| 2 | L2₹23.8 L+₹27,677 (1.18%)Rejected-Finance PLOT NO 14 NEAR BALGRAM INS SHIVAJI ROAD LONAVLA 410 401 | PUNE | MAHARASHTRA | 410401 | L2 | Rejected-Finance Not Being L1 | |
| 3 | L3₹24.0 L+₹54,345 (2.31%)Rejected-Finance TC 50 956 I VASATHY TRWA 395 THALIYAL KARAMANA PO THIRUVANANTHAPURAM KERALA 695 002 | THIRUVANANTHAPURAM | THIRUVANANTHAPURAM | KERALA | 695002 | L3 | Rejected-Finance Not Being L1 | |
| 4 | L4₹24.3 L+₹82,490 (3.51%)Rejected-Finance | L4 | Rejected-Finance Not Being L1 | |
| 5 | L5₹24.7 L+₹1.2 L (4.99%)Rejected-Finance MAGHAM RAMAPURAM LANE MUKKOLA P O TRIVANDRUM 695 044 | TRIVANDRUM | THIRUVANANTHAPURAM | KERALA | 695044 | L5 | Rejected-Finance Not Being L1 |
Tender Value
₹25 L
EMD Value
₹50,000
Closing Date
19 Oct 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
REPAIRS TO ROOF, CHAJJAS AND B/R WORKS IN CERTAIN BLDGS AT VARIOUS LOCATIONS UNDER GE (ARMY) TRIVANDRUM
2023_MES_620298_1
8131/E8
Open Tender
Civil Works
Item Rate
180 days
GE Army Trivandrum
As per NIT
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹50,000
Yes
13 Nov 2023
23 Sept 2023
26 Oct 2023
23 Sept 2023
19 Oct 2023
7 Oct 2023
24 Sept 2023 - 30 Sept 2023
Amount
Dismantling single layer Mangalore pattern or similar tiles in roofing including ridge tiles complete all as specified and directed. Notes: All works under this BOQ will be executed for buildings of height up to four storeys. Contractor shall make all necessary proper scaffolding arrangements and safety measures for labours at site.
M&L for roof tiles, Mangalore pattren, interlocking at side joints, laid dry complete all as specified and directed.
All as per Sl No. 2 here-in-before, but except tiles complete all as specified and directed. Note: Serviceable tiles obtained from item No. 1.00 here-in-before will be reused under this item.
M&L for ridge or hip tiles to suit Mangalore pattern of roofing tiles, bedded and jointed in cement mortar 1:6 complete all as specified and directed.
All as per Sl No. 4 here-in-before, but except tiles complete all as specified and directed. Note: Serviceable tiles obtained from item No. 1.00 here-in-before will be reused under this item.
Demolition of cement concrete (unreinforced) in roofs, floors (other than ground floors), beams, staircases, landing, chajjas and similar suspended work complete all as specified and directed.
M&L for providing, cement concrete type B-0, 1:2:4 using 12.5 mm graded stone aggregate in roof kerbs or mud stops, rounded or chamfered on edges complete all as specified and directed.
Dismantling wooden fillets for roof tiles battens, rails, posts, rafters, purlins etc. under 40 sq.cm in section (unframed work) complete all as specified and directed.
M&L for second class hardwood plain fillets (sectional area exceeding 13 sq.cm and not exceeding 25 sq.cm), square, rectangular or triangular in section, clean sawn, secured with nails or brads complete all as specified and directed.
All as per Sl No. 9 here-in-before, but except fillets complete all as specified and directed. Note: Serviceable wooden fillets obtained from item No. 8.00 here-in-before will be reused under this item.
Dismantling timber scantlings 40 sq. cm and over in section, unframed work, in any position complete all as specified and directed.
M&L for second class hardwood in scantlings, clean sawn complete all as specified and directed.
All as per Sl No. 12 here-in-before, but except scantlings complete all as specified and directed. Note: Serviceable wooden scantling obtained from item No. 11.00 here-in-before will be reused under this item.
Dismantling old false ceiling work including wall and ceiling boards (fibre, pulp, insulation, etc.) or insulation boards/ slabs/ blankets, any thickness complete all as specified and as directed.
M&L for 4 mm thickness non-asbestos fibre cement building boards (decorative type) fixed or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed.
S&F anodised aluminium snap grid frame work (size of grid 605x605 mm) with 35x25x1.5 mm main tee and 25x25x1.4 mm cross tee and wall angle for false ceiling complete all as specified and directed.
S&F hangers 6 mm dia. G.I. (upto 1200mm length) adjusting level fixed to roof slabs by means of ceiling cleats made out of G.I. flat 40 x 3 mm size 60mm long and expansion hold fasteners 12.5mm dia. 40mm long complete all as specified and directed.
Taking down 4 mm thickness non-asbestos fibre cement building boards (decorative type) and refixed the same or laid/ inserted to timber/ GI/ Aluminium framework with screws complete all as specified and directed.
Taking down wooden chowkats or frames with shutters not exceeding 1.5 sq.m each (without taking off shutters from the frame) complete all as specified and directed.
S&F solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with M.S. Square tube, in opening as per specification & drawing complete all as specified and as directed.
S&F Factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of M.S. tubes for top & bottom rails. M.S. frame shall be covered with heat moulded plain colour PVC ‘C’ channel having a PVC sheet strip of 20mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail & bottom rail on either side & as gap insert for top rail & bottom rail; Paneling of plain colour PVC sheet to be fitted in the M.S. frame welded/ sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement, in the frame at site as per specification & drawing complete all as specified and as directed.
S&F in repairs 100mm size butt hinges, extruded aluminium alloy with galvanised mild steel hinge pin, anodised, type C-21 complete all as specified and directed.
S&F in repairs 150mm long aluminium anodised, barrel tower bolts of extruded section complete all as specified and directed.
S&F in repairs 150mm long aluminium handles, cast type, anodised complete all as specified and directed.
Dismantling plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling wrought iron or mild steel work of any description not otherwise provided for complete all as specified and directed.
S&F steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self-tapping screws/ J-hooks complete all as specified and directed.
S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self-tapping screws/ J-hooks complete all as specified and directed.
Demolition of brick work/ PCC block/ stone wall masonry built in cement mortar and removing the debris/ rubbish to a distance not exceeding 100 mtr complete all as specified and directed.
M&L for pre-cast cement concrete block masonry type C1, 1:3:6 using 20mm graded stone aggregate with solid blocks exceeding 10 cm in width and setting in CM 1:4 complete all as specified and directed.
M&L for roughening surfaces of old concrete floor by picking old damaged tar felt/ water proof membrane any type, sweeping clean and washing down with water to remove dust, etc and brushing neat cement slurry with 3 kg of cement per sq metre complete all as specified and directed.
M&L for 25 mm thick, PCC 1:2:4, Type B-0, using 12.5mm graded stone aggregate over RCC roof as levelling course complete all as specified and directed.
M&L for rendering 10 mm thick cement plaster on fair faces of brick work/ concrete surfaces in cement mortar 1:3, mixed with water proofing compound @ 3% by the weight of cement, finished even and smooth without using extra cement complete all as specified and directed. Note: Water proofing compound shall be measured and paid separately.
M&L for APP modified water proofing membrane thickness not less than 4mm and weighing not less than 4.50 Kg/ Sqm reinforced with non-woven polyester, matt black finished (weight not less than 150 gms / sqm), laying by torch application including minimum 100mm overlap over compatible primer @ 0.40Litre/sqm and finishing with solar reflective Bituminous aluminium paint 100 gms /sqm complete all as per manufacturer's instructions and specified & directed.
Taking down cement plaster on brick or stone walls, etc. including raking out joints, hacking for key, scrubbing down with water, etc. complete all as specified and directed.
M&L for rendering in two layers as 5 mm thick with cement mortar (1:4) mixed with water proofing compound @ 3% by the weight of cement over rendering 10mm thick with cement mortar (1:6) on fair faces of brick work in external surfaces of wall complete all as specified and directed. Note: Water proofing compound will be measured and paid separately.
M&L for 5mm thick rendering in cement mortar 1:3 on fair faces of concrete surfaces as in ceiling finished even and smooth without using extra cement etc complete all as specified and directed.
M&L for rendering 10 mm thick cement plaster on fair faces of brick work/concrete surfaces in cement mortar 1:6, finished even and smooth without using extra cement complete all as specified and directed.
Supply only integral water proofing compound complete all as specified and directed.
M&L for applying two or more coats of 100% Premium acrylic emulsion paint having VOC less than 50 gm/litre and UV resistance as per IS 15489:2004, Alkali & fungal resistance, dirt resistance exterior paint of required shade (Company Depot Tinted) with silicon additives @ 1.43 litre/ 10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/ 10 sqm over new surfaces complete all as specified and directed.
M&L for preparation of newly plastered wall surfaces and applying 2mm thick wall care putty and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and directed.
M&L for preparation of newly plastered ceiling surfaces and applying two coats of distemper oil emulsion over a coat of primer complete all as specified and as directed.
S&F 110mm bore PVC (SWR) pipes single socketed, including bend/ joint etc. all fittings, in any length with rubber ring joints laid in trenches or in floors or fixed to walls including taking down old damaged cast iron pipes/ PVC pipes (including all fittings), burning out joints etc to facilitate dismantling old serviceable fittings/ pipes laid in trenches, floors or fixed to walls, including necessary earth work, demolition of PCC/ brick work and making good to match with existing surfaces, including necessary scaffolding complete all as specified and directed.
All as per Sl No. 44.00 here-in-before, but 160mm bore PVC (SWR) pipes complete all as specified and directed.
Cutting/ cleaning small trees, saplings, shrubs and under growth complete roots from brick walls, chajjas etc including taking out complete roots from inside walls/ chajjas and making good surfaces in cement concrete 1:2:4 type B1 or in cement mortar (1:4) to match the existing surfaces complete all as specified and directed.
M&L for clearing vegetation/ shrubs along with all the debris of leaf from roofs, sunshades, etc and making surface clean, making good with plaster in CM 1:3 or PCC 1:2:4 (12.5 mm graded aggregate) as per the site requirement/ condition complete all as specified and directed.
M&L for arresting leakage in the RCC/ sheet/ tiled roof with approved sealant or cement and making the surface good and clean including making necessary scaffolding arrangement up to height four storey as per the site requirement/ condition complete all as specified and directed.
Disconnecting existing tank capacity 500 Ltrs, setting aside (or lowering if required) for repairs, cleaning, etc. and hoisting if required reconnecting and re-fixing in position after cleaning and removing all scale and dirt, etc, from tanks and from mouths of circulating pipes etc complete all as specified and directed.
M&L for cutting out existing cracks in concrete surfaces/ masonry walls/ RCC slabs, forming a 'V' groove of 25x40 mm size, cleaning the groove thoroughly with air blower, priming the groove with polymer/ bituminous primer using spray gun/ brush, filling the groove with putty type crack filler mixed in proportion including sealing coat as per manufacturer's instructions etc complete all as specified and directed.
Taking down existing aluminium door frame with shutters exceeding 1.50 sq.m and not exceeding 4.00 sq.m each and refixing in same opening after carry out necessary repair work including easing and adjusting and also refixing builders hardware as required including renewal of unserviceable screws, etc complete all as specified and directed.
VIJAYA ENTERPRISES
Satheesh Kumar
SHILPA ENGINEERS AND CONTRACTORS
B.LAMBODHARAN
KEERTHI CONSTRUCTIONS
DJ GROUP
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .