Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹73.4 LAccepted-AOC H NO 54 8 DARMYANA MUHALLA DISTT MANDI 1750051 | MANDI | MANDI | HIMACHAL PRADESH | 175005 | ₹73.4 L | L1 | Accepted-AOC Quoted rates are lowest |
| 2 | L2₹76.9 L+₹3.5 L (4.77%)Rejected-Finance | ₹76.9 L+₹3.5 L (4.77%) | L2 | Rejected-Finance Quoted rates are higher |
| 3 | L3₹81.3 L+₹8.0 L (10.9%)Rejected-Finance GROUND FLOOR DOLFIN CONSTRUCTION KHEWAT NO 263 KHATAUNI NO 255 VPO TALYAHAR TEHSIL SADAR DISTT MANDI H P 175001 | MANDI | MANDI | HIMACHAL PRADESH | 175001 | ₹81.3 L+₹8.0 L (10.9%) | L3 | Rejected-Finance Quoted rates are higher |
| Sl No | Description | Qty | Unit | Mansih Kapoor L1 | Kartike Guleria L3 | CHHAJWA CONSTRUCTION CO L2 |
|---|---|---|---|---|---|---|
| 1.00 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 1,740 | kg | 120 ₹2,08,800 | 118 ₹2,05,320 | 115 ₹2,00,100 Lowest |
| 2.00 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete.
a) Electric resistance or induction butt welded tubes as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 18,000 | kg | 130 ₹23,40,000 | 145 ₹26,10,000 | 125 ₹22,50,000 Lowest |
| 3.00 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A, including jointing with seal ring
conforming to IS : 5382, leaving 10 mm gap for thermal expansion, (i)
Single socketed pipes.
a) 75 mm diameter as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 440 | metre | 150 ₹66,000 Lowest | 240 ₹1,05,600 | 350 ₹1,54,000 |
| 4.00 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
a) Coupler
i) 75 mm diameter | 100 | each | 120 ₹12,000 Lowest | 125 ₹12,500 | 200 ₹20,000 |
| 5.00 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS: 13592 Type A, including jointing with seal ring conforming to IS : 5382,
leaving 10 mm gap for thermal expansion.
a) Bend 87.5°
i) 75 mm diameter as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 125 | each | 120 ₹15,000 Lowest | 125 ₹15,625 | 250 ₹31,250 |
| 6.00 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50 mm hard wood plugs, screwed with M.S. screws of required length, including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete.
a) 75 mm diameter as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 100 | each | 25 ₹2,500 Lowest | 250 ₹25,000 | 250 ₹25,000 |
| 7.00 | Providing & fixing UV stabilised fiberglass reinforced plastic sheet roofingup to any pitch, including fixing with polymer coated ‘J’ or ‘L’ hooks, bolts& nuts 8 mm dia. G.I plain/bitumen washers complete but excluding thecost of purlins, rafters, trusses etc. The sheets shall be manufacturedout of 2400 TEX panel rovigs incorporating minimum 0.3% ultra-violetstabiliser in resin system under approximately 2400 psi and hot cured.They shall be of uniform pigmentation and thickness without air pocketsand shall conform to IS 10192 and IS 12866.The sheets shall be opaqueor translucent, clear or pigmented, textured or smooth as specified.
a) 2 mm thick flat as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 473 | Sqm | 1,200 ₹5,67,600 | 1,150 ₹5,43,950 Lowest | 2,000 ₹9,46,000 |
| 8.00 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 890 | Sqm | 895 ₹7,96,550 | 880 ₹7,83,200 | 675 ₹6,00,750 Lowest |
| 9.00 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
a) Flashings/ Aprons.(Upto 600 mm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 340 | metre | 650 ₹2,21,000 | 500 ₹1,70,000 Lowest | 700 ₹2,38,000 |
| 10.00 | Providing and fixing precoated galvanised steel sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :
a) Barge board (Upto 300 mm) as per entire satisfaction and direction of Engineer-in-charge including carriage of material in all leads and lifts. | 340 | metre | 650 ₹2,21,000 | 500 ₹1,70,000 Lowest | 700 ₹2,38,000 |
Tender Value
₹93.3 L
EMD Value
₹1.9 L
Closing Date
17 Feb 2026, 6:00 pmClosed
Suprintending Engineer IIT Mandi Kamand
O/o Superintending Engineer, North Camps IIT Mandi Kamand Distt. Mandi HP-175075
Upgradation of facade for 9 nos faculty housing blocks (C12 C13 C15 C20 C22 C24 C31 C35) and structural up-gradation of faculty housing blocks C11 C12 C13 C14 C15 C16 C19 C20 C22 C23 C24 C25 C26 C28 C29 C30 C31 C32 C34 C35 C36 C-37) Academic blocks..
2026_IITMD_895618_1
IIT Mandi (CW)/SE-1889/2025 -26/3172-74 dated 22-01-2026
Open Tender
Civil Works
Item Rate
150 days
North Campus of IIT Mandi
Please refer to NIT
2 documents required · 2 mandatory
₹1,180
The Registrar IIT Mandi
₹1.9 L
28 Mar 2026
27 Jan 2026
19 Feb 2026
27 Jan 2026
17 Feb 2026
27 Jan 2026
27 Jan 2026 - 17 Feb 2026
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .