Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.2 LAccepted-AOC | L1 | Accepted-AOC Due to lowest. | |
| 2 | L2₹10.0 L+₹70,230 (7.59%)Rejected-Finance | L2 | Rejected-Finance Due to 2nd lowest. | |
| 3 | L3₹10.3 L+₹1.0 L (11.2%)Rejected-Finance SADARPARA PURULIA 723101 | PURULIA | PURULIA | WEST BENGAL | 723101 | L3 | Rejected-Finance Due to 3rd lowest. | |
| 4 | L4₹10.9 L+₹1.7 L (18.2%)Rejected-Finance 448 MUZAFFAR AHMED STREET KOLKATA 700 016 | KOLKATA | KOLKATA | WEST BENGAL | 700016 | L4 | Rejected-Finance Due to 4th lowest. |
| Sl No | Description | Qty | Unit | MODERN ELECTRICALS L2 | DEB SHANKAR LAYEK L1 | RASH ELECTRICAL WORKS L4 | SAIBAL SARKAR L3 |
|---|---|---|---|---|---|---|---|
| 1.00 | Dismantle the old damage electrical items like fan,light,wire etc and return to sectional store. | 1 | Job | 5,000 ₹5,000 | 2,283 ₹2,283 Lowest | 4,901 ₹4,901 | 2,400 ₹2,400 |
| 2.00 | Supplying and fixing Changeover switch with Sheet Steel enclosure on angle iron frame on wall with100A(HPL/Havells)(D1/2b)
nuts bolts etc | 1 | Each | 12,000 ₹12,000 | 11,550 ₹11,550 | 4,554 ₹4,554 Lowest | 11,800 ₹11,800 |
| 3.00 | Supplying and fixing 415V, TPN SFU with sheetsteel enclosure on flat iron/angle iron frame on wall
with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.100A(L&T,Havells)(D3/4a) | 1 | Each | 10,000 ₹10,000 | 7,800 ₹7,800 | 5,967 ₹5,967 Lowest | 8,000 ₹8,000 |
| 4.00 | Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed
in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.min 8 wayLegrand (Enclosure (607717) or schneider)(D10/14) | 1 | Each | 4,500 ₹4,500 | 5,100 ₹5,100 | 4,012 ₹4,012 Lowest | 5,300 ₹5,300 |
| 5.00 | Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after
cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of
copper wire and neutral link & provision for earthing attachment.2+12way(legrand/schneider)(D9/13) | 3 | Each | 2,500 ₹7,500 | 2,150 ₹6,450 Lowest | 3,543 ₹10,629 | 22,000 ₹66,000 |
| 6.00 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.FP 100A(Legrand/Siemens)(D5/6) | 1 | Each | 1,200 ₹1,200 | 1,150 ₹1,150 Lowest | 3,209 ₹3,209 | 1,200 ₹1,200 |
| 7.00 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.DP 40A(Legrand/Siemens)(D5/6) | 3 | Each | 500 ₹1,500 | 430 ₹1,290 Lowest | 2,792 ₹8,376 | 490 ₹1,470 |
| 8.00 | Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.DP 20A(Legrand/Siemens)(NS) | 10 | Each | 750 ₹7,500 | 400 ₹4,000 Lowest | 2,512 ₹25,120 | 450 ₹4,500 |
| 9.00 | Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface]Average run 10 mtr(E11/2) | 65 | Points | 1,000 ₹65,000 Lowest | 1,170 ₹76,050 | 1,349 ₹87,685 | 1,200 ₹78,000 |
| 9.01 | on board(E12/6) | 10 | Points | 100 ₹1,000 | 83 ₹830 Lowest | 96 ₹960 | 85 ₹850 |
Tender Value
Refer Docs
EMD Value
₹18,553
Closing Date
28 Nov 2025, 6:00 pmClosed
EE_PED_PWD
RANCHI ROAD, PURULIA
Repair and Renovation of Electrical Installation work at the Bungalow of the Chief Medical Officer of Health Purulia in the District of Purulia
2025_WBPWD_951515_1
WBPWD/EE/PED/NIQ14 /2025-2026
Open Tender
ELECTRICAL WORKS ORG
Item Rate
30 days
PURULIA
Please refer Tender documents.
4 documents required · 4 mandatory
₹18,553
29 Sept 2026
18 Nov 2025
1 Dec 2025
22 Nov 2025
28 Nov 2025
22 Nov 2025
Amount
Dismantle the old damage electrical items like fan,light,wire etc and return to sectional store.
Supplying and fixing Changeover switch with Sheet Steel enclosure on angle iron frame on wall with100A(HPL/Havells)(D1/2b) nuts bolts etc
Supplying and fixing 415V, TPN SFU with sheetsteel enclosure on flat iron/angle iron frame on wall with nuts bolts etc incl. S & F 3 nos. DIN type HRC fuse as per rating.100A(L&T,Havells)(D3/4a)
Supplying and fixing double door Horizontal TPN MCB Distribution board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.min 8 wayLegrand (Enclosure (607717) or schneider)(D10/14)
Supplying and fixing double-door SPN MCB Distribution Board with IP-42/43 protection, concealed in wall after cutting the wall & mending good the damages to original finish incl. Inter connection with suitable size of copper wire and neutral link & provision for earthing attachment.2+12way(legrand/schneider)(D9/13)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.FP 100A(Legrand/Siemens)(D5/6)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.DP 40A(Legrand/Siemens)(D5/6)
Supplying and fixing 240/415 V MCB Isolator on din rail of existing DBs and necessary connection.DP 20A(Legrand/Siemens)(NS)
Distribution wiring in 1.1 KV grade 2x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in suitable size PVC casing-capping (Precision make) with 1x22/0.3 (1.5 sqmm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, incl. necy. PVC clips, fittings etc. to light/fan/call bell point with piano key type switch (Anchor make) fixed on sheet steel fabricated switch board with Perspex/bakelite top cover on wall incl. necy. connections and making earthing attachment and mending good damages to building works. [PVC casing-capping and Switch board both on surface]Average run 10 mtr(E11/2)
on board(E12/6)
Supplying and fixing 240/415 V MCB of Breaking capacity 10kA & C characteristics on din rail of existing DBs and necessary connection.6-32 A, SP, [Make:- L & T [[D-6/7]
Wiring in 1.1 KV grade single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) of following sizes in 25mm PVC casing-capping (Precision make) incl. necy. PVC clips, fittings etc.(E11/1)
2 x 22/0.3 (1.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
2 x 36/0.3 (2.5 sqmm) + 1 x 22/0.3 (1.5 sqmm)
2x56/0.3 (4 sqmm) + 1x36/0.3 (2.5 sqmm) as ECC
Distribution wiring in 1.1 KV single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) in 20mm size PVC rigid conduit 'FR' (Precision make) incl. necy.fittings as required
2 x 84/0.3 (6 sqmm) + 1 x 56/0.3 (4 sqmm) ECC.[E-14/1(a)(iv)] PDB to SPNDB
Supply of 4/3.5/2 Core XLPE / PVC Insulated & Sheathed Armoured Al. Conductor cables for working Voltage up to 1100 Volts of following sizes [Make Nicco /Polycab/ Fort Gloster ] ---4 Core 16 sqmm( Main switch to TPNDB)
2 core 10 sqmm(street light)
Laying of cable upto 3/4 core 25 sqmm on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot Dip) Wire, making holes etc. as necy. mending good damages and painting [F-1/2(b)]
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of XLPE/PVC armoured cables as below
4core 16sq mm(F4/7c)
2 core 10sq mm(F4/7a)
Finishing the end of following XLPE/PVC armoured cables by crimping method incl. supplying and fixing solderless socket (Dowels make), tapes, anticorrosive paste & jointing materials
2 core 10sq mm(F5/8b)
4 core 16 sq mm(F5/8b)
Finishing of the PVC insulated wire ends by socketting with pin/ ring type copper sockets and insulated tapes etc., including supplying sockets, tapes.
2.5 sq mm(F5/9i)
4 sq mm(F5/9ii)
6 sq mm(F5/9iii)
Supply of 4' 22W T8 LED tube light fittings with complete set including LED tube. (Make:- Philips TMC 502 1xT-LED 22W , including MAS LED tube 1200mm 18W 865 T 8 I 2100lm/ Bajaj/ Crompton)
Supply of twin 4' 22W T8 LED tube light fittings with complete set including LED tube. (Make:- Philips TMC 502 2 xT-LED 22W , including MAS LED tube 1200mm 18W 865 T 8 I 2100lm/ Bajaj/ Crompton)
Supply of 56"(1400mm) sweep A.C. ceiling fan complete with all accessories. (Make: Orient - New breeze / Crompton high speed)
Supply of 12'' 1370 r.p.m. sweep AC exhaust fan (EPC heavy duty/ Usha turbo LD DBB) and S& F louver with nuts and bolts.
Supply and fixing of 60watt LED Street Light incl all necy connection. (Make- Crompton, Cat No. BRP 032 LED 60 CW SLR GR PSU/Philips/Havells) .[NS]
Supply & fixing of Decorative Post top of luminaries for 360° indirect light with IP 65 protection. Resistant to impact and corrosion. Glare-free and better uniformity.[Make- Crompton, Cat No. LPTO-40-CDL-M] Or equivalent make of Bajaj/Havells.
Supply & fixing of GENREE Smooth Design Wood and PVC Wall Light Lamp (Brown and White)(Make-Crompton/philips/Magik or equivalent)
Fixing only outdoor / street light type fluorescent light fitting complete with all accessories to be fixed/projected from the wall of the building incl. making holes to building, S&F 40 mm dia GI pipe (ISI-Medium) 1.50 mts. average length, with GI socket at one end and thread at the other end & suitable bend to house the fitting & making necy. connections with S&F necy. length of 1.5 sqmm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall and painting. [C-3/18]
Fixing only single/twin fluorescent light fitting suspended 25 cm bellow the ceiling with 2 No. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S&F EI conduit, “L” type (125mmx125mm) 6mm thick and 25mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[C-2/17]
Fixing only single/twin fluorescent light fitting complete with all accessories directly on wall/ceiling by screws etc.C-2/14(a)
Extra for suspension exceeding 25 cm with S&F additional 2 no. 20 mm dia EI conduit (14 SWG) supports & necy. PVC insulated wire and painting etc. as required by 2x24/0.20 mm (1.5sqmm.) flexible copper wire of 1.10 mt. length.[C-2/16]
Fixing only ceiling fan complete with blades, canopy, fork, rubber bush etc. incl. S&F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2x1.5 sqmm flexible copper wire.C-3/21(a)
Supplying & Fixing MS fan clam of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting – (As per Drawing no. 475 of PWD Specification Book – May 1991)[D-14/29]
Supply & Fixing Socket type fan regulator (Step type) (Brand approved by EIC) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.[E-6/18(a)]
Earthing with 50 mm dia GI pipe 3.64 mm thick x 3.04 Mts. long and 1 x 4 SWG GI (Hot Dip) wire (4 Mts. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 Mts. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 Mts. below the ground level as below:TATA ISI medium GI PIPE(G1/2a)
Supply & Fixing 240 V, 25 A, Modular type starter (Brand approved by EIC) with 25A Modular switch type DP MCB (CCurve) and 4 Module GI Modular type switch board with 4 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(E19/17)
Supplying & Fixing GI Modular Switch Board of the following sizes complete with top cover plate flushed in wall for housing the board after cutting the brick wall incl. making earthing attachment, painting and mending good damages to building works 2 module (E17/2a)
Supply & Fixing 240 V, 16 A, 3 pin Modular type plug socket (Brand approved by EIC), without plug top and switch, on existing GI Modular type switch board with top cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc. [E-17/4(b)]
Supply & Fixing 240 V, 20A, plug socket with separate 20 A Piano key type switch (Brand approved by EIC) on sheet metal switch board embedded in wall incl. S & F 150x100x65mm MS (16SWG) switch board andbakelite/perspex top cover of 3mm thick by Brass screws after making housing for switch by cutting bakelite/perspex cover and making necessary connections as required.[E-6/22]
Supply & Fixing 240 V, 4 nos. 6 A, 3 pin Modular type plug socket with 4 nos. 6A Modular type switch (Brand approved by EIC), 16A Modular switch type MCB (C-Curve) and Indicator without plug top on 2 row 18 Module GI Modular type switch board with 2 row 18 Module top cover plate flushed in wall incl. S&F switch board and cover plate and making necy. connections with PVC Cu wire and earth continuity wire etc.(E18/12)
Erection of Single Steel tubular pole of length as given below with/without sole plate & Cap etc. in CC foundation (Proportion and dimension indicated below), having 600x600x150 mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mts. dia and 0.30 mts. above ground level including 3 mm thick net cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 Km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.(H-1,Item-a(1)) Upto 9.0 mtr size 0.6 X 0.6X1.70 mts
Supply of 09 mtr long ST pole (Model-410 SP-25).Overall length 09 mtrs & planting depth 1.5 mtrs.Length of section bottom-5 mtr,middle-2 mtr and top 2 mtr long out side thickness of section bottom 11 4. 3x3 .6 5 mm,middle-88 .9x 3. 25 mm and top 76 .1x 3. 25 mm with base plate as per direction of EIC.Approx weight of pole-78 Kg. (M-Calcutta Pole/Bansal(NS)
Painting of Steel Tubular Pole of lengths and no. of coats of paint, as given below with ready mixed paint/primer of approved make, and brand incl. preparation of surface by sand paper/emery paper, cleaning etc. for receiving fresh coat of paintUpto 9.0 mtr. long pole
1st coat of aluminium paint over 1 coat of RO priming(H2/4a)
2nd coat of aluminium paint over 1st coat(H2/4a)
Providing CC (6:3:1) muffing 450x450x600 mm in size or equivalent size of cylindrical muffing above ground level ,neatly cemented (3 mm thick)at the base pole(In lieu of CCmuffing) suitable for alkathene/polythene pipe as directed for street light wiring . Without loop box(I-1,item-13(a)
S & F GI Loop Box of size (10" x 8" x 4" ) including S & F 63A 4 stud copper connector -1 no and 10A MCB (C Curve,10KA) on Dim Rail channel-01 no including all necy connection & arrangements.(NS)
S & F GI Loop Box of size (6" x 8" x 4" ) including S & F 63A 2stud copper connector -1 no and 10A MCB (C Curve,10KA) on Dim Rail channel-01 no including all necy connection & arrangements.(NS)
S & F single arm of 1.5 mtr long GI pipe of 40 mm dia with 1ft long upto 4 " dia sleeve incuding necy painting ,whole and nut,bolt washers etc..(NS)
LED flood light (100W)made up of pressure die cast aluminium housing with toughened glass and high power LEDs and secondary lenses with IP66 protection.System efficiency min 110/LPW 10KV SPD included.(Make-Crompton, Cat No. TFS-507-150-57-60D-SL-GL-NSG/Philips or equivalent
Laying of one No. cable( 2cx10sq mm AL Armoured,Make-Havells,Glowster,Polycab)upto 35 sqmm in underground trench 460 mm wide x 760 mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per metre, including filling the space between the brick & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed(F2/1a)
MODERN ELECTRICALS (BID ID -7458497)
SAIBAL SARKAR (BID ID -7452211)
RASH ELECTRICAL WORKS (BID ID -7496302)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.09 MB
2911_ii.pdf
Tender Documents • 0.89 MB
BOQ_2278372.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .