Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹12.4 LAccepted-AOC GALI NO 4 GAUSHALA ROAD VIKASH NAGAR RAMGARH CANTT RAMGARH JHARKHAND 829122 | RAMGARH CANTT | RAMGARH | JHARKHAND | 829122 | L1 | Accepted-AOC Bid is lowest and reasonable | |
| 2 | L2₹13.1 L+₹25,881.55 (2.01%)Rejected-AOC | L2 | Rejected-AOC Bid is not lowest and reasonable | |
| 3 | L3₹13.4 L+₹53,270 (4.14%)Rejected-AOC | L3 | Rejected-AOC Bid is not lowest and reasonable |
Tender Value
₹15 L
EMD Value
₹30,000
Closing Date
6 Jun 2023, 6:00 pmClosed
GE RAMGARH
GE RAMGARH CANTT
REPAIR MAINTENANCE OF DG SET AND CHEMICAL DOZER AT RAMGARH CANTT UNDER GE RAMGARH CANTT
2023_MES_582068_2
8300/3156/E8
Open Tender
Civil Works
Item Rate
180 days
GE RAMGARH
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE RAMGARH
₹30,000
Yes
23 Aug 2023
13 May 2023
8 Jun 2023
13 May 2023
6 Jun 2023
22 May 2023
Amount
Comprehensive maintenance of DG set of capacity 25-50 KVA with cleaning, oiling, greasing, minor repairs of any kind to diesel engine & AC generator including replacement of spare parts like clamps, tappet cover gasket, water pump gasket, radiator gaskets, minor repair of self starter, alternator/dynamo, adjustment of carbon brush of any type, adjustment of AVR & Tappets, replacement of battery brass terminal, repair to battery post, replacement of toggle switches, reparing to wiring in control panel of Gen set using existing size of copper wire, cleaning of diesel storage tank, replacement of level indicator, outlet valves, Piston ring set, Small end bush for Connecting rod, Large end bearing and bolt for connecting rod, Fuel filter single bowl with 'O ring complete, Fuel pipe feed pump to filter, Fuel pipe filter to FI pump, Lub oil filter element with sealing ring, Fan belt, replacement of required quantity of coolant & distilled water in radiator assy & battery respectively as required complete along with calibration of FIP if necessary, repair of radiator assembly, repair of self starter, alternator, DC control panel AMF Panel, spray painting to DG Set once in a year etc all as specified & as directed. Note :- (i) Spares parts ,if required for replacement will be measured & paid seperatly under respective item of BoQ. (ii) Each maintenance job shall be covered period of 12 Months
Comprehensive maintenance of DG set of capacity 82.5 KVA to 125 KVA with cleaning, oiling, greasing, minor repairs of any kind to diesel engine & AC generator including replacement of spare parts like clamps, tappet cover gasket, water pump gasket, radiator gaskets, minor repair of self starter, alternator/dynamo, adjustment of carbon brush of any type, adjustment of AVR & Tappets, replacement of battery brass terminal, repair to battery post, replacement of toggle switches, reparing to wiring in control panel of Gen set using existing size of copper wire, cleaning of diesel storage tank, replacement of level indicator, outlet valves, Piston ring set, Small end bush for Connecting rod, Large end bearing and bolt for connecting rod, Fuel filter single bowl with 'O ring complete, Fuel pipe feed pump to filter, Fuel pipe filter to FI pump, Lub oil filter element with sealing ring, Fan belt, replacement of required quantity of coolant & distilled water in radiator assy & battery respectively as required complete along with calibration of FIP if necessary, repair of radiator assembly, repair of self starter, alternator, DC control panel AMF Panel, spray painting to DG Set once in a year etc all as specified & as directed. Note :- (i) Spares parts ,if required for replacement will be measured & paid seperatly under respective item of BoQ. (ii) Each maintenance job shall be covered period of 12 Months
Comprehensive maintenance of DG set of capacity 250 KVA with cleaning, oiling, greasing, minor repairs of any kind to diesel engine & AC generator including replacement of spare parts like clamps, tappet cover gasket, water pump gasket, radiator gaskets, minor repair of self starter, alternator/dynamo, adjustment of carbon brush of any type, adjustment of AVR & Tappets, replacement of battery brass terminal, repair to battery post, replacement of toggle switches, reparing to wiring in control panel of Gen set using existing size of copper wire, cleaning of diesel storage tank, replacement of level indicator, outlet valves, Piston ring set, Small end bush for Connecting rod, Large end bearing and bolt for connecting rod, Fuel filter single bowl with 'O ring complete, Fuel pipe feed pump to filter, Fuel pipe filter to FI pump, Lub oil filter element with sealing ring, Fan belt, replacement of required quantity of coolant & distilled water in radiator assy & battery respectively as required complete along with calibration of FIP if necessary, repair of radiator assembly, repair of self starter, alternator, DC control panel AMF Panel,spray painting to DG Set once in a year etc all as specified & as directed. Note :- (i) Spares parts ,if required for replacement will be measured & paid seperatly under respective item of BoQ. (ii) Each maintenance job shall be covered period of 12 Months
Following spares parts for top overhauling/maintenance of DG set 25 KVA to 250 KVA:-
Supply only Fuel feed pump
Supply only Main bearing set of 5
Supply only Piston with piston pin, circlip
Supply only Connecting rod
Supply only Cylinder liner with joint ring
Supply only Complete gasket set
Supply only head gasket
Supply only Inlet & exhaust valve
Supply only High pressure pipe complete set
Supply only Fuel filter element pre & Micro
Supply only Lub oil cooler
Supply only Set of hose pipe for water inlet & outlet connection with clamp
Supply only Thermostate element
Supply only Anti vibration mounting of radiator
Supply only Alternator 12V assy
Supply only Starter 12 V
Supply only Silencer mufler of suitable size
Supply only Diapharm coupling
Supply only Stop solenoid 12 V
Supply only Solenoid valve 12 V
Supply only Banded wrapped belt 21A 52
Supply only Exhaust air buffle
Supply only Non return valve
Supply only Nozzle
Rewinding of MX unit with suitable size of super enamelled copper wire including heating vernishing providing required insulating materials for alternator cap 25 to 250 KVA complete all as specified and directed.
Supply only of carbon brush holder of alternator 25 to 250 KVA
Supply only of rectifier of alternator 25 to 250 KVA
Supply only of AVR suitable for 25-50 KVA DG set complete all as specified and directed
Supply only of of of AVR suitable for 82.5-250 KVA DG set complete all as specified and directed
Filling only of Engine oil 20W40 210 ltr to top up/ refilling of all DG set as per the direction of Enger-in-charge.(Make Gulf/Castrol/Volvalin)
Supply only of new Air cleaner complete all as specified and directed
Supply only of battery 180 AH, 25 plate with initial Charger Specific gravity 12.60 of 12 volts complete all as directed by Engineer-in-Charge. Make:- EXIDE/Amron or equivalent
Supply only of battery 150 AH, 25 plate with initial Charger Specific gravity 12.60 of 12 volts complete all as directed by Engineer-in-Charge. Make:- EXIDE/Amron or equivalent
Dismantling of 7.5 HP capacity air compressor and carrying out repairs by replacing worn out/ damaged parts, over hauling and providing major parts such as piston ring set, guide valve, valve guide screw, bush lining, pin gudgeon, bearing ball, oil seal, seeger ring, ring locking, suction filter, pressure switch, pressure gauge, delivery pipe, gasket set etc. complete with all accessories as per site requirement including assembling, testing, commissioning all as directed.
Disconnecting the defective/burnt alternator from the engine and removing it from the baseframe and shifting it to the workshop, removing rotr and cutting the field copper winding or armature winding and cleaning the slots complete for rewinding and using super enameled copper wire, varnishing and drying using three coats of insulating varnishing and reassembling the motor after repairs/ re setting complete re installation at site including transportation complete of capacity 100 KVA DG Set complete all as specified by Engineer in charge.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 35 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 50 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 70 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 95 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply, laying , jointing & testing LT under ground cable XLPE insulated, screened ,PVC bedded, galvanised steel strip or wire armoured, electric power cable ( heavy duty) with standard aluminium conductor , 1100 Volts grade of cross sectional area 120 Sq mm 3.5 core including taking down old unserveciable cable complete all as specified and directed.
Supply and laying GI pipe 80 mm dia light grade with all necessary fittings for cable protection including taking down old unserveciable pipe complete all as specified and as directed.
Supply and laying GI pipe 100 mm dia light grade with all necessary fittings for cable protection including taking down old unserveciable pipe complete all as specified and as directed.
Supply and laying GI pipe 150 mm dia light grade with all necessary fittings for cable protection including taking down old unserveciable pipe complete all as specified and as directed.
Excavation in trenches in soft & loose soil not exceeding 1.5 metre deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes,foundations, shafts, well, cesspits, manholes etc. complete all as specified and directed.
Returning, filling in including spreading, leveling, watering and well ramming in layers of not exceeding 25 cm thick after the cables & pipes etc. are laid, jointed & tested and foundations complete all as specified and directed by Engineer-in-Charge.
Removal of surplus excavated spoil not exceeding 50 Mtr distance and depositing where directed by Engineer-in-Charge at a level not exceeding 1.5 m above the starting point complete all as specified.
Supplying and laying un-reinforced pre -cast concrete cable cover class LV, Type - 1 , flate, size 250 mm x 150 mm x 40 mm complete all as specified and as directed by the Engineer-in-Charge.
Material and labour for sand cushioning for protection of underground cable, consolidated and compacted with clean dry sand all as specified and as directed by the Engineer-in-Charge. (Note : The depth of sand shall be measured after punning only)
M&L for plain cement concrete 1:4:8, type D-2 (using 40 mm graded crushed stone aggregate) as in sub base of flooring, foundations,filling & mass concrete etc complete all as specified and directed.
Repairs and maintenance of Chemical Dozing pumps of any make and capacity including replacement of defective / unserviceable suction/discharge pipe 3/8", duck bill & connecting nut 3/8" etc after taking out the old ones with new ones complete : Note :-(i) Cost of minor repairs / replacement of minor spares such as nuts, bolts, washers etc. are deemed to be included in the unit quoted rates. (ii) The cost of transportation to nearest workshop & back after repair if necessary is deemed to be included in the unit quoted rates.
Following spares / components for chemical Dozing pumps:-
Supply only Pump tube
Supply only Injection check valve
Supply only Foot valve 3/8"
Supply only Connecting Nut with adapter 3/8"
Supplying, installation, testing and commissioning of Area alarm (3 gas) including taking down of existing Area alarm complete all as specified and as directed. Make: V-tech/ Ingersoll/ Ahuwalia
S&F Oxygen alarm and valve system with low pressure gauge including taking down old unserveciable Oxygen alarm and valve complete all as specified and as directed.
S&F 15 W high efficiency Solar street light made with mono crystalline solar PV module, Lithium Ferro Phosphate battery with in-built BMS technology, high efficacy LED, MPPT solar charge controller and Aluminium extruded body & specially programmed to automatically control the dimming and brightness of light.taking down old unserveciable Solar street light complete all as specified and as directed. Make : Havells Cat part No. SOLAR AIO 15 W or its equivalent.
M&L for repair and maintenance of solar water heater of 100 Ltr capacity with the replacement of following connected accessories if necessary including taking down complete all as specified and directed :
Solar water heating element of capacity 3 KW
Solar water heating Thermostat
Cleaning and washing of solar water heater tank with chemical hard water stain remover of make Tetra Clean
Cleaning and washing of solar panel (4 x 150 W solar PV module) with chemical of hard water stain remover i.e. Tetra clean.
S&F for Gun metal , globe or gate valve, 25 mm with iron wheel head, screwed both ends for iron pipe and fixed complete including taking down old existing unservicable one, complete all as specified and as directed.
M&L for sub main wiring two single core 4.0 sq mm PVC insulated FRLS multistranded copper conductor and one run of 4.0 sq mm PVC insulated unsheathed FRLS multistranded copper conductor cable for earth wire drawn in & including surface conduit rigid non metallic PVC conduit medium grade with fittings (ISI marked) not less than 20 mm dia, complete and making good disturbed surface wall including taking down of existing submain wiring complete all as specified and as directed. Note: 2 runs of 4 sqmm cable and 1 run of earth wire 4 sq mm and conduit pipe shall be measured as one unit length.
AASHIRWAD ENTERPRISES
M/S Akash Enterprises
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .