Executive Engineer
Electric Distribution Division Baroo Kargil
Supply, Installation, testing and Commissioning for Creation of Different capacity sub- stations along with HT/LT network at Khurbathang and Stara Zanaskar Agriculture farm Under District capex 2025-26
2025_PDNRE_16693_1
E NIT 41 OF 2025-26
Open Tender
Electrical Works
Turn-key
30 days
zANASKAR AND kHURBATHANG
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
Account No 0096010200000064 IFSC Code JAKA0KARGIL)
₹41,000
17 Jul 2025
28 Jun 2025
11 Jul 2025
28 Jun 2025
10 Jul 2025
6 Jul 2025
Amount
SITC of
11/0.433kV, 3-phase 200 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, with LV Cable Box having detachable Aluminium Gland plate
11/0.433kV, 3-phase 63 kva Distribution Transformerswith Bimetallic Terminal Connectors Energy Level-2, with LV Cable Box having detachable Aluminium Gland plate
Gapless Surge Arrestor,9 kV ,10 kA ,LA with polymer housing, Stn. Type
11kV GO, AB Switch 3-Phase, 3-Pole, 200 Amp,Vertical Type
11 kV Horn Gap Fuse Set 3 Phase 200A
95 mm² Single Core ,1.1kV Grade, PVC Insulated Stranded ConductorFRLS type
9 Mtr. Long Pole,ST-410 SP33)
33kV Polymeric composite Disc Insulator 36kV,min failing load 70kN, Lighting Impulse 170kV Positive and 180kV Negative,creepage distance 900mm
GI Channel/Angle/Flat of sizes including clamps
Galvinized Nuts and Bolts.
Chemical Earthing of substation --Excavation of earth pit of dia 650 mm & depth 3000 mm, installation of Earthing pipe of 40 mm Nominal bore & 4mm wall thickness & length 2.5 mtr long as Per IS 1239.GI Strip for neutral earthing of size 25 mm x 3 mm for
33kV Polymeric composite Pin Insulator 36kV, 10kN, Lighting Impulse 170kV Positive and 180kV Negative, creepage distance 900mm
LT Distribution Box for 63 KVA Sub- Station With MCCB and SFUs for outgoing
LT Distribution Box for 200 KVA Sub- Station With MCCB and SFUs for outgoing
Wedge connectors/PG Clamps
Danger Plates with Clamps
GI Barbed Wire for Anti Climbing
Cement bottoming 1:2:4 mix as per REC standards .5cum/pole
Painting of Poles Red Oxide
Painting of Poles Aluminium Paint
Sundry items like almunium lugs,jumpers,binding tape etc
9 Mtr. Long Pole( ST-410 SP33)
GI V cross-arm with top Bracket including clamp suitable for 33KV Pin & Disc insulators(sample available with department)
30 mm² ACSR Conductor
PG Clamps for 30Sqmm ACSR Conductor
11 KV Tr- vector Energy Meter for 200 KVA DTR with suitable Ct/PT
SITC of 3Ph, 4W prodigy Energy meter for 63 KVA DTR
Galvanized Nuts and Bolts
Danger Plates with Clamps
Anti-Climbing Device with Clamps
Earthing Complete by GI Pipe 40 mm or GI Rod 20mm 2.5 mtr long through GI Strip.
Red Oxide
Aluminium Paint
Cement bottoming 1:2:4 mix as per REC standards .5cum /pole
8 Mtr. Long Pole( ST-410 SP15)
Suspension clamp with i- Hook
50 sq mm LT AB Cable (3x50+1x16+35 sq mm)
LT Sub Distribution Box
Muki Clamp
GI Channel with clamps
30Sqmm ACSR Conductor
16KN Polymer pin Insulator
Galvanized Nuts and Bolts
Earthing Complete by GI Pipe 40 mm 3mtr long through GI Strip 25x3mm.
Red Oxide
Aluminium Paint
Danger plates
Cement bottoming 1:2:4 mix as per REC standards .45cum /pole
SAIA ELEKTRO (BID ID -163114)
M/S MANZOOR AHMAD (BID ID -163084)
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .