Loading…
Loading…
Tender Value
₹9.0 Cr
EMD Value
₹9.0 L
Closing Date
24 Sept 2026, 6:00 pmClosed
Ahmedabad Municipal Corporation Central Zone
CONSTRUCTION OF COMMUNITY BUILDING AT T. P. S. No. 5 (City Wall Improvement) (Section – 7) Final Sanc., F. P. No. 26, At: Dariyapur - Kazipur, Taluka: City, District: Ahmedabad, near dariyapur gate dariyapur ward central zone, Ahmedabad
345096
09/2026-27
Open
Miscellaneous Works
Works
Ahmedabad
1 document required · 1 mandatory
₹12,000
municipal commissioner
₹9.0 L
15 Sept 2026
15 Sept 2026
15 Sept 2026
24 Sept 2026
15 Sept 2026
S.No Qty Item Unit Rate Amount
A EARTHWORK AND ALLIED WORK
1 5.00 Demolition and disposal of unserviceable materials
with all leads and lifts for Brick masonary. Rate
also includes necessary tools, scaffoldings and all
safety measures required for the same, including all
leads and lifts. Cmt. 544.95
2 10.00 Demolition and disposal of unserviceable materials
with all leads and lifts for RCC work.Rate also
includes necessary tools, scaffoldings and all safety
measures required for the same, including all leads
and lifts. Cmt. 1047.38
3 100.00 Empty boring holes 3.50 mt depth in ordinary soil
and getting out the soil and disposing the surplus
excavated eart within 50 mtr lead for a) 300 m.m.
dia. Pile Each 1509.00
4 20.00 Extra for under reaming inside the bore Holes for
under reamed piles of following Diameter. (a)
mm. Each 642.30
5 30.00 Extra above over item of boring to the rates of bore
holes of 3.5 mtr if bore are made deeper than
mtr. For a) 300 mm dia. Rmt. 539.34
6 970.00 Excavation for foundation upto 1.50 Mt depth
including sorting out and stacking useful materials
and disposing off the excavated stuff upto
Meters lead (B) Dense or hard soil. Cmt. 259.14
7 970.00 Excavation for foundation 1.50 Mt to
3.0 Mt. depth including sorting out and stacking
useful materials and disposing off the excavated
stuff upto 50 Meters lead (B) Dense or hard soil.
8 323.50 Excavation for foundation 3.0 Mt. to
5.00 Mts. depth including sorting out and stacking
useful materials and disposing off the excavated
stuff upto 50 Meters lead (B) Dense or hard soil.
9 100.00 Filling available excavated earth (excluding rock)
in trenches, plinth, sides of foundations etc. in
layers not exceeding 20 cm. in depth, consolidating
each deposited layer by ramming and watering etc.
complete. Cmt. 129.10
10 10.00 Filling in foundation and plinth with murrum or
selected soil in layers of 20 cm. thickness including
watering, ramming and consolidating etc. complete. Cmt. 286.20
11 10.00 Sand filling with sand as approved by Architect in
plinth / under floor / elsewhere including watering,
ramming, consolidating and dressing to the
required grades and levels as directed by Clerk-of-
Work. Cmt. 455.63
12 2025.0 Anti-Termite System: Providing and laying of
0 permanent piping technology anti-termite
treatment before flooring work by installing LLDP
(Low linear density polyethylene) tube of 8 mm
O.D. & 6.4 mm 1.D. with inbuilt pressure
compensation chip every 30 cm interval in the tube,
having working pressure of 2 Kg/cm2 and release
rate of 1.9 Itr/hour fixed by P-clips and nails. The
LLDP pipe shall be installed at the entire periphery
of the building and at internal network of building
at a depth of 20 to 200 mm under floor at every 2 to
3 mtr. c/c distance (adjusted as per building layout
)& Ends of loop pass through a PVC elbow of
minimum 32 mm ID at junction box of wall and
floor level, entering into a steel reinforced grooved
flexible pipe of minimum 22 mm ID leading into
junction box and the loops shall terminate in
junction boxes & test every junction during
injecting chemicals for termite control treatment.
The anti termite chemical Imidacloprid 30.5% SC
mix as per IS-6313 (part III) shall be injected by the
pressure pump diluted with water @ 10.5 ml/5 ltr of
water at the rate of 2 Kg/sq.cm @ 5 Ltr/SMT. The
contractor shall submit approved line plan for
piping system and junction boxes dully approved by
Engineer-in-Charge with bond of 5 year
warranty.(i)Anti Termite chemical injected area
(Chemical injecting incl. labour cost) Sq. mt 133.00
13 2025.0 Carrying out timber treatment to all woodwork,
0 including drilling holes and spraying oil-based
chemical solution on the surface of timber work for
termite control, including labor and material etc.,
complete. Using Chlorpyriphos20 EC as per
2013 Part III (1% concentration by mass) is
recommended: one litre of chemical emulsion
diluted with 19 litres of kerosene. Total diluted
concentration will be 20 liters, inclusive of 1 liter
chemical emulsion application in drilled holes and
0.75 / Litre chemical per one Sqmt two coat on
wood surface not protected by paint or varnish. Sq. mt 54.98
14 3100.0 Applying general insecticide pest control treatment
0 to floors, cupboardsetc including labour materials
etc. complete. Using Imidacloprid 30.5 SCas Per IS
6313 part -II( (0.075% concentration by mass) is
recommended 10.5ml chemical diluted with 5 liters
of water application 0.5 litre chemical /Sqm of
surface is recommended as per I.S. Sq. mt 88.40
15 600.00 Carrying out plinth treatment to post
construction / existing structure by spraying
chemical solution for termite control treatment,
including labour and material, consistent with I.S.I
specification. Using Chlordene and Chlorpyrifos
EC. As Per 6131_paret-II Concentration Weight
one percent is recommended i.e one litre 20 EC
chemical emulsion with 19 liter give 1 %
concrentration, inclusive of one litre chemical
emulsion application at the rate of 5 Litre chemical
/ Sqm of surface is recommended as per I.S Sq. mt 104.90
16 2690.0 Carrying out wall treatment for termite control,
0 including spraying with chemical solution in oil
base, including labour and material. Using
Chlorpyriphos 20 ECAs per IS 6313 part- II (1%
concentration by mass) is recommended i.e one litre
chemical emulsion diluted with 19 litres of oil base.
Total solution will be 20 liters inclusive of one liter
chemical emulsion application at the rate of
litres chemical / Sqm of surface is recommended as
per I.S. Sq. mt 37.34
17 Conveyance charge of lime , murrum, building
rubbish, earth manure or sludge, and excavated
earth and fly ash
and any kind of debris etc. complete. No dry factor
for this item shall be calculated.
a 800.00 a) Upto lead of 5 Kms. Cmt. 235.51
b 300.00 b)Conveyance Charge (Extra Rate) above
5.00 Km and Up to 10.00 Km. Cmt. 350.00
B CONCRETE AND ALLIED WORK
18 100.00 Providing and laying cement concrete 1:3:6 (1-
Cement : 3 - Coarse aggregate : 6-Hand broken
stone aggregates 40 mm nominal size) and curing
complete excluding formwork in (A) Foundation
and plinth. Cmt. 4700.00
19 550.00 Providing and laying in situ controlled Reinforced
Cement Concrete of Mix M20 grade using cement
of OPC and 20mm and down size machine crushed
black trap of approved coarse aggregate and fine
aggregates confirming to IS: 383 - 2007, by
concrete batch mix plant, weight batch machine
mixed and machine vibrated design mixed concrete,
including design of concrete mix and shall be
confirming to latest IS : 456, IS : 10262 :
SP23 & SP24 with minimum cement content of
Kg per CUM of concrete and if necessary adding
admixtures in recommended proportions as per IS :
9103 as retarding admixture to retard setting of
concrete and or water reducing admixture to
maintain workability with reduced amount of water
and to improve durability without impairing
strength of concrete for any type, any shapes and
any sizes of reinforced cement concrete structural
members and mass concrete such as..........for
foundation, raft, retaining wall, column, pedestals,
ground/plinth beam, beam, suspended slab, coping,
wall lintel , weather shed, chajjas, lofts, steps and
waist slab of staircase, platform, canopy, peragolas,
parapet, dropwall, window cills, mullions, facia,
fins, gutter, bed block, ramp, overhead and under
ground water tank........etc., as shown in the
drawings and specifications for all sectionc in all
position for including mixing, transporting,
pumping and placing (pouring), hoisting, necessary
scaffolding, vibreting , finishing evenly, watering,
levelling, roughening and or hacking concrete at
construction joints, leaving pockets and holes,
keeping drip moulds, grooves, including curing,
testing etc.with rigid and waterlight centering and
shuttering as ordinary formwork using steel /
plywood shuttering materials for horizontal, vertical
and inclined membe of rectangular, square, round,
hexagonal, octagonal or curved shape, including
necessary propping, scaffolding, bracing, shorig,
strutting, bolts, fastener nails etc; and keeping the
same in position during and after concreting and
careful stripping / careful removal of the same at
and up to appropriate time, applying approved
shuttering oils and by approved manner will prior to
placing the reinforcing steel in position to ptevent
the adhesion of concrete to form work etc. complete
and as directed and specified by PMC /
ARCHITECT / ENGINEER.
(1) The Concrete Mix Design shall be done by the
CONTRACTOR in testing laboratory approved by
PMC / ARCHITECT / ENGINEER with the
Maximum Water Cement ratio shall be limited to
(2) The concrete design mix shall be of without
/ using of Admixtures / Additives to achieve the
desire strength etc; and it shall be not paid extra.
(3) Rate EXCLUDES providing and installing
Reinforcement Steel, conduits, sleeves and inserts
& form work-Shuttering and Centering.
(4) If in Concrete Mix Design Fly Ash is allowed to
use with OPC cement - use of Fly Ash as maximum
25 % by weight of total cementatious material to
replace by Fly Ash conforming to IS : 3812 -
(Latest), than Price Difference between OPCement
and Fly Ash shall be discounted / adjusted in next
bill. Cmt. 11500.00
20 273.10 -Do- as per above item but from below ground
level to Ground Floor Slab level Cmt. 12500.00
21 353.00 -Do- as per above item but from Ground floor Slab
to First Floor Slab level Cmt. 13500.00
22 307.00 -Do- as per above item but from First floor Slab to
Third Floor Slab level Cmt. 13500.00
23 313.00 -Do- as per above item but from THird floor Slab
to Fifth Floor Slab level Cmt. 13500.00
24 790.25 Extra for M
25 1005.8 Extra for M
26 142 Providing TMT Bars FE- 550 reinforcement for
000.00 R.C.C. work including bending, binding and
placing in position complete upto floor two level. Kg 75.46
27 Providing, laying and fixing in position galvalume
pre painted and pre coated (PPGA) trapezoidal
profile sheets (size, shape and pitch of corrugation
as approved by PMC / ARCHITECT / ENGINEER)
with special male / female side laps and anti
siphoning feature at male and to prevent leakage
made from high tensile strength - 345mpa / 500mpa
GALVALUME steel and AZ-150gsm Zincalume
coating to total on both side as per ASTM
(55% aluminium + 43.5% zinc and 1.5% silicon)
having sheet 0.55mm TCT at top and base metal
thickness 0.48/0.5mm including colour coating of
20 micron finish coat over 5 micron primer coat on
exposed side and back coat of 5 microns over a
primer coat of 5 microns and having protective gard
film of 25 micrones to avoid stretches while
handling the sheet and upto erection process for
roofing and side clading, approved make and
approved shade, for roofing at all levels and heights
including cutting sheets and drilling the holes with
side laps as required and end laps 150mm to
200mm including fixing by self tapping and self
drilling 8 mm dia x 55mm long SDST screw of
'BUIDEX' orcorroshield make as per AS -
class-3 with EPDM seal, washer of 25mm dia 3mm
thick bitumen washer with 6mm central hole to
form water proof joint etc. and using templates as
suggested by manufacturer to ensure proper side
laps for any pitch in horizontal and verticle or
curved surface, etc. complete and as directed and
spaecified by PMC / ARCHITECT / ENGINEER.
a 480. do as per above item but for roofing monitors from
00 0.50 mm thick Sq. mt 650.00
b 56.0 do as per above item but for roofing monitors from
0 0.50 mm thick Rmt. 775.00
C MASONARY AND PLASTER WORK
28 5.09 Brick work using common burnt clay building
bricks having crushing strength not less than
kg/Sq. cm. in foundations and plinth in cement
mortar 1:5 (1 cement :5 fine sand) for conventional
type bricks. Cmt. 4011.66
29 50.0 Extra rate over above item 37 Brick work using
0 common burnt clay building bricks having crushing
strength not less than 35 kg/Sq. cm. in cement
mortar 1:6 (1 cement :6 fine sand) for
superstructure upto floor three level height. For
conventional type bricks. (a) For Superstructure
above plinth level upto floor two level
(B) Conventional. Cmt. 4284.21
30 170. Extra rate over above item 37 and 38 Brick work in
00 super structure above floor two level over and
above the above item of brick work in
superstructure (B) Conventional. Cmt. 4324.00
31 50.0 Half Brick masonary in common burnt clay
0 building bricks having crushing strength not less
than 35 Kg/Sq. Cm in Cement Mortar 1:4 (1-
Cement : 4- Coarse Sand) in superstructure above
plinth level for any level and height.
(B) Conventional Bricks. Sq. mt 633.99
32 269 Providing and applying double coat waterproof
0.00 cement plaster (mala finish) on internal surfaces in
two layers, including surface preparation, mixing
approved integral waterproofing compound, curing,
scaffolding, etc. complete.First coat: 10–12 mm
thick in CM 1:4 with waterproofing
compoundSecond coat: 6–8 mm thick in CM 1:3
with waterproofing compound (mala
finish)Finished smooth and even, true to line and
level. Sq. mt 366.12
33 156 Providing and applying 15–20 mm thick stucco
7.00 plaster in cement mortar (1:3 / 1:4) in two coats,
including surface preparation, scaffolding, finishing
to the desired texture, curing, and all leads & lifts
complete as per specifications. Sq. mt 950.00
34 156 Providing 20 mm thick double coat mala / sandface
7.00 cement plaster on brick/ concrete work for
plastering comprising of base coat of 12 mm thick
cement plaster in cement mortar (1 Cement :
Coarse Sand) in rough finishing and 8 mm thick top
coat of cement mortar 1:2 (1 Cement : 2 Coarse
Sand) finished with trowel including scaffolding
curing etc. complete. Sq. mt 394.02
35 150 Providing and fixing 23 cms wide chicken mesh
0.00 jaali with nails & then application of 15 mm plaster
on R.C.C. &Masonary joints as per directed of
Engineer in Charge Sq. mt 210.00
D STRUCTURE STEEL AND ALLIED WORK
36 143 Providing, Fabricating, Transporting and Erecting
10.00 in position at all levels as per drawing welded /
bolted / riveted steel structures with field bolting /
riveting / welding / drilling whebever necessary and
finally full welde after completting erecting work,
applying one coat of rust remover one coat of anti -
corrosive red oxide paint or yellow zinc chromate
and three or more coats of approved make and
shade flat / enamle / aluminium paint to give even
shade etc, as directed and specified with necessary
gusset plates, base plates, base plates, battened
plates, cleats, etc. complete as per design and as
directed and specified by PMC / ARCHITECT /
ENGINEER. (a) Gusset plates will be measured
and actual and paid for.
(b) Weight of bolts , nuts, washers, rivets and
welding will not be considered and paid for.
(c) The measurements of rolled sections shall be
taken in length and area and the weight will be
computed as per standard steel tables, Rolling
margin and wastage if any will be to contractor's Kg 126.68
(d) Rate includes for any Rectifications and minor
works to be carried out etc. cpmplete.
37 280 Providing and fixing M.S. grills of required pattern
0.00 to wooden frames of windows etc. with M.S. flats
at required spacings and frame alround, square or
round bars with round headed bolts and nuts or by
screws. (B) ORNAMENTAL GRILL pattis, and all
other visible wooden pattis with melamine polish of
approved brand and procedure. KG 143.64
E PAVING AND FLOOR FINISH WORK
38 75.0 Providing and laying marble stone slab flooring
0 over 20mm (average)base of cement mortar 1:6 (1-
cement : 6 coarse sand) or L.M. 1:1.5(1- lime putty
: 1.5 - coarse sand) laid and jointed with gray
cement slurry including rubbing and polishing
complete. (A) Marble slab 25mm thick Sq. mt 2267.88
39 59.0 Providing and laying polished kota stone slab
0 25mm thick in risers of steps,skirtingDedo and
pillars laid on 10mm thick cement mortar 1:3 (1-
Cement : 3 coarse sand) and jointed with gray
cement slury mixed with pigment to match the
shade of slab including rubbing and polishing etc.
complete. Sq. mt 1214.30
40 120. Providing and laying Vitrified tiles 8 to 10 mm
00 thick , 36'' x 36'' in flooring treads of steps and
landing laid on a bed of 12mm thick cement mortar
1:3 (1-cement : 3-coarse sand ) finishing with flush
pointing in white cement. Sq. mt 1516.65
41 75.0 Providing and laying Vitrified tiles 8 to 10 mm
0 thick , in skrting risers of steps and dedo on 10mm
thick cement plaster 1:3 (1-cement : 3-coarse sand)
and jointed with white cement slurry Sq. mt 1103.06
42 110. Providing and laying broken china mosaic flooring
00 for terrace using 12 mm to 20 mm broken pieces of
glazed tiles to be laid over cement mortar 1:3 to
plain or slope and to be tempered to bring mortar
creme out upto surface using white cement
including rounding off junctions and extending
them upto 15 cm along the wall,clearing with water
and oxalic acid etc. as directed. Sq. mt 771.98
43 50.0 Providing and laying white or golored glazed tiles
0 of the size 300 mm x 200 mm x 8 mm / 300 mm x
450 mm x 8 mm in skirting, risers of steps and dedo
on 10 mm. thick cement plaster 1:3 (1 cement :
coarse sand) & jointed with white cement slurry.
44 910. Providing & fixing heritage cement / Athangudi
00 tiles in COMMUNITY HALL ,EVENT HALLS,
MEETING ROOMS including base preparation,
polishing & sealing Sq. mt 2250.00
45 300. Providing & fixing heritage patterned vitrified tiles
00 (Moroccan/Jaipur design) in150mm border along
with kotah stone in PASSAGES AND FOYER
AREA Sq. mt 2250.00
46 450. Providing and fixing Kota stone flooring of
00 approved green and brown shades in leather finish
(machine brushed anti-skid texture), 20–25 mm
thick,laid over 20 mm thick cement mortar bed
(1:4), including dressing of edges,jointing with
cement slurry mixed with matching pigment,
curing, and cleaning and sealing is complete.in
PASSAGES AND FOYER AREA Sq. mt 1750.00
47 377. Providing and Fixing 16 mm thick Kota stone
00 skirting of 100 mm height with C.M. 1:4 (1
Cement:4 Sand) in good line and level Rmt 180.00
48 40.0 Providing & fixing 15 mm thick kadappa stone riser
0 in the STAIRCASE including polishing Sq. mt 1250.00
49 80.0 Providing & fixing 15 mm thick Jaisalmer stone
0 steps in STAIRCASE including polishing Sq. mt 1800.00
50 110 8 mm thick Vitrified Skirting (100 mm height)
0.00 matching the flooring Rmt 350.00
51 120. Providing & laying 8 mm thick vitrified tile
00 flooring complete in male female toilet area Sq. mt 1350.00
52 240. Providing & fixing 8 mm thick vitrified tile skirting
00 100 mm height in male female toilet area Rmt 180.00
53 39.0 Providing and fixing 12 mm thick wooden flooring
AND GREEN ROOMS Sq. mt 4262.00
54 90.0 Providing and laying integral cement based water
0 proofing treatment Average 120 mm thick
including preparation of surface as required for
treatment of roof, balconies, terraces etc. and
making necessary vata at the junction of Wall and
floor wherever required as directed by Engineer In
Charge and consisting of following operation
.Applying and grouting a slurry coat of neat cement
using 2.75 kg/Sq.Mt. Of cement admixed with
proprietary water proofing compound conforming
to IS .2645 over the RCC slab including cleaning
the surface before treatment. Laying cement
concrete using broken bricks/brickbats25 mm to
100 mm size with 50% of cement mortar 1:5 (
cement , 5 coarse sand)admixed with proprietary
water proofing compound conforming to IS
over 20 mm thick layer of cement mortar of mix 1:5
After two days of proper curing applying a
second coat of cement slurry admixed with
proprietary water proofing compound confirming to
IS 2645 Finishing the surface with 20 mm thick
jointles cement mortar mix 1:4 (1 cement, 4 coarse
sand) admixed with proprietary water proofing
compound conforming to IS: 2645 and finally
finishing the surface with trowel with neat cement
slurry and making of The whole terrace so finished
shall be flooded with water for a minimum period
of two weeks for curing and for final test.all above
operations to be done in order and as directed and
specified by Engineer -In- charge Sq. mt 1890.00
55 110. Providing and laying cement concrete flooring
00 1:2:4 (1 Cement : 2 Sand : 4 graded stone
aggregates 20 mm nominal size) laid in one layer
and finished with a floating coat of neat cement (A)
50 mm thick. Sq. mt 435.00
56 110. Providing and layingbrick bat koba concrete for
00 china mosaic bedding Sq. mt 750.00
57 100. Providing and Laying of Rubber Moulded Paver
00 Block Grey/Coloured 60 mm thick, M-35 Grade of
any size ; shape (Usually Uni-Paver Blocks) using
black trap good quality aggragate of 20 mm
nominal size for footpath, parking areas, service
lanes and other areas as mentioned in the drawing /
instruction of engineer in charge. Cost includes
formworks using rubber mould,providing and
laying paver blocks as per required grading and
specification. The paver block shall be
mechanically compacted. The work of paving
blocks shall be executed in line and level by skill
mason of flooring work only. It should be laid in
such a way that the no cutting of the paver block to
be necessary. if cutting of paver block necessary
then it should be cut by machine only and carting.
The finished surface of the paver block shall have
resonably good, plain finished. Paver blocks shall
be compacted and shall be relaid if necessary.
Gravel or such type of materials shall not be
allowed for production. Laying on 5 cms thick sand
bedding Sq. mt 501.60
58 100. Providing and fixing pre-cast concrete kerb stone of
00 gray cement based concrete block 30 cm length x
30 cm heigh and 75 cms thick of M-200 grade
concrete as per approved design and including
excavation for fixing in proper line and level, filling
the joints in C: M 1:3 (1 Cement : 3 Fine sand) etc.
complete. Rmt 328.00
F PAINT AND POLISH WORK
59 180 Providing & Applying two coat of white putty of
0.00 Birla or equivalent at all levels to internal plaster
surfaces/POP surfaces of concrete, masonry work
including jambs, sills, grooves, pattas, rounding of
corners after thoroughly brushing the surfaces free
from mortar dropping and other foreign matter and
also including preparing the surface even and sand
papered smooth etc. after applying every coat of
putty. Priming coat of alkali resistant cement primer
(water or solvent based) is to be applied before at
all levels, all floors, all height, all complete as per
drawing, specifications, instruction & directions of
the Engineer-in-charge. Payment shall be done as
per drawing/laid at site of plastered area. Approved
Brands : J.K. White, Birla, Asian. Sq. mt 40.19
60 100. Painting two coats (excluding priming coat) on new
00 steel and other metal surface with enamel paint,
brushing, interior to give an even shade including
cleaning the surface an even shade including
cleaning the surface of all dirt, dust and other
foreign matter. Sq. mt 86.94
61 100. Painting one coat extra on new steel and other metal
00 surface with enamel paint, brushing, interior to give
an even shade including cleaning the surface an
even shade including cleaning the surface of all dirt,
dust and other foreign matter. Sq. mt 50.40
62 150 Painting two coats (excluding priming coat) on new
0.00 wood and other wood base surface with enamel
paint, brushing, interior to give an even shade
including cleaning the surface an even shade
including cleaning the surface of all dirt, dust and
other foreign matter. Sq. mt 104.12
63 180 Wall painting (Two coats) with plastic emulsion
0.00 paint of approved brand and manufacture on
undecorated wall surface to give an even shade
including thoroughly brushing the surface free from
mortar droppings and other foreign matter and sand
papered smooth. Sq. mt 140.00
64 180 Finishing wall with weather proof exterior emulsion
0.00 paint on wall surface (two coats) to give an required
shape even shade after thoroughly brushing the
surface to remove all dirt, and remains of loose
powdered materials.etc complete Sq. mt 113.40
65 15.0 Providing and fixing exterior grade teak wood
0 door/window frames made from well-seasoned
timber having a moisture content of 12–15%,
including machining, rebates, mortise-tenon joints,
preservative treatment to concealed surfaces,
stainless steel holdfasts, fixing in masonry, and
finishing smooth complete as per drawings and 200000.0
specifications. Cmt. 0
66 10.0 Providing and fixing teak wood external door
0 shutters of approved thickness and design
including styles, rails, panels or glazing provision,
waterproof adhesive joints, machining, sanding,
preparation for hardware and application of
approved exterior wood finish complete as per 190000.0
drawings and specifications. Cmt. 0
67 6.50 Providing and fixing carved teak wood pillar /
column including base, shaft and capital as per
architectural drawings, complete with carving work,
machining, stainless steel anchoring arrangement,
preservative treatment, sanding and exterior 211860.0
protective coating. Cmt. 0
68 3.00 Providing and fixing decorative wooden brackets
/ fascia made from seasoned hardwood including
shaping, joinery, anchoring to structural support,
preservative treatment and exterior finish complete
as per architectural details. Cmt. 0
69 50.0 Wooden handrail as per design for the staircase
0 Made out of hard wood (teak,sal)with pu polish Rmt. 6000.00
H CEILING AND GLASS WORK
70 195. Providing and fixing sheet glass, selected quality
00 (Type-C) bedded in putty and fixed with wooden
beading, including the cost of wooden beadings of
first-class teakwood and necessary cutting of glass.
(2) 6 mm thick. Sq. mt 1176.10
71 21.0 Providing and fixing glazed louvered glass
0 windows and ventilators with teak wood frame
10cm. x 7cm. size including 3 coats of oil painting
to wood work etc.complete. Sq. mt 4102.54
72 550. Providing and fixing PVC printed false ceiling
00 with flush type with alluminium frame, frame work
is done with three different sections of G.I. sheet of
24 gauge thickness named as C, U and L. The C
section is fixed with hangers at an equal distance of
36” each and then U section is fixed perpendicular
on C section with steel screws at and equal distance
of 16” each. The complete frame work is supported
by G.I. L angle/6 mm rod hangers from the roof and
L sections is fixed all around the wall as shown in
the diagram. 5mm PVC sheet strips of size 2 wide
are fixd with counter sunk steel screws on the U
section. Further 3mm PVC sheet is stuck to these
PVC strips with solvent cement such that joining
lines are perfectly matched. P.U. putty is filled,
dried and leveled and requisite coats of primer and
paint is done on the ceiling for getting fine surface
finish etc. complete as per direction of Engineering
and charge manufacturer’s specification and
drawing. Sq. mt 902.00
73 550. Providing and fixing wooden planks ceiling with
00 tounged and grooved jointing and wood screws
(frame work and cover fillings to be measured and
laid for separately) (A) Indian Teak wood (iii)
25mm thick Sq. mt 1792.68
74 15.0 Providing and fixingM.S. Fan clamps type 1 to
0 16mm dia M.S. bar bent to shape with hooked ends
to R.C.C. slabs curing, laying including painting the
exposed portion of loops, all as per standard design
complete. Eac h 130.98 11011 11.21 Extra over rate
of item 20 for providing and fixing M.S. fan clamps
type-II as per standard design in R.C.C. beams
during laying towards additional height of the
clamp due to beam rib. Cm Height 1.49
11.23 Providing and fixing M.S. round holding
down or anchor bolts with nuts and washer plates
complete. Each 124.74
75 550. Providing and fixing wooden false ceiling including
00 framework, ceiling boards, suspension system,
finishing and all complete as per drawings and
directions of Engineer-in-Charge.Framework to be
fixed true to line, level and plumb. Grid spacing
600x600 mm. Boards fixed with screws. Provide
cut-outs for services. Framework: Seasoned
wooden battens 50x25 mm or GI sections. Boards:
12 mm BWR/BWP plywood. Suspension: MS rods
6–8 mm dia. Finish: Veneer/laminate/ PU polish.
Fasteners: SS/GI screws. Sq. mt 3140.00
I GFRP AND ROOFING WORK
76 68.0 Providing and fixing Glass Fiber Reinforced
0 Polymer (GFRP) elements of approved design,
shape, size, and pattern as per drawings and
instructions of the Engineer-in-Charge.The GFRP
shall be manufactured using isophthalic
polyester/vinyl ester resin reinforced with E-glass
fiber, produced through hand lay-up or spray-up
process in approved moulds.The minimum
thickness of GFRP elements shall be 5 mm, unless
otherwise specified.The outer surface shall have a
UV-resistant gel coat finish, smooth or textured as
per the approved sample. The material shall be
resistant to weathering, moisture, and temperature
variations.The GFRP panels shall be fixed over MS
structural framework (minimum 40x40x3 mm)
anchored to the base structure using approved
anchor fasteners. Panels shall be fixed using SS
screws, rivets, or adhesive as required.All joints
shall be properly sealed using weatherproof silicone
sealant.The rate shall include:Cost of materials,
labour, moulds Transportation, loading/unloading
Scaffolding and installation All leads and lifts
Finishing and cleaning. Complete work shall be
executed as per approved drawings and sample, to
the satisfaction of the Engineer-in-
Charge.Submittals Required Shop drawings
Material test certificate Sample panel (mock-up) Sq. mt 88275.00
77 550. Stone-coated roof tiles fixing over an aluminium
00 sheet, including accessories Sq. mt 3500.00
78 110 Providing & fixing aluminium roofing sheet
0.00 mm thick with 50 mm thick rock wool insulation,
including fasteners, sealants, overlaps, flashing,
complete Sq. mt 2600.00
79 121 Providing, Fabricating, Transporting and Erecting
00.00 in position at all levels as per drawing welded /
bolted / riveted steel structures with field bolting /
riveting / welding / drilling whebever necessary and
finally full welde after completting erecting work,
applying one coat of rust remover one coat of anti -
corrosive red oxide paint or yellow zinc chromate
for MS truss including erection Kg 120.00
80 385 Providing, Fabricating, Transporting and Erecting
0.00 in position at all levels as per drawing welded /
bolted / riveted steel structures with field bolting /
riveting / welding / drilling whebever necessary and
finally full welde after completting erecting work,
applying one coat of rust remover one coat of anti -
corrosive red oxide paint or yellow zinc chromate
for Purlins Kg 110.00
81 100. Providing and fixing GI/Aluminium gutters having
00 section 400 mm wide and 150 mm deep with
mm thick sheet Rmt 800.00
82 28.0 P&F PVC Downpipes of 100 mm dia 4 Kgf/sqcm
83 120. Flashing & ridge caps
84 480. Providing, laying and fixing in position galvalume
00 pre painted and pre coated (PPGA) trapezoidal
profile sheets (size, shape and pitch of corrugation
as approved by PMC / ARCHITECT / ENGINEER)
with special male / female side laps and anti
siphoning feature at male and to prevent leakage
made from high tensile strength - 345mpa / 500mpa
GALVALUME steel and AZ-150gsm Zincalume
coating to total on both side as per ASTM
(55% aluminium + 43.5% zinc and 1.5% silicon)
having sheet 0.55mm TCT at top and base metal
thickness 0.48/0.5mm including colour coating of
20 micron finish coat over 5 micron primer coat on
exposed side and back coat of 5 microns over a
primer coat of 5 microns and having protective gard
film of 25 micrones to avoid stretches while
handling the sheet and upto erection process for
roofing and side
clading, approved make and approved shade, for
roofing at all levels and heights including cutting
sheets and drilling the holes with side laps as
required and end laps 150mm to 200mm including
fixing by self tapping and self drilling 8 mm dia x
55mm long SDST screw of 'BUIDEX' or
corroshield make as per AS - 3566 class-3 with
EPDM seal, washer of 25mm dia 3mm thick
bitumen washer with
6mm central hole to form water proof joint etc. and
using templates as suggested by manufacturer to
ensure proper side laps for any pitch in horizontal
and verticle or curved surface, etc. complete and as
directed and spaecified by PMC / ARCHITECT /
ENGINEER. for roofing 0.50 mm thick Sq. mt 650.00
85 56.0 Do as per above item but for ridge about 500 mm
0 wide having 0.50 mm thickness Rmt 775.00
J PLUMBING AND SANITARY WORK
(Supply,Installation,Testing&Commisioning)of C
PVC (SDR-11) water supply, comprising of
necessary fittings like ,elbows ,tees, unions,
reducers, coupling , pipe nipples etc.comp.
confirming to relevant ASTM D standards
necessary brass threaded male / female adaptors or
elbows necessary clamps or hangers of approved
make and made out heavy FRP channel, Zinc
Coated L clamp, G.I U clamp covered with EPDM
or Silicon rubber and Anchor fasteners etc.comp
Zari cutting with el.grinder& finishing the same in
wall or floor for concealing the pipe line jointing
materials like solvent cement along with primer
base of solvent of pipe and fitting supplier's
a 25.0 20 mm dia. (NB) pipe line
b 55.0 25 mm dia. (NB) pipe line
c 75.0 40 mm dia. (NB) pipe line
d 15.0 50 mm dia. (NB) pipe line
87 Providing and Fixing PVC SWR Pipes and Fittings,
solvent fix 6kg/cm2, confirming to IS4985 and
IS7834 including all fixtures such as Couplers,
Elbows, Tees, etc...
a 24.0 40 mm dia. (OD) pipe line
b 191. 110 mm dia. (OD) pipe line
c 15.0 160 mm dia. (OD) pipe line
d 10.0 200 mm dia. (OD) pipe line
88 SITC of C PVC/U PVC Ball Valve for water
supply pipe line. comprising of Jointing materials
like solvent cement along with primer base of
solvent of same company make only
a 2.00 C PVC ball valve of Heavy duty confirming to
relevant ASTM D standards 40 mm dia. (NB) pipe
line Nos. 1000.00
89 Providing and Fixing Eurpean Type W.C. of
following make and model
a 16.0 Providing and Fixing Concealed flush tank
0 comprising of Nos. 6300.00
Providing and Fixing Concealed flush tank with
upper plate (Jaquar cat.No.JCS-JCS-WHT-2400
and Plate Cat.no.JCP-CHR-352415)
making necessary Brick masonry wall (approx.
1000x600*150mm thick) with single coat of plaster
to concealed the flush tank with chair bracket as per
architectural design
b 16.0 Providing and Fixing ewe wall mounting suite with
0 proper line, level (Jaquar cat.No.CNS-WHT-
961SPP with seat cover) Nos. 11000.00
c 16.0 Providing and fixing Health Faucet with one metre
0 long easy flex tube in chrome finish and wall
flange(cat.No - ALD-563) Nos. 1500.00
d 16.0 Providing and fixing toilet paper holder:C.P.
0 brass( Cat . NO- CAN-1153S) Nos. 1500.00
90 Providing and Fixing Washbasin of following make
a 13.0 Providing and Fixing wash basin above counter
0 type comprising of. Nos. 12500.00
Providing and Fixing waste coupling and Bottle
trap for wash basin (Jaquar cat.No.FLS-WHT-
Making Hole for waste coupling- Pillar Cock or
basin mixer on platform
Providing and Fixing waste coupling
(Jaquarcat.No.ALD 705 L 130)
Providing and Fixing bottle trap
(Jaquarcat.No.ALD 769 L 300/190)
b 13.0 Providing and Fixing Pillar Cock comprising of.
Providing and Fixing Pillar Cock (Jaquar
cat.No.FLR-5011N)
Providing & Fixing necessary 450mm long Braided
hose with nut and washer of Jaquar make ALD-
c 13.0 Providing and fixing liquid soap container (Cat No-
d 13.0 Providing and fixing PTMT towel ring. (Cat No -
0 CAN 1121BN) Nos. 1200.00
Providing and fixing mirror of superior glass (of
approved quality) and of required shape and size
with plastic moulded frame of approved make and
shade with 6 mm thick hard board backing :
e 13.0 Rectangular shape (Cat No - AKP-35795)
91 Providing and Fixing Urinal of following make and
a 12.0 Providing and Fixing Sensor type urinal flushing
0 system comprising of. Nos. 21300.00
Providing and fixing white vitreous china flat back
or wall corner type lipped front urinal basin (Cat
No- URS-WHT-13257)
Providing Sensor type Urinal flushing system of
jaquar make cat. No SNR-STL-51087
Fixing sensor type flushing system at proper
location with necessary concealed box fittings etc.
b 12.0 Providing and fixing Bottle Trap (Cat No- ALD
c 12.0 Providing and Fixing waste coupling
0 (Jaquarcat.No.ALD 705 L 130) Nos. 825.00
92 Providing and Fixing S.S. Kitchen Sink of
following make and model
a 2.00 Providing and Fixing Stainless steel sink made out
of 1mm thick Nirali make Popular Range, Large
having Bowl size 460 x 460 x 230 mm, comprising
of. Nos. 8000.00
Providing & Fixing brackets
b 2.00 Providing and Fixing wall mounted sink cock with
regular swinging spout comprising of. Nos. 2600.00
Providing and Fixing wall mounted sink cock with
regular swinging spout (Jaquar cat.No.FLR-5347N)
Providing & Fixing necessary heavy C P flange &
extension nipple heavy of Viking or Eq.make with
c 2.00 Providing and Fixing Angle Cock comprising of. Nos. 1500.00
Providing and Fixing Angle Cock ( Jaquar
cat.No.FLR-5053N)
Providing & Fixing necessary heavy C P flange &
extension nipple heavy of Viking or Eq.makewith
d 2.00 Providing and fixing Bottle Trap (Cat No- ALD
93 42.0 110x110mm dia.(OD) Deep Seal P trap having
0 water Seal not less than 50mm Nos. 680.00
94 Providing and Fixing Pumps & Pressure System
a 1.00 Submersible Twin Pump System using Grundfos
Make Openwell Submersible Pumps,
2 Pumpsets (1W + 1S),Each Motor Rating : 1.5kW
(2 HP), Three PhaseSystem Rating : 3.0kW (4 HP),
Three PhaseEach Pump : Flow 122 LPM @ 39 Mtr.
Delivery HeadSystem : Flow 244 LPM @ 39 Mtr.
Scope of Supply:Horizontal Submersible Pumpsets
- 2 Nos., Multi Pump Controller - 1 Nos., Float /
Magnetic Sensor - 2 Nos.incl. of Material Handling
& Commissioning Charges
Controller Features:One Working One Assist
Operation With Auto Cascading (Alternating
Logic) of Pumps, Over Load / Dry Run Protection,
Digital Display, On - Off Timer & Hooter
Connection AU 0
b 1.00 Pressure Booster System Grundfos Make HYPN
Booster System - Single VFD
2 Pump + Motor sets (1W + 1S),
Each Motor Rating : 1.5 kW, Three Phase, IE
System Rating : 3.0 kW, Three Phase, IE
Each Pump : Flow 10 M3/hr @ 30 Mtr. Delivery
System : Flow 20 M3/hr @ 30 Mtr. Delivery Head
Pump M.O.C.: Base - CI, Impeller & Chamber - SS
Scope of Supply:
Pump with Motor - 2 Nos, Pressure Transmitter -
Nos, Non Return Valve - 2 Nos, Isolating Valve -
Nos, Pressure Gauge - 1 Nos, Base Frame (MOC :
MS, CED Coated) - 1 Nos, Suction and Discharge
Manifolds (MOC : MS, CED Coated) - 1 Nos,
Single VFD Pump Controller - 1 Nos, 100 Ltr.
Pressure Tank – 1 Nos., Dry Runing Protection
Sensor for UG tank - 1 Nos. AU 520000.00
95 6.00 Providing and fixing in position cowl vent to pipes.
(B) 75 mm diameter. Nos. 450.00
96 6.00 Providing and fixing in position cowl vent to pipes.
(C) 110 mm diameter. Nos. 600.00
97 10.0 Providing and fixing 12 mm dia C.P. bib cock of
0 approved make like jaquar or Essess or any other
type and make specified by the Architect. All pillar
cocks, stop cock, angle cock etc to be Jaquar or
EssEss make with quarter turn disc ceramic
cartridge and chrome finish. Nos. 1500.00
98 4.00 Providing and fixign S.W. gully trap with C.I.
grating brick masonary chamber and water tight
C.I. cover with frame of 300 mm x 300 mm size
(inside) with standard weight (i) Square mouth
traps. (A) 100 mm x 100 mm size P- Type. Nos. 1997.22
99 4.00 Constructing chamber of following size including
excavation, refilling, BBCC (1:5:10) for
foundation, Cement concrete channel(1:2:4)
finished with 15 mm thick cement plaster inside in
cement mortar 1:3, finished with cement slurry,
brick masonary in C.M. 1:5 and excluding the cost
of chamber seat cover etc. complete. (ii) for size
600 x 750 mm inside clear for depth
0.00 to 900 mm for pipe dia<= 200 mm diameter. Nos. 7109.35
100 500 Construction of under ground tank with 23 cm
00.00 thick Masnory wall in c.m. 1:6 incl. Excavation,
necessary 23 cm P.C.C. in 1:4:8 for foundation and
providing R.C.C. 1:2:4 for top slab ( 150 mm thick
& bottom slab (120 mm. thick). Also having
mm. thick R.C.C.(1:2:4) paradi on internal face of
periphery walls. Rate includes all necessary
formwork, T.M.T. steel reinforcement as per given
design, vibrating,curing, & mixing of approved
water proofing material 1 Kg. of chemical with
every 50 Kg.bag of cement ,inside plaster in C.M.
1:3 and vatta in C.M.1:1 inside the tank. Providing
and fixing F.R.C. frame & cover of size 600 x
mm , F.R.P. steps etc. comp as directed. This
includes making Two tanks of various capacities. Litre 30.00
101 250 Construction of overhead tank with R.C.C. 1:2:4
00.00 pardi and top slab Rate includes all necessary
formwork, T.M.T. steel reinforcement as per given
design, vibrating,curing, & mixing of approved
water proofing material 1 Kg. of chemical with
every 50 Kg.bag of cement ,inside plaster in C.M.
1:3 and vatta in C.M.1:1 inside the tank . Providing
and fixing F.R.C. frame & cover of size 600 x
F.R.P. steps etc. comp as directed. Litre 20.00
PART -C (ELECTRICAL ITEMS)
CHAPTER - I WIRING
SECTION - 1-2 Point wiring in Copper (MODULAR)
1 Point wiring for secondary light point with 2-1.5 sq.mm
&earthwire of 1.5 sq.mm (green) both are of ISI marked
KV grade FRLS PVC insulated multistrand copper wires, in
following type of pipe to be erected concealed in / flushed on
wall/ceiling, complete with earth continuity and necessary
connection with primary light with accessories erected on
Metal / PVC box covered with 3 mm thick PC(Polycarbonet) /
Acrylic sheet for open / concealed wiring. with necessary
Lamp holder / ceiling rose / H.D.Connector as directed.
Note:- Maximum up to 6 mtrs length, excess will be considered
as Mains for Secondary Point.
163 (a) with medium class Rigid PVC pipe and accessories Pt. 131
2 Point wiring for Light / Bell with 2-1.5 sq.mm &earthwire of
1.5 sq.mm (Green) both are of ISI marked 1.1 KV grade FRLS
PVC insulated multistrand copper wires, in following type of
pipe to be erected concealed in/ on surface on wall/ceiling
complete with 6A Modular type switch / bell push &
accessories and earth continuity of following type, erected on
PVC / Metallic box, single mounting base frame covered with
textured/metallic front plate modules erected on / in wall /
ceiling as per pipe erected, with necessary Lamp holder/ceiling
rose / H.D.Connector as directed. 0
(a) with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete 0
162 Cat. III Pt. 372
3 Point wiring for FAN with 2-1.5 sq.mm &earthwire of
sq.mm (Green) both are of .ISI marked 1.1 KV Grade FRLS
PVC insulated multistrand copper wires, in following type of
pipe to be erected concealed in / flushed on wall/ceiling
complete with 6A Modular type switch and hum free EME four
or more step type electronic fan regulator with separately
mounted and accessories with earth continuity of following
type erected on PVC / Metallic box, single mounting base
frame covered with textured/metallic front plate modules
erected on / in wall / ceiling as per pipe erected. with necessary
ceiling rose / H.D.Connector as directed. 0
(a) with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete 0
60 Cat. III Pt. 632
4 Point wiring for Individual Plug with &earthwire of 1.5 sq.mm
(Green) both are of ISI marked 1.1 KV grade FRLS PVC
insulated multistrand copper wires, in following type of to be
erected concealed in / on surface of wall / ceiling complete with
Modular type switch & 5 pin Plug erected on PVC / Metallic
box covered with appropriate front plate modules erected on /
in wall / ceiling as per pipe erected with following type of
[I] For 6A Plug and 6 a switch with 2-1.5 sq.mm Cu. Wire
from nearby switchboard/mcbdb board 0
(a) with medium class Rigid PVC pipe and accessories erected
flushed on wall/ceiling complete 0
70 Cat. III Pt. 471
5 Point wiring for Looped Plug with 6A Modular type switch &
pin socket erected on PVC / Metallic box, single mounting base
frame covered with textured / metallic front plate modules
erected on / in wall / ceiling with following type accessories 0
79 Cat. III Pt. 255
6 Providing following type of Modular Type Accessories
mounted with pvc / metallic box, single mounting base frame
covered with textured / metallic front plate , modules erected
with necessary connection. As desired by Engineer In charge 0
(9) 16 Amp. SP one way switch 0
43 Cat.III Ea. 179
(10) 6/16Amp. Universal socket 0
43 Cat.III Ea. 198
Section :- 1- 3 / Conduits & Pipes 0
7 Providing and erecting ISI mark Medium class RIGID PVC
PIPES of following size complete to be erected on/in wall or
ceiling erected with necessary PVC fittings & Junction boxes
fixed with adhesive solution & Clamps with following dia of
pipes, in approved manner as directed 0
25 (a) 20 mm Mtr. 33
8 Providing & erecting PVC Corrugated Flexible Conduit with
required nos. of coupling, PVC bushes, Check-nuts etc.
complete of following sizes. 0
Section 1-4 Mains & Wires 0
9 Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be
erected concealed in /flushed on wall/ceiling, with 1.5 sq. mm
copper conductor FRLS PVC insulated stranded wire of green
colour for earth continuity of following size 0
(a) with medium class Rigid PVC pipe and accessories 0
1500 (b) 2 wire 2.5 sq. mm (From LDB to SB and SB) Mtr. 82
10 Mains with 1.1 KV grade FRLS PVC insulated ISI marked
stranded Copper conductor wire in following type of pipe to be
erected in / on wall / ceiling with 2.5 sq. mm copper conductor
FRLS PVC insulated stranded wire of green colour for earth
continuity of following size 0
. (a) with medium class Rigid PVC pipe and accessories 0
1000 (a) 2 wire 4 sqmm Mtr. 111
11 Providing & Erecting approved make following size of TV Co-
axial flexible cable comprising inner conductor of solid bare
copper insulated with Foam PE & Secondary conductor made
of poly - Aluminium film bonded Al. Braids @ suitable
coverage overall sheathed with black PVC insulation. 0
50 (c) RG - 6 CCS Mtr. 21
12 Supplying & erecting approved make Telephone Cable
electrolytic copper conductor PE insulation twisted in two
pairs, & wrapped with FRLS PVC tape & sheathed with
FRLS PVC or HFFR outer Jacket suitable for telephone wiring
& confirming to C-DOT erected in existing pipe. of following
size of conductors &nos.of pairs. With necessary connections. 0
[A] Conductor Size 0.5 mm 0
(a) Unarmoured 0
75 (2) Two Pairs Mtr. 20
LED LUMINARIES 0
Indoor LED Fittings 0
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power
Factor more than 0.95, THD <15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/ aluminium die cast
powder coated and high U.V. & corrosion resistance with
diffuser with company mark/name 160V to 270V, Power
Factor more than 0.95, THD <15%,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt ,LED
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
12 (i) 5-10 Watts, Surge-2 KV, IP-20, conventional 1 to 2 feet
28 Cat-lll Ea 164
(iii) 18-20 Watts, Surge - 2KV,IP-20, conventional 4 feet
42 Cat-lll Ea 293
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast
powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD <15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
Supplying and erecting LED indoor fittings with LEDs of
wattage 0.2 Watt to 0.5 Watt assembled on single MCPCB,
with housing used as a heat sink shall be made of thick sheet
Steel conforming to IS: 513/CRCA/aluminium pressure die cast
powder coated and high U.V. & corrosion resistance with
diffuser housed in aluminium casted body with company
160V to 270V,Power Factor more than 0.95, THD <15 %,
CCT 3000 K to 6500K,
Luminaire efficacy> 85 lumens/watt
LED driver efficiency > 85 %
( fitting required LM-79 & LM-80 Certificates)(NOTE: Below
description have shown ranges of Wattage capacity of LED
fittings.The Engineer incharge may select any wattage capacity
between the ranges shown.)
(A) Square/ Circular shaped Surface/Recessed Mount
Downlight with provision for spring loaded mounting clips
(i) 5-9 watts,Surge-2 KV
82 Cat-lll Ea 218
(ii) 11-15 watts, Surge-2 KV
14 Cat-lll Ea 423
(iii) 16-20 watts, Surge-2 KV
110 Cat-lll Ea 584
13 Supplying and erecting LED street light / Flood light fittings
with High power White LEDs wattage of 3 Watt and above
assembled on single MCPCB, efficiency more than 130 lm/w
and corrosion free High pressure die cast aluminum housing
with smooth finish powder coated and heat sink extruded
aluminium with diffuser and Polycarbonate optics/ lenses, with
toughened glass with company mark/name engraved or
embossed 160 to 270 V,Power Factor more than 0.95, THD <
10 %, CCT 3000 K to 5700K,Uniformity ratio >0.45,
Luminaire efficacy> 100 lumens/watt . LED driver efficiency >
85 %.( fittings required LM-79 & LM-80 certificates)(NOTE:
Below description have shown ranges of Wattage capacity of
LED fittings.The Engineer incharge may select any wattage
capacity between the ranges shown.)
(C) Post Top Lantern LED fitting comprises of finish cast
aluminum spigot and spun aluminum canopy fixed with opal
polycarbonate, pipe arrangement for vertical mounting driver
and accessories wired upto terminal block.IP
25 Cat-lll Ea 4052
(G) Step Light having Aluminium die cast and ABS Plastic
(i) 5 watts, Direct/Indirect luminaire
6-1 STREET LIGHTPOLES
Indoor LED Fittings
14 Supplying & erecting Galvanized M.S pipe post “B” class
mm O.D 4 mtr. Long duly painted with two coats of
aluminium paint complete with metallic base plate of 300 mm x
300 mm x 4mm thick for using as a compound light pole with
approx. weight 32 Kg.
15 Supplying &erecting approved make SMC press moulded
composite FRP. loop-in, loop-out approx. 2mm thick box
complete with Bakelite connector strip 5way(3P+N+E),DIN
rail for mounting mob & hinged doors as per requirement
having locking arrangements with mounting clamp with nuts,
bolts & washers suitable for erection on pole with cable
clamps& earth bolt of following size of box.
25 (B) 250mm x 200mm x 100mm [deep] Ea. 510
16 Providing 1:2:4 cement concrete foundation & 70 % PCC from
bottom including excavation for the pole of size 45 x 45 x
cm. Deep in below ground level with plinth of 45 cm x 45 cm
(or 45 cm dia x 45 cm) high upper ground level with necessary
curing and finishing in approved manner.
( for 4 & 6 mtr pole)
SWITCHGEARS & DISTRIBUTION BOARDS 0
Section 3-4 MOULDED CASE CIRCUIT BREAKERS 0
14 Providing and erecting Approved make Four pole moulded case
circuit breaker having breaking capacity ICU of 25 KA. at
V,having normal current rating up to 25 A to 100A. with Fixed
thermal & magnetic release suitable to work on A.C. supply
c/s. with all internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S. housing. 0
6 ICS=100% of ICU only Cat III Ea. 6112
17 Providing and erecting Approved make Four pole moulded
case circuit breaker having breaking capacity ICU of 35 KA. at
415 V. having Normal current rating 200A.with variable
Thermal & magnetic release suitable to work on A.C.supply
c/s. with all internal connections, spreader tinned copper &
complete erected in existing 16 G.M.S.housing 0
2 ICS=100% of ICU only Cat III Ea. 16061
Section 3-8 / PANEL MOUNTING BUSBARS 0
18 Supplying and erecting triple pole & neutral 440V / 500V panel
mounting Copper Busbars with four equal Nos. of electrolyte
bus having current density not more than 1.6 Amp. / sq.mm
(Rated current / cross section area) duly wrapped with colour
insulating tape for phase sequence of following current carrying
capacity, erected with necessary bus bar supports /insulators,
main cable socket to each bar, erected in existing cubical panel
with necessary connections. 0
14 (B) Suitable for 200 Amp. capacity Rn.Mtr 3171
12 (C) Suitable for 300 Amp. capacity Rn.Mtr 4861
SECTION 3-10 / MINIATURE CIRCUIT BREAKERS 0
19 providing and erecting Miniature circuit breaker single pole 6A
to 25A suitable to operate on 240 V A.C. system and having
breaking capacity 10 KA to be erected in existing box.
confirming to IS 8828/1996 with ISI Mark 0
110 Cat.III Ea. 111
20 Providing & erecting 240 V MCB double pole switch for motor
& inductive load (C Curve) having 10 KA breaking capacity
& confirms to IS : 8828 in existing box having following
21 Providing & erecting 415 V MCB Four Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity 0
8 Cat III Ea. 662
12 Cat iii Ea. 730
22 Providing & erecting 415 V MCB three Pole for Motor &
Inductive Load (C Curve) having 10KA breaking capacity &
confirms to IS :8828 in existing box having following capacity 0
(a) 6 to 32 Amp. 0
23 Supplying & erecting 20 Amp 10 KA ‘C Curve’ single
pole MCB with 20 Amp. Plug socket, company fabricated
powder coated sheet steel enclosure erected as directed with
[A] Metal Clad Socket with metal clad top 0
1 Cat.III Ea. 582
SECTION 3-11 MCB DISTRIBUTION BOARDS 0
24 5 Half / One Module Blanking Plate of Standard Size. Ea. 35
25 Supplying & erecting approved make RCCB + MCB (Electro
magnetic type only) working on residual current device having
10 KA short circuit breaking capacity and 30 mAmp.
Sensitivity & 30 mili sec. tripping time conforming to IS
test knob facility trip free mechanism operating for rated
leakage at nominal ten volt, complete erected including all
materials lugs screws etc. completed.
[e] 32A to 40 A, 4 Pole Three Phase
2 Cat. II Ea. 2145
[f] 63A, 4 pole Three Phase
6 Cat. II Ea. 2806
SECTION 3-14 EARTHING 0
26 Providing and erecting required size HOT deep Galvanised iron
strip for earthing of H.T. , OCB/ ACB/ Transformer LT panel
20 board, Motors etc. using proper clamp. (25x3MM) Kg. 77
27 Providing and erecting Annealed bare Copper wire 8 to
28 Supplying & erecting in earthpit of minimum bore dia. 225mm
size ASH or approved make Safe Earthing Electrode
consisting Pipe-in-Pipe Technology as per IS 3043-1987
made of corrosion free G.I.Pipes having Outer pipe dia of
mm having 80-200 Micron galvanising, Inner pipe dia of
mm having 200-250 Micron galvanising, connection terminal
dia of 14 mm with constant ohmic value surrounded by
highly conductive compound with high charge dissipation
suitable for following type of applications. 0
[C] For Electrical Installation covering Transformer Neutrals,
Lightning arrester Earthing, A.C.Plant& Sensitive
Computer System(like Automation, SCADA)i.e.
independent Earthing located in other than normal soil i.e.
Soft Rock, Marshy Soil etc..
-Length of Pipe : 3 Mtrs.
8 -Back filling Compound :2 nos Bags of 25 Kg. Ea. 10489
SECTION 3-16 CUPBOARDS. 0
29 Providing & erecting weather proof, dust & vermin proof, floor
mounted front operated indoor type cubical panel board
necessary IP-42 and above protection as per approval from
engineer incharge made from 14 SWG thick CRC M.S. sheet
for outer body & doors, 16 SWG thick CRC M.S.sheet for
internal partitions with necessary accesories , supporting
angles/ flats channel including cutting, bending, drilling,
welding, riveting with internal partitions & cable alley as per
requirements & instruction of engineer-in-charge with erection
supplied switch gears, BUSBARS, suitable size of inter
connecting PVC copper wire / copper-aluminium strips, rubber
grommets, rib, bakelite control fuses/MCB for measuring
instruments, earth bus & earth bolts, foundation flange - bolts-
base Plates, sufficient nos. of hinged doors, handles with
locking arrangement and rubber gasket,heavy duty end terminal
connection,danger notice board,necessaryventilation,earthing
strip complete. The Panel shall be painted with epoxy powder
(The rates excludes the cost of switchgears, bus bars, inter
connecting mains & Copper Aluminiumstrips, meters, Fuses
etc. The dimension shall be measured excluding base beams)
The panel shall be supplied with following approved
manufacturers with following size.
(A) locally fabricated panel board 0
45 (i) with 350 mm depth Sq.Mtr 10365
SECTION 4-3 / ARMOURED ALUMINIUM CABLES 0
30 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Aluminium conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe of
following size of cables (VERIFY THE ACTUAL LENGTH
6 (A) 3 1/2 core 25 Sq. mm ( 16 Sq. mm 1/2 core) Mtr. 182
SECTION 4-4 / ARMOURED COPPER CABLES
31 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor for 1.1 KV. to be laid on
wall with necessary clamps or in existing trench / pipe at road
crossing or floor of following size of cable.
60 (A) 4 core 2.5 Sq. mm Mtr. 269
50 (B) 4 core 6 Sq. mm Mtr. 505
32 Providing and erecting XLPE(IS:7098)(I)-88 ISI armoured
cable multistrand Copper conductor for 1.1 KV. to be laid
on wall with necessary clamps or in existing trench / pipe at
road crossing or floor of following size of cables.
160 (A) 4 core 10 Sq. mm Mtr. 269
SECTION 4-5 MISCELLANEOUS.
33 Making trench in soft soil of suitable width of 90 cm deep for
laying cable or locating the fault all over the run and back
300 filling the same and making the surface as normal ground. mtr 55
34 Covering of cable with second class bricks or cement tiles laid
cover the cable crosswise & also on both sides with covering of
7. 5 Cm. layer of sand above & below cable (16 bricks per
375 meter) mtr 139
SECTION 4-6 / CABLE GLANDS.
35 Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
16 (\B) 2 to 4 core 2.5 / 6 Sq. mm Ea. 38
52 (C) 2 to 4 core 10 Sq. mm Ea. 38
36 Providing and, fixing heavy duty flange type brass cable gland
with rubber ring for PVC insulated armoured cable complete
with out going tails, insulating tape etc for following size of
SECTION 4-7 CABLE LUGS.
37 Solderless crimping type Aluminium lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
38 Solder less crimping type Copper lugs conforming to IS
suitable for cable of following size evenly crimped with high
pressure tool & connected to switchgear terminals with
brass/cadmium plated nut bolts in an approved manner.
CHAPTER - V Fans and Accessories
SECTION 5-1 / CEILING FANS AND ACCESSORIES
39 Providing & erecting Approved make Ceiling Fan with double
ball bearing ISI mark with Condenser 230 volt A.C.50 Hz
1200 mm sweep complete having 3 blades aluminium body and
blade sets having ornamental design shanks , canopy erected
with earthing. [ Make shall be approved by Engineer in
60 Charge] Ea. 2289
SECTION 5-2 FAN ACCESSORIES
40 Supplying and erecting 19 / 20 mm. nominal bore Medium
Class M.S. Pipe down rod erected duly painted for fan
60 complete with proper insulation without leakage and earthing. Mtr 107
41 Supplying & erecting Fan Hook of 10 mm M.S. Round bar
60 grouted in RCC slab with Making the site as original. Ea. 43
SECTION 6-7 TIME SWITCHES
42 Supplying & erecting approved make time switch with single
pole air break contacts suitable for 230 V.15/16A.complete
with self starting motor driven clock ‘ON’ &’ OFF’ automatic
arrangement at any predetermined time during each
hours,With nickel cadmium rechargeable battery backup
3 erected as directed. Ea. 2331
43 Supplying & erecting power contactor ,AC3 duty for time
switch complete erected as per direction Cat III
3 (D) 4 pole 440V 40 Amp. Ea. 2755
LIGHTNING ARRESTER
44 SITC of Vertical Air Termination Solid aluminium with Base-
10 mm dia and 1000 mm long. Air Termination Base tested for
conditioning, Ageing Test & Lightning impulse current
withstand test: 100 kA of 10/350µs waveform in an accredited
Third party laboratory as per 6.3 & 6.4 of IEC 62561-1
protocol with MAST 34mm dia 3000 mm long- Cold
2 Galvanized Each 11000
45 SITC of Galvanized Steel Flat 25x6 mm thickness from earth
electrode directly in ground as required. Zinc coating: 500 g/m
square (Approx:70 micron coating) tested and used exclusively
for lightning protection earthing system and ring equipotential
200 bonding. Mtr 153
MARKET RATE ITEMS:-
SUB PANEL & DISTRIBUTION BOARDS
46 Supply, installing, testing and commissioning of metallic
double door type distribution board with following MCBs /
ELMCBs / RCCBs / etc. with all necessary connections,
remaining blank area shall be covered with blanking (dummy)
plates etc. complete. (All DBs shall be installed concealed in
Non-Plant Bldg.) w.r.t Technical specification
Note All MCBs & MCCBs taken in SOR
47 4-WAY VTPN DB :
Incoming : 40 A FP RCBo-30mA
Outgoing : 6 to 32 A SP MCB (12 nos) (MCB TAKEN IN
2 ABOVE SOR) Ea. 12000
4-WAY VTPN DB :
Incoming : 63 A FP RCBo-30mA
Outgoing : 6 to 32 A SP MCB (12 nos) (MCB TAKEN IN
4 ABOVE SOR) Ea. 12000
4-WAY VTPN DB :
Incoming : 63 A FP MCB
Outgoing : 6 to 32 A SP MCB (12 nos) (MCB TAKEN IN
3 ABOVE SOR) Ea. 12000
6-WAY VTPN DB :
Incoming : 63 A FP RCBo-30mA
Outgoing : 6 to 32 A SP MCB (18nos) (MCB TAKEN IN
2 ABOVE SOR) Ea. 13500
6-WAY VTPN DB :
Incoming : 80 A FP MCB
Outgoing : 6 to 32 A SP MCB (18nos) (MCB TAKEN IN
1 ABOVE SOR) Ea. 13500
8 -WAY VTPN DB :
Incoming : 100 A FP MCCB
Outgoing : 6 to 32 A SP MCB (24 nos) (MCB TAKEN IN
1 ABOVE SOR) Ea. 15000
Incoming : 160 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 100 A FP MCB (1 nos) (MCB TAKEN IN
SUB PANEL SF PANEL 1 (BANQUET HALL 1)
Incoming : 160 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 100 A FP MCB (1 nos) (MCB TAKEN IN
SUB PANEL SF PANEL2 (BANQUET HALL 2)
Incoming : 80 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 40 A FP MCB (1 nos) (MCB TAKEN IN
SUB PANEL TF PANEL1 (GYMNASIUM)
Incoming : 80 A FP MCCB
Outgoing : 40 A FP MCB (2 nos) (MCB TAKEN IN
SUB PANEL TF PANEL2 (RESTAURANT)
Incoming : 80 A FP MCCB
Outgoing : 63 A FP MCB (1 nos) (MCB TAKEN IN
Outgoing : 40 A FP MCB (2 nos) (MCB TAKEN IN
48 Supply, installation, testing and commissioning of OUTDOOR
water tight fitting wall washer suitable for wall mounting with
29 12 W LED lamp complete Ea 900
49 Supply and Installation of High Volume Low Speed Fan
(HVLS) 12 feet Dia., 5 blades complete. With Motor, Control
2 Panel, Controller, Mounting arrangements etc. Ea 192500
50 Supply and Installation of High Volume Low Speed Fan
(HVLS) 10 feet Dia., 5 blades complete. With Motor, Control
4 Panel, Controller, Mounting arrangements etc. Ea 172500
PART-D ( FIRE FIGHTING ITEMS)
A FIRE HYDRANT SYSTEM
Providing, laying, jointing, testing and
commissioning of following sizes of pipes
conforming to IS-1239 and IS:3589, with all
accessories like all fittings (standard M.S.
fitting with welded joint shall be used on the
pipes) including tees, elbows, reducers, union,
flanges, rubber gaskets, GI nuts bolts,
washer including supporting/fixing the pipe
1.00 on floor / wall /ceiling with clamps, hangers
(using anchor fastners) as per specification.
All hangers, clamps, brackets etc. shall be of
galvanized iron unless specified otherwire and
then supply of the same shall also be included
for rates under this head.. Welding of any
kind on the galvanized support / hanger shall
not be permitted. Arc Welding procedure as
For wet riser System - M.S `C' Heavy class
pipe (For Hydrant ,)
Providing & fixing of Single Fire Hydrant
Valve, Single Outlet, SS-304, 63 mm female
inst. oblique type, 80 mm NB flange Inlet.,
200 mm OD, 160 mm PCD, 4 holes of
1.1 4 mm, complete with C.I wheel, PVC Blank Nos.
Cap and G.I Chain, Bearing IS:5290 mark,
Painted red. Including fixing with anchor
fastner and flanged tapping from wet riser
complete as required.
SITC of Air Release Valve For Fire Hydrant
Riser, 25 mm Male BSP
Threaded, GM, Nitrile Rubber Ball And
Sheet, Minimum 1,556.00
Operating Pressure 2 Kg/Cm2 with all
Providing & fixing swinging type ISI mark,
First Aid hose reel in red colour drum with
mts long and 20 mm dia heavy duty rubber
braided water hose , terminating with SS
coupling & nozzle of 6mm outlet with shut
1.3 4 off valve confirming to IS 8090 - 1976 Nos
complete with MS socket for tap-off, drum
and brackets (including painting) for fixing on
wall with anchor fastner, bolts & nuts
conforming to IS:884-1969 complete as
Providing and Fixing of Branchpipe,
short, Stainless Steel, 63mm male inst. inlet,
Fitted with male threaded outlet,20 mm bore
1.4 4 nozzle, Nos.
bearing IS:903 mark, suitable for inter
connection to hose pipe coupling
complete as required.
Providing and fixing Hose Box lockable
cabinet, made out of MS sheet of 16 gauge
thickness having central opening and 4 mm
thick glazed glass doors (Two nos.) suitably
marked on the outside with the letters "FIRE
HOSE" including necessary locking 1,905.00
arrangement and shall be painted with one
coat of primer and two coats of synthetic
enamel paint of approved shade.(External)
Size: 750 mm x 600 mm x 250 mm.
Providing & fixing of fire brigade connection
made from SS 304 (suction collecting head)
consisting of 4 Nos. 63 mm dia instantaneous
type male couplings with built-in check
1.60 1 valves, drain valve 1 No. 150 mm dia Nos.
butterfly valve, 150 mm dia. non return valve
with flanged outlet complete with bolts, nuts
and rubber insertions as required and as per
B SPRINKLER SYSTEM
Providing, laying, jointing, testing and
commissioning of following sizes of pipes
conforming to IS-1239 and IS:3589, with all
accessories like all fittings (standard M.S.
fitting with welded joint shall be used on the
pipes) including tees, elbows, reducers, union,
flanges, rubber gaskets, GI nuts bolts,
washer including supporting/fixing the pipe
2.0 on floor / wall /ceiling with clamps, hangers
(using anchor fastners) as per specification.
All hangers, clamps, brackets etc. shall be of
galvanized iron unless specified otherwire and
then supply of the same shall also be included
for rates under this head.. Welding of any
kind on the galvanized support / hanger shall
not be permitted. Arc Welding procedure as
For Sprinkler System - M.S `C' Heavy class
Supply Installation testing &comissioning of
UL / FM approved pendent / Upright type,
2.10 256 chrome plated / Brass finished sprinkler, Inlet Nos.
15 NB, 68 deg.with heat activated, Quick
Response type, K-115, with required
Providing and fixing of UL listed and FM
approved flexible hose
drop with required accessories and false 1,455.00
ceilling clamps.
Supply, installation, testing and
commissioning of vertical sprinkler Alarm
Valve With Motor Gong with all required
accessories like in built drain valve, test valve, -
gauge cock and pressure gauges etc. Sprinkler
alarm valve shall be FM approved.
Providing and fixing of inspector test and
drain assembly PN 16 with sight glasss, ball
valve, union, nipple etc. Test drain assembly 2,250.00
shall be comlete in all respect.
Providing and fixing of flange ended Y
strainer PN 16 with SS scrin of
mesh/sq.inch. Flange drilling standard shall be -
Providing and Fixing of hand lever operated
butter fly valve, PN: 1.6, with CI body and
S.G disc and other working parts as per IS:
13095 - 1991. With required accessories like -
matching flange, packings etc. complete as
a 0 50 mm dia Nos.
b 4 80 mm dia Nos.
c 2 100 mm dia Nos.
SITC electrically operated water flow
switches (Vane type) including tamper switch
and accessories, complete with tap off socket
arrangement as required, with potential free
contact with 2 Nos. NONC suitable to be 875.00
fixed directly on line of the foll. diameter of
pipes including cabling till alarm panel and all
other accessories to finish the installation.
Providing and fixing of Glycrinfeeledburdon
type pressure guage, made from SS working
parts and SS casing, 150 mm dial and 0-21 kg
range with calibration certificate and Shall be 810.00
fitted with shut off valve and SS 304 syphon
tube and other required accessories.
SITC of 25mm dia Air Vent Valves with
2.90 3 mm dia. Ball valve and other required Nos.
accessories like nipple, socket etc.
SITC of pressure release valve with ball valve
and accessories 3,600.00
Providing and fixing of MS support with
required anchor fasteners, insert plate etc.
2.11 1000 with one coat of zinch chromate and two caot Kg
of black enemal paint. Support shall be
complete in all respect.
C PUMP HOUSE EQUIPMENTS
Supply, installation, testing and
commissioning of electrically driven high
3.00 1 pressure centrifugal fire hydrant & Sprinkler Set
pump suitable for automatic operation
consisting of the following:
Horizontal end suction / high pressure
centrifugal pump, suitable for operation on
415 volts ± 6%, 3 phase, 50 HZ A.C supply.
The installation shall be complete with
flexible coupling and coupling guard as
required. Fire pump shall have C.I. casing,
CS diffusers, bronze impeller (hard finished
and dynamically balanced) and S.S. (304)
Shaft with mechanical seal, capable for
delivering 2280 LPM at outlet head of 70 -
MWC to ensure a minimum pressure of
Kg/Sqcm at the farthest or topmost hydrant.
The installation shall be complete with
necessary pressure gauge with gun metal shut
off cock on delivery side. (The pump should
be tested for bench mark at factory and shall
be gotten approved by the Local fire
Pump shall be capable of furnishing not less
than 150% of rated capacity at a head of not
less than 65% of the rated head. The shut off -
head shall not exceed 120% of rated head.
b. Squirrel cage induction motor, TEFC type
suitable for operation on 415 volts, 3 phase
50 HZ A.C supply, for the above pump with
synchronous speed of 2900 RPM, conforming
to IP 55 protection & class F insulation. The -
motor shall conform to IS 325-1978 (up to
date) with flexible coupling and coupling
guard, complete as required.
Common base plate for (a) and (b) from
M.S. Channel for required size. -
Suitable cement concrete foundation with
cement concrete plaster (design and drawing
to be provided by the Contractor while the
foundation will be done by others) complete -
with anti-vibration arrangement of cushy foot
Supply, installation, testing and
commissioning of Diesel Engine driven fire
3.10 1 pump suitable for automatic operation Set
comprising of the following and conforming
to BS 649/IS 10002 all amended upto date.
Horizontal, End section, Back pullout
centrifugal pump, suitable for operation on
415 volts ± 6%, 3 phase, 50 HZ A.C supply.
The installation shall be complete with
flexible coupling and coupling guard as
required. Fire pump shall have C.I. casing,
CS diffusers, bronze impeller (hard
a finished and dynamically balanced) and
CS shaft with mechanical seal, capable for
delivering 2280 LPM at outlet head of
MWCminimum pressure of 3.5 Kg/Sqcm at
the farthest or topmost hydrant / sprinkler.
The installation shall be complete with
necessary pressure gauge with gun metal shut
off cock on delivery side.
Pump shall be capable of furnishing not less
than 150% of rated capacity at a head of not
less than 65% of the rated head. The shut off -
head shall not exceed 120% of rated head.
Heat exchanger cooled (secondary cooling)
diesel engine of speed 1800 RPM suitable for
the above pump with automatic starting
mechanism and other accessories including
fuel tank (fabricated from 3mm MS sheet,
painted with two coats of synthetic enamel
paint over a coat of primer) of capacity
adequate to sustain pump operation for
c hours continuous working. The tank shall be
fitted with Magnetic oil level indicator, MH
with cover, drain valve, air vent including
structural supports (painted with approved
shade), 1 Nos. x 12 volt battery, heat
exchanger with necessary piping connections
& fittings, flexible coupling, coupling guard
& exhaust pipe connection complete as
Diseal engine tank 200 ltr capacity minimum. -
Common base plate for (a) and (b) from
e M.S. channel of required size. -
Including Diesel Engine control panel with
Battery charger. -
Suitable cement concrete foundation with
plaster, (design and drawing to be provided by
g the Contractor while the foundation will be
done by others) complete with antivibration
arrangement of cushy foot mountings.
Supply, installation, testing and
commissioning of jockey pump
(pressurisation pump) comprising of the 2,01,000.00
Horizontal end suction centrifugal pump of
180 LPM with 70 Head, suitable for operation
on 415 volts ± 6%, 3 phase, 50 HZ A.C
The installation shall be complete with
Flexible coupling and coupling guard,
complete as required.
The pump casing shall be CI, shaft shall be SS
& impeller / shaft sleeve / casing wearing ring
shall be bronze. The pump shall be provided
with mechanical seal The system shall be
complete with necessary pressure gauge with -
gun metal shut off cock on delivery side. (The
pump should meet the condition and shall be
gotten approved by the Local fire Authority).
Squirrel cage induction motor TEFC type for
operation on 415 V, 3 phase 50 HZ AC
supply for the above pump with a
synchronous speed of 2900 R.P.M. with -
flexible coupling and coupling guard etc. as
Common base plate for (a) and (b) from
M.S. channel as required size. -
Suitable cement concrete foundation with
plaster, (design and drawing to be provided by
e the Contractor while the foundation will be
done by others) complete with Antivibration
arrangement of cushy foot mounting.
Providing & fixing pressure switch assembly
with isolation valve suitable for working
pressure of 10 bar. Cost shall be inclusive of
providing any short pieces, nipples, elbows
etc as required.
General specification of pressure switch
Encloser : Painted Mild Steel to IP:33 as per
IS:13947 (Part-1)
Sensing Element Phosphor Bronze Bellows 3,700.00
Switching : 1 SPDT Contact System
Switch Rating : 6A Inductive / 10A Resistive
240V AC, 0.2A Inductive
Repeatability / Accuracy : ± 2% FSR
Process Connection 1/4" BSP (F)
Cable Entry : Suitable for 6 to 14 mm dia
Supplying, installing, testing and
commissioning of C.I. Non-return valves as
3.40 per IS:5312 (Part I) 1984, swing check type
with required flanges, nuts, bolts and gaskets
etc. complete. (PN 16 Rated.)
a 2 150 mm dia Nos.
b 1 100 mm dia Nos.
Providing & fixing of flange ended rubber
expansion bellow joint of standard length as
3.50 per manufacturers specs including rubber
gaskets, flanges, nuts, bolts and washers
complete as required. (PN 16 Rated.)
a 8 150 mm dia Nos.
Supplying, installing and commissioning of
CO2 4.5 Kg Fire Extinguisher containing
99.95% Co2 Gas, fitted with discharge hose,
wall mounting bracket etc., ISI approved as 3,900.00
per IS:15683:2006 complete with Required
size of Zebra paintaing on wall and floor.
Supplying, installing and commissioning of
ABC 6 Kg Fire Extinguisher containing MAP
50, Stored Pressure Type, fitted with Pressure
Gauge, fitted with discharge hose, wall
mounting bracket etc., applicable on Class A, 1,450.00
B,C ISI approved as per IS:15683:2006
complete with Required size of Zebra
paintaing on wall and floor.
PART -E (HVAC ITEMS)
Appendix-1- (VRF AC System with Standard VRF Units )
1 Section 1: High Side Work
Supply & Installation of Outdoor condensing
units of the following capacity with R
Gas Based Model. (Bidder to offer nearest
size of Unit & suitable combinations available
with them & must consider piping derating for
Up to 40 KWr capacity Min EER 3.28 and
40 to 70 KWr capacity Min EER 3.26 and
Above 70 KWr capacity Min EER 3.02 and
First Floor : CKT 01 - 32 HP ( 16 HP + 16 HP
)- - Top Discharge
Second Floor : CKT 01 - 20 HP ( 20 HP )- -
Second Floor : CKT 02 - 12 HP - Side
Second Floor : CKT 03 - 10 HP - Side
Third Floor : CKT 01 - 10 HP - Side
Third Floor : CKT 02 - 12 HP - Side
Supply & Installation of VRF-indoor units of
1.02 the following capacity. (Bidder to offer
nearest size of Unit available with them)
Ceiling mounted 4 way Compact Cassette
Unit with condensate drain pump
Ceiling mounted 4 way Cassette Unit with
condensate drain pump.
1.03 Remote control Systems
Cordless remote controllers ( Operating
Mode:- On/Off/Fan Speed/Mode/Temp )
Ref-net joints for above VRF systems.
1.05 1 Outdoor unit branch kit Nos. 5000
2 Section 2: Low Side Work
Epoxy painted M.S. structure for supports and
For VRF system, all refrigerant piping
between indoor & outdoor units duly insulated
as per specifications. All piping inside the
room shall be properly supported with hanger
and exposed piping shall be properly
2.02 supported in GI Perforated tray. Exposed
piping insulation to be covered with 1 layer
of glass cloth and 2 layers of UV paint and
all the insulation joints must be covered
with EPDM Rubber Tape. (minimum
mm thick Class O Insulation)
2.02.01 For Folloing HP Ref Piping
2.02.01.02 50 20 HP VRF Piping CKT
2.02.01.03 100 32 HP VRF Piping CKT
Supply & Installation of Insulated uPVC drain
piping for all VRF Indoor AC units. (All the
Insulation joint must be covered with
aerotape.) ( min 9 mm thick)
Testing & Commissioning of VRF system
along with topping-up of refrigerant Gas.
2.04.01 4 10 / 12 HP VRF CKT Nos
2.04.02 1 20 HP VRF Piping CKT Nos
2.04.03 1 32 HP VRF Piping CKT Nos
2.05 Electrcial Work:-
All Cu armored power cable between
electrical panel & VRF ODU’s located on
2.05.01 Terrace. This cabling should be properly
supported in G.I Cable trays where-ever
2.05.01.01 0 06 Sq mm X 4 Core Copper Rmt
2.05.01.02 0 10 Sq mm X 4 Core Copper Rmt
2.05.01.03 0 16 Sq mm X 4 Core Copper Rmt
10 Sq mm Cu Single core wire for earthing
All control cables between indoor and
2.05.03 outdoor unit lay in PVC pipe and clamped.(for
2.05.03.01 600 1.5 Sq.mm 2 core Shielded Control Cable Rmt
1.6 mm thk G.I perforated cable trays with
2.06 necessary structural supports, anchor bolts,
etc. for the above work.
90 Deg ODU Exhaust Air Cowl with 18 G GI
& MS Frame Work & Safety Chicken Mess
Appendix-2- (LVL 0 Room Split AC )
1 Section 1: High Side Work
SITC of DX air-cooled Split AC unit
complete with Indoor / Outdoor units along
with cordless remote controller &aditional
charge of refrigerant. (R-410a / R32
Refrigerant)(Min. 3 Star & Cu Cond.)
1.01 (Without Ref Piping )
2 Section 2: Low Side Work
Supply, Fabrication and Erecting structure
steel for support. Applying two coats of zinc
chromate primer of ICI, Asain make/eq. , with
rubber gasket between support & duct / pipe
2.01 as per specifications and drawings and as
directed by the Engineer-in-Charge client
/consultant. Make : Tata / Sail / JSW as per
IS-2062 with TC. ( with 2 coats of approved
0 color epoxy paint ) Kg 0
For AC system, all refrigerant piping between
IDU & outdoor units duly insulated as per
specifications. All piping inside the room shall
be properly supported with hanger and
exposed piping shall be properly supported
with clamp.Exposed piping insulation to be
covered with 1 layer of glass cloth and
layers of UV paint and all the insulation joints
must be covered with EPDM Rubber Tape.
For 1.0 / 1.5 TR ( Min 1/4" (0.8mm thk) &
2.02.01 6 1/2" (0.8mm thk) with min 13 mm Rmt
thkIsulation) 1000
Supply & Installation of Insulated uPVC drain
piping for all Indoor AC units. (All the
Insulation joint must be covered with
2.03.01 6 For 19/25 mm dia piping Rmt
All Cu armored power cable / control cable
between IDU to ODU’s .
2.04.01 8 4 Core x 2.5 Sqmm Copper armored) Rmt
2.04.02 0 6 Core x 2.5 Sqmm Copper armored) Rmt
2.05 1 L type Wall Mounted Powder coated GI Satnd Nos 1000
Signage Sticker for each OUD with Room
Name (for Identification) 400
2.06 2 Chipping Work in Wall Rmt 150
AHMEDABAD MUNICIPAL CORPORATION
ENGINEERING DEPARTMENT- BUILDING PROJECT
CONSTRUCTION OF COMMUNITY BUILDING AT T. P. S. No. 5 (City Wall Improvement)
(Section – 7) Final Sanc., F. P. No. 26, At: Dariyapur - Kazipur, Taluka: City, District:
Ahmedabad, near dariyapurgatedariyapur ward central zone, Ahmedabad
FINANCIAL BID (Online Only)
RECAPULATION SHEET
SR.NO. DESCRIPTION AMOUNT
1 EARTH WORKS & ALLIED WORKS
2 CONCRETE & ALLIED WORK
3 STRUCTURAL STEEL & ALLIED WORKS
4 ROOFING & ALLIED WORKS
5 MASONARY AND PLASTER WORK
12 AS PER MARKET RATE
13 TOTAL ELCRTICAL WORK
14 VRF AC SYSTEM WITH STANDARD VRF UNITS AND SPLIT AC
15 A. FIRE HYDRANT SYSTEM
16 B. SPRINKLER SYSTEM
17 C.PUMP HOUSE EQUIPMENT
18 Heritage Impact Assessment (HIA)
I/We am/are willing to carry out work at ______% above / below (should be written in figures and
the estimated cost mentioned above.
Estimated cost put to tender :Rs.00000 Estimated cost put to tender :Rs.000000
Add_____% above : Rs ___________ Deduct_____% below : Rs __________
In words : Rupees
Signature of contractor Additional City Engineer (Central Zone )
Seal Ahmedabad Municipal Corporation
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
AMC_Commuity Hall Drawing-1-4.pdf
AMC_Commuity Hall Drawing-5-8.pdf
update part a.pdf
part b.pdf
part c.pdf
part d.pdf
part e.pdf
VOL II Price Bid.pdf
GFRC.pdf
CORRIGENDUM
17ROOF TRUSS1.pdf
CORRIGENDUM
10FIRST FLOOR LEVEL SLAB and BEAMS1.pdf
CORRIGENDUM
1FOUNDATION and COLUMNS.pdf
CORRIGENDUM
Roof and pulmbing diagaram.pdf
CORRIGENDUM
Second-third floor Plumbing.pdf
CORRIGENDUM
Ground-first floor Plumbing.pdf
CORRIGENDUM
under ground water tank for fire and water.pdf
CORRIGENDUM
6. AMC Building HVAC layout_22.02.2026.pdf
CORRIGENDUM
5. AMC Building HVAC layout_22.02.2026-R4-Model.pdf
CORRIGENDUM
Second -third HVAC.pdf
CORRIGENDUM
Gfround -first HVAC.pdf
CORRIGENDUM
NK Fire4.pdf
CORRIGENDUM
NK Fire3.pdf
CORRIGENDUM
NK Fire 2.pdf
CORRIGENDUM
NK Fire1.pdf
CORRIGENDUM
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .