| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹34.8 LAccepted-AOC RAJKOT ROAD AIR FORCE STATION HALWARA 141106 PUNJAB | HALWARA | LUDHIANA | PUNJAB | 141106 | L1 | Accepted-AOC Being lowest | |
| 2 | L2₹42.3 L+₹6.8 L (19.0%)Rejected-Finance | L2 | Rejected-Finance Other than lowest |
Tender Value
₹35.8 L
EMD Value
₹71,500
Closing Date
7 Jan 2023, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (AF) Halwara
GE (AF) Halwara
PROVN OF CERTAIN SANCTIONED WORKS AT AF STN HALWARA
2022_MES_568017_1
GE/HAL-57/2022-23
Open Tender
Civil Works
Item Rate
183 days
GE (AF) Halwara
MES ENLISTED CONTRACTORS CLASS D CATEGORY a(i) and b(i)
8 documents required · 8 mandatory
₹500
Yes
GE (AF) Halwara
₹71,500
Yes
18 Jan 2023
8 Dec 2022
9 Jan 2023
8 Dec 2022
7 Jan 2023
23 Dec 2022
Amount
Demolition of brick work built in cement mortar including all quoins, arches, pillars etc complete all as specified
M&L for bircks works with sub class 'B' bricks straight or curved on plan exc 6m mean radious, built in cement mortar 1:6 complete all as specified and directed.
Taking down cement plaster of any description on brick or concrete surfaces etc including raking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed.
M&L for 12 mm thick rendering on brick work or concrete surfaces in cement mortar 1:6, finsihed the surfaces even and smooth without using extra complete all as specified and directed.
M&L for preparing new plastered surface of wall and applying two coats of distemper oil emulsion over a coat of wall putty complete all as specified & directed by Engineer-in- charge
Dismantling of wall and ceiling PVC boards of any thickness including cover fillets complete all as specified and directed.
Taking down chowkats or frames(without taking off shutters from the frame) area exc 1.5 Sqm but n.exc 4.0 Sqm each complete all as specified and directed..
All as per Sl item No 7 above but area not exc 1.50 Sqm each
S&F anodised aluminium powder coating frame for doors, windows ventilators including joining cleat for fixing etc.(Thickness of powder coating not less than 0.50 micron) complete all as specified and directed.
S&F powder coated aluminium door shutters, aluminium section weighing 0.55 kg/ m including necessary joining cleats, zing clips, ruber neoprene packing, handles 2 Nos in each door,tower bolt, hinges, anodised aluminium snap beading, screws etc (Thickness of powder coating not less than 0.50 micron) complete all as specified and directed.
S & F Powder coating aluminium window and ventilator shutters,side hung/fixed type without sash bars, aluminium section weighing 0.55 kg/ m including necessary joining cleats, zing clips, ruber neoprene packing, anodised aluminium snap beading screws anodised aluminium fittings such as peg stay, Tower bolt 150mm long 1 No. hinge type B-21 100 mm long 2 Nos, suitable handle 1 No (Thickness of powder coating not less than 0.50 micron) complete all as specified and directed.
S&F power coated Anodised aluminium grill of any pattern fixed to the window frame with screws , cutting the grill to proper opening size for fixing and operaton of handles complete as per requried and direction of Engineer-in-charge
S&F 4.8mm thick sheet glass ordinary quality and fixing in frame with glass putty or fixed with beads having area not exc 0.50 sqm in each pane complete all as specified
S&F 5.5mm thick sheet glass, ordinary quality and fixing in frame with glass putty or fixed with beads having in squares exc 0.5 sq. m each pane complete all as specified and directed.
S&F 0.9mm thick decorative laminate type 1, of surface finish, colour and pattern as approved, fixed with approved adhesive as per maker's instructions complete all as specified and directed.
S&F door closer Cast iron body hydraulically regulated, designation No. 3, universal type, suitable for door shutters of 851 to 1000 mm in width and of weight between 61 to 80 kg complete all as specified and directed.
Dismantling floor hearth or wall tiles including cement mortar bedding (but not backing), removing serviceable tiles to store and rubbish off the premises of MoD complete all as specified and directed.
M&L for rendering 10mm thick on fair faces of brick work or concrete surfaces in CM 1:4 rough finished surfaces to receive tiles complete all as specified and directed.
M&L for coloured glazed ceramic tiles 300x200x 6 to 7mm thick in vertical surfaces etc set and jointed in neat cement slurry and pointed in white or coloured cement to match complete all as specified and directed..
S&F Elegant tile of any color for false ceiling made of perforated Cement Fibre composite 595x595/295x1195/595x1195x5mm with square edge density 1050kg/m3 covered with absorbtive microfiber coating on the front side and Acoustics fibre on the back side,water resistance, fire resistant, absorption coffecient upto upto 0.89 at 160 Hz tested as per ISO 354. The tiles are anti sag and are to be installed on T24 grid system of 0.6mm thick , Main 'T' length minimum 3000mm, web minimum 35mm to be placed at 600mm centre to centre and secondary cross 'T' of length 600mm, web minimum 35 mm, inter locked, Wire Support for Main T to be taken at every 1200mm length wise and 600mm width wise,witth a backing of 50mm 1000 GSM thick absorbwool tested as per Fire Retardant IS 15061-2002 for excellent results complete all as specified and directed. Make - Himalayan Accoustic or equivalent as approved by GE. Note: Rate to be quoted by contractor includes all framework item and other connecting items.
S&F cement fibre elegant wood tile of any color 600x600/600x1200 x5mm with square edge density 1050kg/m3 covered with absorbtive microfiber coating on one side and accoustic fibre on other side, thus making it water resistance, fire resistance at 160hz tested as per ISo 354 and accousticaly absorptive . The tiles are anti sag and are to be installed with Aluminium H profile directly installed on walls complete all as specified and directed.Make - Himalayan Accoustic or equivalent as approved by GE. Note: Rate to be quoted by contractor includes all framework item and other connecting items.
S&F water tanks Rotational moulded polythylene water storage tank of capacity 750 ltrs (Cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part-I including dismantling of exisitng water tank complete all as spcified as as directed.
S&F 20 mm ball brass valves, high pressure, with polythene float and flynut complete, screwed for iron pipe or brass ferrule and fixed complete all as spcified as as directed.
M&L for preparation of old treated surfaces of any description over 10cm width or girth not otherwise described and applying two coats of Acrylic Exterior emulsion paint over a coat of primer in camouflage pattern using minimum 3 or 4 different approved tint/ colour as approved by GE complete all as specified.
M&L for rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces, mixed with water proofing compound @ 3% by weight of cement and finished even and smooth without using extra cement complete all as spcified as as directed.
M&L for preparation of new plaster surfaces of wall and applying two coats of synthetic enamel paint over a coat of primer in camouflage pattern, using minimum 3 different approved tint/ colour as approved by GE complete all as specified.
M&L for rendering 5mm thick on ceiling surfaces in CM 1:3 finished surfaces even and smooth without using extra cement complete all as spcified as as directed.
M&L for preparation of new plastered surfaces of ceiling and applying three coats of white wash complete all as specified and as directed.
Surface excavation not exceeding 30 cm deep and averaging 15 cm deep and getting out in soft/loose soil, complete all as specified and directed.
Excavation in post holes (or similar holes ) each n.exc 0.50 Cum, and getting out, returning filing in and ramming earth with broken rubble mixed with earth around in layers n.exc 25cm, watering etc and removing surplus soil n.exc 50m and making good surface in loose/soft soil complete all as specified and directed.
M&L for hard core of broken stone of gauge n. exc 63 mm, deposited, spread and levelled in layers not exc 15 cm thick, watered and rammed to true surface complete all as specified.
M&L for 75mm thick cement concrete 1:2:4 type B-2 (using 40mm graded aggregate) as in sub base or similar work complete all as spcified as as directed.
M&L for 100mm thick cement concrete 1:4:8 type D-2 (using 40mm graded aggregate) as in sub base below pavings, floor, path etc or similar work complete all as spcified as as directed.
S&F mild steel rolled section as in roof trusses (framed), purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Fe-290 (Gde E-165) complete all as specified and as directed
S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixing with self taping screws complete all as specified and as directed
M&L for machine pressed precast concrete interlocking paver blocks 60 mm thickness, M-35 Grade with grey cement and pigment, any shape and size confirming to IS 15658-2006 complete all as specified and directed.
M&L for machine pressed precast concrete interlocking paver blocks 80 mm thickness, M-40 Grade with grey cement and pigment, any shape and size confirming to IS 15658-2006 complete all as specified and directed.
M&L for Sand filling under floors or in foundations including watering and consolidation complete all as specified and directed.
M&L for preparation of new steel surfaces over 10cm width or girth and applying two coats of synthetic enamel paint over one coat of red oxide primer complete all as specified and as directed.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregates) as in kerbs, copings including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
Removing excavated material (soil) not exc 50m and depositing where directed at a level not exc 1.5m above the starting point complete all as specified and directed.
All as per Sl item No 43 above but area exceeding 2.00 Sqm each.
M&L for preparation of new plastered surfaces on wall and applying two coats of white wash etc complete all as specified and directed.
Preparation of new plaster surfaces of wall and applying two coats of acrylic exterior emulsion paint over a coat of primer in camouflage pattern, using minimum 3 different approved tint/ colour as approved by GE complete all as specified.
Taking down aluminium / copper point wiring with surface/ concealed stove enamelled steel/ PVC conduit or wooden batten ( light, fan, socket, or power ) including sunk in cast iron / pressed steel terminal boxes such as switches, ceiling roses, lamp holders, sockets, regulators, call bell, light fitting any sketch etc and making good disturbed surfaces of walls, floors etc complete.
M & L for concealed Point wiring for light with PVC insulated unsheathed FRLS two run of 1.5 Sqmm multi stranded copper conductor cable 1100 volts grade & one run of 1.5 Sq mm multi stranded copper conductor cable as continuous earth wire drawn in PVC conduit not less than 19/20 mm dia with all fittings shunk in MS Pressed steel terminal boxessuitable depth and 1.6mm thick (duly painted with two coat of anticorrosive paint outsite and Aluminium paint inside) with top cover 2.8 mm thick Hylem sheet cover for mounting of switches/sockets and fan regulators etc complete all as specified. Note:- Cost of cutting of chases wherever required in walls/ floors is deemed to be included in the unit rate of point wiring.
All as per item No. 48 above but with ceiling/wall Fan, one point controlled by one switch on the same board.
All as per item No. 48 above but with Exhaust Fan point, one point controlled by one switch on the same board.
All as per item No. 48 above but with socket outlet 5 Amps controlled by one switch on the same board.
All as per item No. 48 above but with One socket outlet 5 Amps controlled by one switch on independent board.
All as per item No. 48 above but with 4.0 sqmm for one 15 Amps socket outlet on independent board and 2.5 sqmm PVC insulated multisranded copper conductor cable as continuous earth wire complete.
S&F Switch piano type one way 5 amps 230 volts complete.
S&F Socket outlet 5 pin 5 Amps flush type complete.
S&F Switch piano flush button single pole one way 15 amps 230 volts complete.
S&F Socket out let 2 in 1, 6 pin, 5 and 15 amps multi purpose flush type, 230 volts.
S&F electronic fan regulator step type, 20V flush type on the existing phenolic laminated sheet etc.
S&F ceiling rose surface bakelite 3 terminals.
S&F Lamp holder PVC/ Polycarbonate insulated body with back plate for angle/batten fittings complete.
S&F LED lamp pin type 9 watt light complete all as specified.
S&F LED light fitting, 20 W, 4 ft long 230V, Wall mounted LED batten, extruded aluminium heat sink provided for efficient heat dissipation & integrated electronic driver complete with all accessories internally pre-wired.and including connecting up with twin core twisted flexible copper conductor cable with suitable size as specified as in replacement complete all as specified.
All as per item No 62 above but LED light fitting 2 Feet long 10 Watt LED Batten light for mirror and as wall light application complete
S&F recess mounting LED slim ceiling light with extruded aluminium housing and milky diffuser with 36W, 2'x2' (600x600x11mm) LED slim panel complete all as specified and directed.
S&F building security light fitting 35 W LED New generation Energy Saving & Environment friendly long life versatile pressure die-cast aluminium IP-66 roadway luminars with high power LEDs as light source and electronic drive including fixing arrangment on wall with clamps, nuts bolts, washers complete all as specified and directed.
S&F security light mounting bracket, GI pipe 40mm dia medium grade for mounting bracket bent to shape upto 1.50 meter length and fixing arrangement with two Nos of MS clamps set, nut, bolts, washers, and applying two coats of aluminium paints over one coat of Zinc oxide primer complete all as directed.
M&L for Sub main wiring with two single core PVC insulated cable of size 2 X 6 Sqmm + 1 X 6.0 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc. complete all as specified and directed.
S&F sheet metal enclosure MCB SPN distribution board, 8 way, Double door with IP-43 protection single phase 230 volts, including suitable size copper bus bar and neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match with existing specification complete all as specified and directed.
Supply and fix 'B' series MCB SPN 63 amps, 230 volts, 50Hz.
Supply and fix 'B' series MCB SPN 40 amps, 230 volts, 50Hz.
Supply and fix 'B' series MCB SP 6 to 32 amps, 230 volts, 50Hz.
Taking down carefully existing ceiling fan and Exhaust fan any size/ sweep for depositing to MES Yard, recollecting the fans for re-hanging the same after complete rewiring including transport and conneting the fan with 2 core flexible copper cable 23/0.0076 of required length connecting with ceiling rose complete all as directed.
S&F Loadline Vertical TPN DB prewired distribution board doble door, 6 way TPN-DPX 12-125, one No MCCB 125 Amps as incomer and SPN/SP MCBs 32 Amp for outgoing as site requared, double door type sheet metal enclosure 415V with 125 Amps rated standard busbar of suitable size plate and common neutral link without MCBs with blank plate suitable complete all as specified and as directed.
M&L for 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 25 Sqmm nominal cross section 3.5 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers testing and commissioning complete all as specified including taking out existing unserviceable cable from trenches, floor, ducts, poles or roads complete all as directed (Earth work shall be measured and paid separately).
S&F sheet metal enclosure MCB SPN distribution board, 8 way, Double door with IP-43 protection single phase 230 volts, including suitable size copper bus bar and neutral link fixed flush concealed in wall including taking out old DB's and chases wall for fixing DB and making good distributed wall/surfaces to match with existing specification.
All as per Sl item No 75 above but 2 way for L2 switch
Supply, installation, fixing, testing and commissioning AC Split type, intellisense inverter technology compressor, five star energy saving unit, single phase, cooling capacity 1.5 TR, including Remote Control unit, Plasma filter for better indoor air quality with minimum 5 star rating electric driven and split AC copper condensing unit (outdoor unit) fixed on suitable size perforated angle iron frame for mounting condensing units as required and evaporator grouted in side room at suitable height with provision of outlet PVC pipe for draining out condensed water up to floor level and gas connection by soldering or brazing including extra copper pipe duly insulated by insulated material & filling of gas where as required and testing after installation complete all as specified and directed.
S&F voltage stabilizer 5 KVA capacity (suitable for upto 2 Ton AC) automatic operation single phase, Working range of the Inverter AC (after connecting the stabilizer): 160-280 V, Microcontrolled operation, Smart output voltage correction, Fail safe circuit design; Low & High Voltage cut off; Initial Time Delay System; Sharp voltage control (SVC), Built in thermal overload protection, accuracy of +_ 2.5% with digital display including fix with wall/ floor complete all as specified and directed.
S&F sheet metal enclosure with metal clad socket & plug top with MCB single pole neutral 32 Amps complete all as specified and directed.
S&F electric Water heater storage type steel body with copper inner tank and heating element up to 2 KW capacity 35 Litre , BEE 5 Star rated complete with all accessories such as saftey valves , thermostate , NRV, connection pipe etc. complete all as specified and directed.
S&F 15mm dia bore steel water tubing medium grade galvanised with all fittings fixed to the wall or laid in floor or on ceiling complete all as specified and directed.
S&F 15mm dia Gun metal globe or gate valves with iron wheel head screwed both ends for iron pipe and fixed complete all as specified and directed.
S&F 300mm sweep exhaust fan steel body , AC single phase, 230 V with blades, frame and lauvers complete all as specified and directed.
M&L for making hole for exhaust/ventilation fan upto 380mm dia on wall, including making good to facings where required and plastering in cement mortar 1:4 to ends or edges, packing with wire mess with outer side of exhaust hole complete all as directed.
S&F 1200mm sweep ceiling fans with blades , down rods, electronic regulator, and accessories 230 V, minimum Air delivery 210 CFM with service value 6.00 BEE . Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
S&F 400mm sweep wall fan, swing, 230 volts, single phase, oscillating suitable for wall mounting with speed control regulator, mounting on wall complete all as directed.
S&F air termination single pointed copper rod 12mm dia and 300mm long complete all as specified and directed.
S&F test pont terminal block made out of gun metal or phosporus bronze size 75x75x25mm drilled and screwed including 3 nos 8mm dia 25mm long hex.head screw complete all as specified and directed..
S&F copper strip 32x6mm with saddles and fixing screws etc for roof conductors and down conductors above ground complete all as specified and directed.
M&L for ASHLOK'S Safe Earthing Electrode │ ASEEL 393 CP 250 │ Conceptualised & Developed using ASHLOK'S Pipe - In - Pipe Technology │ Designed & Manufactured using M.S Pipes │ Outer Dia is 76 mm with a wall thickness of 1.6 mm │ Inner Dia is 42 mm with a wall thickness of 2.6 mm │ Over all Length is 3000 mm │External Corrosion Protection : Coper Paleted (250+ microns) │ Internal Corrosion Protection : A groundbreaking corrosion resistant Crystalline Conductive Compund is filled and compacted in the cavity within the pipes to enhance the electrodes performance. │ Conforms to IS : 3043 - 1987 i.e., Code of Practice For Earthing │ (Tolerance : Dia: ± ı.o mm Wall │ Thickness: ± 0.2 mm │ Length: ± 20 mm). BARON'S Back Fill Compound(s) │CONDUCTOLITE │Conceptualised & Developed by BARON's R & D Centre │ Manufactured using Eco - Friendly minerals │Carbon based, high conductive material │Resistivity : < 0.5 ohm-metre (In dry conditions) │Resistivity is not moisture dependant │Ph Value : 6.5 - 8.0 │Electronic & Ionic conduction │Less susceptible to shrinkage │Maintenance Free │Excellent bonding properties │Enhances electrode size │It helps to improve the conductivity of the soil to aid in faster current dissipation while at the same time having hygroscpic & corrosion resistive properties. │Packing Size : 25 kilograms │ Recommended for harsh conditions incl Poly Plastic Eartpit Chamber Cover Heavy Duty (8 ton Capacity) complete all as specified and as directed.
M&L for earthing complete with Galvanised Iron earth plate electrode 60x60cmx6mm thick burried directly in ground ( earth pit not less than 2.25 Mtr deep below ground level ) with top edge of the plate not less than 1.5 Mtr below normal ground level, connected to galvanised iron earth lead wire 4mm dia by means of bolts, nuts, check nuts and washers of GI or steel all as shown in electrical plate No. 5 of SSR Part-I 1991 connected to earthing test point/transformer/panel all as specified or indicated and testing on completion as directed by the Engineer-in-Charge including necessary excavation & earth work in any type of soil, funnel, PCC chamber ( 1 : 3 : 6) type C1, PVC pit cover with frame, charcol, salt including provision of earth lead protected by 15mm dia light grade GI pipe and 20mm dia medium grade GI Pipe for watering complete all as directed. Note :- (i) Item of earthing includes cost of 15mm bore medium grade GI protection Pipe and 7.5 Meters long earth strip/lead upto test point. (ii) On testing after completion of earthing if the desired earth resistance is not obtated earthning will be re-done by the contractor at his own risk and cost to the entire satisfaction of Engr-in Charge.
M&L for Sub main wiring drawn with surface PVC conduit/ PVC casing & caping, PVCwith PVC insulated cable of size 2 X 10.0 Sqmm + 1 X 10 Sqmm earth wire multi stranded copper conductor drawing into and including heavy duty 25mm dia surface PVC conduit and continuous earth wire complete and making good disturbed surfaces of wall/ floor etc.
S&F MS looping boxes ( Bus bar chamber box) of LT, 415 volts 32A, 4 way TPN aluminium bus bars complete fixed on wall with and including nut , bolts and wshers including providing the electricial connection for incoing/outgoing cable throuhg proper lugs/thimbles complate all as specified and directed.
M&L for 1100 volt grade heavy duty XLPE cable with PVC insulated aluminium conductor served with inner sheathing of PVC tape armoured with galvanized steel strip or wire and overall PVC sheathed of size 10 Sqmm nominal cross section 4 core laid in trenches, fixed to pole or passing through pipes including all necessary clamps, nuts, bolts washers testing and commissioning complete all as specified
S&F 300mm sweep copper winding ventilation fan made of studry Engineering plastic complete with louver shutters, voltage 230 vlts, 50 Hz, RPM 1200 complete all as specified and directed.
Excavation in trenches in soft or loose soil, not exceeding 1.5 metre deep and not exceeding 1.5 metre wide and getting out complete all as specified and directed. Notes : (i) Payment for excavation shall be made for one time in case the new cable is laid in the same trenches .
Returning, filling in trenches including spreading, leveling, watering and well ramming in layers not exc 25 cm thick in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil to a distance not exceeding 50 Mtr and depositing where directed at a level not exceeding 1.5 Mtr above the starting point complete all as specified and as directed.
M&L Brick protection with sub class "B" bricks (old size) laid dry, flat in trenches over cable with longest dimension perpendicular to the axis of the cable complete all as specified and directed specified .
Sand cushioning in trenches and well ramming in layers with 8 cm below and 15 cm above the cable with fine dry sand for cable protection and complete all as specified and directed. Note: 18 cm punned thickness shall be measured for payment purpose.
BEHL AND COMPANY
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .