with all supporting accessories. g) Provision of 2 Nos GI pipe earthing with 40 mm dia GI pipe and GI earth strip 25 x 4 mm connection to high mast pole including RCC earth pit chamber and soil excavation complete.
S & F for symmetrical beam LED flood light fitting 300 Watt, IP66 protection, 230 V AC with PDC housing and toughened glass & indl LED with secondary optical lens for superior light distribution, Lumen efficiency >120 Lm/W 4 KV inbuilt and 10 KV external surge protection with driver, complete all as specified and directed.
Supply, install, testing and commissioning of outdoor type factory assembled diesel driven generating set conforming to latest CPCB IV+ with silent (acoustic) enclosure with fully wired alternator AC for ambient conditions at Gandhinagar, Gujarat for 50 KVA continuous rating at 415 volts adjustable at ± 2.5% AC 3 phase, 0.8 power factor, 4 wire, 50 Hz ± 1 %, 1500 rpm directly coupled with suitable capacity diesel engine liquid coolant based mounted on common base frame , Fuel Tank of 12 hours run adequate capacity with fuel lines, anti vibration pads, standard control , emergency stop push button & AMF panels and other accessories etc including DG set PCC platform as per manufacturer recommendation complete all as specified & directed consisting of following;- (A) Prime Mover (Diesel Engine) : Adequate capacity diesel engine of standard design consisting of enhanced fuel efficiency CRDI type, four stroke, liquid cooled technology conforming to BS 5514, ISO 3046 and IS 10000 suitable for prime duty generating set of minimum 74HP @ 1500 RPM with multi cylinders to drive independently alternator and considering rating as per site condition after generating and reducing power consumed by accessories, directly coupled through coupling having overload capacity of 10% for one hour in every 12 Hrs continuous running mounted on base frame , Genset to respond quickly & positively to sudden load additions.
Following salient features and standard accessories for safe handling & operation of engine as under:- (a) DG set should have capacity to run continuously in variable load condition for unlimited hours and should also have a 110% load capacity of 01 hours in every 12 hours of operation. (b) Air System - Inlet & Exhaust comprising (i) Dry-type paper element air Cleaner (ii) Restriction Indicator / Vacuum Indicator (iii) Intake Manifold (iv) Exhaust Manifold (v) Silencer muffler and (vi) Stainless steel Exhaust Flexible coupling (c) Cooling System comprising (i) Radiator to suit ambient conditions (ii) Cooling system piping (iii) Thermostat (iv) Pressure cap (v) Coolant Inhibitor and (vi) Engine Driven Fan. (d) Fuel System comprising (i) Fuel pump -Low pressure type (ii) Injectors (iii) Cartridge paper filters primary and secondary for Fuel. (e) Governor: - Mechanical Governor for A1 governing of engine speed from No load to full load. (f) Lub Oil System: - (i) Gear driven Lube Oil Pump, Strainer, Full-flow spin-on type Oil Filters, Oil Cooler & Oil dipstick
(g) Fuel Tank: - Draw out type integral fuel tank made of MS sheet (duly painted) of capacity min 8 hours running Ltrs capacity with provided with drain plug, air vent, inlet and outlet connection, level indicator (h) Genset Controller :- Micro-processor based Genset controllers display a host of genset parameters and controls as under:- (j) DG set monitoring features : Phase, Voltages & Currents, Frequency, Genset kVA, kW, kWh, kVAr, Power Factor , Lube oil Pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Battery charge condition, AMF feature. (ii) Diagnostic Features: Battery charging failure, Over/Under speed, Over Current, Over/Under Voltage, Over kW, Phase Seq, Phase missing, Mains Under voltage, Low fuel level, Low Lube oil Pressure, High Engine Temperature, Low/High battery voltage, Low Fuel Level, Over Crank protection, Routine maintenance indicator, Genset Test Facility, Mains Frequency.
(k) Battery - Maintenance free Battery lead acid type minimum 80AH capacity (minimum 2 year warranty ) with MS Fabricated Battery Stand and Battery Leads (C) Acoustic Enclosure (CANOPY) : Shall conform to Central Pollution Control Board (CPCB) norms of 75 dBA at one meter under free field conditions, having air inlet louvers specially designed to operate at rated load even at ambient conditions on air inlet temperature, powder coated for long lasting service life and superior finish with UV resistant powder coating to withstand extreme environments, designed to have minimum ease for unloading & shifting, i.e with central lifting facility, rust free hardware made of stainless steel, Insulation material to meet IS:8183 specifications. (D) Foundation: -PCC platform of size and type as specified in PS for mounting of DG Set. (E) POL for testing and first fill of engine oil as required for commissioning.
Supply and installed CPRI approved factory made, cubicle compartmentalised outdoor type LT Panel feeer pillar box, front and rear opening with locking arrangement, dust and vermin proof, fabricated out of 3.15 mm thick CRCA sheet with canopy and base frame & mild steel angle iron stand, over all finished with epoxy powder coating, suitable for operation on 415 Volts, 50 Hz, AC supply, including earthing stud, feeder labeling, danger plates etc. and feeder pillar box grouting in suitable size PCC foundation, and connection the existing LT UG cable or new LT UG cable with new cable lugs, gland complete all as specified and directed. The new LT panel comprising of the following switchgear & controls Incoming (a) MCCB 4 pole, 415V with thermal magnetic release adjustable setting of Capacity 250-320 Amps with ruputring capacity 36 kA - 02 Nos (b) LED RYB Phase indicater - 02 Set Out going (a) Aluminium bus bar TPN 450 Amps (b) On load change over switch 4 pole 250 amps - 01 Nos (c ) LED dispay 3 line Multimeter class 0.5 with suitable size CT ratio -01 Nos
Supply and laying 63 mm outer dia HDPE pipe (DWC) Double wall corrugated outer surface and smooth inner wall, ISI marked and as per IS : 16205 (part-24) or latest IS 14930 (part-II), 450N compressive strength with snap fit coupler with rubber ring for underground electrical cable protection conduits Orange colour complete all as specified and directed.
Supply and laying XLPE insulated PVC inner sheathed, armoured with galvanized steel of wire heavy duty under ground cable with aluminium stranded conductor 1100 volt grade of 70 Sqmm 3.5 Core laid up trenches/duct crossing through pipe/duct or fixed on panel with suitable size of glands complete and testing complete all as specified and directed by Engr-in-Charge.
Material and labour for earthing complete with galvanized steel earth plate electrode 600mm x 600mm x 6mm buried directly in ground vertically to a depth not less than 2.25 meter below normal ground level (with top edge of earth plate not less than 1.5 meter below ground level) connected to galvanized iron earth strip 32 x 6 mm (main earthing lead) by means of galvanized bolts, nuts and washers all as per shown in electrical plate No. 5 of MES Schedule Part-I with connected to earth test point main switch board with including necessary earth work and Pre- cast RCC earth pit with cover complete all as specified and directed.
Shree Builders (BID ID -3195766)
Ramdev and Sons (BID ID -3196167)
Navkar Enterprises (BID ID -3195977)
GIRNAR CONSTRUCTION (BID ID -3196271)
M/s SK Traders (BID ID -3196206)
Electricals India (BID ID -3195014)
ARTI CONSTRUCTION (BID ID -3195431)
SURESH ELECTRICALS (BID ID -3196556)
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .